DN 3/8" to 4" Female BSP - 10 C C Max Pressure : 16 Bars up to DN 2 Specifications : Removable stainless steel filter Female / Female

Similar documents
DN 1/2" to 2" Female BSP + 0 C C Max Pressure : 16 Bars Specifications : Stainless steel removable filter Female / Female With draining valve

Materials : Forged carbon steel A105N

Forged stainless steel ASTM A182 F316

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Materials : Stainless steel ASTM A351 CF8M

DN 1/2" to 2 Female - Female BSP - 20 C C Max Pressure : 16 Bars Specifications : Rotating non rising stem Inside screw stem Full bore

Materials : Carbon steel ASTM A216 WCB

DN 1/4" to 3" Female BSP - 10 C C Max Pressure : 25 Bars ( up to DN 1 ) Specifications : Anti blow-out stem With PTFE packing Full bore

Materials : Stainless steel ASTM A351 CF8M

DN 1/2" to 2" Female / Female BSP - 5 C + 60 C Max Pressure : 5 Bars Specifications : Anti blow-out stem Double o ring NBR on stem Full bore

Materials : Forged carbon steel A350 LF2

Materials : Forged carbon steel A105N

Materials : Brass body dezincification-resistant up to DN1 1/4

DN 65 to 100 R.F. PN10 flanges + 5 C + 65 C Max Pressure : 10 Bars Specifications : Brass check valve Controlable With valves DN1/2

Materials : Forged carbon steel A105N

Materials : Brass body dezincification-resistant

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron EN GJL 250 body. Reinforced lug for DN200 :

Ref GAS WAFER BUTTERFLY VALVE. Model/Ref:

Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Materials : Galvanized steel flanges

Materials : Electro galvanized steel flanges

Size : Ends : Min Temperature : Max Temperature : Materials : Galvanized steel flanges

Materials : Dichromate zinc plated steel flanges or AISI 316

Materials : Dichromate zinc plated steel flanges

STAINLESS STEEL LOW PRESSURE REDUCING VALVE LPRV ELITE

STAINLESS STEEL OVERFLOW VALVE TYPE 417

BTV. Internally threaded 2-way control valve. Flow characteristics. Function

CONNECTION > Super-rapid fittings Series 6000 GENERAL DATA. Fitting with connecting tube. Sprint

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

GUMMIKOMPENSATOR GKF8000 / GKF8130

GUKO FDA. einfach. gut. beraten.

Y-Pattern Strainer Valves Range

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions

High Performance BSP Dial Up Pattern Pressure Reducing Valve

WHEATLEY Series 822/820 Swing Check Valve

Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection

Installation, commissioning and servicing instructions

MZX. Three-Port Seat Valves SPECIFICIATIONS AND GUIDE TO SELECTION

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

C 10 Pressure Reducing Valve

Serie 06-M6. Swing wafer check valve. made in. Application fields. Check valves E U R O P E WATER CONDITIONING INDUSTRY

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL PRV44

AVP-F. p setting range (bar) Code No. 003H6200

Pilot Operated Pressure Reducing Valve

FIREFIGHTING EQUIPMENT

Flanged pressure reducer/stabilizer VRCD

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order

776 Cryogenic Safety Valve

CALEFFI. Reduced pressure zone backflow preventer. 574 series 01022/18 NA D E C F B D E. Function

553 Series.

SCA Series Inverted Bucket Steam Traps

HIGH RATE BASKET STRAINER

Pilot Check Valve: Metal Body Type

Self-operated Pressure Regulators for special applications

Installation, commissioning and servicing instructions

CHECK VALVES APPLICATIONS

DS MB, MBF THREE PORT VALVES

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

Rp [ ] Sv min. [ ] C215QP-B 15 1/ C215QP-D 15 1/ C220QP-F 20 3/ [ ]

Overview of types. Technical data. Safety notes

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Pressure reducing valves Index

HERZ-Motorised flow controler

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

Function. brass EN CW617N brass EN CW617N brass EN CW614N. brass EN CW614N brass EN CW617N EPDM

KTM 50 (DN ) Installation, maintenance and operating instructions

PRESSURE REDUCING VALVE EUROBRASS 143 FF

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

Two-port valves, male threaded, PN25

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

2-port seat valves PN25 with externally threaded connections

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

CA10S, CA14 and CA14S Air and Gas Traps

BTD52L Thermodynamic Steam Trap Installation and Maintenance Instructions

DS MZ, MZF, MJF THREE-PORT SEAT VALVES

CA16 and CA16S-14 Air and Gas trap Installation and Maintenance Instructions

PRV4 PT Pressure Reducing Valve

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

End Connection. Thread x Thread N/A N/A N/A N/A Flange x Flange N/A

DESIGN AND PRE - INSTALLATION INFORMATION

INSTALLATION, OPERATING & MAINTENANCE MANUAL WATER DRAIN VALVE

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections

Products no longer available

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET

Overview of types. Technical data

CRP Ltd INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SYRINGE SAMPLING SYSTEMS

130400A 1/2 NPT Female A 3/4 NPT Female A 1 NPT Female A 1 1/4 NPT Female A 1 1/2 NPT Female A 2 NPT Female

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

AIR FOAM CHAMBER DATA SHEET

TITAN FLOW CONTROL, INC.

Transcription:

Size : Ends : Min Temperature : Max Temperature : DN 3/8" to 4" Female BSP - 10 C + 120 C Max Pressure : 16 Bars up to DN 2 Specifications : Removable stainless steel filter Female / Female Materials : Bronze body Page 1 sur 7

SPECIFICATIONS : Removable stainless steel filter Female / female type Horizontal or vertical position with descendant fluid (respect the flow direction indicated by the arrow ) For 202 type, Mesh 4/10 mm ( 400 µ ) up to DN 1 and 5/10 mm ( 500 µ ) over For 203 and 210 types, Mesh 3/10 mm ( 300 µ ) With drainer threaded female BSP with butterfly aluminium handle for 210 type USE : Water distribution and watering Min Temperature Ts : - 10 C Max Temperature Ts :+ 120 C Max Pressure Ps : 16 bars up to DN 2, 10 bars over HEAD LOSS GRAPH : PRESSURE Page 2 sur 7

RANGE : Strainer threaded female BSP cylindric from DN 3/8 to DN 4 for Ref. 202 et 203 Strainer with drain threaded female BSP cylindric from DN 1/2 to DN 2 for Ref. 210 MATERIALS : Item Designation Materials 1 Body Bronze 2 Filter SS 304 3 Gasket PTFE ( 60% ) + Bronze ( 40% ) 4 Cap Brass Page 3 sur 7

SIZE TYPES 202 AND 203 ( in mm ) : Filter size : DN 3/8" 1/2" 3/4" 1" 1"1/4 1"1/2 2" 2"1/2 3 4 Ø 12 15 20 25 32 40 50 65 78 98 L 55 59 69 82 99 109 131 151 172 219 Ref. L1 10 11 12 14 17 17 19 21 21 24 H 40 44 50.5 60 73 80 98 114 130 170 202-203 W 22 26 32 38 48 52 66 82 96 124 Ø D 18 20 25 31 37 43 58 65 75 100 H1 30 32 39 46 55 61 76 90 106 140 Weight ( Kg ) 0.18 0.22 0.34 0.475 0.72 0.9 1.58 2.45 3.4 7.06 Page 4 sur 7

SIZE TYPE 210 ( in mm ) : Filter size : DN 1/2" 3/4" 1" 1"1/4 1"1/2 2" DN1 1/4 3/8 3/8 3/8 3/8 3/8 L 59 69 82 117.5 128 150 Ref. L1 11 12 14 17 17 19 L2 8.5 7.5 7.5 11.5 11.5 11.5 H 44 85 94.5 73 80 98 210 A 38 38 38 50 50 50 Ø D 20 25 31 37 43 58 H1 32 39 46 55 61 76 W 26 32 38 48 52 66 W1 20 20 20 20 20 20 Weight ( Kg ) 0.32 0.42 0.54 0.88 1.05 1.68 Page 5 sur 7

STANDARDS : Fabrication according to ISO 9001 : 2008 DIRECTIVE 97/23/CE : Products excluded from directive ( Article 1, 3.2 ) French water agreement A.C.S. N 09 ACC LY 157 English water agreement WRAS Threaded female BSP cylindric according to ISO 228/1 INSTALLATION POSITIONS : Vertical position ( descendand fluid ) Horizontal position ADVICE : Our opinion and our advice are not guaranteed and SFERACO shall not be liable for the consequences of damages. The customer must check the right choice of the products with the real service conditions. Page 6 sur 7

INSTALLATION INSTRUCTIONS GENERAL GUIDELINES : Ensure that the strainers to be used are appropriate for the conditions of the installation (type of fluid,pressure and temperature). Be sure to have enough valves to be able to isolate the sections of piping as well as the appropriate equipment for maintenance and repair. Ensure that the strainers to be installed are of correct strenght to be able to support the capacity of their usage. Installation of all circuits should ensure that their function can be automatically tested on a regular basis (at least two times a year). INSTALLATION INSTRUCTIONS : Before installing the strainers, clean and remove any objects from the pipes (in particular bits of sealing and metal) which could obstruct and block the strainers. Ensure that both connecting pipes either side of the strainer (upstream and downstream) are aligned (if they re not, the strainer may not work correctly). Make sure that the two sections of the pipe (upstream and downstream) match, the strainer unit will not absorb any gaps. Any distortions in the pipes may affect the thightness of the connection, the working of the strainer and can even cause a rupture. To be sure, place the kit in position to ensure the assembling will work. The theoretical lengths given by ISO/R7 for the tapping are typically longer than required, the length of the thread should be limited, and check that the end of the tube does not press right up to the head of the thread. Never use a vice to tighten the fixings of the strainer. If sections of piping do not have their final support in place, they should be temporarily fixed. This is to avoid unnecessary strain on the strainer. Fluids in the strainer must not contain solid objects ( it could damaged the seat ). Page 7 sur 7