Associated Hazard (outcome) Control Measures. Reduction of water supply

Similar documents
AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide

DW Module 8: Distribution Answer Key

AFDXXX(X)AC Series Operators Manual Please read this manual thoroughly before attempting to operate your water maker.

Accu-Tab Systems 2000 P Series by Axiall Corporation

Accu-Tab Systems 1000 Series by Axiall Corporation

PRAHER PLC-MP AQUASTAR MANAUL 2009

Swimming Pool Plans and Specification Report

INSTALLATION OPERATION MAINTENANCE

Easy Nest Kits. Installation Suggestions

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

Farm Chlor Chlorinator Instruction Manual

Technical Service Bulletin March 2015 TSB142.01

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

List of Forms. Form Description Page No. Form Commercial Swimming Pool Discharge Application Form 31-4

Waste Management System.

AQUAMATIC EASY NEST KITS INSTALLATION SUGGESTIONS

Simplified Start-Up Checklist For Fully-Pressurized Seasonal Systems

STANDARD OPERATING PROCEDURE

O&M Receiving and Inspection. Storage of Water Treatment Media

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE

SECTION 25 TESTING AND DISINFECTING WATER MAINS General

Commandant United States Coast Guard

Gas Injection Systems

III. Identify the initial installation requirements for standpipe systems

Latvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

Nothing's as cool, as a freshwater pool. easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump

1020 Industrial Drive, Orlinda, TN fax

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

TECHNICAL DATA. Q = C v P S

Swimming Pool IAQUALINK WEB CONNECT

OWNER S TECHNICAL MANUAL

TECHNICAL DATA. Q = C v P S

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:

Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems

OPERATION AND MAINTENANCE

Digester Processes. 1. Raw Sludge Pumping System

SKAC25 Operate plant to maintain the quality of pool water

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

Consult with manufacturers concerning permeation of the pipe walls, jointing materials, valve seats, etc.

The ultimate in water softening

Seattle s Experience with Water Main Depressurization Events

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

BOSS PULISCI PROVA IMPIANTI MEDIA

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

Reverse Osmosis System Installation Guide and Operation Manual.

TECHNICAL DATA. System water supply pressure enters the priming chamber of the deluge valve (A.1) through the 1/4 (8 mm) priming line, which

Water Hygiene Chlorination Water Treatment Legionella Control

Water Facility Maintenance. Using Diving Operations

Contents. Foreword. Acknowledgements. General Introduction

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

TYPICAL TOXIC GAS SYSTEM INSPECTION VIOLATIONS

CORROSION AT THE AIR-WATER INTERFACE REMOVE THE GAS

Saskatchewan Health S A WHIRLPOOL DESIGN/OPERATIONAL T C H E W STANDARDS. Updated 02/00

TECHNICAL DATA. Q = C v P S

VERSION 1 SUMP PUMP PIT UNIT KAWAMOTO PUMP ASIA CO.,LTD.

Additions, Revisions, or Updates

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

OPERATION AND MAINTENANCE MANUAL

TECHNICAL DATA. Dry 132a. October 1, 2008

PUBLIC SPA CHECKLIST. Planning and Building Department City of Mississauga 300 City Centre Drive, 3th Floor Mississauga ON L5B 3C1

TECHNICAL DATA. Q= Cv S

Installation, Operation and Maintenance Manual

CAPITAL CONTROLS SERIES NXT3000

TECHNICAL DATA OBSOLETE

Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection

HIGH PERFORMANCE POOL & SPA PUMPS

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

Additions, Revisions, or Updates

UsER manual for Watersens ph -REDOX

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

Highest Quality. Gas Chlorination Systems

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

The Refurbishment of Filtration & Chemicalisation Systems On A Recent Project

DF1 and DF2 Diffusers

Vehicle-mounted meters, pump supplied

Technical Service Bulletin July 2014 TSB

Western Sydney University Safety Inspection Checklist - Laboratory Environments

Chapter 10 SWIMMING POOLS

Water Facility Maintenance. Using Diving Operations

BIOSAFETY SELF AUDIT PRINCIPAL INVESTIGATOR/PERMIT HOLDER: CONTAINMENT LEVEL: 1 2 (Shaded) RISK GROUP: 1 2 AUDIT TO BE COMPLETED BY (DATE):

Accu-Tab PowerBase 3070AT by Axiall Corporation

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

Dri-Line Mk3 Monnier Compressed Air Drain Trap

hth EASIFLO SYSTEM New Generation for 2015 Feeder specifications hth EASIFLO The perfect solution for treatment of commercial swimming pools

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

Water Fluoridation Operations. Operations is where the operator is successful or not.

2008 by Controlmatik ABW

Chlorinator. MODEL C-731 (Floor Mounted)

Portable Dosing Unit

POOL BACKWASH SYSTEM. Installation manual. Proudly manufactured by

Module No. # 01 Lecture No. # 6.2 HAZOP (continued)

Emergency Response Planning Guide

Figure 2-1 City Of Boynton Beach, Florida Anionic Exchange Resin Facility and East Water Treatment Plant Improvements EXISTING SITE PLAN

Pool and Spa. Water Testing

Public. Water Supply Emergency Response Plan For The. Village of Clayton Water Treatment Facility. Public Water System I.D. No.

Transcription:

Raw water Intake Low lift pumphouse Structural failure of intake Source water Inability to pump-all 4 pumps (loss of power, etc.), structural failure, fire Loss of the 2 larger capacity pumps Structural failure of discharge line Vandalism Reduction of water Water Loss of Loss of (partial or total) Contamination, Loss of (partial or total) Monitoring of intake flows, inspections Monitoring activities in the vicinity of (public, media, emergency services, operators), Raw water monitoring (turbidity, colour, micro-organisms, etc.), operator), regular operator), operator), 1 5 5 / 1 5 5 / 1 2 2 / 3 3 9 No Page 1 of 6

operator), Main Building Lower Chemical Room Coagulant system failure (poly-aluminum chloride) failure of equipment (piping, valves, etc.) Flow meter failure, Flooding,, loss of, loss of control Improper dosing of chemical (PAC) Alarms, inspections,, regular redundancy Daily monitoring, floor drains, overflows,, regular Monitor, calibration, 2 2 4 / Rapid Mix Tanks Flocculation Tanks Filters coagulant feed (flash mixer) (valves) Filter break through (piping, valves, turbidimeters, flow meters, backwash, Short circuiting, insufficient, loss of monitoring security, regular 1 2 2 / 1 2 2 / 2 4 8 Yes Page 2 of 6

pumps) & control, Clearwell Fluoridation Corrosion Control (lime addition) Operational Errors (back wash, loss of media) Flow meter failures (valves) Structural failure (cracks, leakage, ) (dosage pump, ) (dosage pump, ) insufficient, insufficient Improper dosing of chemical (fluoride, chlorine), insufficient, insufficient Over dose of fluoride Lime overdose, insufficient disinfection Lime under-dose, insufficient chlorine residual training, Monitor, calibration, inspection, day tank (limits the amount of fluoride that can be delivered without Operator control), anti-siphoning valve 3 1 3 / 2 2 4 / 2 3 6 Yes 1 1 1 / 3 1 3 / Page 3 of 6

Disinfection High lift Standpipes Transmission main (loss of chlorinator) underdosing Chlorine leak (major) Inability to pump (valves, pipe, electricals) (insufficient disinfection) Causing additional equipment failure, safety concern, Loss of, reduced alarms (gas detection), Loss of all pumps Loss of Loss of #2,#3 & #4 at the same time Loss of any one of or two of #2,#3 & #4 at the same time (valves, piping, structure) Vandalism Flooding of valve chamber Structural failure (major main break) Partial loss of Partial loss of Loss of storage or Restricted access to valve chamber Loss of or, Inspection, restricted access 1 4 4 Yes Mandatory CCP 1 4 4 2 4 8 No Valve/header failure could lead to plant shut-down until repaired EMERGENCY 1 5 5 / EMERGENCY 1 1 1 / Inspection 1 1 1 /, public notification 2 4 8 No EMERGENCY Page 4 of 6

Distribution mains Vandalism/terrorism Accident/act of god/(earthquake, forest fire, storm, vermin, pestilence), civil insurrections Structural failure (major main break),, low pressure, public notification Cross connection By-law, monitoring, regular Low chlorine residual High chlorine residual Valve failure Flushing/swabbing blockages Structural failure, Structural failure, Possible Potential to exceed standard requirements,, low pressure Low chlorine residuals,, Loss of, of Loss of, of Daily monitoring, regular distribution sampling, flushing Consumer complaints, daily monitoring, regular distribution sampling, flushing public notification 4 2 8 No 3 3 9 Yes.2 mg/l control limit, reportable 0.05 mg/l 3 2 6 No Training restricted access Management EMERGENCY 2 4 8 No EMERGENCY Page 5 of 6

Complete failure Loss of Power including back-up power (includes failure of transfer switch) Loss of Utility Power Analyzer failure(s) Major Fire at WTP (impacting MCC panels, chlorine cylinders, diesel room) Waste water disposal system Labour disruptions Y-Strainer Obstruction Loss of auto-dialer Less convenient monitoring and control Contamination, loss of Contamination, loss of Potential Loss of, Failure of waste water disposal system Loss of, Loss of critical process water No notification to adverse conditions Operational issue (additional staffing) Compliance issues Loss of, Partial Loss of Supply, Contamination Potential Loss, No drinking water health hazard Loss, Loss of chemical feed systems Potential compliance or issues Spare parts, available tech support, regular Management Spare parts, available tech support, regular Management Supernatant back to the lake Management, strike plan Monitoring and scheduled routine Routine scheduled testing of system 1 5 5 / EMERGENCY 3 2 6 No 1 5 5 No EMERGENCY 1 1 1 No 1 3 3 No EMERGENCY 2 2 4 No 3 2 6 No Page 6 of 6