HYDROGEN FAST FILLING TO A TYPE IV TANK DEVELOPED FOR MOTORCYCLES

Similar documents
EXPERIMENTAL STUDY OF THE THERMAL BEHAVIOUR OF HYDROGEN TANKS DURING HYDROGEN CYCLING

Influence of rounding corners on unsteady flow and heat transfer around a square cylinder

CFD Simulation and Experimental Validation of a Diaphragm Pressure Wave Generator

HYDROGEN TANK FILLING EXPERIMENTS AT THE JRC-IE GASTEF FACILITY

AIRFLOW GENERATION IN A TUNNEL USING A SACCARDO VENTILATION SYSTEM AGAINST THE BUOYANCY EFFECT PRODUCED BY A FIRE

A. M. Dalavi, Mahesh Jadhav, Yasin Shaikh, Avinash Patil (Department of Mechanical Engineering, Symbiosis Institute of Technology, India)

CFD SIMULATIONS OF GAS DISPERSION IN VENTILATED ROOMS

Single Phase Pressure Drop and Flow Distribution in Brazed Plate Heat Exchangers

Experimental Verification of Integrated Pressure Suppression Systems in Fusion Reactors at In-Vessel Loss-of -Coolant Events

Numerical and Experimental Investigations of Lift and Drag Performances of NACA 0015 Wind Turbine Airfoil

The Study on the Influence of Gust Wind on Vehicle Stability Chen Wang a, Haibo Huang b*, Shaofang Xu c

MODELING AND SIMULATION OF VALVE COEFFICIENTS AND CAVITATION CHARACTERISTICS IN A BALL VALVE

Influence of Ambient Temperature on Performance of a Joule-Thomson Refrigerator

Research and optimization of intake restrictor for Formula SAE car engine

MODELLING OF FUME EXTRACTORS C. R.

OPTIMIZATION OF INERT GAS FLOW INSIDE LASER POWDER BED FUSION CHAMBER WITH COMPUTATIONAL FLUID DYNAMICS. Abstract. Introduction

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

INTERACTION BETWEEN WIND-DRIVEN AND BUOYANCY-DRIVEN NATURAL VENTILATION Bo Wang, Foster and Partners, London, UK

Experimental Determination of Temperature and Pressure Profile of Oil Film of Elliptical Journal Bearing

ANALYSIS OF HEAT TRANSFER THROUGH EXTERNAL FINS USING CFD TOOL

Special edition paper

A computational study on structural barrier to vertical spread of window spill plume along building exterior façade under external wind

Bio-Effluents Tracing in Ventilated Aircraft Cabins

Experimental Study of Hydrogen Release Accidents in a Vehicle Garage

A Numerical Study of the Performance of a Heat Exchanger for a Miniature Joule-Thomson Refrigerator

Predicting the Suction Gas Superheating in Reciprocating Compressors

Numerical Investigation of Air Bubbles Evolution and Coalescence from Submerged Orifices Based on OpenFOAM

Injector Dynamics Assumptions and their Impact on Predicting Cavitation and Performance

DYNAMIC CRUSH TEST ON HYDROGEN PRESSURIZED CYLINDER

EXPERIMENTAL STUDY OF HOT INERT GAS JET IGNITION OF HYDROGEN-OXYGEN MIXTURE

Study on Fire Plume in Large Spaces Using Ground Heating

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

OPTIMIZATION OF RECUPERATER FIN GEOMETRY FOR MICRO GAS TURBINE

ZIN Technologies PHi Engineering Support. PHi-RPT CFD Analysis of Large Bubble Mixing. June 26, 2006

Modeling and Investigation of Change in Working Parameters on the Performance of the Vortex Tube with CFD Analysis

Thermodynamic Study of Compartment Venting

THE STUDY ON THE INTERNAL TEMPERATURE CHANGE OF TYPE 3 AND TYPE 4 COMPOSITE CYLINDER DURING FILLING

Experimental Characterization and Modeling of Helium Dispersion in a ¼-Scale Two-Car Residential Garage

The effect of wind speed on the performance of a split chimney

Measurement and simulation of the flow field around a triangular lattice meteorological mast

Effect of Inlet Clearance Gap on the Performance of an Industrial Centrifugal Blower with Parallel Wall Volute

Wind Flow Model of Area Surrounding the Case Western Reserve University Wind Turbine

Effect of Diameter on the Aerodynamics of Sepaktakraw Balls, A Computational Study

The Usage of Propeller Tunnels For Higher Efficiency and Lower Vibration. M. Burak Şamşul

A Research on the Airflow Efficiency Analysis according to the Variation of the Geometry Tolerance of the Sirocco Fan Cut-off for Air Purifier

OPTIMIZATION OF SINGLE STAGE AXIAL FLOW COMPRESSOR FOR DIFFERENT ROTATIONAL SPEED USING CFD

Numerical Simulations of a Train of Air Bubbles Rising Through Stagnant Water

Numerical simulation and analysis of aerodynamic drag on a subsonic train in evacuated tube transportation

Aerodynamic Performance of Trains with Different Longitudinal Section Lines under Crosswind

Influencing Factors Study of the Variable Speed Scroll Compressor with EVI Technology

Available online at ScienceDirect. Physics Procedia 67 (2015 )

Performance Analysis of Centrifugal Compressor under Multiple Working Conditions Based on Time-weighted Average

CFD Study of Solid Wind Tunnel Wall Effects on Wing Characteristics

Simulations of hydrogen releases from high pressure storage systems

1 SE/P-02. Experimental and Analytical Studies on Thermal-Hydraulic Performance of a Vacuum Vessel Pressure Suppression System in ITER

Inlet Swirl on Turbocharger Compressor Performance

Pressure coefficient on flat roofs of rectangular buildings

Wind tunnel effects on wingtip vortices

Flow transients in multiphase pipelines

Research on Small Wind Power System Based on H-type Vertical Wind Turbine Rong-Qiang GUAN a, Jing YU b

Fire test of ventilated and unventilated wooden façades

HYDROGEN RISK ANALYSIS FOR A GENERIC NUCLEAR CONTAINMENT VENTILATION SYSTEM

Finite Element Analysis on Trapezoidal Tank to Suppress Sloshing Effect

An Experimental Performance Study of Vortex Tube Refrigeration System

Purdue e-pubs. Purdue University. Stephan Lehr Technische Universitaet Dresden. Follow this and additional works at:

CFD Analysis and Experiment Study of the Rotary Two-Stage Inverter Compressor with Vapor Injection

A COMPARATIVE STUDY OF MIX FLOW PUMP IMPELLER CFD ANALYSIS AND EXPERIMENTAL DATA OF SUBMERSIBLE PUMP

NUMERICAL SIMULATION OF STATIC INTERFERENCE EFFECTS FOR SINGLE BUILDINGS GROUP

Study on the Influencing Factors of Gas Mixing Length in Nitrogen Displacement of Gas Pipeline Kun Huang 1,a Yan Xian 2,b Kunrong Shen 3,c

Gas Vapor Injection on Refrigerant Cycle Using Piston Technology

Available online at ScienceDirect

Session on applications: HRS - refuelling. P. Moretto

Aerodynamic Measures for the Vortex-induced Vibration of π-shape Composite Girder in Cable-stayed Bridge

SPONTANEOUS IGNITION OF PRESSURIZED HYDROGEN RELEASE

Australian Journal of Basic and Applied Sciences. Pressure Distribution of Fluid Flow through Triangular and Square Cylinders

THEORETICAL EVALUATION OF FLOW THROUGH CENTRIFUGAL COMPRESSOR STAGE

OPTIMIZING THE LENGTH OF AIR SUPPLY DUCT IN CROSS CONNECTIONS OF GOTTHARD BASE TUNNEL. Rehan Yousaf 1, Oliver Scherer 1

Control of surge and pitch motions of a rectangular floating body using internal sloshing phenomena. Minho Ha and *Cheolung Cheong 1)

Direct Numerical Simulation on Hydrogen Fuel Jetting from High Pressure Tank

Numerical simulation on down-hole cone bit seals

CFD Analysis ofwind Turbine Airfoil at Various Angles of Attack

POSTER PAPER PROCEEDINGS

Aerodynamic Performance of 160km Box Car

MATHEMATICAL MODELING OF PERFORMANCE OF A LIQUD PISTON COMPRESSOR

Reflux Condensation with Various Non-Condensable Gases

Linear Compressor Discharge Manifold Design For High Thermal Efficiency

A Numerical Simulation of Fluid-Structure Interaction for Refrigerator Compressors Suction and Exhaust System Performance Analysis

SIMULATIONS OF HYDROGEN RELEASES FROM A STORAGE TANKS: DISPERSION AND CONSEQUENCES OF IGNITION

Effect of Co-Flow Jet over an Airfoil: Numerical Approach

Investigation of Suction Process of Scroll Compressors

Numerical Simulation for the Internal Flow Analysis of the Linear Compressor with Improved Muffler

AIRFOIL PROFILE OPTIMIZATION OF AN AIR SUCTION EQUIPMENT WITH AN AIR DUCT

Domain Decomposition Method for 3-Dimensional Simulation of the Piston Cylinder Section of a Hermetic Reciprocating Compressor

Characteristics of Decompression Tank Internally Pressurized With Water Using OpenFOAM Syamsuri 1, a

Influence of Ventilation Tube Rupture from Fires on Gas Distribution in Tunnel

The Mechanism Study of Vortex Tools Drainage Gas Recovery of Gas Well

Centre for Offshore Renewable Energy Engineering, School of Energy, Environment and Agrifood, Cranfield University, Cranfield, MK43 0AL, UK 2

EXPERIMENTAL STUDY ON HYDROGEN EXPLOSIONS IN A FULL-SCALE HYDROGEN FILLING STATION MODEL

Investigation on 3-D Wing of commercial Aeroplane with Aerofoil NACA 2415 Using CFD Fluent

WALL BOILING MODELING EXTENSION TOWARDS CRITICAL HEAT FLUX. ABSTRACT

Transcription:

HYDROGEN FAST FILLING TO A TYPE IV TANK DEVELOPED FOR MOTORCYCLES Yamada, E. 1, Hiraki, W. 2, and Muramatsu, H. 3 1 FC-EV Research Division, Japan Automobile Research Institute, 1328-23 Takaheta, Osaka, Shirosato, Ibaraki 311-4316, Japan, eyamada@jari.or.jp 2 FC-EV Research Division, Japan Automobile Research Institute, 1328-23 Takaheta, Osaka, Shirosato, Ibaraki 311-4316, Japan, whiraki@jari.or.jp 3 Suzuki Motor Corporation, 3 Takatsuka, Minami-ku, Hamamatsu, Shizuoka 432-8611, Japan, muramatsuh@hhq.suzuki.co.jp ABSTRACT Hydrogen is one of possible alternative energy sources to replace fossil fuels in transportation sector. Hydrogen fuel cell vehicles (FCVs) are expected to play an important role in the future. A tank to store compressed hydrogen is necessary for the FCVs due to the long-distance driving as well as that of conventional vehicles. It is also necessary that refueling the tank should be completed within a few minutes because of user convenience. In this study, a fast filling of high pressurized hydrogen is concerned for a Type IV tank which has been developed for motorcycles. Due to restrict the temperature rise up to 85 degrees Celsius for fuel cell system integrity, different scenarios of fast filling up to MPa are investigated. A pressure ramp rate is kept at a constant value with or without intermissions. All cases applied in this study indicate that the gas temperature in the tank does not always exceed 85 degrees Celsius until the end of filling. The temporal decrease of inside gas temperature is appeared after the rapid rise in the early 1 seconds of filling. It is estimated that the heat produced by compression of hydrogen transfers to the inside wall immediately, since the inner surface area to tank volume ratio becomes large as the tank size is small. Therefore the decrease of gas temperature obtained in this study is a characteristic phenomenon in small size tanks. 1. INTRODUCTION Recent environmental and energy safety issues promote the change of energy source from the fossil fuel to others. Hydrogen that is a clean fuel and an energy carrier represents a possible alternative energy source. Hydrogen can be used for a broad range of applications, as for the transportation sector the hydrogen energy is also considered as an alternative energy source. Recently hydrogen fuel cell vehicles (FCVs) which are expected to play an important role in the future have been researched significantly. The FCVs have a fuel cell stack instead of an internal combustion engine used for conventional vehicles. The fuel cell stack converts hydrogen gas with oxygen from the air into electricity directly to drive the wheels. The direct electrode reaction of hydrogen and oxygen provides higher energy conversion efficiency compared with combustion engines affected by Carnot cycle restriction. However, it is well known that the hydrogen energy density at atmospheric pressure is very low compared with fossil fuels used for conventional vehicles therefore a compressed hydrogen tank is considered in general use of FCVs. To store much hydrogen energy on the FCVs, an extremely high compression of hydrogen is required. Tank to store high pressure hydrogen can be categorized into four types [1]. Types I and II are a traditional steel storage which mainly employs the compressed natural gas vehicles. On the other hand Types III and IV, which are carbon fiber full-wrapped cylinders, are mainly developed and researched for FCVs since these allowable maximum pressure is higher than that of Types I and II. The hydrogen gas stored in the Types III and IV can be compressed up to MPa achieving the long-distance driving as well as that of conventional vehicles. 1

While the hydrogen is refuelled to the tank, pressure in the tank rises to MPa from several MPa. Since the refuelling should be completed within a few minutes because of user convenience, a fast filling of high pressurized hydrogen is concerned at hydrogen stations. However, high pressure ramp rate induces a rapid increase of gas temperature inside the tank. Such a high temperature due to the rapid compression of hydrogen gas compromises the structural integrity of the hydrogen storage system. For this reason, allowable maximum gas temperature inside the tank is set to 85 degrees Celsius [2,3]. Type III and IV tanks have respectively a metal liner and a plastic liner. Although the Type IV tank, which is used in this study, has an advantage of light weight, higher temperature rise due to the rapid compression of hydrogen gas during fast filling process is a disadvantage. Thermal property of plastic liner causes higher temperature rise in the tank. The mechanism of temperature rise during filling process for Type III and IV tanks has been significantly researched analytically and experimentally over the last decade. Dicken and Mérida [4] measured gas temperature at 63 points inside a 74 liters Type III tank during the hydrogen filling. Effects of the initial mass and fill rate on the temperature rise during filling were investigated. It is revealed that slower fillings produce a temperature field with a significant stratification in the vertical direction caused by buoyancy forces. Their experimental results are often used to validate computational fluid dynamics (CFD) models. Heitsch et al. [5], Suryan et al. [6], and Wang et al. [7] referred to these experimental results. Heitsch et al. validated a 3-dimensional model using the commercial CFD software CFX 11. Suryan et al. investigated the suitable turbulence model for the hydrogen fast filling process. Four turbulent models based on Reynolds Averaged Navier- Stokes equation were compared. Wang et al. validated a 2-dimensional axisymmetric model using the commercial CFD software Fluent 13.. These CFD approaches supplied detailed information on flow and temperature distribution inside the tanks during hydrogen fast filling. The CFD technique is also applied to other configurations and conditions. Galassi et al. [8] investigated the effect of different pressure patterns using CFX 12.1. A 3-dimensional model of a MPa type IV tank is assumed. Li et al. [9] studied the effects of tank geometry and inconstant mass flow rate on temperatures rise and distribution inside the tank during hydrogen fast filling. Cylinders of different length to diameter ratios and different inlet diameters were simulated by a 2-dimensional axisymmetric swirl CFD model built in Fluent 13.. Monde et al. [1] developed a simple thermodynamic model for filling of hydrogen tank. It was assumed that the gas temperature inside the tank is uniform, i.e. fluid dynamics inside the tank does not considered. The temperature rise during filling process is well predicted by the simple model considering heat flux through the tank wall estimated with a reasonable heat transfer coefficient. Kim et al. [11] investigated thermal flow characteristics during hydrogen filling process of a Type IV tank with an internal volume of 72 liters. The experimental results for 5 different initial pressures of the tank were compared with results obtained by a transient 3-dimensional numerical simulation considering conjugate heat transfer between hydrogen gas and tank wall. The change of hydrogen gas pressure in the tank was in good agreement, while the maximum temperature of the hydrogen gas inside the tank was over-predicted by the numerical simulation. Liu et al. [12] investigated experimentally the thermal behaviours such as gas temperature rise and distributions inside 35 MPa, 1 liters Type III tank during fast filling. While Zhao et al. [13] simulated the above experiment with a 2-dimensional axisymmetric simulation based on compressible fluid dynamics. Thermal condition of the tank during fast filling was revealed in detail. Zheng et al. [14] researched MPa, 74 liters Type III tank experimentally and numerically. Most studies on the hydrogen filling process suppose that the tank is used for automobile, namely relatively large tank is concerned. On the other hand, the volume of a compressed hydrogen tank for fuel cell motorcycles is assumed to be less than about 2 liters. There are not many researches on such 2

a small tank. To realize the fuel cell motorcycle, many problems concerning its relatively small size must be solved. Such a small tank may have different thermal characteristics during hydrogen fast filling compared with those of a large automobile tank. In this study, we experimentally investigate thermal characteristics of such a small tank during hydrogen fast filling. 2. EXPERIMENT A Type IV tank with 11 liters is used to investigate thermal conditions when high-pressurized hydrogen is filled to the tank. Outer diameter of the cylindrical tank is 23mm and the axial length 5mm. Initial pressure of the tank is set at about 1. MPa and initial gas temperature C. The tank is set inside an explosion containment chamber which inside temperature is controlled to keep C during hydrogen fast filling. It is a sever condition for the tank that the environmental temperature and initial tank temperature are C. Figure 1 shows the position of T type thermocouples of.5mm in diameter to measure temperature change during filling process. The thermocouples are inserted on the side opposite from the inlet nozzle. The temperatures on the inside and outside walls as well as the inside gas temperature are measured at upper, middle, and bottom points, denoted as points 1, 2, and 3. The thermocouples for measuring the inside gas temperatures are set 1mm away from the internal wall surface. Hydrogen gas cooled to about C to minimize the increase in gas temperature is supplied through a tube 3mm in diameter set on the opposite side of the thermocouples. The inlet nozzle is tilted 45 upward to ensure uniform temperature distribution [14]. Initial Temperature C Thermocouples Environment C T o2 T o1 45 Initial Pressure 1.MPa Hydrogen - C 3. RESULTS AND DISCUSSION 3.1 Effect of Pressure Ramp Rate Figure 1 Position of thermocouples When the hydrogen is refueled, a rate of pressure rise is kept at a constant value, 1. or.5 MPa/s. The tank pressure is controlled well until the internal pressure reaches MPa of the target pressure as shown in Figure 2. Filling time is about 69 seconds for the case of 1. MPa/s, and about 138 seconds for the case of.5 MPa/s. The inside gas temperature changes rapidly in the early 1 seconds shown in Figures 3, 4, and 5. The gas temperature reaches about 74 C which is maximum value during the hydrogen filling process. After the rapid rise, temperature decreases to about 65 C and increases again gradually. At the end of filling, the inside gas temperature reaches about C. The temporal decrease of inside gas temperature after the rapid rise which is not appeared clearly in fast fillings of large size tank is a characteristic phenomenon in small size tanks. It is estimated that the absorbed heat to the tank wall is larger than produced heat inside the tank after the rapid rise. Since the inner surface area to tank volume ratio becomes large as the tank size is small, the heat produced by compression of hydrogen transfers to the inside wall immediately. Significant difference in the maximum temperature is not appeared in two cases due to the fast heat transfer. Since the tank has a margin of 1 C to the allowable maximum temperature, it is possible that the pressure ramp rate is set faster than 1. MPa/s to reduce the filling time safely for user convenience. 3 T o3

The inside wall temperatures shown in Figures 6, 7, and 8 are similar to the results of inside gas temperatures. However, the inside wall temperatures at upper point are higher than other points in the early filling process. Since the inlet nozzle is tilted 45 upward, it is estimated that the hydrogen gas flow effectively through the upper wall surface, and that the heat transfer rate on the upper wall becomes higher. As a result, the gas temperature is lower than and as shown in Figures 3 and 4. Figure 9 indicates that the average outside wall temperature is almost kept at constant until the end of filling. However, it is found that the wall temperature in the case of.5 MPa/s starts to increase slightly after 1 seconds. It is estimated that the heat produced by compression of hydrogen gas reaches to the outside surface of the tank wall at about 1 seconds. Therefore, when the fast filling is finished by 1 seconds thermal conditions of the tank during hydrogen filling does not depend on the surrounding condition of the tank. 1.MPa/s.5MPa/s 2 1 1 2 Figure 2 Tank pressure during hydrogen fast filling (Initial pressure:1. MPa) Figure 3 Inside gas temperature under the pressure ramp rate 1. MPa/s 1.MPa/s.5MPa/s 1 1 1 1 Figure 4 Inside gas temperature under the pressure ramp rate.5 MPa/s Figure 5 Average gas temperature in the tank during hydrogen fast filling 4

2 1 1 Figure 6 Inside wall temperature under the pressure ramp rate 1. MPa/s Figure 7 Inside wall temperature under the pressure ramp rate.5 MPa/s 42 1.MPa/s.5MPa/s 41.5MPa/s 1 1 1.MPa/s 1 1 Figure 8 Average inside wall temperature Figure 9 Average outside wall temperature 3.2 Effect of Intermissions during Filling Process Hydrogen filling process with intermission is considered to control the temperature rise due to the fast filling of hydrogen. To complete the filling within 3 minutes for user convenience, 2 filling processes listed in Table 1 are designed. Figure 1 shows the filling process listed in Table 1. The filling process of 2 steps includes one intermission. After the hydrogen filling is performed with 1. MPa/s until 29 seconds, the hydrogen filling stops until 1 seconds. Then, hydrogen filling with 1. MPa/s is started again and it is kept until 1 seconds. The filling process of 4 steps includes 3 intermissions. The hydrogen filling stops 37 seconds at 19, 76, and 133 seconds. It is found that the pressure ramp rates are controlled well in the experiment as shown in Figure 11 compared with Figure 1. 2 steps 4 steps Table 1 Filling process with intermissions 29 1 1 1 3 3 19 56 76 113 133 1 1 1 2 2 5

4 steps 4 steps 2 2 steps 2 2 steps 1 1 2 1 1 2 Figure 1 Tank pressure of filling process listed in Table 1 Figure 11 Tank pressure obtained by experiments during hydrogen fast filling with intermissions Pressure 2 Pressure 2 1 1 2 1 1 2 Figure 12 Inside gas temperature and tank pressure (2 steps) Figure 13 Inside gas temperature and tank pressure (4 steps) The inside gas temperature changes rapidly in the early 1 seconds shown in Figures 12 and 13. After the gas temperature reaches about 74 C, the gas temperature decreases to 65 C at 3 seconds. This phenomenon is similar to the result of Figure 3. The intermission after the early 1 seconds is not effective clearly to decrease the maximum gas temperature in the tank. The intermissions should be carried out in the early 1 seconds at least. Even if there is a difference of 1 MPa between the tank pressure in the cases of 2 steps and 4 steps at 3 seconds, the effects of the tank pressure on the gas temperature are not clear. The inside gas temperature at the bottom points,, is decreases lower than other measurement points after about seconds. It is indicated that the temperature stratification in the vertical direction is produced in the tank due to buoyancy forces. Similar temperature profile in a Type IV tank with 74 liters is reported by Dicken and Mérida [4]. After the second filling starts at 56 seconds in the case of 4 steps, the inside gas temperature rises until the end of the second filling. The gas temperature at the upper measurement point,, is lower than the others during the hydrogen filling. While the gas temperature at the bottom measurement point,, becomes lower than the others during the stop of filling. Namely the gas temperature distribution having lower temperature in the upper region produced by the injected gas is changed immediately to the distribution where the lower temperature region is in the bottom region at the stop of filling. At the other intermissions, similar phenomenon is appeared. 6

The inside wall temperature also rises rapidly in the early 1 seconds shown in Figures 14 and 15. However, the temperature at upper point is higher than other points in the early process since the inlet nozzle tilted 45 upward makes the heat transfer rate on the upper wall higher. 2 Pressure 1 1 2 2 Pressure 1 1 2 Figure 14 Inside wall temperature and tank pressure (2 steps) Figure 15 Inside wall temperature and tank pressure (4 steps) 42 4 steps 41 39 2 steps 1 1 2 Figure 16 Average outside wall temperature Figure 16 shows the average outside wall temperature. The surround gas temperature is almost kept at constant until the end of filling, while the outside wall temperatures increase gradually after 1 seconds. Since the similar phenomenon is also observed in Figure 9, about 1 seconds is necessary to reach the heat produced by compression of hydrogen gas to the outside wall of the Type IV tank. 4. CONCLUSIONS To investigate the thermal characteristics of the Type IV tank developed for motorcycles, different scenarios of hydrogen fast filling up to MPa were carried out to compare each other. All cases applied in this study indicate that the gas temperature in the tank does not always exceed the allowable maximum temperature 85 C until the end of filling. The inside gas temperature changed rapidly in the early 1 seconds, and reached about 74 C which is maximum value when the pressure ramp rate was kept at a constant value, 1. or.5 MPa/s. The temporal decrease of inside gas temperature is appeared after the rapid rise. It is estimated that the heat produced by compression of hydrogen transfers to the inside wall immediately, since the inner surface area to tank volume ratio becomes large as the tank size is small. Therefore the decrease of gas temperature obtained in this study is a characteristic phenomenon in small size tanks. 7

The inside wall temperature at upper point was higher than other points in the early filling process because the inlet nozzle is tilted 45 upward in this experiment. It is estimated that the heat transfer rate on the upper wall became higher. As a result, the gas temperature at upper point was lower than other points. About 1 seconds is necessary to reach the heat produced by compression of hydrogen gas to the outside surface of the tank. Therefore the surrounding condition of the tank is not important to estimate the inside gas temperature change for the fast filling finished by 1 seconds. To control the temperature rise due to the fast filling of hydrogen, the effect of intermissions during filling process were investigated. As a result, the intermissions were not effective clearly to decrease the maximum gas temperature in the tank. The intermissions should be carried out in the early 1 seconds at least. The inside gas temperature at the bottom points decreased lower than other measurement points after the stop of filling. It is indicated that the temperature stratification in the vertical direction was produced in the tank immediately due to buoyancy forces. ACKNOWLEDGMENTS This work was supported by the New Energy and Industrial Technology Development Organization of Japan (NEDO) under a research program "Development of Hydrogen Utilization Technology." REFERENCES 1. Mori, D., and Hirose, K., Recent challenges of hydrogen storage technologies for fuel cell vehicles, International Journal of Hydrogen Energy, 34, 29, pp.4569-4574. 2. SAE International. Technical information report for fuel system in fuel cells and other hydrogen vehicles, J2579, revised; January 29. 3. International Standard Organization, Gaseous hydrogen and hydrogen blends land vehicle fuel tanks, ISO/TS 15869, 29. 4. Dicken, C.J.B., and Mérida, W., Measured effects of filling time and initial mass on the temperature distribution within a hydrogen cylinder during refuelling, Journal of Power Sources, 165, 27, pp.324-336. 5. Heitsch M., Baraldi D., and Moretto P., Numerical investigations on the fast filling of hydrogen tanks, International Journal of Hydrogen Energy, 36, 211, pp.26-2612. 6. Suryan A., Kim H.D., and Setoguchi T., Comparative study of turbulence models performance for refueling of compressed hydrogen tanks, International Journal of Hydrogen Energy, 38, 213, pp.9562-9569. 7. Wang G., Zhou J., Hu S., Dong S., and Wei P., Investigations of filling mass with the dependence of heat transfer during fast filling of hydrogen cylinders, International Journal of Hydrogen Energy, 39, 214, pp.43-4388. 8. Galassi M.C., Baraldi D., Iborra B.A., and Moretto P., CFD analysis of fast filling scenarios for MPa hydrogen type IV tanks, International Journal of Hydrogen Energy, 37, 212, pp.6886-6892. 9. Li Q., Zhou J., Chang Q., and Xing W., Effects of geometry and inconstant mass flow rate on temperatures within a pressurized hydrogen cylinder during refueling, International Journal of Hydrogen Energy, 37, 212, pp.43-52. 1. Monde, M., Woodfield, P., Takano, T., and Kosaka, M., Estimation of temperature change in practical hydrogen pressure tanks being filled at high pressures of 35 and MPa, International Journal of Hydrogen Energy, 37, 212, pp.5723-5734. 11. Kim, S.C., Lee, S.H., and Yoon, K.B., Thermal characteristics during hydrogen fueling process of type IV cylinder, International Journal of Hydrogen Energy, 35, 21, pp.683-6835. 12. Liu Y., Zhao Y., Zhao L., Li X., Chen H., Zhang L., Zhao H., Sheng R., Xie T., Hu D., and Zheng J., Experimental studies on temperature rise within a hydrogen cylinder during refueling, International Journal of Hydrogen Energy, 35, 21, pp.2627-2632. 8

13. Zhao L., Liu Y., Yang J., Zhao Y., Zheng J., Bie H., and Liu X., Numerical simulation of temperature rise within hydrogen vehicle cylinder during refueling, International Journal of Hydrogen Energy, 35, 21, pp.92-81. 14. Zheng J., Guo J., Yang J., Zhao Y., Zhao L., Pan X., Ma J., and Zhang L., Experimental and numerical study on temperature rise within a MPa type III cylinder during fast refueling, International Journal of Hydrogen Energy, 38, 213, pp.1956-1962. 15. Matsuno, Y., Maeda, Y., Otsuka, N., Tamura, Y. and, Mitsuishi, H., Attained temperature during gas fueling and defueling cycles of compressed hydrogen tanks for FCV, Proceedings of 4th International Conference of Hydrogen Safety, San Francisco, Paper 164, 211. 9