Psyclone TM. Protimeter Thermo-Hygrometer. GE Sensing. Operating Manual. INS7800, Rev. A (September 2007)

Similar documents
GE Measurement & Control

Owner s Manual Humiport 10/20

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

SPECIFICATIONS APCEPH1

Advanced Test Equipment Rentals ATEC (2832)

RAM 4021 Operation Manual

In Vivo Scientific, LLC INSTRUCTION MANUAL

LM6 LEATHER MOISTURE METER

PM105 PRESSURE METER USER S MANUAL

RAM 4021-DPX Operation Manual

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

OPERATING INSTRUCTIONS V 5.3

Handi+N2 OPERATING MANUAL & INSTRUCTIONS FOR USE. R218M06 Industrial. R218M06 Rev. E

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

Getting to know your Sureshotgps micro V3

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Handi+ OPERATING MANUAL & INSTRUCTIONS FOR USE. R218P15 Industrial. R218M15 Rev. D

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

Digital Vacuum Regulator

SMART Oxygen Analyzer. User Manual

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

Portable Gas Monitor GX User Maintenance Manual (H4-0050)

Ambient Weather WS-03 Thermo-Hygrometer

Atlas 6TM. Indoor Air Quality Monitor Instruction Manual. Measures CO 2, Temperature and Humidity DISTRIBUTED BY

User s Guide Temperature Sensor Converter TSC-599

RAM Operation Manual

92831 TEL: (714) FAX:

HiVolCal User Manual High Volume Field Calibrator Model HVC1 (7 to 54 CFM) NIST Traceable ISO 9001:2008

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

Operating Manual. Check and Go Disposable Medical Depot, Inc Port Washington N.Y

RoVent Jr. Automatic Ventilator Volume & Pressure Controlled. User s Guide

QUICK START GUIDE Kestrel 5500 Weather Meter

GasLab SAN-102 Micro Oxygen Monitor User Manual

Fingertip Pulse Oximeter

For Models: 55A00-2 (HAI UPB 1500W Wall Switch Dimmer) 55A00-3 (HAI UPB 2400W Wall Switch Dimmer) 37A00-1 (HAI Auxiliary Switch)

Lifeloc FC10. Operations Manual. Unlock the Power of Alcohol Testing

GasLab SAN-102 Micro Oxygen Monitor User Manual

Table of Content 1 Introduction... 1

Heavy Duty Dissolved Oxygen Meter

Instruction Manual. Model DSP-Ex Portable Dewpoint Meter. Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272)

M104 Series: Digital Manometer: 0.1 % of Full Scale

Ambient Weather GL150-TH Nautical Thermometer Hygrometer (ComfortMeter) User Manual

Arena by Oregon Scientific

6 digital caliper with case

BI-680 Online Dissolved Oxygen Controller Instruction Manual

High Performance Electronic Components 1411 S. Roselle Rd Schaumburg, IL Fax

SPS-5. Rate Computing Scale. Operation Manual

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

HI 2314 HI 2315 HI 23151

INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE. SPORTS ATTACK LLC

NKhome.com

Dual-gas Oxygen and Carbon Monoxide SMART Analyzer User Manual

Golf Performance Monitors. PureContact Operating Guide. Version of 9

AED Trainer NF1200-T. Operator s Manual

Model AUTOMATIC UPPER ARM Blood Pressure Monitor

USER GUIDE 1000, 2000, 2500 & 2500NV, 3000, 3500 & 3500NV, 3500DT.

INSTALLATION MANUAL Residential and Small Commercial Applications

The Univentor 1250 Anaesthesia Unit

ENVIRONMENTAL INSTRUMENTS, LLC

EM151/EM201. Electronic Manometer - + INSTRUCTION MANUAL EM Washington Street Melrose, MA Phone Toll Free

Model 4140/4143 General Purpose Thermal Mass Flowmeter

Ocean Technology Systems ComBox

ATEX ATEX

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

Relative Humidity Calibration Kit

USER'S GUIDE. Vaisala Structural Humidity Measurement Kit SHM40 M211423EN-C

Controller for boilers Galan - regulator for management of heating elements and circuit SolarSentinel-DBTW User guide

PPS PORTABLE POWER SUPPLY

Model SM/PL Series. Calibration Guide. Precision Loads. Anritsu Company 490 Jarvis Drive Morgan Hill, CA USA

INSTALLATION MANUAL. Residential and Small Commercial Applications. Sensors just make sense

Robic M-477 Instructions and Operating Guide

DTG - LCD Digital Temperature Gauge USER MANUAL

Rev. 1. Cryogenics Thermoflasks. 2122, 2123, 2124, 2129, and 2130

EM151/EM201. Electronic Manometer - + INSTRUCTION MANUAL. EM201 PSI

Operation Manual. Pro He Alarm TM. Helium Analyzer. Rev 08.17

COMBAT SWIM BOARD. RJE International, Inc. TAC-300 Revision C. RJE International August 3, TAC-300 Revision C

700 SERIES BMS II BUBBLER MONITORING SYSTEM

4000 Series Pocket Weather Trackers Instruction Manual

-VERITAS- High Volume Field Audit Calibrator Dual Range Model HVC2 1.4 to 7 and 7 to 54 CFM. NIST Traceable ISO 9001:2008

Temperature Controller CC24-7 ULTRA USER S MANUAL Legion Dr. Mason, MI USA October 2010 Ph. (517) Fax (517)

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

! Warning, refer to accompanying documents.

WARRANTY, QUICK START GUIDE

OWNER S MANUAL. AXD 530 MicroManometer

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

Alcotest Breath Alcohol Screening Device. Operator Instructions for Use. ST _sw.eps

COMBAT SWIM BOARD. RJE International, Inc. RJE International January 16, TAC-300 Revision 4

American Weigh Scales, Inc. BLADE Series D i g i t a l P o c k e t S c a l e BLADE-550. User Manual BLADE-400 BLADE-1000

Field 1. Barometer Alarm Symbol. Field 2. Barometer Trend Indicator. Altimeter/Barometer Alarm Symbol Field 4. Altimeter Function Indicator

Model 4040/4043/4045 General Purpose Thermal Mass Flowmeter

RGC-IR Remote Gas Calibrator for IR400

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Operating Instructions Part No

Operator s Manual. The Bullet Blender Gold BB24-AU, BB5E-AU

Model Series 63DL Differential Type Flow Controller

SMART Carbon Monoxide Analyzer. User Manual

Transcription:

GE Sensing Psyclone TM Protimeter Thermo-Hygrometer Operating Manual INS7800, Rev. A (September 2007) Psyclone is a Protimeter product. Protimeter has joined other GE high-technology sensing businesses under a new name GE Sensing. Psyclone is a registered trademark of GE Sensing.

Introduction The GE Protimeter Psyclone thermohygrometer measures relative humidity with psychometric measurements, along with temperature. One button enables start, hold and OFF operation, and four arrow keys allow you to set up and change the measurements shown on the LCD screen. An optional surface temperature probe enables users to determine if condensation is present. Figure 1 below shows the Psyclone control buttons, while Table 1 on the next page lists the available parameters. On/Hold/Off Hold for 2 sec to enter Setup Figure 1: The Psyclone (#BLD7800) Control Buttons Protimeter Psyclone Page 1

Table 1: Psyclone Measurement Parameters Parameter % Relative Humidity % RH 1 Grains per pound GPP Symbol 2 Grams per kilo Gram Dewpoint Temperature Wet Bulb Temperature 2 Kilo Calorie per Kilogram 1 British Thermal Units per Pound Ambient Temperature Surface Temperature Proximity to Dew Point at the Surface g/kg DEW POINT WET BULB kcal/kg BTU/lb AMBIENT SURFACE TEMP DIFF 1 Displayed if F units chosen in Setup 2 Displayed if C units chosen in Setup Page 2 Protimeter Psyclone

Starting the Psyclone for the First Time The Psyclone comes with two AA, 1.5 V batteries already installed. To begin using the meter, extend the retractable probe and press the (ON) button. The LCD screen briefly flashes, similar to Figure 2 below. After a few seconds, the meter changes to measurement mode and displays only the currently selected parameters, as shown in Figure 3 on the next page. Moisture readings appear at the top, with temperature measurements below. Figure 2: Full Screen Display Protimeter Psyclone Page 3

Starting the Psyclone for the First Time (cont.) Figure 3: Typical Screen Display During Operation To freeze the Psyclone at a particular reading, press the button briefly. The Hold message appears to the left of the temperature reading, as shown in Figure 2 on the previous page. To shut off the Psyclone, press the button for 3 seconds, until the message OFF appears before the LCD blanks. Page 4 Protimeter Psyclone

Selecting Parameters and Calculations Use the four arrow keys to select the parameters and calculations you want to display. Press any of the arrow keys to scroll to the parameter row (shown in Figure 2); then press the RIGHT arrow key to scroll to the parameter or calculation. The reading changes immediately, and the parameter is set once the flashing stops. Pressing the parameter. instantly selects To select the humidity parameter (%RH, GPP or g/kg, or Dew Point): Scroll to the top row, and then to the desired parameter. Note: If you have selected the Psychometric Calculation On option, your options include the available calculations. Protimeter Psyclone Page 5

Selecting Parameters and Calculation (cont.) To select a calculation (Minimum, Maximum or Average): Scroll to the middle row, and then press the RIGHT or LEFT arrow key to select the desired calculation. The min/max/ave calculations are made from the last time the meter was powered up. If no parameter is selected, all the parameters in that row remain solid (not blinking), and the Psyclone displays the current reading. Min/Max/Ave will continue to calculate while in these modes. Push the UP arrow to return to free measurement mode. Page 6 Protimeter Psyclone

Setting User Options To set up the user options to your particular requirements, firmly press and hold the SETUP key (the DOWN arrow key) for 2 seconds. The lower part of the screen appears similar to Figure 4 below. Figure 4: Setup Menu The factory default settings are: Temp - Off Psy. Cal. Options - Off Device auto off - 3 mins Back Light - 0 mins (off) Use the LEFT and RIGHT arrow keys to scroll to the desired option, and the UP and DOWN arrow keys to set the desired selection. Once selected, wait for the meter to return to measurement mode or push the button to save the change. Four options are available: Protimeter Psyclone Page 7

Setting User Options (cont.) Units F/ C You can display all temperature measurements in either F or C. (Setting C also results in displaying other parameters in metric units, such as g/kg. Setting F prompts the meter to display other parameters in nonmetric units, such as GPP or grains per pound.) Press the UP or DOWN arrow key to toggle between F and C units. Psychometric Calculations You can extend the available humidity measurements to include psychometric calculations (Wet Bulb Temperature, kcal/kg and BTU/lb, shown in Figure 2). Press the DOWN or UP arrow key to turn on (or off) the Psychometric Calculation options. When the screen refreshes, you can then select the desired calculation (see the next page). Page 8 Protimeter Psyclone

Setting User Options (cont.) Back Light You can set the back light for the LCD display to remain on from 1 to 9 minutes at a time. (If you set 0, the back light is turned off.) Use the UP and DOWN arrow keys to scroll to the desired number of minutes after the last button push. Device Auto OFF You can set the Psyclone to shut off automatically after from 1 to 9 minutes at a time. (If you set 0, the automatic shutoff is turned off.) Use the UP and DOWN arrow keys to scroll to the desired number of minutes to stay on after the last button push. Protimeter Psyclone Page 9

Using the Optional Surface Temperature Probe (#BLD7710) Note: The Surface Temperature (Surface) and Temperature Difference (Temp Diff) appear only if you are using the surface temperature probe option. To obtain surface temperatures via the optional probe: 1. Plug in the surface temperature probe on the right side of the Psyclone. 2. Scroll to the bottom row using the UP or DOWN arrow keys, and then select Surface or Temp Diff on the screen. Selecting Ambient uses the Psyclone s internal sensors. 3. Remove the black cap, exposing the metal sensing strip on the sensor. 4. Apply the metal strip on the probe to the surface you wish to measure. Page 10 Protimeter Psyclone

Using the Optional Surface Temperature Probe (cont.) In Surface mode, the reading shown will be the surface temperature. (Allow time for the reading to settle.) In Temp Diff mode, the temperature shown will be the proximity to Dew Point (when condensation will occur). For example, a reading of 5 degrees would indicate that the surface temperature is 5 degrees above the Dew Point. A reading of -5 degrees would indicate that the surface temperature is 5 degrees below the Dew Point and condensation is present. Figure 5: Optional Surface Temperature Probe with Cap Removed Protimeter Psyclone Page 11

Caring for Your Psyclone When you have finished using the Psyclone, retract the probe back into the meter. Use the carrying case to shield the Psyclone when not in use. Keep the Psyclone out of water, and away from dirt and dust. If the Psyclone has been stored in excessive heat or cold (i.e., a vehicle), allow for increased acclimation time. A low battery warning appears when the battery has only 20% of its charge. To replace the batteries, remove the panel on the rear of the Psyclone and insert two 1.5 V, AA batteries. Do not use rechargeable batteries. Error Codes E-1: Sensor probe not responding E-2: CRC checksum error If either of these codes appear, contact GE Sensing. Page 12 Protimeter Psyclone

Replacement Parts To order the parts listed below, or for additional service, contact GE Sensing at 800-833-9438 (North America), +353 61 470200 (Europe and Asia), or www.gesensing.com. Battery Cover (BAT7800) Pouch (POU8512) Belt Clip (BLD7810) Specifications Power 2 x AA 1.5v Enclosure Material Dimensions Weight Front Panel Keys Probe Humidity Measurement Range Humidity Precision ABS with silicone rubber boot ~165 mm x ~65 mm x ~30 mm (~6.5 in. x ~2.5 in. x ~1.2 in.) ~ 200 g Rubber function keys 1.0-99.0% (non condensing) ± 2% (10% to 90% @ 25 C/77 F) Protimeter Psyclone Page 13

Operating Temperature Range Probe Measurement Temperature Range Temperature Accuracy Certifications Glossary 0 to 50 C (32 to 122 F) -20 to 85 C (-4 to 185 F) ± 0.5 C (0 to 50 C, or 32 to 122 F) CE Approval, RoHS Compliance & WEEE Emissions: Class A Immunity - Annex C. Performance Criteria - Non Continuous Operation. Symbol Definition % RH The ratio of the amount of water vapor in the air at a specific temperature to the maximum amount that the air could hold at that temperature, expressed as a percentage. Page 14 Protimeter Psyclone

Specific Humidity (GPP, g/kg and PPMw) DEW POINT ( C/ F) WET BULB ( C/ F) Enthalpy kcal/kg Enthalpy BTU/lb The ratio of the mass of water vapor to the mass of dry air. For very low levels, the Specific Humidity is also expressed as parts per million by weight (PPMw). The temperature at which the air you are measuring would be saturated. Condensation would begin appear on surfaces if they are colder that the dew point temperature. The temperature of a wetted thermometer in moving air. The wet bulb temperature is a measure of the rate of evaporation which is influenced by the amount of water vapor in the air. The amount of thermal energy required to remove all the water from 1 kg of air and cool it to 0 C. The amount of thermal energy required to remove all the water from 1 lb. of air and cool it to 32 F. Protimeter Psyclone Page 15

Limited Warranty GE Sensing (GE) warrants the Psyclone thermo-hygrometer (Psyclone) against defects in material and workmanship for 24 months from the date of shipment, except, however, the sensor components of the Psyclone, which are warranted for a one year period. Products not subjected to misuse will be repaired or replaced. GE reserves the right to make changes without further notice to any products herein. GE makes no warranty, representation or guarantee regarding the suitability of its products for any particular application nor does GE assume any liability arising out of the application or use of any product or circuit and specifically disclaims all liability without limitation for consequential or incidental damages. The foregoing warranties are exclusive and in lieu of all other warranties, whether written, oral, implied or statutory. NO IMPLIED STATUTORY WARRANTY OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE SHALL APPLY. GE Sensing standard terms and conditions apply. Page 16 Protimeter Psyclone

Return Policy If a GE Sensing, Inc. instrument malfunctions within the warranty period, the following procedure must be completed: 1. Notify GE Sensing, Inc., giving full details of the problem, and provide the model number and serial number of the instrument. If the nature of the problem indicates the need for factory service, GE Sensing, Inc. will issue a RETURN AUTHORIZATION NUMBER (RAN), and shipping instructions for the return of the instrument to a service center will be provided. 2. If GE Sensing, Inc. instructs you to send your instrument to a service center, it must be shipped prepaid to the authorized repair station indicated in the shipping instructions. 3. Upon receipt, GE Sensing, Inc. will evaluate the instrument to determine the cause of the malfunction. Then, one of the following courses of action will then be taken: Protimeter Psyclone Page 17

If the damage is covered under the terms of the warranty, the instrument will be repaired at no cost to the owner and returned. If GE Sensing, Inc. determines that the damage is not covered under the terms of the warranty, or if the warranty has expired, an estimate for the cost of the repairs at standard rates will be provided. Upon receipt of the owner s approval to proceed, the instrument will be repaired and returned. Page 18 Protimeter Psyclone

USA 1100 Technology Park Drive Billerica, MA 01821-4111 Web: www.gesensing.com Ireland Sensing House Shannon Free Zone East Shannon, Co. Clare