Technical Topics. Softener Elution Studies TT

Similar documents
Softeners Clack Model V125DTH Medical / Industrial Series Operation and Service Manual

Easy Nest Kits. Installation Suggestions

NORMAL OPERATING DISPLAYS GENERAL OPERATION

The ultimate in water softening

Operation Manual. Carbon Filtration Industrial Drive, Orlinda, TN fax

AQUAMATIC EASY NEST KITS INSTALLATION SUGGESTIONS

Your Bonus. Steps for doing the Homework. Make sure you convert to the correct units of measure:

Prestige Water Equipment Ltd.

Autotrol Performa ProSoft

A Perspective on Filter Cartridge Issues

Prestige Water Equipment Ltd.

O&M Receiving and Inspection. Storage of Water Treatment Media

DRS4-RM Manual. Set Up Instructions for DRS4 Series Single Tank

Performa Cv Twin Alternating and High Flow Systems. Manual Supplement

Installation Operation Maintenance Manual

INSTALLATION & START-UP INSTRUCTIONS FLECK 9100SXT METER TWIN ALTERNATING WATER SOFTENER SYSTEMS

Certified Pool/Spa Operator Course Pool Calculations

Installation Operation Maintenance Manual

Installation Operation Maintenance Manual

Commercial Softeners. Installation, Operation & Maintenance Guide. Manual 002.1

Operation and Maintenance Manual for

INSTALLATION & START-UP INSTRUCTIONS. Clack WS1 & WS1.25 METER WATER SOFTENER SYSTEMS

Installation Operation Maintenance Manual

IWT 565 Series HTO Series Operation Manual

265 Series Valve Operation Manual

Operation and Maintenance Manual for

SALT GENERATOR FOR ABOVEGROUND POOLS

Duplex Commercial Softeners

Installation and Instructions 2. Product Features 3-6. Key Pad Functions 7. Distributor Information Programming Guide 8. Master Programming Guide 9-14

Matrix Pre-Treatment System

YMCA of the USA. YMCA Pool Operator s Manual (3 rd Edition)

Owner s Manual. R&M Water Group TM. Models: SA-TECH PLUS 40 DB SA-TECH PLUS 48 DB

Compressed Air - Food/Bev. Presented By: Adam Zimmerman

Worksheet: Solubility

Instructions for SILEX 1C Mixed bed cartridge filter

KRO AUGUST Prepared for: WashTec Australia 1, 33 Maddox Street Alexandria NSW 2015 Sydney, Australia

Installation Operation Maintenance Manual

INSTRUCTION MANUAL. Demineralizer. 24R Two Stage Deioniser. Brand :

Installation Operation Maintenance Manual

SOFTENER D-DF & D-UF Series

CAT Course Trust Your Water

Best Practices Pneumatics Machine & Design. Written by Richard F. Bullers, CFPPS as published in Fluid Power Journal, July/August 2016

Softener / Filter Fleck Model 2850 SXT Medical / Industrial Series Operation and Service Manual

CAN 565 Series. Softener Manual

Swimming Pool IAQUALINK WEB CONNECT

2300 Duplex Softener Manual

With 960 Series Control Water Conditioning Control System Installation, Operation and Maintenance Manual

Tech Manual Powerline Softener (PS) Series

ES 2070 SV. Electronic controller for water softening units. Instruction Manual. Software version 1.00

AUTOMATIC SOFTENERS SERIES: AM/DT AM/RDT AM/DV AM/RDV AM/D METER AM/RD METER INSTRUCTIONS MANUAL WARNING!

Instruction Sheet. Important Note: Information that requires special emphasis. Note: Information that supplements points in the main text.

INSTRUCTION MANUAL. Automatic Water Softener System. Model: PSE-08. Xsential Water Filtration Systems

Control Valves, Fittings and Accessories

Relative Humidity Calibration Kit

Evaluation of Hydropath Clearwell Technology On Carbonate Brine Scaling Using Tube Blocking Method

State of Nevada Department of Transportation Materials Division METHOD OF TEST FOR SAND EQUIVALENT

ACTIVATE YOUR WARRANTY BY REGISTERING YOUR PRODUCT AT

Ultima Salt System Overview

Installation and Operation Instruction Manual INSMAN-200. Industrial Sand Media And Deep Bed Sand Media Filters

Technical Service Bulletin March 2015 TSB142.01

Simplified Start-Up Checklist For Fully-Pressurized Seasonal Systems

Owners Manual Models: 075-AQF-CX. Aquatrol Backwashing Catalytic Carbon Filter. Visit us online at.

TECHNICAL BENEFITS OF CJS / RAISE HSP. Technical Advantages

DW Module 8: Distribution Answer Key

The use of the analytical balance, and the buret.

HOW TO OPEN YOUR POOL

MiSP Solubility L2 Teacher Guide. Introduction

Process Nature of Process

S P A C A R E G U I D E

Calcimeter Instruction Manual

Pure Water Power Purification System 4-Stage RODI Operations Manual

Accu-Tab Systems 1000 Series by Axiall Corporation

Total Alkalinity TOO HIGH TOO LOW. Ideal. Difficulty Adjusting. Low ph Corrosion ph Fluctuation ppm. Cloudy Water High ph

CL02 INSTRUCTION MANUAL

CHM 2045L Physical Properties

V230 VALVE OPERATING MANUAL

V230 VALVE OPERATING MANUAL

US Water Systems Synergy Model 9000/9100/9500 Service Manual

Chloramines Removal Filter CLF20 and CLF35 Models

EMERGENCY WALL MOUNTED HAND OPERATED DELUGE SHOWER

MET 335W Fluid Mechanics Laboratory. Lab 1: Bourdon Tube Calibration. Nick Peak

POOL CARE GUIDE. The E-Z Clor System To Perfect Pool Water.

Technical Service Bulletin October 2013 TSB135.03

SpectraPure PUMPED RO SYSTEMS (PSP) User s Manual for PSP-1500 Systems

Pool Water Chemistry Guide

V43 Pressure Actuated Water Regulating Valve

RAM 4021 Operation Manual

Magnum Cv Series. Installation and Service Manual

ARM & HAMMER Baking Soda

IMPROVING QUALITY THROUGH INNOVATION: A FULLY AUTOMATED SOLUBLE SALT METER

CULLIGAN CSM SERIES WATER SOFTENER

CTB3365x Introduction to Water Treatment

Autotrol Performa Filter Valve Series

Culligan Gold Series Water Softener and Culligan Total Home Water Conditioner

Figure 1. Example of volume of water required for an unknown sample

Accu-Tab Systems 2000 P Series by Axiall Corporation

Technical Service Bulletin July 2014 TSB

Softener Manual Installation / Operation Manual

Introduction Advantages of cooperating with Our service - our conditions Our standard central control valve

SIZING THE WELL-X-TROL

Transcription:

Technical Topics TT-035-1204 Water softeners are critical components in many commercial and industrial water-using systems. By removing calcium and magnesium ions (hardness) from a facility s or system s water supply, a softener plays a key role in helping prevent hard water-related problems scale, corrosion, boiler tube failure and flow restriction, to name a few. These and other problems caused by hard water cost business and industry millions, perhaps billions of dollars annually. It is important, then, that a facility s softener be maintained in good operating condition to assure a continuous supply of soft water. A simple maintenance program will help keep a softener running at peak efficiency. This would include inspection of the softener s control head for proper operation, periodic laboratory analysis of the softener resin for physical condition and cleanliness, and the regular use of a resin cleaner to prevent fouling of the resin beads with iron, manganese and other contaminants. With a properly operating control head and clean resin in good condition, a softener will perform at maximum efficiency and capacity if the regeneration procedure is correct. The regeneration procedure consists of four cycles backwash, brine draw, slow rinse and fast rinse. Each cycle plays an important part in effecting good regeneration, and flow rates during each are critical. During backwash, water flows upwards through the bed to flush particulate matter from the resin bed and to reclassify or fluff up the bed. The backwash flow rate must be sufficient to expand the bed 1½ times for thorough reclassification and cleaning. This requires approximately 6 gallons per minute (gpm) per square foot of softener surface area. The backwash cycle should last 10-15 minutes. In the brine cycle, water passing over a venturi educts brine from the brine tank. The eduction water and brine mix and pass down through the resin bed. The eduction water/brine flow rate are critical to assure the complete exchange of sodium ions onto the resin beads. Brine eduction (brine draw) should be completed in 12-20 minutes. When brine draw is complete, water continues to flow through the resin bed in the slow rinse cycle. This slow rinse acts to push the brine through the bed and complete the ion exchange. Here again the flow rate is important because it must be fast enough to provide removal of the calcium and magnesium ions that the sodium ions have replaced, yet it must be slow enough to allow sufficient brine/resin contact. The slow rinse cycle should take about 30-45 minutes. At the end of the slow rinse cycle, the ion exchange is complete, and the fast rinse cycle starts. The function of the fast rinse is to remove the remaining brine from the softener column. The flow rate is accelerated here to provide for complete flushing of the brine from the resin bed. A flow rate of 5-6 gpm per square foot of softener surface area is normally used for fast rinse. When the fast rinse is done (10-15 minutes), regeneration is complete and the softener is ready to be put back in service. To reiterate, the flow rates of brine and/or water during each of the cycles in the regeneration procedure must be correct for proper regeneration of the resin bed to occur. In addition, the salt brine solution used must be saturated for the regeneration to be complete. S:share\topics\technical topics\tt-35 Page 1 of 5

A useful tool for assuring correct flow rates and brine concentration is a softener elution study. An elution study procedure, work sheet and brine concentration curve graph follow this discussion. Use of this tool by the water treatment technician or plant operator will allow them to identify and correct problems in a softener s regeneration function Softener Elution Study Procedure Before beginning the study, make certain that the softener drain line is open so that samples can be collected. Ideally, there should be sufficient space beneath the line to place a 2½ gallon pail, or at least a one gallon jar or beaker. This is so that flow rates can be determined by recording the time necessary to fill a specified volume. Using a salimeter, determine that the brine in the brine tank is at 100% of saturation. If brine is less than 100%, add salt and let stand until 100% saturation is attained. Run elution study using the following procedures: 1. Place the softener into the regeneration cycle. First stage will be Backwash. Using either the one gallon or 2½ gallon container, time how long it takes to fill the container with the backwash water. Calculate the backwash flow rate. Proper backwash flow rate is 6 gpm per square foot of resin bed surface area. If the backwash flow rate is significantly greater or less than 6 gpm per square foot, contact a softener service technician to adjust the backwash to the correct flow rate. Backwash should continue for 10-15 minutes. Record this information on the Elution Study Worksheet. 2. When backwash is complete, the softener will go into the brine cycle. Before the brine cycle begins, record the brine level in the brine tank by measuring the distance in inches from the top edge of the brine tank down to the brine surface. This measurement will be used to determine the volume of brine drawn into the softener during the brine cycle. Also, make note of the time the brine cycle begins brine draw should last for 15-20 minutes. Record the brine level measurement and the time the brine cycle starts on the Elution Study Worksheet. 3. At the beginning of the brine cycle, collect a softener effluent sample, fill the graduated cylinder with the sample, and measure the % saturation with the salimeter. The sample should measure 0% saturation at the beginning of the brine cycle. Continue sampling in this manner, taking a sample every two minutes for the duration of the study. Record sample times and % saturation measurements on the Elution Study Worksheet. 4. When brine draw stops, note the time, and measure the distance in inches from the top edge of the brine tank down to the brine surface. Compare this measurement with that taken at the beginning of the brine cycle to determine the inches of brine drawn down. The difference between the two measurements is the brine draw down. Record the inches of brine draw down and the time the brine draw stops on the Elution Study Worksheet. 5. Following brine draw, the softener will go into the slow rinse cycle. During slow rinse, continue to collect samples of the effluent every two minutes, measure the % saturation and record the results on the Worksheet. Slow rinse should continue for 30 to 45 minutes. 6. Following slow rinse, the unit will go into fast, or final rinse. The flow rate will increase to approximately that of backwash. Fast rinse should continue for 5-15 minutes. At the end of fast rinse, the % saturation should be 0. At this point, conduct a chloride test on the softener effluent; the reading should be within 15% of the chloride reading in the raw make-up water. If the chloride level in the softener effluent is more than 15% S:share\topics\technical topics\tt-35 Page 2 of 5

above the raw make-up water chloride level, the brine is not sufficiently rinsed from the softener, and the duration of the fast rinse cycle must be increased. Consult the softener operating manual or a softener service technician to increase the fast rinse cycle time. When the softener effluent chloride level is equal to that of the raw make-up, the softener effluent should contain less than 1 ppm total hardness and the softener is ready to be put into service. Using the data recorded in the Salimeter Readings table on the Softener Elution Study Worksheet, plot the salimeter readings on the Softener Elution Study Brine Curve graph. The salimeter reading line should be above the 30% mark for at least 30 minutes. This would reflect a thorough regeneration of the resin bed. Anything less than this would represent less than complete regeneration and would result in less than maximum softening capacity. If the brine curve is not at or above 30% for 30 minutes, the shape of the curve will give an indication of the problem. For example, a curve that rises sharply to peak substantially above 30% and then falls rapidly back below 30% means that the brine is being educted too quickly. In this case, the eduction water flow rate should be decreased to provide for a longer eduction time. A shallow curve that does not reach 30% of saturation indicates insufficient eduction water flow rate and/or insufficient total brine draw. S:share\topics\technical topics\tt-35 Page 3 of 5

Softener Elution Study Worksheet System Data Number of softener columns Diameter of softener column Depth of resin bed Amount of resin per column cubic feet Regeneration controlled by (check one): Timer Metered through-put Elution Study Data 1. Backwash flow rate: gpm 2. Backwash duration: minutes 3. Distance from top of brine tank to brine surface: inches 4. Time brine draw begins: 5. Time brine draw ends: Brine draw duration: minutes 6. Distance from top of brine tank to brine surface after brine draw: inches 7. Brine draw down (#6 - #3): inches 8. Volume of brine used: gallons. 9. Amount of salt used: pounds (gallons used X 2.6 for saturated brine) 10. Salt rate (pounds of salt per cubic foot of resin per column) Brine Hydrometer Readings Percent of Percent of Time saturation,nacl Time saturation, NaCl 0 0 38 minutes 2 minutes 40 minutes 4 minutes 42 minutes 6 minutes 44 minutes 8 minutes 46 minutes 10 minutes 48 minutes 12 minutes 50 minutes 14 minutes 52 minutes 16 minutes 54 minutes 18 minutes 56 minutes 20 minutes 58 minutes 22 minutes 60 minutes 24 minutes 62 minutes 26 minutes 64 minutes 28 minutes 66 minutes 30 minutes 68 minutes 32 minutes 70 minutes 34 minutes 72 minutes 36 minutes 74 minutes S:share\topics\technical topics\tt-35 Page 4 of 5

Softener Elution Study Brine Curve 50 45 40 Percent Saturation, NaCl 35 30 25 20 15 10 5 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Time, Minutes S:share\topics\technical topics\tt-35 Page 5 of 5