Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

Similar documents
Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Steam Trap BK BK 212-ASME. Original Installation Instructions English

UNA 45 UNA 46 UNA 46A

Steam Trap BK 15 (DN40, DN 50) Original Installation Instructions English

GESTRA Steam Systems AK 45. Installation Instructions Condensate Drain Valve AK 45

Steam Trap MK 25/2 MK 25/2S

Steam trap BK 37 BK 28 BK 29 BK 37 ASME BK 28 ASME BK 29 ASME

SCA Series Inverted Bucket Steam Traps

Inverted Bucket Steam Trap IB 16A-7

AK 45. Installation Instructions Condensate Drain Valve AK 45. A Siebe Group Product 1

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

GESTRA Steam Systems BK 45 BK 45U BK 46. English. Installation Instructions Steam Traps BK 45, BK 45U, BK 46

AVS32 Stainless Steel Air Vent for Steam Systems Installation and Maintenance Instructions

Control Valve with ZK Radial Stage Nozzle ZK 210. Original Installation Instructions English

Series 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version

Non-Return Valve SRK 22A

Si C132. Safety valves for pressure relief in accordance to PED, DIN/EN and ASME. Engineering GREAT Solutions

FT16 Ball Float Steam Trap Installation and Maintenance Instructions

Pressure Reducing Valve for Steam Type 2333 A

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

TSS21 Sealed Thermostatic Steam Tracer Trap

FTGS14 Ball Float Steam Trap DN15 (½") to DN25 (1")

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

Swing Check Valve CB 14 CB 24S CB 26 CB 26A

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

MAKING MODERN LIVING POSSIBLE. Pilot operated internal safety valves type POV REFRIGERATION AND AIR CONDITIONING DIVISION.

756 Safety Relief Valves

AE50S Automatic Air and Gas Vent for Liquid Systems Installation and Maintenance Instructions

CA46S Austenitic Stainless Steel Air and Gas Trap DN40 and DN50

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL PRV44

UBP32 Sealed Balanced Pressure Thermostatic Steam Trap for use with PC_ Pipeline Connectors Installation and Maintenance Instructions

BTM7, BTS7 and BTS7.1 Stainless Steel Thermostatic Clean Steam Traps

776 Cryogenic Safety Valve

Serie 06-M6. Swing wafer check valve. made in. Application fields. Check valves E U R O P E WATER CONDITIONING INDUSTRY

A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions

Eaton Filtration, LLC

Pressure reducing valves Index

PV4 and PV6 Piston Valves

COMMITTEE DRAFT. API 520 Part I 10 th Edition Ballot Item 2.1. This ballot covers the following item:

Regulating valves Type REG 6-65 Type REG-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Production capacity.

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

T 2523 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators ANSI version

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

Solenoid valves, two-step on/off Type PMLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

CAST IRON SAFETY VALVE TYPE 6301

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve. ANSI version

6301 TYPE CAST IRON SAFETY VALVES

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

Pressure Reducing Valves Pressure Reducing with. Broady Flow Control. C Series Range. Pressure Reducing Valves. Broady Flow Control

Regulating valves REG-SA and REG-SB

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

CA44 and CA44S Carbon Steel Air and Gas Traps Flanged DN15 to DN25

Technical Data Sheet T 2025

Technical data. Back pressure limit: 27.5% of set pressure. Capacity certification: ASME Boiler & Pressure Vessel Code Section I and VIII

A soft sealed atmospheric safety valve with large flow capacity and soft seat tightness for steam condenser and turbine applications

PRESSURE REDUCING VALVE RP45 (EN)

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions

S and SF Inverted Bucket Steam Traps

3-way control valves VK 3

CA16 and CA16S-14 Air and Gas trap Installation and Maintenance Instructions

Safety relief valves, type BSV 8 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

BDV1 and BDV2 Blowdown / Depressurisation Valves

AVM7 Stainless Steel Thermostatic Air Vent

Self-operated Pressure Regulators Type Universal Pressure Reducing Valve

2-step solenoid valve Type ICLX

Solenoid Valves, one - or two step, on/off ICLX

2-step solenoid valve Type ICLX

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

CA10S, CA14 and CA14S Air and Gas Traps

2 - way valve (NO) for steam, pressure relieved (PN 25) VGS - external thread

IFTGS14 Ball Float Steam Trap ½" and ¾" with Integral Spiratec Sensor

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

SPECIFICATION // DATA SHEET WATER DRAIN VALVE AM SENSORS LTD AMS-S-084/DS/ (ISSUE 1)

ARI-SAFE-SN ANSI Safety valve ANSI - safety valve Semi Nozzle (ANSI )

Pressure and Flow Control Valves DBGM, German and European Patents

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Pressure reducing station. ARI-Pressure reducing station, self-acting or with electro-pneumatic control. ARI-PREsys -S. Pressure reducing station

Overflow valves Type OFV REFRIGERATION AND AIR CONDITIONING. Technical leaflet

TDC46M, TDS46M and UTDS46M Thermodynamic Steam Traps with Maintainable Seat Installation and Maintenance Instructions

Crosby Style JCE Safety Relief Valves provide full overpressure protection for process systems at an affordable cost of ownership.

PRESSURE REGULATORS GAS PRESSURE REDUCING

627 Series Pressure Reducing Regulators

Pressure reducing station. ARI-Pressure reducing station, self-acting or with electro-pneumatic control. ARI-PREsys -S. Pressure reducing station

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

PC10HP Pipeline Connector (ASME 600)

Hand-operated regulating valves in stainless steel Types REG-SA SS and REG-SB SS

TD10, TD52M and TD259 Thermodynamic Steam Traps Installation and Maintenance Instructions

Safety relief valves Type BSV-8

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

Gas Pressure Regulator HON 200

CA44, CA44S, CA46 and CA46S Air and Gas Traps

Transcription:

Data Sheet 819346-02 Issue Date: 05/17 Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300, 50, 65 UNA 45hl MAX, UNA 46hl MAX, UNA 46Ahl MAX UNA 45v MAX with cover for mounting electrode UNA 45v MAX with sightglass cover Description UNA 45 MAX, UNA 46 MAX and UNA 46A MAX are items of equipment for the steam process designed for the effective removal of condensate from steam. The ball float opens the orifice as a function of the liquid level. A rising level results in a proportional opening of the equipment. The max. discharge capacity depends on the size of the fully open orifice (O). As the float rises with the liquid level it pulls the nozzle stem off the pilot valve, allowing a small amount of fluid to flow through the pilot valve. The fluid compresses the bellows of the control unit and, as a consequence, the discharge orifice is completely uncovered. Equipment with control unit SIMPLEX is particularly suitable for cold condensates and superheated steam. Equipment with control unit DUPLEX may also be used for air venting the installation. The control unit DUPLEX consists of a float and a temperature dependent air-venting facility. The air venting is controlled by the membrane regulator. Equipment with this type of control unit is particularly suitable for saturated steam systems. Do not expose the membrane regulator capsule of the DUPLEX control unit to superheat conditions above 5 K. The optional float-lifting lever allows you to lift the float manually. The optional hand-vent valve allows you to air vent the pipe manually. The equipment must only be used within the allowable pressure and temperature limits and only if the chemical and corrosive influences on the equipment are taken into account. Function The control unit opens the orifice as a function of the liquid level. A rising level results in a proportional opening of the equipment. The max. discharge capacity depends on the orifice size when the ball is completely lifted off its seat and the orifice is fully open. Optional extras Standard cover with two lateral connections (with sealings plugs) for later attachment of measuring electrode and/or manual float-lifting lever Float-lifting lever allows the float to be manually lifted (for purging any dirt away from the seat area) Hand-vent valve allows manual air-venting the pipeline Horizontal flow direction (hr) from left to right (when viewed from the body end) Sightglass cover PN 16/CL 150 Special cover for mounting measuring electrode NRG 16-19 or NRG 16-27 The different equipment versions allow you to adjust the flow direction of the equipment to the flow pattern of your installation. The flow arrow must correspond to the direction of the fluid flow. The following positions of installation are possible: v Design "v" for installation in vertical pipework with downward flow hl "hl" for horizontal left hr "hr" for horizontal right End connections Flange EN 1092-1 B1 PN 40 Flange ASME B 16.5 Class 150 RF, 300 RF Screwed sockets G: ISO 228/1 Screwed sockets NPT: ASME B 16.11 Socket-weld ends to DIN EN 12760 Socket-weld ends ASME B 16.11 Class 3000 Butt-weld ends via transition pieces to EN 12627, welded joint geometry ISO 9692-1 code number 1.3 (30 chamfer) Butt-weld ends via transition pieces ASME B 16.25 ASME B 36.10 Materials Component part Type EN ASTM Body UNA 45 MAX, UNA 46 MAX 1.0460 A105 UNA 46A MAX 1.4404 A182-F316L UNA 45 MAX, sightglass cover 5.3103 A395 ) Cover UNA 46 MAX 1.0619 A216-WCB UNA 46A MAX 1.4408 A351-CF8M Body gasket, controller gasket, adapter gasket, gasket for reflexion water level gauge all Graphite CrNi Membrane regulator capsule all Hastelloy / stainless steel Other components all Stainless steel 1 ) Physical and chemical properties comply with EN grade. ASTM nearest equivalent grade is stated for guidance only. 1

Explosion view of UNA 45 MAX, UNA 46 MAX, UNA 46A MAX Item no. Designation 2 Body 3 Body gasket 22 Adapter gasket 6 Control unit (shown here: control unit DUPLEX) 8 Cover (shown here: standard cover) 12 Hand vent valve 15 Float-lifting lever 30 Socket spanner 37 Adapter for SIMPLEX version 5 Adapter for DUPLEX version Dimensions and weights H2 H L H1 L1 B UNA 45 MAX, UNA 46 MAX, UNA 46A MAX Control unit DUPLEX Flanged ends X Space required for servicing To remove the cover a withdrawal space S of 270 mm is required. If the supplied socket spanner is attached to the equipment an additional clearance of 100 mm is required. S 2

Dimensions and weights Equipment with flanges EN 1092-1 PN 10 40 L [mm (in)] All 230 (9.1) 290 (11.4) Sightglass cover 370 (14.6) H2 [mm (in)] All 182 (7.2) 1 ) H [mm (in)] All 280 (11.0) 1 ) L1 [mm (in)] All 160 (6.3) 2 ) Weight [kg] Standard cover 33.6 35.1 37.4 Sightglass cover 37.5 39.0 41.3 35.5 36.9 39.3 Weight [lb] Standard cover 74.1 77.4 82.5 Sightglass cover 82.7 86.0 91.0 78.3 81.3 86.6 Equipment with flange ASME CL150 and CL300 Class 150 Class 300 L [mm (in)] All 241 (9.5) 267 (10.5) 292 (11.5) 241 (9.5) 267 (10.5) 292 (11.5) Sightglass cover 370 (14.6) H2 [mm (in)] All 182 (7,2) 1 ) H [mm (in)] All 280 (11,0) 1 ) L1 [mm (in)] All 160 (6,3) 2 ) Weight [kg] Standard cover 32.6 34.6 38.2 34.8 36.2 39.9 Sightglass cover 36.5 38.5 42.1 34.5 36.5 40.1 36.7 38.1 41.7 Weight [lb] Standard cover 71.9 76.3 84.2 76.7 79.8 88.0 Sightglass cover 80.5 84.9 92.8 76.1 80.5 88.4 80.9 84.0 91.9 3

Dimensions and weights - continued - Equipment with socket-weld ends L [mm (in)] All 165 (6.5) 267 (10.5) 292 (11.5) Sightglass cover 370 (14.6) H2 [mm (in)] All 182 (7,2) 1 ) H [mm (in)] All 280 (11,0) 1 ) L1 [mm (in)] All 160 (6,3) 2 ) Weight [kg] Standard cover 29.9 30.9 32.2 Sightglass cover 33.8 34.8 36.1 31.7 32.8 34.1 Weight [lb] Standard cover 65.9 68.1 71.0 Sightglass cover 74.5 76.7 79.6 69.9 72.3 75.2 Equipment with screwed socket L [mm (in)] All 165 (6.5) Sightglass cover 370 (14.6) H2 [mm (in)] All 182 (7,2) 1 ) H [mm (in)] All 280 (11,0) 1 ) L1 [mm (in)] All 160 (6,3) 2 ) Weight [kg] Standard cover 30.1 29.6 Sightglass cover 34.0 33.5 32.0 31.4 Weight [lb] Standard cover 66.4 65.3 Sightglass cover 75.0 73.9 70.5 69.2 Equipment with butt-weld end via transition pieces L [mm (in)] All 241 (9.5) 267 (10.5) 292 (11.5) Sightglass cover 370 (14.6) H2 [mm (in)] All 182 (7,2) 1 ) H [mm (in)] All 280 (11,0) 1 ) L1 [mm (in)] All 160 (6,3) 2 ) Weight [kg] Standard cover 30.1 30.4 31.3 Sightglass cover 34.0 34.3 35.2 32.0 32.3 33.2 Weight [lb] Standard cover 66.4 67.0 69.0 Sightglass cover 75.0 75.6 77.6 70.5 71.2 73.2 4

Pressure & temperature ratings The values indicated in the following tables apply to standard equipment. Note that the type of end connection used may restrict the use of the equipment to below the pressure/temperature limits quoted. All equipment specific values are indicated on the nameplate. Limiting conditions for UNA 45 MAX and UNA 46 MAX: Flange PN 40, screwed socket G Pressure 1 ) p [barg] 40 37.1 33.3 27.6 25.7 13.1 2 ) Temperature 1 ) T [ C] -10/20 100 200 300 350 450 2 ) [barg] 4, 8, 13, 22, 32 [psi] 58, 116, 188, 320, 465 Pressure 1 ) p [psig] 580 538 483 400 373 190 2 ) Temperature 1 ) T [ F] 14/68 212 392 572 662 842 2 ) 1 ) Resistance limits for body/cover to EN 1092-1 2 ) Not for UNA 45 MAX Limiting conditions for UNA 45 MAX and UNA 46 MAX: Flange Class 150 Pressure 1 ) p [barg] 19.6 17.7 13.8 10.2 8.6 5.5 2 ) Temperature 1 ) T [ C] -29/20 100 200 300 345 425 2 ) Operating data Equipment with sightglass cover: PN16: max. service temperature 240 C at a service pressure of 12.3 bar Class 150: max. service temperature 240 C at a service pressure of 12.4 bar If the ph value is above 9.0 and the fluid temperature exceeds 200 C the glass will wear down faster. Equipment with measuring electrode NRG 16-19 or NRG 16-27, PN 40/Class 300: max. service temperature 238 C at 32 bar service pressure The max. differential pressure Δ PMX of the equipment depends on the type of orifice (O) used. Orifice... MAX [barg] Diameter of bore [mm] 4 4 27.5 8 8 19.4 13 13 15.3 22 22 11.7 32 32 9.7 Equipment with control unit DUPLEX: max. service temperature corresponds to the saturation temperature +5K. [barg] 4, 8, 13 (19.6 barg with orifice 22, 32) [psi] 58, 116, 188, (284 psi with orifice 22, 32) Pressure 1 ) p [psig] 285 260 200 140 125 80 2 ) Temperature 1 ) T [ F] 20/100 200 400 600 650 800 2 ) 2 ) Not for UNA 45 MAX Limiting conditions for UNA 45 MAX and UNA 46 MAX: Flange Class 300, screwed socket NPT, socket-weld end, butt-weld end Pressure 1 ) p [barg] 51.1 46.6 43.8 39.8 37.8 28.8 2 ) Temperature 1 ) T [ C] -29/20 100 200 300 345 425 2 ) [barg] 4, 8, 13, 22, 32 [psi] 58, 116, 188, 320, 465 Pressure 1 ) p [psig] 740 680 635 570 550 410 2 ) Temperature 1 ) T [ F] 20/100 200 400 600 650 800 2 ) 2 ) Not for UNA 45 MAX Limiting conditions for UNA 45 MAX with sightglass cover: Flange PN 16, screwed socket G Pressure 1 ) p [barg] 16.0 14.8 14.0 13.3 12.3 Temperature 1 ) T [ C] -10/20 100 150 200 240 [barg] 4, 8, 13 (16 barg with orifice 22, 32) [psi] 58, 116, 188, (230 psi with orifice 22, 32) Pressure 1 ) p [psig] 232 215 203 193 178 Temperature 1 ) T [ F] 14/68 212 302 392 464 1 ) Resistance limits for body/cover to EN 1092-1 5

Limiting conditions - continued - Limiting conditions for UNA 45 MAX with sightglass cover: Flange Class 150, screwed socket NPT, socket-weld end, butt-weld end Pressure 1 ) p [barg] 19.6 17.7 15.8 13.8 12.4 Temperature 1 ) T [ C] -29/20 100 150 200 240 [barg] 4, 8, 13 (19.6 barg with orifice 22, 32) [psi] 58, 116, 188, (284 psi with orifice 22, 32) Pressure 1 ) p [psig] 285 260 230 200 180 Temperature 1 ) T [ F] -20/100 200 300 400 465 Limiting conditions for UNA 46A MAX: Flange PN 40, screwed socket G Pressure 1 ) p [barg] 40.0 37.9 31.8 27.6 25.7 25 Temperature 1 ) T [ C] -10/20 100 200 300 400 2 ) 450 2 ) [barg] 4, 8, 13, 22, 32 [psi] 58, 116, 188, 320, 465 Operating data Equipment with sightglass cover: PN16: max. service temperature 240 C at a service pressure of 12.3 bar Class 150: max. service temperature 240 C at a service pressure of 12.4 bar If the ph value is above 9.0 and the fluid temperature exceeds 200 C the glass will wear down faster. Equipment with measuring electrode NRG 16-19 or NRG 16-27, PN 40/Class 300: max. service temperature 238 C at 32 bar service pressure The max. differential pressure Δ PMX of the equipment depends on the type of orifice (O) used. Orifice... MAX [barg] Diameter of bore [mm] 4 4 27.5 8 8 19.4 13 13 15.3 22 22 11.7 32 32 9.7 Equipment with control unit DUPLEX: max. service temperature corresponds to the saturation temperature +5K. Pressure 1 ) p [psig] 580 550 461 400 373 363 Temperature 1 ) T [ F] 14/68 212 392 572 752 842 1 ) Resistance limits for body/cover to EN 1092-1 2 ) If the operating temperatures exceed 300 C intercrystalline corrosion may occur. Do not subject the equipment to operating temperatures higher than 300 C unless intercrystalline corrosion can be ruled out. Limiting conditions for UNA 46A MAX: Flange Class 150 Pressure 1 ) p [barg] 15.9 13.3 11.2 10.0 6.5 5.5 Temperature 1 ) T [ C] -29/20 100 200 300 400 2 ) 425 2 ) [barg] 4, 8, 13 (15.9 barg with orifice 22, 32) [psi] 58, 116, 188, (230 psi with orifice 22, 32) Pressure 1 ) p [psig] 230 195 160 140 95 80 Temperature 1 ) T [ F] 20/100 200 400 600 750 800 2 ) If the operating temperatures exceed 300 C intercrystalline corrosion may occur. Do not subject the equipment to operating temperatures higher than 300 C unless intercrystalline corrosion can be ruled out. Limiting conditions for UNA 46A MAX: Flange Class 300, screwed socket NPT, socket-weld end, butt-weld end Pressure 1 ) p [barg] 41.4 34.8 29.2 26.1 24.3 23.9 Temperature 1 ) T [ C] -29/20 100 200 300 400 2 ) 425 2 ) [barg] 4, 8, 13, 22, 32 [psi] 58, 116, 188, 320, 465 Pressure 1 ) p [psig] 600 510 420 370 355 345 Temperature 1 ) T [ F] -20/100 200 400 600 750 800 2 ) If the operating temperatures exceed 300 C intercrystalline corrosion may occur. Do not subject the equipment to operating temperatures higher than 300 C unless intercrystalline corrosion can be ruled out. 6

Capacity Chart The chart shows the maximum capacities for hot condensate for the respective orifice. The capacities are dependent on the differential pressure (working pressure). The differential pressure is the difference between inlet and outlet pressure and depends among other things on the run of the condensate line. If the condensate downstream of the trap is lifted, the differential pressure is reduced by 1 bar for 7 m lift. The maximum admissible differential pressure is dependent on the cross-sectional area of the orifice and the density of the liquid to be discharged. The charts show the maximum capacities for hot and cold condensate. Capacity chart for hot condensate [lb/h] [kg/h] 30000 60000 20000 40000 30000 10000 20000 8000 6000 5000 10000 4000 8000 3000 6000-65 - Orifice 4 MAX -65 - Orifice 8 MAX -65 - Orifice 13 MAX -65 - Orifice 22 MAX -65 - Orifice 32 MAX Capacity 4000 3000 2000 2000 1000 0,1 0,2 0,3 0,4 0,6 0,8 1 2 3 4 5 6 8 10 20 [bar] 32 [psi] 1,5 2 3 4 6 8 10 20 30 40 60 80 100 200 300 465 Differential pressure Capacity chart for cold water [lb/h] 60000 40000 30000 20000 10000 8000 6000 [kg/h] 30000 20000 10000 8000 6000 5000 4000 3000-65 - Orifice 4 MAX -65 - Orifice 8 MAX -65 - Orifice 13 MAX -65 - Orifice 22 MAX -65 - Orifice 32 MAX Capacity 4000 3000 2000 2000 1000 0,1 0,2 0,3 0,4 0,6 0,8 1 2 3 4 5 6 8 10 20 [bar] 32 [psi] 1,5 2 3 4 6 8 10 20 30 40 60 80 100 200 300 465 Differential pressure 7

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300, 50, 65 Spare Parts 3 22 29 6 12 31 Inspection & Certification Documentation regarding material tests and in-house examination with test report EN10204 available. All inspection requirements have to be stated with the enquiry or order. After supply of the equipment certification cannot be established. Charges and extent of the above mentioned test certificates as well as the different tests confirmed therein are listed in our Price List "Test and Inspection Charges for Standard Equipment". For other tests and inspections than those listed above, please consult us. Application of European Directives Pressure Equipment Directive The equipment conforms to this directive and can be used for the following media: UNA 45 MAX Fluids of group 2 UNA 46 MAX and UNA 46A MAX Fluids of group 1 Fluids of group 2 ATEX Directive The equipment does not have its own potential ignition source and is not subject to this directive. When installed, static electricity may arise between the equipment and the connected system. When used in potentially explosive atmospheres, the plant manufacturer or plant operator is responsible for discharging or preventing possible static charge. If it is possible for medium to escape, e.g. through actuating mechanisms or leaks in threaded joints, the plant manufacturer or plant operator must take this into consideration when dividing the area into zones. 26 Item no. Designation 3, 6 22 26 3, 29 12, 14 30 14, 15 30 Control unit, complete with body gasket, adapter gasket and gasket for control unit 30 Membrane regulator capsule 5N2, cpl. with body gasket Hand-vent valve, cpl. with joint ring and socket spanner Float lifting lever, cpl. with joint ring and socket spanner 15 Stock code # Orifice Standard cover Sightglass cover 4 560690 8 560691 13 560692 22 560693 560693 32 560694 560694 all 560687 14 33 all 560676 all 560678 3 Body gasket 1 ) all 560680 22 Adapter gasket 1 ) all 560682 14 Gasket for sealing plug 3 /8", float-lifting lever, hand-vent valve 1 ) all 560486 2 ) or 560514 2 ) 26 Gasket for control unit 3 ) all 560547 3, 14 22, 26 Gasket set 4 ) all 560684 560684 30 Socket spanner all 560700 31, 33 Reflexion water level gauge with 2 gaskets all 560480 1 Delivery quantity: 20 pcs 2 560486: Material 1.4301, 560514: Material 1.4571 3 Delivery quantity: 10 pcs 4 Contains: 4 gaskets 3 /8" 1 body gasket 1 gasket for control unit 1 adapter gasket Supply in accordance with our general terms of business. GESTRA AG Münchener Straße 77, 28215 Bremen, Germany Telefon +49 421 3503-0, Telefax +49 421 3503-393 E-mail info@de.gestra.com, Web www.gestra.de 819346-02/05-2017cm (808924-02) GESTRA AG Bremen Printed in Germany 8