SPECIFICATIONS FOR THE PURCHASE OF FIFTY-EIGHT (58) SELF-CONTAINED BREATHING APPARATUS (SCBA)

Similar documents
Grayslake Fire Protection District Request for Self-Contained Breathing Apparatus (SCBA) Bid

The McHenry Township Fire Protection District (MTFPD) invites interested and qualified parties to submit a request for proposal for SCBA.

Bradford Fire Department. Seeks Bids for the Purchase of Self Contained Breathing Apparatus and Related Equipment GENERAL SPECIFICATIONS WARRANTY

City of Minot Specifications SCBA

CITY OF ST. CHARLES REQUEST FOR PROPOSAL SELF-CONTAINED BREATHING APPARATUS

REQUEST FOR PROPOSAL RFP FD SCBA. Closing Time: August 23rd, 2018 at 2:00pm Local time

SCBA Bid Specifications

BID SHEET. Project: Respiratory Equipment for Fire Department Plain Township Resolution F2 Company Name:

CITY OF FENTON FIRE DEPARTMENT 205 E. Caroline St. Fenton, MI Self Contained Breathing Apparatus (SCBA) Replacement Project October 2018

Purchaser Specification Requirements for SCBA Gear

Dräger PSS 7000 SCBA Self-Contained Breathing Apparatus

Dräger PSS 5000 (NFPA 2013 Edition) Self-Contained Breathing Apparatus

CITY OF VANCOUVER ADMINISTRATIVE REPORT

Notice July 2, 2018 City of Greenville Greenville, Michigan Department of Public Safety. To Bidders SELF CONTAINED BREATHING APPARATUS

NOTICE TO Bidders. Sealed bids subject to the conditions contained herein will be received until 3:00p.m. on October

REVISED ATTACHMENT 2 BID PRICING FORM

Watertown City Council

Piped Air SCBA Refilling System Standard

NIOSH Task Number 18388

Sperian Warrior SCBA

Bid Specifications for NFPA 1981, 2013 Edition. Self-Contained Breathing Apparatus. General Requirements

BUSINESS OF THE CITY COUNCIL CITY OF MERCER ISLAND, WA

QUESTIONS & ANSWERS AIR-PAK X3 PRO QUESTION. What facepieces are approved for use with the Air-Pak X3 Pro SCBA? ANSWER

City of Pigeon Forge Fire Department Tony L. Watson, Chief

Air & Gas Technologies, Inc. 42 Industrial Drive Cliff Beach, NJ

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 11 Specifications and Overview Revised

QUESTIONS & ANSWERS AIR-PAK X3 PRO QUESTION. What facepieces are approved for use with the Air-Pak X3 Pro SCBA? ANSWER

SABRE AIRLINE BREATHING APPARATUS

Course Firefighter I. Unit II Safety and Orientation

REQUEST FOR BIDS For Intake Tunnel Project Bid Notice

FIRE- FIGHTING AT THE NEXT LEVEL

ExtendAire TM II. Intermediate Pressure Accessory Kit USER INSTRUCTIONS

2.1 STS Crane Glass Pricing - Savannah Crane # Drawing # Item # Type Of Glass Cost. Sav LV50:112-L1 1. Sav LV50:112-L1 2

CITY OF HAYS, KANSAS BID PROPOSAL REQUEST FOR ONE (1) ZERO TURN, 100 INCH LASTEC 3300 ARTICULATING MOWER TABLE OF CONTENTS

SE40. positive pressure demand respirator for emergency response in CBRN environments

City of Oneonta. Oneonta Fire and Rescue Servic

Dräger PSS 7000 SCBA (NFPA 2013 Edition) Self-Contained Breathing Apparatus

M7XT Parts List PARTS LIST. TAL 1504 (L) Rev. 2 MSA 2015 Prnt. Spec (I) Mat Doc

Strong Protection Firefighters Can Count On.

RAPID INTERVENTION CREW (RIC) Bag

TABLE OF CONTENTS PART 11 - FIREFIGHTING

The SCBA shall maintain all NIOSH standards with any of the following types of cylinders listed as provided by the SCBA manufacturer.

AirHawk SCBA. Now available with MSA s Advantage 4000 Facepiece

COUGAR. Self-Contained Breathing Apparatus (SCBA) Product Specification Sheet

Dräger PSS 3000 Self-Contained Breathing Apparatus

The SCBA shall maintain all NIOSH standards with any of the following types of cylinders listed as provided by the SCBA manufacturer.

SWIM POOL MANAGEMENT City of Blue Springs, Missouri

Common Discrepancies Uncovered on ADCI Diving Contractor & Training Program Audits

Australian/New Zealand Standard

PPE Refresher Using your SCBA

NFPA 2013 EDITION SCOTT PRODUCTS SCOTT AIR-PAK AND ACCESSORIES

MSA G1 SCBA. Pre-production images and information provided, production model may vary.

WARRIOR CHEMICAL, BIOLOGICAL, RADIOLOGICAL, AND NUCLEAR (CBRN) SELF-CONTAINED BREATHING APPARATUS (SCBA)

Wide-view Ultra Elite Facepiece with Kevlar SpeeD-ON Head Harness

PERSONAL AIR BREATHING UNIT

MSA G1 SCBA. Pre-production images and information provided, production model may vary.

POLICY AND PROCEDURE DIVISION OF FIRE AND RESCUE SERVICES

Unit 3.3 Personal Protective Equipment (Core)

Work Horses of the Breathing Air Industry

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

INSTRUCTION MANUAL FOR EBA MINUTE SELF-CONTAINED SELF RESCUER (SCSR) Manual Number: NH13747 Revision: A, ECN 2384 September 7, 2001

A. Evaluation of the written program

MODEL CALIBRATION GAS DELIVERY SYSTEM

Regional SCBA Purchase Bid Specifications

Checklist for care of Respirators

City of Palo Alto (ID # 8314) City Council Staff Report

Town of Wells Vehicle Bid Package

CONTOUR 300/500 SELF CONTAINED BREATHING APPARATUS

Dräger PSS 4000 Self Contained Breathing Apparatus

Alabama Fire College Rapid Intervention Crews Instructional JPR Verification Sheet

Bids received after the appointed date set for receipt will be returned unopened.

Australian/New Zealand Standard

National Personal Protective Technology Laboratory

Committee Input No. 35-NFPA [ Chapter 1 ] Submitter Information Verification. Committee Statement

SALEM TOWNSHIP FIRE DEPARTMENT RESPIRATORTY PROTECTION PROGRAM

BID SPECIFICATIONS. Tablets FOR. Hardeman County Schools

ST53SD. Self Contained Breathing Apparatus. User Manual

GGG-M-125/3A September 20, 1982 SUPERSEDING GGG-M-125/3 March 28, 1975 FEDERAL SPECIFICATION

ASSE International Product (Seal) Listing Program

Town of Berwick Maine. Request for Proposal Ambulance Services. July 1, June 30, 2014

FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS

3 Choosing the Right Respirator

Donning Personal Protective Equipment

HONG KONG COLLEGE OF ANAESTHESIOLOGISTS TECHNICAL GUIDINES RECOMMENDATIONS ON CHECKING ANAESTHESIA DELIVERY SYSTEMS

Product Information News

TROUSERS - Approved colors only (Dark navy, black, tan)

City of Conway Mayor s Office 1201 Oak Street Conway, AR Invitation and Bid

Operating Manual. Models PAK-4 & PAK-4R Manual No. PAK002 (Rev 6 February 1999)

PANTHER. Self-Contained Breathing Apparatus (SCBA) Product Specification Sheet

Mobile Breathing Air Systems

GEORGIA DEPARTMENT OF CORRECTIONS Standard Operating Procedures IVN Authority: Effective Date: Page 1 of WETHERINGTON/HODGE 4/01/02

BCF WORK INSTRUCTION Respirator Inspection/Cleaning/Maintenance/Repair and Storage

This program shall contain, as a minimum, the following components:

MSA G1 SCBA. USA Edition

ACSi THE FUTURE OF SCBA

T E N D E R Tender # T SCOTT SCBA AIR PACKS AND ACCESSORIES SAINT JOHN FIRE DEPARTMENT

Dräger PSS 7000 with Dräger Bodyguard 7000

TROUSERS - Approved colors only (Dark navy, black, tan, khaki)

200 A, 15 and 25 kv class loadbreak bushing insert installation instructions

Transcription:

SPECIFICATIONS FOR THE PURCHASE OF FIFTY-EIGHT (58) SELF-CONTAINED BREATHING APPARATUS (SCBA)

SELF-CONTAINED BREATHING APPARATUS (SCBA) PROPOSAL FORM GREATER ROUND LAKE FIRE PROTECTION DISTRICT The undersigned vendor hereby proposes to furnish new, commercially produced Self-Contained Breathing Apparatus (SCBA) in accordance with the Greater Round Lake Fire Protection District s specifications and the vendor/manufacturer s detailed specifications incorporated herein. Any exceptions to the Greater Round Lake Fire Protection District s specifications are listed on the following exception page(s). It is agreed by the undersigned that the signing and delivery of this proposal represents the bidder s acceptance of the terms and conditions of the attached specifications and provisions and, if awarded this contract, will represent the agreement between the parties. SCBA Manufacturer: Authorized Agent (Vendor): Company Name Company Name Address Address City, State, Zip Code City, State, Zip Code Telephone Number Telephone Number Fifty-eight (58) SCBA sets as per these specifications, each consisting of one (1) SCBA unit, two (2) Cylinder and one (1) Facepiece. Eight (8) additional facepieces. Total Project Cost. Proposals are due Wednesday, November 2, 2016 at 3:00 pm local time. Delivery of the completed SCBA units and facepieces is to be made within calendar days from the acceptance of the bid by the Greater Round Lake Fire Protection District. Failure to deliver all equipment in the time quoted above, without the expressed permission of the purchaser will constitute a breach of contract and said agreement may be voided. Page 1 of 11

ACCESSORY PRICING FORM GREATER ROUND LAKE FIRE PROTECTION DISTRICT Please list your unit cost for each of the SCBA accessories listed below. For those accessories not available, indicate N/A in the pricing column. Additional Facepieces as per bid specification. CBRN APR filter adapter for facepiece price each. Interface for Motorola XTS5000 portable radio (if available). Hardware and/or software for scene accountability and tracking of individual SCBA. SCBA integrated thermal imaging system. Rapid Intervention System including True North or equivalent bag, regulators/hoses/fittings, RIC and 2 nd stage regulator connections and mask. Threaded CGA to SCBA quick-connect fitting adaptor for fill station. Rechargeable battery pack for SCBA. Charging system for rechargeable SCBA battery pack system will charge battery pack(s) simultaneously. Quick fill RIC hose for SCBA. System is to be waist-mounted in a secure pouch. Page 2 of 11

EXCEPTION PAGE List all exceptions by specification line number and describe the nature of the exception being taken. Use additional pages if necessary. Page 3 of 11

Section 1: General Greater Round Lake Fire Protection District Self-Contained Breathing Apparatus (SCBA) Request for Proposals The Greater Round Lake Fire Protection District (District), a municipal corporation, is seeking sealed proposals from qualified vendors and/or manufacturers to supply fifty-eight (58) new self-contained breathing apparatus (SCBA) and eight (8) additional facepieces. The final quantity and accessory items purchased may be different based on the awarded contract price for each item. This purchase is funded through a 2015 Department of Homeland Security Assistance to Firefighters Grant for 408,056. Specifications and all contract documents are provided herein. Bidders shall provide a detailed proposal with all required sections as specified. Any exceptions to the specifications presented herein must be clearly described on the exception page(s), otherwise, it will be considered that all SCBA offered will be in strict compliance with these specifications. SCBA that fail to meet the minimum specifications will not be considered and/or accepted. Any vendor failing to meet the obligations required upon acceptance of a proposal by the District may be required to pay damages to this District in conjunction with their failure. Section 2: Proposal Information Vendors must complete all information requested on the proposal form. Sealed proposals will be accepted until 3:00 p.m. local time on Wednesday, November 2, 2016. Proposals will be opened and read aloud at that time. All proposal packages shall be clearly marked SCBA PROPOSAL on the front. Sealed proposals must be sent or delivered to: Chief Greg Formica Greater Round Lake Fire Protection District 409 W. Nippersink Road Round Lake, IL 60073 Page 4 of 11

By signing the proposal form, the vendor acknowledges that said proposal is made without any understanding, agreement or connection with any other person, firm or corporation submitting a proposal for the same purpose and that said proposal is in all respects fair and without collusion or fraud. The Board of Trustees of the Greater Round Lake Fire Protection District reserves the right to accept or reject any or all proposals, waive any informality, and accept the proposal which it deems most favorable to the interests of the District. No proposals shall be withdrawn for a period of sixty (60) days after November 2, 2016 without the consent of the District. Questions concerning these specifications or proposal requirements should be directed to: Deputy Chief Joseph Krueger Greater Round Lake Fire Protection District 409 Nippersink Road Round Lake, IL 60073 Phone: (847) 546-6001 Documents required to be supplied with the vendor proposal include the following: Proposal Form completed and signed as required (page 1). Accessory Pricing Form (page 2). Exceptions Page(s) detailing any exceptions to the GRLFPD specifications. For each exception, the vendor must explain the details of the exception and offer, if available, an alternative feature. Copy of certification to NFPA 1981-2013 from the issuing agency. Detailed specifications for the SCBA being bid and any accessories where pricing was provided on the accessory pricing page. Detailed narrative describing anticipated delivery schedule, method of shipping and any services that will be provided by the vendor and/or manufacturer to assist with implementing the SCBA and any ancillary equipment into service. Detailed narrative describing the warranty provided by SCBA manufacturer and the maintenance capabilities of the manufacturer and vendor. Discussion should include information outlining: o Duration of warranty delineated by components as necessary. o Specific listing of any components not covered by warranty. o Any maintenance agreements (with cost) offered by the proposer. o Location, capacity and capabilities of SCBA repair facilities. o Response time and anticipated turnaround time for repairs. o Availability and hours of operation of online and/or telephone based technical support. o Availability & cost of loaner SCBA program or other services to reduce downtime. Page 5 of 11

Detailed narrative that describes the recommended training plan that the Fire District should implement in support of the new SCBA program. The plan shall address initial and ongoing training needs and include training to be provided to the Fire District by the proposer (including timing, duration & capacity of sessions, and any costs to the District. Detailed narrative that provides specific information on the anticipated cost of ownership of the proposed SCBA over the life of the unit. Discussion shall include: o Initial product cost. o All recommended preventive maintenance requirements including required intervals and anticipated cost. o All testing procedures required as per NFPA and regulatory compliance. Discussion shall include: Recommended or required testing intervals. Per unit test cost including parts & labor. Test location and any transportation costs associated with testing. o Anticipated repair maintenance costs for consumable items such as facepiece components, rechargeable battery packs etc. Discussion shall itemize the anticipated wear items, their expected service life and replacement cost. o Anticipated spare parts inventory required to have on site to support reliable SCBA uptime. Discussion shall include an itemized list of parts, recommended inventory and their cost. Certificate of Insurance or affidavit indicating a minimum of 3,000,000 product liability insurance. List of users in the Chicagoland area (for proposed make and model SCBA). Reference list (with name and contact information for Fire Chief) providing a minimum of five (5) full-time fire departments that have purchased the SCBA model proposed in the bid within the previous 12 months. Section 3: Delivery, Documentation & Training The order is to be shipped to the Greater Round Lake Fire Protection District, 409 W. Nippersink Road, Round Lake, IL 60073 with the vendor paying all shipping costs. The order is to be delivered in entirety as one package on the same date the Fire District will not accept partial shipments. The complete order shall be received within 60 days from date of order unless the vendor serves prior notice to the District and the District accepts the later delivery date. Delivery must be during the District s normal office hours of Monday Friday between 8:00 am - 4:00 pm Documentation to be supplied at the time of delivery includes a quality assurance test report for each individual SCBA delivered and four (4) copies of the following: User manual for each component. Care and maintenance instructions for each component. Warranty for each component. Page 6 of 11

The District reserves the right to inspect any and all materials, components, equipment, supplies, services or completed work specified herein. Any of said items not complying with these specifications are subject to rejection at the option of the District. Any items rejected shall be removed from the premises of the District and/or replaced at the expense of the vendor. The vendor shall provide training for all members of the District. The training shall instruct all Fire District personnel in the operation and maintenance of the SCBA. Training sessions shall occur for each of the three (3) shift battalions on days mutually agreeable to both the bidder and the Fire District. Section 4: Selection Process & Criteria The District will review all proposals received as part of a structured evaluation process. The purpose and intent of the process is to determine which proposal best meets the District s current and future needs including interoperability capabilities with surrounding fire departments. A review committee will evaluate all responses to the RFP that meet the submittal requirements and deadline. Submittals that do not meet the minimum requirements or deadline will not be considered. Proposals will be evaluated and ranked based on the following criteria described below: 4.01 Technology / Equipment Functionality: a. SCBA is manufacturer s newest and most technologically advanced product. b. Status of product life cycle of vendor s SCBA with respect to competition. c. Technical components of the SCBA as required by the District. d. Capability and functionality of each proposed operational feature. e. Capability to standardize the type of SCBA used by our neighboring fire departments for interoperability. 4.02 Delivery Plan: a. Feasibility and timeliness of delivery schedule. b. Degree of assistance to be provided to the Fire District by the vendor during implementation of the new SCBA. 4.03 Training: a. Level of on-site training provided at implementation of new SCBA. b. Vendor s availability/willingness to provide future training. c. Availability/quality of training materials provided by vendor. 4.04 Maintenance and Support: a. Vendor s capability / experience in providing maintenance service. Page 7 of 11

b. Vendor response time / proximity of service center / number of trained technicians. c. Turnaround time for repairs / quality and depth of spare parts inventory / availability of loaner equipment. d. Availability of technical support via telephone, online, etc. 4.05 Warranty: a. Meets the minimum warranty requirements as specified under the specifications section of this RFP (Section 5). 4.06 References: a. Demonstrated ability to successfully provide equipment of comparable complexity and quantities as described in this RFP to other municipal fire departments or fire protection districts. 4.07 Cost: a. Projected cost of ownership. Section 5: Specifications 5.01 Intent: The intent of this specification is to purchase new, unused NFPA 1981-2013 edition compliant SCBA and accessories including delivery of all said purchases and training on their operation and maintenance. Proposals shall only be considered from companies that have an established favorable reputation in the field of SCBA manufacturing. Each bidder shall furnish satisfactory evidence of its ability to construct the SCBA as quoted and render prompt service and/or replacement parts as needed. 5.02 Compliances: All SCBA and accessories shall be approved by the National Institute for Occupational Safety and Health (NIOSH) under 42 CFR Part 84 for chemical, biological, radiological and nuclear protection (CBRN) with a 30-minute rated service life and compliant with all requirements of the National Fire Protection Association (NFPA) 1981, Standard on Open-Circuit Self- Contained Breathing Apparatus (SCBA) for Emergency Services, 2013 edition and NFPA 1982, Standard on Personal Alert Safety Systems (PASS), 2013 edition. Only proposals for SCBA currently listed on the SEI website as approved to NFPA 1981-2013 will be accepted. 5.03 Detailed Specifications: The following specifications represent the District s minimum requirements for the purchase of SCBA. Products containing alternate specifications must meet or exceed these requirements. Vendors that are interested in proposing equal or better than alternatives shall include detailed information on the proposed product with their bid submittal. The overall safety of GRLFPD firefighters and the efficiency of operations will weigh heavily in Page 8 of 11

the final determination of the acceptability of alternate products during the review process and the District s decision shall be final. Component Required Features Overall: Standards / Compliance: SCBA shall meet requirements set forth in NFPA 1981, Standard on Open-Circuit Self-Contained Breathing Apparatus (SCBA) for Emergency Services 2013 edition. SCBA shall meet requirements set forth in NFPA 1982, Standard on Personal Alert Safety Systems (PASS) 2013 edition. SCBA shall be 42 CFR Part 84 certified by the National Institute for Occupational Safety and Health (NIOSH) to provide chemical, biological, radiological and nuclear (CBRN). SCBA shall pass intrinsic safety testing UL913 6 th edition. SCBA shall be of the open circuit compressed air pressure demand (positive pressure) type. Features / Technology: Proposed SCBA must be the latest model and technology offered by the manufacturer. SCBA to include Emergency Breathing Safety System (EBSS) compliant to NIOSH and NFPA 1982, 2013 edition. System is to be waist-mounted in a secure pouch. SCBA shall have a single rechargeable power source that operates all electronics including Heads Up Display, PASS, Control Module, Voice Amplification System and Indicator Lights and Radio Interface Option. No accessory or feature may use a power source separate from the central power supply. Control module shall be programmable by end user and have both an analog pressure gauge and color LCD digital display. Facepiece: Size / Fit: Maintenance / Care: A minimum of three (3) facepiece sizes must be available to fit all wearers. Multiple nose cup sizes must be available. Facepiece must include a protective bag for storage. Facepiece harness must be fabric with a 5-point strap that is replaceable without the use of special tools. Page 9 of 11

Configuration / Electronics: The facepiece lens shall be one piece and constructed of impact resistant polycarbonate material in a double curve design; it shall be optically correct and have permanent anti-fog and hard coating. No electronics, modules or batteries to be located in or mounted to facepiece. Connection of the second stage regulator must be either push in or quarter turn and require a single hand to be accomplished. Heads-Up Display: Features: To be located in/on second stage regulator. Visual indicators must be located so that they are viewable by the wearer and others viewing the wearer s facepiece. Features to be programmable by purchaser. Voice Amplifier: General Features: Voice amplifier to be integrated into SCBA and included with every unit as a standard feature. Breathing noise reduction/removal to be provided by technology. Cylinder: Pressure / Capacity: Construction / Configuration: All cylinders to be 4,500 psi. (113) cylinder bottles to be 30 minute capacity. (3) cylinder bottles to be 60 minute capacity. Cylinders shall have a quick connect fitting in place of the CGA threaded connection. Cylinders shall be lightweight carbon wrapped composite construction. Cylinder hand wheel shall be of the non-ratchet or locking type. Cylinders are to be labeled with a colored graphic Greater Round Lake Fire Protection District logo, be sequentially numbered from 1 113 for 30 minute bottles and 114 116 for 60 minute bottles and have (2) horizontal stripes (one upper and one lower). All are to be in bold fluorescent/reflective material. Numbers and stripes are to be 1 ½ high. All are to be visible from the rear of the firefighter with the cylinder secured into the SCBA. Page 10 of 11

Backplate/Harness/Carrier Assembly: Design/Construction: Composite or metal backplate frame is acceptable. Universal cylinder band shall be made of metal and adjustable in the field without tools so as to accommodate all cylinder sizes. Waist belt connection is to be of the seat belt type. Waist band is designed for firefighter comfort with features including swivel and height adjustment capabilities at the connection to the frame. Waist band height is adjustable. Shoulder pads shall have sleeves with reflective graphics for the routing of pneumatic hoses and electrical cables that are accessible through snap buttons. All straps shall be constructed such that they can be easily loosened/tightened with a gloved hand Harness shall have flashing indicator lights that indicate status of heads up display and PASS alarm. Indicator lights shall be visible from top/front, bottom/rear and both sides. Warranty / Service: Duration/Coverage: Service: Warranty shall cover entire SCBA with the exception of consumables and rechargeable batteries for a period of 15 years. Mobile service to be available through the vendor. Repair facility to be located in the Chicagoland area. Page 11 of 11