Work Method Statement. Prepared for: The Bolton NHS Foundation Trust Prepared by: Mark Fentiman Date:

Similar documents
Risk Analysis and Hazard Reduction Report V1.0

In Vessel Composter Installation & Commissioning Manual

Walk in Modular Material Transfer Chamber Including Integration of a Bioquell Clarus L2 hydrogen peroxide vapour (HPV) generator

The primary purpose of laboratory fume hoods is to keep toxic or irritating vapors out of the general laboratory working area.

Laboratory Preparedness Checklists for Advanced Planning, Preparing to Close & Safe Re-Entry

Using Vaporized Hydrogen Peroxide

A4s Operation Manual

Technical Data Sheet MF010-O-LC

Appendix A: Induction check list

6800 Maintenance Instruction System Flush Procedure

Toolkit for safe Use of Microbiological Safety Cabinets(MSC s)

6900 Maintenance Instruction System Flush

A4 Operation Manual. Fig.1-1 Controller Socket Diagram

Transfer Procedures. By the end of this chapter, you will be able to: The Transfer Process. Chapter 12

Western Sydney University Safety Inspection Checklist - Laboratory Environments

Roller AC Servo System

HONG KONG COLLEGE OF ANAESTHESIOLOGISTS TECHNICAL GUIDINES RECOMMENDATIONS ON CHECKING ANAESTHESIA DELIVERY SYSTEMS

CircuFlow Quick Setup Guide

Laboratory Self Inspection Checklist LAB01

Approval Block. Prepared by: Signature Date. Evan Parnell 08 NOV Reviewed by: Signature Date. Approved by: Signature Date

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

Laboratory and Satellite Rodent Housing

BI-680 Online Dissolved Oxygen Controller Instruction Manual

HOW WISE TECHNOLOGY WORKS INFICON Protec P3000 sensor powered by Wise Technology, consists of an evacuated gas cell covered by a quartz membrane.

Completed by: Anthony Jones (BE Design Laboratory Manager) Staff/Student number: School/Unit: BE Design Laboratory. Current version: V_01

RAM 4021 Operation Manual

Laboratory Safety Training. Environmental Health and Safety

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

Negative Pressure Wound Therapy

User manual CF8-D/W-IN

Pulmonex II Training Presentation

EHS Workplace Inspection Checklist (Ref. SOP QMS-080; EHS-010)

Reflow Oven HHL3000 INSTRUCTION MANUAL POHUA - jedyny autoryzowany przedstawiciel w Polsce

Recommendations on Checking Anaesthesia Delivery Systems

RAM 4021-DPX Operation Manual

Protec P3000 (XL) Helium Sniffer Leak Detector

Using the UltraRAE. Firmware 2.35

Risk Assessment for: Fume cupboards

OBJECTIVE 22: EMERGENCY WORKERS, EQUIPMENT, AND VEHICLES - MONITORING AND DECONTAMINATION

RH800 & 2000 BASIC OPERATIONS

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

HYPOXIC AIR FIRE PREVENTION SYSTEM TECHNICAL SPECIFICATION

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

ACV-10 Automatic Control Valve

BOC: Living healthcare. Manual. LIV IQ BOC Integrated Valve with digital display portable delivery system for Medical Oxygen. BOC: Living healthcare

Astral in AirView: Improving patient care through connectivity. ResMed.com

0RGHO /6 /6/6/6 /LTXLGÃ/HYHOÃ(TXLYDOHQWV

Air Plus User Manual

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

MEDIANA HEARTON AED A15. Mediana Automated External Defibrillator A15

Equipment Operating Procedure Glove Box

SOP for use of the SX19 Stopped-Flow Instrument

How to calibrate the formaldehyde sensor within a PPMonitor Wireless Unit:

LABORATORY FUME HOOD SPECIFICATION AND MAINTENANCE PROGRAM

Astral in AirView: Improving patient care through connectivity. ResMed.com

SUGGESTED POLICY FOR THE MONITORING OF THE CLEANING EFFICIENCY OF AN ULTRASONIC CLEANERS( SONIC & TOSI) WEEKLY

Sedan Range. Evaporative Loss System Check Clarified Procedure

USER MANUAL OPERATION AND THE USE OF A CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM

Instructions in the Use of Radiation Protection. Equipment and Radiation Measuring Instruments by. Disaster Response Personnel in a Nuclear Emergency

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

Appendix A. RMM #500 Designated Substances Control Program. Designated Substance Assessment Form RECORD OF DESIGNATED SUBSTANCE ASSESSMENT

Columbus Instruments

Anatomy Lab Safety Plan

Stand-Alone Bubble Detection System

A. Evaluation of the written program

PERSONAL AIR BREATHING UNIT

ShellPa. Standard Mechanical Cell Stretch System Model No: NNMS Serial #: User Manual

Maintenance handbook

1. The laboratory supervisor must enforce the institutional policies that control access to the laboratory.

Validation of a Neutral Pressure Isolation Room

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Nuclear Associates

1020 Industrial Drive, Orlinda, TN fax

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

Digital Melting Point Apparatus

Digital Vacuum Regulator

Series Environmental Chambers

Biological Safety Cabinet Guidelines

In Response to a Planned Power Outage: PPMS EverCool II Shut Down and Re-start Procedure

Instruction Manual Otoflash G171 UV-flash-device for Light Curing

Choosing and Installing Microbiological Safety Cabinets

Application Note 13: Electron Microscope Decontamination

Keele University Institute for Science and Technology in Medicine. Standard Operating Procedure. Title: Transportation of Human Tissue

Operating instructions Electrical switching facility pco

Laboratory Mortar Mixer (Testing)

Cavitron DualSelect. Introduction ENGLISH. Directions For Use. Cavitron DualSelect Dispensing System ENGLISH 1

OptiCare. Optimising patient care

UNIVERSITY OF ROCHESTER MEDICAL CENTER

OPERATION MANUAL NTF-15

User Manual GRI- 1500Li

H 2 O 2 Bio-Decontamination and Aseptic Transfer of Heat Sensitive Materials Sergio Mauri, Director, Global Marketing and Business Intelligence

Exeter Clinical and Health Research

MB-SP Series Solvent Purification System

STS PECVD Instructions

Contractor Control Procedures. Contractor Control Procedures. Working Together. November Borders College 24/11/2014.

BIOSAFETY SELF AUDIT PRINCIPAL INVESTIGATOR/PERMIT HOLDER: CONTAINMENT LEVEL: 1 2 (Shaded) RISK GROUP: 1 2 AUDIT TO BE COMPLETED BY (DATE):

Transcription:

Work Method Statement Prepared for: The Bolton NHS Foundation Trust Prepared by: Mark Fentiman Date: 06.03.2014

Detailed Work Plan The Bolton NHS Foundation Trust Date: 06.03.2014 1 Contents: 1. The Deprox HPRD system: 2. Treatment Parameters 3. Process Characteristics 4. Quality and Assurance 5. Validation 6. Method Statement a. Process Map b. Work Flow Plan c. DEPROX In Use Protocol 7. Key Contact Details

Detailed Work Plan The Bolton NHS Foundation Trust Date: 06.03.2014 2 1. The Deprox HPRD system: From the outset DEPROX bio-decontamination system was designed to be used by hospitals in their efforts to reduce environmental contamination and associated patient infection. The DEPROX is, by design, simple to use with risk of operator error or hazard, minimized where ever possible. From using self calculating software to low concentration chemical formulations the risks associated with using the DEPROX are significantly reduced from that of traditional vaporising decontamination processes. The DEPROX is a calibrated vapour generating device which combines the use of high frequency ultrasonic and chemical indicators. The DEPROX will ensure a homogenous diffusion of vaporized Hydrogen Peroxide vapour around an enclosed space. The Hydrogen Peroxide solution used in this process is Deproxin, a 4.9% Hydrogen Peroxide solution containing, 0.001% silver nitrate solution (See Deproxin Safety Data Sheet). This process is validated to deliver a 6 log reduction across a broad spectrum of organisms. Site specific validation is agreed with suitable qualified persons within the procuring organization before commencement of the process. This technology is used by hospitals around the world and the routine use of it has been proven to reduce infection acquisition by patients. The DEPROX is now recognised by leading hospitals around the world to this end.

Detailed Work Plan The Bolton NHS Foundation Trust Date: 06.03.2014 3 2. Treatment Parameters: In order to carry out an effective decontamination cycle the DEPROX requires certain operating parameters: Minimized absorbent materials within the space although everything has a natural absorbency level irrespective of its construction, it is beneficial to remove highly absorbent materials such as textiles, paper and other porous materials. Although the presence of these will not compromise the efficacy to other surfaces, they will increase the treatment and deactivation times. Exposed surfaces the DEPROX is a vaporizing process and relies on the movement of vapour and gaseous hydrogen peroxide around a space to treat the surfaces within it. Directly adjacent surfaces, i.e. two flat surfaces touching, will not be easily penetrated by the process and could remain untreated. Ambient and surface temperatures of between 10 C and 35 C to ensure capacity for the vapour in the enclosed air volume to reach the required concentration, without reaching saturation or dew point. Ambient humidity of between 15% and 70% - to ensure capacity for the vapour in the enclosed air volume to reach the required concentration, without reaching saturation or dew point. Contained air volume to effectively treat the surfaces contained within the space, the DEPROX requires a contained air volume. This involves sealing ventilation and potential leak points to ensure the air volume remains the same throughout the process. The DEPROX bio-decontamination system is not a cleaning process. On this basis all areas treated with the DEPROX must be cleaned, prior to the decontamination cycle. In this context cleaning would require: The removal of organic matter The removal of adhesive residues and films The removal of dust and visible dirt Free from waste material Free from loose or compromised surfaces

Detailed Work Plan The Bolton NHS Foundation Trust Date: 06.03.2014 4 3. Process Characteristics: The DEPROX bio-decontamination system is designed to deliver a log 6 reduction to all surfaces in the affected area through a method of calibrated vapour generation and environmental monitoring. The treatment cycle is a standardised to ensure a consistent efficacy in all environments. This cycle, which is controlled and monitored computationally onboard the DEPROX system, follows the below steps: 6.System Reset The DEPROX resets readiness for the next process. 1.Pre-Start Checks DEPROX Equipment monitors environmental parameters to check for suitability. Approx 3 minutes 5.Deactivation The DEPROX monitors the environmental parameters until deactivation is complete and safe to re-enter. 2.Start Cycle Following setup and preparation of the area in line with protocol, the Operator starts cycle remotely. Approx 2 minutes. 4.Surface Treatment The DEPROX maintains the concentration in the environment for 90 minutes ensuring dwell time and treatment of all surfaces 3.Vapour Diffusion The DEPROX generates the vapour until the required concentrations have been achieved. Between 0-35 minutes

Detailed Work Plan The Bolton NHS Foundation Trust Date: 06.03.2014 5 Process Characteristics (cont d): During the DEPROX decontamination process, the Process Monitor placed outside the room will provide visual indication to the operator and any personnel in adjacent areas as to the current status of the process. Pre-Start Process Monitor will show a solid GREEN light Start Cycle Process Monitor will show a solid GREEN light and flashing RED light Vapour Diffusion Process Monitor will show a solid RED light Surface Treatment Process Monitor will show a solid RED light Deactivation Process Monitor will show a solid RED light and flashing GREEN light Reset System the Process Monitor will show a solid GREEN light Precautions the DEPROX bio-decontamination system will take before, during and after the process to ensure safe and effective treatment of the environment, include: Temperature fluctuations above 35 C or below 10 C Humidity fluctuations above 15% or below 70% H2O2 level increase or decrease from computational model In the event of any of the above parameters being breached, the DEPROX will register fault mode and move into a deactivation cycle.

Detailed Work Plan The Bolton NHS Foundation Trust Date: 06.03.2014 6 4. Validation The DEPROX bio-decontamination system vaporizes the Hydrogen Peroxide solution using high frequency ultrasonic s. The benefit of this method is the efficient generation of vapour of a selected size to effectively defuse throughout the space and decontaminate the surfaces in the affected environment. Hygiene Solutions will agree with suitably qualified persons before commencing the process the preferred method of validation. Recommended methods include: Surface sampling before and after for specific organisms subject to prior agreement with suitably qualified persons regarding surfaces, location, organisms and laboratory protocol. Details will be recorded onto the Validation Record and corresponding Floor Plan for future reference and audit. Surface seeding with sampling before and afterwards for specific organisms subject to prior agreement with suitably qualified persons regarding surface seeding, location, organisms and laboratory protocol. Details will be recorded onto the Validation Record and corresponding Floor Plan for future reference and audit. Biological indicators of surrogate organisms inoculated onto test surfaces subject to prior agreement with suitably qualified persons regarding location, organisms and laboratory protocol. Details will be recorded onto the Validation Record and corresponding Floor Plan for future reference and audit. Chemical indicators to indicate vapour movement and space penetration - subject to prior agreement with suitably qualified persons regarding location. Details will be recorded onto the Validation Record and corresponding Floor Plan for future reference and audit.

Detailed Work Plan The Bolton NHS Foundation Trust Date: 06.03.2014 7 The DEPROX carries on board chemical indication for the purpose of the treatment cycle and designed safety features. When in routine use within the general hospital setting, as part of an enhanced cleaning programme, this would become the usual validation method unless under exceptional circumstances.

Detailed Work Plan The Bolton NHS Foundation Trust Date: 06.03.2014 8 Work Method Statement: This is a Method Statement specific to the Deprox HPRD system within an NHS Acute Trust: Action Description 1 Remove absorbent materials within the space such as linen, paper towels, tissues, curtains, gowns and any other porous materials. Ensure hospital protocol is followed 2 Ensure the room has been manually cleaned to remove gross soiling, dust and dirt and ensure all surfaces within the room are dry. Ensure hospital protocol is followed. 3 Remove all items that may have been used in patients ie: catheters, thermometers etc 4 Remove any waste from the bins. 5 Remove any food items, drinks water jugs etc. 6 Turn any mattresses in the area on to their side.

Detailed Work Plan The Bolton NHS Foundation Trust Date: 06.03.2014 9 Action Description 7 Ensure bins and dispensers are opened. 8 Turn chair cushions on to their side. 9 Hold bathroom door open with a stool/chair/doorstop etc. 10 Ensure cabinet drawers, bedside cabinets and cupboards are open. 11 Close all windows. 12 Seal the ventilation in the area to be treated using the Ventilation Restriction Kit.

Detailed Work Plan The Bolton NHS Foundation Trust Date: 06.03.2014 10 Action Description 13 Seal the fire alarm sensors in the area to be treated using the Fire Detector Cap Kit 14 Place Decontamination in progress sign on all entrances into the area that you are going to run the process in. Ensure that these are put in a visible place to any persons that may approach the entrances. 15 Operator informs senior person in surrounding area i.e. Senior Nurse of the proposed process and potential hazards: a. Process description b. Process cycle times and affected areas c. Hazards and risk reduction d. Protocol in the event of i. Fire alarm ii. Process termination iii. Vapour leakage 16 Ensure ward staff are informed of the process taking place, who they should call in the event of a suspected issue and when the process is likely to finish 17 Operator places the Deprox HPRD system in the centre of the room to be treated and secure wheels using the brakes. 18 Operator unhooks the process analyser from the rear of the machine and plugs the cable into the yellow socket on the front of the machine.

Detailed Work Plan The Bolton NHS Foundation Trust Date: 06.03.2014 11 Action Description 19 Operator positions the process analyser away from the Deprox System. 20 Operator unhooks the process monitor from the rear of the machine and plugs the cable into the blue socket on the front of the machine. 21 Operator plugs the mains plug into a convenient socket. 22 Operator presses the start cycle button the the control panel, both the red and green lights should be Illuminated on the process monitor.

Detailed Work Plan The Bolton NHS Foundation Trust Date: 06.03.2014 12 Action Description 23 Check the Deprox HPRD system for Deproxin requirement. If a new Deproxin Cartridge is required: 1. Secure cap of remaining Deproxin cartridge 2. Remove empty Deproxin cartridge from main Deprox unit by holding the indented cartridge neck and pulling upwards from the Deprox main unit. Dispose of directly into waste bin (suitable for disposing in ordinary waste or recycling as PET). 3. Take new Deproxin cartridge by holding the indented cartridge neck and insert directly in to refill port on main Deprox unit. 4. Push down firmly to engage with extraction spears and release lid to first safety notch. The Deprox HPRD unit will now register the new cartridge and prepare for the decontamination cycle to start. 24 When the Deprox HPRD system is ready to start, double check the room and its contents are ready and move out of the room.

Detailed Work Plan The Bolton NHS Foundation Trust Date: 06.03.2014 13 Action Description 25 Complete the Operator checklist on the reverse of the Decontamination in progress sign to ensure that all areas have been completed appropriately. 26 Close and seal the exit doors and secure with double door bar. Clearly mark the start time and estimated finish times on the Decontamination warning sign. 27 Turn the key once in the process monitor outside the room. THE DEPROX HPRD SYSTEM IS NOW RUNNING DO NOT RE- ENTER THE ROOM. a. The DEPROX system starts emitting vapour into the space. The Process Analyser detects a change in the environmental parameters and monitors a rise to the required predetermined level of H2O2 vapour within the space. During this phase the Process Monitor outside the room will display a solid RED light to indicate to personnel in adjacent areas of the process status and potential hazards.

Detailed Work Plan The Bolton NHS Foundation Trust Date: 06.03.2014 14 2. a. On reaching the required level of H2O2 vapour within the space, the DEPROX with terminate the initial vaporisation cycle and maintain a consistent H2O2 vapour level within the space for the duration of the surface treatment cycle. During this phase the Process Monitor outside the room will display a solid RED light to indicate to personnel in adjacent areas the process status and potential hazards. b. On completing the surface treatment cycle the DEPROX starts the deactivation process, reducing the H2O2 vapour level back to within the EWEL (European Work Exposure Limit) of >1ppm. During this phase the Process Monitor outside the room will display a solid RED light and a flashing GREEN light to indicate to personnel in adjacent areas the process status and potential hazards. c. On completion of this phase the DEPROX system automatically resets in preparation for the next cycle. At this point the Process Monitor outside the room will display a solid GREEN light to indicate to personnel in adjacent areas the process status.

Detailed Work Plan The Bolton NHS Foundation Trust Date: 06.03.2014 15 Action Description 28 When the process is finished the Process Monitor outside the room will show a solid GREEN light. 29 Unlock the door and remove signage and sealant tape. 30 Check that the process has completed successfully on the main Deprox display unit. 31 Operator switches off the wall socket and unplugs the Deprox System.

Detailed Work Plan The Bolton NHS Foundation Trust Date: 06.03.2014 16 Action Description 32 Operator unplugs the process monitor and process analyser and re-stows the monitors onto the rear of the Deprox unit. 33 Remove the packed Deprox HPRD unit from the room and move to the dedicated store room. 34 Open windows to ventilate room 35 Remove Ventilation Restriction covers from all ventilation. 36 Remove any fire detector covers. 35 Remove sealing from doors and windows 34 Operator Informs senior ward staff that the process is complete.

Detailed Work Plan The Bolton NHS Foundation Trust Date: 06.03.2014 17