Radiator valves VDN1.. VEN1..

Similar documents
Radiator valves VDN2.. VEN2.. VUN2..

3-port seat valves with externally threaded connection, PN 16

2-port and 3-port valves PN 16

2-port seat valves PN25 with externally threaded connections

2-port and 3-port seat valves, PN16

Two-port valves, male threaded, PN25

2-Port Seat Valves with Flange, PN 16

Dynamic Valve Type RA-DV Pressure Independent Radiator Valve

2-Port and 3-Port Seat Valves with Female Thread, PN16

2-Port Seat Valves with Flange, PN 16

AVP-F. p setting range (bar) Code No. 003H6200

RA-N radiator valves with integrated presetting and self-sealing tailpiece

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting

Pressure Independent Control Series

Seated valves VRB 3, VRG 3

HERZ-Motorised flow controler

Products no longer available

Rp [ ] Sv min. [ ] C215QP-B 15 1/ C215QP-D 15 1/ C220QP-F 20 3/ [ ]

Differential pressure controller (PN 16) AVPL return mounting, adjustable setting

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

Three-port valves. Special versions with special stem sealing gland for: High temperature hot water C Thermo oils

Rotary valves HRB 3, HRB 4

Type overview. R B2 en-gb subject to changes 1

BTV. Internally threaded 2-way control valve. Flow characteristics. Function

Two-port seat valves

Products no longer available

Ballorex Dynamic Description. Versions. Benefits. Balancing

AVPQ/AVPQ-F, PN 16. Application

Overview of types. Technical data. Safety notes

Pressure balanced valves (PN 25) VM 2 2-way valve, external thread VB 2 2-way valve, flange

VZL valve - 2/3/4-way

Chrome plated radiator valves type RA-NCX and lockshield valves type RLV-CX

Presetting Valve Type RA-N with Flange Connection

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Differential pressure controller (PN 16) AVPL - return mounting, adjustable setting

Pressure balanced valves (PN 25)

Differential pressure control and flow limiter AVPB/AVPB-F, PN 16

Rotary valves HRB 3, HRB 4

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange

Overview of types. Technical data

HERZ - Compact Flow Controller with

Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN

TBV-CM. Combined control & balancing valves for small terminal units For modulating control

Modulating refrigerant valves with magnetic actuator, PS45 Hermetically sealed, for safety refrigerants

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

V5001P. Kombi-Auto Differential Pressure Control Valve. Product specification sheet

VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH...

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS

STAP. Differential pressure controller DN 15-50

3-way control valves VK 3

Technote. Frese PV-SIGMA Compact Dynamic Pressure and Flow Regulation. Description. Application. Operation. Features. Benefits.

VBGx-xx-xx Externally Threaded Control Ball Valves PN25 (DN15 TO DN32)

Pressure Reducing Valve DMV 755

Multifunctional Thermostatic Circulation Valve MTCV - Lead free brass

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Double valves for biogases and recycling gases

Differential pressure controller with flow limitation (PN 16, 25, 40) AFPB / VFQ 2(1) AFPB-F / VFQ 2(1)

TA-Modulator. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve for modulating control

Pressure reduction controller (PN 16, 25, 40)

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

STAP. Differential pressure controller DN

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

Seated valve for steam (PN 25)

DIFFERENTIAL PRESSURE REGULATING VALVE zcon

TA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics

Propor tional Re lief Valve s

VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH...

Solenoid valves VZWF, force pilot operated

Pressure independent control valve (PICV) FLOWMATIC

Gas Pressure Regulator HON 300

Automatic balancing valves ASV

VBGx-xx-xx Externally Threaded Control Ball Valves PN25 (DN15 TO DN32)

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve

Valves for Biogases and Recycling Gases

C 10 Pressure Reducing Valve

Automatic balancing valves ASV

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

Serie 06-M6. Swing wafer check valve. made in. Application fields. Check valves E U R O P E WATER CONDITIONING INDUSTRY

VGF... VGH... Building Technologies Division Infrastructure & Cities Sector VGG... VGF... VGH...

VGG... VGF... VGH... Gas Valves. Siemens Building Technologies HVAC Products VGG... VGF... VGH...

MZX. Three-Port Seat Valves SPECIFICIATIONS AND GUIDE TO SELECTION

safety Shut-Off Valve HON 721

HERZ - Compact Flow Controller with

kyone for All - Unique Mixproof

Seated valve for steam (PN 25) VFS 2 2-way valve, flange

2 - way valve (NO) for steam, pressure relieved (PN 25) VGS - external thread

4/2 way Pneumatic Solenoid Valve

VGD40.../VGD41... Double gas valves. Building Technologies Division Infrastructure & Cities Sector

CLASS TLP Pressure Reducing Valve

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions

Pressure Relief Valve DHV 718

3 & 4-Way Mixing & Diverting Valves

VB-7211 Series. Application. Features. Applicable Literature. 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions

Gas Pressure Regulator HON 200

Upgradable balancing valves USV

Transcription:

2 105 EN 215 Straight valves VDN1.. Angle valves VEN1.. ACVATIX TM Radiator valves VDN1.. VEN1.. DIN-norm, for 2-pipe heating systems Valve bodies made of brass, mat nickel-plated DN 10, DN 15 and DN 20 Integrated presetting of the k v -values Internally and externally threaded (Rp/R) conforming to ISO 7-1 Manual knob / protective cover included in the delivery Can be combined with RTN.. thermostatic actuators, SSA.. electromotoric actuators, STA..3.. electrothermal actuators or SSA955 RF-controlled actuators CE1N2105en 2017-07-20 Building Technologies

Use The radiator valves are used in hot water heating plants for individual room or zone temperature control and limitation. They are basically recommended in all rooms, especially where heat gains or different temperature levels occur. Type summary Product number Product number DN X P k v-value [m 3 /h] 1 - N k vs-value [m 3 /h] without actuator straight angle N X P = 2 0.072 0.43 VDN110 VEN110 10 X P = 1.5 0.057 0.33 0.63 X P = 1 0.037 0.22 X P = 2 0.073 0.50 VDN115 VEN115 15 X P = 1.5 0.058 0.40 0.89 X P = 1 0.038 0.27 X P = 2 0.22 0.70 VDN120 VEN120 20 X P = 1.5 0.17 0.55 1.41 X P = 1 0.11 0.36 Ordering Example: Product number Order number Description Quantity VDN120 VDN120 straight valves 2 ATN2 ATN2 protection against dismantling 1 Delivery Valves and accessories are packed separately. Equipment combinations Actuators Product numbers Data sheet Thermostatic actuators RTN.. N2111 Electromotoric actuators SSA31.. / SSA61.. / SSA81.. N4893 RF-controlled electromotoric actuators SSA955 N2700 Electrothermal actuators STA..3.. N4884 2/14

Function / mechanical design The flow rate can be preadjusted with an orifice. Full stroke is ensured irrespective of the preadjustment, which is made with the help of the protective cover. 1 Manual knob / protective cover 2 Sealing gland 3 Valve insert 4 O-ring 5 Reset spring 6 Orifice Features and benefits The valves conform to EN 215 The sealing gland can be replaced while the plant is under pressure (no tools required) Accessories ATN2 Protection against dismantling ATN4 Manual knob AVN.. Compression fittings 3/14

Engineering notes The reference numbers for preadjustment are given in the table with the k v -values (see page 5) and in the valve sizing charts (see pages 7 6). 1. Calculate the volumetric water flow V % 100. Q 1.163 ΧT f 100 V 100 < [m 3 /h] 1 Q 100 = heat demand [kw] ΔT = temperature differential [K] 1.163 = constant of water f 1 = correction factor = 1 for water 2. Define the pressure drop Δp v100 across the fully open valve In most types of plant, a differential pressure Δp v100 of 0.05 to 0.2 bar is adequate. 3. Calculation of the nominal flow value k v k v V% 100 < [m 3 /h] Δp v100 = differential pressure across the valve [bar] Δp v100 Example: Heat demand Q 100 = 1.2 kw Temperature differential ΔT = 20 K Water volume. V 100 1.2 < 1.163 20 = 0.052 m 3 /h = 52 l/h Required differential pressure across the valve Δp v100 = 0.1 bar Flow 0.052 k v < = 0.17 m 3 /h 0.1 Solution According to the chart (refer to "Valve sizing charts", page 7 or table with k v -values), the preadjustment required by a VDN110 3/8 valve is 2. Tips Noiseless operation is ensured by a pump that provides no more pressure than is needed to transport the required amount of water. To keep the valve free from dirt particles, it is recommended to install a strainer. 4/14

k v -values The k v value gives the volumetric water flow 100 across the valve of 1 bar. V. in m 3 /h at a pressure drop Δp v100 k v -values [m 3 /h] at the different preadjusted positions Control range with actuators SSA.. and STA..3.. Control range of thermostatic actuators RTN.. Reference numbers for preadjustment VDN110 / VEN110 XP 2K 1 2 3 4 5 N N(k vs ) 0.072 0.17 0.24 0.28 0.37 0.43 VDN110 / VEN110 XP 1.5K VDN110 / VEN110 XP 1K VDN115 / VEN115 XP 2K VDN115 / VEN115 XP 1.5K VDN115 / VEN115 XP 1K VDN120 / VEN120 XP 2K VDN120 / VEN120 XP 1.5K VDN120 / VEN120 XP 1K 0.057 0.135 0.19 0.23 0.29 0.33 0.037 0.089 0.13 0.145 0.19 0.22 0.07 0.17 0.28 0.36 0.45 0.50 0.058 0.14 0.23 0.28 0.35 0.4 0.038 0.9 0.15 0.18 0.24 0.27 0.22 0.35 0.44 0.52 0.60 0.71 0.17 0.27 0.35 0.42 0.46 0.55 0.11 0.18 0.23 0.28 0.31 0.36 0.63 0.89 1.41 5/14

Setting the k v -values The k v -values can be set on the valve s head in 5 steps + N (fully open) using the protective cover, which can be turned through 180. Observe marking on the valve s outlet side! 6/14

Valve sizing charts VDN110 VEN110 Xp Band 2 K 7/14

VDN110 VEN110 Xp Band 1.5 K VDN110 VEN110 Xp Band 1 K 8/14

VDN115 VEN115 Xp Band 2 K VDN115 VEN115 Xp Band 1.5 K 9/14

VDN115 VEN115 Xp Band 1 K VDN120 VEN120 Xp Band 2 K 10/14

VDN120 VEN120 Xp Band 1.5 K VDN120 VEN120 Xp Band 1 K 11/14

Notes Mounting Orientation Mounting Instructions are printed on the package. Mounting orientation depends on selected actuator. The valves are supplied preadjusted to N (fully open) To ensure correct functioning of the thermostatic heads and electronic actuators, observe the available mounting choices and mounting conditions 90 SSA.. SSA955 RTN51.. RTN71.., RTN81.., STA..3.. 90 2105Z01 90 90 4362Z01 90 90 90 90 2185Z12 Maintenance Repair Disposal The valves are maintenance-free. In the event of leakage, the valve s sealing gland can be replaced. The valves cannot be repaired; the complete unit must be replaced. Do not dispose of the device as household waste. Special handling of individual components may be mandated by law or make ecological sense. Observe all local and currently applicable laws and regulations. Warranty Application-related technical data are only warranted when used in connection with the Siemens controllers and actuators listed under "Equipment combinations", page 2. When using the valves with actuators of other manufacture proper functioning must be ensured by the user. Any warranty by Siemens becomes void. 12/14

Technical data Functional data PN class PN 10 Suitable media 1) cold and low-temperature hot water, water with propylene-glycol, water with ethylene-glycol < 30%; recommendation: water treatment to VDI 2035 Medium temperature 1 120 C Perm. operating pressure 1000 kpa (10 bar) Differential pressure Χp max max. 60 kpa (0.6 bar) Differential pressure Χp v100 5 20 kpa (0.05 0.2 bar): recommended range Stroke min 1.2 mm Materials Valve body brass, mat nickel-plated Fitting brass, mat nickel-plated Protective cover polypropylene O-ring EPDM, NBR Dimensions / weight refer to "Dimensions", page 14 Mounting length EN 215 Standards, directives and approvals Thread Pressure Equipment Directive Rp internally threaded R externally threaded G-thread PED 2014/68/EU Pressure Accessories Scope: Article 1, section 1 Definitions: Article 2, section 5 to ISO 7-1 to ISO 7-1 to ISO 228-1 Fluid group 2: DN 40 without CE-marking as per article 4, section 3 EAC Conformity (sound engineering practice) 2) Eurasia Conformity Environmental compatibility The product environmental declaration CE1E2105en 3) contains data on environmentally compatible product design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal). EU conformity (CE) CE1T2100 3) 1) Prefer propylene-glycol for environment protection reasons. 2) Valves where PS x DN < 1000, do not require special testing and cannot carry the CE label. 3) The documents can be downloaded from http://siemens.com/bt/download. 13/14

Dimensions VDN1.. E 2105M01 VEN1.. E R Rp R D D C C G l 2 l 1 B G Rp l 4 l 3 2105M02 Dimensions [mm] Thread [inch] Weight Prod. no. DN l 1 l 2 l 3 l 4 B C D E Rp R G [kg] VDN110 10 59 85 53 18 35 ⅜ ⅜B ⅝ 0.240 VDN115 15 66 95 53 18 35 ½ ½B ¾ 0.285 VDN120 20 74 107 53 18 35 ¾ ¾B 1 0.410 VEN110 10 26 52 22 53 18 35 ⅜ ⅜B ⅝ 0.225 VEN115 15 29 58 26 53 18 35 ½ ½B ¾ 0.270 VEN120 20 34 66 29 53 18 35 ¾ ¾B 1 0.375 Prod. no. DN Compression fittings for copper and soft steel pipes for plastic pipes with aluminum foil VDN110 10 Prod. no. Connection valve side Connection pipe side Prod. no. Connection valve side Connection pipe side [Inch] pipe Ø [mm] [Inch] pipe Ø [mm] VDN115 15 AVN15-15 ½ 15 AVN15-A16 ½ 16 x 2 VDN120 20 VEN110 10 VEN115 15 AVN15-15 ½ 15 AVN15-A16 ½ 16 x 2 VEN120 20 Published by: Siemens Switzerland Ltd. Building Technologies Division International Headquarters Gubelstrasse 22 6301 Zug Switzerland Tel. +41 41-724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd 2006 Delivery and technical specifications subject to change 14/14