Automated Mirror Cover for Telescope Application. Needs Identification Document

Similar documents
Automated Mirror Cover for Telescope Application. Concept Generation and Selection Document

Department of Mechanical Engineering Northern Arizona University Flagstaff, AZ 86011

Second Generation Bicycle Charging Station. Engineering Analysis

NPOI Nitrogen Distribution. Engineering Analysis Document

Jerry Martin s Co 2 Snow Apparatus

Gas Cabinets and Valve Manifold Boxes: Applying CGA G13- Rev 2015 to Gas Delivery Equipment

Materials Performance November Nitrogen generator inhibits corrosion within fire protection systems

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

EZ-Tops World Wide, Inc Dome Pressure Test

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

SRI Jigger Tubes System

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Retractable Pool Cover

Best Practices Pneumatics Machine & Design. Written by Richard F. Bullers, CFPPS as published in Fluid Power Journal, July/August 2016

A NOVEL SENSOR USING REMOTE PLASMA EMISSION SPECTROSCOPY FOR MONITORING AND CONTROL OF VACUUM WEB COATING PROCESSES

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

OPERATING INSTRUCTIONS


INSTRUCTION MANUAL FOR EBA MINUTE SELF-CONTAINED SELF RESCUER (SCSR) Manual Number: NH13747 Revision: A, ECN 2384 September 7, 2001

Investigation of Thermal Effects of CO 2 on Earth-Atmosphere System

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

Customer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist

- Introduction: a) Metallized Paper & Film :The market Outlook The following diagram shows the estimated usage of the main metallized materials

PURPOSE OF THE POLICY

MATRIX-MG Series. Innovation with Integrity. Automated High-Performance Gas Analyzers FT-IR

DESIGN DATA. Dry 105a. September 5, 2008

MODEL NUMBER: P PORTABLE COMPRESSOR

MB-SP Series Solvent Purification System

MODEL NUMBER: P PORTABLE COMPRESSOR

High Precision Gauge Pressure Indicators

The Criticality of Cooling

RH800 & 2000 BASIC OPERATIONS

Gas Measurement Fundamentals Certification. Curriculum

Supporting Information for Micro-Collection of. Gases in a Capillary Tube: Preservation of Spatial

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

Industrial Compressed Air. Ultrasonic Leak Detection Survey Guide

Right-Angle Tube Roller Model


MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

Related Products: Auto Drain Valve. Model/Specifications. Model

200 PSI HIGH-FLOW AIR SOURCE KIT

200 PSI FAST-FILL AIR SOURCE KIT

Another convenient term is gauge pressure, which is a pressure measured above barometric pressure.

This program shall contain, as a minimum, the following components:

PDY TON HYDRAULIC CRIMPING TOOL WARNING

MMS Mercury Monitoring System for Natural Gas

Rev. 1. Cryogenics Thermoflasks. 2122, 2123, 2124, 2129, and 2130

EHS Laboratory Guidance: Cryogenic Material

Instruction Sheet. Important Note: Information that requires special emphasis. Note: Information that supplements points in the main text.

Instrumentation & Data Acquisition Systems

Ocean Observatories Initiative. Coastal & Global Scale Nodes. Hydrogen Safety. OOI Surface Mooring Hydrogen Safety Review

Hyquest Solutions Pty Ltd

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

A It is halved. B It is doubled. C It is quadrupled. D It remains the same.

REL-510H WARNING NOTICE 12 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD

HumiSys HF High Flow RH Generator

ATMOSPHERIC CIRCULATION

Installation, Operation and Maintenance Manual for Back Pressure Regulator

INSTRUCTOR RESOURCES

Viva TPS. TS11/15 Total Stations Check and Adjust Procedure. October Summary

Nitrogen Advantage. Better Tire Pressure Retention. Improved Fuel Economy. Extended Tread Life. Elimination of Oxidation. Reduction in Tire Failures

Dynamics of bubble rising at small Reynolds numbers

Cable Pressurization Buffering

ECS Protector Nitrogen Inerting Vent (PAV-WN)

2016 International Perforating Symposium May Galveston, Texas

INSTRUCTION MANUAL EBA-75 CLOSED-CIRCUIT ESCAPE RESPIRATOR (CCER) CAPACITY 3

Bonding Reliability Testing for Wafer Level Packaged MEMS Devices

Flow meter. bellow vaporizer. APL valve. Scavenging system

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS General Certificate of Education Ordinary Level

VACUUM TESTING PRECAST CONCRETE MANHOLES

FCTechnik. flox[control] Gas Control Units for Aluminium Production. for aluminium production flox[control] flox[on] FC Technik 1

GILMONT ACCUCAL FLOWMETERS

Title: Standard Operating Procedure for Sabio 2010 and 4010 Dilution Calibrator

Pressure Regulators. Operating Instructions. Instrumentation

PTFE-SINGLE GLASS FLOW METERS

Navy Fighter Pilots Tolerate Higher-G Maneuvers Thanks to Oxygen Regulator Bellows

Equipment Operating Procedure Glove Box

Training for Proofmaster M/S/Automat. Functional principle for airtightness testing

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS

Inert Atmosphere Guide

Cryogenic Materials Operating Procedure and Safety Requirements

SPH 4C Unit 4 Hydraulics and Pneumatic Systems

Third measurement MEASUREMENT OF PRESSURE

Petro-Chemical & Analyzer Sampling Systems

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

GAS STRUT SAFETY INFORMATION

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

A Journal of Practical and Useful Vacuum Technology. By Phil Danielson

Outline Chapter 7 Waves

Tri-Tech Medical Inc.

5.0 INSPECTING, FILLING AND LABELING SMALL CYLINDERS

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

Petro-Chemical & Analyzer Sampling Systems

Finding leaks in Main Cryogenic Heat Exchangers without shutdown

CONTROL SOLUTIONS DESIGNED TO FIT RIGHT IN. Energy Control Technologies

Gases and welding distributors continue

The Kinetic-Molecular Theory of Gases based on the idea that particles are always in motion

Positive displacement proportioning of two-component epoxy intumescent coatings for passive fire protection

8.1 Calibration of gas sensors

Transcription:

Automated Mirror Cover for Telescope Application By Rogelio Blanco, Miles Dehlin, Leland Doyle, Salazar Grey, Katherine Hewey, and Paul Owen Team 8 Needs Identification Document Submitted towards partial fulfillment of the requirements for Mechanical Engineering Design Fall 2012 Department of Mechanical Engineering Northern Arizona University Flagstaff, AZ 86011

Introduction The NPOI (Navy Precision Optical Interferometer) located at the top of Anderson Mesa in Flagstaff, Arizona, is a United States Naval Observatory (USNO). This facility uses a series of expensive aluminum coated mirrors to reflect starlight down vacuum tubes, where the sunlight is then captured by sensors. The data is then analyzed by astronomers to produce a high resolution image of stars; in fact the NPOI gets such high resolution pictures, its main priority is discovering double stars or stars that rotate around each other. The capstone s contact and client, James Clark, has been working at the NPOI since 1990. James Clark has become concerned about the potential safety risks associated with removing the mirror caps. The mirrors aluminum coating is only a few molecules thick, so the mirrors need to be covered when not in use or the coating can be damaged by moisture or debris. Currently the mirrors are covered with a Lexan glass cylinder with a nitrogen purge. The Lexan glass protects the mirrors from debris and the nitrogen purge maintains 10 psi of pressure that prevents moisture from condensing on the mirror. This requires NPOI employees to crawl into each telescope, remove the mirror cap, and crawl out at 4 a.m. with no lights, this process can be very dangerous particularly in winter and is a major safety concern with the addition of 2 new taller telescopes. Needs Identification After reviewing the initial project outline presentation put together by our client, our group arranged a meeting with the client at the location this project will be deployed. Although the project outline stated the problem and requirements for our deliverable, our group was unclear on the actual incipience for our project's creation. Questions that we were particularly interested in having answered were: What is the intended use of our device? Who are the people this project affects most directly? What were the motivating factors for our client to seek NAU capstone as a solution venue? What was the physical environment our device would operate in? Had our client already given thought to possible solutions? While touring the facility grounds and being shown the physical locations of the project's environment, it became obvious to our group that the driving force for our project was the safety of the employees who interact with the current system. Although the automation of these mirror covers will eliminate unnecessary man hours; more importantly, the current system involves an unacceptable level of danger for the operators. Coupled with the possibility of damage to highly sensitive equipment that is put at risk with the current procedure, our needs statement is as follows: Needs Statement -Potential for injury to employees of the Navy Precision Optical Interferometer is unacceptable. 1 P a g e

Problem Statement Goal Statement A solution for removing and replacing essential mirror dust covers must be found while maintaining functionality of existing equipment, adding a minimum amount of mass to the system while incorporating autonomous/ semi-autonomous operation during power loss situations. Objectives The new cover must operate remotely, from outside of the equipment housing, keeping observers out of potential danger and protecting the equipment from accidental impacts. The mirror must be kept in a nitrogen environment in order to displace moisture. In order to do this, an orifice, 4 thousands of an inch in diameter must allow 10 psi of nitrogen to be injected through the mirror cover, purging atmospheric air. The nitrogen flow needs to automatically shut off when the cover is open. In addition, the equipment must maintain balance so that motor components are not exposed to excess stress during rotation. The new equipment should enhance the performance of the equipment that is in place and should in no way hinder the operations of the equipment. Constraints The cover must not block any light from the mirror s lens. The full range of motion of the siderostat must be maintained after installation of the automated cover. This includes a vertical tilt from -10 to 60 degrees and a horizontal pan of -60 to 60 degrees. The cover must be able to close in the event of a power failure. Test Environment Testing new designs at NPOI might jeopardize the equipment which is expensive and precise therefore a scale model of the housing will be constructed to provide a more appropriate test environment. The model will need to replicate the -10 to 60 range of motion of the siderostat to assure that our design does not hinder the movement of the mirror. The scale model will also assure that the mirror cover does not interfere with light collection while in the open position. The design is also required to operate between a temperature range of -20 F to 100 F. Critical components will be tested in an environment cooled by dry ice in order to replicate operational requirements. Large components will be tested during sufficiently cold nights. A comprehensive thermal analysis will supplement findings if negative 20 degrees is not reached. The design will be tested with the nitrogen purge operating to assure the design does not restrict the flow of the inert gas protecting the siderostat. NPOI will provide the compressed nitrogen for this test. Recapitulation of Problem Statement An automatic mirror cover is needed at NPOI and must operate without interfering with current equipment while maintaining a nitrogen purge. 2 P a g e

Quality Function Diagram Development with House of Quality Figure 1 is a Quality Function Diagram; this figure shows how qualitative requirements can be quantified into a list of product features. Figure 1- Quality Function Diagram Figure 2 is a House of Quality; this figure demonstrates the relationships between different product features. Figure 2-House of Quality, the + symbol represent a positive correlation, the symbol represents a negative correlation. 3 P a g e

Project Plan Gantt Chart 4 P a g e

References Navy Precision Optical Interferometer. "Automated Mirror Cover for Telescope Application." Navy Precision Optical Interferometer. Powerpoint. 5 Oct. 2012. <https://bblearn.nau.edu/>. Navy Precision Optical Interferometer. Navy Precision Optical Interferometer, n.d. Web. 5 Oct. 2012. <http://www.lowell.edu/npoi/index.php>. 5 P a g e