CVS10 Sanitary Check Valves

Similar documents
DCV10 Stainless Steel Disc Check Valve for use with Condensate Pumps

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

DCV1, DCV3 and DCV3LT Disc Check Valves Installation and Maintenance Instructions

DCV6 Disc Check Valve

CS10-1 Stainless Steel Clean Steam Separator

TSS21 Sealed Thermostatic Steam Tracer Trap

DF1 and DF2 Diffusers

AVM7 Stainless Steel Thermostatic Air Vent

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

AVC32 Carbon Steel Air Vent for Steam Systems

AE14 Automatic Air Vents for Liquid Systems Installation and Maintenance Instructions

BTM7, BTS7 and BTS7.1 Stainless Steel Thermostatic Clean Steam Traps

TP1 and TP2 Temporary Cone Shaped Strainers

BT6-B Sanitary Balanced Pressure Thermostatic Steam Trap

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

Fig 12, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators

PV4 and PV6 Piston Valves

Fig 1, Fig 12, Fig 13, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

TA10A and TA10P Steam Tracing Temperature Control Valves Installation and Maintenance Instructions

AE30 Automatic Air Eliminators / Air and Gas Vents for Liquid Systems

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

CA44, CA44S, CA46 and CA46S Air and Gas Traps

Dri-Line Mk3 Monnier Compressed Air Drain Trap

CP10 Sensor Installation and Maintenance Instructions

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

IFTGS14 Ball Float Steam Trap ½" and ¾" with Integral Spiratec Sensor

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators Installation and Maintenance Instructions

FTGS14 Ball Float Steam Trap DN15 (½") to DN25 (1")

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

SRV66 Sanitary Pressure Reducing Valve

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Knob Adjustment)

BPT13 Balanced Pressure Thermostatic Steam Traps

M70i ISO and M80i ISO Stainless Steel Ball Valves for Sanitary Systems Installation and Maintenance Instructions

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Dial Adjustment)

Airodyn, BRair and BRoil Compressed Air Drain Traps

Fig 3, 7, 33, 34, 34HP, 36, 36HP, 37, 3616 and Fig 3716 Flanged Strainers

FV Flash Vessel Installation and Maintenance Instructions

M10HTi ISO Tobacco Ball Valve Screwed, SW, BW and Flanged versions

MF2M Monnier Miniature Compressed Air Filter

S and SF Inverted Bucket Steam Traps

PC10HP Pipeline Connector (ASME 600)

M33F ISO, M33S ISO and M33V ISO Ball Valves Installation and Maintenance Instructions

Manual Actuated Boiler Blowdown Valves

IX1 Spirax-Monnier International Compressed Air Filter Installation and Maintenance Instructions

TDC46M, TDS46M and UTDS46M Thermodynamic Steam Traps with Maintainable Seat Installation and Maintenance Instructions

APT14, APT14HC and APT14SHC Spares 2

MFP14-PPU (Vented) Automatic Packaged Pump Units

Fig 7, 33, 33.1, 34, 34HP, 36, 36HP, 37, 3616 and Fig 3716 Flanged Strainers Installation and Maintenance Instructions

TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats

TW Temperature Control Valve

CA16 and CA16S-14 Air and Gas trap Installation and Maintenance Instructions

ML3M Monnier Miniature Compressed Air Lubricator

Spirax Compact FREME Flash Recovery Energy Management Equipment

STERI-TROL Clean Service 'S' Series Two-port Control Valves DN15 (½") to DN100 (4")

1. General safety information. 2. General product information. 3. Installation. 4. Commissioning. 5. Operation. 6. Maintenance. 7.

FT53, IFT53, FT54, IFT54, FT57 and IFT57 Ball Float Steam Traps - DIN

CA10S, CA14 and CA14S Air and Gas Traps

TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats Installation and Maintenance Instructions

AVS32 Stainless Steel Air Vent for Steam Systems Installation and Maintenance Instructions

BDV1 and BDV2 Blowdown / Depressurisation Valves

SA Control Valve types: BM, BMF, BX, SB, NS, KA, KB, KC (Normally open) BMRA, BMFRA, BXRA, SBRA, NSRA, KX, KY (Normally closed)

SCA Series Inverted Bucket Steam Traps

BCV31 DN40 - Blowdown Control Valve

AE50S Automatic Air and Gas Vent for Liquid Systems Installation and Maintenance Instructions

Type 130 and HL10 'Safeguard High Limit Control' Installation and Maintenance Instructions

Spirax SafeBloc TM DBB3 Double Block and Bleed Bellows Sealed Stop Valve. 1. Safety information. 2. General product information. 3.

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

BRV71 and BRV73 Pressure Reducing Valves

SRV2S Pressure Reducing Valve

BTD52L Thermodynamic Steam Trap Installation and Maintenance Instructions

BCV31 DN20 - Blowdown Control Valve

UBP32 Sealed Balanced Pressure Thermostatic Steam Trap for use with PC_ Pipeline Connectors Installation and Maintenance Instructions

MPC1M, MPC2M and MPC2AM Monnier High Efficiency Compressed Air Filter / Regulators

BSA6T and BSA64T Stainless Steel Bellows Sealed Stop Valves Installation and Maintenance Instructions

FT16 Ball Float Steam Trap Installation and Maintenance Instructions

SRV461S and SRV463S Stainless Steel Direct Acting Pressure Reducing Valves

Thermocirc Installation and Maintenance Instructions

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions

Vane Flow Switches Colima FLU Series

QuickHeat TM Packaged Heat Exchanger Solutions

A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

TD10, TD52M and TD259 Thermodynamic Steam Traps Installation and Maintenance Instructions

FT43, FT44, FT46 and FT47 Ball Float Steam Traps Installation and Maintenance Instructions

Fig 1, Fig 12, Fig 13, Fig 14, Fig 16 and Fig 16L Strainers Installation and Maintenance Instructions

FTC62 and FTS62 Ball Float Steam Traps Installation and Maintenance Instructions

M111 Spiraflo Transducer

BCVi43 Blowdown Control Valve

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

BSA and BSAT Bellows Sealed Stop Valves Installation and Maintenance Instructions

PC3000, PC3001 and PC4000, PC4001 Pipeline Connectors

LP31 Level Probe. 1. Safety information. 2. General product information. 3. Installation. 4. Wiring. 5. Maintenance

Colima TOR Magnetic Level Switches

BDV60 Blowdown Vessel Installation and Maintenance Instructions

595-K/L and 596-K/L Series Self Operated Valves Installation and Maintenance Instructions

RJ check valves Installation and Maintenance Instructions

Transcription:

0299050/4 IM-P029-11 ST Issue 4 CVS10 Sanitary Check Valves Installation and Maintenance Instructions 1. Safety information CVS10 with soft seat 2. General product information 3. Operation 4. Installation CVS10 with 5. Commissioning 6. Spare parts and Maintenance IM-P029-11 Printed in the ST UK Issue 4 Copyright 20111

1. Safety information Safe operation of this product can only be guaranteed if it is properly installed, commissioned, used and maintained by qualified personnel (see Section 1.11) in compliance with the operating instructions. General installation and safety instructions for pipeline and plant construction, as well as the proper use of tools and safety equipment must also be complied with. 1.1 Intended use Referring to the Installation and Maintenance Instructions, body markings and Technical Information Sheet, check that the product is suitable for the intended use/application. The product listed below complies with the requirements of the European Pressure Equipment Directive 97/ 23 / EC and carries the mark when so required. It should be noted that products rated as 'SEP' are required by the Directive not to carry the mark. The product falls within the following Pressure Equipment Directive categories: Product Process gases Process fluids Group 1 Group 2 Group 1 Group 2 CVS10 sanitary check valve - SEP - SEP i) The CVS10 has been specifically designed for use on steam, process fluids, process gases or water / condensate which are in Group 2 of the above mentioned Pressure Equipment Directive. The products' use on other fluids may be possible but, if this is contemplated, Spirax Sarco should be contacted to confirm the suitability of the product for the application being considered. ii) Check material suitability, pressure and temperature and their maximum and minimum values. If the maximum operating limits of the product are lower than those of the system in which it is being fitted, or if malfunction of the product could result in a dangerous overpressure or overtemperature occurrence, ensure a safety device is included in the system to prevent such over. iii) Determine the correct installation situation and direction of fluid flow. For applications that are self-draining they must be with the flow vertically downwards. iv) Spirax Sarco products are not intended to withstand external stresses that may be induced by any system to which they are fitted. It is the responsibility of the installer to consider these stresses and take adequate precautions to minimise them. v) Remove protective covers from all connections and protective film from all name-plates,where appropriate, before installation on steam or other high temperature applications. 2 IM-P029-11 ST Issue 4

1.2 Access Ensure safe access and if necessary a safe working platform (suitably guarded) before attempting to work on the product. Arrange suitable lifting gear if required. 1.3 Lighting Ensure adequate lighting, particularly where detailed or intricate work is required. 1.4 Hazardous liquids or gases in the pipeline Consider what is in the pipeline or what may have been in the pipeline at some previous time. Consider: flammable materials, substances hazardous to health, extremes of temperature. 1.5 Hazardous environment around the product Consider: explosion risk areas, lack of oxygen (e.g. tanks, pits), dangerous gases, extremes of temperature, hot surfaces, fire hazard (e.g. during welding), excessive noise, moving machinery. 1.6 The system Consider the effect on the complete system of the work proposed. Will any proposed action (e.g. closing isolation valves, electrical isolation) put any other part of the system or any personnel at risk? Dangers might include isolation of vents or protective devices or the rendering ineffective of controls or alarms. Ensure isolation valves are turned on and off in a gradual way to avoid system shocks. 1.7 Pressure systems Ensure that any pressure is isolated and safely vented to atmospheric pressure. Consider double isolation (double block and bleed) and the locking or labelling of closed valves. Do not assume that the system has depressurised even when the pressure gauge indicates zero. 1.8 Temperature Allow time for temperature to normalise after isolation to avoid the danger of burns and consider whether protective clothing (including saftey glasses) is required. Viton body seal If the Viton components have been subjected to a temperature approaching 315 C (599 F) or higher they may have decomposed and formed hydroflouric acid. Avoid skin contact and inhalation of any fumes as the acid will cause deep skin burns and damage the respitory system. 1.9 Tools and consumables Before starting work ensure that you have suitable tools and / or consumables available. Use only genuine Spirax Sarco replacement parts. 1.10 Protective clothing Consider whether you and / or others in the vicinity require any protective clothing to protect against the hazards of, for example, chemicals, high / low temperature, radiation, noise, falling objects, and dangers to eyes and face. IM-P029-11 ST Issue 4 3

1.11 Permits to work All work must be carried out or be supervised by a suitably competent person. Installation and operating personnel should be trained in the correct use of the product according to the Installation and Maintenance Instructions. Where a formal permit to work system is in force it must be complied with. Where there is no such system, it is recommended that a responsible person should know what work is going on and, where necessary, arrange to have an assistant whose primary responsibility is safety. Post warning notices if necessary. 1.12 Handling Manual handling of large and / or heavy products may present a risk of injury. Lifting, pushing, pulling, carrying or supporting a load by bodily force can cause injury particularly to the back. You are advised to assess the risks taking into account the task, the individual, the load and the working environment and use the appropriate handling method depending on the circumstances of the work being done. 1.13 Residual hazards In normal use the external surface of the product may be very hot. If used at the maximum permitted operating conditions the surface temperature of some products will exceed temperatures of 100 C (212 F). Many products are not self-draining. Take due care when dismantling or removing the product from an installation (refer to Maintenance instructions ). 1.14 Freezing Provision must be made to protect products which are not self-draining against frost damage in environments where they may be exposed to temperatures below freezing point. 1.15 Disposal The product is recyclable. No ecological hazard is anticipated with the disposal of this product providing due care is taken, EXCEPT: Viton body seal: - In compliance with National and Local regulations waste parts can be landfilled. - Waste parts can be incinerated, but a scrubber must be used to remove Hydrogen Fluoride, which is evolved from the product and with compliance to National and Local regulations. - Is insoluble in acquatic media. 1.16 Returning products Customers and stockists are reminded that under EC Health, Safety and Environment Law, when returning products to Spirax Sarco they must provide information on any hazards and the precautions to be taken due to contamination residues or mechanical damage which may present a health, safety or environmental risk. This information must be provided in writing including Health and Safety data sheets relating to any substances identified as hazardous or potentially hazardous. 4 IM-P029-11 ST Issue 4

2. General product information 2.1 Description The CVS10 sanitary in-line spring assisted check valve range are manufactured from 316L stainless steel and prevent reverse flow in fluid lines. They are available with either soft seats for process gasses and liquids, or with a for use within steam systems. They are suitable for a wide range of high purity applications in the food, medical, and pharmaceutical industries. For use with other medium please consult Spirax Sarco. Available types and surface finish: CVS10-1_ has an internal surface finish of 0.5 micron Ra (within ASME BPE SF1), and external surface finish of 0.8 micron Ra. CVS10-2_ has an electropolished internal surface finish of 0.38 Ra (within ASME BPE SF4), and external surface finish of 0.8 micron Ra. In addition both the CVS10-1 and CVS10-2 are available with either EPDM, Viton or FEP-Silicone soft seats for process gasses and liquids, or with a for use within steam systems. The soft seated models have a suffix to denote which seat is fitted: 'E' for EPDM, 'F' for FEP-Silicone or 'V' for Viton. For example, the model reference CVS10-2E denotes a CVS10 with electropolished internal finish and EPDM soft seat. Standards: - The CVS10 fully complies with the European Pressure Equipment Directive 97 / 23 / EC. - All wetted elastomers / polymers comply with FDA regulation CFR 21, paragraph 177, section 2600 for EPDM and Viton and section 1550 for FEP-Silicone and TFM PTFE. - The CVS10 is designed in accordance with ASME-BPE. Certification This product is available with the following certification: - EN 10204 3.1 material certification as standard. - Typical surface finish certificates. - FDA approval certificates for elastomers. - USP class VI approval certificates. - ADI free certificate. Note: All certification / inspection requirements must be stated at the time of order placement. Packaging Packaging for this product is conducted in a clean environment, segregated from other non stainless steel products, and in accordance with the current edition of ASME BPE. Inlet and outlet connections are capped and the product is sealed in a plastic bag prior to boxing. Note: For further information see the following Technical Information sheets: TI-P029-10 for the CVS10 with soft seat or TI-P029-21 for the CVS10 with. 2.2 Sizes and pipe connections ½", ¾", 1", 1½" and 2" to ASME BPE available as standard. DN15 to DN50 to DIN 32676 available as standard. Sanitary clamp: - ASME BPE clamp. - Sanitary clamp to DIN 32676. Note: Alternative connections and sizes are available on request. Fig. 1 CVS10 with and sanitary clamp IM-P029-11 ST Issue 4 5

2.3 Pressure / temperature limits CVS10 with soft seat CVS10 with Temperature C Temperature C Pressure psi g 0 200 25 50 75 100 125 150 100 50 0 0 2 4 6 8 Pressure bar g Pressure psi g 0 25 50 75 100 125 220 200 150 100 50 0 0 Steam saturation curve 2 4 6 8 10 Pressure bar g 10 300 200 100 400 300 200 100 Temperature F Temperature F The CVS10 with EPDM seats must not be used in this region. Body design conditions PN10 CVS10 Viton 10 bar g @ 200 C (145 psi g @ 392 F) PMA Maximum allowable with FEP-Silicone 10 bar g @ 200 C (145 psi g @ 392 F) soft seat EPDM 10 bar g @ 150 C (145 psi g @ 302 F) pressure CVS10 with 10 bar g @ 220 C (145 psi g @ 428 F) CVS10 Viton 200 C @ 10 bar g (392 F @ 145 psi g) TMA Maximum allowable with FEP-Silicone 200 C @ 10 bar g (392 F @ 145 psi g) soft seat EPDM 150 C @ 10 bar g (302 F @ 145 psi g) temperature CVS10 with 220 C @ 10 bar g (428 F @ 145 psi g) Minimum allowable CVS10 with soft seat -20 C (-4 F) temperature CVS10 with -254 C (-435 F) PMO Maximum operating pressure for saturated steam service 10 bar g (145 psi g) CVS10 Viton 200 C @ 10 bar g (392 F @ 145 psi g) TMO Maximum operating with FEP-Silicone 200 C @ 10 bar g (392 F @ 145 psi g) soft seat EPDM 150 C @ 10 bar g (302 F @ 145 psi g) temperature CVS10 with 220 C @ 10 bar g (428 F @ 145 psi g) Minimum operating temperature 0 C (32 F) Designed for a maximum cold hydraulic test pressure of: 15 bar g (217 psi g) 6 IM-P029-11 ST Issue 4

3. Operation The valve is opened by the pressure of the fluid (Figure 2). When fluid flow stops the spring closes the valve before reverse flow can occur (Figure 3). Fig. 2 Fig. 3 3.1 Opening pressures Differential pressure with zero flow in mbar Soft seated versions Size ½" ¾" 1" 1½" 2" 35 35 35 35 35 39 39 41 43 43 31 31 29 27 27 Metal seated versions Size ½" ¾" 1" 1½" 2" 35 35 35 35 35 39 39 39 39 39 31 31 31 31 31 Flow direction Flow direction 3.2 Kv values For conversation: C v (UK) = Kv x 0.963 C v (US) = K v x 1.156 Size ½" ¾" 1" 1½" 2" CVS10 with soft seat 8.2 8.2 17.3 27.3 40.5 CVS10 with 2.0 2.0 4.0 8.0 18.0 4. Installation Before actioning any installation, observe the Safety information in Section 1. Referring to the Installation and Maintenance Instructions, body markings and Technical Information Sheet, check that the product is suitable for the intended installation: 4.1 Check materials, pressure and temperature and their maximum values. If the maximum operating limit of the product is lower than that of the system in which it is being fitted, ensure that a safety device is included in the system to prevent overpressurisation. 4.2 Determine the correct installation situation and the direction of flow. 4.3 Remove protective covers from all connections and protective film from all nameplates, where appropriate, before installation on steam or other high temperature applications. 4.4 The CVS10 can be fitted in both horizontal and vertical lines. For applications that are self-draining it must be installed in such a way that the flow is vertical downwards. 4.5 Fittings, clamps and gaskets for the connecting tubing are not supplied. Note: This product must be handled carefully to ensure that the surface finish is not damaged. IM-P029-11 ST Issue 4 7

5. Commissioning After installation or maintenance ensure that the system is fully functioning. Carry out tests on any alarms or protective devices. Note: If installed on a steam / condensate system, it is very important that the pressure is built up slowly to avoid possible damage to the unit. 6. Spare parts and Maintenance Note: Before actioning any maintenance, observe the 'Safety information' in Section 1 Before undertaking any maintenance on this product, it must be isolated from the supply and return lines and any pressure allowed to normalise to atmosphere. The unit should then be allowed to cool. 6.1 Spare parts The CVS10 sanitary in-line spring assisted check valve range are manufactured from 316L stainless steel and prevent reverse flow in fluid lines. They are available with either soft seats for process gasses and liquids, or with a for use within steam systems. They are suitable for a wide range of high purity applications in the food, medical, and biopharmaceutical industries. For use with other medium please consult Spirax Sarco. Note: The CVS10-1 with and CVS10-2 with are non maintainable - There are no spare parts available. Available spares Seal kit 4 and 7 How to order spares Always order spares by using the description given in the column headed 'Available spares' and state the size and type of check valve. Example: 1 off Seal kit for a 1" Spirax Sarco CVS10-1E sanitary check valve with EPDM seat having ASME BPE clamp ends. 8 1 4 3 5 7 6 7 2 6.2 How to renew the internals - Soft seated versions only: - Ensure that the system has cooled and any system pressure has been relieved before dismantling the product. Fig. 4 CVS10-1E with soft seat and sanitary clamp - Dismantle the inlet and outlet connectors and remove the complete valve from the system. - Remove the central body clamp fitting (8) and seperate the two parts of the check valve (1 and 2) - Remove the valve head (3) and spring (5) and then remove the valve seat (4) from the valve head (3). Replace the valve seat (4) with a new one making sure it is not damaged during the process. - Remove the valve guide and bush (6) and clean if required. - Assemble the valve head (3) (including seal (4)) and spring (5) into the valve guide (6) and place in the body (2). - Replace all body seals (7) and then replace the body clamp (8) and tighten. 8 IM-P029-11 ST Issue 4