GOST R CERTIFICATION SYSTEM FEDERAL AGENCY OF TECHNICAL REGULATION AND METROLOGY CERTIFICATE OF CONFORMITY

Similar documents
Further technical information is available on

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Technical Data. General specifications. Rated operating distance s n 2 mm

Electro-Pneumatic Converter YT-940 SERIES

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

Operating Instructions

Technical Data. Dimensions

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm

Technical Data. Dimensions

IA CERTIFICATE (Revision 3 Revised for Annual Review) Hazel Grove Stockport Cheshire SK14 6NG United Kingdom

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. Dimensions

1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS

Technical Data. General specifications. Rated operating distance s n 5 mm

Operating Instructions

IECEx Certificate of Conformity Annexe

NZQA registered unit standard version 3 Page 1 of 7. Plan electrical installations for explosive atmospheres

Operating Instructions

DK46 - DK800 Supplementary instructions

Technical Data. Dimensions

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Technical Data. Dimensions

IECEx Certificate of Conformity

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

Magnetic level switch type MR783 Instruction Manual

NZQA registered unit standard version 2 Page 1 of 7. Conduct a conformity assessment of explosion-protected apparatus

A Unified Marking System for Ex Equipment

IA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review)

Certificate of Conformity

VG5 Supplementary instructions

G96 Series BASOTROL Dual Operator Valve

Supplementary Operator s Manual 42/24-14 EN Rev. 3

EX-RECESSED CEILING LIGHT FITTINGS

CABLE ENTRIES IN HAZARDOUS AREAS CORRECT SELECTION, INSTALLATION AND MAINTENANCE

Technical Data. Dimensions

Certificate of Compliance

Supplementary Installation and Operating Instructions. Variable Area Flow Meters SGK-1 Ex SGK-2 Ex SGK-3 Ex. Category: II 2G Ex IIC II 3G Ex IIC

RTD temperature probes

Pressure controls for hydro carbons, zone II applications, Type KPE

Junction Boxes Series 8118

ComEx Actuating elements

NZQA registered unit standard version 1 Page 1 of 8. Conduct detailed inspection of electrical installations for explosive atmospheres

Arran LED Floodlight Luminaire

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Explosion Protection Technology Pty Ltd

Technical Data. Dimensions

Inductive slot sensor

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)

RTD Temperature sensor TH11

Guidelines to the standard IEC60601

slra of Gonformity IECEx Cert f cate )ol4- ob cst

C&G 2395 Exam Paper June Section A-All questions carry equal marks. Answer all three questions. Show all calculations.

UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function Gas Control Valves

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E

Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85

Pull-rope emergency stop switch Type HENEX and SEGEX OPERATING INSTRUCTIONS

Certification of EXPLOSION PROTECTED ELECTRICAL EQUIPMENT

Installation, Operation, & Maintenance Manual. MODEL: Watlow Controller P53 Direct, P53 Remote

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations

GS-20/25 and GS-40/45 Series Single-block Multi-function Gas Control Valves

Project: Consultant : MEP Contractor: PREPARED BY: DORMAN SMITH SWITCHGEAR - DUBAI REVIEWED BY CONSULTANT : Page 1 of 15

ELECTRICAL (COMPREHENSIVE) SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29 CFR CFR , ,

Pressure switch KP-E. Data sheet

Manual Power relay SR853

SPECIFICATIONS ATTENTION

Torque Tube TB300 Digital Transmitters

BGA158 Series CE Approved Class A Shutoff Gas Valve

MIE TALK May INTRODUCTION. South African Flameproof Association Page 1 of 19

PURGEX X Purge Controller D Version

Pressure & Temperature Switches

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations

Monitoring device NTS 30

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)

J21K Series DIFFERENTIAL PRESSURE SWITCH. features

GAS FUEL VALVE FORM AGV5 OM 8-03

II 2G EEx ia IIC T6. Ignition protection class

PURGEX X Purge Controller E Version. User s Manual

Z, Y, and X PURGE INDICATORS / CONTROLLERS

Session #: Selection of Explosion Protected Equipment for Hazardous Locations

IECEx Cert f cate of Gonform ty. IECEX SIR ' X issue No.:1 9-e j{ca!ells_tgryi _ lssue No. 1 ( ) lssue No.

GM-7000 Series CE Approved Gas Control Valve

XCE: Explosionproof Control Enclosures

Pressure switch, Differential pressure switch and Thermostat RT-E

ECP Series Explosionproof Enclosures for OEM Applications. Optimized design, extensive sizes, and fast lead times.

Pressure Measurement Single-range transmitters for general applications

Sanitary RTD Temperature sensor TH17. Measuring System Sanitary RTD assembly with connection head TH17 for food and dairy applications.

Floodlight LED. Series Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

VA FLOWMETERS Supplementary Instructions

UHrasonic Sensor VEGASON60 type series SN6*.CI**H***

The evolution of the Ex-proof flame path

GENERAL APPLICATION NOTES

Conductor Bushings Series 8174

Inspection of in-service Explosion Protected Equipment - Unsafe Conditions and Cures. Johannes Auret, Explolabs and CERTEX SAFA SYMPOSIUM 2011 CTICC

Transcription:

CERTIFICATE OF CONFORMITY No. ROSS US.GB05.V03061 Valid from 8/12/2010 through 8/12/2013 No. 0422555 CERTIFICATION AGENCY ROSS RU.0001.11GB05 NONPROFIT INDEPENDENT RESEARCH ORGANIZATION (), CERTIFICATION CENTER FOR EXPLOSION- PROOF AND MINE ELECTRICAL EQUIPMENT (CCVE) CCVE, P.O. Box 22, Moscow 109377 Tel./fax: +7 (495) 554-2494, 554-1238, 554-1257, 554-0150, 554-5042, 557-8244, 558-8353, 558-8141, 743-6830, ww.ccve.ru PRODUCT VC4, VH4, HV4, TSC4, CN4, TN4, and CSC4 series explosion-proof enclosures OK 005 Code (OKP): with an EBT contact block, EH (PP, PB, S, KS) series pushbuttons and selector switches, and EL series indicator lights with explosion protection labeling, and combustible dust ignition protection 34 6474 labeling in accordance with the addendum Serial production IS IN COMPLIANCE WITH REGULATORY DOCUMENTS GOST R 52350.0-2005 (International Electrotechnical Commission (IEC) 60079-0:2004) GOST R 52350.1-2005 (IEC 60079-1:2003) GOST R 52350.7-2005 (IEC 60079-7:2006) GOST R 52350.18-2006 (IEC 60079-18:2004) GOST R IEC 61241.0-2007; IEC 61241-1:2004 Russian TN VED Code: 8536 90 MANUFACTURER: Adalet/Scott Fetzer Company, 4801 West 150 th Street, Cleveland, Ohio, 44135, USA CERTIFICATE ISSUED TO Adalet/Scott Fetzer Company 4801 West 150 th Street, Cleveland, Ohio, 44135, USA Telephone: 216-267-9000, fax: 216-267-6710 ON THE BASIS OF Test certificate No. 314.2010-I dated 7/30/2010, CCVE Testing Laboratory (TL) (reg. No. ROSS RU.0001.21GB04); Certificate of analysis results of the certifiable product's state of production No. 15-PP/10 dated 3/31/2010 CCVE Certification Agency (reg. No. ROSS RU.0001.11GB05) ADDITIONAL INFORMATION Certification scheme 3a Certificate is valid with 7-page addendum Inspection check-up July 2011, July 2012 Initials and surname Initials and surname Certificate is legally valid on all Russian Federation territory Form printed by ZAO OPTsION (License No. 05-05-09/003 FNS RF, level C)) Tel: (495) 648-6068, 608-7617, Moscow 2009

NONPROFIT INDEPENDENT RESEARCH ORGANIZATION, CERTIFICATION CENTER FOR EXPLOSION-PROOF AND MINE ELECTRICAL EQUIPMENT, ROSS RU.0001.11GB05 CCVE, P.O. Box 22, Moscow 109377, Tel.: 557-82-44 ADDENDUM TO CERTIFICATE No. ROSS US.GB05.V03061 Drafted in compliance with par. 7.10.1 of the Rules of Certification of Electrical Equipment Explosive Atmospheres, PB 03-538-03, registered by the RF Ministry of Justice on 4/23/03, registration number 4440 1. APPLICATION AND AREA OF USE VC4, VH4, HV4, TSC4, CN4, TN4, CSC4 series explosion-proof enclosures with an EBT contact block, EN (PP, PB, S, KS) series pushbuttons and selector switches, and EL series indicator lights are intended use as components (modules) construction of various control systems and other systems. The areas of use are class 1 and 2 explosion-hazard zones according to GOST R 52350.10-2005 (IEC 60079-10:2002) classification of spaces and exterior installations in accordance with GOST R 52350.14-2006 (IEC 60079-14:2002) and other regulatory documents governing the use of electrical equipment in explosion-hazard zones and in zones that are hazardous due to ignition of combustible dust in accordance with GOST R IEC 61241-14-2008. 2. BASIC TECHNICAL SPECIFICATIONS Class of electrotechnical item safeguarding people from electrical shock according to GOST 12.2.007.0-75 Ambient temperature range during operation, C: -VC4 -VH4 -HV4 -TSC4 -CN4 ( T5 temperature class) -CN4 ( T6 temperature class) -TN4 -CSC4 -EBT series contact blocks -EL series indicator lights I -50 +55-50 +55-20 +55-20 +70-20 +55-20 +40-20 +70-20 +55-55 +60-55 +60 Explosion protection labeling: -Explosion-proof enclosures series VC4, VH4, HV4 TSC4 CN4 TN4 CSC4 2 Ex e II T5/T6 X 2 Ex e II T4/T5/T6 X 2 Ex d e mb IIC T5/T6 X 2 Ex e II T4/T5/T6 X 2 Ex d e mb IIC T5/T6 X

Addendum to Certificate of Conmity No. Ross US. GB05.V03061 Page 2 -EBT series contact blocks -EN (PP, PB, S, KS) series pushbuttons and selector switches -EL series indicator lights Combustible dust ignition protection labeling: -enclosures of series VC4, VH4, HV4 TSC4 CN4 TN4 CSC4 -EN (PP, PB, S, KS) series pushbuttons and selector switches -EL series indicator lights Ex d e IIC U EX d e IIC U Ex e mb IIC U/ Ex mb IIC U Ex td A21 T200 C X Ex td A21 T200 C X Ex td A21 T200 C X Ex td A21 T100 C X Ex td A21 T200 C X Ex td A21 U Ex td A21 U VC4 series explosive-proof enclosures Ambient temperature during operation, C From -50 to +55 VH4 series explosive-proof enclosures Ambient temperature during operation, C From -50 to +55 HV4 series explosive-proof enclosures Ambient temperature during operation, C From -20 to +55 Maximum operating voltage of alternating or direct current, V 8000 Maximum cross-section of supply line, mm 2 From 10 mm 2

Addendum to Certificate of Conmity No. Ross US. GB05.V03061 Page 3 to 300 mm 2 TSC4 series explosive-proof enclosures Ambient temperature during operation, C From -20 to +70 CN4 series explosive-proof enclosures Ambient temperature during operation, C From -20 to +55 TN4 series explosive-proof enclosures Ambient temperature during operation, C From -20 to +70 CSC4 series explosive-proof enclosures Ambient temperature during operation, C From -20 to +55

Addendum to Certificate of Conmity No. Ross US. GB05.V03061 Page 4 EBT series contact blocks Maximum voltage, V: -of alternating current 600 -of direct current 300 Maximum current, A 10 EL series indicator lights Power supply, V 120 24 12 Capacity, W 1.2 0.6 0.6 3. DESCRIPTION OF ITEM DESIGN AND EXPLOSION-PROOF MEASURES VC4, VH4, HV4, TSC4, CN4, TN4, and CSC4 series explosion-proof enclosures are made of painted carbon steel (the number 4 indicates the housing material painted carbon steel). Housings of VC4X, VH4X, HV4X, TSC4X, CN4X, TN4X, and CSC4X series explosion-proof enclosures can be made of type 304 stainless steel (the designation 4X indicates the housing material type 304 stainless steel). Housings of VC4X6, VH4X6, HV4X6, TSC4X6, CN4X6, TN4X6, and CSC4X6 series explosion-proof enclosures can be made of type 316L stainless steel (the designation 4X6 indicates the housing material type 316L stainless steel). VC4 and VH4 series explosion-proof enclosures have a box-like housing with a cover made out of steel. Certified conduit entries are mounted on the sides of the housings. Certified add-ins can be installed in the housing. HV4 series explosion-proof enclosures are steel box-like housings in which a high-voltage insulator is installed connection of cable conductors. Conduit entries are mounted on the sides of the housing. The cover of HV4 series explosion-proof enclosures is attached to the housing with bolts and hinges and has sealing gaskets. TSC4 series explosion-proof enclosures are steel box-like housings inside which certified Ex-components can be mounted. Conduit entries are mounted on the sides of the housing. The cover of TSC4 series explosion-proof enclosures is attached to the housing with bolts and has sealing gaskets. CN4 series explosion-proof enclosures have a housing and cover on a hinged joint; the cover is attached with screws. The housing and cover are made of steel. Certified Ex-components can be installed in the housing. Certified conduit entries are mounted on the sides of the housing. Certified add-ins can be mounted on the cover: EBT series and EH (PP, PB, S, KS) series pushbuttons and selector switches, and EL series indicator lights. The housing of CN4 series explosion-proof enclosures has a

Addendum to Certificate of Conmity No. Ross US. GB05.V03061 Page 5 sealing gasket between the housing and the cover at least an ingress rating. TN4 series explosion-proof enclosures have a housing and mounted cover on hinges that is attached with screws. Certified Ex-components are mounted in the housing. Certified conduit entries are mounted on the sides of the housing. The housing of TN4 series explosion-proof enclosures has a sealing gasket between the housing and the cover at least an ingress rating. The housing and cover are made of steel. CSC4 series explosion-proof enclosures have a housing and a cover that is attached with bolts. Certified Excomponents are mounted in the housing. Certified conduit entries are mounted on the sides of the housing. The housing of CSC4 series explosion-proof enclosures has a sealing gasket between the housing and the cover at least an ingress rating. The housing and cover are made of steel. EBT series contact blocks, EH (PP, PB, S, KS) series pushbuttons and selector switches, and EL series indicator lights are Ex-components and are intended installation in CN4 and CSC4 series explosion-proof enclosures. A detailed description of the design of VC4, VH4, HV4, TSC4, CN4, TN4, and CSC4 series enclosures, with EBT series contact blocks, EH (PP, PB, S, KS) pushbuttons and selector switches, and series EL indicator lights is included in the operating manuals and registration certificates. The explosion-proof nature of VC4, VH4, HV4, TSC4, CN4, TN4, and CSC4 series enclosures, with EBT series contact blocks, EH (PP, PB, S, KS) pushbuttons and selector switches, and EL series indicator lights, depending on configuration, is ensured with "explosion-proof enclosure" types of protection from explosions according to GOST R 52350.1-2005 (IEC 60079-1:2003), "e type protection" according to GOST R 52350.7-2005 (IEC 60079-7:2006), "sealing with (m) compound" of "mb" level according to GOST R 52350.18-1006 (IEC 60079-18:2004), and the execution of their design in compliance with requirements of GOST R 52350.0-2005 (IEC 60079-0:2004). The combustible dust ignition protection nature of VC4, VH4, HV4, TSC4, CN4, TN4, and CSC4 series boxes with EH (PP, PB, S, KS) series pushbuttons and selector switches and EL series indicator lights is ensured by meeting the requirements of IEC 61241-1- 2004 and executing their design according to GOST R IEC 61241-0-2007. The labeling placed on the housing of VC4, VH4, HV4, TSC4, CN4, TN4, and CSC4 series boxes with EBT series contact blocks, EH (PP, PB, S, KS) series pushbuttons and selector switches, and EL series indicator lights includes the following inmation: mark or name of manufacturer; name of item; sequential number of item according to the numbering system of the manufacturer;

Addendum to Certificate of Conmity No. Ross US. GB05.V03061 Page 6 explosion protection labeling; combustible dust ignition protection labeling; warning label "Disconnect from power grid prior to opening!"; ambient temperature range during operation; name or mark of certification center and certificate number and other inmation required by regulatory and technical documentation that the manufacturer must incorporate into the labeling. 4. SPECIAL CONDITIONS TO ENSURE OPERATIONAL SAFETY The X sign, following the explosion protection labeling, means that when operating VC4, VH4, HV4, TSC4, CN4, TN4, and CSC4 series explosion-proof enclosures with EBT contact blocks, EH (PP, PB, S, KS) series pushbuttons and selector switches, and EL series indicator lights, it is necessary to comply with the following special conditions: 1. All utilized wires or cables must be suitable a temperature of 80 C. 2. All unutilized openings must be equipped with certified covers of material equivalent to the housing materials and must comply with the level of protection. 3. The number of wires entering the junction box, taking into consideration the number of internal couplings (excluding shunts and ground wires) must not exceed the level indicated in the operating instructions each size of junction box. 4. Upon installation of pushbuttons, selector switches, and indicator lights with "d e" and "e mb" type explosion protection in an explosion-proof enclosure, the enclosure must be labeled, depending on the upper ambient temperature value, in the following manner: - 2 Ex de mb IIC T6 use in ambient temperature from -20 C t amb +40, or - 2 Ex de mb IIC T5 use in ambient temperature from -20 C t amb +55. 5. After completion of installation, all creepage path distances and electrical clearances must correspond to Table 1 in the GOST R 52350.7-2005 standard. 6. The EBT series contact block must be mounted on a hard surface, using mounting devices. 7. The EBT series contact block can be installed in an explosion-proof enclosure with "d" type explosion protection or "e" type protection. 8. The EBT series contact block must be mounted so that there is a minimum of a 10 millimeter clearance from any conductive surface. 9. Prior to disconnecting wires from EBT series contact blocks, the wires must be de-energized. 10. Two wires with a cross-section of 0.5 mm 2 to 4 mm 2 can be connected to an EBT series contact block. The insulation of the wires must be stripped to a length of 10-12 mm.

Page 7 Addendum to Certificate of Conmity No. Ross US. GB05.V03061 11. The maximum operating ambient temperature to use the EBT series contact block may not exceed 73 C. 12. When cables are installed in ambient temperature conditions of lower than minus 10 C, it is necessary to use cables suitable these conditions. Safe operating conditions are set th in the operating instructions. 5. LIST OF DRAWINGS APPROVED BY THE CERTIFICATION CENTER Document number Date signed Date approved DS545M version C 5/6/99 7/30/2010 DS546M version C 2/3/00 7/30/2010 DS652 version C 8/20/01 7/30/2010 DS553M version E, 2 pages 2/17/00 7/30/2010 DS594M version D, 2 pages 09/12/00 7/30/2010 DS585 version D 08/04/00 7/30/2010 DS593M version E, 2 pages 09/11/00 7/30/2010 DS653 version C 8/22/01 7/30/2010 DS654 version C 8/22/01 7/30/2010 DS655 version B 8/22/01 7/30/2010 DS813 version C, 2 pages 06/10/2009 7/30/2010 DS814 version C, 2 pages 10/06/2009 7/30/2010 DS815 version A 03/08/10 7/30/2010 DS816 version A 03/08/10 7/30/2010 DS817 version A 08/14/09 7/30/2010 DS819 version A 03/08/10 7/30/2010 DS820 version A 03/08/10 7/30/2010 DS831 version A, 3 03/12/2010 7/30/2010 DS842 version A 9/18/2009 7/30/2010 DS843 version A 9/18/2009 7/30/2010 DS844 version A 8/14/2009 7/30/2010 DS845 version A 9/18/2009 7/30/2010 DS846 version A 11/17/2009 7/30/2010 DS847 version A 9/18/2009 7/30/2010 DS849 version C, 2 pages 7/22/2009 7/30/2010 DS854 version A 03/08/2010 7/30/2010 DS861 version A 07/06/2009 7/30/2010 DS878 version A 11/05/2010 7/30/2010 DS891 version A, 5 pages 6/28/2010 7/30/2010 DS885 version A, 4 pages 6/24/2010 7/30/2010 DS887 version A, 4 pages 6/24/2010 7/30/2010 DS888 version A 6/23/2010 7/30/2010 DS893A version A, 5 pages 6/28/2010 7/30/2010 Changes to the approved drawings or designs of the items may be made only with the approval of CCVE.