User s Guide. VetPro 5000 Wall / Cabinet & Table Mount Dental Delivery System. For Models: Rev L (11/10/15)

Similar documents
User s Guide. VetPro 1000 Mobile Dental Delivery System. For Models:

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

OPERATION MANUAL Please read this Operation Manual carefully before use, and file for future reference.

Push-To-Set Intermittent Suction Unit (PTS-ISU) Instructions for Use

Yoke Block Instruction Manual

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Yoke Block Instruction Manual

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

Cavitron DualSelect. Introduction ENGLISH. Directions For Use. Cavitron DualSelect Dispensing System ENGLISH 1

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

Model No Product Name Handpiece Only Complete System

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

Wallmax Professional Aneroid Sphygmomanometer Model 222 User Manual

Use and Care Guide. PMU and PMU w/over the Patient. Swing Mount. Over the Patient. Side Delivery

MODEL Maverick Heavy Duty Aerosol Compressor Operator s Manual

Model ASSEMBLY and OPERATING INSTRUCTIONS

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

Blendox AII5000F Inhalation Antalgic System. User s Manual :SP-Y Series No. Version :A1. Date of Review:

Operation Manual. O2 Quickstick. Oxygen Analyzer 08.17

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

Installing ASI Umbilical Delivery Systems

AND OPERATION INSTRUCTIONS

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

PCS 340 Core Saturator : 115 Volt : 230 Volt. Instruction Manual

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

BlenderBuddy 2. Operating Manual & Instructions For Use ENGLISH R233M01 REV. A

FLUSHMATE III FLUSHMATE FLUSHOMETER - TANK SYSTEM. Owner s Service Manual. 503 Series. 503 Series

Manual. FRESH AERO OneOP Model PC (Portable Compressors) Tire Inflator. Where Imagination Meets Innovation

Installation and Operation Manual

Canis Major Wet Dental / Treatment Lift Table. For models: CMDT-45 CMDT-WS-45 CMDT-60 CMDT-WS-60. User s Guide Rev.

Freedom8 ShoeBox Compressor Manual

4-in-1 Professional Inflator Kit

Operation Manual. O2 Quickstick. Oxygen Analyzer

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

SOTR Special Operations Tactical Respirator

Interface Devices, Inc. Hydraulic Mini Mule

CSA Sample Draw Aspirator Adapter Operator s Manual

Portable Compressed CO 2 Regulator

2 CYLINDER MOBILE CART USER S MANUAL / INSTRUCTIONS

ORRA SPINNING REEL INSTRUCTION MANUAL (DRAFT)

FRESH AERO OneOP Model RC (Reservoir/tank) Tire Inflating System

MODEL 840 AIR HYDRAULIC PUMP INSTRUCTION

AIR INLINE METAL SHEAR

HAS2400 Hepa Air Scrubber

6 digital caliper with case

TABLE OF CONTENTS. INTRODUCTION to the AirVAC... 2 SAFETY INFORMATION... 3 DIMENSIONS & SPECIFICATIONS... 5 UNIT OVERVIEW... 6

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

3 Scotch-Weld Polyurethane Reactive Adhesive Applicator Replacement Part Installation Guide

M3-LED. Operator s Manual. Operator s Manual MADE IN THE USA USA

Tri-Safem Model I1 Regulator. INSTRUCTIONS and PARTS

- GAS REGULATOR - COMPACT STYLE

USER MANUAL SAVE THESE INSTRUCTIONS. 300 Held Drive Tel: (+001) Northampton, PA USA Fax: (+001) ISO Certified

Inflatable Stand Up Paddle Board Manual

PORTER INSTRUMENT COMPANY, INC.

Angled Sign Light with Shade

U S E R M A N U A L. Model: PM4300 Series SAVE THESE INSTRUCTIONS

Revolution Gurney Attachment

User Instruction Manual

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Installation Instructions Air Compressor Part # 2780, 2781

OWNER S MANUAL. Table of Contents

IMPACT WRENCH ASSEMBLY AND OPERATING INSTRUCTIONS

FLANGED TWO-PIECE BALL VALVES

ATD /8 x 50 Retractable Air Hose Reel Owner s Manual

Parts and Owners Manual

OWNER'S MANUAL. Copyright 1999 ATS - All Rights Reserved

Pressure Injection Cell Operator s Manual

INSTRUCTIONS PARTS LIST

Tsunami Breathable Air System

Nitrogen Supply System

COMPACT METAL bender 99826

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

Offset head dual chuck

TL-12 FLUSH TANK. Manual Ref. # MN-??? Polyurethane Machinery Corp. REVISION 1.0

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters

INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE. SPORTS ATTACK LLC

GETZ EQUIPMENT INNOVATORS PART No. 4G59678 CARBON DIOXIDE MINI PUMP FOR EXTINGUISHER SERVICE (Revised )

Hydraulic Punch Drivers

DLx1200, DLx1500, DLx1900, DLx2300 PULLING WINCHES. U.S. Patent Canadian Patent Model #DLx1200

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

J Air and Water Kit Instructions Part# 02584

2000 lb manual winch

Research Grade Blood Pressure Transducer User's Manual

FX IMPACT OWNER S MANUAL

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

PERSONAL AIR BREATHING UNIT

4 and 8 Station PDS Control Installation & Operators Manual

Sunset Swings By Health in Motion, LLC

Hot Tapping Machine. OPERATIONS MANUAL and OPERATING INSTRUCTIONS

DRAFT U S E R M A N U A L CAUTION. Model: 19MFA1001 Series. Federal (USA) law restricts this device to sale by or on the order of a physician.

CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1

Owner s Manual & Safety Instructions

12 Inch Barn Light. Owner s Manual

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

SSS SWEEPERS MODELS MS-31 & MS-39

SSS SWEEPERS MODELS MS-21 & MS-29

Transcription:

VetPro 5000 Wall / Cabinet & Table Mount Dental Delivery System For Models: 8001-001 8001-002 8001-003 8001-005 8001-006 8001-007 User s Guide 003-1902-00 Rev L (11/10/15)

Product Information Dealer : Date of Purchase: Model / Serial Number: Midmark Authorized Service Company: Model / Serial Number Location Calling for Service Note Model / Serial number information is required when calling for service. If service is required, contact your Midmark dealer. To contact Midmark directly: 2 1-800-Midmark (1-800-643-6275) or 937-526-3662 8:00 am until 5:00 p.m., Monday through Friday (EST) [excluding standard U.S. holidays]

Table of Contents Important Information Serial Number Location...2 Safety Symbols...4 Transportation / Storage Conditions...4 Intended Use...5 Electromagnetic Interference...5 Disposal of Equipment...5 Operation Master ON / OFF Switch...6 Flex Arm...6 Manual Shut-Off Valves...7 Pressure Regulator Valves...8 Water Toggle Switch...9 Self-Contained Water System...10 Handpieces...11 Syringe...14 Adjustment Knob Location...15 Cleaning / Maintenance Cleaning...16 Maintenance...17 Specifications Specifications...22 Warranty Warranty...23 3

Important Information Safety Symbols danger Indicates an imminently hazardous situation which will result in serious or fatal injury. This symbol is used only the most extreme conditions. warning Indicates a potentially hazardous situation which could result in serious injury. Caution Indicates a potentially hazardous situation which may result in minor or moderate injury. It may also be used to alert against unsafe practices Equipment Alert Indicates a potentially hazardous situation which could result in equipment damage. 0 Proper Shipping Orientation Maximum stacking height (Do not stack) Fragile Consult User Guide Do Not Tumble Handle With Care Keep Dry Transportation / Storage Conditions Ambient Temperature Range:...50 F to 104 F (+10 C to +40 C) Relative Humidity...10% to 90% (non-condensing) Atmospheric Pressure...700hPa (20 in.hg) to 1060hPa (31 in.hg) 4

Intended Use To provide veterinarians and/or technicians with air & water to operate handpieces, scaler, syringes, and Midmark authorized accessories during veterinary dental procedures. Electromagnetic Interference This product is designed and built to minimize electromagnetic interference with other devices. However, if interference is noticed between another device and this product: Remove interfering device from room Increase separation between product and interfering device Contact Midmark if interference persists Disposal of Equipment At the end of product life, the dental unit, accessories, and other consumable goods may become contaminated from normal use. Consult local codes and ordinances for proper disposal of equipment, accessories and other consumable goods. 5

Operation Master ON / OFF Switch The master on / off switch must be ON to operate the delivery system. ON OFF Flex Arm Master ON / OFF Switch To avoid injury to the patient or staff, the flex arm can be locked to prevent accidental movement. (The flex arm will still move upward when locked.) To Unlock / Lock Flex arm... A) Turn power on. Allow system to pressurize. B) Push up release button to disengage lock and lower to desired height. It may be necessary to move head upwards slightly before lowering. Note: Flex arm lock buttons will not work unless the system is pressurized. Lock Release Button 6

20 0 40 60 80 Operation Manual Shut-Off Valves - (Only for Units with Junction Box) The manual shut-off valves allow you to stop the air and/or water supply at the point of input to the dental unit. This can be done during extended periods of no-use (ex. vacation, holidays, etc.), or in the event of a malfunction. To shut off water to Dental Unit... Rotate water shut-off valve knob clockwise. City Water Regulator Valve Water Bottle Regulator Valve Water Shut-Off Valve Air Shut-Off Valve 2 3 4 1 5 0 6 Air Regulator Valve 7 100 To shut off air to Dental Unit... Rotate air shut-off valve knob clockwise. 7

Operation Pressure Regulator Valves - (Only for Units with Junction Box) The pressure regulator valves allow you to adjust the air and water pressure that is supplied to the dental unit. Recommended Settings City Water Regulator Valve...30 PSI Air Regulator Valve...80 PSI Water Bottle Regulator Valve...30 PSI (Do not adjust!) Decrease Increase Adjustment Knob Unlock Lock To adjust regulator... A) Pull knob up to unlock. B) Rotate knob until desired pressure is displayed on gauge. C) Push knob down to lock. Equipment Alert The dental unit has been designed to operate at the recommend settings. Setting the pressure higher / lower than recommended may result in damage to the equipment or diminished performance. 8

Operation Water Toggle Switch The water toggle switch allows you to choose the water source for the delivery system. You may use either City water (tap water), or water from the self-contained water system bottle. Location of the switch is shown below. Wall / Cabinet Mount Self-Contained Water System City Water Table Mount 9

Operation Self-Contained Water - System The self-contained water system allows you to control the quality of water used in your delivery system. It also provides a means for disinfecting the system s internal tubing. Caution Residual air pressure may cause the water bottle to fall and/or bottle contents to spill or spray if not released. Before you begin... A) Turn master switch OFF. B) Press syringe air button until all residual air pressure is released. OFF Wall Mount Shown To fill the Self -Contained Water System... A) Unscrew water bottle. B) Fill bottle with water. (Distilled Water Is Recommended) C) Be sure gasket is in place. D) Screw bottle into mounting cap. Note: If gasket is not installed properly, you will hear a hissing when the system is turned ON. Water bottle should be checked in between each patient and filled if necessary. Gasket 10

Operation Handpieces Before you begin... Turn Master ON / OFF switch ON. Move Water Toggle Switch to desired setting. Step 1: Pull handpiece forward. Step 3: Press foot control pedal to deliver drive air to the handpiece. WET DRY Step 2: Select Wet or Dry operation using the foot control toggle switch. Note: The blue dot indicates Wet position. 11

Operation Handpiece Care Prophy Angle To Change Prophy Angle... A) Rotate chuck to the right to unlock. B) Install Prophy angle, turn chuck release ring left to tighten. Safety Shaft To Change Bur in High Speed Handpiece... A) Push button on back of handpiece and pull the bur out. B) Push bur into handpiece. (The shank will only go in half-way) C) Then push button on back of handpiece and push the bur in until shank is all the way in. Note: Friction grip burs (FG Style) are designed so that the entire straight portion of the shaft should be inside the chuck of the handpiece. You should only see the tapered portion of the bur if installed properly. Push Bur Into Handpiece Finish Sliding Bur Into Handpiece Push Button Shaft Inside Handpiece This Portion of the Bur Should be Inside the Handpiece 12

Handpiece Care Install handpieces. Swivel Coupler Connection Line up components properly to prevent damage resulting in hand piece failure. Lightly spray the exposed o-rings with one step conditioner. Tighten coupler firmly with wrench. Handpiece Connection 13 Equipment Alert Complete manufacture s instructions for Infection Control / Sterilization found in the documentation included with the handpieces. Failure to do this will cause premature failure of handpieces.

Operation Syringe This page shows operation and adjustment for a standard 3-way syringe. For air spray... Press air button. Before you begin... Turn master ON / OFF switch ON. Move water toggle switch to desired setting. For water stream... Press water button. For water spray (mist)... Press air and water buttons. Air Button Water Button To adjust air spray pressure and water spray pattern... Rotate syringe air adjustment knob as necessary. Syringe Water Adjustment Knob Syringe Air Adjustment Knob To adjust water steam pressure and water spray pattern... Rotate syringe water adjustment knob as necessary. 14

Operation Adjustment Knob Locations Front View Pressure Indicator Pressure Gauge [Drive Air] Coolant Water Scaler Adjustment Coolant Water Flush Button Bottom View Coolant Air Syringe Water Syringe Air 15 Drive Air

Cleaning Note Every veterinary practice setting is different and no one disinfectant is the best choice for every facility. There are several organizations educated in disinfection procedures. Refer to web sites of accredited sources that can assist veterinary personnel in choosing what is best for their practice. Listed below are a few of the sites. Organization for Safety & Asepsis Procedures http://www.osap.org Dept. of Health & Human Resources Centers for Disease Control & Prevention (CDC) http://www.cdc.gov Read carefully DA148100i When using disinfectants... Carefully read the product label and directions for use. Do not exceed the dilution rate. Equipment Alert Refer to handpiece manufacturer for suggested cleaning procedures. 16

Maintenance At the beginning of each work day... Fill water bottles with fresh distilled water. Flush handpieces. Distilled water is not mandatory. However, water must meet requirements for drinking. To Flush Delivery System... A) Remove all handpieces that use water. B) Open water needle valve. C) Turn foot control toggle switch to WET. D) Hold end of tubing over a container and press foot control for 30 seconds. Then press and hold flush button for 30 seconds. Repeat (step D) for all handpieces. E) Press and hold syringe buttons (air & water) for 30 seconds. F) Install newly disinfected handpieces. G) Refill water bottle. Between each patient... Remove disposable tips, instruments, etc.. Flush delivery system. Clean handpieces and scaler per manufacturers instructions. Fill water bottles. 17

Maintenance - continued At the end of each day... Bleach flush delivery system and empty water stem. Clean system. BLEACH Equipment alert Do not use colored/scented bleach, or concentrations greater than recommended. Do not leave bleach solution in delivery system longer than 30 minutes, it could damage the delivery system. To Bleach Flush Delivery System... A) Remove all handpieces that use water. B) Remove water bottles and fill with 9 parts water and 1 part bleach. C) Open water needle valve. D) Hold end of tubing over a container and press foot control for 30 seconds. Then press and hold flush button for 30 seconds. Repeat (step D) for all handpieces. E) Press and hold syringe buttons (air & water) for 30 seconds. F) Leave bleach solution in delivery system for 10-20 minutes, then remove / empty / rinse water bottles. G) Fill water bottles with fresh water and repeat steps C thru E until bleach odor is gone. H) Install newly disinfected handpieces. I) Empty water bottles. 18

Maintenance - continued To Clean System... A) Disinfect handpieces according to manufacturer s instructions. B) Wipe down the WHIP head and operatory equipment with disinfectant. Note: Refer to Cleaning page in this guide. Read carefully DA148100i Air / Oil Separator Periodically, check the gauze in the air / oil separator cup. When gauze is saturated it must be replaced. Before you begin... Turn master ON / OFF switch OFF. Gauze Cup To clean the air / oil separator cup... A) Unsnap cup. B) Dispose of saturated gauze. C) Disinfect cup. D) Install new gauze, then reinstall cup. 19

0 0 20 0 2 1 0 40 4 3 60 4 5 7 60 5 7 6 100 80 80 Maintenance Regulator Valve Filters (Only for Units with Junction Box) The air and water pressure regulator valves each have a sediment filter to prevent debris from entering the system. To maintain proper air and water flow, these filter should be replaced approximately every three months. Before you begin... Turn off water & air supply to the dental unit by closing both manual shut-off valves. 6 Step 2: Unscrew retainer nut. Remove filter. Retainer Nut 100 Filter Step 3: Install new filter. Secure with retainer nut. Note: Install the filter & retainer nut with the ridged side up (as shown). Filter Cap Step 1: Unscrew filter cap. Note: Use 9/16 wrench. Step 4: Reinstall filter cap. Note: Use 9/16 wrench. 20

Maintenance - continued Flex Arm - Pivot Point Adjustment If the flex arem has too much play or is not moving freely, adjust the pivot point, set screws as necessary. To Adjust Arms at Pivot Points.. If arms have too much play, tighten them (Clockwise). If they do not move freely, loosen them (Counter-Clockwise). Pivot Points Wall Mount Shown Remove Bearing Cover to Access 4th Pivot Point, Set Screw Pivot Point 21

Specifications Water Module Reservoir One - 1 Liter City Water Toggled with Reservoir Pressurized System 30-50 PSI Aseptic Non-Retracting HPC Coolant Handpiece Flush System Manual Recommended Pressure Settings (Junction Box) City Water Regulator Valve 30 PSI Air Regulator Valve 80 PSI Water Bottle Regulator Valve 30 PSI Electrical Voltage 115 VAC Circuit Breaker Protection 15 amps Frequency 60 Hz warning Equipment not suitable for use in the presence of a flammable anesthetic mixture. warning The Acteon Newtron LED scaler complies with current electromagnetic compatibility standards. However, it must not be used by or on those with cardiac stimulators or other active implants unless adequate electromagnetic interference shielding is present. Check with a cardiologist to verify the EMI shielding capabilities of the implant. See enclosed Newtron LED manual for further advisories. 22

Limited Warranty SCOPE OF WARRANTY Midmark Corporation ( Midmark ) warrants to the original purchaser its Exam Room Casework, Veterinary products and components (except for components not warranted under Exclusions ) manufactured by Midmark to be free from defects in material and workmanship under normal interior use and service. Midmark s obligation under this warranty is limited to the repair or replacement, at Midmark s option, of the parts or the products the defects of which are reported to Midmark within the applicable warranty period and which, upon examination by Midmark, prove to be defective. APPLICABLE WARRANTY PERIOD The applicable warranty period, measured from the date of delivery to the original user, shall be as follows: The VetPro 5000 unit is warranted against defect in material and workmanship for a period of two years from the time of delivery. DENTAL PRODUCTS are warranted against defect in material and workmanship for the period indicated below from the time of delivery: a) 2 years for all products and components (except for the periods in b through d). b) KINK-VALVE module carries a 10 year warranty. c) Accessories not manufactured by Midmark are excluded (i.e. Fiber optic systems, Scalers, Handpieces, etc.). d) Replacement parts and accessories carry a 90 day warranty EXCLUSIONS This warranty does not cover and Midmark shall not be liable for the following; (1) repairs and replacements required because of misuse, abuse, negligence, alteration, accident, freight damage, or tampering; (2) changes in color caused by natural or artificial light; (3) products which are not installed, used, and properly cleaned as required in the Midmark written Installation and or Installation/Operation Manual applicable for this product; (4) products considered to be of a consumable nature such as light bulbs and surge suppression product; (5) accessories or parts not manufactured by Midmark; (Any warranties on these items are extended directly by the manufacturer of these items to the original purchaser. Information on these manufacturers warranties will be enclosed with the applicable products. Also, Midmark will furnish copies of any of the warranties extended by any such manufacturers upon request.) (6) specially manufactured products; (7) damage caused by animals; (8) charges by anyone (including Midmark s authorized dealers) for adjustments, repairs, replacement parts, installation, or other work performed upon or in connection with such products which is not expressly authorized in writing in advance by Midmark. EXCLUSIVE REMEDY Midmark s only obligation under this warranty is the repair or replacement of defective parts. Midmark shall not be liable for any direct, special, indirect, incidental, exemplary or consequential damages or delay including, but not limited to, damages for loss of profits or loss of use. NO AUTHORIZATION No person or firm is authorized to create for Midmark any other obligation or liability in connection with the products. THIS WARRANTY IS MIDMARK S ONLY WARRANTY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. MIDMARK MAKES NO IMPLIED WARRANTIES OF ANY KIND INCLUDING ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT OF DEFECTIVE PARTS. 23

24