KTM 50 (DN ) Installation, maintenance and operating instructions

Similar documents
Steam Trap BK 15 (DN40, DN 50) Original Installation Instructions English

Pressure Reducing Valve for Steam Type 2333 A

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Engineering Data Sheet

TA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics

CRP INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SAMPLING VALVES

Bermad Pressure Reducing. Model: 42T

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Steam Trap BK BK 212-ASME. Original Installation Instructions English

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

TA-FUSION-P. NPT threads / ANSI flanges

SCA Series Inverted Bucket Steam Traps

STAG. Balancing valves Balancing valve with grooved ends DN

SLAM-SHUT VALVE. Type OSE CONTENTS INTRODUCTION CHARACTERISTICS. Scope of Manual. Material. Product Description. Connections

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

WW-730. Pressure Sustaining/Relief Control Valve

Installation & Operation Manual Proven Quality since 1892

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

BSA6T and BSA64T Stainless Steel Bellows Sealed Stop Valves Installation and Maintenance Instructions

INSTALLATION, OPERATION

Serie 06-M6. Swing wafer check valve. made in. Application fields. Check valves E U R O P E WATER CONDITIONING INDUSTRY

Materials : Stainless steel ASTM A351 CF8M

Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections

Model: 43T. Bermad Pressure Relief Valve

WW-720. Pressure Reducing Control Valve

Pressure Independent Control Series

VALVES & MEASUREMENT

ROTATING DISK VALVES INSTALLATION AND MAINTENANCE 1. SCOPE 3 2. INFORMATION ON USAGE 3 3. VALVE TYPES 3 4. OPERATORS 5 5. VALVE CONSTRUCTION 6

Model GPR Primary Pressure Regulating Valve. Instruction Manual

WW-720. Pressure Reducing Control Valve

CLASS TLP Pressure Reducing Valve

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

Operation and Maintenance Instructions. VAG PICO Pilot Operated Control Valve

Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL PRV44

INSTRUCTIONS AND MAINTENANCE MANUAL SERIES: RT

INSTALLATION, OPERATION & MAINTENANCE MANUAL

STAP. Differential pressure controllers DN , ANSI flanges

1. Preface Important Safety Notes Brief Product Information Product Working Principle Installation Guidelines...

Cast iron swing check valve. BS EN 12334:2001 PN16

Installation, operation & maintenance manual - original version

GM Series Dual-Block Multi-Function Gas Control Valves

Materials : Carbon steel ASTM A216 WCB

Differential Pressure Control Valve (DPCV)

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

DUPLEX TECHNICAL INFORMATION FABRICATED DUPLEX STRAINERS

C 10 Pressure Reducing Valve

TECHNICAL DATA. Page 1 of 12

GREIG FILTERS, INC. OPERATION MANUAL

Model GP-1000 Series PRESSURE REDUCING VALVE. Installation & Operation Manual

Declaration of Conformity as per Directive 97/23/EC

OPERATING INSTRUCTIONS

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections

SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation. Size: inch / mm

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

Combination Air Valve

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

INSTRUCTIONS AND MAINTENANCE MANUAL SERIES: K

Pilot Operated Pressure Reducing Valve

End Connection. Thread x Thread N/A N/A N/A N/A Flange x Flange N/A

Declaration of Conformity as per Directive 97/23/EC

TECHNICAL DATA CAUTION

AVK SERIES 601, 602, 603 & 605 UNIVERSAL COUPLINGS, ADAPTORS & END CAPS INSTALLATION, OPERATION & MAINTENANCE MANUAL

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Installation, Operation and Maintenance Instructions Buffer Vessel OM006

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

CA10S, CA14 and CA14S Air and Gas Traps

Caution: Safety Precautions: Installation, Operation & Maintenance Manual. For Modentic Needle Valves with Threaded Ends

MZX. Three-Port Seat Valves SPECIFICIATIONS AND GUIDE TO SELECTION

GESTRA Steam Systems AK 45. Installation Instructions Condensate Drain Valve AK 45

TBV OPERATION AND MAINTENANCE MANUAL SERIES 2800: FLANGED BALL VALVE. For technical questions, please contact the following:

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL M2

PRESSURE REDUCING VALVE RP45 (EN)

Types S100K and S102K Pressure Regulators

INSTALLATION AND MAINTENANCE INSTRUCTIONS IB - INVERTED BUCKET STEAM TRAPS (IB12 - IBB - IB30 IB35)

STAP. Differential pressure controllers DN , ANSI fl anges

k valve 2 (50)HF 2½ (65)SF installation guide aylesbury For valve sizes (DN): tel fax

STAINLESS STEEL LOW PRESSURE REDUCING VALVE LPRV ELITE

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Type Type Differential Pressure Regulators (opening)

CARTRIDGE FILTERS TECHNICAL MANUAL MT 080. Installation, commissioning and maintenance instructions. 08/02 Edition

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

2-port and 3-port valves PN 16

Apollo Standard Port, Full Port & One Piece Flanged Ball Valves Installation, Operation, & Maintenance Manual

2-port seat valves PN25 with externally threaded connections

GESTRA Steam Systems BK 45 BK 45U BK 46. English. Installation Instructions Steam Traps BK 45, BK 45U, BK 46

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

HERZ-Motorised flow controler

Installation, commissioning and servicing instructions

TECHNICAL DATA. Q = C v P S

CRP Ltd INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SYRINGE SAMPLING SYSTEMS

Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

Control Valve with ZK Radial Stage Nozzle ZK 210. Original Installation Instructions English

Transcription:

52 762-306 09.2014 KTM 50 (DN 100-200) Installation, maintenance and operating instructions

General High-performing and compact, these pressure-independent control valves for variable flow heating and cooling systems are particularly effective in situations requiring high temperatures and/or pressure drops. They are also suitable for use on the primary and secondary side in district heating and cooling systems. Ductile iron body - painted with duasolid offering good rust protection. Marking The valve displays the following data: TA - Manufacturer: according to table 3 Material: according to table 2 DN: according to table 2 Max. (PN) working pressure according to table 2 CE-marking according to table 1; 3 Unidirectional flow arrow for the recommended direction of flow Max. permitted temperature: 120 C (table3) Date of manufacture: year, week (table 3) Installation - Preparation Installation Ensure valve is suitable for service conditions e.g. pressure, temperature, service media. The valve serving the terminal unit can be installed in the flow or the return pipe - Heating Ensure the pipe system has been cleaned. Ensure the strainer is installed. Ensure all sealing surfaces are clean and undamaged. The installation shall provide adequate means of draining and venting to avoid harmful effects such as water hammer, vacuum collapse, corrosion and uncontrolled chemical reactions and to permit cleaning, inspection and maintenance in the correct manner. - Cooling The valve has been designed for load, appropriate to its intended use and other reasonably foreseeable operating conditions. Load caused by traffic, wind and earthquake, have not been taken into account. 2

Valve may be installed in vertical, horizontal or inclined pipeline. The valve should be installed to match the direction of flow, with the flow direction arrow shown on the valve body or on the identification plate. Install the valve so that venting is possible and the flow adjustment scale is visible and accessible Check allowed positions of the actuator and provide adequate space for future service and maintenance. Installation of a strainer upstream of the valve is strongly recommended Flange joints Flanges may be damaged by over tightening the bolts. The following procedures will reduce this risk: Check that the counterflanges are parallel before the valve is installed Lubricate the threads on the bolts and fit washers. Ensure adequate lubrication of bolts and washers. Full faced gaskets should be used with integral flanges according to standard. EN 1092-2:1997 (Type21). Note: To ensure flow measurement accuracy it is essential that the piping on the inlet and outlet sides is straight and has a minimum uninterrupted length equivalent to 5 diameters at inlet and 2 diameters at outlet as shown: Always use the correct size and number of bolts. Tighten the bolts crosswise using a torque wrench to the tightening torque set out in table 4. If the valve is located on the outlet from a pump than it is essential that the straight uninterrupted pipe length between pump outlet and valve inlet is a minimum of 10 diameters. Check that the full faced gaskets are in accordance with them given standard for flanges and that they are centered correctly on the sealing surfaces. 3

Start-up procedure Install the valve into dry pipe. Verify the installation of a strainer upstream of the KTM valve. Isolation valves at the inlet and outlet side of the KTM should be closed. Fill the system with the tap water from the reverse side by slowly opening the isolation valve at the outlet side of the KTM, while the isolation valve at the inlet side of the KTM is still closed. Actuator should be switched off and control valve should be full open. When isolation valve on the outlet side of the KTM valve is fully open and the valve is under pressure, vent the valve by using 14 mm spanner. 4

Switch on the actuator and slowly open the isolation valve at the inlet side of the KTM. Reversing the flow and flushing through the KTM valve is not allowed!!! Pre-commission Check that the arrow on the valve body is in the same direction as the flow. Fully open the valve by unscrewing the throttle anti-clockwise with spanner according to table 5, from 50% to 100% open (factory setting is 50%) Ensure that actuator is switched off. Check that the strainer basket is clean. Slowly fill the system with the tap water according to the Start-up procedure Close the bypasses. Commission Uninstall the actuator. Set the flow. Install the actuator. Be sure that the actuator is switched off. Slowly raise the pressure to working pressure. Vent the valve. Check sealing. Check sealing. Maintenance The valves are maintenance free under the condition that they are used within their normal application. 5

Presetting The valve s opening position can be read on the digital label on the throttle. Factory setting is on half open (50%). Example of presetting the valve to 5.5 turns is done as follow: Unscrew the fix nut on the throttle. Use the spanner according to the table 5. Flow chart is valid when p cross the valve is 1 bar. If Δp cross the valve is less than 1 bar, or much greater than 1 bar means, that flow chart is useful for approximately presetting. Fully close the valve by screwing the throttle with the spanner according to the table 5. Fix the throttle with fix nut. Set the flow according to the flow chart supplied with the valve. Unscrew the throttle for 5,5 turns. Count the turns. 6

Trouble-shooting guide 1. Valve is fully open and design flow is not able to be measured Check pump head is sufficient and in manual mode Ensure all by-pass valves are closed Check all control valves are fully open Check strainers are not blocked Ensure that water is not being drained at another part of the system. If possible measure the pressure drop of the control valve fully open and check Kv. 2. Valve is adjusted but no change in flow is measured Check valve chamber is vented and water is evident, if not; - Capillary may be blocked with dirt. (a fine hard wire may dislodge trapped dirt) - Throttle in valve body may be blocked with dirt. (a fine hard wire Ø 1 mm may dislodge trapped dirt) Tables Table 1 Categorization according to directive 97/23/EC (PED) PS (PN) PN 16 PN 25 Article 3&3 DN 15-40 Category I DN 65-200 DN 50-125 Category II DN 150-200 Table 2 Markings on housing / plates DN 100 125 150 200 Material ü ü ü ü DN ü ü ü ü PN ü ü ü ü Table 3 Marking on plates DN 100 125 150 200 Logo - TAH ü ü ü ü CE ü ü ü ü Temp. C ü ü ü ü Flow ü ü ü ü Date ü ü ü ü Table 4 Bolts, gaskets, torque DN 100 125 150 200 Threads M16/M20 M16/M24 M20/M24 M20/M24 Screw length 75 75/85 80/90 90/95 N 8 8 8 12 Nm 200 280 310 550 Gasket 168/115x2 194/141x2 218/169x2 184/220x2 Table 5 Turns of throttle DN 100 125 150 200 16/30 16/30 16/30 16/30 Turns 10 10 10 10 7

Start-up procedure - fill form 1. Pre-commission Check 1. Install the valve in the pipeline according by the arrow on the label (flow direction) 2. Unscrew the throttle from 50% on 100% open (factory setting is 50%) 3. Be sure that actuator is not on the valve 4. Check that the strainer basket is clean 5. Slowly fill the system with the tap water 6. Close the bypass 7. Check sealings 2. Commission Check 1. Be sure that actuator is removed and the valve (throtle) is fully opened 2. Slowly rise the pressure to workin pressure 3. Vent the valve 4. Check the sealing 5. Check the flow according to the flow chart 6. Check the flow on orifices or on measuring points, if exist 7. Install the actuator on the valve Location/object: Valve typ: Date: Signature: -----"------------------------------------------------------------------------- Notes: We reserve the right to introduce technical alterations without previous notice. www.imi-hydronic.com