SENSOR SELECTION GUIDE

Similar documents
Technical Manual. Sensepoint XCD Gas Detector

Applications Note: Use of "pentane equivalent" calibration gas mixtures

Guide to Gases and Vapours

MINIRAE 2000 & MULTIRAE PRE-PROGRAMMED COMPOUND LIBRARIES

Operation and Maintenance Manual

DETCON, Inc Technology Forest Blvd. Suite 100, The Woodlands, Texas Ph / Fax

Misuse of Combustible Gas Meters

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

Calibration Requirements for Direct Reading Confined Space Gas Detectors

Atmospheric Hazards. Hazardous Atmosphere 3/29/2017. Oxygen deficiency and enrichment Flammable gases and vapors Toxic contaminants

PRECISION GAS MIXTURES

Phosgene Sensor. Sensoric COCl2 3E 1

Calibration and Bump Test Requirements for Direct Reading Portable Gas Monitors

GAS DETECTION: CALIBRATION GAS

Gas monitoring using GASMET FTIR

USER'S MANUAL HOT-WIRE TYPE GAS SENSOR NAP-100A SERIES ( NET10A(R) ) (For All Combustible Gases)

Receiving Cylinders and Containers

Verification Of Calibration for Direct-Reading Portable Gas Monitors

Describe Flammable Gas Measurement

O3 3E 1 F Gas Sensor Module

Use of Hazardous Gases Standard Operating Procedure

Carnegie Mellon University. Toxic and Highly Toxic Gas Handling Program

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

STORAGE AND USE OF HIGH HAZARD GAS

Recent changes in the rules for confined space entry

Continuous gas analysis ULTRAMAT 23 Supplement 2 for Operating Instructions C79000-G52xx- C216-03

Lecture Bottles Purchase & Disposal

Operation and Maintenance Manual

It is widely accepted that what you

Dangerous Gas Standard

SENSOR MANUAL Document No M (Revision L)

Gas Mixture Two Components. Gas Mixtures Two Components

Air Check Lite Toxic Gas Monitor

Gas Detection. Portable Gas Detection for Safety in Confined Spaces

Flammability Chart. Gas Formula Ignition

MODEL GT820 OXYGEN SENSOR

360 SERIES Flammable Gas Sensor / Transmitter

Calibration Gases. Intrial provides mix of special calibration gases for analyzers and detectors.

Instrumental Technique GAS CYLINDER

NIOSH Flowback Study. William G. Burket, CFPS

Calibration Gases. Intrial provides mix of special calibration gases for analyzers and detectors.

Workplace Safety and Health (Major Hazard Installations) Regulations 2017 S 202/2017

Compressed Gas ER Fundamentals

Ultima. X Series Gas Monitor

A12-17 Combustible Gas Transmitter

Safe Method of Use 9 HSNO Class 2 Gases

SPECIFICATION. date of manufacture. Intermittent: -20 o C to +50 o C. Pressure Range:

SPECIFICATION. date of manufacture. Intermittent: -20 o C to +50 o C. Pressure Range:

order-no: / 13 Kunden-Nummer Kunden-Name Aktualisierungsdatum checked (140/140) 1, 2-dichloroethane

analytical bulk flow distance FLOW level pressure temperature industrial communication

Entry to these spaces must be rigorously controlled to prevent serious injury or death.

Introduction to Confined Space Safety OR-OSHA

1. Compute the TWA for the following respirable dust exposures:

Technical Data Sheet MF010-O-LC

OP08 - Electrochemical 3-Electrode Un-biased Toxic Sensors CONTENTS. Introduction 2. Operating Principles 2. Recommended Circuitry 4.

Spot the Hazards: Review Confined Space Hazards Missed by Most Safety Professionals, and the PPE Solutions that Meet OSHA Requirements

Calibrate or Die! Calibration Types

Department of Physics Standard Operating Procedures (SOP) Approved by: Physics Safety Committee

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

an ISO9001 company TECHNICAL INFORMATION FOR TGS5141 Technical Information for Carbon Monoxide Sensors

Oxygen & Binary Gas Measurement and Analysis

H 2. Specific gravity. Material

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Noxious Fumes and Gases

An Introduction To Gas Detection

1.2.7 Hazard Communication

HIGH ACCURACY MULTI-GAS MONITORING USING AUTOMATED SELF- CALIBRATION

CC Operation Manual Oak Valley Drive, Suite 20, Ann Arbor, Michigan USA fax

Gas-Detection Instruments

AMMONIA REFRIGERATION IN WAREHOUSES

Operating Characteristics and Handling Manual for the NAP-55A / NAP-50A Explosive/Flammable Gas Sensor NEMOTO

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

Columbus Instruments

HLM-2000-EX Flammable Gas Transmitter User Manual

Online DGA-monitoring of power transformers

Confined Space Entry - Permits

CALCULATING THE SPEED OF SOUND IN NATURAL GAS USING AGA REPORT NO Walnut Lake Rd th Street Houston TX Garner, IA 50438

Gas Metrology. SI-traceable: Primary Reference Materials Certified Reference Materials Calibrated Gas Mixtures Interlaboratory Comparisons

HC/LEL Sensor Addendum to Reference Manual Cannonball 3 Multi Gas Detector

Nonrefillable Cylinders

FLAMMABLE GAS SENSOR/TRANSMITTER

acrolein, acetaldehyde and acetone( cm -1 ); methanol (1306 cm -1 ); ethylene (949 cm -1 ); and isoprene (893 cm -1 ).

When is the air clean?

All Sixth Sense cells for toxic gas detection are based on electrochemical principles and can be classified as amperometric fuel cells.

Using Vaporized Hydrogen Peroxide

1000 Series. Quality. Superior Filter Media. SABS Quality Mark. Metal Nose Clip. Foldable. Made in South Africa. Comfort Valve. Usage: Application:

M a t e r i a l S a f e t y D a t a S h e e t

METHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS. 1.2 Scope. This method is applicable for the

an ISO9001 company TECHNICAL INFORMATION FOR TGS5042 Technical Information for Carbon Monoxide Sensors

MD61 Thermal Conductor Gas Sensor

The Following information is based on material prepared by the American Lung Association

Ozone. Sensoric O3 3E 1

Antaris IGS Gas Analyzer

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Working in Gas Hazard Areas

MEMS VOC Gas Sensor. (Model No.:GM-503A) Manual. Version: 1.0. Valid from: Zhengzhou Winsen Electronics Technology Co.

Instructions. To complete this independent study program, view the entire program, advancing through each slide by pressing the enter key.

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

Generating Calibration Gas Standards

Transcription:

SENSOR SELECTION GUIDE TOXIC AND COMBUSTIBLE GAS MONITORS (Includes gas listings with TLV-TWA, STEL, IDLH, LEL, and UEL for most gases) INTERNATIONAL SENSOR TECHNOLOGY The Leader In Gas Detection Since 1972 3 Whatney Irvine, California 92718-2806 Telephone 949-452-9000 FAX: 949-452-9009 TLX: 4722070

TABLE OF CONTENTS 1. Introduction... 1 2. Solid State Sensors... 1 2.1 General 2.2 Principle of Operation 2.3 Characteristics 3. Catalytic Bead Sensors... 2 3.1 General 3.2 Principle of Operation 3.3 Characteristics 4. Electrochemical Sensors... 3 4.1 General 4.2 Principle of Operation 4.3 Characteristics 5. Sensor Selection... 4 5.1 Combustible Gas Monitoring 5.2 Toxic Gas Monitoring 5.2.1 Carbon Monoxide 5.2.2 Hydrogen Sulfide 5.2.3 Chlorine/Hydrogen Chlorine 5.2.4 Ammonia 6. Sensor Installation Notes... 6 7. Definitions 6 8. Solid State Sensor Gas Data... 7 9. Product Data... 9 9.1 Stationary Instruments 9.1.1 Transmitters SM95 4-20 IQ 9.1.2 Conventional Systems MP Series 9.1.3 Computerized Systems Remote-Link System 9.2 Portable Instruments 9.2.1 Single Gas IQ250/IQ350 9.2.2 Multi-Gas IQ1000 IQ200

1. INTRODUCTION The detection of hazardous gases has always been a complex subject, making the choice of an appropriate gas monitoring instrument a difficult task. International Sensor Technology (IST) has been providing gas detection equipment to customers worldwide since 1972. Through this experience we have compiled this guide which will provide you with some insight into the various sensing methods used for gas detection and provide you with information about the different instruments available to you. It will help you to make an informed decision concerning which sensor type and which instrument is best suited to your particular application. Discussion of sensing methods will focus on the following three sensor types: Solid State, Electrochemical, and Catalytic Bead. These are the most suitable and widely used sensors for ambient air monitoring, and all three of these types are available from IST. It should be noted that instruments utilizing these sensors are not intended for use as analytical laboratory devices. The readings provided by these sensors should be used primarily as indicators of whether an area is safe or not, much like a smoke detector. While these sensors are much more refined than smoke detectors, they are nonetheless subject to erroneous readings from interference gases and lack of periodic calibration, among other things. However, as long as these limitations are understood, the sensors will provide meaningful data and are a valuable tool for ambient air monitoring. Instruments using these sensors will respond quickly in the presence of gas, enabling alarms to be triggered and allowing personnel to take appropriate action. In addition, they are generally easy to use, require little maintenance, and are economically priced. To date, no gas sensors exist which are 100% selective to a single gas. Achieving selectivity requires the use of an analytical instrument. Various analytical techniques have been employed for gas detection and find use in certain applications. Examples of such instruments include Fourier Transform Infrared (FTIR) analyzers, Gas Chromatographs, and Mass Spectrometers. These instruments can provide fairly accurate and selective gas readings. However, they are generally very expensive and, in addition, many suffer from limitations such as high maintenance, slow response time, large size, and difficulty of use, making them impractical for use as ambient air monitors. As ambient air monitors, they are typically used only as a last resort for applications in which a suitable sensor is not available. 2. SOLID STATE SENSORS 2.1 GENERAL I H A B +V S COLLECTOR TO D (SENSOR SURFACE TEMP.) Figure 1. Solid State Sensor V OUT Solid state sensors were introduced in the 1970 s and represented a major breakthrough in the field of ambient air monitoring. They are unique in the fact that they can detect both toxic and explosive gases, in concentrations as low as several ppm or as high as 100% LEL and above. Today, solid state sensors are available for the detection of over 150 different gases, including many which could otherwise only be detected using expensive analytical instruments. An added advantage of solid state sensors is that they have a long life expectancy, typically 10 years or more, and come with a three year warranty. They are also quite rugged they can take occasional exposure to high gas concentrations without damage and are not poisoned by substances which often harm other sensor types. Many IST solid state sensors installed in the 1970 s are still in operation today. 1

2.2 PRINCIPLE OF OPERATION A solid state sensor consists of two electrodes embedded into a solid state metal oxide material. The presence of gas changes the resistance of the material, with the magnitude of change directly related to the gas concentration. The resistance change, and hence the gas concentration, is measured through the sensor s corresponding electronic circuitry. The sensor is kept at a specific operating temperature by applying a heater voltage to it. The choice of heater voltage is critical in determining the response characteristics of the sensor. By varying this voltage and by using different materials and processing techniques, sensors can be made which are more sensitive to one gas or group of gases and less sensitive to others. 2.3 CHARACTERISTICS Gases Detected: Refer to Solid State Sensor Gas Data table. Calibration Interval: 30 days to 6 months, depending on the application. Expected Sensor Life: 10 years or more. Comes with a 3 year warranty. Environmental: Temperature: -40 to +60 C -40 to +140 F Humidity: 10% - 95%, non-condensing. 3. CATALYTIC BEAD SENSORS 3.1 GENERAL Catalytic bead sensors find use in applications requiring the detection of combustible gases where toxicity is of no concern. They only respond well to the higher gas concentrations, from 1000 ppm up to % LEL levels. Catalytic bead sensors are non-specific, and will respond to a wide variety of combustibles. The quality and performance of a catalytic bead sensor can vary from one manufacturer to another. Historically, catalytic bead sensors have been known to be susceptible to poisoning from H2S, silicones, and other substances. However, recent developments have led to the introduction of catalytic bead sensors which are poison resistant. Among these is IST s Catalytic Sensor. In addition to being poison resistant, these and other well-made catalytic bead sensors will provide good stability and a long life expectancy. 3.2 PRINCIPLE OF OPERATION A catalytic bead sensor consists of an active element and a reference element. At the heart of each of the elements is a heated platinum coil whose resistance varies with temperature. As long as both elements are at the same temperature, their resistances will be equal. In the presence of gas, however, the active element will burn the gas on its surface, raising the temperature of the platinum coil, while the reference element will show no response to the gas. Hence, a differential is created in the resistances of the two elements. When both elements are placed in a Wheatstone bridge circuit, this differential acts to throw the bridge out of balance, producing a signal which is proportional to the gas concentration. Because catalytic sensors operate on the combustion principle, they must be used in environments containing oxygen. 3.3 CHARACTERISTICS Gases Detected: Calibration Interval: Expected Sensor Life: Environmental: Temperature: OUTPUT Active Bead Reference Bead R B R B R 1 Figure 2. Catalytic Bead Sensor Combustible gases in % LEL ranges. Depends on application 1 month is typical. 2 years typical. Comes with a 1 year warranty. -40 to +75 C -40 to +167 F Humidity: 0-99%, non-condensing. D.C. POWER 2

Capillary Diffusion Barrier Membrane 4. ELECTROCHEMICAL SENSORS Sensing Electrode Reference Electrode 4.1 GENERAL The oldest electrochemical sensors, used for O2 monitoring, date back to the 1950 s. Today, electrochemical sensors are available for the detection of about a dozen toxic gases in ppm ranges, including CO, H2S, and NH3. For some gases, electrochemical sensors can exhibit fairly good sensitivity and selectivity and therefore are a popular choice for certain applications. They have an added advantage in that they require low power to operate. However, dryout of the electrolyte used in these sensors can result in a reduced life, and the sensor is also subject to poisoning which can lead to the need for frequent calibration, premature drift, and sensor failure. These sensors also should not be exposed to high gas concentrations for long periods of time, as this will dramatically reduce their useful life. 4.2 PRINCIPLE OF OPERATION Electrochemical sensors operate by reacting with the gas of interest and producing a signal proportional to the gas concentration. A typical electrochemical sensor consists of a sensing electrode, a counter electrode, and a reference electrode separated by a thin layer of electrolyte. Gas which comes in contact with the sensor first passes through a diffusion barrier, which is designed to limit the amount of gas entering the sensor. Gas diffusing through the barrier reacts at the surface of the sensing electrode by either oxidation or reduction. Reactions are catalyzed by electrode materials specially developed for the gas of interest. As an example, for a Carbon Monoxide Sensor, the gas would react at the sensing electrode according to the following equation: CO + H 2 O CO 2 + 2H + + 2e-. Similarly, electrochemical sensors for other gases would produce reactions based on the gas they are designed to detect. Selectivity can be achieved through the choice of the electrode material, electrolyte, operating voltage, and through selective filtration. 4.3 CHARACTERISTICS Gases Detected: Following is a partial list of typical gases and ranges available for detection using electrochemical sensors. Other gases/ranges are also available. GAS FORMULA TYPICAL RANGES (in PPM except O 2) Ammonia NH 3 50 Carbon Monoxide CO 20, 50, 100, 200, 300, 500, 1000, 2000, 3000, 4000,10000, 20000, 40000 Chlorine Cl 2 5, 10, 20, 30, 50, 100, 200, Hydrogen H 2 50, 200, 300, 500, 1000, 2000, 20000, 30000, 50000 Hydrogen Chloride HCl 5, 10, 20, 30, 50, 100, 200 Hydrogen Cyanide HCN 100 Hydrogen Sulfide H 2S 5, 10, 20, 30, 50, 100, 200, 300 Nitric Oxide NO 10, 20, 30, 50, 100, 200, 300, 500, 1000, 2000 Nitrogen Dioxide NO 2 5, 10, 20, 30, 50, 100, 200, 300 Oxygen O 2 0-25%, 0-30% Oxygen Sulfur Dioxide SO 2 5, 10, 20, 30, 50, 100, 200, 300, 500,1000, 2000 Calibration Interval: Figure 3. Electrochemical Sensor Expected Sensor Life: Environmental: Temperature: 1-2 times per month typical. 1-2 years typical. -5 to +40 C +23 to +104 F Continuous. -15 to +50 C +5 to +122 F Intermittent. Humidity: 15 to 90% non-condensing Continuous. 0 to 99% non-condensing Intermittent. Counter Electrode Electrolyte 3

5. SENSOR SELECTION Gas monitoring generally consists of two categories: Toxic Gas monitoring and Combustible Gas monitoring. In actuality, many gases are both toxic and combustible. Carbon monoxide, for example, has a TLV of 25 ppm and also has a Lower Explosive Limit (LEL) of 12.5% by volume, or 125,000 ppm. Thus, it is the concentration range of the gas to be monitored which determines whether the monitoring fits into the category of toxic or combustible. Toxic gases are normally associated with low gas concentrations in the ppm range, while combustible gases are associated with high gas concentrations in the %LEL range. For monitoring toxic gases, either a solid state or, where available, an electrochemical sensor can be used. For monitoring combustible gases, either a solid state or catalytic bead sensor can be used. This section will present a comparison of these sensor types to help you determine which sensor may be best for your particular application. As mentioned previously, when using any of these sensors, it is important to remember that they will not be 100% specific to the gas of interest. Depending on the gas to be monitored and the sensor type chosen, you may encounter varying degrees of interference from other gases which are present in your environment. Additionally, for toxic gases especially, the choice of the appropriate concentration range to monitor is very important. For example, if you are monitoring to protect workers from toxic gases, typically a full scale range of 3 to 10 times the TLV of the gas being monitored is chosen. It is important to remember that the TLV for a gas is defined as a SAFE level which workers can be exposed to for the entire work day. Thus, it is wise to choose a full scale range which is higher than the TLV to enable you to set alarm points at concentration ranges above the TLV, where the gas levels are hazardous. For combustible monitoring, a range of 100% LEL is typically chosen, and other ranges are available. 5.1 COMBUSTIBLE GAS MONITORING For combustible gas monitoring, either a solid state or catalytic bead sensor can be used. Solid state sensors are rugged and have a long life expectancy. It is not uncommon for a solid state sensor to operate for 10 years or more without needing replacement. They are resistant to poisoning and can take occasional exposure to high gas concentrations without damage. Catalytic bead sensors are also quite rugged. As mentioned earlier, several manufacturers now offer catalytic bead sensors which are poison resistant. Additionally, the typical life expectancy has been improved to two years. One of the main differences between catalytic bead and solid state sensors is that solid state sensors tend to be more sensitive. Catalytic bead sensors are only sensitive to combustible gases in high concentrations and will not see any concentration lower than about 1000 ppm. If the user does not indicate a specific gas to calibrate to, they are typically calibrated to methane, and because of this they are less sensitive to most other combustibles. As a result, they are less likely to produce a reading than a solid state sensor exposed to the same gases. In some instances, this characteristic can make them more practical, as they are less likely to produce spurious alarms due to interference gases. This is advantageous in situations where the user wants to detect only one particular combustible gas, and doesn t want other lower level combustibles which may also be present to be detected. The choice between the two sensors therefore involves two major considerations: life expectancy and interferences. If interference gases are not a problem in your application, then a solid state sensor is usually the best choice. It will likely perform better than a catalytic bead sensor in applications where multiple combustible gases are present and the user wants to detect all of them. It will also provide years of trouble free operation and save on sensor replacement costs. However, in applications where interference gases present a problem, the catalytic bead sensor may be the way to go. It still has a fairly good life expectancy and will be more selective than the solid state sensor. 5.2 TOXIC GAS MONITORING For toxic gas monitoring, the two sensors which can be used are solid state or electrochemical. Solid state sensors are available to detect over 150 toxic gases, while electrochemical sensors exist for approximately 15 to 20. As a result, for a large majority of gases, the choice of sensors is limited to solid state. Thus, in comparing the two sensors, the discussion only applies to those gases detected by electrochemical sensors. 4

One of the major differences between the sensors is the life expectancy. While solid state sensors have a long, predictable life expectancy, a typical electrochemical sensor lasts only one or two years, and sometimes much less. Additionally, it is important to note that not all electrochemical sensors are the same and the life expectancy of the sensors can vary greatly depending on the gas being monitored. For example, while a CO sensor will typically last over a year, a comparable ammonia sensor periodically exposed to even relatively small amounts of gas will have a much shorter life. H2S The response characteristics of both solid state and electrochemical sensors can vary depending on which toxic gas is being monitored. Therefore, the comparison of the two sensors must be done on a gas by gas basis. Following are some general points about the two sensors for various gases: 5.2.1 Carbon Monoxide Both the solid state and electrochemical sensors for CO utilize charcoal filters to block interference gases and as a result both are fairly selective. Because of the long life of the solid state sensor, it is made so that the charcoal filter can be replaced without replacing the sensor itself. The charcoal filter on an electrochemical sensor is not replaceable. 5.2.2 Hydrogen Sulfide For H2S, the solid state sensor performs very well with excellent response and selectivity. For H2S applications, it is generally recommended to use a solid state sensor because these applications tend to be in hostile environments, where a solid state sensor will fare much better than an electrochemical sensor. While electrochemical sensors will respond well on a short term basis, they ultimately do not survive long and require replacement too frequently. As a result, they should not be used in systems with large numbers of sensors, as the replacement costs of the sensors will be extremely high. A better application for them is in portable instruments, where they are not constantly exposed to the harsh environment. Even under these conditions, though, the sensor will require periodic replacement. 5.2.3 Chlorine/Hydrogen Chloride These gases are very active and corrosive, and regardless of whether a solid state or electrochemical sensor is used, the monitoring of these gases is very difficult. Monitoring ranges are typically low, and because the gases are so active, it becomes virtually impossible to prepare an accurate calibration mixture with confidence. NH3 The readings of solid state sensors for CO can be affected by humidity. Specifically, in very low humidity, they tend to read low and as a result it becomes important to add moisture to the sample whenever calibrating the sensor using a compressed gas bottle. Without doing so, the sensor may be improperly calibrated and give inaccurate readings. Humidity does not have this affect on the electrochemical sensor and therefore it may produce more stable readings overall. In the long term, though, these sensors will require more frequent replacement and will need more frequent calibration than a solid state sensor, and these factors should all be weighed when choosing between the sensors. Solid state sensors used in these applications tend to be sensitive and read upscale. As a result, they sometimes have problems with false alarms. On the other hand, electrochemical sensors tend to lose sensitivity quickly in this environment and therefore need to be checked frequently for proper operation. They can provide a false sense of security by showing low or zero readings when, in fact, the sensor is simply insensitive. 5.2.4 Ammonia CO Electrochemical sensors for ammonia have a very short life span. The sensor s life is dramatically reduced from exposure to gas, even in low concentrations. Solid state sensors are therefore a much better choice for ammonia applications. They perform well over a long period of time and have been used extensively in refrigeration applications. 5

6. SENSOR INSTALLATION NOTES There are no set rules regarding where sensors must be located, however the judgment of trained personnel and good common sense should always be used. Sensors which are properly installed can save hours of maintenance and provide trouble free operation. Following are some guidelines for installing sensors: 1. In order to select meaningful sensor locations, a specific objective should be defined. Study the building or plant layout to determine the location of various equipment, machinery, control valves, doors, vents, etc. as well as the general air flow pattern. Observe locations where gas is likely to leak from or accumulate. Generally, sensors should be located where they will indicate an average reading of the area in which the sensor is to cover. 2. It is recommended that sensors be mounted approximately 5 or 6 feet from the ground to enable easy access for maintenance and calibration. Also, avoid installing sensors too close to walls or the floor. These surfaces can absorb and emit gases with changes in temperature, affecting the reading of the sensor. At least 6 of clearance from any surface should be provided. 3. Gases have different densities, and some are lighter than air while others are heavier. However, this does not mean that sensors should be installed on the floor or ceiling to monitor these gases. Gases disperse easily and develop a concentration gradient, which means, for example, that a gas which is heavier than air will still be detected several feet off the ground. An important point to remember is that sensors must be accessible for calibration and maintenance, so installing them on the floor or ceiling is normally not a good idea. 4. In areas of new construction, sensors should be installed after operations such as sandblasting, painting, welding, etc. are completed. During such operations, sensors present should be protected by using a sensor plug, such as IST s P/N F44-P which installs over the rainshield. Remember that the sensor will not be operative with the plug installed, so remember to remove the plug when reactivating the instrument. 5. Don t install the sensor near sources of steam. Steam will damage the sensor. 6. Don t install sensors next to sources which are constantly leaking gas. 7. The number of sensors required for an application depends on a number of factors, including the plant layout, air flow pattern, type of gas to be monitored, and the degree of protection required. Choosing the proper number of sensors is a matter of common sense. Gas sensors are similar to smoke detectors, meaning they will only detect gas which directly comes in contact with the sensor. Thus, the sensor relies on the dispersion of the gas in order to detect it. 7. DEFINITIONS 1. Threshold Limit Values (TLV s): TLV s represent conditions under which nearly all workers may be repeatedly exposed day after day without adverse health effects. The accuracy of these TLV s, issued by the American Conference of Governmental Industrial Hygienists (ACGIH), are subject to variation and the latest TLV Documentation should be consulted. The categories of Threshold Limit Values (TLV s) are defined as follows: A. Threshold Limit Value - Time-Weighted Average (TLV- TWA): These values represent the time-weighted average concentrations of substances to which nearly all workers may be repeatedly exposed for a normal 8-hour workday and a 40-hour workweek, day after day, without adverse effect. B. Threshold Limit Value Short-Term Exposure Limit (TLV-STEL): STEL is defined as a 15-minute TWA exposure which should not be exceeded at any time during a workday even if the 8- hour TWA is within the TLV-TWA. Exposures above the TLV-TWA up to the STEL should not be longer than 15 minutes and should not occur more than four times per day. 2. Immediately Dangerous to Life or Health (IDLH): IDLH concentrations represent the maximum concentrations from which one could escape within 30 minutes without a respirator, in the event of respirator failure, without experiencing any escape-impairing (e.g., severe eye irritation) or irreversible health effects. These values are obtained from NIOSH: Pocket Guide to Chemical Hazards, 1990 Edition. 3. Flammable (Explosive) Limits Lower Explosive Level (LEL) and Upper Explosive Level (UEL): LEL and UEL are usually expressed as percent by volume of the material in air (or other oxidant). A substance below the Lower Explosive Level (LEL) is too lean to burn, while a substance above the Upper Explosive Level is too rich to burn. These values are obtained from NFPA 325M - Fire Hazard Properties of Flammable Liquids, Gases, and Volatile Solids, 1991 Edition. 4. Parts Per Million (PPM) and Percent By Volume: PPM and Percent By Volume are volumetric units of measurement commonly used in gas monitoring. For instance, one PPM of Hydrogen Sulfide in ambient air would mean that there is one part of hydrogen sulfide for every million parts of air. One Percent By Volume equals 10,000 PPM (1 % by Volume = 10,000 PPM). 6

8. SOLID STATE SENSOR GAS DATA The following gases are available for detection using IST s Solid State Sensors. The full-scale ranges listed are standard ranges available. For toxic gas monitoring, ranges are typically chosen which are higher than the TLV so that hazardous levels will be detected (TLV is defined as a SAFE level). For combustible gases, the typical range is 0-100 % LEL. Other ranges can also be provided please contact IST for information. The following information is valid as of 3/95. GAS TLV-TWA STEL IDLH LEL UEL FULL-SCALE RANGES Acetic Acid 10 ppm 15 ppm 1000 ppm 4% 19.9% 100, 200 ppm Acetone 750 ppm 1000 ppm 20,000 ppm 2.5% 12.8% 100, 200, 500, 1000, 5000 ppm, % LEL Acetonitrile 40 ppm 60 ppm 4000 ppm 3% 16% 100 ppm Acetylene 2.5% 100% 50 ppm, % LEL, 3% by Volume Acrolein (Acrylaldehyde) 0.1 ppm 0.3 ppm 5 ppm 2.8% 31% 50 ppm Acrylic Acid 2 ppm 2.4% 8% 100 ppm Acrylonitrile 2 ppm 500 ppm 3% 17% 50, 60, 80, 100, 200, 500 ppm, % LEL Allyl Alcohol 2 ppm 4 ppm 150 ppm 2.5% 18% % LEL Allyl Chloride 1 ppm 2 ppm 300 ppm 2.9% 11.1% 200 ppm Ammonia 25 ppm 35 ppm 500 ppm 15% 28% 50, 70, 75, 100, 150, 200, 300, 400, 500, 1000, 2000, 2500, 4000, 5000 ppm, 1%, 2%, 10% by Vol., 10%, 25%, 100% LEL Anisole 100 ppm Arsenic Pentafluoride 5 ppm Arsine 0.05 ppm 6 ppm 1, 10 ppm Benzene 10 ppm 3000 ppm 1.2% 7.8% 50, 75, 100, 1000 ppm, % LEL Biphenyl 0.2 ppm 0.6% 5.8% 50%, 100% LEL Boron Trichloride 500 ppm Boron Trifluoride 100 ppm 500 ppm Bromine 0.1 ppm 0.2 ppm 10 ppm 20 ppm Butadiene 2 ppm 20,000 ppm 2% 12% 50, 100, 3000 ppm, % LEL Butane 800 ppm 1.9% 8.5% 400, 1000 ppm, 100%, 200% LEL Butanol 8000 ppm 1.4% 11.2% 1000 ppm, 100% LEL Butene 1.6% 10% 100% LEL Butyl Acetate 200 ppm 10,000 ppm 1.7% 7.6% 100 ppm, % LEL Carbon Disulfide 10 ppm 500 ppm 1.3% 50% 50, 60, 100 ppm, 5% by Volume Carbon Monoxide 25 ppm 1500 ppm 12.5% 74% 50, 100, 150, 200, 250, 300, 500, 1000, 3000, 5000 ppm, 3%, 5% by Volume, % LEL Carbon Tetrachloride 5 ppm 10 ppm 300 ppm 50, 100, 10000 ppm Cellosolve Acetate 100 ppm Chlorine 0.5 ppm 1 ppm 30 ppm 10, 20, 50, 100, 200 ppm Chlorine Dioxide 0.1 ppm 0.3 ppm 10 ppm 10, 20 ppm Chlorobutadiene 10 ppm 4% 20% 100% LEL Chloroethanol 4.9% 15.9% 200 ppm Chloroform 10 ppm 1000 ppm 50, 100, 200 ppm Chlorotrifluoroethylene 8.4% 16% 100% LEL Cumene 50 ppm 8000 ppm 0.9% 6.5% 100% LEL Cyanogen Chloride 20 ppm Cyclohexane 300 ppm 10,000 ppm 1.3% 8% 100 ppm, 100% LEL Cyclopentane 600 ppm 1.5% 50 ppm Deuterium 5% 75% 50%, 100% LEL Diborane 0.1 ppm 40 ppm 0.8% 88% 10, 50 ppm Dibromoethane 50 ppm Dibutylamine 1.1% 100% LEL Dichlorobutene 0.005 ppm 1% by Volume Dichloroethane (EDC) 10 ppm 4000 ppm 5.4% 11.4% 50, 100 ppm, % LEL Dichlorofluoroethane 100, 1000 ppm Dichloropentadiene 50 ppm Dichlorosilane 4.1% 99% 50, 100 ppm Diesel Fuel 50 ppm, 100% LEL Diethyl Benzene 0.7% 6% 100% LEL Diethyl Sulfide 10 ppm Difluorochloroethane 6.2% 17.9% 100% LEL Difluoroethane (152A) 100% LEL Dimethyl Ether 3.4% 27% 100% LEL Dimethylamine (DMA) 5 ppm 15 ppm 2000 ppm 2.8% 14.4% 30, 50 ppm Epichlorohydrin 2 ppm 250 ppm 3.8% 21% 50, 100, 500, 1000 ppm Ethane 3% 12.5% 1000 ppm Ethanol 1000 ppm 3.3% 19% 200, 1000, 2000 ppm, % LEL Ethyl Acetate 400 ppm 10,000 ppm 2% 11.5% 200, 1000 ppm, % LEL Ethyl Benzene 100 ppm 125 ppm 2000 ppm 0.8% 6.7% 200 ppm, % LEL Ethyl Chloride 1000 ppm 20,000 ppm 3.8% 15.4% 100 ppm, % LEL Ethyl Chlorocarbonate 1% by Volume Ethyl Ether 19,000 ppm 100, 800, 1000 ppm, % LEL Ethylene 2.7% 36% 100, 1000, 1200 ppm, % LEL Ethylene Oxide 1 ppm 800 ppm 3% 100% 5, 10, 20, 30, 50, 75, 100, 150, 200, 300, 1000, 1500, 2000, 3000 ppm, % LEL Fluorine 1 ppm 2 ppm 25 ppm 20, 100 ppm Formaldehyde 30 ppm 7.3% 7% 15, 50, 100, 500, 1000 ppm Freon-11 1000 ppm 10,000 ppm 1000, 2000, 5000 ppm Freon-12 1000 ppm 50,000 ppm 1000, 2000, 3000 ppm Freon-22 100, 200, 500, 1000, 2000 ppm Freon-113 1000 ppm 1250 ppm 4500 ppm 100, 200, 500, 1000, 2000 ppm, 1% by Vol. Freon-114 1000 ppm 50,000 ppm 1000, 2000, 20000 ppm Freon-123 1000 ppm Fuel Oil or Kerosene 0.7% 5% 100% LEL Gasoline 300 ppm 500 ppm 1.3% 7.1% 100, 1000, 2000, 20000 ppm., % LEL Germane 10, 50 ppm Heptane 400 ppm 500 ppm 5000 ppm 1.05% 6.7% 1000 ppm, % LEL 7

SOLID STATE SENSOR GAS DATA The following gases are available for detection using IST s Solid State Sensors. The full-scale ranges listed are standard ranges available. For toxic gas monitoring, ranges are typically chosen which are higher than the TLV so that hazardous levels will be detected (TLV is defined as a SAFE level). For combustible gases, the typical range is 0-100 % LEL. Other ranges can also be provided please contact IST for information. The following information is valid as of 3/95. GAS TLV-TWA STEL IDLH LEL UEL FULL-SCALE RANGES Hexane 50 ppm 5000 ppm 1.1% 7.5% 50, 100, 200, 2000, 2500, 3000 ppm, % LEL Hexene % LEL Hydrazine 0.1 ppm 80 ppm 2.9% 9.8% 5, 10, 20, 100, 1000 ppm, 1% by Volume Hydrogen 4% 75% 50, 100, 200, 500, 1000, 2000, 5000 ppm, 3%, 5% by Vol., 2% to 100% LEL Hydrogen Bromide 3 ppm 50 ppm 50 ppm Hydrogen Chloride 5 ppm 100 ppm 50, 100, 200, 400, 500, 1000 ppm Hydrogen Cyanide 4.7 ppm 50 ppm 5.6% 40% 20, 30, 50, 100, 200, 1000, 10000 ppm Hydrogen Fluoride 30 ppm 20, 50, 100, 200 ppm Hydrogen Sulfide 10 ppm 15 ppm 300 ppm 4% 44% 5, 10, 20, 30, 50, 100, 300, 1000 ppm, % LEL Isobutane 1.8% 8.4% 1000, 3000 ppm, % LEL Isobutylene 1.8% 9.6% % LEL Isopentane 1.4% 7.6% 1000 ppm Isoprene 1.5% 8.9% % LEL Isopropanol 400 ppm 500 ppm 12,000 ppm 2% 12.7% 200, 400, 500, 1000 ppm, % LEL JP4 1.3% 8% 1000 ppm, % LEL JP5 1000, 5000 ppm, % LEL Methane 5% 15% 100, 200, 1000, 1500, 2000, 5000 ppm, 1%, 2% by Volume, 100%, 200% LEL Methanol 200 ppm 250 ppm 25,000 ppm 6% 36% 200, 300, 400, 500, 1000, 2000, 5000 ppm, 15%, 30%, 100% LEL Methyl Acetate 200 ppm 250 ppm 10,000 ppm 3.1% 16% 30 ppm Methyl Acrylate 10 ppm 1000 ppm 2.8% 25% 60 ppm Methyl Bromide 5 ppm 2000 ppm 10% 16% 20, 50, 60, 100, 500, 1000, 10000, 40,000 ppm Methyl Butanol 1.2% 9% % LEL Methyl Cellosolve 2000 ppm % LEL Methyl Chloride 50 ppm 100 ppm 10,000 ppm 8.1% 17.4% 100, 200, 300, 2000, 10000 ppm, % LEL Methyl Ethyl Ketone 200 ppm 300 ppm 1.4% 11.4% 100, 500, 1000, 4000 ppm, 100% LEL Methyl Hydrazine 50 ppm 2.5% 92% 5 ppm Methyl Isobutyl Ketone 50 ppm 75 ppm 200, 500, 2000 ppm, 50%, 100% LEL Methyl Mercaptan 0.5 ppm 400 ppm 3.9% 21.8% 30 ppm Methyl Methacrylate 100 ppm 4000 ppm 1.7% 8.2% 100 ppm, % LEL Methyl-Tert Butyl Ether 40 ppm 100% LEL Methylene Chloride 50 ppm 5000 ppm 13% 23% 20, 100, 200, 300, 400, 500, 600, 1000, 2000, 3000, 5000 ppm, % LEL Mineral Spirits 0.8% 200, 3000 ppm, % LEL Monochlorobenzene 10 ppm 1.3% 9.6% 100% LEL Monoethylamine 5 ppm 15 ppm 4000 ppm 30, 100, 1000 ppm Morpholine 20 ppm 8000 ppm 1.4% 11.2% 500 ppm Naptha 10,000 ppm 1.1% 5.9% 1000 ppm, 100% LEL Natural Gas 1000, 2000 ppm, 2%, 4% by Volume, % LEL Nitric Oxide 25 ppm 100 ppm 20, 50 ppm Nitrogen Dioxide 3 ppm 5 ppm 20, 50, 100 ppm Nitrogen Trifluoride 10 ppm 50, 500, 1000 ppm Nonane 200 ppm 0.8% 2.9% 2000 ppm Oxygen 25% by Volume Pentane 600 ppm 750 ppm 15,000 ppm 1.5% 7.8% 200, 1000 ppm, % LEL Perchloroethylene 25 ppm 100 ppm 500 ppm None 200, 1000, 2000, 20000 ppm Phenol 5 ppm 250 ppm 1.8% 8.6% 100 ppm Phosgene 0.1 ppm 2 ppm 50 ppm Phosphine 0.3 ppm 1 ppm 200 ppm 3, 5, 10, 20, 30, 50 ppm Phosphorus Oxychloride 0.1 ppm 200 ppm Picoline % LEL Propane 20,000 ppm 2.1% 9.5% 100, 1000 ppm, 100% LEL Propylene 2% 11.1% 100, 200, 1000, 5000 ppm, %LEL Propylene Oxide 2000 ppm 2.3% 36% 100 ppm, % LEL Silane 5 ppm 10, 20, 50 ppm Silicon Tetrachloride 1000 ppm Silicon Tetrafluoride 1000 ppm Styrene 50 ppm 100 ppm 5000 ppm 0.9% 6.8% 200, 300 ppm, % LEL Sulfur Dioxide 2 ppm 5 ppm 100 ppm 50, 100 ppm Tetrahydrofuran 200 ppm 250 ppm 20,000 ppm 2% 11.8% 200, 300, 1000 ppm, % LEL Tetraline 0.8% 5% 100 ppm Toluene 50 ppm 2000 ppm 1.1% 7.1% 50, 100, 200, 500, 2000, 5000 ppm, % LEL Toluene Diisocyanate 0.005 ppm 0.02 ppm 10 ppm 0.9% 9.5% 15 ppm Trichloroethane 10 ppm 500 ppm 7.5% 12.5% 50, 100, 500, 1000 ppm, 1% by Volume Trichloroethylene 50 ppm 100 ppm 1000 ppm 8% 10.5% 50, 100,200,300, 500, 1000, 2000 ppm, %LEL Triethylamine (TEA) 1 ppm 5 ppm 1000 ppm 1.2% 8% 100 ppm Trifluoroethanol 25, 100 ppm Trimethylamine (TMA) 5 ppm 15 ppm 2% 11.6% 50 ppm Tungsten Hexafluoride 50 ppm Turpentine 100 ppm 1500 ppm 0.8% % LEL Vinyl Acetate 10 ppm 15 ppm 2.6% 13.4% 1000 ppm, % LEL Vinyl Chloride 5 ppm 3.6% 33 % 20, 50, 100, 200, 400, 500, 1000, 4000, 10000 ppm, 10%, 100% LEL Vinylidene Chloride 5 ppm 20 ppm 6.5% 15.5% 50 ppm Xylene 100 ppm 150 ppm 1000 ppm 0.9% 6.7% 100, 200, 300, 1000 ppm, 1% by Volume 8

9. PRODUCT GUIDE In addition to the three sensor types available for gas detection, there are also a wide variety of instruments to choose from. International Sensor Technology (IST) offers a complete line of instrumentation to meet your needs. The instruments available fall into two basic categories, stationary and portable. 9.1 STATIONARY INSTRUMENTS 9.1.1 Transmitters SM95 The SM95 is a standard sensor transmitter housed in an explosion proof casing. It operates on 14-24 VDC and provides a 4-20 ma output relating to gas concentration. Calibration is performed via adjustments located inside the housing. 4-20 IQ The 4-20 IQ is an intelligent sensor transmitter housed in an explosion proof casing. It operates on 14-24 VDC and provides a linear 4-20 ma output as well as a digital display of gas concentration. This microprocessor based unit also features automated calibration and a magnetically operated front panel so that calibration can be performed without removing the front cover, allowing the unit to be calibrated without declassifying hazardous areas. 9.1.2 Conventional Systems MP SERIES IST s MP Series consists of both rack mounted and weatherproof wall mounted microprocessor based controllers. Because of its slim design, up to 24 channels can be installed in a standard 19 rack space. Or, from 1 to 4 channels can be housed in a weatherproof enclosure. The MP Series controller can accept any sensor module which provides a 4-20 ma or 1-5 VDC output, including IST s intelligent 4-20IQ sensor module (see above). A digital display of gas concentration is provided for each channel and relays are provided for activation of alarm devices. Alarm and fault LED s are also provided for each channel. The MP Series also provides non-intrusive, automated calibration, even for non-intelligent transmitters. 9.1.3 Computerized Systems REMOTE-LINK SYSTEM IST s Remote-Link System is a computerized system which allows sensors to communicate over AC power lines, eliminating the need for individual sensor wiring and producing a significant savings on installation costs. This system is ideal for applications requiring 20 or more sensors. It s modular design allows sensors to be added or removed with ease. The Remote-Link System also comes with the most sophisticated gas monitoring software package available today, with features such as data archiving, curve plotting, TWA calculations, automated calibration, alarm processing, plant graphics display, foreign language support, and much more. 9.2 PORTABLE INSTRUMENTS 9.2.1 Single Gas IQ250/IQ350 4-20 IQ The IQ250 and IQ350 are single gas portables available to detect any one of the over 150 toxic and combustible gases listed in this guide. Both units provide a digital display of gas concentration and an audible alarm, as well as 3 alarm LED s. The IQ250 samples by diffusion, while the IQ350 includes a built-in sampling pump. 9

9.2.2 Multi-Gas IQ1000 The IQ1000 gives you the ability to detect over 100 toxic and combustible gases using a single instrument. It accepts solid state, catalytic bead, and electrochemical sensors and can accommodate up to four sensors at a time. Thus, it is an instrument which can be configured to meet a wide range of applications. The IQ1000 can also be equipped with IST s Mega-Gas Sensor, a solid state sensor capable of detecting over 100 gases. This ability makes the unit ideal for determining IQ200 user confidence concerning the reliability of the instrument and its readings. With the IQ200, however, both sensors are long life sensors. The electrochemical sensor has a five year life expectancy and the solid state sensor has an indefinite life. This results in a unit with low maintenance requirements, low sensor replacement costs, and a high degree of reliability. IQ1000 whether an area contains any hazardous gases at all. The unit samples either by diffusion or via the built-in sample pump. Datalogging is available as an option. IQ200 The IQ200 is a confined space entry portable which detects % LEL combustibles, CO, H2S, and oxygen deficiency. LED s are provided to indicate whether gas levels are safe or not, and an audible buzzer is provided for alarms. Unlike other confined space units, four gases are detected using just two sensors instead of the usual four, making the unit very affordable. A long life electrochemical sensor is used for oxygen, and a solid state sensor is used for the other gases. Typical confined space units utilize electrochemical sensors which require replacement every year or so. In the long run, this results in high operating costs and a low level of NEW INFRARED SENSORS! DETECT CO2 AND METHANE Many of IST s instruments can now be equipped with state-of-the-art INFRARED sensors to detect either CO2 or Methane. For more information, please contact IST. 10

Notes 11

12

INTERNATIONAL SENSOR TECHNOLOGY The Leader In Gas Detection Since 1972 3 Whatney Irvine, California 92618-2824 Telephone 949-452-9000 FAX: 949-452-9009 TLX: 4722070