EcoCell Vertical Electrophoresis Unit

Similar documents
Vertical Gel Electrophoresis Systems

Topac Inc. 101 Derby Street Hingham MA USA Tel

Type BBS-03, BBS-05, BBS-06, BBS-25

Supratec Gesellschaft für Umweltund Verfahrenstechnik mbh OXYFLEX - M T / M T M E M B R A N E D I S C D I F F U S ER AERATION TECHNOLOGY

AQUARIUS. Operating Instructions for the. Type 70 Electrolytic Gas Soldering / Welding Unit. Table of Contents

PURA. Pure Gas Dewpoint Transmitter. Users Guide

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

Techcon Systems TS1258 Pressure Pot

Operation Manual. PEGAS NovoTap, PEGAS NovoTap+

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

Medium Voltage Switchgear. Installation Manual for Pressure Relief Ducts

WELLS JOHNSON HIGH VOLUME CANISTERS

Flexi-pro Aerosol Delivery System (FADS) Manual

DEH Instructions. Three-Phase, Platform-Mounted Distribution Transformers

Digital Melting Point Apparatus

INSTRUCTION MANUAL. January 23, 2003, Revision 0

UsER manual for Watersens ph -REDOX

Instructions for use Compressed air injector with water trap

Entry to these spaces must be rigorously controlled to prevent serious injury or death.

Operating Instructions

Techcon Systems TS1254 Pressure Pot

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

PO Box 370 Phone: Swansea NSW 2281 Fax: AUSTRALIA Mobile: Web:

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

Norrsken Family Booklet

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

VERTICAL AIR COMPRESSORS

7130 Lancer Rear Drive Magnetic Commercial Indoor Cycling Bike

32374 R. Jazowski 4/4/ D. W. Mudge G. Sivik 1 of 8 ODN TITLE: Installation & Operation Manual for Nautilus G2 Connectors

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

Spectrum AquaLight (SAL ) Color Underwater Light Owner s Manual

Paintball Marker. User s Manual. 530 South Springbrook Road Newberg, OR 97132

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

OPERATING INSTRUCTIONS Sherlock Chamber Testing System

Modular valve block. Operating manual Series MVB 100/200. Version BA EN Print-No TR MA DE Rev001

1. CONDITIONS FOR USE 2. SAFETY

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

GI Series Diaphragm Pressure Gauge Guard

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064

OWNER S MANUAL SUCTION GUN SG-300

LRS(H)4 Pressure-Reducing Regulator User Manual

MoveRoll Conveyor Operating and Maintenance Manual

Instruction Manual Otoflash G171 UV-flash-device for Light Curing

TECHNICAL DATA CAUTION

Declaration of Conformity as per Directive 97/23/EC

MODEL ANALOG ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.2 TO 100FT OPERATING RANGE ANALOG OUTPUT

APT Electrofusion Ducting

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Training. Testor Training Manual

! WARNING! IMPORTANT HPA AIR TANK SAFETY INSTRUCTION AND GUIDELINES ! WARNING! IMPORTANT SAFETY INSTRUCTION AND GUIDELINES

Unisense In Situ UniAmp Connector System

INSTRUCTION MANUAL. Gas Salamander

NovelBright LED Illuminator

Multi-Probe Sampling System User Guide & Manual

Operating Manual. 3S-R AirElite Full Face Mask Advantage AirElite Full Face Mask Advantage 4000 AirElite Full Face Mask. AirElite - Full Face Masks

BOC: Living healthcare. Manual. LIV IQ BOC Integrated Valve with digital display portable delivery system for Medical Oxygen. BOC: Living healthcare

QUIK-jet Micro-Injection System

Arbor Terminator Press Operation Manual For IDT Connectors Order No Engineering No: AM

Sample Concentrator SBH CONC/1 Instructions for use

24L AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: RANGER 7/240 PART NO: LS0913

Radnoti Liver Perfusion System

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Service and Repair Manual

Vetter Leak-Sealing Systems

Safety instructions and operating manual

2-1- Shipping Receiving Lifting Location on Site Installation Stages 6

PCS 340 Core Saturator : 115 Volt : 230 Volt. Instruction Manual

ST 18 Aluminium Gas Model

Squeegee Unit for MRS Multi-Recovery System

Filter cartridge protection class A2 Organic vapours, with boiling point above 65 C, to 50X OEL or 1000 ppm, whichever is the lower.

RD(H)20/25 Pressure-Reducing Regulator User Manual

CUT OFF TOOL MODEL: CAT113

DL 8 Dome Port. Product Registration. Product Number 75340

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

MODEL DIGITAL ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.5 TO 100FT (0.15 TO 30M) OPERATING RANGE SERIAL OUTPUT

Type C-CUT. Quickstart. English Deutsch Français

Code AWC20HP Air Compressor

APPROVED FOR USE IN SOUTH AFRICA STAINLESS STEEL STOVE

E X R A D I N. Parallel Plate Ion Chambers User Manual DOC #

Threaded Closures Installation, Operation & Maintenance

BUTTERFLY VALVES Series 800

Anti-flood device Model B-1

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

Auto-Rewind Hose Reels INSTRUCTION MANUAL FOR OXY-LPG MODEL

DIP STATION WITH SAFETY CONNECTOR SF-BH6507 USER MANUAL

TECHNICAL DATA. Trimpac 244a. September 16, 2013

A17W23_MASE_MUS_EN MANUAL

24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

INSTRUCTION MANUAL. (Variante 2 / System 2) Surgery table standard (Variante 1 / System 1)

DelVal Flow Controls Private limited

Siphon vessel / Priming aid

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May

Gas Sampling Fitting with MK2.1 and L-Probe

E X R A D I N Spherical Ion Chambers A3. A4 REF DOC #

Version BA D

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

Transcription:

Instructions for EcoCell Vertical Electrophoresis Unit Cat. No.: AN 12005 Ringstr. 4 64401 Gross-Bieberau Tel. ++49-6162-809840 Fax ++49-6162-8098420 www.anamed-gele.com

Warning These units are capable of delivering potentially lethal voltage when connected to a power supply and are to be operated only by qualified technically trained personnel. Please read the entire operator s manual thoroughly before operating this unit. The anamed vertical electrophoresis units are designed to give long service and reproducible results in your laboratory. A few moments spent reading these instructions will ensure that your expectations are reflected in the successful use of the apparatus. First check that the apparatus has been received complete and undamaged following shipment. Any fault or losses must be notified to anamed Elektrophorese GmbH immediately, anamed cannot accept reponsibility for goods returned without prior notification. Refer to the packaging list and check that all components ans accessories are present. Please retain all packaging materials until warranty period has expired. Specification Doubly insulated cables, rated safe up to 600 volts Gold plated electrical connectors, corrosion-free and rated safe up to 600 volts Recessed power connectors, integral with safety lid 0.2 mm diameter platinum electrodes, 99.99 % pure User replacable platinum electrodes Silicone rubber seal provides leak-free sealing and are easy to clean and/or replace User friendly clamping system Dimensions: 210 x 140 x 150 mm (breadth, depth, height) Weight: 2100 g Material: PMMA, PVC, POM, Silicone, PA, V4A, Buffer Capacities: Upper chamber: ~ 200 ml Lower chamber: ~ 500 ml minimum, ~ 1300 ml maximum Electrical Limits: 250 V @ 400 ma per gel Temperature Limit: 55 C Chemical Resistence: not compatible with aromatic or halogenated hydrocarbons, ketones, esters, alcohols (above 25 %) and acids (above 25 %). Environmental Conditions This apparatus is intended for indoor use only. This apparatus can be operated safely up to an altitude of 2000 m. The normal operating temperature range is between 4 C and 65 C. Maximum relative humidity 80 % for temperatures up to 31 C decreasing linearly to 50 % relative humidity at 40 C. 2

Packaging List Outer buffer chamber (running tank) 1 Safety lid with cables 1 Internal running module for precast gels with a cassette format of 10 x 10 cm 1 Dummy plate 1 AnaCut gelknife 1 Instruction manual 1 Using the EcoCell Vertical Gel Electrophoresis Unit Safety Precautions Read the instructions before using the apparatus. Always isolate electrophoresis units from their power supply before removing the saftety lid. Isolate the power supply from the mains first then disconnect the leads. Do not exceed the maximum operating voltage or current Maximun operating voltage: Maximum operating current: 500 V 250 ma Do not operate the electrophoresis units in metal trays. Wear effective protective clothing and follow recommended handling and disposal procedures. Polymerised gels can contain some unpolymerised monomer. Handle with gloves only. Following the replacement of a platinum electrode have the unit inspected and approved by your safety officer prior to use. Do not fill the unit with running buffer above the maximum fill lines. Do not move the unit when it is running. Caution: During electrophoresis very low quantities of various gases are produced at the electrodes. The type of gas produced depends on the composition of the buffer employed. To disperse these gases make sure that the apparatus is run in a ventilated area. 3

General Care and Maintenance To remove the safety lid, push thumbs down on the plastic lugs and lift the lid vertically with your fingers. After use clean and dry the apparatus with distilled water only. Important: Acrylic plastic is not resistant to aromatic or halogenated hydrocarbons, ketones, esters, alcohols (above 25 %) and acids (above 25 %). These chemicals will cause crazing and should not be used for cleaning. Do not use abrasive creams or scourers. Dry components with clean tissue after use. Before use, and then on a monthly basis, check the unit for any leaks at the bonded joints. Place the unit on a sheet of dry tissue and then fill with distilled water only to the maximum fill line. Any leakage will be seen on the tissue paper. If any leakage is seen do not attempt to repair or use the apparatus but notify anamed Elektrophorese GmbH immediately. The replacement platinum electrodes are partially shrouded for protection. However, when cleaning the internal running module do not use cleaning brushes in the electrode area. Usually a thorough rinse with distilled water is all that is required. Ensure that the connectors are clean and dry before usage or storage. Running Precast Gels Prepare the samples according to your procedures. Remove the gel from the pouche and rinse the cassette with distilled water. Remove the tape at the lower part of the cassettes and the comb. Remove the internal running module from the tank and put it on the bench. For easy loading of the samples insert the cassettes into the internal running module as follows: both notched plates facing the user, the rear cassette should sit slightly higher than the front gel (Fig. 1). Tighten the srews. Note: If you are running only one gel, the dummy plate replaces the second gel cassette. Make sure the sample wells in the cassette are completely filled with running buffer, and underlay the samples. Note: If the wells are not filled with running buffer, samples from one well will flow into the adjoining wells by means of capillary action. Loosen the screws and insert cassettes with both notched plates facing inwards and push them down to the bottom of the internal running module. Tighten the screws. Do not over tighten. 4

Place the inner running module into the tank and fill the upper buffer chamber with running buffer (~ 200 ml). Be careful not to distrub the contents of the wells. Check for tightness of seal. If you detect a leak from upper to lower chamber, recollect the buffer, reseal the chamber and refill. Fill the lower buffer chamber by pouring ~ 500 1300 ml of running buffer through the gap between the front gel and the front of the tank. The EcoCell will function as long as the lower buffer chamber is filled enough to cover the slot at the bottom of the cassette. Note: The volume depends on the expected Wattage during the run. Some gel systems like VarioGel create high power values during electrophoresis and heat dissipating can be achieved by using buffer volumes that the buffer level exceeds the level of the wells. For other gel types, a filled lower buffer chamber is not required. Replace the safety lid firmly making sure that the electrical connectors form a good contact. Connect the electrophoresis apparatus to the power supply and connect the power supply to the mains supply. Turn all setiings to zero before turning on the mains supply. Adjust the controls to the desired settings. Follow manufacturer s instructions. Turn on the power. Disassembly of the EcoCell Upon completion of the run, turn off the power and disconnect the cables from the power supply. Remove the safety lid and the internal running module from the tank. Loosen the screws and remove the cassette from the inner module. Rinse the cassette with distilled water and open the cassette following the gel instructions. Immediately fix, stain or transfer as desired. Empty the lower buffer chamber and rinse the components of the EcoCell with distilled water and dry them with tissue. 5

Troubleshooting Guide Problem Cause Remedy Current is zero or very low Tape left on the bottom of the cassette Connection to power supply not complete Buffer level not sufficient Remove tape Check all connections and settings Make sure the upper buffer is covering the wells of the gel. Make sure there is sufficient buffer in the lower buffer chamber to cover the slot at the bottom of the gel. Run taking longer than usual Buffers are too diluted or contaminated Upper buffer chamber is leaking Voltage is too low Check buffer recipe; re-make if necessary Make sure the inner module is frimly sealed, the gaskets are in place Set correct voltage Run is faster than normal Buffers are too concentrated or incorrect Voltage, current or wattage is set too high Check buffer recipe; dilute or remake if necessary Decrease power conditions to recommended running conditions Cannot see sample wells to load sample There is little contrast between sample well and rest of the gel Mark cassette at the bottom of the wells with marker pen prior to assembling or illuminate the bench area with a light source placed directly behind the EcoCell 6