Fall Speed vs. Reaction Time

Similar documents
Fall Protection. Fall Speed vs. Reaction Time. Good body reaction time = 0.5 seconds Travel distance in 0.5 seconds = 4 feet (1.21mts.

TAMPA ELECTRIC COMPANY ENERGY SUPPLY FALL PROTECTION PROGRAM

DREW UNIVERSITY FALL PROTECTION PROCEDURE (DRAFT 12/11)

Fall Protection Checklist. Guardrail System

Progressive Safety Services LLC

City of New London. Fall Protection. Program

Fall Protection ABC s

QO9.d.. e v -.PXresat

Section 16B. Fall Protection. Falls are the second leading cause of death in the workplace. Factors contributing to falling incidents:

Suffolk County Community College. Fall Protection Program. April 2014

You may order this publication from WCB Publications and Videos, Please quote ordering number BK60.

OPE Training Seminar Agenda

"FALL PREVENTION IN THE WORKPLACE"

IMPORTANT: If you have questions on the use, care, application, or suitability of this equipment contact DBI/SALA.

User Instructions 1790 Rail Anchor

Fall Protection STANDARD PROCEDURE INSTRUCTION. Fall Protection. Title SPI. Department. Supersedes SPI Dated. Jan 19, 2016.

Doc No: FPP CARDINAL SURVEYS COMPANY. Safety Management System. Initial Revision Date: Version Revision No. 02 FALL PROTECTION

INSTRUCTIONS FOR USE

Marquette University Fall Protection Program

Fall Protection Program

User Instructions 1789 Parapet Wall Anchor

What is fall protection?

GEMTOR. ... when your life is on the line OWNER'S MANUAL. FLW Series Self-Retracting Lanyard/Fall Limiter

1 of 15. Policy Number 61. Last Update: March 21, Effective Date: 11/22/11 Resolution No Title: Fall Protection Policy POLICY STATEMENT

workplace fatalities involving falls to a lower level. Fall related fatalities make up 16% of workplace fatalities

"FALL PROTECTION IN CONSTRUCTION ENVIRONMENTS"

WARNING! DO NOT THROW AWAY THESE INSTRUCTIONS! READ AND UNDERSTAND BEFORE USING EQUIPMENT!

ILLINOIS INSTITUTE OF TECHNOLOGY SAFETY POLICY COMMITTEE. Fall Protection Program

FALL PROTECTION. Leader s Guide. Marcom Group Ltd.

INSTRUCTIONS FOR USE

1.3 LIMITATIONS: The following application limitations must be recognized and considered before using this product:

UNIVERSITY OF MINNESOTA University Health and Safety FALL PROTECTION PROGRAM

At the end of this presentation you should know the difference between fall prevention, fall restraint, and fall arrest.

FALL PROTECTION PROGRAM

USER S INSTRUCTION MANUAL FOR THE INSTALLATION, OPERATION & MAINTENANCE OF THE GUARDIAN TEMPORARY HORIZONTAL LIFELINE SYSTEM

Product Name: Concrete Anchor Strap

New Mexico Institute of Mining & Technology. Fall Protection Program

Product Name: Internal Shock Lanyard

Dutchess Community College. Fall Protection Program

FALL PROTECTION PLAN FALL PROTECTION PROGRAM

1.2 LIMITATIONS: Consider the following application limitations before using this equipment:

FREQUENTLY ASKED QUESTIONS ABOUT FALL PROTECTION

Fall Protection 4/7/16

Step By Step How to Establish, Manage and Implement a Fall Protection Program

Subchapter 4. Construction Safety Orders Article 24. Fall Protection. Return to index New query

PFI Fall Protection Best Practice

INSTRUCTIONS FOR USE

FACILITIES MANAGEMENT OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY Fall Protection Policy 11/21/14 Last Revision

Module Overview Module Description Not a substitute for standards. Training should not be considered as substitute for safety and health standards for

11.4 FALL-ARREST SYSTEM AND EQUIPMENT CHECKLIST (Must answer yes to all applicable questions)

FALL PROTECTION PLAN July 2012

Fall Protection. Fall Protection

Product Name: Hold Me Rope Anchor

FALL PROTECTION SAFETY PROGRAM

Title: Fall Protection Policy. University Division/Department: Environmental Health & Safety Effective Date : Revised:

ARKANSAS TECH UNIVERSITY FACILITIES MANAGMENT HEALTH AND SAFETY MANUAL

1.0 Scope and Application

Risk Control at United Fire Group

Safety Manual Page 1 of 15

User Instruction Manual Roof Anchor and / Sayfline Horizontal Lifeline System

NOTE WARNING! PHOENIX, AZ USA USER INSTRUCTION MANUAL WATCH VIDEOS 6, 12 & 25 ON ULTRASAFEUSA.COM MODEL: SIZE: DATE:

WrapBax 2 Lanyards With Integral Energy Absorbers

INSTRUCTIONS FOR USE

User Manual 1792 Standing Seam Metal Roof Retractable Swivel Anchor

8. Fall Protection Procedures WAC

FALL PROTECTION / ELEVATED WORK

WARNING! DO NOT THROW AWAY THESE INSTRUCTIONS! READ AND UNDERSTAND BEFORE USING EQUIPMENT!

Instructions for the following series products:

Fall Protection Refresher Orientation. Fall Protection Refresher Orientation 1

IMPORTANT: Record the product identification information from the ID label in the inspection and maintenance log in section 9.0 of this manual.

INSTRUCTIONS FOR USE

Fall Protection PPE Inspection

Instructions for The Rose Crossover Style Full Body Harness For Women

Fall Protection- Part 2

To remind workers that falling from heights can result in serious injury. Enter your name and the training date on the Training Sign-In Sheet.

USER INSTRUCTIONS LARGE HOOK & STRAP ANCHORAGE CONNECTOR ! WARNING

SAFETY DIRECTIVE 2.0 DEPARTMENTS AFFECTED. This Administrative Directive shall apply to all Town of Marana departments and employees.

Fall Protection Introduction

Product Name: Non-Shock Lanyard

Serial Number: Lot Number: Purchase Date: General Factors Accepted / Rejected Supportive Details or Comments. Accepted Rejected.

Inspection & Maintenance

Fall Protection PPT-SM-FALLPROT V.A.0.0

Product Name: Edge Series Web SRL

VERSION 1.0 FEBRUARY 1, 2017 FALL PROTECTION AND ELEVATED WORK UNC CHARLOTTE 9201 UNIVERSITY CITY BLVD., CHARLOTTE, NC 28223

Rescue ladder System. User Instruction Manual

Instructions for Y Style Full Body Harness Model YH130

A. Employer Provide fall protection to effected employees Ensure that all employees understand and adhere to the procedures of this plan

This training session provides important information on fall protection at construction sites. Anyone who is exposed to potential fall hazards must

Region: USA Language: EN Number : TB0031 Revision : B. Total Page: 3 Page n : 1 First Issue: 10/2014 Rev. Date: 10/08/2014

1 of 9 12/30/15, 3:44 PM

INSTRUCTION, CARE & MAINTENANCE GUIDE FULL BODY HARNESSES (FBH)

SECTION FACILITY FALL PROTECTION PART I - GENERAL

User Instruction Manual Fixed Beam Anchor

USER INSTRUCTIONS. Complies with ANSI Z359.1, ANSI Z359.4 standards and OSHA 29 CFR 1910 and 1926 regulations.

ROOF ANCHOR / D-RING ANCHOR PLATE

Fall Protection. 29 CFR Appendix C 29 CFR 1926 Subpart M

Patrick Harel Ph

FALL PROTECTION (SAF-SPI-06)

29 CFR 1926, Subpart M. Fall Protection Program Table of Contents

Fall Protection. Requirements The procedure requires the user of fall protection to be 100% tied off at all times when:

Transcription:

Fall Protection

Fall Speed vs. Reaction Time Good body reaction time = 0.5 seconds Travel distance in 0.5 seconds = 4 feet (1.21mts.) In 1 second your body will fall 16 feet (4.8 mts.) By the time you react your body will be 6½ feet (2 mts) below where you were standing

When do you need Fall Protection OSHA s Regulation 29 CFR 1926.501 (b) under Subpart M requires fall protection wherever the potential to fall six feet or more exists. Fall protection is required when you are: six feet of an unprotected roof edge; working in a unguarded mezzanine and balcony edges;

When do you need Fall Protection (CONT D) Fall protection is also required in the following locations: working off aerial lift; unguarded scaffolding 10 feet or higher

Types of Fall Protection Systems Passive System is a physical barrier that restricts a worker from entering a fall hazard. Active System will stop employees fall and limit the fall to specified distance and will limits the amount of force a person is subjected to in the event of a fall.

Examples of Fall Protection Systems Passive fall protection systems include: Perimeter guardrails Safety Net Safety Monitors Active Fall Protection Systems include: Life lines Work positioning device Personal Fall Arrest Equipment

Common Fall Protection Systems in Our Industry Perimeter Guarding A physical barrier that restricts a worker from entering a fall hazard area. Personal Fall-Arrest Systems A system that will stop a workers fall and limit the fall to a specified distance. Limits the amount of force a person is subjected to in the event of a fall.

Perimeter Guarding Perimeter guarding shall consist of a mid-rail, top-rail, toe-board system. The top edge height of the rail shall be 42+/-3 inches and the mid-rail should be between the top and the walking/working level. On scaffolds a guardrail will consist of a toe board, mid rail and top rail.

Personal Fall-Arrest Systems A Personal Fall-Arrest System is a system used to arrest an employee in a fall from a working level. Any person ordered to work with at height who has an increase risk of falling off of structures/buildings should wear a personal fall arrest system.

Personal Fall-Arrest Systems (cont d) Personal Fall-Arrest Systems, when stopping a fall shall be rigged such that a worker can neither free fall more than six feet, nor contact any lower level. Must have a minimum breaking strength of 5,000 pounds.

Personal Fall-Arrest Systems A personal fall-arrest system shall consist of the following: Anchorage points, Full body harness, Shock Absorbing Lanyard, Lifeline, Rope-grabs, Connectors All components of the fall arrest system shall be fully compatible.

Anchorage Points An anchorage is a secure point of attachment for lifelines, lanyards or deceleration devices; Must be independent of any anchorage being used for equipment tiebacks; Must be independent of the means of supporting or suspending the worker; Must be capable of supporting at least 5,000 pounds per worker; Sound anchorages include certified roof anchors as well as structural members.

IMPROPER IMPROPER Anchorage Points Standard Guardrails or Railings Ladders/Rungs Scaffolding Light Fixtures Conduit or Plumbing Ductwork or Pipe Vents Antennas or Satellite Dishes Anything else that you re not sure of!

Full Body Harness Must be the right size for you. The attachment point of a body harness shall be located on the: Rear D-ring between shoulders when working from a suspended scaffold or an aerial lift Front D-ring when working from a bosun s chair. Harness must be adjusted snugly starting with leg straps, then waist, shoulders and chest.

Lanyards Used to connect a body harness to a lifeline, rope-grab, or anchorage point. Shall be the appropriate length: Bosun s chair 2 feet or less Suspended scaffold 3 to 4 feet Aerial lift 4 to 6 feet Attach to: Rear D-ring on harness between shoulders when working on suspended scaffolds and aerial lifts. Front D-ring when working from a bosun s chair. Be protected against being cut or abraded.

Lifelines Vertical - connected to an anchorage at one end to hang vertically. Horizontal - connected to anchorages at both ends to stretch horizontally.

Lifelines (cont d) are used as a means of connecting other components of a Personal Fall-Arrest System. shall be protected from contact with any surface that may abrade, weaken, damage or sever it. shall be removed from service as recommended by the manufacturer.

Rope-Grabs A Rope-Grab is a deceleration device which travels on a lifeline and automatically engages the lifeline and locks to arrest the fall of an employee. When securing the rope grab at the work location, it should be raised above eye level, securely engaging the lifeline.

Connectors A Connector is a device which is used to couple (connect) parts of the system together. It may be an independent component of the system (such as a carabiner), or an integral component of part of the system (such as a buckle or D-ring sewn into a body harness, or a snap-hook spliced or sewn to a lanyard). The following are considered acceptable connectors: Self-locking snap hooks Autolocking & screwgate carabiners Quick-links connectors, etc. Snaphooks shall be a double locking-type. Screwgate carabiners and quick-link connectors must be fully threaded.

Inspection of Fall Protection Systems The following criteria will be utilized to maintain all equipment in good working condition:

Full Body Harnesses Inspect before each use. Assure that all hardware (ie. D-rings, buckles, etc.) work properly and that they do not have any sharp edges, burrs, cracks or corrosion. Inspect webbing for wear, cuts, burns, frayed edges or other damage. Inspect all stitching for abrasion and wear to assure integrity.

Inspect before each use. Lanyards Check lanyard material for cuts, burns, abrasions, kinks, knots, broken stitches and excessive wear. Visually inspect shock absorber for any signs of damage. Verify that points where the lanyard attaches to the connectors are free of defects.

Lifelines Inspect before each use, checking for the following: Glazing of the sheath caused by the fibers being melted. Severe furring of the rope. Soft spots, caused by changes to the internal structure of the core. Cutting of sheath fibers due to contact with sharp edges. Any sign of the core showing through (rope cores are always white).

Inspect before each use. Connectors Inspect the snap hooks for distortions in the hook, locks, and eye. Verify that the keeper spring securely closes the keeper latch. Test the locking mechanism to verify that the keeper latch locks properly. Check carabiner for excessive wear, distortion, and lock operation. Ensure that all locking mechanisms seat and lock properly. Verify there are no cracks or pitted surfaces.

Care for Fall Arrest Systems Clean equipment after use. Air dry equipment, do not hang in direct sunlight. Store equipment in a cool, dark, dry well ventilated place. Do not alter equipment in any way. Use caution when using equipment around moving machinery, electrical hazards, sharp edges, chemical hazards and high heat environment or flame. All components of a Personal Fall Arrest System that are involved in a fall shall be immediately removed from service and disposed of or destroyed.

Remember! Always use approved anchor points. Always make sure fall protection is sufficient for the job. Always inspect your fall protection system prior to each use. Do not use fall protection system to carry materials or tools. Always tie off when coming within 6 feet of an unprotected edge.