safety Shut-Off Valve HON 721

Similar documents
Safety Shut-Off Valve HON 720

Gas Pressure Regulator HON 300

safety shut-off Valve HON 703 / HON 704

Gas Pressure Regulator HON 502

Safety Shut-Off Valve RMG 711

Safety Relief Valve HON 835

Safety Relief Valve HON 832

Gas Pressure Regulator HON 200

Actuator HON 670 / 671

Gas Pressure Regulator HON 505

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

Pilot HON 630a, HON 640

Safety shut-off valve S 100. Product information

SSV-Actuator HON 673 (K 1a, K 2a)

Safety shut-off valve S 50. Product information

HON 219 Pressure Reducer (D119a)

SAV. Safety Shut-off Valve. Safety Shut-off Valve Type SAV

Safety shut-off valve Control Control Lock-up Over pressure set point Under pressure set point pressure range accuracy class

Safety Relief Valve RMG 835

Gas Pressure Regulator RMG 201

RR 16 Commercial & Industrial Regulator

HON HSV086 Series Safety Shut-off Valves for Efficient, Sustainable and Safe Gas Distribution. Proven Technology. Superior Performance.

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM

Norval Pressure regulator

RR 16 Commercial & Industrial Regulator

Safety Cut-Off Valve HON 305

Gas pressure regulator RS 254 / RS 255

Pressure Regulator 133 / 233

RMG 790 water Safety Shut-Off Valve

Norval Pressure Regulators

RB 4700 Commercial & Industrial Regulator

Slam Shut Valves SCN

Water Safety Shut-off Valve HON 790

Gas Pressure Regulator R 51

Cellular Gas Filters DF 100. Product Information

Gas Pressure Regulator RMG 505

CSB400 Series Commercial / Industrial Pressure Reducing Regulators

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Safety Shut-off Valve SSV

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting

Two-port valves, male threaded, PN25

Gas pressure regulator RSP 254 / RSP 255. Product information. Regulator R / R / R Actuator AS 254 / AS 255

Dival 600. Pressure Regulators

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

CSB400 Series Commercial / Industrial Pressure Reducing Regulators

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

Aperval Pressure Regulators

4/2 way Pneumatic Solenoid Valve

627 Series Pressure Reducing Regulators

2-port seat valves PN25 with externally threaded connections

Pressure Independent Control Series

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Gas Pressure Regulator HON 300

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

Overflow Regulator TYPe 92-99

OPERATING INSTRUCTIONS

Gas Pressure Regulator HON 270 MK2

Slam Shut Valves SBC 782

Gas Pressure Regulator HON 280H - 309

RB 4000 Commercial & Industrial Regulator

Diaphragm Valve, Metal

2-Port Seat Valves with Flange, PN 16

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Series 100 Slam Shut Valve. Technical Bulletin

Operation and Maintenance, Spare Parts Serving the Gas Industry - WORLDWIDE. edition 06/2005

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

2-Port Seat Valves with Flange, PN 16

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

General Catalogue MEDENUS 2018/2019

Installation, operation & maintenance manual - original version

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

General Catalogue MEDENUS

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL PRV44

Pressure and Flow Control Valves DBGM, German and European Patents

Pressure reduction controller (PN 16, 25, 40)

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

2/2-Way Solenoid Control Valve

Pressure regulator FRS

Seated valves VRB 3, VRG 3

GAS PRESSURE REGULATORS AP

Pressure Reducing Valve DMV 750

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL M2

AVP-F. p setting range (bar) Code No. 003H6200

Water. VAG DUOJET Automatic Air Valve Single-chamber type PN 10/16/25/40 - DN KAT-A 1912

Mounting and Operating Instructions EB 3009 EN. Self-operated Regulators. Type RS Check Valve (backflow protection)

Pressure regulators. Introduction. TR Head. 3 ways body Dival

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

PRESSURE REGULATOR LBM SERIES

pressure regulator Zero pressure regulator Proportional pressure regulator Compressed air-controlled

Overview of types. Technical data. Safety notes

Directional Control Valves Series VA13 and VA15 3- and 5-port valves, G1/8

SLAM-SHUT VALVES. Type BM5. Process Management TM

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified

C-Flow Coriolis Mass Flow Meters

Installation, Operation and Maintenance Manual for Back Pressure Regulator

RTG 311 pressure regulators are included within the direct acting and balanced valve regulator class.

Pressure reducing valves Index

Transcription:

safety Shut-Off Valve HON 7 product information serving the gas industry worldwide

safety shut-off valve HON 7

safety shut-off valve HON 7 Application, Characteristics, Technical Data Application safety device for gas pressure regulating stations suitable for natural gas according to DVGW G 60, other gases on request Characteristics compact design, small face-to-face dimensions low pressure drop due to valve seat diameter equal to pipe size diameter easy maintenance due to interchangeable cartridge assemblies (plug-in system) four tripping facilities; manual release as standard feature can be provided with various measuring units for different response pressure ranges electromagnetic release and remote indication of valve position as special features automatic release in case of diaphragm-fracture acc. to DIN EN 8 (DIN 8) technical data max. inlet pressure pmax 0 bar (depending on connections) sizes DN 0, DN 80, DN 00, DN 0 connection flanged to DIN PN 6, PN, PN 0 and to ANSI 0 RF and ANSI 00 RF valve seat diameter same size as flange diameter adjustment ranges (for setpoint spring ranges see page ) for overpressure release: W do 0.0 bar to 0 bar for underpressure release: W du 0.0 bar to 0 bar optional features electromagnetic release upon current pulse / current failure electric remote indication of valve position closed temperature release material main valve body measuring unit housing internal parts steel diaphragms, O-rings ductile iron / cast steel cast aluminium, aluminium forging aluminium, stainless steel, brass, rubber-like plastic material (NBR) ambient temperature class -0 C to +60 C function and strength DIN EN 8 (DIN 8) Ex-protection The device does not have any potential ignition sources and thus ATEX 9 does not apply to it (applied electronic accessories comply with the ATEX requirements). CE-sign to PED 8

safety shut-off valve HON 7 Application, Characteristics, Technical Data adjustable trip ranges setpoint spring overpressure cut-off underpressure cut-off pilot No. colour yellow wire-ø in mm. upper adjusting range W dso (bar) 0.00... 0.00 re-engagement diff. between response pressure and normal service pressure* p wo (bar) 0.00 lower adjusting range W dsu (bar) re-engagement diff. between response pressure and normal service pressure* p wu (bar) actuating pressure class** AG 0/ K0a bright red dark red white..6.8 0.080... 0.0 0.00... 0.00 0.00....00 0.00 0.00 0.0 0/ /. /. yellow.0 0.00... 0.0 0.0 6 white. 0.0... 0.00 0.00 / 7 black. 0.0... 0.0 0.060 bright green.0 0.00....00 0.0 /. yellow 6..000....000 0.00./ K bright red white 8.0.0.000... 8.000.000 0.00... 0.00 0.00./ bright blue.8 0.0... 0.800 0.00 / 6 black.6 0.00....000 0.800 / yellow 6..000....00.000./ bright red 8.0 7.000... 0.00.000./ K white.0 0.00....00 0.800 bright blue.8 0.700....00.00 / 6 black.6.00... 6.000.00 / grey 0.00... 0.0 0.00 yellow 0.0... 0.00 0.00 /. ivory 0.080... 0.00 0.00./ Ka bright red 0.0... 0.00 0.00 dark red 0.0... 0.00 0.00 6 bright lue 0.00... 0.00 0.00 7 dark blue 0.0....000 0.00 0 bright blue 0.800....00 0.00. black.000....000 0.00./ K6 grey.000... 0.00 0.00 brown.000... 0.00 0.800 red 0.00... 0.00.00 grey.000... 0.00 0.00 < K7 brown.000... 0.00 0.800 < red 0.00... 0.00.00 < *) Note: if control devices are used with both overpressure and underpressure release, then the min. gap between the two setpoints pdso and pdsu has to be at least 0% larger than the sum of the two differential values ( pwo and pwu). pdso - pdsu. ( pwo + pwu) **) The higher response precision category is valid for the first half, the lower response precision category is valid for the second half of the setting range.

safety shut-off valve HON 7 Application, Characteristics, Technical Data Diagram for determination of pressure drop and max. permissible flow velocity (natural gas ρn=0.8 kg/m) flow rate Qn in m/h 0 00 00 700 000 000 000 000 000 0000 DN 0 inlet pressure p u in bar 0, v max = 0m/s DN 00 DN 80 DN 0 0 size DN 6 0 0.0 0.0 0.0 0.0 0.07 0. 0. 0. 0. 0.7.0 pressure drop p in bar pmax = 0, bar.) determination of pressure drop This diagram is valid for natural gas. For other gases please convert the flow rate into the natural gas flow. Qn nat.gas = Qn gas f in m/h conversion factor f nitrogene 0.8 (for other conversion methane.08 factors please see town gas. Honeywell-booklet) air.6 example: given: DN 0, pu = 0 bar, Qn = 00 m/h (town gas) Qn gas 00 m/h determination of pressure drop: Qn nat. gas = = = 900 m/h f. found: (path ): p = 0.07 bar < pmax = 0. bar.) permissible gas velocity vmax. It can be determined by using the nominal flow rate. example: given: DN 0, pu = 0 bar, Qn = 00 m/h (town gas) gas velocity control: found: (path ): v < vmax = 0 m/s

safety shut-off valve HON 7 Design and Operation HON 7 with measuring unit 6 K0a measuring unit K0a setpoint spring tripping valve HON 99 ball release mechanism diaphragm measuring line connection foce redirection tripping device vent line ball- and pin arresting mechanism valve stem closing spring main valve body pressure compensating valve valve plate valve seat inlet pressure outlet pressure atmosphere push-button for re-engagement The safety shut-off valve HON 7 was designed to automatically shut off the gas flow of a gas pressure regulating station, as soon as the pressure within the system to be protected rises above or falls below preset limits. The HON 7 consists of a main valve body with the valve seat and an exchangeable functional unit for safety shut-off. This exchangeable shut-off unit comprises all functional elements, such as measuring unit, tripping device and valve plate with integrated pressure compensation valve. The functional unit can easily be removed from the main valve body by loosening the retaining screws. For regular maintenance the actuating element can easily be subjected to a visual inspection. In case of failure the actuating modules can be replaced by spare units, and the repair works can be carried out in the workshop without having to shut down the gas pressure regulating system.

safety shut-off valve HON 7 Design and Operation ball-and-pin tripping device in service position (valve open) ball-and-pin tripping device after manual release (valve is closed) manual release tripping device switching ring switching pins retaining balls measuring unit connecting rod valve rod guide bush guide bush tripping device manual release switching ring switching pins retaining balls valve rod measuring unit connecting rod 7 Measuring units K0a, K und K: As soon as the measuring diaphragm moves out of its neutral position, the ball is pressed out of the groove of the diaphragm rod. By this lateral movement the connecting rod is pushed into the tripping device and causes a turning motion of the switching ring. Measuring units Ka, K6, K7: These measuring units convey their response by exerting a pressure stroke to a piston with a connecting rod (pressure transformer) flanged to the tripping device. The motion of the rod will cause the switching ring to turn. For manual release the turning motion is effected by pressing the release button. Tripping Device: The internal part of the tripping device consists of a ball-and-pin release mechanism which is pivoted on bearings. In the service position the SSV valve plate is kept open by the valve stem being arrested within the tripping device. In the open position the valve stem rests upon the balls located in the bore holes of the guide bush. The rolls, which are located in the exterior switching ring running on bearings, are positioned in the same angle as the balls and prevent the balls from being pressed away towards the outside. If the switching ring is turned anti-clockwise, the balls can evade towards the outside so as to release the valve stem. The force of the closing spring will press the SSV valve plate into its seat and shut off the gas flow. A re-engagement button is used for valves up to DN 00. A handwheel is provided for DN 0. An initial actuation of the reengagement element will open the pressure compensation valve to establish pressure balance within the main valve body, whereupon the main valve plate can be opened without extra force and the safety shut-off valve can be reset into its service position. (Attention: Observe the re-engagement differentials as explained on page 9 of our General Operating Instructions for Gas Pressure Regulators and Safety Devices.

safety shut-off valve HON 7 Dimensions and Connections clearance for dismantling E (measuring unit) clearance for dismantling D (tripping device) breathing line clearance for dismantling E (measuring unit) clearance for dismantling D (tripping device) breathing line / vent line 8 measuring line C B measuring line on the back C B A DN 80 with K or K A DN 80 with Ka, K6 or K7 measuring unit tripping device hand wheel for re-engagement DN 0 with K0a, K, K, Ka, K6 or K7

safety shut-off valve HON 7 Dimensions, Connections and Weights dimensions in mm size face to face dimension A DN flange acc. to DIN flange acc. to and ANSI 0 RF ANSI 00 RF 0 80 98 8 00 68 0 7 SSV with measuring unit K0a Ka K K K6 K7 K0a Ka K K K6 K7 K0a Ka K K K6 K7 K0a Ka K K K6 K7 total total clearance for dismantling height height D E B C tripping device measuring unit 0 70 60 600 60 70 60 0 60 70 60 0 90 70 00 90 670 9 90 670 90 70 00 90 670 9 90 670 80 90 700 6 80 90 60 00 80 60 660 9 connections measuring lines for measuring units: K0a, K, K, Ka threaded connection for tube x, connection thread M 6 x, measuring lines for measuring units: K6, K7 threaded connection for tube x, connection thread M x, breathing lines threaded connection for tube x, connection thread G / weights size DN weight in kg 0 9 80 00 0 0

safety shut-off valve HON 7 Specification example HON 7-0 - K / E / HA / F - So 0 body size size body with accessoires* DN material EN-GJS00-8-LT flanges acc. to material GSMnN flanges acc. to PN 6 PN 6 ANSI 0 RF PN /0 ANSI 00 RF 0 80 00 0-00087 00087-00086 00086 000867 00087 00086 000866 000869 000878 00086 00086 000868 000876 000 00 00 00 Type size SSV-measuring unit electro magnetic release manual release electric remote control of valve position closed special feature measuring unit size setting range in bar measuring DN upper cutoff W do lower cutoff W du unit 0.00....000 - Ka 0, 0.00....00 0.00... 0.0 K0a 80, 0.00... 8.000 0.00....000 K 00,.000... 0.00 0.00... 6.000 K 0 0.800... 0.00 - K6 -.000... 0.00 K7 accessories release by current supply E release by current drop E manual release HA remote indication of valve position closed F special feature (to be specified in detail) special feature So *) These Honeywell-part numbers are plotted to the identification plate

safety shut-off valve HON 7

For More Information To learn more about Honeywell s Advanced Gas Solutions, visit www.honeywellprocess.com or contact your Honeywell account manager GERMANY Honeywell Process Solutions Honeywell Gas Technologies GmbH Osterholzstrasse Kassel, Deutschland Tel: +9 (0)6 007-0 Fax: +9 (0)6 007-07 HON 7.00 07-0 07 Honeywell International Inc.