POWERBALL HCI -T. Technical Information. POWERBALL HCI -T for enclosed luminaires.

Similar documents
POWERBALL HCI -TC. Technical Information. POWERBALL HCI -TC for enclosed luminaires.

POWERBALL HCI -T. Technical Information. POWERBALL HCI -T for enclosed fixtures.

HCI-T 70 W/942 NDL PB

HCI-T 70 W/942 NDL PB

HCI-TT 250 W/942 NDL PB

POWERBALL HCI-T. Product family datasheet. Metal halide lamps with ceramic technology for enclosed luminaires

POWERBALL HCI-T. Product family datasheet. Metal halide lamps with ceramic technology for enclosed luminaires

QT-FIT8 2X58-70/ VS20

QTi DALI/DIM / QTi GII / QTP5

LUMILUX T5 HO CONSTANT

QT-FIT8 2X58-70/ VS20

QTi DALI/DIM / QTi GII / QTP5

QTi DALI/DIM / QTi GII / QTP5

POWERSTAR HQI -TM 600 and 1000W POWERBALL HCI -TM 250 and 400W

DULUX L LUMILUX DE LUXE

DULUX L LUMILUX IMPROVED LIFETIME & SYSTEM GUARANTEE. DULUX L LUMILUX & QUICKTRONIC TECHNICAL INFORMATION 1.

The AR111 LED is ideal solution for spot lighting in shops

HALODIUM II. Product family datasheet. Outdoor flood- and spotlights. Areas of application _ Facades and monuments _ Parks

TUV Low Pressure Mercury

Residential Road_Lighting Class S5

LED Modules. Fortimo LED Line High Flux PR. 2ft 4000lm 1R NA

Light Engines. Data Sheets. Nix II Series. Oberon II Series. Pluto II Series. Titan II Series. Mercury II Series. Aries II Series.

Less power great performances

CURION 185 FIXED Colour White = MW Matte White RAL 9016 Colour Black = BL Matte Black RAL 9005 Beam Angle 80 EN60598 / EN62031 / EN62471 >25 >25.

LED LED Street Lamps. Industrial / Commercial LED "Corn" Lamps. 360 Beam Angle. Color 30=3000k 40=4000k 50=5000k 60=6000k.

Product Description TUV PL-L

SPORTS: Single Tennis court 24x11m for class III

SPORTS: Single Tennis court 24x11m for class III

Photometric Test Report

LED Lightsource-R High Bay - EU

T5 Retail Sales. 2011, September 8 data subject to change

LED Lightsource-R High Bay - EU

PrevaLED Linear Slim 2

SIROCCO. Robust high-pressure diecast aluminium housing. Computer aided design reflector. Graduated scale for accurate aiming.

FL200 Monochromatic Architectural Spot and Floodlight

Experience bright and vivid colors

LED lighting systems

Mirror with Socket

Crown Candle 30/40 Equivalent Non-dimmable / Dimmable

Airfield Lighting. For your runway and taxiway safety

EX-RECESSED CEILING LIGHT FITTINGS

5mm Infrared LED,T-1 HIR323C

LED FLOOD LIGHTING SPORTS LIGHTING CASE STUDY. Yankee Stadium. New York USA

LAMP 339-9SUGSURSUBC/S1174

Stance LED Pendant Indirect/Direct

5mm Infrared LED HIR7373B/L289

ChromaLit Extruded Linear

EALP05RDBRA0 LAMP. Features. Description. Applications. Choice of various viewing angles. Available on tape and reel. Reliable and robust

LAMP SUGC/S400-A5

204-10SDRD/S530-A3 LAMP. Features. Description. Applications. Revision 1. LifecyclePhase: Expired Period: Forever. Choice of various viewing angles

333-2SURC/H3/S530-A4 LAMP. Features. Description. Applications. 1 Ver.:2 Release Date:12/13/2016 狀態 :Approved( 正式發行 )

5mm Infrared LED EAILP05RDDB1

3mm Infrared LED,T-1 HIR204C

LED T5 - LINEAR REPLACEMENT TUBE DIRECTFIT COATED GLASS SERIES UL TYPE-A

LRD SERIES. Specification LED Retrofit Downlight

LS3L-R-D. Litespeed MOD 3 LED Recessed Slot. Ordering Guide. Key Features. Performance LITESPEED LS3L-R-D. Fixture Type: Project Name:

1224SUBC/C470/S400-A4

A high specification, high performance discharge floodlight idea for sports field and stadium lighting, both indoor and outdoor:

LED T8 U-BEND DIRECTFIT PLASTIC SERIES UL TYPE-A

A smooth design solution for a seamless look

COMFORT LED. The new TECO range

Leveraging Lighting - Increasing Your Bottom Line while Enlightening the Environment

DRIVER VOLTAGE DRIVER TYPE. DM v Low Voltage Dimming (10% - 100%) (Standard) LV - Line Voltage Dimming *Specify Voltage (120v or 277v)

DRIVER VOLTAGE DRIVER TYPE. DM v Low Voltage Dimming (10% - 100%) (Standard) LV - Line Voltage Dimming *Specify Voltage (120v or 277v)

A smooth design solution for a seamless look

LAMP 336SURSYGWS530-A3

LM LUMEN MAINTENANCE TEST REPORT

code: NEWS _EN s/p LED 2016 NEWS 02 -EN

FENCER Under Cabinet LED Light Fixture

LIMBA SUSPENDED LUMINAIRES

Technical Data Sheet 339-9SUGSURSUBC/S1182. Features. Descriptions. Applications. Device Selection Guide

CABRIO LAMPS REFLECTORS CHARACTERISTICS LUMINAIRES LIGHT DISTRIBUTION THREE SIZES, MULTIPLE PHOTOMETRIC SOLUTIONS

Graphic Arts Lamps. Metal Halide Pulse Xenon Quartz Halogen Quartz IR Heater Short Arc Xenon

POWERED BY IP66 IK08 LM-80 LED URBAN LIGHT. LED Urban Light

PORTABLE WORK LIGHT MODEL NO: CL6FS OPERATION INSTRUCTIONS PART NO: GC0315

PUBLIC LIGHTING APPROVALS NETWORK Assessment and approvals process for product suppliers

WE-EF LEUCHTEN General Catalogue Asia Paci c Edition Tennis Court Lighting

Technical data: SCHUCH quality - Your advantage:

TEST REPORT. ACCORDING TO IES LM For. Samsung Electronics Co., LTD. 1,Samsung-Ro,Giheung-Gu,Yongin-City,Gyeonggi-Do 17113, Korea

Special halogen lamps

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

LED Down Light (8 ) Dimension:

COMFORT LED. The new TECO range

Technical data: SCHUCH quality - Your advantage:

User manual. PCA EXCEL one4all with corridorfunction PCA T5 ECO lp with corridorfunction TE one4all with corridorfunction

LED 14W POLO BULKHEAD WITH MICROWAVE SENSOR

CONTOUR SPECIFICATION

The AR111 LED is ideal solution for spot lighting in shops

Knowing you re safe. Philips UV purification lamp systems offer highest reliability, enabling maximum protection of water and air quality

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES. For. EiKO Global, LLC W 84th Street, Shawnee, KS 66227

Knowing your water and air are clean

PRODUCT INFORMATION ÖLFLEX ROBUST 215 C

An Update on IEC TC 81 (Lightning Protection)

RESOLUTION MSC.94(72) (adopted on 22 May 2000) PERFORMANCE STANDARDS FOR NIGHT VISION EQUIPMENT FOR HIGH-SPEED CRAFT (HSC)

Norrsken Family Booklet

Technical Data. General specifications. Rated operating distance s n 2 mm

Mass Flows of Selected Target Materials in LED Products

Technical Data. General specifications. Rated operating distance s n 5 mm

Floodlight LED. Series Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

A60 A65 YEAR MODEL. 100 mm VT w SKU: K WARM WHITE SKU: K DAY WHITE SKU: K WHITE. 37 mm MODEL SHAPE A60 VT

Transcription:

POWERBALL HCI -T Technical Information POWERBALL HCI -T LP HPD MK page 1 of 5

General product description High intensity discharge s Metal halide s with ceramic burner POWERBALL 1 technology UV-filter technology For luminaires with protective shield, only Basic technical description Nominal wattage Cap Correlate d colour [K] Light colour code Length max. (l) Diameter max. (d) Weight per piece [g] Light centre length (a) Typical voltage 2 HCI-T 35W/830 WDL PB 35 G12 3000 830 100 20 27 56 93 0.51 HCI-T 35W/942 NDL PB 35 G12 4200 942 100 20 27 56 86 0.53 HCI-T 50W/830 WDL PB 50 G12 3000 830 100 20 27 56 n.a. n.a. HCI-T 70W/830 WDL PB 70 G12 3000 830 100 20 28 56 95 0.96 HCI-T 70W/942 NDL PB 70 G12 4200 942 100 20 28 56 91 0.99 HCI-T 100W/830 WDL PB 100 G12 3000 830 105 20 30 56 93 1.22 HCI-T 100W/942 NDL PB 100 G12 4200 942 105 20 30 56 94 1.23 HCI-T 150W/830 WDL PB 150 G12 3000 830 105 25 34 56 93 1.80 HCI-T 150W/942 NDL PB 150 G12 4200 942 105 25 34 56 92 1.85 [V] Typical current 2 [A] Performance specification 3 Rated wattage Rated system wattage 4 Luminous flux [lm] Luminous efficacy [lm/w] Colour rendering index Ra Colour renderin g level Average life (B50) 5 [h] HCI-T 35W/830 WDL PB 39 43 3700 95 85 1B 15000 HCI-T 35W/942 NDL PB 39 43 3400 87 91 1A 15000 HCI-T 50W/830 WDL PB 50 54.5 5250 105 89 1B 15000 HCI-T 70W/830 WDL PB 73 80 7400 101 89 1B 15000 HCI-T 70W/942 NDL PB 73 80 6800 93 95 1A 15000 HCI-T 100W/830 WDL PB 100 6 106 11300 113 86 1B 15000 HCI-T 100W/942 NDL PB 100 6 106 10500 105 95 1A 15000 HCI-T 150W/830 WDL PB 147 160 15100 103 89 1B 15000 HCI-T 150W/942 NDL PB 147 160 14700 100 95 1A 15000 1 Round ceramic burner for optimized efficacy 2 Refers to operation with a reference electromagnetic ballast (IEC 60923). 3 The specified values refer to operation with electronic control gear at rated wattage, unless otherwise stated. They refer to base-up burning position, in line with IEC 61167. Other burning positions may result in differing values. 4 With OSRAM POWERTRONIC PTi, PT-FIT or PTo 5 For all burning positions. In operation with electromagnetic control gear 12000 h for all burning positions. 6 OSRAM POWERTRONIC PTi and PTo drive s at 97 W. LP HPD MK page 2 of 5

Lamp lumen maintenance factor (LLMF) vs. operation hours 2000 h 4000 h 6000 h 8000 h 12000 h 15000 h HCI-T 35W/830 WDL PB 86% 82% 78% 75% 73% 71% HCI-T 35W/942 NDL PB 92% 91% 91% 89% 84% 79% HCI-T 50W/830 WDL PB 94% 91% 86% 84% 80% 76% HCI-T 70W/830 WDL PB 85% 81% 80% 78% 75% 72% HCI-T 70W/942 NDL PB 87% 81% 78% 77% 76% 69% HCI-T 100W/830 WDL PB 88% 83% 80% 79% 76% 74% HCI-T 100W/942 NDL PB 95% 90% 87% 83% 80% 75% HCI-T 150W/830 WDL PB 87% 81% 78% 75% 69% 64% HCI-T 150W/942 NDL PB 92% 85% 82% 78% 74% 69% Lamp survival factor 7 (LSF) vs. operation hours 2000 h 4000 h 6000 h 8000 h 12000 h 15000 h HCI-T 35W/830 WDL PB 99% 98% 97% 96% 80% 50% HCI-T 35W/942 NDL PB 99% 98% 97% 96% 80% 50% HCI-T 50W/830 WDL PB 99% 98% 97% 96% 80% 50% HCI-T 70W/830 WDL PB 99% 98% 97% 96% 80% 50% HCI-T 70W/942 NDL PB 99% 98% 97% 96% 80% 50% HCI-T 100W/830 WDL PB 99% 98% 97% 96% 80% 50% HCI-T 100W/942 NDL PB 99% 98% 97% 96% 80% 50% HCI-T 150W/830 WDL PB 99% 98% 97% 96% 80% 50% HCI-T 150W/942 NDL PB 99% 98% 97% 96% 80% 50% Operation conditions Burning position: any Max. permitted outer bulb [ C] Max. permitted pinch [ C] Ignition voltage min. / max. [kv p] Required control gear 8 Suitable OSRAM electronic control gear Dimming HCI-T 35W/830 WDL PB 500 350 3.6 9 / 5.0 10 ECG, CCG PTi, PT-FIT, PTo not allowed HCI-T 35W/942 NDL PB 500 350 3.6 9 / 5.0 10 ECG, CCG PTi, PT-FIT, PTo not allowed HCI-T 50W/830 WDL PB 500 350 3.0 9 / 5.0 10 ECG only PTi, PT-FIT, PTo with PTo 11 HCI-T 70W/830 WDL PB 500 350 3.6 9 / 5.0 10 ECG, CCG PTi, PT-FIT, PTo with PTo 11 HCI-T 70W/942 NDL PB 500 350 3.6 9 / 5.0 10 ECG, CCG PTi, PT-FIT, PTo with PTo 11 HCI-T 100W/830 WDL PB 500 350 3.6 9 / 5.0 10 ECG, CCG PTi, PTo with PTo 11 HCI-T 100W/942 NDL PB 500 350 3.6 9 / 5.0 10 ECG, CCG PTi, PTo with PTo 11 HCI-T 150W/830 WDL PB 550 350 3.6 9 / 5.0 10 ECG, CCG PTi, PTo with PTo 11 HCI-T 150W/942 NDL PB 550 350 3.6 9 / 5.0 10 ECG, CCG PTi, PTo with PTo 11 7 Indicates the percentage of operational s after a given period of operation time. 8 ECG stands for low frequency square wave electronic ballast. See the respective data sheet in IEC 61167 and Annexes G and H, therein. CCG stands for electromagnetic ballast (see IEC 61347). 9 For superimposed ignition with square wave electronic ballast 3.0 kv p are sufficient. 10 This limit is for safety reasons. 11 Depending on the dimming level both correlated colour and colour rendering index Ra may substantially change; average life may not increase. LP HPD MK page 3 of 5

Safety, materials and environment Compliant with safety specifications according to EN 62035 Compliant with RoHS. Only for luminaires with protective shield according to IEC 60598-1 For operation with an electromagnetic ballast 12 a protection against rectifying effect at end-of-life required Staring at operating light source to be avoided because of high brightness Product description Typical specific effective radiant UV power [mw/1000 lm] HCI-T 35W/830 WDL PB 0.46 2.7 HCI-T 35W/942 NDL PB 0.24 4.9 HCI-T 50W/830 WDL PB 0.22 6.5 HCI-T 70W/830 WDL PB 0.23 5.5 HCI-T 70W/942 NDL PB 0.12 7.2 HCI-T 100W/830 WDL PB 0.13 7.7 HCI-T 100W/942 NDL PB 0.20 11.8 HCI-T 150W/830 WDL PB 0.10 24.1 HCI-T 150W/942 NDL PB 0.15 16.5 Typical mercury content [mg] Energy labelling 13 Product description Energy efficiency class Weighted energy consumption E C [kwh/1000h] HCI-T 35W/830 WDL PB A+ 43 HCI-T 35W/942 NDL PB A+ 43 HCI-T 50W/830 WDL PB A+ 55 HCI-T 70W/830 WDL PB A+ 81 HCI-T 70W/942 NDL PB A+ 81 HCI-T 100W/830 WDL PB A+ 110 HCI-T 100W/942 NDL PB A+ 110 HCI-T 150W/830 WDL PB A+ 162 HCI-T 150W/942 NDL PB A+ 162 12 See IEC 61347. 13 According to Regulation (EU) No 874/2012 of July 12, 2012 LP HPD MK page 4 of 5

Logistics data Product description ILCOS EAN 10 EAN 40 Standard pack quantity HCI-T 35W/830 WDL PB MT/UB-35/930-H/E/SL-G12-20/90 4008321681850 4008321681867 12 HCI-T 35W/942 NDL PB MT/UB-35/942-H/E/SL-G12-20/90 4008321681898 4008321681904 12 HCI-T 50W/830 WDL PB MT/UB-50/830-H/E/L-G12-20/90 4052899031760 4052899031777 12 HCI-T 70W/830 WDL PB MT/UB-70/830-H/E/SL-G12-20/90 4008321678430 4008321678447 12 HCI-T 70W/942 NDL PB MT/UB-70/942-H/E/SL-G12-20/90 4008321678522 4008321678539 12 HCI-T 100W/830 WDL PB MT/UB-100/830-H/E/SL-G12-20/100 4008321682963 4008321682970 12 HCI-T 100W/942 NDL PB MT/UB-100/942-H/E/SL-G12-20/100 4008321682987 4008321682994 12 HCI-T 150W/830 WDL PB MT/UB-150/830-H/E/SL-G12-26/100 4008321682055 4008321682062 12 HCI-T 150W/942 NDL PB MT/UB-150/942-H/E/SL-G12-26/100 4008321682079 4008321682086 12 Typical spectral power distribution Light colour code Fig. no. 830 1 942 2 Fig. 1 Fig. 2 References Reference Brochure Metal halide s. Instructions for the use and application Brochure High Intensity Discharge s. Technical information on reducing the wattage Ray data (e.g. ASAP, SPEOS, LightTools) 3D data (e.g. Parasolid, STEP) System + guarantee available on request available on request level 3C, see LP HPD MK page 5 of 5