GS20-GS21-GS30 Series

Similar documents
50 Hz. GS20-GS21-GS30 Series. FIXED-SPEED PRESSURE BOOSTER SETS WITH HORIZONTAL CENTRIFUGAL ELECTRIC PUMPS FH and SH SERIES. Cod.

GMD20..NL, GMD30..NL* GHV20..NL, GHV30..NL* GHV40..NL, GTKS20..NL* Series

Multiple Pressure Booster Systems With Variable Speed Controller Type BL

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz

On-Off switch. Selectable manual control for commissioning. Remote start input for control via an irrigation controller, or external sensor.

Locator Locator-D-Lux Air-Saver G1 Air-Saver G2

COMPACT Booster Sets Data Book 50Hz

Hydro Dome GRUNDFOS INSTRUCTIONS

APPLICATIONS. Pumping of clean, non-muddy liquids in the housing, agricultural and industrial sectors.

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

50Hz. water solutions. O SerieS DGO DRO

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM

SINGLE VALVE WITH LOW-FLOW BYPASS

CALEFFI. Ball zone valves. series /03 GB

Torque Tube TB300 Digital Transmitters

Page - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 ITEM QUANTITY FOR MODEL 302

TECHNICAL DATA. Q = C v P S

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

Aquavar SOLO 2 Frequently Asked Questions

SIHI LPH-X - Liquid Ring Compressors

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range

KIT. Small Automatic Water Boosters KIT MODELS

SonoMeter 30 Energy Meters

BOSS PULISCI PROVA IMPIANTI MEDIA

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment)

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA. Q= Cv S

Liquid ring vacuum pumps in compact design

High Pressure Breathing Air Compressors

TECHNICAL DATA. Q = C v P S

Seated valves VRB 3, VRG 3

AIR SAVING PRODUCTS ADDING VALUE AIR-SAVER LOCATOR LOCATOR-EV

Pressure transmitters EMP 2

Submersible Electric Pumps for drainage of clean and slightly dirty water DIWA Series

[Instruments for vacuum measurement, checking and adjustment] 3

Level switches Series LD Vibrating fork level switch for liquids and solids

TECHNICAL DATA. Q = C v P S

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

TECHNICAL DATA. Q = C v P S

COMPRESSED AIR SAVING PRODUCTS INDEX. Useful information AIR-SAVER G1 AIR-SAVER G2 LOCATOR. Condensate Management Specialist

TECHNICAL DATA. Q = C v P S

Flamco Airfix D-E. Installation and operating instructions. 1999, Flamco eps

Level switches Series LD Vibrating fork level switch for liquids and solids

Monitoring device NTS 30

4/2 way Pneumatic Solenoid Valve

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange

Liquid ring vacuum pumps in compact design

TECHNICAL DATA. Q = C v P S

Pressure Automated Calibration Equipment

Uniflair LE TDAR-TUAR

AIR-SAVER G1 AIR-SAVER G2 LOCATOR-EV COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS AIR SAVING PRODUCTS

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

(AS AT 31 st MARCH, 2002)

KSB Delta Compact Type Series Booklet

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Pressure independent control valve (PICV) FLOWMATIC

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

AIR-SAVER G1 AIR-SAVER G2 LOCATOR LOCATOR-EV COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS AIR SAVING PRODUCTS

C-Flow Coriolis Mass Flow Meters

1. PARTS INTRODUCTION ELECTRICAL NOTES INSTALLATION 5/6. 5. START UP 6/7. 6. MAINTENANCE 7/8/9. 7. PRESSURE SWITCH ADJUSTMENTS 9/10.

Product Range. High performance and economic high pressure solutions Made in Germany

Instruction Manual Differential Pressure Transmitter

Installation, Operating, Maintenance and Safety Instructions for. Pressurised water systems for boats

Submersible Pumps Product Overview

INDUSTRIAS IBAIONDO, HYDROPNEUMATIC TANKS

Columbus Instruments

DEEP WELL SUBMERSIBLE PUMPS. An ISO 9001 & Company

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM

erc-o 2 -tech Ò innovative gas systems Markwerbener Str Weißenfels Germany

Flamco Flexcon M-P Pump automat

FLOW. State of the Art ELECTRONIC PUMPS CONTROLLERS. * Electronic starters. * Inverters. * Protection devices YOURWATER UNDER CONTROL

The CWE / HWE-R Series: Overview. Frame and cabinet covering

Euroswim Swimming pool pumps. 11/2010 Copyright of DWT GROUP 1

System Pressure Manager Standard & System Pressure Manager Plus

Budget Range Operators Handbook

CCT-7320/ROC-2313 Reverse Osmosis Controller

STAINLESS STEEL GRAND SERIES

Pressure Transmitters 36 F-27839

Liquid ring compressor

PRODUCTS CATALOGUE 2017 / Torino - Strada Settimo 388/15 Tel (+39) /43 Fax (+39)

GM Series Dual-Block Multi-Function Gas Control Valves

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

Glycol Systems. Engineering Manual. 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers

Pilot valves for pilot operated servo valves

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Automatic balancing valves ASV

GENERIC MANUAL - FOR REFERENCE ONLY. ALL BESPOKE UNITS WILL HAVE PROJECT SPECIFIC DETAILS

6-way characterised control valves DN15 and DN 20

The Discussion of this exercise covers the following points: Pumps Basic operation of a liquid pump Types of liquid pumps The centrifugal pump.

Autocalibration Systems For In Situ Oxygen Analyzers

Expansion Vessels for Potable Installations

Solenoid valves VZWF, force pilot operated

High-performance submersible pressure transmitter For level measurement Model LH-10

OPTIBAR P 1010 C Technical Datasheet

Measuring range Δp (span = 100%) Pa

TotalPac X Single interlock Preaction system Electric release

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

SCA Series Inverted Bucket Steam Traps

Transcription:

GS-GS1-GS3 Series Fixed-speed pressure booster sets with Horizontal Centrifugal electric pumps FH and SH series Hz

WEB 1-1

CONTENTS General introduction... Choice and selection... 13 GS.../FH Series...13 Range... 1 Characteristics of the electric pumps...1 1 Hydraulic performance tables...1 Electric data tables... GSD - GSY Series... 31 GSD1 - GSY1 Series...31 39 GSD3 - GSY3 Series...39 Operating characteristics at Hz... 9 Hc pressure drop curve...9 3

CONTENTS 3 GS.../SH Series...3 Range... Characteristics of the electric pumps... 71 Hydraulic performance tables...71 7 Electric data tables...7 7 GSD - GSY Series...7 81 GSD1 - GSY1 Series...81 89 GSD3 - GSY3 Series...89 9 Operating characteristics at Hz...9 11 Hc pressure drop curve...11 113 Accessories...113 117 Technical Appendix...117

BOOSTER SETS GS SERIES GENERAL INTRODUCTION - PRODUCT DESCRIPTION The GS series pressure booster units mainly comprise pumping stations assembled with two or three SV series vertical multistage pumps, or with FH or SH series enbloc horizontal pumps. A smaller pump can also be added to the main ones. Generally known as a jockey pump, it provides for minor usages in order to maintain system pressure without starting the service pump. The GS series pressure booster units are constant speed sets and are used to distribute water in heating or filling systems. The pumps are mounted on a single base together with the other hydraulic components, such as on-off valves, check valves and the delivery and return manifolds. The electrical panel, supplied with a mounting bracket, is attached to the pressure booster unit base. The pumps start and stop according to the signals sent by the pressure transducer to the electrical control panel. The latter is fitted with an integrated electronic board. The pumps start and stop automatically depending on the water demand of the system. These pressure booster systems are combined with suitable expansion tanks in order to guarantee stable operation and reduce the starting frequency of the pumps. For the correct choice in capacity of the expansion vessel, see the relative chapter on page 1 of the catalogue. DESCRIPTION OF OPERATION The pumps start and stop according to the set pressures detected by the pressure transducer, thus ensuring the required amount of water is delivered. The pressure values can be directly set on the electronic board. For units with jockey pump, the latter will start first and stop last, depending on the set pressure values. When a tap is opened, water is drawn off from the tank, the pressure starts to fall until it reaches the starting value of the first pump. The delivery of water increases, the pressure falls even further and the other pumps start in sequence according to the demand for water. When consumption falls, the pressure in the system increases and the pumps stop when the set threshold pressure values are reached. If consumption falls to zero user demand, the last pump also stops. If the timer function is used, the last pump to work will remain operating for a set time after it is switched off, in order to reach maximum pressure. Make sure the maximum pressure is compatible with the system in which the pump is installed. Example: GS series pressure booster units, operation. H Stop P1 P P3 Pump 1 Pump Pump 3 P1 Start P P3 p Q p pressure differential between pumps, can be reduced to, bar.

BOOSTER SETS GS SERIES CHOICE AND SELECTION The demand of a water distribution system is generally determined by the designer according to the type of user structure being served. Users can be schools, hospitals, homes, offices, industries, hotels, shopping centres and for each the water demand changes due to the different requirements of the people living and working in these structures. To find the correct flow rate for the system in question, it is possible to consult pre-calculated tables that give an idea of the flow rate for the typology of user to serve (see pages 118-119 in this catalogue). Integral system calculation, instead, prevents excessive oversizing and therefore reduces running and installation costs. The theoretical water demand is calculated by summing the demand of each user. As, however, it is improbable that all users will want to use water at the same time, real demand is lower than theoretical demand. After defining the flow rate of the system, the head must be calculated. This must consider the following: - geodesic head: difference in level between the pumping station and the highest user - residual head: pressure demand from the most unfavourable user to serve - pressure drops: value in metres of pressure drops due to friction in the delivery pipes - inlet height: difference in level between the pump inlet and the surface of the water in the tank (positive or negative depending on the installation type) - inlet pressure drops: value in metres of pressure drops due to friction in the inlet piping and in any curves and valves. After analysing the above, the head required for the system is calculated. Now that the flow rate and head values are known, the most suitable pressure booster unit for the system can be chosen. The designer must decide whether to choose a pressure booster unit with two or three pumps, the third being a reserve pump satisfying demand during pump maintenance periods. INSTALLA ALLATION The GS series of pressure booster units must be installed in areas protected from frost and adequately ventilated in order to allow the motors to cool. The delivery and intake pipes should be connected using anti-vibration joints in order to limit vibrations and resonance in the system. Anti-vibration joint delivery suction

BOOSTER SETS GS SERIES INSTALLA ALLATION The GS series of pressure booster units are generally connected to pressurised tanks with a suitable capacity for the system. These tanks are normally expansion vessels for capacities up to L. Tanks with higher capacities can also be supplied if necessary. In these cases, they are air-cushion tanks and a compressor is required to maintain the pressure inside the tank. In both cases, the tanks must be connected on the pressure booster unit delivery line. The system, commonly known as an autoclave, provides the system with a reserve of pressurised water and prevents frequent pump start-ups. For these systems, sufficient space must always be allowed in the area where the pressure booster set is installed. Always check maximum pump pressure in order to choose the right tanks for the pressure in question. SUCTION CONDITIONS Installation of the pressure booster set must be assessed especially as regards intake conditions. Intake conditions can negatively or positively affect the performance of the pressure booster unit and consequently system performance. A positive suction head is ideal for a pressure booster unit as it keeps the pumps constantly primed and the positive difference in level adds pressure to the system. A negative suction head is different. In this case, the risks for the pumps are priming which is connected with the intake piping, the NPSH of the pump and the difference in level between the pump and the water in the tank. In this type of installation, after checking the intake capacity of the pump, the overall pressure drop in the intake line must be calculated as this will reduce pump performance and consequently that of the pressure booster unit. In order to select the right pressure booster unit, the performance levels of the pumps installed on them are indicated in this catalogue. To simplify the calculation of net pressure, pressure drop curves, both for the delivery and intake lines of the pumps have been included (see the relative chapter). 7

BOOSTER SETS GS SERIES CALCULATING NET PRESSURE SURE When selecting the GS series of pressure booster units, reference must be made to pump performance. Performance is calculated from the characteristic curves of the pumps and does not consider any pressure drops generated by pipes and valves as in the pressure booster units. To help choose the right pressure booster unit and calculate the correct pressure at the delivery manifold, the following example is shown: Given the duty point Q = m 3 /h H = 3 mca and with two pumps working, the pump with the most suitable characteristic curve is chosen, that is, the one with a curve that guarantees the required flow and head values. FH -/ ~ 9 [rpm] ISO 99 - Annex A 1 3 Q [Imp gpm] 1 3 Q [US 7 gpm] H [m] H [ft] 1 1 1 18 From the example, we have chosen the FH-/ series pump which guarantees system performance. The pump curve is slightly oversized, but this provides a safety margin to counter the pressure drops in the pressure booster unit pipes. To know the effective pressure at the delivery manifold outlet, the pressure drops in the suction and delivery lines of each pump are calculated. 3 1 P P 3 P 1 8 To simplify calculations, the pressure drop curves for each pump, on page 131 of this catalogue, are used. NPSH [m] 8 NPSH [ft] Assuming a pressure booster unit with check valves on the suction line (curve B of Hc pressure drops) has been selected, one proceeds as follows: 1 8 1 1 1 Q [m 3 1 /h] 1 Q [l/min] 713_A_CH The Hc pressure drops on the pump suction line are to evaluated on the B curve. At a flow rate of 3 m 3 /h the value of Hc = 1, m. Similarly, the Hc pressure drops on the delivery line of the pump, as evaluated on the B curve, are analysed. At a flow rate of 3 m 3 /h, the value of Hc is, m. The total pressure drop on the delivery and suction lines is therefore 1, m. As regards the pressure drop in the suction and delivery manifolds, % with respect to the pressure drops in the pump suction and delivery can be considered. In this case, therefore, the value is,1 m. The total pressure drop is approximately: 1,81 m. Analysing the performance of the unit at a flow rate of m 3 /h, the head H is 38 m. The net pressure at the delivery manifold is 38 1,81 = 3,7 m. Comparing this value with the rated value, 3,7m > 3m. The unit can therefore satisfy the demand of the system. 8

BOOSTER SETS GS SERIES SUCTION CONDITIONS The above example does not consider the suction conditions of the pressure booster unit which, similarly, affect final performance. It is therefore always best to check the suction line for leaks, especially as regards positive head installations. An example of positive head installation relative to the above case is shown below: In the positive head installation, the designer must calculate the minimum installation height Hg of the pump in safety conditions in order to avoid cavitation and, therefore, de-priming of the pump. The relationship that must be checked and which connects this measurement is the following: NPSH available NPSH requested where equality is the limit condition. NPSH available = Patm + Hg - pressure drops. Hg Where: Patm is the atmospheric pressure, equal to 1,33 m Hg is the geodetic difference in level The pressure drops are connected with to the suction piping and relative valves (foot and cut-off valves) NPSH requested is a pump parameter taken from the performance curve of the pump which in our case, at a flow rate of 3 m 3 /h corresponds to, m. Before calculating the NPSH available, the suction pressure drops are calculated using the tables on pages 199- in this catalogue, considering a material such as steel. The chosen diameter of the suction piping is DN1. 9 curve DN1 =,9 m Damper DN1 =, m Drain valve DN1 =,39 m (calculated from supplier data) Piping DN1 =,7 m (assuming a length of, m) Piping DN1, intake manifold =,1 m (length of manifold,89 m) Pressure drops on pump suction side (curve B) = 1,m pressure drops =,8 m Remembering that: NPSH available = 1,33 + Hg -,8 Replacing: 1,33 + Hg -,8, Hg =, +,8 1,33 = -,3 m representing the limit, for which reason: NPSH available = NPSH requested Generally speaking, therefore, in order to assure correct operating conditions as regards the risk of cavitation, the pump must be positioned above the level of the tank so that the suction height is lower than the limit value of,3 m. 9

SET IDENTIFICATION TION CODE GS D I 1 RA / FHE-/11 + CA1/ / DW / PA Options Versions: _ = Standard version DW = Drinking water version A31 = Special version AISI 31 A3 = Special version AISI 3 Code of jockey pump (if present) Code of service pump _ = with check valve on delivery side RA = with check valve on intake side = service pumps 1 = service pumps + 1 jockey pump 3 = 3 service pumps _ = standard I = with self-test Electric starting of service pump D = direct, up to and including kw Y = star/delta SF = Softstarter Reference to series GS = command from a pressure sensor OPTIONS (ON DEMAND) C Unit with two air-cooled compressors EV N electrovalves Volt BAP High pressure switch installed on the delivery manifold CM Oversized suction or delivery manifold CV Unit with expansion vessels (normally litres supplied separately and not mounted) IP Control panel versions IP KV Voltmeter Kit with phase switch MA Pressure gauge installed on suction manifold PA Minimum pressure gauge installed on the suction manifold for dry-running protection PR.C Unit for two air-cooled compressors RA Check valves installed on suction side RE Panel incorporating a thermostat-controlled anti-condensate heater RV Electrical panel with missing-phase, phase-asymmetry, minimum maximum voltage control SA No intake: no suction valves and suction manifold SC Group with no control devices, such as pressure switches and transmitters; the pressure gauge is present SCA No suction manifold (suction valves present) VA Electric control panel fitted with analogue voltmeter and ammeter WM Wall-mounted electrical panel with fixing tabs. Cables L= m PP Pressure-switch control SPECIAL VERSIONS Special versions for materials, operating temperature, control panels with additional functions available on request. 1

CONTROL PANEL FOR GS, GS1, GS3 Electric panel for powering, controlling and protecting a maximum of three three-phase pumps, with sheet steel casing (fig. 1) and protected to IP. fig. 1 Main characteristics: - General doorlock switch, fuse holders and fuses, starting contactors and circuit breakers. - Standard input voltage: 3xVca +/-1%, /Hz. Non-standard voltages available on request, 1x3Vac +/-1%, 3x3ca +/-1%, /Hz. - Transformer for auxiliary low voltage circuit; auxiliary voltage Vac. - SM3 digital microprocessor-controlled control unit with LCD display and programming keyboard (see fig. ), featuring the following functions: Indicator lamps: power on (ref.1), general fault (ref.), no water alarm (ref.3), pump running (ref.); Programming keyboard (ref.); Manual pump stop/start (one button for each pump) (ref.); Automatic cascade pump control with two electronic pressure transmitters. If a sensor develops a fault, the board automatically switches to the second sensor. Pressure switch control available on request. Jockey pump management. Cycle reversal function (can be disabled). Automatically switches pumps after every start/stop cycle. Automatic, manual or disabled mode switches for each pump (inside the board). Periodic system self-test with an electrovalve command which opens the hydraulic circuit, simulates a pressure drop and consequently activates the control devices (pressure switches and pressure transmitters). Pump diagnostics. 1 3 GS fig. No-water protection system alternatives: float, minimum pressure switch, external contact or electrode probes with sensitivity adjustment. Adjustable timer delaying tripping the no-water protection system. Adjustable timer delaying starting of each pump. Adjustable timer extending the operation of each pump. System pressure drop offset function, only available with pressure sensor. This function improves system stability. Adjustable analogue output, -ma or -1Vdc, for visualising the analogue input signal. Configurable relay with volt-free contact, delayed activation, signalling the following conditions: - Motor overload protection alarm. - No-water circuit alarm. - Pressure sensor fault. - Out-of-curve operation alarms (only if self-test is disabled). - Maximum intake pressure alarm. - Electrovalve opening permission for self-test circuit. Configurable digital inputs. - AUX1 input configuration, maximum pressure switch or external self-test. - AUX input configuration, permission from external device (NO) or external alarm (NC). - AUX3 input configuration, change set (NO) or pressure switch operating out-of-curve. 1Vdc output for powering the acoustic alarm. 11

CONTROL PANEL FOR GS, GS1, GS3 Alarms log and hour counters for each installed pump. Alarms visualised on display: - Maximum, minimum pressure; - Circuit breaker for each motor; - Pressure transmitter fault. - Out-of-curve operation; - No water; - Block for tripped external device (PTC, temperature probe, etc.) - Auto-test failed All the alarms light the Fault lamp (ref. fig.) The no-water alarm lights the Level alarm lamp (ref.3 fig.) Standard, RS8 serial communication, slave, and ModBus RTU protocol. The GSM/GPRS module can be connected to send pump alarms and/or operating states via sms or e-mail. Connection via RS8 serial connection. SIM card not included. A relay board (optional) can be connected to boost the following signals: pump running, aut-man mode for each pump, overload alarm, no-water alarm, maximum/minimum pressure alarm, power on, self-test failed. The optional signal booster board has six relays, each of which can be configured using the SM3 control unit. REFERENCE STANDARDS The pressure booster sets are CE-marked for conformity with the following directives: - Machinery Directive: //EC. - Low Voltage Directive /9/EC. - Electromagnetic Compatibility Directive /18/EC. Electric pump performance complies with the following standard: ISO 99-A Rotodynamic pumps hydraulic performance acceptance tests. 1

GS.../FH Series Fixed-speed pressure booster sets Horizontal Centrifugal electric pumps FH series equipped with high efficiency PLM motors flow rate up to 3 m 3 /h Hz GS.../FH 13

GS.../FH SERIES HYDRAULIC PERFORMANCE RANGE AT Hz 3 7 8 1 3 78 1 Q 3 [Imp gpm] 3 7 8 1 3 78 1 3 Q [US gpm] H [m] 1 9 8 7 3 H [ft] GS.../FH 3 1 9 8 7 GS.../FH 1 9 8 7 3 7 8 9 1 3 7 8 91 3 789 Q 1 [m 3 /h] 1 3 8 1 3 8 1 Q [l/min] 739_B_CH 1

RANGE The GS series of fixed-speed pressure boosters comprises models with or 3 electric service pumps and an optional jockey pump in order to satisfy the specific needs of every application. GS SETS Fixed-speed sets with two horizontal service pumps, FH series, with power ratings up to kw. Head up to 1m. Flow rate up to m 3 /h. GS1 SETS Fixed-speed sets with two service pumps and a jockey pump. Horizontal service electric pumps, FH series, with power ratings up to kw. Head up to 1m. Flow rate up to m 3 /h. GS.../FH GS3 SETS Fixed-speed sets with three horizontal service pumps, FH series, with power ratings up to kw. Head up to 1m. Flow rate up to 3 m 3 /h.

CHARACTERISTICS S OF THE ELECTRIC PUMPS The FH series of horizontal centrifugal pumps are single-impeller (FHE, FHS) or twin-impeller (FHE) with cast-iron bodies and AISI 31L stainless steel shafts. Impeller: made of AISI 31L stainless steel laser technology welded, for sizes 3,,, -, or cast iron for sizes -1, -, -, -3, 8, 1,,. Hydraulic sizes and nominal diameter DN of suction and delivery ports according to EN 733 (ex DIN ). Flanges according to EN 19- (ex UNI 3) and DIN 3. Motor: enbloc motor/pump coupling with bracket with impeller directly splined onto the motor shaft protrusion (FHE, FHE) or with joint, adaptor and rigid joint splined onto the shaft protrusion of normalised motors (FHS). Technical data: Flow rate: up to m 3 /h ( poles). 7 m 3 /h ( poles). GS.../FH Head: over 1 m ( poles). m ( poles). Temperature of pumped liquid: from - C to +8 C for FH 3,,,, 8 standard version. from -3 C to +1 C for FH 1,, standard version (including -3, 8-3 and 8-). Up to +1 C for FH 1,, on request. Mechanical seal Mechanical seal according to EN17 (ex DIN 9). Mechanical seal lubricated from circulation duct between the delivery line and the seal for FH 3,,,, 8 (apart from -3, 8-3 and 8-). Seat for mechanical seal peg for FH3,,,, 8 (apart from -3, 8 3 and 8-). Anti-clockwise rotation looking at the pump from the suction port side. Motor Short circuit squirrel cage motor, totally enclosed, fan-cooled. Standard motors up to kw (inclusive) for the -pole version and up to kw (inclusive) for the -pole version. Other motor brands for higher powers. The performance levels of PLM surface motors lie within what is usually referred to as efficiency class 1. Protection class IP. Insulation class F. Performance levels according to EN 3-1. Continuous service. Maximum ambient temperature: + C. Condensate drain plugs on all LOWARA motors. Standard voltage: Single-phase version - Vac, Hz Three-phase version -/38- Vac Hz for power ratings up to 3 kw; 38-/-9 Vac, Hz for power ratings higher than 3 kw. 1

CHARACTERISTICS S OF THE ELECTRIC PUMPS USED IN THE GS SERIES OF PRESSURE SURE BOOSTER SETS HORIZONTAL AL ELECTRIC PUMPS SERIES: FHE 3,,,, 8 FHS, 8 Twin-impeller (FHE) or single-impeller (FHE, FHS) cast iron horizontal centrifugal pump and shaft made of AISI 31L stainless steel. Impeller: made of AISI 31L stainless steel laser technology welded, for sizes 3,, - or cast iron for sizes -1, -, -, 8. Hydraulic sizes and nominal diameter DN of suction and discharge ports according to EN 733 (ex DIN ). Flanges according to EN 19- (ex UNI 3) and DIN 3. Motor: enbloc motor/pump coupling with bracket with impeller directly splined onto the motor shaft protrusion (FHE, FHE) or with joint, adaptor and rigid joint splined onto the shaft protrusion of normalised motors (FHS). The performance levels of PLM surface motors lie within what is usually referred to as efficiency class 1. Performance levels according to EN 3-1. Painting: cathodic epoxy enamel. Booster sets drinking water use (DW version), pump has to have Ceramic, Carbon, EPDM seals. GS.../FH 17

GS.../FH OPERATING CHARACTERISTICS S AND LIMITS Liquids handled Water containing no gas or corrosive and/or aggressive substances. Fluid temperature Above -1 C a + 8 C Ambient temperature Above C a + C Maximum operating pressure 1 bar * Minimum inlet pressure According to NPSH curve and losses, with a minimum margin of. m Maximum inlet pressure The inlet pressure added to the pressure of the pump at zero flow must be lower than the maximum operating pressure of the set. Installation Indoors, protected from the weather. Away from heat sources. Max elevation 1 m ASL. Max humidity % without condensation., kw Pn 3 kw max starts per hour. Direct motor start; kw Pn 7, kw max starts per hour. Direct motor start; Hourly starts (single pump) 11 kw Pn kw max 3 starts per hour. Direct motor start; 18, kw Pn kw max starts per hour. Direct motor start; 3 kw Pn 37 kw max 1 starts per hour. Start/delta start; Pn = kw max 8 starts per hour. Start/delta start; Sound emission See table * On request, PN above in function of the service gfixo_p-en_b_ti If there's jockey pump, PN can be lower SOUND EMISSION SION LEVELS P (kw) IEC* G.. G..3,7 9R <7 <7 1,1 9R <7 <7 1, 9R <7 <7, 9R <7 <7 3 9 <7 7 11R 7 7, 11 71 73 7, 11 7 7 9, 13 7 78 11 13 7 78 1 7 7 18, 1 7 78 18R 73 7 3 83 8 37 83 8 87 89 87 89 * R=Reduced motor casing size with respect to shaft extension and related flange. gsfixo_p-en_a_tr ** Noise value of the electric motor only. Hz 9 rpm LpA (db ±)** 18

MAIN COMPONENTS Main on-off valves fitted to the suction and lines of each pump, ball type with threaded connectors up to series FH, butterfly type for FH and FH 8 pumps. Check valve on the delivery side of each pump, spring type with threaded connected up to ", double-swing type between flanges over ". For applications with air-cushion autoclaves, the check valves are mounted on the suction side and the unit is fitted with a G 1/" threaded hose connector for the air supply (GS RA series). Suction manifold in AISI 3 stainless steel, threaded or flanged depending on the type of pump (see drawings). Threaded water inlet connector. Delivery manifold in AISI 3 stainless steel, threaded or flanged depending on the type of pump (see drawings). Threaded R1" connectors with relative caps for connecting -litre expansion vessels. Pressure gauge and two control transmitters located on the delivery side of the unit. AISI 3 VERSION (GS../A3), AISI 31 (GS../A31) For special uses The manifolds, valves, check valves and the main elements with parts in direct contact with the fluid are made of AISI 3 or AISI 31 stainless steel. Optional accessories: Dry-running prevention devices in one of the following versions: - float switch, for positive heads; - pack of probe electrodes, for positive heads. Autoclaves in the following versions: - Air-cushion autoclaves with compressor and accessories for autoclave and compressor. - Diaphragm autoclaves instead of air-cushion versions. lt diaphragm expansion vessel with ball valve (one for each pump) in the following versions, depending on the maximum head of the pumps: - Hydro tube kit L 8 bar - Hydro tube kit L 1 bar - Hydro tube kit L 1 bar Alarms kit; Air suction for RA version; Air compressor for RA version; GS.../FH Various fittings in nickel-plated brass, galvanised steel or stainless steel depending on the version. Support base for pump unit and board bracket in painted steel. Control panel protected to IP. AVAILABLE AILABLE STANDARD VERSIONS See material table. STANDARD VERSION For or general use Ball valves in nickel-plated brass, butterfly valves in polyamide, check valves in brass or painted cast-iron with flaps in steel, plugs, splines and flanges galvanised steel; manifolds in A3. DW VERSION (GS../DW) For use with drinking water The main components in contact with the fluid are certified for drinking water or made from AISI 3 or superior stainless steel. Valves in nickel-plated brass, butterfly valves in epoxy, check valves with flaps in AISI 3 steel; manifolds in A3. SPECIAL VERSIONS AVAILABLE AILABLE ON REQUEST (Contact the Sales and Technical Assistance Service) Units with non-standard input voltages, such as three-phase 3x3V, 3xV. Units with single-phase input voltages 1x3V. Jockey pump other than the standard ones illustrated in the catalogue. Support base in AISI 3, AISI 31 stainless steel. Units with stainless steel expansion vessels. Units with special valves. Units with electric pumps (GS...). Units with electric pumps (GS1... GS...). 19

TABLE OF MATERIALS FOR SETS WITH FHE 3-- PUMPS NAME MATERIAL (STANDARD) DW A3 A31 Manifolds AISI 3 AISI 3 AISI 3 AISI 31 On-off valves Nickel-plated brass Nickel-plated brass for AISI 3 drinking water AISI 31 Non-return valves AISI 3 AISI 3 AISI 3 AISI 31 Pressure switches Chrome plated zinc alloy AISI 3 AISI 3 AISI 3 Pressure transmitters AISI 31 AISI 31 AISI 31 AISI 31 Nipples/caps/plugs/flanges Galvanized steel AISI 31 AISI 31 AISI 31 Bracket Painted steel Painted steel Painted steel Painted steel Base Painted steel Painted steel Painted steel Painted steel Electric pump body Painted cast-iron for drinking water Painted cast-iron for drinking water Painted cast-iron for drinking water Painted cast-iron for drinking water GS.../FH TABLE OF MATERIALS FOR SETS WITH FHE/FHS -8 PUMPS NAME MATERIAL (STANDARD) DW A3 A31 Manifolds AISI 3 AISI 3 AISI 3 AISI 31 On-off valves Polyamide Polyamide AISI 3 AISI 31 gfixofh_p-en_a_tm Non-return valves Painted cast-iron with stainless steel flaps Painted cast-iron with stainless steel flaps AISI 3 AISI 31 Pressure switches Chrome plated zinc alloy AISI 3 AISI 3 AISI 3 Pressure transmitters AISI 31 AISI 31 AISI 31 AISI 31 Nipples/caps/plugs/flanges Galvanized steel AISI 31 AISI 31 AISI 31 Bracket Painted steel Painted steel Painted steel Painted steel Base Painted steel Painted steel Painted steel Painted steel Electric pump body Painted cast-iron for drinking water Painted cast-iron for drinking water Painted cast-iron for drinking water Painted cast-iron for drinking water gfixofh-8_p-en_a_tm

GS.../FH SERIES BOOSTER SETS HYDRAULIC PERFORMANCE TABLE AT HZ (JOCKEY PUMP) PUMP NOMINAL Q = DELIVERY TYPE POWER l/min 1 3 3 73 m 3 /h,7 1, 1, 1,8,1,,7 3, 3,, kw HP H = TOTAL HEAD METRES COLUMN OF WATER 3SV,37, 1, 1,3 1, 13, 13, 1, 11,7 9,8, 3SV3,37, 1,,8,3 19, 18,7 17,7 1, 13,7 8, 3SV,37, 9 7,7 7,1,, 3,9,,8 1,8 1,1 3SV,,7 37 3, 3,8 3, 33,9 3, 31,1 9,, 1, 3SV,,7 3,, 1,, 38, 3, 3,3 8, 18, 3SV7,,7 3 1,8 1,, 8,7 7,,, 3,1, 3SV8,7 1 9,1 8, 7,, 3, 1, 8,1,7 7, 3SV9 1,1 1, 8,8,8,,8, 7,9,, 31, 3SV1 1,1 1, 7 73,8 7,7 71,3 9,3,9 3,8, 1, 3, 3SV11 1,1 1, 8 81, 79,7 78, 7,8 73,1 9,7,7, 37, 3SV1 1,1 1, 9 87,8 8, 8, 8,1 79,1 7, 71,1 9,9,1 3SV13 1, 98 9,7 9, 93, 91, 87,8 83,9 79, 7,, 3SV1 1, 1 1,1 1, 1, 97,7 9, 89,9 8,8 71,8 8, 3SV1 1, 1 117,8 11,1 113, 11, 1, 11, 9,8 8,9, 3SV19, 3 1 1,3 1,3 137, 133,9 19, 13, 11,7 99,1 7, 3SV1, 3 9 7 1 17 1 13 18 18 7 GS.../FH gfix_fhe_pp_3sv-p-en_a_th POMPA TIPO POTENZA Q = PORTATA NOMINALE l/min 3 7 8 1 1 m 3 /h 1,8, 3 3,,,8 7, 9 kw HP H = PREVALENZA TOTALE IN METRI COLONNA ACQUA CA 7/33,7 1,9 38,8 3,9 3, 31,7 8, 3,9 CA 7/3,9 1, 8,8,1 3,,7 37,7 3, 9, CA 7/ 1,1 1,,, 9,8 7,1 3,9 39,9 3,3 CA 1/, 3 3,8 9, 8,,,8,,7 37,1 Prestazioni conformi alle norme ISO 99 - Annex A. 99_pp_ca-p_a_th 1

GS.../FH GS/FH 3-, GS1/FH 3- SERIES BOOSTER SETS HYDRAULIC PERFORMANCE TABLE AT HZ (SERVICE PUMP) SET NOMINAL Q = DELIVERY TYPE POWER l/min 3 8 9 1 1 1 18 8 3 GS/.. m 3 /h 1 18 3 3 8 7 8 9 18 1 18 18 kw H = TOTAL HEAD METRES COLUMN OF WATER FHE 3-/7 x,7 1,9 1, 11, 8,7 FHE 3-/11 x 1,1 1,9 19, 1,3 1, 9, FHE 3-1/ x 1, 7,3,, 17,8 11, FHE 3-1/ x, 3,7 3, 8,,3 18,8, FHE 3-/3 x 3, 39,8 3, 3,, 19,8 FHE 3-/ x,,, 1,9 3, 3,3 FHE 3-/ x, 79, 7,7 71,,, 37, FHE 3-/7 x 7, 99, 9,3 9, 83, 7, 8, FHE -/11 x 1,1 1, 13, 11,3 1,1,8 FHE -/ x 1, 18,1 1,7, 13,9 9,, FHE -/ x,, 3, 1,,1,8 1,3 8, FHE -1/3 x 3 31, 9, 7,,1 1, 17, FHE -1/ x 38, 3, 3, 33, 8,,,1 FHE -/ x,,, 1,, 3, 9, FHE -/7 x 7, 7,,,,, 1, 3,1 FHE -/9 x 9,, 9,,, 9,, 39, FHE -/11 x 11 7, 7,, 3, 7,, 7, FHE -/ x 8, 8, 77, 7, 7,,, The table refers to performance with pumps running. gfix_fhe3-_p-p-en_b_th GS/FH -8, GS1/FH -8 SERIES BOOSTER SETS HYDRAULIC PERFORMANCE TABLE AT HZ (SERVICE PUMP) SET NOMINAL Q = DELIVERY TYPE POWER l/min 8 9 1 1 1 18 8 3 3 7 GS/.. m 3 /h 8 7 8 9 18 1 18 18 1 7 3 kw H = PREVALENZA TOTALE IN METRI COLONNA ACQUA FHE -/ x, 17,,1 1, 1,8 11,, FHE -/3 x 3, 18,8 18, 1,9, 1, FHE -/ x, 3,1, 1,,3,8 11,8 FHE -1/ x, 3, 3, 9, 8,,, 1,8 FHE -1/7 x 7,, 38, 37, 3, 3, 9,, 1, FHE -/9 x 9,,,8, 3,,9 3,,7 FHE -/11 x 11 8,, 3,, 8,3, 33, 9, FHE -/ x 8,, 3, 1, 9,, 1, FHE -/18 x 18, 77, 73, 7, 7, 8,,, 7, FHE -/ x 8, 8, 81, 8, 78, 7, 1, 7, FHE -/ x 19, 17,3 1,8 1, 13, 11,8 FHE -/ x, 3, 1,3,9 19, 17, 1,7 13,7 FHE -/7 x 7, 7,,,, 3,,, 18, FHE -1/9 x 9, 33, 31, 3, 8, 7,1, 1, FHE -1/11 x 11 3, 3, 33, 31, 3,8 8,, FHE -1/ x, 1,, 38, 37,8 3, 33, 9, FHE -/ x,, 3, 1,, 3, 3, FHE -/18 x 18,,, 1, 9, 8,,, FHE -/ x 9, 9, 8,,,, 9,, FHE -/ x, 1, 8,,, 8,, FHS-/3 x 3 7, 7, 73, 7, 9,, 1,, FHS-/37 x 37 9, 88, 8, 8, 8, 78, 7, 8, FHE8-1/11 x 11 7, 7,3,,, 1, FHE8-1/ x 33, 3, 31, 3, 8,, 1, FHE8-1/18 x 18, 39, 38, 3, 3, 3, 8, 3,3 FHE8-/ x 8, 7,, 3, 1, 3,, FHS8-/3 x 3, 9, 8, 7,, 7,, FHS8-/37 x 37 71, 7, 7,, 1, 9, 38, FHS8-/ x 8, 8, 78, 7, 7,, 1, FHS8-/ x 9, 93, 91, 89, 8, 77, 8, The table refers to performance with pumps running. gms_pfh-8_p-en_a_th

GS3/FH 3- SERIES BOOSTER SETS HYDRAULIC PERFORMANCE TABLE AT HZ (SERVICE PUMP) SET NOMINAL Q = DELIVERY TYPE POWER l/min 3 7 9 1 13 18 1 7 3 GS3/.. m 3 /h 18 7 7 81 18 1 1 1 1 7 kw H = PREVALENZA TOTALE IN METRI COLONNA ACQUA FHE 3-/7 3 x,7 1,9 1, 11, 8,7 FHE 3-/11 3 x 1,1 1,9 19, 1,3 1, 9, FHE 3-1/ 3 x 1, 7,3,, 17,8 11, FHE 3-1/ 3 x, 3,7 3, 8,,3 18,8, FHE 3-/3 3 x 3, 39,8 3, 3,, 19,8 FHE 3-/ 3 x,,, 1,9 3, 3,3 FHE 3-/ 3 x, 79, 7,7 71,,, 37, FHE 3-/7 3 x 7, 99, 9,3 9, 83, 7, 8, FHE -/11 3 x 1,1 1, 13, 11,3 1,1,8 FHE -/ 3 x 1, 18,1 1,7, 13,9 9,, FHE -/ 3 x,, 3, 1,,1,8 1,3 8, FHE -1/3 3 x 3 31, 9, 7,,1 1, 17, FHE -1/ 3 x 38, 3, 3, 33, 8,,,1 FHE -/ 3 x,,, 1,, 3, 9, FHE -/7 3 x 7, 7,,,,, 1, 3,1 FHE -/9 3 x 9,, 9,,, 9,, 39, FHE -/11 3 x 11 7, 7,, 3, 7,, 7, FHE -/ 3 x 8, 8, 77, 7, 7,,, The table refers to performance with 3 pumps running. gfix_fhe3-_3p-p-en_b_th GS3/FH -8 SERIES BOOSTER SETS HYDRAULIC PERFORMANCE TABLE AT HZ (SERVICE PUMP) SET NOMINAL Q = DELIVERY TYPE POWER l/min 1 13 18 1 7 3 9 9 GS3/.. m 3 /h 7 81 18 1 1 1 1 7 3 3 1 3 kw FHE -/ 3 x, 17,,1 1, 1,8 11,, FHE -/3 3 x 3, 18,8 18, 1,9, 1, FHE -/ 3 x, 3,1, 1,,3,8 11,8 FHE -1/ 3 x, 3, 3, 9, 8,,, 1,8 FHE -1/7 3 x 7,, 38, 37, 3, 3, 9,, 1, FHE -/9 3 x 9,,,8, 3,,9 3,,7 FHE -/11 3 x 11 8,, 3,, 8,3, 33, 9, FHE -/ 3 x 8,, 3, 1, 9,, 1, FHE -/18 3 x 18, 77, 73, 7, 7, 8,,, 7, FHE -/ 3 x 8, 8, 81, 8, 78, 7, 1, 7, FHE -/ 3 x 19, 17,3 1,8 1, 13, 11,8 FHE -/ 3 x, 3, 1,3,9 19, 17, 1,7 13,7 FHE -/7 3 x 7, 7,,,, 3,,, 18, FHE -1/9 3 x 9, 33, 31, 3, 8, 7,1, 1, FHE -1/11 3 x 11 3, 3, 33, 31, 3,8 8,, FHE -1/ 3 x, 1,, 38, 37,8 3, 33, 9, FHE -/ 3 x,, 3, 1,, 3, 3, FHE -/18 3 x 18,,, 1, 9, 8,,, FHE -/ 3 x 9, 9, 8,,,, 9,, FHE -/ 3 x, 1, 8,,, 8,, FHS-/3 3 x 3 7, 7, 73, 7, 9,, 1,, FHS-/37 3 x 37 9, 88, 8, 8, 8, 78, 7, 8, FHE8-1/11 3 x 11 7, 7,3,,, 1, FHE8-1/ 3 x 33, 3, 31, 3, 8,, 1, FHE8-1/18 3 x 18, 39, 38, 3, 3, 3, 8, 3,3 FHE8-/ 3 x 8, 7,, 3, 1, 3,, FHS8-/3 3 x 3, 9, 8, 7,, 7,, FHS8-/37 3 x 37 71, 7, 7,, 1, 9, 38, FHS8-/ 3 x 8, 8, 78, 7, 7,, 1, FHS8-/ 3 x 9, 93, 91, 89, 8, 77, 8, The table refers to performance with 3 pumps running. H = PREVALENZA TOTALE IN METRI COLONNA ACQUA gms_3pfh-8_p-en_a_th GS.../FH 3

GS, GS1, GS3/FH SERIES BOOSTER SETS ELECTRICAL DATA A TABLE AT Hz SERVICE JOCKEY PUMP PUMP 3 X V 3 X V CURRENT ABSORBED BY SET 3 X V GS.../FH TYPE Pn In TYPE Pn In GS GS1 GS3 kw A kw A A A A FHE 3-/7,7,1 CA7/33,7,18,3,,8 FHE 3-/11 1,1,1 CA7/33,7,18, 7, 7,83 FHE 3-1/ 1, 3, CA7/33,7,18,9 9,8 1,3 FHE 3-1/,,3 CA7/33,7,18 1, 1,,9 FHE 3-/3 3, CA7/3,9,1 1,,11 18,7 FHE 3-/ 7,71 CA7/ 1,1 3,, 18, 3,13 FHE 3-/, 1, 3SV11 1,1,1,8 3,1 31, FHE 3-/7 7, 13,9 3SV13 1, 3, 7,8 31, 1,7 FHE -/11 1,1,1 CA7/33,7,18, 7, 7,83 FHE -/ 1, 3, CA7/33,7,18,9 9,8 1,3 FHE -/,,3 CA7/33,7,18 1, 1,,9 FHE -1/3 3, CA7/33,7,18 1, 1,8 18,7 FHE -1/ 7,71 CA7/33,7,18, 17, 3,13 FHE -/, 1, CA7/3,9,1,8 3,1 31, FHE -/7 7, 13,9 CA7/ 1,1 3, 7,8 3,8 1,7 FHE -/9 9, 1,7 CA1/ 1,8,13 33, 38,3,1 FHE -/11 11, 3SV1 1,1,1, 3,1, FHE -/, 3SV1 1,1,1,,1 78, FHE -/,,3 CA7/33,7,18 1, 1,,9 FHE -/3 3, CA7/33,7,18 1, 1,8 18,7 FHE -/ 7,71 CA7/33,7,18, 17, 3,13 FHE -1/, 1, CA7/33,7,18,8,98 31, FHE -1/7 7, 13,9 CA7/33,7,18 7,8 9,98 1,7 FHE -/9 9, 1,7 CA7/ 1,1 3, 33, 3,,1 FHE -/11 11, CA1/ 1,8,13,,3, FHE -/, 3SV1 1,1,1,,1 78, FHE -/18 18, 33, 3SV11 1,1,1,8 9,1 1, FHE -/ 37,9 3SV1 1,1,1 7,8 78,1 113,7 FHE -/ 7,71 CA7/33,7,18, 17, 3,13 FHE -/, 1, CA7/33,7,18,8,98 31, FHE -/7 7, 13,9 CA7/33,7,18 7,8 9,98 1,7 FHE -1/9 9, 1,7 CA7/33,7,18 33, 3,8,1 FHE -1/11 11, CA7/33,7,18,,8, FHE -1/, CA7/33,7,18,,8 78, FHE -/, CA7/3,9,1,,1 78, FHE -/18 18, 33, CA7/ 1,1 3,,8 9,8 1, FHE -/ 37,9 CA1/ 1,8,13 7,8 8,93 113,7 FHE -/ 37,9 CA1/ 1,8,13 7,8 8,93 113,7 FHS-/3 3, 3SV11 1,1 3, 18, 111, 1, FHS-/37 37, 3SV13 1, 3, 13, 133, 19, FHE8-1/11 11, CA7/33,7,18,,8, FHE8-1/, CA7/33,7,18,,8 78, FHE8-1/18 18, 33, CA7/33,7,18,8 8,98 1, FHE8-/ 37,9 CA7/3,9,1 7,8 77,9 113,7 FHS8-/3 3, CA1/ 1,8,13 18, 113,13 1, FHS8-/37 37, 3SV1 1,1 3, 13, 133, 19, FHS8-/ 8, 3SV11 1,1 3, 1, 13,, FHS8-/ 99, 3SV13 1, 3, 198, 1, 97, The current shown is the nominal current of the set. gms_fhes_p-en_b_te

Booster sets GSD - GSY Series MARKET SECTORS CIVIL, INDUSTRIAL APPLICATIONS Water network supply in condominiums, offices, hotels, shopping centres, factories. Water supply to agricultural water networks (e.g. irrigation). GS.../FH SPECIFICATIONS Flow rate up to m 3 /h. Head up to 1 m. Electrical panel supply voltage: 3 x V ± 1%. Frequency Hz. Voltage for controls outside panel: Vac. Electrical panel protection class IP. Maximum service pump power: x kw. Motor start-up: - Direct for powers up to kw inclusive for pump (GSD/). - Star/Delta for higher powers (GSY/ set). - Softstarter, available on request (GSSF/ set). Electric pumps with horizontal axis: - FH series (motor protection class IP). Maximum operating pressure: 1 bar. Maximum temperature of pumped liquid : +8 C.

TWO-PUMP BOOSTER SETS, GSD-GSY SERIES HORIZONTAL ELECTRIC PUMPS WITH NON-RETURN VAL ALVE ON DISCHARGE SIDE GS.../FH

TWO-PUMP BOOSTER SETS, GSD-GSY SERIES HORIZONTAL ELECTRIC PUMPS WITH NON-RETURN VAL ALVE ON DISCHARGE SIDE GSD / GSY DRW N DNA DNM A B C D E F H H1 H H3 I L FHE 3-/7 1 8 19 3 9 88 7 13 19 8 117 11 37 FHE 3-/11 1 8 19 3 9 88 7 13 19 8 117 11 37 FHE 3-1/ 1 8 19 3 9 88 7 13 1 11 11 37 FHE 3-1/ 1 8 19 3 9 88 7 13 1 11 11 37 FHE 3-/3 1 8 19 3 9 88 7 13 7 1 11 37 FHE 3-/ 1 8 19 3 9 88 7 13 7 1 11 37 FHE 3-/ 1 8 19 3 389 9 7 13 7 19 973 37 FHE 3-/7 1 8 19 3 389 9 7 13 7 19 973 37 FHE -/11 1 1 19 71 37 11 88 19 1 117 9 89 FHE -/ 1 1 19 71 37 11 88 19 1 117 9 89 FHE -/ 1 1 19 71 37 11 88 19 1 117 9 89 FHE -1/3 1 1 19 71 37 11 88 1 9 13 117 9 89 FHE -1/ 1 1 19 71 37 11 88 1 9 13 117 9 89 FHE -/ 1 1 19 71 37 11 88 73 13 97 9 89 FHE -/7 1 1 19 71 37 11 88 73 13 97 9 89 FHE -/9 1 1 19 71 37 11 88 88 1 97 9 89 FHE -/11 1 1 19 71 37 11 88 88 1 97 9 89 FHE -/ 1 1 37 88 88 1 111 9 89 FHE -/ 19 71 37 118 88 1 73 13 117 9 89 FHE -/3 19 71 37 118 88 1 73 13 117 9 89 FHE -/ 19 71 37 118 88 1 73 13 117 9 89 FHE -1/ 19 71 37 118 88 78 1 97 9 89 FHE -1/7 19 71 37 118 88 78 1 97 9 89 FHE -/9 19 71 37 118 88 8 1 97 9 89 FHE -/11 19 71 37 118 88 8 1 97 9 89 FHE -/ 37 187 88 8 1 111 9 89 FHE -/18 3 8 37 7 88 3 3 88 111 9 1 FHE -/ 8 8 37 117 88 3 3 88 71 9 1 FHE-/ 3 19 71 11 18 9 19 117 9 89 FHE-/ 3 19 71 11 18 9 19 97 9 89 FHE-/7 3 19 71 11 18 9 19 97 9 89 FHE-1/9 3 19 71 11 18 9 179 97 9 89 FHE-1/11 3 19 71 11 18 9 179 97 9 89 FHE-1/ 3 11 1 9 179 111 9 89 FHE-/ 3 11 1 9 19 17 111 9 89 FHE-/18 3 3 8 11 1831 9 3 3 113 17 111 9 1 FHE-/ 3 8 8 11 1881 9 3 3 113 17 71 9 1 FHE-/ 3 8 8 11 1881 9 3 3 117 189 71 9 1 FHS-/3 3 8 9 11 1981 9 3 3 117 189 71 9 1 FHS-/37 3 8 9 11 1981 9 3 3 117 189 71 9 1 FHE8-1/11 3 19 71 8 3 98 17 181 97 9 89 FHE8-1/ 3 8 1 98 17 181 111 9 89 FHE8-1/18 3 3 8 8 193 98 3 3 1197 18 111 9 1 FHE8-/ 3 8 8 8 198 98 3 3 1 1881 71 9 1 FHS8-/3 3 8 9 8 8 98 3 3 1 191 71 9 1 FHS8-/37 3 8 9 8 8 98 3 3 17 1931 71 9 1 FHS8-/ FHS8-/ DIMENSIONS ON REQUEST DIMENSIONS ON REQUEST Dimensions in mm. Tolerance ± 1 mm. gs_fhe-en_a_td GS.../FH 7

TWO-PUMP BOOSTER SETS, GSD-GSY RA SERIES HORIZONTAL ELECTRIC PUMPS WITH NON-RETURN VAL ALVE ON SUCTION SIDE GS.../FH 8

TWO-PUMP BOOSTER SETS, GSD-GSY RA SERIES HORIZONTAL ELECTRIC PUMPS WITH NON-RETURN VAL ALVE ON SUCTION SIDE GSD / GSYRA DRW N DNA DNM A B C D E F H H1 H H3 I L FHE 3-/7 1 8 19 3 93 7 13 19 73 11 11 37 FHE 3-/11 1 8 19 3 93 7 13 19 73 11 11 37 FHE 3-1/ 1 8 19 3 93 7 13 1 13 111 11 37 FHE 3-1/ 1 8 19 3 93 7 13 1 13 111 11 37 FHE 3-/3 1 8 19 3 93 7 13 1 119 11 37 FHE 3-/ 1 8 19 3 93 7 13 1 119 11 37 FHE 3-/ 1 8 19 3 18 7 13 83 1171 973 37 FHE 3-/7 1 8 19 3 18 7 13 83 1171 973 37 FHE -/11 1 1 19 71 7 13 88 19 1 117 9 89 FHE -/ 1 1 19 71 7 13 88 19 1 117 9 89 FHE -/ 1 1 19 71 7 13 88 19 1 117 9 89 FHE -1/3 1 1 19 71 7 13 88 1 8 119 117 9 89 FHE -1/ 1 1 19 71 7 13 88 1 8 119 117 9 89 FHE -/ 1 1 19 71 77 88 33 1 97 9 89 FHE -/7 1 1 19 71 77 88 33 1 97 9 89 FHE -/9 1 1 19 71 77 88 98 13 97 9 89 FHE -/11 1 1 19 71 77 88 98 13 97 9 89 FHE -/ 1 1 77 13 88 98 13 111 9 89 FHE -/ 19 71 131 88 1 1 11 117 9 89 FHE -/3 19 71 131 88 1 1 11 117 9 89 FHE -/ 19 71 131 88 1 1 11 117 9 89 FHE -1/ 19 71 131 88 9 189 97 9 89 FHE -1/7 19 71 131 88 9 189 97 9 89 FHE -/9 19 71 131 88 89 139 97 9 89 FHE -/11 19 71 131 88 89 139 97 9 89 FHE -/ 117 88 73 13 111 9 89 FHE -/18 3 8 197 88 3 3 77 139 111 9 1 FHE -/ 8 8 177 88 3 3 77 139 71 9 1 FHE-/ 3 19 71 8 9 9 39 117 9 89 FHE-/ 3 19 71 8 9 9 39 97 9 89 FHE-/7 3 19 71 8 9 9 39 97 9 89 FHE-1/9 3 19 71 8 9 9 9 97 9 89 FHE-1/11 3 19 71 8 9 9 9 97 9 89 FHE-1/ 3 8 18 9 9 9 111 9 89 FHE-/ 3 8 18 9 97 1 111 9 89 FHE-/18 3 3 8 8 1888 9 3 3 11 1 111 9 1 FHE-/ 3 8 8 8 1938 9 3 3 11 1 71 9 1 FHE-/ 3 8 8 8 1938 9 3 3 189 71 9 1 FHS-/3 3 8 9 8 38 9 3 3 189 71 9 1 FHS-/37 3 8 9 8 38 9 3 3 189 71 9 1 FHE8-1/11 3 19 71 78 117 98 99 1 97 9 89 FHE8-1/ 3 78 17 98 99 1 111 9 89 FHE8-1/18 3 3 8 78 98 3 3 13 19 111 9 1 FHE8-/ 3 8 8 78 98 3 3 11 17 71 9 1 FHS8-/3 3 8 9 78 98 3 3 181 17 71 9 1 FHS8-/37 3 8 9 78 98 3 3 1111 177 71 9 1 FHS8-/ FHS8-/ DIMENSIONS ON REQUEST DIMENSIONS ON REQUEST Dimensions in mm. Tolerance ± 1 mm. gsra_fhe-en_a_td GS.../FH 9

GS.../FH 3

Booster sets GSD1 - GSY1 Series MARKET SECTORS CIVIL, INDUSTRIAL APPLICATIONS Water network supply in condominiums, offices, hotels, shopping centres, factories. Water supply to agricultural water networks (e.g. irrigation). GS.../FH SPECIFICATIONS Flow rate up to m 3 /h. Head up to 1 m. Electrical panel supply voltage: 3 x V ± 1%. Frequency Hz. Voltage for controls outside panel: Vac. Electrical panel protection class IP. Maximum service pump power: x kw. Motor start-up: - Direct for powers up to kw inclusive for pump (GSD/). - Star/Delta for higher powers (GSY/ set). - Softstarter, available on request (GSSF/ set). Electric pumps with horizontal axis: - FH series (motor protection class IP). Electric jockey pumps - SV and CA series (motor protection class IP). Maximum operating pressure: 1 bar. Maximum temperature of pumped liquid : +8 C. 31

TWO-PUMP BOOSTER SETS, GSD1 SERIES HORIZONTAL ELECTRIC PUMPS WITH JOCKEY PUMP NON-RETURN VAL ALVE ON DISCHARGE SIDE GS.../FH 3

TWO-PUMP BOOSTER SETS, GSD1 SERIES HORIZONTAL ELECTRIC PUMPS WITH JOCKEY PUMP NON-RETURN VAL ALVE ON DISCHARGE SIDE GSD1 DRW N DNA DNM A B C D E F H H1 H H3 I L FHE 3-/7 1 8 3 9 878 19 18 19 8 117 973 37 99 FHE 3-/11 1 8 3 9 878 19 18 19 8 117 973 37 99 FHE 3-1/ 1 8 3 9 878 19 18 1 11 973 37 99 FHE 3-1/ 1 8 3 9 878 19 18 1 11 973 37 99 FHE 3-/3 1 8 3 9 878 19 18 7 1 973 37 99 FHE 3-/ 1 8 3 9 878 19 18 7 1 973 37 99 FHE 3-/ 1 8 3 389 97 19 18 7 19 973 37 99 FHE 3-/7 1 8 3 389 97 19 18 7 19 973 37 99 FHE -/11 1 1 71 37 1 137 177 19 1 97 9 133 FHE -/ 1 1 71 37 1 137 177 19 1 97 9 133 FHE -/ 1 1 71 37 1 137 177 19 1 97 9 133 FHE -1/3 1 1 71 37 1 137 177 1 9 13 97 9 133 FHE -1/ 1 1 71 37 1 137 177 1 9 13 97 9 133 FHE -/ 1 1 71 37 117 137 177 73 13 97 9 133 FHE -/7 1 1 71 37 117 137 177 73 13 97 9 133 FHE -/9 1 1 71 37 117 137 177 88 1 71 9 133 FHE -/11 1 1 71 37 117 137 177 88 1 71 9 133 FHE -/ 1 1 37 137 177 88 1 71 9 133 FHE -/ 71 37 13 137 177 1 73 13 97 9 133 FHE -/3 71 37 13 137 177 1 73 13 97 9 133 FHE -/ 71 37 13 137 177 1 73 13 97 9 133 FHE -1/ 71 37 13 137 177 78 1 97 9 133 FHE -1/7 71 37 13 137 177 78 1 97 9 133 FHE -/9 71 37 13 137 177 8 1 71 9 133 FHE -/11 71 37 13 137 177 8 1 71 9 133 FHE -/ 37 187 137 177 8 1 71 9 133 FHE -/18 8 8 37 117 137 3 3 88 71 9 19 FHE -/ 8 8 37 117 137 3 3 88 71 9 19 FHE-/ 3 71 11 198 11 177 19 97 9 133 FHE-/ 3 71 11 198 11 177 19 97 9 133 FHE-/7 3 71 11 198 11 177 19 97 9 133 FHE-1/9 3 71 11 198 11 177 179 71 9 133 FHE-1/11 3 71 11 198 11 177 179 71 9 133 FHE-1/ 3 11 1 11 177 179 71 9 133 FHE-/ 3 11 1 11 177 19 17 71 9 133 FHE-/18 3 8 8 11 1881 11 3 3 113 17 71 9 19 FHE-/ 3 8 8 11 1881 11 3 3 113 17 71 9 19 FHE-/ 3 8 8 11 1881 11 3 3 117 189 71 9 19 FHE8-1/11 3 71 8 13 17 177 17 181 71 9 133 FHE8-1/ 3 8 1 17 177 17 181 71 9 133 FHE8-1/18 3 8 8 8 198 17 3 3 1197 18 71 9 19 FHE8-/ 3 8 8 8 198 17 3 3 1 1881 71 9 19 Dimensions in mm. Tolerance ± 1 mm. gs1_fhe-en_a_td GS.../FH 33

TWO-PUMP BOOSTER SETS, GSD1 RA SERIES HORIZONTAL ELECTRIC PUMPS WITH JOCKEY PUMP NON-RETURN VAL ALVE ON SUCTION SIDE GS.../FH 3

TWO-PUMP BOOSTER SETS, GSD1 RA SERIES HORIZONTAL ELECTRIC PUMPS WITH JOCKEY PUMP NON-RETURN VAL ALVE ON SUCTION SIDE GSD1RA DRW N DNA DNM A B C D E F H H1 H H3 I L FHE 3-/7 1 8 3 113 19 18 19 73 11 973 37 99 FHE 3-/11 1 8 3 113 19 18 19 73 11 973 37 99 FHE 3-1/ 1 8 3 113 19 18 1 13 111 973 37 99 FHE 3-1/ 1 8 3 113 19 18 1 13 111 973 37 99 FHE 3-/3 1 8 3 113 19 18 1 119 973 37 99 FHE 3-/ 1 8 3 113 19 18 1 119 973 37 99 FHE 3-/ 1 8 3 113 19 18 83 1171 973 37 99 FHE 3-/7 1 8 3 113 19 18 83 1171 973 37 99 FHE -/11 1 1 71 7 18 137 177 19 1 97 9 133 FHE -/ 1 1 71 7 18 137 177 19 1 97 9 133 FHE -/ 1 1 71 7 18 137 177 19 1 97 9 133 FHE -1/3 1 1 71 7 18 137 177 1 8 119 97 9 133 FHE -1/ 1 1 71 7 18 137 177 1 8 119 97 9 133 FHE -/ 1 1 71 77 13 137 177 33 1 97 9 133 FHE -/7 1 1 71 77 13 137 177 33 1 97 9 133 FHE -/9 1 1 71 77 13 137 177 98 13 71 9 133 FHE -/11 1 1 71 77 13 137 177 98 13 71 9 133 FHE -/ 1 1 77 13 137 177 98 13 71 9 133 FHE -/ 71 13 137 177 1 1 11 97 9 133 FHE -/3 71 13 137 177 1 1 11 97 9 133 FHE -/ 71 13 137 177 1 1 11 97 9 133 FHE -1/ 71 13 137 177 9 189 97 9 133 FHE -1/7 71 13 137 177 9 189 97 9 133 FHE -/9 71 13 137 177 89 139 71 9 133 FHE -/11 71 13 137 177 89 139 71 9 133 FHE -/ 117 137 177 73 13 71 9 133 FHE -/18 8 8 177 137 3 3 77 139 71 9 19 FHE -/ 8 8 177 137 3 3 77 139 71 9 19 FHE-/ 3 71 8 11 177 9 39 97 9 133 FHE-/ 3 71 8 11 177 9 39 97 9 133 FHE-/7 3 71 8 11 177 9 39 97 9 133 FHE-1/9 3 71 8 11 177 9 9 71 9 133 FHE-1/11 3 71 8 11 177 9 9 71 9 133 FHE-1/ 3 8 18 11 177 9 9 71 9 133 FHE-/ 3 8 18 11 177 97 1 71 9 133 FHE-/18 3 8 8 8 1938 11 3 3 11 1 71 9 19 FHE-/ 3 8 8 8 1938 11 3 3 11 1 71 9 19 FHE-/ 3 8 8 8 1938 11 3 3 189 71 9 19 FHE8-1/11 3 71 78 17 17 177 99 1 71 9 133 FHE8-1/ 3 78 17 17 177 99 1 71 9 133 FHE8-1/18 3 8 8 78 17 3 3 13 19 71 9 19 FHE8-/ 3 8 8 78 17 3 3 11 17 71 9 19 Dimensions in mm. Tolerance ± 1 mm. gs1ra_fhe-en_a_td GS.../FH 3

TWO-PUMP BOOSTER SETS, GSY1 SERIES HORIZONTAL ELECTRIC PUMPS WITH JOCKEY PUMP NON-RETURN VAL ALVE ON DISCHARGE SIDE GS.../FH GSY1 DNA DNM B C D E F H H1 H I L X Y Z FHS-/3 9 11 19 11 3 3 117 189 9 19 3 FHS-/37 9 11 19 11 3 3 117 189 9 19 3 FHS8-/3 9 8 181 17 3 3 1 191 9 19 3 FHS8-/37 9 8 181 17 3 3 17 1931 9 19 3 FHS8-/ FHS8-/ DIMENSIONS ON REQUEST DIMENSIONS ON REQUEST Dimensions in mm. Tolerance ± 1 mm. gs1_fhe8-en_a_td 3

TWO-PUMP BOOSTER SETS, GSY1 RA SERIES HORIZONTAL ELECTRIC PUMPS WITH JOCKEY PUMP NON-RETURN VAL ALVE ON SUCTION SIDE GS.../FH GSY1RA DNA DNM B C D E F H H1 H I L X Y Z FHS-/3 9 8 173 11 3 3 189 9 19 3 FHS-/37 9 8 173 11 3 3 189 9 19 3 FHS8-/3 9 78 18 17 3 3 181 17 9 19 3 FHS8-/37 9 78 18 17 3 3 1111 177 9 19 3 FHS8-/ FHS8-/ DIMENSIONS ON REQUEST DIMENSIONS ON REQUEST Dimensions in mm. Tolerance ± 1 mm. gs1ra_fhe8-en_a_td 37

GS.../FH 38

Booster sets GSD3 - GSY3 Series MARKET SECTORS CIVIL, INDUSTRIAL APPLICATIONS Water network supply in condominiums, offices, hotels, shopping centres, factories. Water supply to agricultural water networks (e.g. irrigation). GS.../FH SPECIFICATIONS Flow rate up to 3 m 3 /h. Head up to 1 m. Electrical panel supply voltage: 3 x V ± 1%. Frequency Hz. Voltage for controls outside panel: Vac. Electrical panel protection class IP. Maximum service pump power: 3 x kw. Motor start-up: - Direct for powers up to kw inclusive for pump (GSD/). - Star/Delta for higher powers (GSY/ set). - Softstarter, available on request (GSSF/ set). Electric pumps with horizontal axis: - FH series (motor protection class IP). Maximum operating pressure: 1 bar. Maximum temperature of pumped liquid : +8 C. 39

THREE-PUMP BOOSTER SETS, GSD3 SERIES HORIZONTAL ELECTRIC PUMPS WITH NON-RETURN VAL ALVE ON DISCHARGE SIDE GS.../FH

THREE-PUMP BOOSTER SETS, GSD3 SERIES HORIZONTAL ELECTRIC PUMPS WITH NON-RETURN VAL ALVE ON DISCHARGE SIDE GSD3 DRW N DNA DNM A B C D E F H H1 H H3 I L FHE 3-/7 1 8 3 3 9 113 18 19 93 1187 973 37 99 FHE 3-/11 1 8 3 3 9 113 18 19 93 1187 973 37 99 FHE 3-1/ 1 8 3 3 9 113 18 1 33 17 973 37 99 FHE 3-1/ 1 8 3 3 9 113 18 1 33 17 973 37 99 FHE 3-/3 1 8 3 3 9 113 18 81 17 973 37 99 FHE 3-/ 1 8 3 3 9 113 18 81 17 973 37 99 FHE 3-/ 1 8 3 1 3 113 18 711 13 973 37 99 FHE 3-/7 1 8 3 1 3 113 18 711 13 973 37 99 FHE -/11 71 3 118 137 177 19 8 188 97 9 133 FHE -/ 71 3 118 137 177 19 8 188 97 9 133 FHE -/ 71 3 118 137 177 19 8 188 97 9 133 FHE -1/3 71 3 118 137 177 1 78 138 97 9 133 FHE -1/ 71 3 118 137 177 1 78 138 97 9 133 FHE -/ 71 3 1 137 177 7 137 97 9 133 FHE -/7 71 3 1 137 177 7 137 97 9 133 FHE -/9 71 3 1 137 177 81 11 71 9 133 FHE -/11 71 3 1 137 177 81 11 71 9 133 FHE -/ 3 3 137 177 81 11 71 9 133 FHE -/ 71 187 137 177 1 7 138 97 9 133 FHE -/3 71 187 137 177 1 7 138 97 9 133 FHE -/ 71 187 137 177 1 7 138 97 9 133 FHE -1/ 71 187 137 177 79 18 97 9 133 FHE -1/7 71 187 137 177 79 18 97 9 133 FHE -/9 71 187 137 177 81 18 71 9 133 FHE -/11 71 187 137 177 81 18 71 9 133 FHE -/ 13 137 177 89 193 71 9 133 FHE -/18 8 8 17 137 3 3 899 33 71 9 19 FHE -/ 8 8 17 137 3 3 899 33 71 9 19 FHE-/ 3 71 38 7 17 177 1 171 97 9 133 FHE-/ 3 71 38 7 17 177 1 171 97 9 133 FHE-/7 3 71 38 7 17 177 1 171 97 9 133 FHE-1/9 3 71 38 7 17 177 171 173 71 9 133 FHE-1/11 3 71 38 7 17 177 171 173 71 9 133 FHE-1/ 3 38 11 17 177 171 173 71 9 133 FHE-/ 3 38 11 17 177 111 177 71 9 133 FHE-/18 3 8 8 38 19 17 3 3 1 18 71 9 19 FHE-/ 3 8 8 38 19 17 3 3 1 18 71 9 19 FHE-/ 3 8 8 38 19 17 3 3 11 18 71 9 19 FHE8-1/11 3 3 71 79 1 17 177 118 187 71 9 133 FHE8-1/ 3 3 79 179 17 177 118 187 71 9 133 FHE8-1/18 3 3 8 8 79 39 17 3 3 1 191 71 9 19 FHE8-/ 3 3 8 8 79 39 17 3 3 19 193 71 9 19 Dimensions in mm. Tolerance ± 1 mm. gs3_fhe-en_a_td GS.../FH 1

THREE-PUMP BOOSTER SETS, GSD3 RA SERIES HORIZONTAL ELECTRIC PUMPS WITH NON-RETURN VAL ALVE ON SUCTION SIDE GS.../FH

THREE-PUMP BOOSTER SETS, GSD3 RA SERIES HORIZONTAL ELECTRIC PUMPS WITH NON-RETURN VAL ALVE ON SUCTION SIDE GSD3RA DRW N DNA DNM A B C D E F H H1 H H3 I L FHE 3-/7 1 8 3 37 191 113 18 19 8 17 973 37 99 FHE 3-/11 1 8 3 37 191 113 18 19 8 17 973 37 99 FHE 3-1/ 1 8 3 37 191 113 18 1 111 973 37 99 FHE 3-1/ 1 8 3 37 191 113 18 1 111 973 37 99 FHE 3-/3 1 8 3 37 191 113 18 8 11 973 37 99 FHE 3-/ 1 8 3 37 191 113 18 8 11 973 37 99 FHE 3-/ 1 8 3 18 113 18 9 118 973 37 99 FHE 3-/7 1 8 3 18 113 18 9 118 973 37 99 FHE -/11 71 7 131 137 177 19 8 1178 97 9 133 FHE -/ 71 7 131 137 177 19 8 1178 97 9 133 FHE -/ 71 7 131 137 177 19 8 1178 97 9 133 FHE -1/3 71 7 131 137 177 1 98 118 97 9 133 FHE -1/ 71 7 131 137 177 1 98 118 97 9 133 FHE -/ 71 9 133 137 177 1 97 9 133 FHE -/7 71 9 133 137 177 1 97 9 133 FHE -/9 71 9 133 137 177 711 1331 71 9 133 FHE -/11 71 9 133 137 177 711 1331 71 9 133 FHE -/ 9 1383 137 177 711 1331 71 9 133 FHE -/ 71 3 117 137 177 1 3 19 97 9 133 FHE -/3 71 3 117 137 177 1 3 19 97 9 133 FHE -/ 71 3 117 137 177 1 3 19 97 9 133 FHE -1/ 71 3 117 137 177 83 1317 97 9 133 FHE -1/7 71 3 117 137 177 83 1317 97 9 133 FHE -/9 71 3 117 137 177 73 1337 71 9 133 FHE -/11 71 3 117 137 177 73 1337 71 9 133 FHE -/ 3 17 137 177 78 138 71 9 133 FHE -/18 8 8 3 18 137 3 3 788 1 71 9 19 FHE -/ 8 8 3 18 137 3 3 788 1 71 9 19 FHE-/ 3 71 9 11 17 177 931 9 97 9 133 FHE-/ 3 71 9 11 17 177 931 9 97 9 133 FHE-/7 3 71 9 11 17 177 931 9 97 9 133 FHE-1/9 3 71 9 11 17 177 91 11 71 9 133 FHE-1/11 3 71 9 11 17 177 91 11 71 9 133 FHE-1/ 3 9 17 17 177 91 11 71 9 133 FHE-/ 3 9 17 17 177 99 1 71 9 133 FHE-/18 3 8 8 9 1997 17 3 3 13 19 71 9 19 FHE-/ 3 8 8 9 1997 17 3 3 13 19 71 9 19 FHE-/ 3 8 8 9 1997 17 3 3 181 17 71 9 19 FHE8-1/11 3 3 71 773 17 17 177 13 179 71 9 133 FHE8-1/ 3 3 773 1773 17 177 13 179 71 9 133 FHE8-1/18 3 3 8 8 773 13 17 3 3 13 179 71 9 19 FHE8-/ 3 3 8 8 773 13 17 3 3 188 177 71 9 19 Dimensions in mm. Tolerance ± 1 mm. gs3ra_fhe-en_a_td GS.../FH 3

THREE-PUMP BOOSTER SETS, GSY3 SERIES HORIZONTAL ELECTRIC PUMPS WITH NON-RETURN VAL ALVE ON DISCHARGE SIDE GS.../FH GSY3 DNA DNM B C D E F H H1 H I L X Y Z FHS-/3 9 38 17 17 3 3 11 18 9 19 3 FHS-/37 9 38 17 17 3 3 11 18 9 19 3 FHS8-/3 3 9 79 18 17 3 3 19 19 9 19 3 FHS8-/37 3 9 79 18 17 3 3 199 198 9 19 3 FHS8-/ FHS8-/ DIMENSIONS ON REQUEST DIMENSIONS ON REQUEST Dimensions in mm. Tolerance ± 1 mm. gs3_fhe8-en_a_td

THREE-PUMP BOOSTER SETS, GSY3 RA SERIES HORIZONTAL ELECTRIC PUMPS WITH NON-RETURN VAL ALVE ON SUCTION SIDE GS.../FH GSY3RA DNA DNM B C D E F H H1 H I L X Y Z FHS-/3 9 9 181 17 3 3 181 17 9 19 3 FHS-/37 9 9 181 17 3 3 181 17 9 19 3 FHS8-/3 3 9 773 1918 17 3 3 118 179 9 19 3 FHS8-/37 3 9 773 1918 17 3 3 1138 18 9 19 3 FHS8-/ FHS8-/ DIMENSIONS ON REQUEST DIMENSIONS ON REQUEST Dimensions in mm. Tolerance ± 1 mm. gs3ra_fhe8-en_a_td

BOOSTER SETS, GS.../FH SERIES OPERATING CHARACTERISTICS S AT Hz (JOCKEY PUMP) 3SV..3SV1 9 [rpm] ISO 99 - Annex A 1 Q [Imp gpm] 1 Q [US gpm] H [m] 18 H [ft] 1 1 1 19 1 1 GS.../FH 1 8,1 1 1 1 13 11 9 8 7 3 3 1 7 P p [kw],8 kw/stage, 3 1 1 3 Q [m 3 /h] NPSH [m] η 1 3 7 8 Q [l/min] η [%] NPSH [ft] 798_C_CH The performance curves do not take into account flow resistance in the valves and piping. The curves show performance with one pump running. These performances are valid for liquids with density ρ = 1. kg/dm³ and kinematic viscosity ν = 1 mm²/s.

BOOSTER SETS, GS.../FH SERIES OPERATING CHARACTERISTICS S AT Hz (SERVICE PUMP) GS.../FH The performance curves do not take into account flow resistance in the valves and piping. The curves show the performance with one, two and three pumps running. These performances are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm /s. The declared NPSH values are laboratory values: for practical use we recommend increasing these values by. m. 7

BOOSTER SETS, GS.../FH SERIES OPERATING CHARACTERISTICS S AT Hz (SERVICE PUMP) GS.../FH The performance curves do not take into account flow resistance in the valves and piping. The curves show the performance with one, two and three pumps running. These performances are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm /s. The declared NPSH values are laboratory values: for practical use we recommend increasing these values by. m. 8

BOOSTER SETS, GS.../FH SERIES OPERATING CHARACTERISTICS S AT Hz (SERVICE PUMP) GS.../FH The performance curves do not take into account flow resistance in the valves and piping. The curves show the performance with one, two and three pumps running. These performances are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm /s. The declared NPSH values are laboratory values: for practical use we recommend increasing these values by. m. 9

BOOSTER SETS, GS.../FH SERIES OPERATING CHARACTERISTICS S AT Hz (SERVICE PUMP) FH -/ ~ 9 [rpm] ISO 99 - Annex A 1 3 Q [Imp gpm] 1 3 Q [US 7 gpm] H [m] H [ft] 18 1 1 1 3 1 GS.../FH NPSH [m] 8 1 P P 3 P 8 NPSH [ft] 1 8 1 1 1 Q [m 3 1 /h] 1 Q [l/min] 713_A_CH The performance curves do not take into account flow resistance in the valves and piping. The curves show the performance with one, two and three pumps running. These performances are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm /s. The declared NPSH values are laboratory values: for practical use we recommend increasing these values by. m.

BOOSTER SETS, GS.../FH SERIES OPERATING CHARACTERISTICS S AT Hz (SERVICE PUMP) GS.../FH The performance curves do not take into account flow resistance in the valves and piping. The curves show the performance with one, two and three pumps running. These performances are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm /s. The declared NPSH values are laboratory values: for practical use we recommend increasing these values by. m. 1

BOOSTER SETS, GS.../FH SERIES OPERATING CHARACTERISTICS S AT Hz (SERVICE PUMP) GS.../FH The performance curves do not take into account flow resistance in the valves and piping. The curves show the performance with one, two and three pumps running. These performances are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm /s. The declared NPSH values are laboratory values: for practical use we recommend increasing these values by. m.

BOOSTER SETS, GS.../FH SERIES OPERATING CHARACTERISTICS S AT Hz (SERVICE PUMP) GS.../FH The performance curves do not take into account flow resistance in the valves and piping. The curves show the performance with one, two and three pumps running. These performances are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm /s. The declared NPSH values are laboratory values: for practical use we recommend increasing these values by. m. 3

BOOSTER SETS, GS.../FH SERIES OPERATING CHARACTERISTICS S AT Hz (SERVICE PUMP) GS.../FH The performance curves do not take into account flow resistance in the valves and piping. The curves show the performance with one, two and three pumps running. These performances are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm /s. The declared NPSH values are laboratory values: for practical use we recommend increasing these values by. m.

BOOSTER SETS, GS.../FH SERIES OPERATING CHARACTERISTICS S AT Hz (SERVICE PUMP) GS.../FH The performance curves do not take into account flow resistance in the valves and piping. The curves show the performance with one, two and three pumps running. These performances are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm /s. The declared NPSH values are laboratory values: for practical use we recommend increasing these values by. m.

BOOSTER SETS, GS.../FH SERIES OPERATING CHARACTERISTICS S AT Hz (SERVICE PUMP) GS.../FH FH -/3 ~ 9 [rpm] ISO 99 - Annex A FH -/37 ~ 9 [rpm] ISO 99 - Annex A 1 Q [Imp gpm] 1 Q [Imp gpm] 1 Q [US gpm] 9 1 Q [US gpm] 1 H [m] 8 H [m] H [ft] 8 H [ft] 9 3 7 8 7 1 P P 3 P 18 1 P P 3 P 1 1 NPSH [m] 8 NPSH [ft] NPSH [m] 8 NPSH [ft] 1 1 1 3 Q [m 3 /h] Q 8 [l/min] 77_A_CH 1 3 Q [m 3 /h] Q 8 [l/min] 77_A_CH The performance curves do not take into account flow resistance in the valves and piping. The curves show the performance with one, two and three pumps running. These performances are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm /s. The declared NPSH values are laboratory values: for practical use we recommend increasing these values by. m.

BOOSTER SETS, GS.../FH SERIES OPERATING CHARACTERISTICS S AT Hz (SERVICE PUMP) FH 8-1/11 ~ 9 [rpm] ISO 99 - Annex A FH 8-1/ ~ 9 [rpm] ISO 99 - Annex A 1 Q [Imp gpm] 1 Q [US 3 gpm] 3 1 Q [Imp gpm] 1 Q [US 3 gpm] H [m] H [ft] H [m] 1 8 3 H [ft] 3 1 8 NPSH [m] 1 8 1 P P 3 P NPSH [ft] NPSH [m] 1 8 1 P P 3 P NPSH [ft] GS.../FH 1 1 1 3 Q [m 3 7 /h] 8 1 Q [l/min] 777_A_CH 1 3 Q [m 3 7 /h] 8 1 Q [l/min] 778_A_CH FH 8-1/18 ~ 9 [rpm] ISO 99 - Annex A FH 8-/ ~ 9 [rpm] ISO 99 - Annex A 1 Q [Imp gpm] 1 Q [US 3 gpm] 1 Q [Imp gpm] 1 Q [US 3 gpm] 18 H [m] 1 H [ft] H [m] H [ft] 1 3 1 1 3 1 3 1 8 3 1 1 P P 3 P 1 P P 3 P 8 NPSH [m] 8 NPSH [ft] NPSH [m] 8 NPSH [ft] 1 1 1 3 Q [m 3 7 /h] 8 1 Q [l/min] 779_A_CH 1 3 Q [m 3 7 /h] 8 1 Q [l/min] 77_A_CH The performance curves do not take into account flow resistance in the valves and piping. The curves show the performance with one, two and three pumps running. These performances are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm /s. The declared NPSH values are laboratory values: for practical use we recommend increasing these values by. m. 7

BOOSTER SETS, GS.../FH SERIES OPERATING CHARACTERISTICS S AT Hz (SERVICE PUMP) FH 8-/3 ~ 9 [rpm] ISO 99 - Annex A FH 8-/37 ~ 9 [rpm] ISO 99 - Annex A 1 Q [Imp gpm] 1 Q [US 3 gpm] 7 1 Q [Imp gpm] 1 Q [US 3 gpm] 8 H [m] H [ft] H [m] 7 H [ft] 18 18 1 1 GS.../FH NPSH [m] 3 8 1 P P 3 P 1 1 NPSH [ft] NPSH [m] 3 8 1 P P 3 P 1 1 1 NPSH [ft] 1 1 1 3 Q [m 3 7 /h] 8 1 Q [l/min] 771_A_CH 1 3 Q [m 3 7 /h] 8 1 Q [l/min] 77_A_CH FH 8-/ ~ 9 [rpm] ISO 99 - Annex A FH 8-/ ~ 9 [rpm] ISO 99 - Annex A 1 Q [Imp gpm] 1 Q [Imp gpm] 1 Q [US 3 gpm] 9 1 Q [US 3 gpm] 1 H [m] 8 8 H [ft] H [m] 9 3 H [ft] 3 7 8 8 18 7 1 1 P P 3 P 1 P P 3 P NPSH [m] 8 1 NPSH [ft] NPSH [m] 8 NPSH [ft] 1 1 1 3 Q [m 3 7 /h] 8 1 Q [l/min] 773_A_CH 1 3 Q [m 3 7 /h] 8 1 Q [l/min] 77_A_CH The performance curves do not take into account flow resistance in the valves and piping. The curves show the performance with one, two and three pumps running. These performances are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm /s. The declared NPSH values are laboratory values: for practical use we recommend increasing these values by. m. 8

BOOSTER SETS, GS.../FH SERIES Hc PRESSURE SURE DROP CURVE FH 3 SUCTION SIDE FH 3 DISCHARGE SIDE 8 1 Q [Imp gpm] 8 1 Q [Imp gpm] 8 1 1 Q [US gpm],1 Hc [m] Hc [ft],3 Hc [m] 8 1 1 Q [US gpm] 1 Hc [ft] 3,8 A, 8 A,,,,,1 1,,,,,1 Hc [m] 3 Col 1 vs Col Col vs Col 1 Col vs Col 1 B 1 1 8 Hc [ft] Hc [m],8,, Col 1 vs Col Col vs Col 1 Col vs Col 1 B,3,,, Hc [ft] GS.../FH 1,,1, 1 Q [m 3 3 /h] 1 3 Q [l/min] 77_A_CH,, 1 Q [m 3 3 /h] 1 3 Q [l/min] 771_A_CH FH SUCTION SIDE FH DISCHARGE SIDE 1 Q [Imp gpm] 1 Q [US gpm],1 Hc [m] Hc [ft],3 Hc [m] 1 Q [Imp gpm] 1 Q [US gpm] Hc [ft],8 A,,,,, 1 A 3,,1, 1, Hc [m] 3 1 Col 1 vs Col Col vs Col 1 Col vs Col 1 B, 1 1 1 1 8 Hc [ft],1 Hc [m],8,,, Col 1 vs Col Col vs Col 1 Col vs Col 1 B,3, Hc [ft],,,1, 1 3 Q [m 3 /h] 8 Q [l/min] 1 777_A_CH,, 1 3 Q [m 3 /h] 8 Q [l/min] 1 77_A_CH The declared curves are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. Hc (A): Pressure drop curve with check valve installed on the delivery side of the pump. Hc (B): Pressure drop curve with check valve installed on the suction side of the pump. The pressure drops do not consider the pressure drops distributed in the manifold. 9

BOOSTER SETS, GS.../FH SERIES Hc PRESSURE SURE DROP CURVE FH SUCTION SIDE FH DISCHARGE SIDE 1 3 Q [Imp gpm] 1 3 Q [Imp gpm] 1 3 Q [US gpm],,1 Hc [m],1,,1 Hc [ft] Hc [m] 1 3 Q [US gpm] 1 3 1 A Hc [ft],3 A,1 8,,1,8,,, 1 GS.../FH, Hc [m] 1 Col 1 vs Col Col vs Col 1 Col vs Col 1 B, 3 Hc [ft] Hc [m],1,1,1,8, Col 1 vs Col Col vs Col 1 Col vs Col 1 B,,3, Hc [ft] 1,,,1 8 Q [m1 3 /h] 8 1 1 1 1 Q [l/min] 778_A_CH,, 8 Q [m1 3 /h] 8 1 1 1 1 Q [l/min] 773_A_CH FH SUCTION SIDE FH DISCHARGE SIDE 1 3 Q [Imp gpm] 1 3 Q [Imp gpm] Hc [m] 1 3 Q [US gpm] 7 1 1 1 Hc [ft] Hc [m] 1 3 Q [US gpm] 7 8 Hc [ft] A 3 A 1 8 1 1 Hc [m] Col 1 vs Col Col vs Col 1 Col vs Col 1 8 7 Hc [ft] Hc [m] 1 8 Col 1 vs Col Col vs Col 1 Col vs Col 1 B 3 Hc [ft] B 1 3 1 1 8 1 1 1 Q [m1 3 /h] 1 Q [l/min] 779_A_CH 8 1 1 1 Q [m1 3 /h] 1 Q [l/min] 77_A_CH The declared curves are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. Hc (A): Pressure drop curve with check valve installed on the delivery side of the pump. Hc (B): Pressure drop curve with check valve installed on the suction side of the pump. The pressure drops do not consider the pressure drops distributed in the manifold.

BOOSTER SETS, GS.../FH SERIES Hc PRESSURE SURE DROP CURVE FH 8 SUCTION SIDE FH 8 DISCHARGE SIDE 1 3 Q [Imp gpm] 1 3 Q [Imp gpm] Hc [m] 1 3 Q [US gpm] 7 Hc [ft] 1 Hc [m] 1 3 Q [US gpm] 7 8 Hc [ft] 3 1 A 8 1 A 1 1 Hc [m] 1 Col 1 vs Col Col vs Col 1 Col vs Col 1 B 3 Hc [ft] Hc [m] 8 Col 1 vs Col Col vs Col 1 Col vs Col 1 B 3 Hc [ft] GS.../FH 1 1 1 Q [m 3 /h] 1 3 Q [l/min] 771_A_CH 1 Q [m 3 /h] 1 3 Q [l/min] 77_A_CH The declared curves are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. Hc (A): Pressure drop curve with check valve installed on the delivery side of the pump. Hc (B): Pressure drop curve with check valve installed on the suction side of the pump. The pressure drops do not consider the pressure drops distributed in the manifold. 1

GS.../FH

GS.../SH Series Fixed-speed pressure booster sets Horizontal Centrifugal electric pumps SH series in AISI 31 Stainless Steel in compliance EN 733 equipped with high efficiency PLM motors flow rate up to m 3 /h Hz GS.../SH 3

GS.../SH SERIES HYDRAULIC PERFORMANCE RANGE AT Hz Q [Imp gpm] 8 1 3 8 1 3 8 1 3 8 1 Q [US gpm] 3 1 8 3 H [m] GS.../SH H [ft] 1 8 7 1 8 3 GS.../SH 1 3 8 1 Q [m 3 /h] 3 8 1 3 8 1 Q [l/min] 3 8 1 78_A_CH

RANGE The GS series of fixed-speed pressure boosters comprises models with or 3 electric service pumps and an optional jockey pump in order to satisfy the specific needs of every application. GS SETS Fixed-speed sets with two horizontal service pumps, SH series, with power ratings up to 37 kw. Head up to 1m. Flow rate up to m 3 /h. GS1 SETS Fixed-speed sets with two service pumps and a jockey pump. Horizontal service electric pumps, SH series, with power ratings up to 37 kw. Head up to 1m. Flow rate up to m 3 /h. GS.../SH GS3 SETS Fixed-speed sets with three horizontal service pumps, SH series, with power ratings up to 37 kw. Head up to 1m. Flow rate up to m 3 /h.

CHARACTERISTICS S OF THE ELECTRIC PUMPS The SH series comprises single-stage centrifugal pumps in pressed AISI 31 stainless steel. The hydraulic sizes and the diameters of the suction and delivery ports comply with EN 733 (ex DIN ). Flange sizes comply with EN 19-1. Available sizes: DN to DN 8. Motor: enbloc motor/pump coupling with bracket with impeller directly splined onto the motor shaft protrusion (SHE) or with joint, adaptor and rigid joint splined onto the shaft protrusion of normalised motors (SHS). Technical data: Flow rate: up to m 3 /h ( poles). 13 m 3 /h ( poles). Head: up to 11 m ( poles). 3 m ( poles). GS.../SH Temperature of pumped liquid: Standard from -1 C to +1 C. Special versions available on request. Maximum operating pressure:1 bar (PN 1). Mechanical seal Mechanical seal as per EN17 (ex DIN 9). Anti-clockwise rotation looking at the pump from the suction port side. Motor Asynchronous three-phase, squirrel cage rotor, closed construction and externally ventilated. Performance levels according to EN 3-1. Standard LOWARA motors up to 11 kw (inclusive) for the -pole version and up to kw (inclusive) for the -pole version. Other brands for higher power ratings. The performance levels of PLM surface motors lie within what is usually referred to as efficiency class 1. Protection class IP. Insulation class F. Max. ambient temperature C. For different environmental conditions check the power rating. Condensate drain plugs on all motors. Standard voltage: Single-phase - Vac, Hz Three-phase version: -/38- Vac Hz for power ratings up to 3 kw; 38-/-9 Vac, Hz for power ratings higher than 3 kw.

CHARACTERISTICS S OF THE ELECTRIC PUMPS USED IN THE GS SERIES OF PRESSURE SURE BOOSTER SETS HORIZONTAL AL ELECTRIC PUMPS SERIES: SHE 3,,,, 8 SERIES Single impeller cast iron horizontal centrifugal with pump body and shaft made of AISI 31L stainless steel. Closed impeller made of AISI 31L stainless steel laser technology welded (for sizes, 3,,, -1/7 and -1/11A) or AISI CF8M cast stainless steel. Hydraulic sizes and nominal diameter DN of suction and discharge ports according to EN 733 (ex DIN ). Flanges according to EN 19- (ex UNI 3) and DIN 3. Motor coupling: SHE, enbloc via joint with rotor directly splined onto the motor shaft protrusion. SHS, via joint, adaptor and rigid joint splined onto the protrusion of normalised motor shafts. The performance levels of PLM surface motors lie within what is usually referred to as efficiency class 1. Performance levels according to EN 3-1. Booster sets drinking water use (DW version), pump has to have Ceramic, Carbon, EPDM seals. GS.../SH 7

OPERATING CHARACTERISTICS S AND LIMITS Liquids handled Water containing no gas or corrosive and/or aggressive substances. Fluid temperature Above -1 C a + 8 C Ambient temperature Above C a + C Maximum operating pressure 1 bar * Minimum inlet pressure According to NPSH curve and losses, with a minimum margin of. m Maximum inlet pressure The inlet pressure added to the pressure of the pump at zero flow must be lower than the maximum operating pressure of the set. Installation Indoors, protected from the weather. Away from heat sources. Max elevation 1 m ASL. Max humidity % without condensation., kw Pn 3 kw max starts per hour. Direct motor start; kw Pn 7, kw max starts per hour. Direct motor start; Hourly starts (single pump) 11 kw Pn kw max 3 starts per hour. Direct motor start; 18, kw Pn kw max starts per hour. Direct motor start; 3 kw Pn 37 kw max 1 starts per hour. Start/delta start; Pn = kw max 8 starts per hour. Start/delta start; Sound emission See table * On request, PN above in function of the service gfixo_p-en_b_ti If there's jockey pump, PN can be lower GS.../SH SOUND EMISSION SION LEVELS P (kw) IEC* G.. G..3,7 9R <7 <7 1,1 9R <7 <7 1, 9R <7 <7, 9R <7 <7 3 9 <7 7 11R 7 7, 11 71 73 7, 11 7 7 9, 13 7 78 11 13 7 78 1 7 7 18, 1 7 78 18R 73 7 3 83 8 37 83 8 87 89 87 89 * R=Reduced motor casing size with respect to shaft extension and related flange. gsfixo_p-en_a_tr ** Noise value of the electric motor only. Hz 9 rpm LpA (db ±)** 8

MAIN COMPONENTS Main on-off valves fitted to the suction and delivery lines of each pump, ball type with threaded connectors up to series SH, butterfly type for SH and SH 8 pumps. Check valve on the delivery side of each pump, spring type with threaded connected up to ", double-swing type between flanges over ". For applications with air-cushion autoclaves, the check valves are mounted on the suction side and the unit is fitted with a G 1/" threaded hose connector for the air supply (GS RA series). Suction manifold in AISI 3 stainless steel, threaded or flanged depending on the type of pump (see drawings). Threaded water inlet connector. Delivery manifold in AISI 3 stainless steel, threaded or flanged depending on the type of pump (see drawings). Threaded R1" connectors with relative caps for connecting -litre expansion vessels. Pressure gauge and two control transmitters located on the delivery side of the unit. Various fittings in nickel-plated brass, galvanised steel or stainless steel depending on the version. Support base for pump unit and board bracket in painted steel. Control panel protected to IP. AVAILABLE AILABLE STANDARD VERSIONS See material table. STANDARD VERSION For or general use Ball valves in nickel-plated brass, butterfly valves in polyamide, check valves in brass or painted cast-iron with flaps in steel, plugs, splines and flanges galvanised steel; manifolds in A3. AISI 3 VERSION (GS../A3), AISI 31 (GS../A31) For special uses The manifolds, valves, check valves and the main elements with parts in direct contact with the fluid are made of AISI 3 or AISI 31 stainless steel. Optional accessories: Dry-running prevention devices in one of the following versions: - float switch, for negative heads; - pack of probe electrodes, for positive heads. Autoclaves in the following versions: - Air-cushion autoclaves with compressor and accessories for autoclave and compressor. - Diaphragm autoclaves instead of air-cushion versions. lt diaphragm expansion vessel with ball valve (one for each pump) in the following versions, depending on the maximum head of the pumps: - Hydro tube kit L 8 bar - Hydro tube kit L 1 bar - Hydro tube kit L 1 bar Alarms kit; Air suction for RA version; Air compressor for RA version; SPECIAL VERSIONS AVAILABLE AILABLE ON REQUEST (Contact the Sales and technical Assistance Service) Units with non-standard input voltages, such as three-phase 3x3V, 3xV. Units with single-phase input voltages 1x3V. Jockey pump other than the standard ones illustrated in the catalogue. Support base in AISI 3, AISI 31 stainless steel. Units with stainless steel expansion vessels. Units with special valves. Units with electric pumps (GS...). Units with electric pumps (GS1... GS...). GS.../SH DW VERSION (GS../DW) For use with drinking water The main components in contact with the fluid are certified for drinking water or made from AISI 3 or superior stainless steel. Valves in nickel-plated brass, butterfly valves in epoxy, check valves with flaps in AISI 3 steel; manifolds in A3. 9

TABLE OF MATERIALS FOR SETS WITH SH -3-- PUMPS NAME MATERIAL (STANDARD) DW A3 A31 Manifolds AISI 3 AISI 3 AISI 3 AISI 31 On-off valves Nickel-plated brass Nickel-plated brass for AISI 3 drinking water AISI 31 Non-return valves AISI 3 AISI 3 AISI 3 AISI 31 Pressure switches Chrome plated zinc alloy AISI 3 AISI 3 AISI 3 Pressure transmitters AISI 31 AISI 31 AISI 31 AISI 31 Nipples/caps/plugs/flanges Galvanized steel AISI 31 AISI 31 AISI 31 Bracket Painted steel Painted steel Painted steel Painted steel Base Painted steel Painted steel Painted steel Painted steel Electric pump body AISI 31 AISI 31 AISI 31 AISI 31 gfixosh_p-en_a_tm GS.../SH TABLE OF MATERIALS FOR SETS WITH SHE/SHS -8 PUMPS NAME MATERIAL (STANDARD) DW A3 A31 Manifolds AISI 3 AISI 3 AISI 3 AISI 31 On-off valves Polyamide Polyamide AISI 3 AISI 31 Non-return valves Painted cast-iron with stainless steel flaps Painted cast-iron with stainless steel flaps AISI 3 AISI 31 Pressure switches Chrome plated zinc alloy AISI 3 AISI 3 AISI 3 Pressure transmitters AISI 31 AISI 31 AISI 31 AISI 31 Nipples/caps/plugs/flanges Galvanized steel AISI 31 AISI 31 AISI 31 Bracket Painted steel Painted steel Painted steel Painted steel Base Painted steel Painted steel Painted steel Painted steel Electric pump body AISI 31 AISI 31 AISI 31 AISI 31 gfixosh-8_p-en_a_tm 7

GS.../SH SERIES BOOSTER SETS HYDRAULIC PERFORMANCE TABLE AT HZ (JOCKEY PUMP) PUMP NOMINAL Q = DELIVERY TYPE POWER l/min 1 3 3 73 m 3 /h,7 1, 1, 1,8,1,,7 3, 3,, kw HP H = TOTAL HEAD METRES COLUMN OF WATER 3SV,37, 1, 1,3 1, 13, 13, 1, 11,7 9,8, 3SV3,37, 1,,8,3 19, 18,7 17,7 1, 13,7 8, 3SV,37, 9 7,7 7,1,, 3,9,,8 1,8 1,1 3SV,,7 37 3, 3,8 3, 33,9 3, 31,1 9,, 1, 3SV,,7 3,, 1,, 38, 3, 3,3 8, 18, 3SV7,,7 3 1,8 1,, 8,7 7,,, 3,1, 3SV8,7 1 9,1 8, 7,, 3, 1, 8,1,7 7, 3SV9 1,1 1, 8,8,8,,8, 7,9,, 31, 3SV1 1,1 1, 7 73,8 7,7 71,3 9,3,9 3,8, 1, 3, 3SV11 1,1 1, 8 81, 79,7 78, 7,8 73,1 9,7,7, 37, 3SV1 1,1 1, 9 87,8 8, 8, 8,1 79,1 7, 71,1 9,9,1 3SV13 1, 98 9,7 9, 93, 91, 87,8 83,9 79, 7,, 3SV1 1, 1 1,1 1, 1, 97,7 9, 89,9 8,8 71,8 8, 3SV1 1, 1 117,8 11,1 113, 11, 1, 11, 9,8 8,9, 3SV19, 3 1 1,3 1,3 137, 133,9 19, 13, 11,7 99,1 7, 3SV1, 3 9 7 1 17 1 13 18 18 7 gfix_fhe_pp_3sv-p-en_a_th PUMP TYPE NOMINAL Q = DELIVERY POWER l/min 3 7 8 1 1 m 3 /h 1,8, 3 3,,,8 7, 9 kw HP H = TOTAL HEAD METRES COLUMN OF WATER CA 7/33,7 1,9 38,8 3,9 3, 31,7 8, 3,9 CA 7/3,9 1, 8,8,1 3,,7 37,7 3, 9, CA 7/ 1,1 1,,, 9,8 7,1 3,9 39,9 3,3 CA 1/, 3 3,8 9, 8,,,8,,7 37,1 GS.../SH Performance according to ISO 99 - Annex A. 99_pp_ca-p-en_a_th 71

GS.../SH GS/SH, GS1/SH SERIES BOOSTER SETS HYDRAULIC PERFORMANCE TABLE AT HZ (SERVICE PUMP) SET NOMINAL Q = DELIVERY TYPE POWER l/min 3 8 9 1 1 1 18 3 3 3 7 GS/.. m 3 /h 18 3 3 8 7 8 9 18 1 1 18 1 3 378 kw H = TOTAL HEAD METRES COLUMN OF WATER SHE-/ x, 9,,8 3,8,3 31,9 7 SHE./ x, 1,,8 3,,3 7 39, SHE-/7 x 7, 7,9 9,3, 3, 9, 1,1 SHE-/11 x 11 87, 81, 78,7 7, 71,8 3,3 8, SHE3-/7, x,7 1, 1, 13, 11,3 9, SHE3-/11 x 1,1 1, 19, 17,8 1, 1, 9,8 SHE3-1/ x 1, 7,,,7, 18,1 1,7 SHE3-1/ x, 3, 3, 31, 9,, 1, 18, SHE3-/3 x 3 3,7 38, 3, 33, 3,,3 SHE3-/ x 3, 9,,8, 1, 33,8 8,8 SHE3-/ x, 1,7,7, 1, 7,9, SHE3-/7 x 7, 7,1 8,9, 3,,, SHE3-/11 x 11 8, 8,1 77, 7,3 71, 3,3 9 SHE-/11 x 1,1 1, 1, 1,9 1, 7, SHE-/ x 1, 17, 1, 1, 13 1, 8, SHE-/ x,,3,, 19,,9 13, SHE-1/3 x 3 3, 9,,9,8 17, SHE-1/ x 38, 3, 33, 31,7,7,8 18, SHE-/ x, 9,1, 3,8 3, 31,, SHE-/7 x 7, 8,,1,3,8,, 3, SHE-/9 x 9,,9, 9, 8 1,, SHE-/11 x 11 7,7 71, 9, 7,8 1,, SHE-/ x 87,7 8, 81, 8 7,3 9,, SHE-/ x, 17, 1, 13, 1, 11, 9,, SHE-/3 x 3 1,7 18,8 17, 1,3 1,8 13, 1, SHE-/ x,7 3,3,,8 19,3 18,, SHE-1/ x, 3,1 3, 9, 7, 8,, 19,8 SHE-1/7 x 7,,8 37, 3, 3,8,8, 7, 18, SHE-/9 x 9, 3, 7,,3,8, 3,8 9,8 SHE-/11 x 11,1,,8,3 7,,3 37, SHE-/ x 7,,, 3,3 1, 8,3 1, SHE-/18 x 18, 8, 7, 73, 71, 9,,3 9, SHE-/ x 88,9 8, 8,8 8,7 78, 7,8 9, SHE-1/ x 19, 1,8 1,, 13, 1,8 7, SHE-1/ x,, 1,,7 19,8 18,, 11,8 SHE-1/7 x 7, 8,,,3,7 3,, 1,8 1, SHE-1/9 x 9, 38, 3, 3,3 33, 3,,, SHE-1/11 x 11 3,,8 39,8 38, 3, 3,, 1, SHE-/ x 3, 8,8 7,,3 38, 3, SHE-/18 x 18,,,,3, 7,, 3, SHE-/ x 8,, 3,3,, 9,, SHS-/3 x 3 8,3 81,7 79, 7, 9,, SHS-/37 x 37 98, 9,3 93, 88, 8, 78, SHE8-1/11 x 11 33, 31,9 3, 7,,, 1, SHE8-1/ x,3 38,8 37, 3, 33, 7,, SHE8-1/18 x 18, 7,,7, 1,, 3, 7, 19, SHE8-/ x 3, 9,8 7,, 1, 33, SHS8-/3 x 3 3, 1, 9, 7,,, 3, SHS8-/37 x 37 71, 9, 7,, 1, 3,, The table refers to performance with pumps running. gms_psh_p-en_a_th 7

GS3/SH SERIES BOOSTER SETS HYDRAULIC PERFORMANCE TABLE AT HZ (SERVICE PUMP) SET NOMINAL Q = DELIVERY TYPE POWER l/min 7 9 1 13 18 1 7 3 3 7 9 111 GS3/.. m 3 /h 7 3 7 81 18 1 1 1 18 1 7 3 3 7 kw SHE- 3 x, 9,,8 3,8,3 31,9 7 SHE. 3 x, 1,,8 3,,3 7 39, SHE- 3 x 7, 7,9 9,3, 3, 9, 1,1 SHE- 3 x 11 87, 81, 78,7 7, 71,8 3,3 8, SHE3-3 x,7 1, 1, 13, 11,3 9, SHE3-3 x 1,1 1, 19, 17,8 1, 1, 9,8 SHE3-1 3 x 1, 7,,,7, 18,1 1,7 SHE3-1 3 x, 3, 3, 31, 9,, 1, 18, SHE3-3 x 3 3,7 38, 3, 33, 3,,3 SHE3-3 x 3, 9,,8, 1, 33,8 8,8 SHE3-3 x, 1,7,7, 1, 7,9, SHE3-3 x 7, 7,1 8,9, 3,,, SHE3-3 x 11 8, 8,1 77, 7,3 71, 3,3 9 SHE- 3 x 1,1 1, 1, 1,9 1, 7, SHE- 3 x 1, 17, 1, 1, 13 1, 8, SHE- 3 x,,3,, 19,,9 13, SHE-1 3 x 3 3, 9,,9,8 17, SHE-1 3 x 38, 3, 33, 31,7,7,8 18, SHE- 3 x, 9,1, 3,8 3, 31,, SHE- 3 x 7, 8,,1,3,8,, 3, SHE- 3 x 9,,9, 9, 8 1,, SHE- 3 x 11 7,7 71, 9, 7,8 1,, SHE- 3 x 87,7 8, 81, 8 7,3 9,, SHE- 3 x, 17, 1, 13, 1, 11, 9,, SHE- 3 x 3 1,7 18,8 17, 1,3 1,8 13, 1, SHE- 3 x,7 3,3,,8 19,3 18,, SHE-1 3 x, 3,1 3, 9, 7, 8,, 19,8 SHE-1 3 x 7,,8 37, 3, 3,8,8, 7, 18, SHE- 3 x 9, 3, 7,,3,8, 3,8 9,8 SHE- 3 x 11,1,,8,3 7,,3 37, SHE- 3 x 7,,, 3,3 1, 8,3 1, SHE- 3 x 18, 8, 7, 73, 71, 9,,3 9, SHE- 3 x 88,9 8, 8,8 8,7 78, 7,8 9, SHE-1 3 x 19, 1,8 1,, 13, 1,8 7, SHE-1 3 x,, 1,,7 19,8 18,, 11,8 SHE-1 3 x 7, 8,,,3,7 3,, 1,8 1, SHE-1 3 x 9, 38, 3, 3,3 33, 3,,, SHE-1 3 x 11 3,,8 39,8 38, 3, 3,, 1, SHE- 3 x 3, 8,8 7,,3 38, 3, SHE- 3 x 18,,,,3, 7,, 3, SHE- 3 x 8,, 3,3,, 9,, SHS- 3 x 3 8,3 81,7 79, 7, 9,, SHS- 3 x 37 98, 9,3 93, 88, 8, 78, SHE8-1 3 x 11 33, 31,9 3, 7,,, 1, SHE8-1 3 x,3 38,8 37, 3, 33, 7,, SHE8-1 3 x 18, 7,,7, 1,, 3, 7, 19, SHE8-3 x 3, 9,8 7,, 1, 33, SHS8-3 x 3 3, 1, 9, 7,,, 3, SHS8-3 x 37 71, 9, 7,, 1, 3,, The table refers to performance with 3 pumps running. H = TOTAL HEAD METRES COLUMN OF WATER gms_3psh_p-en_a_th GS.../SH 73

GS, GS1, GS3/SH SERIES BOOSTER SETS ELECTRICAL DATA A TABLE AT Hz SERVICE JOCKEY PUMP PUMP 3 X V 3 X V CURRENT ABSORBED BY SET 3 X V GS.../SH TYPE Pn In TYPE Pn In GS GS1 GS3 kw A kw A A A A SHE-/ 7,71 CA7/ 1,1 3,, 18, 3,13 SHE./, 1, CA1/ 1,8,13,8,93 31, SHE-/7 7, 13,9 3SV11 1,1,1 7,8 3,1 1,7 SHE-/11 11, 3SV1 1,1,1, 3,1, SHE3-/7,7,1 CA7/33,7,18,3,,8 SHE3-/11 1,1,1 CA7/33,7,18, 7, 7,83 SHE3-1/ 1, 3, CA7/33,7,18,9 9,8 1,3 SHE3-1/,,3 CA7/33,7,18 1, 1,,9 SHE3-/3 3, CA7/3,9,1 1,,11 18,7 SHE3-/ 7,71 CA7/ 1,1 3,, 18, 3,13 SHE3-/, 1, CA1/ 1,8,13,8,93 31, SHE3-/7 7, 13,9 3SV1 1,1,1 7,8 3,1 1,7 SHE3-/11 11, 3SV1 1,1,1, 3,1, SHE-/11 1,1,1 CA7/33,7,18, 7, 7,83 SHE-/ 1, 3, CA7/33,7,18,9 9,8 1,3 SHE-/,,3 CA7/33,7,18 1, 1,,9 SHE-1/3 3, CA7/33,7,18 1, 1,8 18,7 SHE-1/ 7,71 CA7/33,7,18, 17, 3,13 SHE-/, 1, CA7/3,9,1,8 3,1 31, SHE-/7 7, 13,9 CA1/ 1,8,13 7,8 3,93 1,7 SHE-/9 9, 1,7 3SV9 1,1,1 33, 3,1,1 SHE-/11 11, 3SV11 1,1,1, 3,1, SHE-/, 3SV1 1,1,1,,1 78, SHE-/,,3 CA7/33,7,18 1, 1,,9 SHE-/3 3, CA7/33,7,18 1, 1,8 18,7 SHE-/ 7,71 CA7/33,7,18, 17, 3,13 SHE-1/, 1, CA7/33,7,18,8,98 31, SHE-1/7 7, 13,9 CA7/33,7,18 7,8 9,98 1,7 SHE-/9 9, 1,7 CA7/ 1,1 3, 33, 3,,1 SHE-/11 11, CA1/ 1,8,13,,3, SHE-/, 3SV1 1,1,1,,1 78, SHE-/18 18, 33, 3SV11 1,1,1,8 9,1 1, SHE-/ 37,9 3SV1 1,1,1 7,8 78,1 113,7 SHE-1/ 7,71 CA7/33,7,18, 17, 3,13 SHE-1/, 1, CA7/33,7,18,8,98 31, SHE-1/7 7, 13,9 CA7/33,7,18 7,8 9,98 1,7 SHE-1/9 9, 1,7 CA7/33,7,18 33, 3,8,1 SHE-1/11 11, CA7/33,7,18,,8, SHE-/, CA7/ 1,1 3,,, 78, SHE-/18 18, 33, CA1/ 1,8,13,8 71,93 1, SHE-/ 37,9 3SV1 1,1,1 7,8 78,1 113,7 SHS-/3 3 3SV1 1,1,1 18, 11,1 1, SHS-/37 37 3SV13 1, 3, 13, 133, 19, SHE8-1/11 11, CA7/33,7,18,,8, SHE8-1/, CA7/33,7,18,,8 78, SHE8-1/18 18, 33, CA7/3,9,1,8 9,1 1, SHE8-/ 37,9 CA7/ 1,1 3, 7,8 78,8 113,7 SHS8-/3 3 CA1/ 1,8,13 18, 113,13 1, SHS8-/37 37 3SV1 1,1,1 13, 13,1 19, The current shown is the nominal current of the set. gms_shes_p_b_te 7

Booster sets GSD - GSY Series MARKET SECTORS CIVIL, INDUSTRIAL APPLICATIONS Water network supply in condominiums, offices, hotels, shopping centres, factories. Water supply to agricultural water networks (e.g. irrigation). GS.../SH SPECIFICATIONS Flow rate up to m 3 /h. Head up to 1 m. Electrical panel supply voltage: 3 x V ± 1%. Frequency Hz. Voltage for controls outside panel: Vac. Electrical panel protection class IP. Maximum service pump power: x 37 kw. Motor start-up: - Direct for powers up to kw inclusive for pump (GSD/). - Star/Delta for higher powers (GSY/ set). - Softstarter, available on request (GSSF/ set). Electric pumps with horizontal axis: - SH series (motor protection class IP). Maximum operating pressure: 1 bar. Maximum temperature of pumped liquid : +8 C. 7

TWO-PUMP BOOSTER SETS, GSD-GSY SERIES HORIZONTAL ELECTRIC PUMPS WITH NON-RETURN VAL ALVE ON DISCHARGE SIDE GS.../SH 7

TWO-PUMP BOOSTER SETS, GSD-GSY SERIES HORIZONTAL ELECTRIC PUMPS WITH NON-RETURN VAL ALVE ON DISCHARGE SIDE GSD / GSY DRW N DNA DNM A B C D E F H H1 H H3 I L SHE-/ 1 8 19 3 9 88 7 13 38 1 11 37 SHE./ 1 8 19 3 31 88 7 13 73 191 973 37 SHE-/7 1 8 19 3 31 88 7 13 73 191 973 37 SHE-/11 1 8 19 3 31 88 7 13 73 191 973 37 SHE3-/7 1 8 19 3 9 88 7 13 19 8 117 11 37 SHE3-/11 1 8 19 3 9 88 7 13 19 8 117 11 37 SHE3-1/ 1 8 19 3 9 88 7 13 1 11 11 37 SHE3-1/ 1 8 19 3 9 88 7 13 1 11 11 37 SHE3-/3 1 8 19 3 9 88 7 13 7 1 11 37 SHE3-/ 1 8 19 3 9 88 7 13 7 1 11 37 SHE3-/ 1 8 19 3 31 8 7 13 739 137 973 37 SHE3-/7 1 8 19 3 31 8 7 13 739 137 973 37 SHE3-/11 1 8 19 3 31 8 7 13 739 137 973 37 SHE-/11 1 1 19 71 37 11 88 19 1 117 9 89 SHE-/ 1 1 19 71 37 11 88 19 1 117 9 89 SHE-/ 1 1 19 71 37 11 88 19 1 117 9 89 SHE-1/3 1 1 19 71 37 11 88 1 9 13 117 9 89 SHE-1/ 1 1 19 71 37 11 88 1 9 13 117 9 89 SHE-/ 1 1 19 71 37 11 88 73 13 97 9 89 SHE-/7 1 1 19 71 37 11 88 73 13 97 9 89 SHE-/9 1 1 19 71 37 11 88 88 1 97 9 89 SHE-/11 1 1 19 71 37 11 88 88 1 97 9 89 SHE-/ 1 1 37 88 88 1 111 9 89 SHE-/ 19 71 37 118 88 1 73 13 117 9 89 SHE-/3 19 71 37 118 88 1 73 13 117 9 89 SHE-/ 19 71 37 118 88 1 73 13 117 9 89 SHE-1/ 19 71 37 118 88 78 1 97 9 89 SHE-1/7 19 71 37 118 88 78 1 97 9 89 SHE-/9 19 71 37 118 88 8 1 97 9 89 SHE-/11 19 71 37 118 88 8 1 97 9 89 SHE-/ 37 187 88 8 1 111 9 89 SHE-/18 3 8 37 7 88 3 3 88 111 9 1 SHE-/ 8 8 37 117 88 3 3 88 71 9 1 SHE-1/ 3 19 71 11 18 9 179 117 9 89 SHE-1/ 3 19 71 11 18 9 179 97 9 89 SHE-1/7 3 19 71 11 18 9 179 97 9 89 SHE-1/9 3 19 71 11 18 9 179 97 9 89 SHE-1/11 3 19 71 11 18 9 179 97 9 89 SHE-/ 3 11 1 9 19 17 111 9 89 SHE-/18 3 3 8 11 1831 9 3 3 113 17 111 9 1 SHE-/ 3 8 8 11 1881 9 3 3 113 17 71 9 1 SHS-/3 3 8 9 11 1981 9 3 3 117 189 71 9 1 SHS-/37 3 8 9 11 1981 9 3 3 117 189 71 9 1 SHE8-1/11 3 19 71 8 3 98 17 181 97 9 89 SHE8-1/ 3 8 1 98 17 181 111 9 89 SHE8-1/18 3 3 8 8 193 98 3 3 1197 18 111 9 1 SHE8-/ 3 8 8 8 198 98 3 3 1 1881 71 9 1 SHS8-/3 3 8 9 8 8 98 3 3 1 191 71 9 1 SHS8-/37 3 8 9 8 8 98 3 3 17 1931 71 9 1 Dimensions in mm. Tolerance ± 1 mm. gs_she-en_a_td GS.../SH 77

TWO-PUMP BOOSTER SETS, GSD-GSY RA SERIES HORIZONTAL ELECTRIC PUMPS WITH NON-RETURN VAL ALVE ON SUCTION SIDE GS.../SH 78

TWO-PUMP BOOSTER SETS, GSD-GSY RA SERIES HORIZONTAL ELECTRIC PUMPS WITH NON-RETURN VAL ALVE ON SUCTION SIDE GSD / GSYRA DRW N DNA DNM A B C D E F H H1 H H3 I L SHE-/ 1 8 19 3 93 7 13 33 111 11 37 SHE./ 1 8 19 3 983 7 13 98 118 973 37 SHE-/7 1 8 19 3 983 7 13 98 118 973 37 SHE-/11 1 8 19 3 983 7 13 98 118 973 37 SHE3-/7 1 8 19 3 93 7 13 19 73 11 11 37 SHE3-/11 1 8 19 3 93 7 13 19 73 11 11 37 SHE3-1/ 1 8 19 3 93 7 13 1 13 111 11 37 SHE3-1/ 1 8 19 3 93 7 13 1 13 111 11 37 SHE3-/3 1 8 19 3 93 7 13 1 119 11 37 SHE3-/ 1 8 19 3 93 7 13 1 119 11 37 SHE3-/ 1 8 19 3 981 7 13 11 973 37 SHE3-/7 1 8 19 3 981 7 13 11 973 37 SHE3-/11 1 8 19 3 981 7 13 11 973 37 SHE-/11 1 1 19 71 7 13 88 19 1 117 9 89 SHE-/ 1 1 19 71 7 13 88 19 1 117 9 89 SHE-/ 1 1 19 71 7 13 88 19 1 117 9 89 SHE-1/3 1 1 19 71 7 13 88 1 8 119 117 9 89 SHE-1/ 1 1 19 71 7 13 88 1 8 119 117 9 89 SHE-/ 1 1 19 71 77 88 33 1 97 9 89 SHE-/7 1 1 19 71 77 88 33 1 97 9 89 SHE-/9 1 1 19 71 77 88 98 13 97 9 89 SHE-/11 1 1 19 71 77 88 98 13 97 9 89 SHE-/ 1 1 77 13 88 98 13 111 9 89 SHE-/ 19 71 131 88 1 1 11 117 9 89 SHE-/3 19 71 131 88 1 1 11 117 9 89 SHE-/ 19 71 131 88 1 1 11 117 9 89 SHE-1/ 19 71 131 88 9 189 97 9 89 SHE-1/7 19 71 131 88 9 189 97 9 89 SHE-/9 19 71 131 88 89 139 97 9 89 SHE-/11 19 71 131 88 89 139 97 9 89 SHE-/ 117 88 73 13 111 9 89 SHE-/18 3 8 197 88 3 3 77 139 111 9 1 SHE-/ 8 8 177 88 3 3 77 139 71 9 1 SHE-1/ 3 19 71 8 9 9 9 117 9 89 SHE-1/ 3 19 71 8 9 9 9 97 9 89 SHE-1/7 3 19 71 8 9 9 9 97 9 89 SHE-1/9 3 19 71 8 9 9 9 97 9 89 SHE-1/11 3 19 71 8 9 9 9 97 9 89 SHE-/ 3 8 18 9 97 1 111 9 89 SHE-/18 3 3 8 8 1888 9 3 3 11 1 111 9 1 SHE-/ 3 8 8 8 1938 9 3 3 11 1 71 9 1 SHS-/3 3 8 9 8 38 9 3 3 189 71 9 1 SHS-/37 3 8 9 8 38 9 3 3 189 71 9 1 SHE8-1/11 3 19 71 78 117 98 99 1 97 9 89 SHE8-1/ 3 78 17 98 99 1 111 9 89 SHE8-1/18 3 3 8 78 98 3 3 13 19 111 9 1 SHE8-/ 3 8 8 78 98 3 3 11 17 71 9 1 SHS8-/3 3 8 9 78 98 3 3 181 17 71 9 1 SHS8-/37 3 8 9 78 98 3 3 1111 177 71 9 1 Dimensions in mm. Tolerance ± 1 mm. gsra_she-en_a_td GS.../SH 79

GS.../SH 8

Booster sets GSD1 - GSY1 Series MARKET SECTORS CIVIL, INDUSTRIAL APPLICATIONS Water network supply in condominiums, offices, hotels, shopping centres, factories. Water supply to agricultural water networks (e.g. irrigation). GS.../SH SPECIFICATIONS Flow rate up to m 3 /h. Head up to 1 m. Electrical panel supply voltage: 3 x V ± 1%. Frequency Hz. Voltage for controls outside panel: Vac. Electrical panel protection class IP. Maximum service pump power: x 37 kw. Motor start-up: - Direct for powers up to kw inclusive for pump (GSD/). - Star/Delta for higher powers (GSY/ set). - Softstarter, available on request (GSSF/ set). Electric pumps with horizontal axis: - SH series (motor protection class IP). Electric jockey pumps - SV and CA series (motor protection class IP). Maximum operating pressure: 1 bar. Maximum temperature of pumped liquid : +8C. 81

TWO-PUMP BOOSTER SETS, GSD1 SERIES HORIZONTAL ELECTRIC PUMPS WITH JOCKEY PUMP NON-RETURN VAL ALVE ON DISCHARGE SIDE GS.../SH 8

TWO-PUMP BOOSTER SETS, GSD1 SERIES HORIZONTAL ELECTRIC PUMPS WITH JOCKEY PUMP NON-RETURN VAL ALVE ON DISCHARGE SIDE GSD1 DRW N DNA DNM A B C D E F H H1 H H3 I L SHE-/ 1 8 3 9 878 19 18 38 1 973 37 99 SHE./ 1 8 3 31 898 19 18 73 191 973 37 99 SHE-/7 1 8 3 31 898 19 18 73 191 973 37 99 SHE-/11 1 8 3 31 898 19 18 73 191 973 37 99 SHE3-/7 1 8 3 9 878 19 18 19 8 117 973 37 99 SHE3-/11 1 8 3 9 878 19 18 19 8 117 973 37 99 SHE3-1/ 1 8 3 9 878 19 18 1 11 973 37 99 SHE3-1/ 1 8 3 9 878 19 18 1 11 973 37 99 SHE3-/3 1 8 3 9 878 19 18 7 1 973 37 99 SHE3-/ 1 8 3 9 878 19 18 7 1 973 37 99 SHE3-/ 1 8 3 31 89 19 18 739 137 973 37 99 SHE3-/7 1 8 3 31 89 19 18 739 137 973 37 99 SHE3-/11 1 8 3 31 89 19 18 739 137 973 37 99 SHE-/11 1 1 71 37 1 137 177 19 1 97 9 133 SHE-/ 1 1 71 37 1 137 177 19 1 97 9 133 SHE-/ 1 1 71 37 1 137 177 19 1 97 9 133 SHE-1/3 1 1 71 37 1 137 177 1 9 13 97 9 133 SHE-1/ 1 1 71 37 1 137 177 1 9 13 97 9 133 SHE-/ 1 1 71 37 117 137 177 73 13 97 9 133 SHE-/7 1 1 71 37 117 137 177 73 13 97 9 133 SHE-/9 1 1 71 37 117 137 177 88 1 71 9 133 SHE-/11 1 1 71 37 117 137 177 88 1 71 9 133 SHE-/ 1 1 37 137 177 88 1 71 9 133 SHE-/ 71 37 13 137 177 1 73 13 97 9 133 SHE-/3 71 37 13 137 177 1 73 13 97 9 133 SHE-/ 71 37 13 137 177 1 73 13 97 9 133 SHE-1/ 71 37 13 137 177 78 1 97 9 133 SHE-1/7 71 37 13 137 177 78 1 97 9 133 SHE-/9 71 37 13 137 177 8 1 71 9 133 SHE-/11 71 37 13 137 177 8 1 71 9 133 SHE-/ 37 187 137 177 8 1 71 9 133 SHE-/18 8 8 37 117 137 3 3 88 71 9 19 SHE-/ 8 8 37 117 137 3 3 88 71 9 19 SHE-1/ 3 71 11 198 11 177 179 97 9 133 SHE-1/ 3 71 11 198 11 177 179 97 9 133 SHE-1/7 3 71 11 198 11 177 179 97 9 133 SHE-1/9 3 71 11 198 11 177 179 71 9 133 SHE-1/11 3 71 11 198 11 177 179 71 9 133 SHE-/ 3 11 1 11 177 19 17 71 9 133 SHE-/18 3 8 8 11 1881 11 3 3 113 17 71 9 19 SHE-/ 3 8 8 11 1881 11 3 3 113 17 71 9 19 SHE8-1/11 3 71 8 13 17 177 17 181 71 9 133 SHE8-1/ 3 8 1 17 177 17 181 71 9 133 SHE8-1/18 3 8 8 8 198 17 3 3 1197 18 71 9 19 SHE8-/ 3 8 8 8 198 17 3 3 1 1881 71 9 19 Dimensions in mm. Tolerance ± 1 mm. gs1_she-en_a_td GS.../SH 83

TWO-PUMP BOOSTER SETS, GSD1 RA SERIES HORIZONTAL ELECTRIC PUMPS WITH JOCKEY PUMP NON-RETURN VAL ALVE ON SUCTION SIDE GS.../SH 8

TWO-PUMP BOOSTER SETS, GSD1 RA SERIES HORIZONTAL ELECTRIC PUMPS WITH JOCKEY PUMP NON-RETURN VAL ALVE ON SUCTION SIDE GSD1RA DRW N DNA DNM A B C D E F H H1 H H3 I L SHE-/ 1 8 3 113 19 18 33 111 973 37 99 SHE./ 1 8 3 133 19 18 98 118 973 37 99 SHE-/7 1 8 3 133 19 18 98 118 973 37 99 SHE-/11 1 8 3 133 19 18 98 118 973 37 99 SHE3-/7 1 8 3 113 19 18 19 73 11 973 37 99 SHE3-/11 1 8 3 113 19 18 19 73 11 973 37 99 SHE3-1/ 1 8 3 113 19 18 1 13 111 973 37 99 SHE3-1/ 1 8 3 113 19 18 1 13 111 973 37 99 SHE3-/3 1 8 3 113 19 18 1 119 973 37 99 SHE3-/ 1 8 3 113 19 18 1 119 973 37 99 SHE3-/ 1 8 3 131 19 18 11 973 37 99 SHE3-/7 1 8 3 131 19 18 11 973 37 99 SHE3-/11 1 8 3 131 19 18 11 973 37 99 SHE-/11 1 1 71 7 18 137 177 19 1 97 9 133 SHE-/ 1 1 71 7 18 137 177 19 1 97 9 133 SHE-/ 1 1 71 7 18 137 177 19 1 97 9 133 SHE-1/3 1 1 71 7 18 137 177 1 8 119 97 9 133 SHE-1/ 1 1 71 7 18 137 177 1 8 119 97 9 133 SHE-/ 1 1 71 77 13 137 177 33 1 97 9 133 SHE-/7 1 1 71 77 13 137 177 33 1 97 9 133 SHE-/9 1 1 71 77 13 137 177 98 13 71 9 133 SHE-/11 1 1 71 77 13 137 177 98 13 71 9 133 SHE-/ 1 1 77 13 137 177 98 13 71 9 133 SHE-/ 71 13 137 177 1 1 11 97 9 133 SHE-/3 71 13 137 177 1 1 11 97 9 133 SHE-/ 71 13 137 177 1 1 11 97 9 133 SHE-1/ 71 13 137 177 9 189 97 9 133 SHE-1/7 71 13 137 177 9 189 97 9 133 SHE-/9 71 13 137 177 89 139 71 9 133 SHE-/11 71 13 137 177 89 139 71 9 133 SHE-/ 117 137 177 73 13 71 9 133 SHE-/18 8 8 177 137 3 3 77 139 71 9 19 SHE-/ 8 8 177 137 3 3 77 139 71 9 19 SHE-1/ 3 71 8 11 177 9 9 97 9 133 SHE-1/ 3 71 8 11 177 9 9 97 9 133 SHE-1/7 3 71 8 11 177 9 9 97 9 133 SHE-1/9 3 71 8 11 177 9 9 71 9 133 SHE-1/11 3 71 8 11 177 9 9 71 9 133 SHE-/ 3 8 18 11 177 97 1 71 9 133 SHE-/18 3 8 8 8 1938 11 3 3 11 1 71 9 19 SHE-/ 3 8 8 8 1938 11 3 3 11 1 71 9 19 SHE8-1/11 3 71 78 17 17 177 99 1 71 9 133 SHE8-1/ 3 78 17 17 177 99 1 71 9 133 SHE8-1/18 3 8 8 78 17 3 3 13 19 71 9 19 SHE8-/ 3 8 8 78 17 3 3 11 17 71 9 19 Dimensions in mm. Tolerance ± 1 mm. gs1ra_she-en_a_td GS.../SH 8

TWO-PUMP BOOSTER SETS, GSY1 SERIES HORIZONTAL ELECTRIC PUMPS WITH JOCKEY PUMP NON-RETURN VAL ALVE ON DISCHARGE SIDE GS.../SH GSY1 DNA DNM B C D E F H H1 H I L X Y Z SHS-/3 9 11 19 11 3 3 117 189 9 19 3 SHS-/37 9 11 19 11 3 3 117 189 9 19 3 SHS8-/3 9 8 181 17 3 3 1 191 9 19 3 SHS8-/37 9 8 181 17 3 3 17 1931 9 19 3 Dimensions in mm. Tolerance ± 1 mm. gs1_she8-en_a_td 8

TWO-PUMP BOOSTER SETS, GSY1 RA SERIES HORIZONTAL ELECTRIC PUMPS WITH JOCKEY PUMP NON-RETURN VAL ALVE ON SUCTION SIDE GS.../SH GSY1RA DNA DNM B C D E F H H1 H I L X Y Z SHS-/3 9 8 173 11 3 3 189 9 19 3 SHS-/37 9 8 173 11 3 3 189 9 19 3 SHS8-/3 9 78 18 17 3 3 181 17 9 19 3 SHS8-/37 9 78 18 17 3 3 1111 177 9 19 3 Dimensions in mm. Tolerance ± 1 mm. gs1ra_she8-en_a_td 87

GS.../SH 88

Booster sets GSD3 - GSY3 Series MARKET SECTORS CIVIL, INDUSTRIAL APPLICATIONS Water network supply in condominiums, offices, hotels, shopping centres, factories. Water supply to agricultural water networks (e.g. irrigation). GS.../SH SPECIFICATIONS Flow rate up to m 3 /h. Head up to 1 m. Electrical panel supply voltage: 3 x V ± 1%. Frequency Hz. Voltage for controls outside panel: Vac. Electrical panel protection class IP. Maximum service pump power: 3 x 37 kw. Motor start-up: - Direct for powers up to kw inclusive for pump (GSD/). - Star/Delta for higher powers (GSY/ set). - Softstarter, available on request (GSSF/ set). Electric pumps with horizontal axis: - SH series (motor protection class IP). Maximum operating pressure: 1 bar. Maximum temperature of pumped liquid : +8 C. 89

THREE-PUMP BOOSTER SETS, GSD3 SERIES HORIZONTAL ELECTRIC PUMPS WITH NON-RETURN VAL ALVE ON DISCHARGE SIDE GS.../SH 9

THREE-PUMP BOOSTER SETS, GSD3 SERIES HORIZONTAL ELECTRIC PUMPS WITH NON-RETURN VAL ALVE ON DISCHARGE SIDE GSD3 DRW N DNA DNM A B C D E F H H1 H H3 I L SHE-/ 1 8 3 3 9 113 18 139 973 37 99 SHE./ 1 8 3 3 97 113 18 71 13 973 37 99 SHE-/7 1 8 3 3 97 113 18 71 13 973 37 99 SHE-/11 1 8 3 3 97 113 18 71 13 973 37 99 SHE3-/7 1 8 3 3 9 113 18 19 93 1187 973 37 99 SHE3-/11 1 8 3 3 9 113 18 19 93 1187 973 37 99 SHE3-1/ 1 8 3 3 9 113 18 1 33 17 973 37 99 SHE3-1/ 1 8 3 3 9 113 18 1 33 17 973 37 99 SHE3-/3 1 8 3 3 9 113 18 81 17 973 37 99 SHE3-/ 1 8 3 3 9 113 18 81 17 973 37 99 SHE3-/ 1 8 3 3 97 113 18 7 13 973 37 99 SHE3-/7 1 8 3 3 97 113 18 7 13 973 37 99 SHE3-/11 1 8 3 3 97 113 18 7 13 973 37 99 SHE-/11 71 3 118 137 177 19 8 188 97 9 133 SHE-/ 71 3 118 137 177 19 8 188 97 9 133 SHE-/ 71 3 118 137 177 19 8 188 97 9 133 SHE-1/3 71 3 118 137 177 1 78 138 97 9 133 SHE-1/ 71 3 118 137 177 1 78 138 97 9 133 SHE-/ 71 3 1 137 177 7 137 97 9 133 SHE-/7 71 3 1 137 177 7 137 97 9 133 SHE-/9 71 3 1 137 177 81 11 71 9 133 SHE-/11 71 3 1 137 177 81 11 71 9 133 SHE-/ 3 3 137 177 81 11 71 9 133 SHE-/ 71 187 137 177 1 7 138 97 9 133 SHE-/3 71 187 137 177 1 7 138 97 9 133 SHE-/ 71 187 137 177 1 7 138 97 9 133 SHE-1/ 71 187 137 177 79 18 97 9 133 SHE-1/7 71 187 137 177 79 18 97 9 133 SHE-/9 71 187 137 177 81 18 71 9 133 SHE-/11 71 187 137 177 81 18 71 9 133 SHE-/ 13 137 177 89 193 71 9 133 SHE-/18 8 8 17 137 3 3 899 33 71 9 19 SHE-/ 8 8 17 137 3 3 899 33 71 9 19 SHE-1/ 3 71 38 7 17 177 171 173 97 9 133 SHE-1/ 3 71 38 7 17 177 171 173 97 9 133 SHE-1/7 3 71 38 7 17 177 171 173 97 9 133 SHE-1/9 3 71 38 7 17 177 171 173 71 9 133 SHE-1/11 3 71 38 7 17 177 171 173 71 9 133 SHE-/ 3 38 11 17 177 111 177 71 9 133 SHE-/18 3 8 8 38 19 17 3 3 1 18 71 9 19 SHE-/ 3 8 8 38 19 17 3 3 1 18 71 9 19 SHE8-1/11 3 3 71 79 1 17 177 118 187 71 9 133 SHE8-1/ 3 3 79 179 17 177 118 187 71 9 133 SHE8-1/18 3 3 8 8 79 39 17 3 3 1 191 71 9 19 SHE8-/ 3 3 8 8 79 39 17 3 3 19 193 71 9 19 Dimensions in mm. Tolerance ± 1 mm. gs3_she-en_a_td GS.../SH 91

THREE-PUMP BOOSTER SETS, GSD3 RA SERIES HORIZONTAL ELECTRIC PUMPS WITH NON-RETURN VAL ALVE ON SUCTION SIDE GS.../SH 9

THREE-PUMP BOOSTER SETS, GSD3 RA SERIES HORIZONTAL ELECTRIC PUMPS WITH NON-RETURN VAL ALVE ON SUCTION SIDE GSD3RA DRW N DNA DNM A B C D E F H H1 H H3 I L SHE-/ 1 8 3 37 191 113 18 113 973 37 99 SHE./ 1 8 3 7 1111 113 18 1199 973 37 99 SHE-/7 1 8 3 7 1111 113 18 1199 973 37 99 SHE-/11 1 8 3 7 1111 113 18 1199 973 37 99 SHE3-/7 1 8 3 37 191 113 18 19 8 17 973 37 99 SHE3-/11 1 8 3 37 191 113 18 19 8 17 973 37 99 SHE3-1/ 1 8 3 37 191 113 18 1 111 973 37 99 SHE3-1/ 1 8 3 37 191 113 18 1 111 973 37 99 SHE3-/3 1 8 3 37 191 113 18 8 11 973 37 99 SHE3-/ 1 8 3 37 191 113 18 8 11 973 37 99 SHE3-/ 1 8 3 7 119 113 18 33 17 973 37 99 SHE3-/7 1 8 3 7 119 113 18 33 17 973 37 99 SHE3-/11 1 8 3 7 119 113 18 33 17 973 37 99 SHE-/11 71 7 131 137 177 19 8 1178 97 9 133 SHE-/ 71 7 131 137 177 19 8 1178 97 9 133 SHE-/ 71 7 131 137 177 19 8 1178 97 9 133 SHE-1/3 71 7 131 137 177 1 98 118 97 9 133 SHE-1/ 71 7 131 137 177 1 98 118 97 9 133 SHE-/ 71 9 133 137 177 1 97 9 133 SHE-/7 71 9 133 137 177 1 97 9 133 SHE-/9 71 9 133 137 177 711 1331 71 9 133 SHE-/11 71 9 133 137 177 711 1331 71 9 133 SHE-/ 9 1383 137 177 711 1331 71 9 133 SHE-/ 71 3 117 137 177 1 3 19 97 9 133 SHE-/3 71 3 117 137 177 1 3 19 97 9 133 SHE-/ 71 3 117 137 177 1 3 19 97 9 133 SHE-1/ 71 3 117 137 177 83 1317 97 9 133 SHE-1/7 71 3 117 137 177 83 1317 97 9 133 SHE-/9 71 3 117 137 177 73 1337 71 9 133 SHE-/11 71 3 117 137 177 73 1337 71 9 133 SHE-/ 3 17 137 177 78 138 71 9 133 SHE-/18 8 8 3 18 137 3 3 788 1 71 9 19 SHE-/ 8 8 3 18 137 3 3 788 1 71 9 19 SHE-1/ 3 71 9 11 17 177 91 11 97 9 133 SHE-1/ 3 71 9 11 17 177 91 11 97 9 133 SHE-1/7 3 71 9 11 17 177 91 11 97 9 133 SHE-1/9 3 71 9 11 17 177 91 11 71 9 133 SHE-1/11 3 71 9 11 17 177 91 11 71 9 133 SHE-/ 3 9 17 17 177 99 1 71 9 133 SHE-/18 3 8 8 9 1997 17 3 3 13 19 71 9 19 SHE-/ 3 8 8 9 1997 17 3 3 13 19 71 9 19 SHE8-1/11 3 3 71 773 17 17 177 13 179 71 9 133 SHE8-1/ 3 3 773 1773 17 177 13 179 71 9 133 SHE8-1/18 3 3 8 8 773 13 17 3 3 13 179 71 9 19 SHE8-/ 3 3 8 8 773 13 17 3 3 188 177 71 9 19 Dimensions in mm. Tolerance ± 1 mm. gs3ra_she-en_a_td GS.../SH 93

THREE-PUMP BOOSTER SETS, GSY3 SERIES HORIZONTAL ELECTRIC PUMPS WITH NON-RETURN VAL ALVE ON DISCHARGE SIDE GS.../SH GSY3 DNA DNM B C D E F H H1 H I L X Y Z SHS-/3 9 38 17 17 3 3 11 18 9 19 3 SHS-/37 9 38 17 17 3 3 11 18 9 19 3 SHS8-/3 3 9 79 18 17 3 3 19 19 9 19 3 SHS8-/37 3 9 79 18 17 3 3 199 198 9 19 3 Dimensions in mm. Tolerance ± 1 mm. gs3_she8-en_a_td 9

THREE-PUMP BOOSTER SETS, GSY3 RA SERIES HORIZONTAL ELECTRIC PUMPS WITH NON-RETURN VAL ALVE ON SUCTION SIDE GS.../SH GSY3RA DNA DNM B C D E F H H1 H I L X Y Z SHS-/3 9 9 181 17 3 3 181 17 9 19 3 SHS-/37 9 9 181 17 3 3 181 17 9 19 3 SHS8-/3 3 9 773 1918 17 3 3 118 179 9 19 3 SHS8-/37 3 9 773 1918 17 3 3 1138 18 9 19 3 Dimensions in mm. Tolerance ± 1 mm. gs3ra_she8-en_a_td 9

BOOSTER SETS, GS.../SH SERIES OPERATING CHARACTERISTICS S AT Hz (JOCKEY PUMP) 3SV..3SV1 9 [rpm] ISO 99 - Annex A 1 Q [Imp gpm] 1 Q [US gpm] H [m] 18 H [ft] 1 1 1 19 1 1 1 8,1 1 1 1 13 11 9 8 7 3 3 1 7 GS.../SH P p [kw],8 kw/stage, 3 1 1 3 Q [m 3 /h] NPSH [m] η 1 3 7 8 Q [l/min] η [%] NPSH [ft] 798_C_CH The performance curves do not take into account flow resistance in the valves and piping. The curves show performance with one pump running. These performances are valid for liquids with density ρ = 1. kg/dm³ and kinematic viscosity ν = 1 mm²/s. 9

BOOSTER SETS, GS.../SH SERIES OPERATING CHARACTERISTICS S AT Hz (SERVICE PUMP) SH -/ ~ 9 [rpm] ISO 99 - Annex A SH -/ ~ 9 [rpm] ISO 99 - Annex A 1 3 Q [Imp gpm] 1 Q [Imp gpm] H [m] 1 3 Q [US gpm] H [ft] 1 3 Q [US gpm] H [m] H [ft] 18 3 1 1 1 P P 3 P 1 3 1 P P 3 P 1 1 NPSH [m] 8 NPSH [ft] NPSH [m] 3 8 1 NPSH [ft] 1 8 Q [m1 3 /h] 8 1 1 1 Q 1 [l/min] 77_A_CH 1 Q [m8 3 /h] 8 1 1 Q [l/min] 77_A_CH GS.../SH SH -/7 ~ 9 [rpm] ISO 99 - Annex A SH -/11 ~ 9 [rpm] ISO 99 - Annex A 1 3 Q [Imp gpm] 1 3 Q [Imp gpm] 1 3 Q [US gpm] 8 H [m] H [ft] H [m] 1 3 Q [US gpm] 9 H [ft] 8 7 8 7 18 18 1 P P 3 P 1 1 P P 3 P 1 1 1 NPSH [m] 8 NPSH [ft] NPSH [m] 8 NPSH [ft] 1 1 8 Q [m1 3 /h] 8 1 1 1 1 Q [l/min] 777_A_CH 8 Q [m1 3 /h] 8 1 1 1 1 Q [l/min] 778_A_CH The performance curves do not take into account flow resistance in the valves and piping. The curves show the performance with one, two and three pumps running. These performances are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm /s. The declared NPSH values are laboratory values: for practical use we recommend increasing these values by. m. 97

BOOSTER SETS, GS.../SH SERIES OPERATING CHARACTERISTICS S AT Hz (SERVICE PUMP) SH 3-/7 ~ 9 [rpm] ISO 99 - Annex A SH 3-/11 ~ 9 [rpm] ISO 99 - Annex A 1 Q [Imp gpm] 1 Q [Imp gpm] H [m] 1 3 Q [US gpm] H [ft] H [m] 1 3 Q [US gpm] 3 H [ft] 8 1 3 1 P P 3 P 1 1 1 P P 3 P NPSH [m] 1 NPSH [ft] NPSH [m] 1 NPSH [ft] 8 8 GS.../SH Q [m8 3 /h] 8 1 1 Q [l/min] 779_A_CH Q [m8 3 /h] 8 1 1 Q [l/min] 77_A_CH SH 3-1/ ~ 9 [rpm] ISO 99 - Annex A SH 3-1/ ~ 9 [rpm] ISO 99 - Annex A 1 Q [Imp gpm] 1 3 Q [Imp gpm] 1 3 Q [US gpm] 3 H [m] H [ft] 8 1 3 Q [US gpm] H [m] H [ft] 3 1 3 1 8 1 P P 3 P 1 1 P P 3 P 1 NPSH [m] 1 1 NPSH [ft] NPSH [m] 1 1 NPSH [ft] 8 8 Q [m8 3 /h] 8 1 1 Q [l/min] 771_A_CH 8 Q [m1 3 /h] 8 1 1 1 1 Q [l/min] 77_A_CH The performance curves do not take into account flow resistance in the valves and piping. The curves show the performance with one, two and three pumps running. These performances are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm /s. The declared NPSH values are laboratory values: for practical use we recommend increasing these values by. m. 98

BOOSTER SETS, GS.../SH SERIES OPERATING CHARACTERISTICS S AT Hz (SERVICE PUMP) SH 3-/3 ~ 9 [rpm] ISO 99 - Annex A SH 3-/ ~ 9 [rpm] ISO 99 - Annex A 1 Q [Imp gpm] 1 3 Q [Imp gpm] 1 3 Q [US gpm] 1 H [m] H [ft] 1 H [m] 1 3 Q [US gpm] H [ft] 18 1 1 1 3 1 1 8 1 P P 3 P 3 1 P P 3 P 1 8 NPSH [m] 1 8 NPSH [ft] NPSH [m] 8 NPSH [ft] 1 1 8 Q [m8 3 /h] 8 1 1 Q [l/min] 773_A_CH 1 1 8 8 Q [m1 3 /h] 8 1 1 1 1 Q [l/min] 77_A_CH GS.../SH SH 3-/ ~ 9 [rpm] ISO 99 - Annex A SH 3-/7 ~ 9 [rpm] ISO 99 - Annex A 1 Q [Imp gpm] 1 3 Q [Imp gpm] 1 3 Q [US gpm] H [m] H [ft] 1 3 Q [US gpm] 8 H [m] H [ft] 7 18 1 18 1 P P 3 P 1 1 P P 3 P 1 1 1 NPSH [m] 3 1 8 3 NPSH [ft] NPSH [m] 8 NPSH [ft] 1 1 Q [m8 3 /h] 8 1 1 Q [l/min] 77_A_CH 8 Q [m1 3 /h] 8 1 1 1 1 Q [l/min] 77_A_CH The performance curves do not take into account flow resistance in the valves and piping. The curves show the performance with one, two and three pumps running. These performances are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm /s. The declared NPSH values are laboratory values: for practical use we recommend increasing these values by. m. 99

BOOSTER SETS, GS.../SH SERIES OPERATING CHARACTERISTICS S AT Hz (SERVICE PUMP) SH 3-/11 ~ 9 [rpm] ISO 99 - Annex A SH -/11 ~ 9 [rpm] ISO 99 - Annex A 1 3 Q [Imp gpm] 1 3 Q [Imp gpm] 1 3 Q [US gpm] 9 H [m] H [ft] 8 8 H [m] 1 3 Q [US gpm] 1 1 1 H [ft] 7 1 3 8 1 P P 3 P 18 1 P P 3 P NPSH [m] 8 NPSH [ft] NPSH [m] 3 1 NPSH [ft] GS.../SH 1 8 Q [m1 3 /h] 8 1 1 1 1 Q [l/min] 777_A_CH 1 8 1 1 Q [m1 3 /h] 1 Q [l/min] 778_A_CH SH -/ ~ 9 [rpm] ISO 99 - Annex A SH -/ ~ 9 [rpm] ISO 99 - Annex A 1 3 Q [Imp gpm] 1 3 Q [Imp gpm] H [m] 1 3 Q [US gpm] 18 H [ft] H [m] Q [US gpm] 8 9 8 H [ft] 1 7 1 1 18 1 1 3 1 8 1 P P 3 P 1 1 P P 3 P 1 NPSH [m] 3 1 NPSH [ft] NPSH [m] NPSH [ft] 1 1 8 1 1 Q [m1 3 /h] 1 Q [l/min] 779_A_CH 8 1 1 1 Q [m1 3 /h] 1 Q [l/min] 777_A_CH The performance curves do not take into account flow resistance in the valves and piping. The curves show the performance with one, two and three pumps running. These performances are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm /s. The declared NPSH values are laboratory values: for practical use we recommend increasing these values by. m. 1

BOOSTER SETS, GS.../SH SERIES OPERATING CHARACTERISTICS S AT Hz (SERVICE PUMP) SH -1/3 ~ 9 [rpm] ISO 99 - Annex A SH -1/ ~ 9 [rpm] ISO 99 - Annex A 1 3 Q [Imp gpm] 1 3 Q [Imp gpm] Q [US gpm] 3 Q [US gpm] H [m] H [ft] H [m] H [ft] 3 1 3 1 8 3 1 8 1 P P 3 P 1 P P 3 P NPSH [m] 1 NPSH [ft] NPSH [m] NPSH [ft] 1 1 8 1 1 1 Q [m1 3 /h] 1 Q [l/min] 7771_A_CH 8 1 1 1 Q [m1 3 /h] 1 Q [l/min] 777_A_CH GS.../SH SH -/ ~ 9 [rpm] ISO 99 - Annex A SH -/7 ~ 9 [rpm] ISO 99 - Annex A 1 3 Q [Imp gpm] Q [US gpm] 18 1 3 Q [Imp gpm] Q [US gpm] H [m] H [ft] H [m] H [ft] 1 18 1 1 3 1 1 3 1 1 1 P P 3 P 8 3 1 P P 3 P NPSH [m] 1 NPSH [ft] NPSH [m] 3 8 1 NPSH [ft] 1 8 1 1 1 Q [m1 3 /h] 1 Q [l/min] 7773_A_CH 8 1 1 1 Q [m1 3 /h] 1 Q [l/min] 777_A_CH The performance curves do not take into account flow resistance in the valves and piping. The curves show the performance with one, two and three pumps running. These performances are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm /s. The declared NPSH values are laboratory values: for practical use we recommend increasing these values by. m. 11

BOOSTER SETS, GS.../SH SERIES OPERATING CHARACTERISTICS S AT Hz (SERVICE PUMP) SH -/9 ~ 9 [rpm] ISO 99 - Annex A SH -/11 ~ 9 [rpm] ISO 99 - Annex A 1 3 Q [Imp gpm] 1 3 Q [Imp gpm] H [m] 1 3 Q [US gpm] 7 H [ft] Q [US gpm] 8 H [m] H [ft] 7 7 18 1 18 1 P P 3 P 1 1 P P 3 P 1 NPSH [m] 8 NPSH [ft] NPSH [m] 1 NPSH [ft] GS.../SH 1 8 1 1 Q [m1 3 /h] 1 Q [l/min] 777_A_CH 8 1 1 1 Q [m1 3 /h] 1 Q [l/min] 777_A_CH SH -/ ~ 9 [rpm] ISO 99 - Annex A SH -/ ~ 9 [rpm] ISO 99 - Annex A 1 3 Q [Imp gpm] 1 3 7 8 Q [Imp 9gpm] 9 Q [US gpm] 8 Q 1 [US gpm] H [m] H [ft] 8 H [m] 18 H [ft] 8 1 1 7 1 1 3 8 1 P P 3 P 18 1 P P 3 P NPSH [m] NPSH [ft] NPSH [m] NPSH [ft] 1 1 8 1 1 1 1 Q [m18 3 /h] 1 Q [l/min] 7777_A_CH 1 Q [m 3 /h] 1 3 Q [l/min] 7778_A_CH The performance curves do not take into account flow resistance in the valves and piping. The curves show the performance with one, two and three pumps running. These performances are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm /s. The declared NPSH values are laboratory values: for practical use we recommend increasing these values by. m. 1

BOOSTER SETS, GS.../SH SERIES OPERATING CHARACTERISTICS S AT Hz (SERVICE PUMP) SH -/3 ~ 9 [rpm] ISO 99 - Annex A SH -/ ~ 9 [rpm] ISO 99 - Annex A 1 3 7 8 Q [Imp 9gpm] 1 3 7 8 9 Q 1 [Imp gpm] H [m] 8 Q 1 [US gpm] 8 H [ft] H [m] 8 1 Q 1 [US gpm] 3 H [ft] 7 8 1 1 P P 3 P 3 NPSH [m] 1 1 Q [m 3 /h] 1 3 Q [l/min] NPSH [ft] 7779_A_CH NPSH [m] 1 P P 3 P 1 8 1 1 Q [m3 3 /h] 1 3 Q [l/min] NPSH [ft] 778_A_CH GS.../SH SH -1/ ~ 9 [rpm] ISO 99 - Annex A SH -1/7 ~ 9 [rpm] ISO 99 - Annex A 1 3 7 8 9 1 Q [Imp gpm] 1 3 7 8 9 1 Q [Imp gpm] 8 1 Q 1 [US gpm] 8 1 Q 1 [US gpm] H [ft] H [m] H [ft] H [m] 1 3 8 1 3 3 3 1 8 1 P P 3 P 1 P P 3 P NPSH [m] 1 8 NPSH [ft] NPSH [m] 8 NPSH [ft] 1 1 1 Q [m3 3 /h] 1 3 Q [l/min] 7781_A_CH 1 Q [m3 3 /h] 1 3 Q [l/min] 778_A_CH The performance curves do not take into account flow resistance in the valves and piping. The curves show the performance with one, two and three pumps running. These performances are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm /s. The declared NPSH values are laboratory values: for practical use we recommend increasing these values by. m. 13

BOOSTER SETS, GS.../SH SERIES OPERATING CHARACTERISTICS S AT Hz (SERVICE PUMP) SH -/9 ~ 9 [rpm] ISO 99 - Annex A SH -/11 ~ 9 [rpm] ISO 99 - Annex A 1 3 7 8 9 1 Q [Imp gpm] 1 3 7 8 9 1 Q [Imp gpm] H [m] 8 1 Q 1 [US gpm] H [ft] 18 H [m] 8 1 Q 1 [US gpm] 7 H [ft] 1 1 18 1 1 3 1 1 8 1 1 P P 3 P 3 1 NPSH [m] 1 8 NPSH [ft] NPSH [m] 8 1 P P 3 P 8 NPSH [ft] GS.../SH 1 1 Q [m3 3 /h] 1 3 Q [l/min] 7783_A_CH 1 1 Q [m3 3 /h] 1 3 Q [l/min] 778_A_CH SH -/ ~ 9 [rpm] ISO 99 - Annex A SH -/18 ~ 9 [rpm] ISO 99 - Annex A 1 3 7 8 9 1 Q [Imp gpm] 1 3 7 8 9 1 Q [Imp gpm] 8 1 Q 1 [US gpm] 8 8 1 Q 1 [US gpm] 9 H [ft] H [m] H [ft] H [m] 8 7 8 7 18 18 1 1 P P 3 P 1 1 P P 3 P 1 1 NPSH [m] NPSH [ft] NPSH [m] NPSH [ft] 1 1 1 Q [m 3 /h] 1 3 Q [l/min] 778_A_CH 1 Q [m3 3 /h] 1 3 Q [l/min] 778_A_CH The performance curves do not take into account flow resistance in the valves and piping. The curves show the performance with one, two and three pumps running. These performances are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm /s. The declared NPSH values are laboratory values: for practical use we recommend increasing these values by. m. 1

BOOSTER SETS, GS.../SH SERIES OPERATING CHARACTERISTICS S AT Hz (SERVICE PUMP) SH -/ ~ 9 [rpm] ISO 99 - Annex A SH -1/ ~ 9 [rpm] ISO 99 - Annex A 1 3 7 8 9 1 Q [Imp gpm] 8 1 Q 1 [Imp gpm] H [m] 8 1 Q 1 [US gpm] 1 3 H [ft] H [m] 8 1 1 Q 1 [US gpm] 8 H [ft] 9 3 7 8 8 7 1 3 NPSH [m] 1 P P 3 P 18 1 1 Q [m3 3 /h] 1 3 Q [l/min] NPSH [ft] 7787_A_CH NPSH [m] 8 1 P P 3 P 1 3 Q [m3 3 /h] 1 3 Q [l/min] 1 NPSH [ft] 7788_A_CH GS.../SH SH -1/ ~ 9 [rpm] ISO 99 - Annex A SH -1/7 ~ 9 [rpm] ISO 99 - Annex A 8 1 1 Q [Imp 1 gpm] 8 1 1 Q [Imp 1 gpm] 8 1 1 1 Q 1 [US gpm] 3 8 1 1 1 Q 1 [US gpm] 3 H [m] H [ft] H [m] 9 H [ft] 8 8 7 1 1 P P 3 P 1 P P 3 P NPSH [m] 8 NPSH [ft] NPSH [m] 1 1 3 NPSH [ft] 1 1 1 3 Q [m 3 /h] 1 3 Q [l/min] 7789_A_CH 1 3 Q [m 3 /h] 1 3 Q [l/min] 779_A_CH The performance curves do not take into account flow resistance in the valves and piping. The curves show the performance with one, two and three pumps running. These performances are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm /s. The declared NPSH values are laboratory values: for practical use we recommend increasing these values by. m.

BOOSTER SETS, GS.../SH SERIES OPERATING CHARACTERISTICS S AT Hz (SERVICE PUMP) SH -1/9 ~ 9 [rpm] ISO 99 - Annex A SH -1/11 ~ 9 [rpm] ISO 99 - Annex A 8 1 1 Q [Imp 1 gpm] 8 1 1 Q [Imp 1 gpm] 8 1 1 1 Q 1 [US gpm] 13 8 1 1 1 Q 1 [US gpm] H [m] 3 1 H [ft] H [m] 1 13 H [ft] 11 1 3 3 1 11 9 3 1 8 9 8 1 P P 3 P 7 1 P P 3 P 7 NPSH [m] NPSH [ft] NPSH [m] NPSH [ft] 1 1 GS.../SH 1 3 Q [m 3 /h] 1 3 Q [l/min] 7791_A_CH 1 3 Q [m 3 /h] 1 3 Q [l/min] 779_A_CH SH -/ ~ 9 [rpm] ISO 99 - Annex A SH -/18 ~ 9 [rpm] ISO 99 - Annex A 8 1 1 Q [Imp 1 gpm] 8 1 1 Q [Imp 1 gpm] 8 1 1 1 Q 1 [US gpm] 18 8 1 1 1 Q 1 [US gpm] 7 H [m] 1 H [ft] H [m] H [ft] 1 18 1 1 3 1 3 1 1 1 P P 3 P 1 P P 3 P NPSH [m] 8 NPSH [ft] NPSH [m] 3 1 1 NPSH [ft] 1 1 3 Q [m 3 /h] 1 3 Q [l/min] 7793_A_CH 1 3 Q [m 3 /h] 1 3 Q [l/min] 779_A_CH The performance curves do not take into account flow resistance in the valves and piping. The curves show the performance with one, two and three pumps running. These performances are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm /s. The declared NPSH values are laboratory values: for practical use we recommend increasing these values by. m. 1

BOOSTER SETS, GS.../SH SERIES OPERATING CHARACTERISTICS S AT Hz (SERVICE PUMP) SH -/ ~ 9 [rpm] ISO 99 - Annex A SH -/3 ~ 9 [rpm] ISO 99 - Annex A 8 1 1 Q [Imp 1 gpm] 8 1 1 Q [Imp 1 gpm] 8 1 1 1 Q 1 [US gpm] 8 1 1 1 Q 1 [US gpm] 9 H [ft] 7 H [ft] H [m] 8 H [m] 8 18 7 1 1 P P 3 P 1 1 P P 3 P 1 18 NPSH [m] 3 8 1 NPSH [ft] NPSH [m] 8 NPSH [ft] 1 1 3 Q [m 3 /h] 1 3 Q [l/min] 779_A_CH 1 1 3 Q [m 3 /h] 1 3 Q [l/min] 779_A_CH GS.../SH SH -/37 ~ 9 [rpm] ISO 99 - Annex A SH 8-1/11 ~ 9 [rpm] ISO 99 - Annex A 8 1 1 1 1 Q [Imp 18gpm] 1 Q [US gpm] 1 1 Q [Imp gpm] 1 Q [US gpm] 3 H [m] 3 H [ft] H [m] 1 H [ft] 9 3 3 1 8 8 8 7 1 P P 3 P 1 1 P P 3 P NPSH [m] 1 3 NPSH [ft] NPSH [m] 8 NPSH [ft] 1 1 1 3 Q [m 3 /h] 1 3 7 Q 8 [l/min] 7797_A_CH 1 3 Q [m7 3 /h] 8 1 Q [l/min] 7798_A_CH The performance curves do not take into account flow resistance in the valves and piping. The curves show the performance with one, two and three pumps running. These performances are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm /s. The declared NPSH values are laboratory values: for practical use we recommend increasing these values by. m. 17

BOOSTER SETS, GS.../SH SERIES OPERATING CHARACTERISTICS S AT Hz (SERVICE PUMP) SH 8-1/ ~ 9 [rpm] ISO 99 - Annex A SH 8-1/18 ~ 9 [rpm] ISO 99 - Annex A 1 Q [Imp gpm] 1 Q [Imp gpm] 1 Q [US gpm] 3 1 1 Q [US gpm] 3 1 H [m] H [ft] H [m] H [ft] 1 1 1 1 3 1 3 1 8 8 1 P P 3 P 1 P P 3 P NPSH [m] 1 8 NPSH [ft] NPSH [m] 1 8 NPSH [ft] GS.../SH 1 1 3 Q [m7 3 /h] 8 1 Q [l/min] 7799_A_CH 1 1 3 Q [m7 3 /h] 8 1 Q [l/min] 78_A_CH SH 8-/ ~ 9 [rpm] ISO 99 - Annex A SH 8-/3 ~ 9 [rpm] ISO 99 - Annex A 1 Q [Imp gpm] 1 Q [Imp gpm] 1 Q [US gpm] 3 1 3 7 Q [US gpm] H [m] 18 H [ft] H [m] H [ft] 1 18 1 1 1 1 3 1 1 P P 3 P 8 1 P P 3 P 1 NPSH [m] NPSH [ft] NPSH [m] 3 1 NPSH [ft] 1 1 1 3 Q [m7 3 /h] 8 1 Q [l/min] 781_A_CH Q [m8 3 /h] 8 1 1 Q [l/min] 78_A_CH The performance curves do not take into account flow resistance in the valves and piping. The curves show the performance with one, two and three pumps running. These performances are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm /s. The declared NPSH values are laboratory values: for practical use we recommend increasing these values by. m. 18

BOOSTER SETS, GS.../SH SERIES OPERATING CHARACTERISTICS S AT Hz (SERVICE PUMP) SH 8-/37 ~ 9 [rpm] ISO 99 - Annex A 1 Q [Imp gpm] H [m] 1 3 8 Q [US gpm] H [ft] 7 1 1 P P 3 P 1 NPSH [m] 3 8 NPSH [ft] 1 Q [m8 3 /h] 8 1 1 Q [l/min] 783_A_CH GS.../SH The performance curves do not take into account flow resistance in the valves and piping. The curves show the performance with one, two and three pumps running. These performances are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm /s. The declared NPSH values are laboratory values: for practical use we recommend increasing these values by. m. 19

BOOSTER SETS, GS.../SH SERIES Hc PRESSURE SURE DROP CURVE SH SUCTION SIDE SH DISCHARGE SIDE 8 1 Q [Imp gpm] 8 1 Q [Imp gpm] 8 1 1 Q [US gpm],1 Hc [m],8, A Hc [ft],3 Hc [m] 8 1 1 Q [US gpm] 1 8 A 3 Hc [ft],,,,,1 1,,,,,1 Hc [m] 3 Col 1 vs Col Col vs Col 1 Col vs Col 1 1 1 Hc [ft] Hc [m],8 Col 1 vs Col Col vs Col 1 Col vs Col 1,3, Hc [ft] B 8,,, B, GS.../SH 1 1 Q [m 3 3 /h] 1 3 Q [l/min] 7717_A_CH,1,,,, 1 Q [m 3 3 /h] 1 3 Q [l/min] 7711_A_CH SH 3 SUCTION SIDE SH 3 DISCHARGE SIDE 8 1 Q [Imp gpm] 8 1 1 Q [US gpm],1 Hc [ft] 8 1 Q [Imp gpm] 8 1 1 Q [US gpm] 1 Hc [m],8 A,3, Hc [m] 8 A 3 Hc [ft],,,,,1 1,,,,,1 Hc [m] 3 Col 1 vs Col Col vs Col 1 Col vs Col 1 B 1 1 8 Hc [ft] Hc [m],8, Col 1 vs Col Col vs Col 1 Col vs Col 1,3,, Hc [ft], B, 1,,1, 1 Q [m 3 3 /h] 1 3 Q [l/min] 7718_A_CH,, 1 Q [m 3 3 /h] 1 3 Q [l/min] 771_A_CH The declared curves are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. Hc (A): Pressure drop curve with check valve installed on the delivery side of the pump. Hc (B): Pressure drop curve with check valve installed on the suction side of the pump. The pressure drops do not consider the pressure drops distributed in the manifold. 11

BOOSTER SETS, GS.../SH SERIES Hc PRESSURE SURE DROP CURVE SH SUCTION SIDE SH DISCHARGE SIDE 1 Q [Imp gpm] 1 Q [Imp gpm] 1 Q [US gpm],1 Hc [m],8 A, Hc [ft],3 Hc [m] 1 Q [US gpm] Hc [ft],,,, 1 A 3,,1, 1, Hc [m] 3 1 Col 1 vs Col Col vs Col 1 Col vs Col 1 1 3 Q [m 3 /h] 8 Q [l/min] 1 B, 1 1 1 1 8 Hc [ft] 7719_A_CH,1 Hc [m],8,,, Col 1 vs Col Col vs Col 1 Col vs Col 1,, 1 3 Q [m 3 /h] 8 Q [l/min] 1 B,3,,,,1, Hc [ft] 7713_A_CH GS.../SH SH SUCTION SIDE SH DISCHARGE SIDE 1 3 Q [Imp gpm] 1 3 Q [Imp gpm] 1 3 Q [US gpm],,1 Hc [m],1,,1 Hc [ft] Hc [m] 1 3 Q [US gpm] 3 1 A 1 Hc [ft],3 A,1 8,,1,8,,, 1,, Hc [m] Hc [m] Col 1 vs Col Col vs Col 1 Col vs Col 1 B Hc [ft],1,1,1 Col 1 vs Col Col vs Col 1 Col vs Col 1 B,,3 Hc [ft] 1 3,8,, 1,,,1 8 Q [m1 3 /h] 8 1 1 1 1 Q [l/min] 77_A_CH,, 8 Q [m1 3 /h] 8 1 1 1 1 Q [l/min] 771_A_CH The declared curves are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. Hc (A): Pressure drop curve with check valve installed on the delivery side of the pump. Hc (B): Pressure drop curve with check valve installed on the suction side of the pump. The pressure drops do not consider the pressure drops distributed in the manifold. 111

BOOSTER SETS, GS.../SH SERIES Hc PRESSURE SURE DROP CURVE SH SUCTION SIDE SH DISCHARGE SIDE 1 3 Q [Imp gpm] 1 3 Q [Imp gpm] Hc [m] 1 3 Q [US gpm] 3 1 1 Hc [ft] 1 3 Q [US gpm] 8 Hc [m] Hc [ft] A 8 1 A 1 1 Hc [m] Col 1 vs Col Col vs Col 1 Col vs Col 1 Hc [ft] Hc [m] 8 Col 1 vs Col Col vs Col 1 Col vs Col 1 3 Hc [ft] 1 B 3 B GS.../SH 1 8 1 1 Q [m1 3 /h] 1 Q [l/min] 771_A_CH 1 8 1 1 Q [m1 3 /h] 1 Q [l/min] 77_A_CH SH 8 SUCTION SIDE SH 8 DISCHARGE SIDE 1 3 Q [Imp gpm] 1 3 Q [Imp gpm] Hc [m] 1 3 Q [US gpm] 7 1 3 1 Hc [ft] 1 3 Q [US gpm] 7 8 Hc [m] Hc [ft] A 8 1 A 1 1 Hc [m] Col 1 vs Col Col vs Col 1 Col vs Col 1 Hc [ft] Hc [m] 8 Col 1 vs Col Col vs Col 1 Col vs Col 1 B 3 Hc [ft] 1 B 3 1 1 1 Q [m 3 /h] 1 3 Q [l/min] 77_A_CH 1 Q [m 3 /h] 1 3 Q [l/min] 771_A_CH The declared curves are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. Hc (A): Pressure drop curve with check valve installed on the delivery side of the pump. Hc (B): Pressure drop curve with check valve installed on the suction side of the pump. The pressure drops do not consider the pressure drops distributed in the manifold. 11

ACCESSORIES SORIES ACCESSORIES SORIES 113

DIAPHRAGM TANKS The booster sets are ready for installation, directly on the manifold, of -litre diaphragm tanks, one for each pump. The sets are also equipped with caps to close off the unused couplings. Larger tanks can also be connected to the unused end of the discharge manifold. For proper sizing of the tank please refer to the technical appendix. Kits featuring the following accessories are available on request: diaphragm tank; on-off ball valve; operating instructions; packaging. DIAPHRAGM TANK KIT Volume PN DIMENSIONS (mm) Materials Litres bar ø A B Valve Diaphragm Vessel Valve 8 8 39 1" FF EPDM Painted steel Nickel-plated brass 8 7 1" FF EPDM Painted steel Nickel-plated brass 1 7 1" FF EPDM Painted steel Nickel-plated brass 1 7 1" FF EPDM Painted steel Nickel-plated brass 1 7 7 1" FF Butyl Stainless steel AISI 31 Stainless steel COUNTERFLANGE KIT gcom-vmb_en_b_td Manifolds up to 3" in diameter are usually supplied with threaded couplings and caps on unused end. Counterflange coupling kits made of zinc-plated or stainless steel are available on request. The counterflange kits are equipped with: - threaded flange. - gasket and bolts/screws. - threaded counterflange (weld-on type for 3" diameter). ACCESSORIES SORIES THREADED COUNTERFLANGES KIT DIMENSIONS (mm) HOLES TYPE DN ø C ø A B ø D H ø F N PN " Rp 1 1 18 " ½ Rp ½ 1 18 3 18 1 3" 8 Rp 3 1 17 7 18 8 1 Gcom-ctf-tonde-f-en_a_td WELD-ON COUNTERFLANGES KIT DIMENSIONS (mm) HOLES TYPE DN ø C ø A B ø D ø F N PN " 1 19 1 18 1 "1/ 77 18 18 1 3" 8 9 1 18 8 1 " 1 11 18 18 8 1 " 11, 1 18 8 1 " 17, 8 8 1 8" 1, 9 3 1 1 1" 7, 3 9 1 1 1" 3 37, 1 3 1 1 Gcom-ctf-tonde-s-en_c_td 11

RUBBER EXPANSION JOINT KIT The anti-vibrating joints or compensation joints can be used in order to absorb deformations, expansions, noises in the piping and to reduced ram blows. Moreover they can resist a high degree of empty that allows the absorption of negative expansions for depression. Being of elastic material it can be become deformed and be dilated facilitating therefore the installation, that it becomes simpler and fast, also in which the piping they are not aligned. It does not need assembly joints. TABELLA 1 TABLE 1 GIUNTI ELASTICI A-B-C-D non possono essere sommati A-B-C-D can not be cumulative L A B C D RUBBER EXPANSION JOINT COMPRESSIONE ESTENSIONE SPOSTAMENTO FLESSIONE ANGOLARE COMPRESSION EXTENSION TRANSVERSE ANGULAR MOVEMENT mm mm mm mm ( ) DN 3 1"1/ 9 8 8 1"1/ 9 8 8 " 8 8 "1/ 1 1 1 8 3" 13 1 1 1 " 13 18 1 1 " 17 18 1 1 " 18 18 1 1 8" 1 1" 1 3 1" 1 3 1" 1 1" 1 18" 1 " 1 GD_JOINT_A_TD ACCESSORIES SORIES VIBRATION DAMPERS DIMENSIONS (mm) TYPE SHORE ø A H L M VIBRATION DAMPER PX 18 VIBRATION DAMPER PX3 3 3 8 VIBRATION DAMPER P1X 1 1 Note: Available versions M/F and F/F bst-ant-piedini-en_a_td 1

DRY RUNNING PROTECTION SYSTEMS Dry run shutdown systems should be installed to protect the pumps in case of insufficient water supply. FLOAT SWITCH PROTECTION METHOD The float switch protection system is used when the water supply comes from open tanks. A float switch immersed in the tank is connected to the electrical panel. If the water supply is insufficient, the float switch opens the electric contact and the pumps stop running. Gcom-pms1_a_dd ELECTRODE PROBE PROTECTION METHOD The electrode probe protection system is used when the water supply comes from open tanks or wells. A set of three probes is connected directly to the electronic board in the electrical panel. With the three electrodes immersed in the water, the relay on the electronic board closes the contact, enabling the starting of the pumps. If the water supply is insufficient, the control circuit opens the electric contact and the pumps stop running. Gcom-pms_a_dd ACCESSORIES SORIES MINIMUM PRESSURE SURE SWITCH PROTECTION METHOD The minimum pressure switch protection system is used when the water supply comes from water networks or pressurized tanks. The pressure switch is connected to the electronic board in the electrical panel. If the water supply is insufficient, the pressure switch opens the electric contact and the pumps stop running. Gcom-pms3_a_dd 11

TECHNICAL APPENDIX TECHNICAL APPENDIX 117

WATER REQUIREMENTS IN CIVIL USERS Determination of the water requirement depends on the type of users and contemporaneity factor. The calculation may be subject to regulations, standards or customs that may vary from country to country. The calculation method shown below is an example based on practical experience, designed to provide a reference value and not a substitute for detailed analytical calculation. Water requirements in condominiums The consumption table shows the maximum values for each delivery point, depending on the plumbing amenities. MAXIMUM CONSUMPTION FOR EACH DELIVERY POINT TYPE CONSUMPTION (l/min) Sink 9 Dishwasher 1 Washing machine 1 Shower 1 Bathtub Washbasin Bidet Flush tank WC Controlled flushing system WC 9 G-at-cm_a_th The sum of the water consumption values of each delivery point determines the maximum theoretical requirement, which must be reduced according to the contemporaneity coefficient, because in actual fact the delivery points are never used all together. f = 1 (,87x Nrx Na) Coefficient for apartments with one bathroom and flush tank WC f = 1 (,87x Nrx Na) Coefficient for apartments with one bathroom and controlled flushing system WC TECHNICAL APPENDIX f f = = 1,3 (,x Nrx Na),8 (,77x Nrx Na) Coefficient for apartments with two bathrooms and flush tank WC Coefficient for apartments with two bathrooms and controlled flushing system WC f= coefficient; Nr= number of delivery points; Na= number of apartments The table of water requirements in civil users shows the maximum contemporaneity flow-rate values based on the number of apartments and the type of WC for apartments with one bathroom and two bathrooms. As regards apartments with one bathroom, 7 drawing points have been taken into consideration, while 11 points have been considered for apartments with two bathrooms. If the number of drawing points or apartments is different, use the formulas to calculate the requirement. 118

TABLE OF WATER REQUIREMENTS IN CIVIL USERS NUMBER OF WITH FLUSH TANK WC WITH CONTROLLED FLUSHING SYSTEM WC APARTMENTS 1 1 FLOW RATE (l/min) 1 3 79 8 111 3 8 13 3 79 11 7 71 88 13 17 78 97 18 193 7 8 1 8 8 9 11 171 3 9 9 119 181 3 1 1 191 9 11 131 1 1 11 137 9 73 13 11 13 18 8 1 119 18 9 13 3 3 3 1 17 8 3 17 131 13 9 3 18 13 18 33 19 138 17 3 33 1 177 7 3 1 181 77 31 19 18 83 39 3 19 9 378 19 9 38 8 198 3 39 1 38 1 7 1 31 9 8 18 9 3 17 9 171 13 3 3 17 17 331 31 3 187 3 37 38 98 13 8 8 7 7 3 93 8 8 3 8 1 319 87 3 7 331 9 7 7 3 3 8 8 83 3 7 8 9 3 7 7 9 31 37 73 77 9 39 38 89 77 1 317 39 787 1 37 33 83 1 37 8 7 93 1 1 7 99 18 3 811 8 9 8 111 For seaside resorts, a flow rate increased by at least % must be considered. G-at-fi_a_th TECHNICAL APPENDIX 119

WATER REQUIREMENTS FOR COMMUNITY BUILDINGS The requirements of buildings intended for specific uses, such as offices, residential units, hotels, department stores, nursing homes and so on, are different from those of condominiums, and both their global daily water consumption and the maximum contemporaneity flow rate are usually greater. The diagram of water requirements for community buildings shows the maximum contemporaneity flow rate of some types of communities, for guidance. These requirements must be determined case by case with the utmost accuracy, using analytical calculation methods, according to particular needs and local provisions. TECHNICAL APPENDIX For seaside resorts, the flow rate must be increased by at least %. 1= Offices (N. of people) = Department stores (N. of people) 3= Nursing homes (N. of beds) = Hotels, residences (N. of beds) 1

USE OF BOOSTER SET Water is usually delivered by public supply systems and the pressure is generally sufficient for the proper operation of the users water and sanitary equipment. When this pressure is not sufficient, booster sets are employed to increase water pressure and ensure an acceptable minimum value at the furthest points. Therefore, the water supply to a building, group of buildings or to a system in general can be considered satisfactory when all the user points can deliver the required quantity of water. Set connection methods (intake side) Water can be supplied to a booster set in two ways: 1 - By installing a water storage tank between the user s offtake and the booster set (indirect connection, fig. 7.1.1). - By connecting the booster set directly between the user s offtake and the system (direct connection, fig. 7.1.1). The indirect connection does not allow the water system pressure to be utilized. Therefore, it requires pumps with greater head. The direct connection allows the water system pressure to be utilized, provided the pressure fluctuation ( p) does not exceed 1 bar. If it does, a pressure reducer must be installed for proper operation of the booster set. INDIRECT UTILISATION SUPPLY USER S OFFTAKE WATER STORAGE TANK BOOSTER SET WATER PIPE UNDER PRESSURE (1) SUPPLY DIRECT USER S OFFTAKE PRESSURE REDUCER IF p > Ibar BOOSTER SET TECHNICAL APPENDIX (1) BY PIPE UNDER PRESSURE WE MEAN A WATER SYSTEM, A CLOSED TANK, ETC. () IN THE CASE OF A WATER SYSTEM INSTALL A CHECK VALVE (A) OR A DISCONNECTING DEVICE (B), UNLESS OTHERWISE PROVIDED BY LOCAL REGULATIONS fig. 7.1.1 11

Water supply systems in civil buildings The configuration of the supply system must comply with the following conditions: - The minimum pressure ensuring the proper operation of the equipment must be guaranteed at the most unfavourable drawing point (1. bar for valves and flush tank WC, and bar for controlled flushing system WC). - At the most favourable drawing point, pressure must not exceed bar. Once these parameters have been satisfied, in relation to the height of the building and to the set intake conditions, the water supply system can have one of the following configurations: SUPPLY SUPPLY A) THE SET SERVES THE ENTIRE BUILDING B) THE SET SERVES THE ENTIRE BUILDING, BUT THE LOWER FLOORS ARE CONNECTED THROUGH A PRESSURE REDUCER SINCE THE PRESSURE TO THE NEAREST UTILIZATION POINTS IS TOO HIGH fig. 7.1. fig. 7.1.3 TECHNICAL APPENDIX SUPPLY WATER PIPE UNDER PRESSURE BOOSTER SET SUPPLY WATER PIPE UNDER PRESSURE BOOSTER SET C) THE SET SERVES THE UPPER FLOORS, WHEREAS THE LOWER FLOORS D) THIS CASE RESEMBLES THE PREVIOUS ONE ARE SUPPLIED BY THE WATER PIPE UNDER PRESSURE EXCEPT THAT PRESSURE REDUCERS NEED TO BE INSTALLED ON SOME OF THE LOWER FLOORS fig. 7.1. fig. 7.1. 1

DETERMINING THE HEAD OF THE SET AND INTAKE CONDITIONS Level intake The delivery head of the set (H tot) is the sum of: - He : geodetic difference in level between the set and the furthest delivery point. - Hc : flow resistance along all the pipes and through other system components, such as valves, filters, etc.. - Hr : pressure required at the most unfavourable point. H tot = He+Hc+Hr Intake with positive head In this case, the necessary delivery head (H tot) will be reduced by the inlet pressure value (Hi). H tot = He+Hc+Hr- Hi Intake with negative head When the pumps suck from an underground tank or well, the necessary head will be increased by the value of the intake height (Ha):. H tot = He+Hc+Hr+ Ha In this case the intake height must be considered very carefully, bearing in mind that an excessive difference in level between the water storage tank and the set, or the wrong sizing of the intake pipe, can have adverse effects on pump operation, such as cavitation and unpriming. TECHNICAL APPENDIX 13

NPSH TECHNICAL APPENDIX The minimum operating values that can be reached at the pump suction end are limited by the onset of cavitation. Cavitation is the formation of vapour-filled cavities within liquids where the pressure is locally reduced to a critical value, or where the local pressure is equal to, or just below the vapour pressure of the liquid. The vapour-filled cavities flow with the current and when they reach a higher pressure area the vapour contained in the cavities condenses. The cavities collide, generating pressure waves that are transmitted to the walls. These, being subjected to stress cycles, gradually become deformed and yield due to fatigue. This phenomenon, characterized by a metallic noise produced by the hammering on the pipe walls, is called incipient cavitation. The damage caused by cavitation may be magnified by electrochemical corrosion and a local rise in temperature due to the plastic deformation of the walls. The materials that offer the highest resistance to heat and corrosion are alloy steels, especially austenitic steel. The conditions that trigger cavitation may be assessed by calculating the total net suction head, referred to in technical literature with the acronym NPSH (Net Positive Suction Head). The NPSH represents the total energy (expressed in m.) of the liquid measured at suction under conditions of incipient cavitation, excluding the vapour pressure (expressed in m.) that the liquid has at the pump inlet. To find the static height hz at which to install the machine under safe conditions, the following formula must be verified: hp + hz (NPSHr +.) + hf + hpv where: hp is the absolute pressure applied to the free liquid surface in the suction tank, expressed in m. of liquid; hp is the quotient between the barometric pressure and the specific weight of the liquid. hz is the suction lift between the pump axis and the free liquid surface in the suction tank, expressed in m.; hz is negative when the liquid level is lower than the pump axis. hf is the flow resistance in the suction line and its accessories, such as: fittings, foot valve, gate valve, elbows, etc. hpv is the vapour pressure of the liquid at the operating temperature, expressed in m. of liquid. hpv is the quotient between the Pv vapour pressure and the liquid s specific weight., is the safety factor. 1 The maximum possible suction head for installation depends on the value of the atmospheric pressure (i.e. the elevation above sea level at which the pump is installed) and the temperature of the liquid. To help the user, with reference to water temperature ( C) and to the elevation above sea level, the following tables show the drop in hydraulic pressure head in relation to the elevation above sea level, and the suction loss in relation to temperature. Water temperature ( C) 8 9 11 1 Suction loss (m),,7,, 7,, 1, Elevation above sea level (m) 1 3 Suction loss (m), 1,1 1,,,7 3,3 Friction loss is shown in the tables at pages 17-18 of this catalogue. To reduce it to a minimum, especially in cases of high suction head (over - m.) or within the operating limits with high flow rates, we recommend using a suction line having a larger diameter than that of the pump s suction port. It is always a good idea to position the pump as close as possible to the liquid to be pumped. Make the following calculation: Liquid: water at ~ C γ = 1 kg/dm 3 Flow rate required: 3 m 3 /h Head for required delivery: 3 m. Suction lift: 3, m. The selection is an FHE -/7 pump whose NPSH required value is, at 3 m 3 /h, di, m. For water at C hp = Pa / γ = 1,33m, hpv = Pv / γ =,17m (,171 bar) The Hf flow resistance in the suction line with foot valves is ~ 1, m. By substituting the parameters in formula 1 with the numeric values above, we have: 1,33 + (-3,) (, +,) + 1, +,17 from which we have:,8 >, The relation is therefore verified. 1

TECHNICAL APPENDIX VAPOUR PRESSURE PS VAPOUR PRESSURE AND ρ DENSITY OF WATER TABLE t T ps ρ t T ps ρ t T ps ρ C K bar kg/dm 3 C K bar kg/dm 3 C K bar kg/dm 3 73,,11,9998 38,,71,987 1 393, 1,98,99 1 7,,7,9999 39,,111,98 1 39,,1,91 7,,7,9999 7 33,,17313,98 1 397,,,939 3 7,,78,9999 8 331,,1817,98 1 399,,3933,9379 77,,813 1, 9 33,,191,9837 18 1,,3,93 78,,87 1, 333,,199,983 13 3,,713,93 79,,93 1, 1 33,,8,98 13,,87,938 7 8,,11,9999 33,,18,981 13 7, 3,1,9311 8 81,,17,9999 3 33,,8,981 13 9, 3,3,99 9 8,,117,9998 337,,391,9811 138 11, 3,1,97 1 83,,17,9997 338,,1,98 1 13, 3,1,98 11 8,,131,9997 339,,,9799 18,,,91 1 8,,11,999 7 3,,733,9793 8,,33,911 13 8,,197,999 8 31,,8,9788 1 33,,181,973 1 87,,97,9993 9 3,,98,978 1 38, 7,8,9 88,,17,999 7 33,,311,9777 17 33, 7,9,8973 1 89,,1817,999 71 3,,33,977 17 8, 8,9,891 17 9,,193,9988 7 3,,339,97 18 3, 1,7,889 18 91,,,9987 73 3,,33,97 18 8, 11,33,88 19 9,,19,998 7 37,,39,973 19 3, 1,1,87 93,,337,9983 7 38,,38,978 19 8, 13,987,87 1 9,,8,9981 7 39,,19,971 73,,,87 9,,,9978 77 3,,189,973 78, 17,3,888 3 9,,88,997 78 31,,3,979 1 83, 19,77,88 97,,98,997 79 3,,7,973 88, 1,,87 98,,31,9971 8 33,,73,971 93, 3,198,83 99,,33,998 81 3,,931,971 98,,1,8339 7 3,,3,99 8 3,,133,97 3 3, 7,97,873 8 31,,3778,993 83 3,,3,997 3 8, 3,3,8 9 3,,,99 8 37,,7,991 13, 33,78,813 3 33,,1,997 8 38,,78,98 18, 3,3,8 31 3,,91,99 8 39,,11,978 3, 39,77,799 3 3,,73,991 87 3,,9,971 8, 3,,791 33 3,,9,997 88 31,,9,9 33,,93,7839 3 37,,318,99 89 3,,79,98 38,,877,779 3 38,,,99 9 33,,711,9 7 3,,8,778 3 39,,9,9937 91 3,,781,9 7 8, 9,9,793 37 31,,7,9933 9 3,,71,938 8 3,,,7 38 311,,,993 93 3,,789,93 8 8, 9,18,7 39 31,,991,997 9 37,,81,9 9 3, 7,1,731 313,,737,993 9 38,,83,91 9 8, 8,37,73 1 31,,7777,9919 9 39,,879,91 3 73, 8,97,71 3,,8198,99 97 37,,99,9 3 78, 9,1,717 3 31,,939,9911 98 371,,93,99 31 83, 98,7,9 317,,91,997 99 37,,977,98 3 88,,1,791 318,,98,99 1 373, 1,133,981 3 93, 11,89,9 319,,18,9898 1 37, 1,878,97 3 98, 1,,1 7 3,,11,989 1 377, 1,18,9 33 3, 18,3, 8 31,,111,9889 1 379, 1,,937 3 13, 1,,1 9 3,,1173,988 18 381, 1,339,9 3 3, 1,3,73 33,,133,988 11 383, 1,37,97 3 33, 18,7,7 1 3,,191,987 11 38, 1,31,991 37 3, 1,,18 3,,1313,9871 11 387, 1,3,97 37, 7,3 1,,3 3 3,,193,98 11 389, 1,7,9 37,,,98 118 391, 1,88,9 G-at_npsh_a_sc TECHNICAL APPENDIX

TECHNICAL APPENDIX CHOOSING AND SIZING THE SURGE TANK The purpose of the surge tank is to limit the number of hourly starts of the pumps, placing part of its stock of water, which is maintained under pressure by the air above it, at the disposal of the system. The surge tank can be of the air cushion or diaphragm type. In the air cushion version there is no clear separation between air and water. Since part of the air tends to mix with water, it is necessary to restore it by means of air supply units or a compressor. In the diaphragm version, neither air supply units nor compressor are needed, as contact between air and water is prevented by a flexible diaphragm inside the tank. The following method, which is used to determine the volume of a surge tank, is valid both for horizontal and vertical surge tanks. When calculating the volume of the surge tank, it is generally sufficient to consider the first pump only. AIR-CUSHION SURGE TANK It is determined in relation to flow rate, pump pressure, and number of starts per hour allowed by the motor. 1, x Qp x (Pmax + 1) Va = x Z x (Pmax - Pmin) where: Va = Total volume of the air-cushion surge tank in m 3 Qp = Average pump flow rate in m 3 /h Pmax = Maximum pressure setting (wcm) Pmin = Minimum pressure setting (wcm) Z = Maximum number of starts per hour allowed by the motor Warning! By pump flow rate we mean the average between the flow rate at the maximum pressure switch setting (Qmax) and the flow rate at the minimum pressure switch setting (Qmin), i.e.: Example: CN 3-1/ pump Pmax = 3 mca Pmin = mca Qp = 18 m 3 /h Z =3 Qp = Qmax + Qmin (m 3 /h) Va = 1, x 18 x (3 + 1) =,788 m x 3 x (3 - ) 3 A 7-litre surge tank is therefore required. DIAPHRAGM TANK If you decide to use a diaphragm tank, the volume will be lower than that of the air-cushion tank. It can be calculated with the following formula: Vm = Qp x 1 x Z 1 - (Pmin - ) Pmax where: Vm = Total volume of the air-cushion surge tank in m 3 Qp = Average pump flow rate in m 3 /h Pmax = Maximum pressure setting (wcm) Pmin = Minimum pressure setting (wcm) Z = Maximum number of starts per hour allowed by the motor Example: CN 3-1/ pump Pmax = 3 mca Pmin = mca Qp = 18 m 3 /h Z =3 Vm = Qp x 1 =, m 3 x Z (Pmin - ) 1 - Pmax A -litre surge tank is therefore required. Approximate comparison between air-cushion tanks and diaphragm tanks, as regards some pressure switch setting values NOMINAL NOMINAL CAPACITY PRESSURE SWITCH PRESSURE SETTING SWITCH (bar) min/max SETTING CAPACITY OF AIR 1,/, /3,/3, 3/ 3,/, /,/, /,/, OF AIR CUSHION TANK1,/, /3,/3, 3/ 3,/, /,/, /,/, /7 TANK (litres) (litres) NOMINAL CAPACITY OF DIAPHRAGM TANK (litres) NOMINAL CAPACITY OF DIAPHRAGM VESSEL (litres) 1 N. ball types tanks/cylinder type tanks or l Export tank or 1-litre tanks (Ispesl tested) table N ball type vessels/cylinder type vessels 1 or l Export tank or 1-litre vessels (ISPESL tested) 1 1 3 3 3 3 1 1 + + 3 + + + 3 + + + + + 3 + + + + 3 s_swp-en_a_th tab. 7..1 1

TABLE OF FLOW RESISTANCE IN 1 m OF STRAIGHT CAST IRON PIPELINE (HAZEN-WILLIAMS FORMULA C=1) FLOW RATE NOMINAL DIAMETER in mm and INCHES m 3 /h l/min 3 8 1 17 3 3 1/" 3/" 1" 1 1/" 1 1/" 1/" 3" " " " 7" 8" 1" 1" 1" 1", 1 v,9,3,3,1,13 hr 1 3,9 1,33,,13 The hr values must be multiplied by:,9 v 1,,8,1,31,.71 for galvanized or painted steel pipes hr 33,9 8,3,8,8,9. for stainless steel or copper pipes 1, v 1,89 1,,8,1,7,17.7 for PVC or PE pipes hr 7,7 1,1,79 1,,9,1 1, v,3 1,33,8,,33,1 hr 87, 1, 7,,18,73, 1,8 3 v,83 1,9 1,,,, hr 1 3,1 1,1 3, 1,3,3,1 3 v 3,3 1,8 1,19,73,,3 hr 1, 13,, 1,37,, v,1 1,3,83,3,3, hr 1, 17,3,19 1,7,9,1 3 v, 1,7 1,,,, hr 77,,1 7,8,,89, 3, v 3,18, 1,,8,1,3 hr 18 3, 11, 3,71 1,,3, 7 v 3,7,38 1,,93,9,3 hr 1 8,7 1,,93 1,,,8 8 v,,7 1, 1,,8, hr 18,3 18,7,3,13,9, 9 1 v v 3, 3, 1,87,7 1,19 1,33,7,8,,,3,33 hr hr 77, 9,1 3,3 8,3 7,8 9,, 3,,7,9,7,33 7, 9 v v, 3,11,9 1,99 1, 1,7 1,,7,3,,1,3 hr hr 1 9,9,8, 1,,8,8 1,9 1,3,9,9,3 1, 17 v 3,3,3 1,9,88,8,37 hr 79,7,9 9,7,3,9,31 1 v,, 1,7 1,1,, hr 1 3, 11, 3,3 1,18, 18 3 v v,18 3,98 3,3,,1 1,1 1, 1,,83,,3,1,3 hr hr 7,8,, 17,,8,89,9 1,78,8,,8, 3 3 7 v v v v,31,3,1,9 3,, 3, 3,,1,1 1,99,3 1,33 1, 1,7 1,9,8 1,,8,9,,8,7,,38,7,,9 hr hr hr hr 1 187 88, 118 1,8 3,,7 3,8 11, 17, 8,98 11,9,,1 3,3,3 1,3,1 1, 1,3,8,73,,,,3,, 8 8 9 v v,79 7,,,,,99 1,7 1,91 1,9 1,,7,8,, hr hr 1 188,,3,3 19,,1,1 1,7,1,7,89,3, 1 v,3 3,3,1 1,3,9,9,3 hr 3, 3,1 7,79,3 1,8,1,7 7 v,8,, 1,7 1,18,87, hr 9, 3,9 11,8 3,97 1,3,77, 9 17 v v 7, 8,79,98,81 3,18 3,7,,38 1, 1, 1, 1,1,8,93 hr hr 13 179 8,9,1 1, 1,9,7 7,,9 3, 1,8 1,,,7 1 v,3,,7 1,89 1,39 1,,8 hr 83,3 8,1 9,8 3,9 1,8,9,3 v 8,9,31 3,,3 1,73 1,33,8 hr 1, 1,3,89,78 1,,9 18 3 v,37,8,83,8 1,9 1,,71 hr 9,,1 8, 3,9,3,9,8 1 3 v 7,3,7 3,3,3 1,8 1,19,83 hr 79,1,7 11,,18,71,91,38 v 8,9, 3,77,77,1 1,3,9 hr 11 3, 1,1, 3, 1,17,8 3 v,79,7 3,7, 1,7 1,18 hr 1, 1, 1,,3 1,77,73 3 v 8,,,1 3,18, 1, hr 7,3 9,8 1,1 7,33,7 1, 7 v,1,8 3,7,38 1, 1,1 hr 39, 18,7 9,7 3,9 1,3, 8 8 v 7,,,,7 1,89 1,39 hr,7 3,9 1,9,1 1,73,8 9 v 8,9,,78 3,,1 1, 1,19 hr 3, 9,8,,,1 1,,3 1 G-at-pct_a_th v,93,31 3,,3 1,73 1,33 hr 3, 18,9,3, 1,, hr = flow resistance for 1m of straight pipeline (m) V = water speed (m/s) TECHNICAL APPENDIX 17

FLOW RESISTANCE TABLE OF FLOW RESISTANCE IN BENDS, VALVES AND GATES The flow resistance is calculated using the equivalent pipeline length method according to the table below: ACCESSORY TYPE 3 8 1 3 Equivalent pipeline length (m) bend,,,,,,,9 1,1 1, 1,9,,8 9 bend,,,9 1,1 1,3 1,,1, 3, 3,9,7,8 9 smooth bend,,,,,9 1,1 1,3 1,7 1,9,8 3, 3,9 Union tee or cross 1,1 1,3 1,7,1, 3,,3,3, 7, 1,7 1,8 Gate - - -,,,,,,,9 1,1 1,3 Non return valve 1,1 1, 1,9, 3, 3,,7,9 7, 9, 11,8 13,9 The table is valid for the Hazen Williams coefficient C = 1 (cast iron pipework). For steel pipework, multiply the values by 1.1. For stainless steel, copper and coated cast iron pipework, multiply the values by 1.8. When the equivalent pipeline length has been determined, the flow resistance is obtained from the table of flow resistance. The values given are guideline values which are bound to vary slightly according to the model, especially for gate valves and non-return valves, for which it is a good idea to check the values supplied by the manufacturers. DN G-a-pcv_a_th TECHNICAL APPENDIX 18

Air supply unit The most commonly used air supply unit model is the depression type, which uses the depression produced by the pump suction. fig. 7.. - The air supply unit consists of a body made of plastic material suitable for foodstuffs (1), a spherical rubber shutter (), an upper brass union (3) with an air valve (), a Venturi tube (), and a flexible pipe () to be connected to the pump intake. fig. 7.. - The air accumulated inside the body pushes the rubber ball () to the bottom, thus blocking the passage. At this point the valve closes and the rubber ball prevents the air accumulated inside the body of the air supply unit from reaching the pump intake. Air supply unit operation fig. 7..3 - When the pump starts up, the intake pressure is lower than the pressure in the surge tank. This difference causes water to flow from the surge tank to the pump intake, through the air supply unit. fig. 7.. - When the pump stops the depression ceases and a flow of water is produced, which lifts the ball and pushes the air in the body of the supply unit into the tank. fig. 7.. - The flow of water that passes through the Venturi tube () generates a depression and allows the opening of the air valve (). As a consequence, air enters the body of the supply unit. Air supply unit selection tank TANK TANK AVERAGE AVERAGE PRESSURE SETTING CAPACITY bar bar L L., 3. 3,.,.,., 7. 7, 1 1 LOW 3 LOW 3 LOW 1 7 1 LOW 1 7 1 LOW 3 LOW LOW 3 LOW g_air-en_a_th tab. 7..7 This cycle is repeated each time the pump starts up until the required quantity of air has accumulated. To ensure proper system operation, no check valve must be mounted between the pump delivery outlet and the surge tank, as it would impede the return flow of water through the pump. TECHNICAL APPENDIX 19

ASSESSMENT OF PROBABLE DEMAND (VALID IN U.K. ONLY) The method adopted is based on loading unit values as detailed in the Plumbing Engineering Design Guide published by the Institute of Plumbing. When designing a hot or cold water supply system an assessment must be made to obtain the maximum probable simultaneous demand. Depending on the type of services being provided it rarely occurs for all the appliances to be used at the same time therefore the design usually allows for a peak usage which is less than the maximum. Probable demand will depend on the type of building and its use, type of appliances installed and frequency of use. The simultaneous demand in most installations can be calculated with an adequate degree of accuracy using the loading unit concept. The usage patterns and types of appliances in different installations will vary greatly. Sports and Leisure centres for example are usually calculated directly by the flow rates of each appliance, without diversity factors. Each case will need to be looked at in its own right and assessed accordingly. Judgement of the designer must prevail. Loading unit values vary for each type of appliance. A loading unit has no precise value in terms of litres per second. See loading unit table below. By multiplying the total number of each appliance by the appropriate loading unit number and adding the resultant totals together, the recommended flow can be read from the chart. Loading unit table APPLIANCE Loading Recommended Unit Flow L/s LOADING UNITS 8 3 FLOW L/s 3 1 WC 1,,1 Wash basin (hot & cold) 3,3 Sink (hot & cold), Bath (hot & cold), Shower (hot & cold) 1, Washing machine,3 g_at_a_lu 1 8 8 3 Working Example 1. TECHNICAL APPENDIX A block of standard flats containing a total of 7 dwellings Each standard flat is assumed to have: 1 x Hand basin hot & cold = 3 L/U x 7 = 1 1 x WC cold only = 1. L/U x 7 = 1 x Shower hot & cold = 1 L/U x 7 = 7 1 x Sink hot & cold = L/U x 7 = 1 7 3 1.8.. Total Loading Unit =13. This figure can now be read from the chart opposite: total flow = 8. L/s 1.3 G_at_a 13

ASSESSING HEAD REQUIREMENT (VALID IN U.K. ONLY) The head required in a boosted cold water system consists of three components, static head, residual pressure and system friction losses. The values of these three components are added together to give the total required head at the system flow rate. Static head (He): This is the difference between the break tank low water line and the highest discharge point in the building. If the height of the build is not known, then.8-3. metres per floor can be used to assess the building height. Residual pressure (Hr): This is the pressure required at the highest outlet device, normally metres. Note: some modern showers may require higher pressures. System friction losses (Hc): The total losses through pipework, pipework fittings, valves, PRVs and all other equipment fed through the pumpset must be added to find the total system losses. On conventional systems that do not include excessive runs of pipe or specialised components a rough guide would be to allow. metres friction loss for each metre of static head. G_at a Hc Hr He H Example: Static head (He): Building height four floors @.8m each = 11.m + Residual pressure (Hr): Pressure at highest outlet = m + Friction loses (Hc): 11. (static head) x. =.m Total pump head required (H) = 31.7m (3.11 Bar) Pressure limitations The designer must ensure that adequate precautions are taken to ensure that the system is capable of withstanding the closed valve head produced by the pump set. In cases where closed valve pressures cannot be tolerated, pressure reducing valves should be fitted down stream of the booster set. PIPE SIZE SUCTION PIPE DELIVERY PIPE Velocity Pipework within the system should be sized to limit the velocity to the figures stated in table below. Higher velocities will lead to excessive noise, wear and higher running costs. BOOSTER SIZING What information do we require to size a booster set? m/s m/s Less than 8mm,,91 to 1,7 1-mm, 1, to 1, mm,7 1,8 and above,91 1,8 to,13 As a minimum we need to know: The total flow rate, or information to assess this. The total head at flow rate, or the height of building. If the pumps are to operate under positive head, or suction lift conditions. Where the set is to be sited, I.E. basement or roof. Preferred choice fixed of variable speed g_at_a_fs TECHNICAL APPENDIX Additional information if available: How to split the duty for particular applications I.E. duty/standby or duty/assist. The size and material of the connecting pipework. Is a Jockey pump required. 131

ACCESSORIES SORIES AIR SUPPLY UNITS FLOAT SWITCHES VALVES CYLINDER WATER TANK TECHNICAL APPENDIX NON-RETURN VALVES COUPLINGS PRESSURE TRANSMITTER 13