Getting Started GUIDE LEAVE A LEGACY OF EXCELLENT OUTCOMES FOR PATIENTS WITH ASTIGMATISM. TECNIS TORIC 1-PIECE IOL pg 1

Similar documents
Ophthalmology Clinical Pearls A Quick Guide To Crystalens

LENS EXCHANGE WITH IMPLANTATION OF A BITORIC INTRAOCULAR LENS IN EYES WITH SIGNIFICANT ASTIGMATISM AFTER PREVIOUS CORNEAL SURGERIES

In November 1998, the Staar AA4203 toric intraocular. Early rotational stability of the longer Staar toric intraocular lens. Fifty consecutive cases

International Council of Ophthalmology s Ophthalmology Surgical Competency Assessment Rubric (ICO-OSCAR) ICO-OSCAR Instructor Directions

Injector system for implantation of 1stQ foldable intraocular lenses

Biometry tips. Marilyn Watkins-Ramdin, COMT ROUB

LENSTAR LS 900 Setting the standard in optical biometry

EVERY TREATMENT IS A TRUE ORIGINAL

Fitting Guide. Minutes-to-Fit 2.0. by SynergEyes Moving Vision Forward

Scleral Fitting Guide

INTRASTROMAL CORRECTION OF PRESBYOPIA AND CLINICAL APPLICATION WITH TECHNOLAS FEMTOSECOND LASER

Basic Concept & Techniques of Phaco Prechop

Sofmed breathables XW (comfilcon A) Sofmed breathables XW premium (comfilcon A) Sofmed breathables XW toric (comfilcon A)

OPESAVER Super Irrigation System

POLYMACON HYDROPHILIC CONTACT LENSES PRACTITIONER FITTING GUIDE

THE TOP 100 KEYWORDS FOR AN

25+ instruments answer the most common barrier to 25G instrument flexibility.

LASIK Wavefront Guided idesign LASIK with IntraLase

Andre Litwin BM FRCOphth Consultant Ophthalmologist and Oculoplastic Surgeon

Acknowledgments. Paragon Vision Sciences Adoption of CRT certification slide for this generic talk. Material Considerations

ASICO Innovative I/A Tip System (Patented) Maximize your I/A efficiency for Today s MICS and FLACS procedure

Insert to. Sponsored by Alcon Laboratories, Inc. February 2014 EXPLORING THE CATARACT REFRACTIVE SUITE FEATURING. The CENTURION Vision System

Financial Disclosures Toric IOL Selec-on and Posi-oning

Orthokeratology. What is Orthokeratology? How does it work?

Manual Small Incision Cataract Surgery

Appendix C: Skill Stations Examination - Marking Rubric

Learn Connect Succeed. JCAHPO Regional Meetings 2017

How images are formed in the eye

PACKAGE INSERT RIGID GAS PERMEABLE CONTACT LENSES FOR ORTHOKERATOLOGY. (hexafocon B)

Dr. Thomas R. Reim President, DreimLens, Inc.

Appendix C: Skill Stations Examination - Marking Rubric

Triple EK/CE/IOL has a cataract needs both DMEK and CEIOL

International Council of Ophthalmology s Ophthalmology Surgical Competency Assessment Rubric (ICO-OSCAR)

Pre- and postoperative refraction after cataract extraction with implantation of standard power IOL

CLINICAL SCIENCES. Michael Goggin, FRCSI(Ophth), MS; Sacha Moore, FRCOphth; Adrian Esterman, AStat, PhD

Management of corneal wounds: some practical tips. Lee SH, MD, FRCS (C ), FAAO

Eye Floaters Rhode Island Keyword Search Report

Eye Floaters Indiana Keyword Search Report

BIORAPTOR Knotless Suture Anchor Arthroscopic Shoulder Instability Repair. Shoulder Series Technique Guide by: Thomas Youm, MD

12.15 CORNEAL REFRACTIVE SURGERY (PRK/LASEK/LASIK/SMILE)

Eye Floaters Washington D.C. Keyword Search Report

VariSource High Dose Rate Afterloader Procedures. For Performing Breast Brachytherapy with. The SAVI TM Applicator

An introduction to modern scleral lenses

NAVAL SUBMARINE MEDICAL RESEARCH LABORATORY

Phacoemulsification and foldable posterior chamber intraocular lenses in aircrew: Clinical behaviour and aeromedical implications

Research Article Incidence and Outcomes of Anterior Chamber Gas Bubble during Femtosecond Flap Creation for Laser-Assisted In Situ Keratomileusis

The BE Retainer System Certification Course. Supplement

A life without glasses or contact lenses

FRA Spacer Instruments. For anterior lumbar interbody fusion (ALIF) using straight anterior or anterolateral approach.

CinchLock SS (Sports Sheath) Knotless Labrum Restoration SURGICAL TECHNIQUE

CATALOG CATALOG. Pioneer in Ophthalmic Products. BACK FLUSH INSTRUMENTS VITREORETINAL INSTRUMENTS

AIR OPTIX BRAND CONTACT LENSES LENS PARAMETER GUIDE November 2016

Pressure and Flow Characteristics of Ocular Viscoelastic and Silicone Oil Through Glaucoma Drainage Devices

Spherical Soft Contact Lens Fitting. J. Perrigin OPTO 6374 Spring 2017

Alberta Police Recruit Selection Standards

When evolution becomes

When evolution becomes

Eye Floaters Maine Keyword Search Report

Every challenge has a solution DePuy Spine, Inc. 325 Paramount Drive Raynham, MA USA Tel: +1 (800) SEAMLESS JUNCTIONAL CONNECTIONS

Training Guide STAR S4 IR Excimer Laser

Satisfaction. For you and your patients.

485 Annubar Primary Flow Element Installation Effects

Eye Injuries. Chapter 25

Ophthalmic Surgical Instruments

James T. Schwiegerling CURRICULUM VITAE

NormalEyes Guidelines For Successful Fitting RIGID GAS PERMEABLE SCLERAL CONTACT LENSES. Manufactured in Paragon HDS 1OO (paflufocon D)

DISCLOSURES FITTING AND TROUBLESHOOTING SCLERAL LENSES WHO S A GOOD CANDIDATE SCLERAL LENS ADVANTAGES ANDREW J. BIONDO, OD, FSLS.

Ophthalmic Surgical Instruments

FITTING AND TROUBLESHOOTING SCLERAL LENSES

10 Best Practices for Electrosurgical Unit Testing

TONOMETRY AND PACHYMETRY

MyoSure Tissue Removal System. For you and your patients.

Refraction Certificate Examination. Instructions to Candidates

Job Sheet 1 Blade Aerodynamics

Structural Design of Tank Weighing Systems

Density of Brass: Accuracy and Precision

Alternate Suction to Reduce Prolonged Air Leak

RECOMMENDER REQUIRED PRE-AUTH GROUP A PRE-AUTH GROUP B

TEST FOR STABILOMETER VALUE OF BITUMINOUS MIXTURES

VIC offers a variety of Calibrated Gas Leaks

Characterizers for control loops

Omega 3 Fatty Acid (O3FA) Bioabsorbable Coated Mesh

Gerald D. Anderson. Education Technical Specialist

Procedures for ETDRS 4M Refraction and Vision Testing. Katherine M. Burke, BS, CO, COMT CertifEYED Associates, LLC New York, New York

PROFESSIONAL FITTING GUIDE. for the. HUBBLE Daily. Table of Contents

Your new Keystone Telebinocular

V E J A R A N O P R O T O C O L FOR T H E M A N A G M E N T O F Q U E R A T O C O N O SURGICAL T I PS

Sizing Pulsation Dampeners Is Critical to Effectiveness

Implication of Multiple Leak Tests and Impact of Rest Time on Avionic Hybrids

senofilcon A Soft (hydrophilic) Contact Lenses Visibility Tinted with UV Blocker for Daily Disposable Wear

ROSE-HULMAN INSTITUTE OF TECHNOLOGY Department of Mechanical Engineering. Mini-project 3 Tennis ball launcher

Warnings: Notes: Revised: October 5, 2015

MET 335W Fluid Mechanics Laboratory. Lab 1: Bourdon Tube Calibration. Nick Peak

User s Guide. High Pressure NMR Cell. With High Pressure Tether. Bruker & Varian Cells TABLE OF CONTENTS:

PTFE-SINGLE GLASS FLOW METERS

Technical Note. Determining the surface tension of liquids by measurements on pendant drops

Sterile, Single-use, Instruments

Lab # 03: Visualization of Shock Waves by using Schlieren Technique

Lancets Recommended by PTS, Inc.

Road Force Elite The World s Fastest Diagnostic Balancer

Transcription:

Getting Started GUIDE LEAVE A LEGACY OF EXCELLENT OUTCOMES FOR PATIENTS WITH ASTIGMATISM. TECNIS TORIC 1-PIECE IOL pg 1

GETTING STARTED WITH THE TECNIS TORIC IOL The IOL you leave behind is the quality of vision your patients take with them. Use this guide to support optimal toric calculation and insertion, and leave a legacy of excellent outcomes for your patients with astigmatism. IN THIS GUIDE TECNIS TORIC IOL AT A GLANCE Designed for outstanding optical quality, the TECNIS Toric IOL delivers the sharpest vision, best low-light performance and long-term sustainability. 13.0 mm overall diameter LENS SPECIFICATIONS pg 3 TECNIS Toric IOL at a Glance CALCULATION pg 4 Calculate Proper Cylinder Power SURGERY pg 6 Pearls for Optimizing Toric IOL Outcomes PATIENT EDUCATION pg 8 Help Your Patients Understand the Benefits and Risks TECNIS IOL wavefront-designed toric aspheric surface Anterior cylinder axis marks denote IOL meridian with lowest power Frosted, continuous 360 posterior square edge Anterior Side Haptics offset for 3 points of fixation Posterior Side RESOURCES AND SUPPORT pg 9 Committed to Your Legacy 6.0 mm optic diameter TECHNICAL SPECIFICATIONS pg 10 INDICATIONS AND IMPORTANT SAFETY INFORMATION pg 11 INDICATIONS: The TECNIS Toric 1-Piece Posterior Chamber Lens is indicated for the visual correction of aphakia and pre-existing corneal astigmatism of one diopter or greater in adult patients with or without presbyopia in whom a cataractous lens has been removed by phacoemulsification and who desire improved uncorrected distance vision, reduction in residual refractive cylinder, and increased spectacle independence for distance vision. The device is intended to be placed in the capsular bag. See Important Safety Information on page 11. pg 2 TECNIS TORIC 1-PIECE IOL TECNIS TORIC 1-PIECE IOL pg 3

CALCULATION Calculate the Proper Cylinder Power for the TECNIS Toric IOL TECNIS TORIC IOL AT A GLANCE QUESTIONS & ANSWERS How is the cylinder calculated? Why is the sphere not displayed in the results section? The calculator uses the Holladay 1 formula for calculation of the cylinder. If you prefer to enter another IOL constant, the system will convert it. Why do I need to enter the axial length? As the sphere is calculated outside of the toric calculator, please refer to the printout of your biometry device. Why are three lens models displayed instead of the most suitable IOL model only? In contrast to other online calculators, the TECNIS Toric Calculator uses axial length for high accuracy of the calculation. 1 How does the TECNIS Toric Calculator compare to other online calculators? The choice of three IOLs should help to select the lens power that is most suitable for each individual patient. The calculator will provide options for the amount of residual cylinder based on your choice for an individualized patient outcome. This may include a choice of flipping the axis in order to achieve a lower amount of residual cylinder. Most toric calculators use an approximation method rather than the exact solution, using a constant for the ratio of the IOL toricity to corneal astigmatism. This approximation can cause errors. Please be aware that the more a patient s ocular parameters vary from normal, the more important it is to use the exact, rather than the approximation, solution used by other calculators. For instance, if the residual astigmatism does not change when the calculation is run for 10 D and 22 D IOLs, then the calculator is using the approximation method. 1 NOTE If you enter the K-readings in mm, the keratometer index is not used in the calculation; however, the TECNIS Toric Calculator requires that you select a value. Choose your preferred IOL constant and value Enter the spherical equivalent (as calculated with your biometry device) Reminder: How to print this page for surgical planning Make sure to select the correct corneal index for your keratometer if you have entered your K-readings in diopters Select the IOL model based on the residual cylinder and axis Preselect your preferred units: Format of date and decimal layout Select to display results as plus or minus cylinder Select K-notation input unit as diopters or millimeters How should I calculate SIA? Please refer to sia-calculator.com. If you enter the K-readings in diopters, the calculator requires and uses the appropriate keratometer index for the calculation. PRECAUTIONS: The use of methods other than the TECNIS Toric Calculator to select cylinder power and appropriate axis of implantation were not assessed in the clinical study and may not yield similar results. Accurate keratometry and biometry in addition to the use of the TECNIS Toric Calculator (www.tecnistoriccalc.com) are recommended to achieve optimal visual outcomes. The TECNIS Toric Calculator incorporates the surgeon s estimated SIA and incision location when providing IOL options. 1. Holladay JT. Improving toric IOL outcomes. Ocular Surgery News. May 25 and June 10, 2011. pg 4 TECNIS TORIC 1-PIECE IOL TECNIS TORIC 1-PIECE IOL pg 5

SURGERY Clinical Pearls for Optimizing Toric IOL Outcomes Provided by Daniel Chang, MD 1. CORNEAL MARKING Mark the steep corneal axis clearly and accurately In order to identify specific iris structures, reference the measured steep axis to a preoperative pupil image Under the guidance of a slit lamp or surgical microscope, place precise intrastromal arcuate incisions with a laser or mark the eye with ink 2. OPENING STEPS Ensure proper wound construction Whether using a femtosecond laser or a blade, construct a triplanar incision that will seal well at the end of a case Create a well-centered capsulotomy that can provide 360 of capsular overlap, which may help limit asymmetric capsular forces on the IOL postoperatively 3. IOL UNFOLDING AND POSITIONING Take time for optimal unfolding Prime the IOL injection cartridge and inflate the capsular bag using a cohesive viscoelastic Allow ample time for the IOL to unfold depending on OR temperature, this may take 30 40 seconds Rotate the IOL in the bag several times, even before unfolding is complete, to ensure the haptics are fully deployed into the capsular fornix and to help loosen any remaining cortical material Rotating the lens while it is unfolding eliminates the need to warm the IOL and/or OVD to facilitate faster unfolding, allowing you to utilize the time for proper positioning instead Occasionally, it may be necessary to assist the haptics in unfolding Scrape the posterior aspect of the anterior capsular rim to remove lens epithelial cells Though some surgeons suggest skipping this step to promote stability through adhesion of the capsule to the optic, this may result in capsular fibrosis due to retained lens epithelial cells Once the IOL has completely unfolded, align the marks on the IOL with the corneal marks placed on the steep meridian To help with centration and address the problem of parallax, have the patient fixate on a coaxial light source 4. OVD REMOVAL Completely remove OVD under the IOL To help remove the viscoelastic from the poster chamber and from behind the IOL, rotate the IOL and press slightly posteriorly while irrigating and aspirating As an extra step, place the I/A hand piece behind the IOL to ensure complete OVD removal 5. IOL AND WOUND CHECK Ensure optimal positioning and pressure After the IOL is rotated into position, lightly press it onto the posterior capsule to help hold it into position Perform initial wound hydration prior to final IOL positioning Once the lens in in position, take care not to induce any IOL movement during subsequent wound hydrations by applying only mild-to-moderate pressure when injecting To minimize intraocular turbulence or hyperinflation, inject tangentially to the wound Bring the eye to physiologic pressure, taking care not to hyperinflate Postoperative hypotony likely plays a major role in IOL rotation A hypotonous eye can compress easily with blinking or eye rubbing, and a gross deformation of the globe could cause a shift in IOL positions To maintain physiologic pressure, meticulously check the wounds for leakage When performing the check, dry the wound to find any slow leaks and press on the globe to simulate an eye rub When in doubt, do not hesitate to close the wound with a suture 6. FINAL CHECK OF LENS POSITIONING Secure IOL position for outstanding outcomes At the end of the case, check for any IOL movement by having the patient look up, down, left and right After removing the speculum and drape, perform a final check to ensure the IOL has not moved or shifted, ensuring the patient leaves the operating room with the IOL in an optimal position Place an eye shield and instruct the patient not to rub his or her eye after surgery AMO does not engage in the practice of medicine, and Dr. Chang s clinical tips are not a substitute for appropriate medical education and training or for the exercise of independent medical judgment. AMO cannot warrant the accuracy or completeness of information contained within this document. AMO does not endorse or recommend any particular technique beyond what is contained in the product labeling, and other techniques may be appropriate in a physician s medical judgment. pg 6 TECNIS TORIC 1-PIECE IOL TECNIS TORIC 1-PIECE IOL pg 7

PATIENT EDUCATION Help Your Patients Understand the Benefits and Risks of a TECNIS Toric 1-Piece IOL RESOURCES AND SUPPORT Committed To Your Legacy Tell your patients about the convenience of one procedure to both eliminate their cataracts and correct their astigmatism Explain to your patients that careful calculations have been performed to choose the optimal lens power for their eye, but: - They may still need glasses for reading and distance vision after surgery - In rare cases, the lens might change its position after surgery and a second intervention might be needed for realignment - In case of increasing blurred vision after surgery, they need to contact you or at least let the referring doctor know that they have received a toric lens SIMULATED VISION Cataracts and astigmatism create cloudy and blurred vision. Even after the cataract is removed, the astigmatism will still cause blurred vision. VISIT TECNISIOL.COM FOR ADDITIONAL RESOURCES Optimizing Toric IOL Outcomes video with Daniel Chang, MD Toric calculator Vision simulator Brochure Spec sheet Directions for use Promotional tools For support, contact your Abbott representative or call 1-800-366-6554. ATTENTION: Reference the Directions for Use for a complete listing of indications, warnings, precautions and safety information. Explain the potential risks of cataract surgery and lens replacement, including worsening of vision, bleeding or infection Let your patients know they should contact you if they experience itching, redness, pain, floaters, flashing lights, severe headache, light sensitivity or watery eyes after the surgery Tell your patients the side effects specific to the TECNIS Toric Lens, including the potential need for secondary surgical intervention to replace the lens or repair the eye, macular edema and retinal detachment With the TECNIS Toric IOL, you may have less dependence on glasses for distance vision. pg 8 TECNIS TORIC 1-PIECE IOL TECNIS TORIC 1-PIECE IOL pg 9

TECHNICAL SPECIFICATIONS TECNIS Toric Aspheric IOL Specifications Powers +5.0 D to +34.0 D in 0.5 diopter increments Cylinder Powers 1.50 D, 2.25 D, 3.00 D, 4.00 D, 4.50 D, 5.25 D, 6.00 D Diameter 6.0 mm Optic Overall Length 13.0 mm Shape Biconvex, anterior toric aspheric surface Material UV-blocking hydrophobic acrylic Refractive Index 1.47 INDICATIONS AND IMPORTANT SAFETY INFORMATION FOR THE TECNIS TORIC 1-PIECE IOL CAUTION: Federal law restricts this device to sale by or on the order of a physician. INDICATIONS: The TECNIS Toric 1-Piece Posterior Chamber Lens is indicated for the visual correction of aphakia and pre-existing corneal astigmatism of one diopter or greater in adult patients with or without presbyopia in whom a cataractous lens has been removed by phacoemulsification and who desire improved uncorrected distance vision, reduction in residual refractive cylinder, and increased spectacle independence for distance vision. The device is intended to be placed in the capsular bag. WARNINGS: Physicians considering lens implantation should weigh the potential risk/benefit ratio for any circumstances described in the TECNIS Toric 1-Piece IOL Directions for Use that could increase complications or impact patient outcomes. The clinical study did not show evidence of effectiveness for the treatment of preoperative corneal astigmatism of less than one diopter. The TECNIS Toric 1-Piece IOL should not be placed in the ciliary sulcus. Rotation of the TECNIS Toric 1-Piece IOL away from its intended axis can reduce its astigmatic correction. Misalignment greater than 30 may increase postoperative refractive cylinder. Edge Design Haptic Design A-constants ProTEC continuous 360 posterior, frosted square edge Offset from optic with 3-point fixation 119.3* (Optical Biometry) 118.8 (Ultrasound Biometry) PRECAUTIONS: Accurate keratometry and biometry in addition to the use of the TECNIS Toric Calculator (www.tecnistoriccalc.com) are recommended to achieve optimal visual outcomes. The safety and effectiveness of the toric intraocular lens have not been substantiated in patients with certain preexisting ocular conditions and intraoperative complications. Refer to the TECNIS Toric 1-Piece IOL Directions for Use for a complete description of the preexisting conditions and intraoperative complications. All preoperative surgical parameters are important when choosing a toric lens for implantation. Variability in any of the preoperative measurements can influence patient outcomes. All corneal incisions were placed temporally in the clinical study. Do not reuse, resterilize, or autoclave. *Derived from clinical evaluation results of the TECNIS 1-Piece Platform. Value theoretically derived for a typical 20.0 D lens. Abbott Medical Optics recommends that surgeons personalize their A-constant based on their surgical techniques and equipment, experience with the lens model and postoperative results. ADVERSE EVENTS: The most frequently reported cumulative adverse event that occurred during the TECNIS Toric 1-Piece IOL clinical trial was surgical re-intervention which occurred at a rate of 3.4% (lens repositioning procedures and retinal repair procedures). Cylinder Power Options Lens Model ZCT150 ZCT225 ZCT300 ZCT400 ZCT450 ZCT525 ZCT600 Cylinder Powers IOL Plane 1.50 D 2.25 D 3.00 D 4.00 D 4.50 D 5.25 D 6.00 D Corneal Plane* 1.03 D 1.54 D 2.06 D 2.74 D 3.08 D 3.60 D 4.11 D Corneal Astigmatism Correction Range (Preop Kcyl+SIA) 0.75 1.50 D 1.50 2.00 D 2.00 2.75 D 2.75 3.62 D 3.00 3.50 D 3.50 4.00 D 4.00 4.75 D *Based on average pseudophakic human eye. Based on a vector sum of preoperative corneal astigmatism (preop Kcyl) and the predicted effect of surgically induced astigmatism (SIA). pg 10 TECNIS TORIC 1-PIECE IOL TECNIS TORIC 1-PIECE IOL pg 11

TECNIS and ProTEC are trademarks owned by or licensed to Abbott Laboratories, its subsidiaries, or affiliates. All other trademarks and tradenames are the intellectual property of their respective owners. 2015 Abbott Medical Optics Inc. www.abbottmedicaloptics.com PP2015CT0789 Reorder: TEC15-19