Nataliya Sharova, Truls Norby NorECs Norwegian Electro Ceramics AS

Similar documents
DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

ACV-10 Automatic Control Valve

Gas density monitor With integrated transmitter Model GDM-100-TI

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Zirconia Oxygen Sensors. Model 1230 Series

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

High-performance submersible pressure transmitter For level measurement Model LH-10

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Zirconia Oxygen Analyzer Systems

High-performance submersible pressure transmitter For level measurement Model LH-10

Technical Data Sheet MF010-O-LC

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

Hand-held pressure calibrator with integrated pump Model CPH6600

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

PERME- OX2/230 Oxygen Transmission Rate test system

MCQ Gas Blender 100 Series 3 Channels Gas Mixer

Additel 780 Series Pressure Controller

FLOWMETER UNITS FLOWMETER DEVICES, BY-PASS SYSTEMS

Long term stability tests of INO RPC prototypes

Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

Overview. Front Panel: Keypad and Display

AMS 2710 PCB pressure sensor module with V output

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

All Molybdenum Hot Zone & Elements. All Insulators are made of High Alumina. Element style - 1/8 Molybdenum Wire.

Granville-Phillips Series 370 Stabil-Ion Vacuum Gauge Controller

Columbus Instruments

Expert Hydrostatic Level Transmitters

High-performance submersible pressure transmitter For level measurement Model LH-20

OMNISTAR / THERMOSTAR. The efficient solution for gas analysis. Intelligent software. Wide range of applications.

InFlow Modular perfusion bioreactor

JETFIRST 150 RTA SYSTEM OPERATING MANUAL Version: 2 Feb 2012

The Broadest Gauging Line in the Industry

Mass Flowmeters. Mass Flowmeters for Gases

Autocalibration Systems For In Situ Oxygen Analyzers

Additel 780 Series Pressure Controller

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

Mass Flow Controller (MFC) for Gases

Description Advanced Features Typical Applications

AMS 6916 Board mount pressure sensor with ratiometric analog output

Oxymax H COS21. Technical Information. Sensor with long-term stability for frequent sterilization and autoclaving

Pressure Transmitters 36 F-27839

ZIRCONIA OXYGEN DETECTOR SERVICE MANUAL

Over 20,000 Strain Gage Target flowmeters installed since 1952.

High-performance submersible pressure transmitter For level measurement Model LH-20

PURA. Pure Gas Dewpoint Transmitter. Users Guide

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

User s Guide. Vacuum Controller for liquid delivery systems

SonoMeter 30 Energy Meters

BSP Pressure Sensor Balluff GmbH, BA Marco Zorcic.

Laboratory Flowmeters

Autocalibration Systems for In Situ Oxygen Analyzers

[Instruments for vacuum measurement, checking and adjustment] 3

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Teacher s Assistant Laboratory Guide

EMISSION CHAMBERS. Bulk and Surface Emission Detection for the RAD7 User Manual

better measurement Simply a question of

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

MINIBRUTE ANNEAL TUBE STANDARD OPERATION PROCEDURE

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

High-performance submersible pressure transmitter For level measurement Model LH-20

How to calibrate the formaldehyde sensor within a PPMonitor Wireless Unit:

Vacuum. Dry Turbo Pumping Stations. Roughing Pumps for 1 K Helium Pots and Lambda Refrigerators. Hermetically Sealed Pumps for He3 Recirculation

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

User Manual. Quantos Automated Dosing Liquid Module

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

Hidrostatic Level DATASHEET

APPLICATION NOTES DELOMATIC 4, DM-4 GAS

O 2 SENSORS Zirconium Dioxide (ZrO 2 ) Oxygen Sensor Operating Principle Guide

SITRANS P measuring instruments for pressure

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

FTC130 Transmitter. Operating Manual

Precision pressure sensor Basic version Model CPT6020

ETCHING OF COPPER COATED MYLAR TUBES WITH CF4 GAS. Karl M. Ecklund, Keith W. Hartman, Michael J. Hebert, Stanley G. Wojcicki

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

User Manual. ECC-Opto-Gas. Release Electrochemical test cell EL-CELL GmbH

Procedure Instruction of program Pressurized Enclosure - Test Round 2017

BekkTech s Procedures For Performing In Plane Membrane Conductivity Testing

FAS-W. Features. Applications. Automatic condensation hygrometer

Gas Sampling Fitting with MK2.1 and L-Probe

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

JUMO dtrans p30 Pressure Transmitter

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring

MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400

Thermcraft Tube Furnace General Use

The affordable consumption counter for compressed air and gases R 3 /4 (DN 20)

STERILIZABLE DISSOLVED OXYGEN SENSORS

TIGHTNESS. Glass sealing Thanks to our glass-sealing technology, ODU products can meet the most demanding tightness requirements.

HumiSys HF High Flow RH Generator

WP Eliminating Oxygen from the Purge Gas and the use of Monitoring Equipment

Application Note AN-107

Best Practice Guide, Servomex 2700

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

TH-1800-T TRX-700-CNG Converter

Hiden QIC Series Gas Analysers Real-time gas analysis systems

Transcription:

Nataliya Sharova, Truls Norby NorECs Norwegian Electro Ceramics AS International Symposium on Diagnostic Tools for Fuel Cells Technologies June 23-24, 2009, Trondheim, Norway

Who are we? NorECs is a small company that designs and manufactures equipment for high-temperature electrochemical research. Ouraim isto commercialize a broader range of scientific equipment, materials, and applications derived from Norwegian university research. Our focus is electroceramics, their properties, and characterization at high temperatures and under controlled atmospheres.

Fuel cell testing; Stacks and button cells The ProboStat sample holder system Button Fuel Cell test with the ProboStat Feeding Fuel and Oxidant; FCMix Button-cell test using the ProboStat and FCMix Conclusions

Stacks Sealing Current collection Thermal management Water handling Fuel utilisation Cycling thermal, red-ox Interconnect behaviours Contamination; Cr, Si

Button cells Sealing Current collection Fuel and air supply Cycling; thermal, red-ox Contamination (Si ) Water handling (?) Safety (?) Relevance (!) SOFC based on LaGaO 3 ( Mitsubishi Materials Corporation) ProboStat

ProboStat is a versatile sample holder for measurements of electrical properties, transport parameters, and kinetics of materials, solid/gas interfaces and electrodes at high temperature under controlled atmospheres. Samples: up to 24 mm disk up to 50 mm long bar Temperature: long term < 1400 C, short term < 1600 C. Atmospheres: Oxidizing, inert, reducing Wet or dry Single or dual Brief specification Running experiment with the ProboStat. (UiO) Overpressure:ca. 20 atm (with MA253 SS outer tube) at 900 C Vacuum: ca. 1 10-2 mbar Maximum current: 5 A Maximum voltage: 42 V 10 kv (upon request) Overall length: 75 cm Outer tube diameter: 40 mm

One cell; many accessories, methods, properties Material properties and applicable methods: Conductivity vs. T, po 2, ph 2 O, ect. DC, AC, impedance spectroscopy Dielectric properties, loss, ect. Disk, van der Pauw, and bar geometries 2, 3, and 4 electrodes Ionic transport number Proton transport number H/D isotope effect Seebeck coefficient Annealing or sintering under controlled atmospheres I-V characteristics Fuel cell component and single cell testing Electrode kinetics Electrochemical pumping, gas permeation and electrocatalysis with gas analysis (e.g. GC or MC) on outlets Sensor testing Poling of ferroelectrics possible with the high-voltage (10 kv) version

Base unit configuration 16 electrical feedthroughs 6 for electrodes, 4 for shields, 3 2 for thermocouples; 4 gas inlets/outlets (brass or steel); 3 thermocouple sockets; 6 individual BNC connectors; Water cooling or heating; Grounding and shielding switches; Sockets for sample support tube, enclosing tube, gas supply tubes, spring load.

Base unit configuration Electrical feedthroughs and socket for sample support tube Thermocouple sockets gas inlets/outlets for inner and outer chambers BNC connectors Gas inlet and outlet for inner chamber Gas inlet and outlet for outer chamber Water cooling / heating Shields and grounding switches

Extencively furnished system Base unit accessories Support tube assemblies in 5 standard sizes for disk and bar samples; Gas supply tubes; Spring-load assemblies; Thermocouples; Electrode contacts; Grounding; Internal shielding; Sockets for HT tube for sample support, enclosures and gases. Base unit, BNC and thermocouple compensation cables, small parts. Outer tubes and support tube assemblies. Gas supply tubes, electrodes, thermocouples, spring-load system parts.

SOFC test setup Fortunately there are now a number of commercially available test fixtures, such as the ProboStat, that conform to the basic design parameters of the apparatus described above www.fuelcellmaterials.com 1 2 3 4 5 6 Assembling for SOFC test 1. Sample support tube and multi-bore inner gas tube. 2. Inner Pt two wire hand electrode contact with Pt net. 3. Gold sealing ring. 4. ASC2 button fuel cell from InDEC B.V. 5. Outer Pt two wire hand electrode contact with Pt net, thermocouple (S-type). 6. Spring-load system, outer quartz gas tube, and thermocouple protection cap.

FCMix FCMix: simple & safe gas mixer for tests of small fuel cells Supply and wetting of fuel and oxidant with fine control of flow and overpressure. Three digital flowmeters calibrated for e.g. H 2, Ar and air. Routable inert gas allows soft and safe start. Two simple gas humidifiers with overpressure safeguard and regulation. Flow rate, e.g. 50 ml/min. 19 rack mount or benchtop Alternative to expensive and sometimes overdimensioned FC test stations that work with too rough overpressure controls. FCMix ProGasMix is a versatile gas mixer for simultaneous control of (po 2 +ph 2 O) over entire po 2 range from oxidizing to reducing conditions. ProGasMix can blend up to 3 gases in 2 different mixtures + control humidity.

with ProboStat and FCMix U, V 1,2 1,0 0,8 0,6 0,4 P at 800 o C P at 700 o C U at 800 o C U at 700 o C 0,6 0,4 P, W/cm 2 0,0 0,2 0,0 0,5 1,0 1,5 I, A/cm 2 0,2 Fig.1. Fuel cell performance for: wet H2, Pt I ASC2 I Pt, dry air U, V 1,1 1,0 0,9 0,8 0,7 0,6 P, home P, InDEC U, home U, InDEC T=800 o C 0,0 0,2 0,4 I, A/cm 2 0,4 P, W/cm 2 0,2 0,0 Fig.2. Fuel cell performances obtained with the ProboStat and from InDEC. ASC2(from InDEC): anode: porous NiO/8YSZ electrolyte: dense 8YSZ cathode: porous LSCF Fuel:wet H 2 ; Oxidant: dry air; Gas flow rate 30 ml/min. Solartron 1287 CorrWare + CorrView Sealing: Gold gasket OCV theor = 1.102 V OCV exp = 1.091 V

The ProboStat is a commercially available sample holder system for the electrochemical characterizations at hightemperatures and under controlled atmospheres. The ProboStat excels in easy exchange of samples and electrodes, and versatility for many tests of materials and electrodes including SOFC research. Fuel and oxidant may be fed with the FCMix a simple gas mixer for the SOFC research. Some elements of future research for diagnostics In-situ spectroscopy & diffraction FCs in the HT ESEM or ETEM