POWERBALL HCI -T. Technical Information. POWERBALL HCI -T for enclosed fixtures.

Similar documents
POWERBALL HCI -TC. Technical Information. POWERBALL HCI -TC for enclosed luminaires.

POWERBALL HCI -T. Technical Information. POWERBALL HCI -T for enclosed luminaires.

HCI-T 70 W/942 NDL PB

HCI-T 70 W/942 NDL PB

HCI-TT 250 W/942 NDL PB

POWERBALL HCI-T. Product family datasheet. Metal halide lamps with ceramic technology for enclosed luminaires

POWERBALL HCI-T. Product family datasheet. Metal halide lamps with ceramic technology for enclosed luminaires

QT-FIT8 2X58-70/ VS20

QT-FIT8 2X58-70/ VS20

QTi DALI/DIM / QTi GII / QTP5

QTi DALI/DIM / QTi GII / QTP5

LUMILUX T5 HO CONSTANT

POWERSTAR HQI -TM 600 and 1000W POWERBALL HCI -TM 250 and 400W

QTi DALI/DIM / QTi GII / QTP5

DULUX L LUMILUX DE LUXE

DULUX L LUMILUX IMPROVED LIFETIME & SYSTEM GUARANTEE. DULUX L LUMILUX & QUICKTRONIC TECHNICAL INFORMATION 1.

The AR111 LED is ideal solution for spot lighting in shops

HALODIUM II. Product family datasheet. Outdoor flood- and spotlights. Areas of application _ Facades and monuments _ Parks

TUV Low Pressure Mercury

Residential Road_Lighting Class S5

CURION 185 FIXED Colour White = MW Matte White RAL 9016 Colour Black = BL Matte Black RAL 9005 Beam Angle 80 EN60598 / EN62031 / EN62471 >25 >25.

LED Modules. Fortimo LED Line High Flux PR. 2ft 4000lm 1R NA

Light Engines. Data Sheets. Nix II Series. Oberon II Series. Pluto II Series. Titan II Series. Mercury II Series. Aries II Series.

Less power great performances

Product Description TUV PL-L

SPORTS: Single Tennis court 24x11m for class III

LED LED Street Lamps. Industrial / Commercial LED "Corn" Lamps. 360 Beam Angle. Color 30=3000k 40=4000k 50=5000k 60=6000k.

Photometric Test Report

SPORTS: Single Tennis court 24x11m for class III

PrevaLED Linear Slim 2

SIROCCO. Robust high-pressure diecast aluminium housing. Computer aided design reflector. Graduated scale for accurate aiming.

Airfield Lighting. For your runway and taxiway safety

LED Lightsource-R High Bay - EU

LED Lightsource-R High Bay - EU

Crown Candle 30/40 Equivalent Non-dimmable / Dimmable

LED lighting systems

Experience bright and vivid colors

EX-RECESSED CEILING LIGHT FITTINGS

T5 Retail Sales. 2011, September 8 data subject to change

LED FLOOD LIGHTING SPORTS LIGHTING CASE STUDY. Yankee Stadium. New York USA

ChromaLit Extruded Linear

Stance LED Pendant Indirect/Direct

5mm Infrared LED HIR7373B/L289

FL200 Monochromatic Architectural Spot and Floodlight

5mm Infrared LED,T-1 HIR323C

204-10SDRD/S530-A3 LAMP. Features. Description. Applications. Revision 1. LifecyclePhase: Expired Period: Forever. Choice of various viewing angles

333-2SURC/H3/S530-A4 LAMP. Features. Description. Applications. 1 Ver.:2 Release Date:12/13/2016 狀態 :Approved( 正式發行 )

A high specification, high performance discharge floodlight idea for sports field and stadium lighting, both indoor and outdoor:

5mm Infrared LED EAILP05RDDB1

3mm Infrared LED,T-1 HIR204C

LED T8 U-BEND DIRECTFIT PLASTIC SERIES UL TYPE-A

LED T5 - LINEAR REPLACEMENT TUBE DIRECTFIT COATED GLASS SERIES UL TYPE-A

EALP05RDBRA0 LAMP. Features. Description. Applications. Choice of various viewing angles. Available on tape and reel. Reliable and robust

Mirror with Socket

LS3L-R-D. Litespeed MOD 3 LED Recessed Slot. Ordering Guide. Key Features. Performance LITESPEED LS3L-R-D. Fixture Type: Project Name:

LAMP SUGC/S400-A5

FENCER Under Cabinet LED Light Fixture

LIMBA SUSPENDED LUMINAIRES

LAMP 339-9SUGSURSUBC/S1174

CABRIO LAMPS REFLECTORS CHARACTERISTICS LUMINAIRES LIGHT DISTRIBUTION THREE SIZES, MULTIPLE PHOTOMETRIC SOLUTIONS

Graphic Arts Lamps. Metal Halide Pulse Xenon Quartz Halogen Quartz IR Heater Short Arc Xenon

A smooth design solution for a seamless look

LRD SERIES. Specification LED Retrofit Downlight

A smooth design solution for a seamless look

TEST REPORT. ACCORDING TO IES LM For. Samsung Electronics Co., LTD. 1,Samsung-Ro,Giheung-Gu,Yongin-City,Gyeonggi-Do 17113, Korea

1224SUBC/C470/S400-A4

COMFORT LED. The new TECO range

Technical Data Sheet 339-9SUGSURSUBC/S1182. Features. Descriptions. Applications. Device Selection Guide

LM LUMEN MAINTENANCE TEST REPORT

POWERED BY IP66 IK08 LM-80 LED URBAN LIGHT. LED Urban Light

Technical data: SCHUCH quality - Your advantage:

Knowing you re safe. Philips UV purification lamp systems offer highest reliability, enabling maximum protection of water and air quality

WE-EF LEUCHTEN General Catalogue Asia Paci c Edition Tennis Court Lighting

code: NEWS _EN s/p LED 2016 NEWS 02 -EN

Special halogen lamps

PRODUCT INFORMATION ÖLFLEX ROBUST 215 C

An Update on IEC TC 81 (Lightning Protection)

Technical data: SCHUCH quality - Your advantage:

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

PUBLIC LIGHTING APPROVALS NETWORK Assessment and approvals process for product suppliers

Leveraging Lighting - Increasing Your Bottom Line while Enlightening the Environment

Knowing you re safe. Philips UV purification lamp systems offer highest reliability, enabling maximum protection of water and air quality

DRIVER VOLTAGE DRIVER TYPE. DM v Low Voltage Dimming (10% - 100%) (Standard) LV - Line Voltage Dimming *Specify Voltage (120v or 277v)

Knowing your water and air are clean

DRIVER VOLTAGE DRIVER TYPE. DM v Low Voltage Dimming (10% - 100%) (Standard) LV - Line Voltage Dimming *Specify Voltage (120v or 277v)

LAMP 336SURSYGWS530-A3

TECHNICAL DESCRIPTION

LED Down Light (8 ) Dimension:

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES. For. EiKO Global, LLC W 84th Street, Shawnee, KS 66227

COMFORT LED. The new TECO range

CONTOUR SPECIFICATION

CATALOGUE 2018 AIRFIELD LIGHTING

Cualiti Photo Studio

The AR111 LED is ideal solution for spot lighting in shops

User manual. PCA EXCEL one4all with corridorfunction PCA T5 ECO lp with corridorfunction TE one4all with corridorfunction

LED 14W POLO BULKHEAD WITH MICROWAVE SENSOR

In Ground Buried Uplights

Examination lamps OBSERVA ALFALED A06 L88 ALFA

XSL-360-5E. UV LED 5 mm TECHNICAL DATA. Absolute Maximum Ratings (T a =25 C) Specifications (If=20mA, T a =25 C) Drawing

Electrical Safety. Toolbox Talk

Transcription:

POWERBALL HCI -T Technical Information POWERBALL HCI -T LP HPD MK page 1 of 5

General product description High intensity discharge s Metal halide s with ceramic burner POWERBALL 1 technology UV-filter technology For luminaires with protective shield, only Basic technical description Nominal wattage Cap Correlated colour [K] Light colour code Length max. (l) Diameter (d) Weight per piece [g] Light centre length (a) Typical voltage 2 HCI-T 35W/830 WDL PB 35 G12 3000 830 100 19 27 56 93 0.51 HCI-T 35W/942 NDL PB 35 G12 4200 942 100 19 27 56 86 0.53 HCI-T 70W/830 WDL PB 70 G12 3000 830 100 19 28 56 95 0.96 HCI-T 70W/942 NDL PB 70 G12 4200 942 100 19 28 56 91 0.99 HCI-T 100W/830 WDL PB 100 G12 3000 830 105 19 30 56 93 1.22 HCI-T 100W/942 NDL PB 100 G12 4200 942 105 19 30 56 94 1.23 HCI-T 150W/830 WDL PB 150 G12 3000 830 105 25 34 56 93 1.80 HCI-T 150W/942 NDL PB 150 G12 4200 942 105 25 34 56 92 1.85 [V] Typical current 2 [A] Performance specification 3 Rated wattage Rated system wattage 4 Luminous flux [lm] Luminous efficacy [lm/w] Colour rendering index Ra Colour rendering level Average life (B50) 5 [h] HCI-T 35W/830 WDL PB 39 43 3700 95 85 1B 15000 HCI-T 35W/942 NDL PB 39 43 3400 87 91 1A 15000 HCI-T 70W/830 WDL PB 73 80 7400 101 89 1B 15000 HCI-T 70W/942 NDL PB 73 80 6800 93 95 1A 15000 HCI-T 100W/830 WDL PB 97 106 10000 103 86 1B 15000 HCI-T 100W/942 NDL PB 97 106 10500 108 95 1A 15000 HCI-T 150W/830 WDL PB 147 160 15100 103 89 1B 15000 HCI-T 150W/942 NDL PB 147 160 14700 100 95 1A 15000 1 Round ceramic burner for optimized efficacy 2 Refers to operation with a reference electromagnetic ballast (IEC 60923). 3 The specified values refer to operation with electronic control gear at rated wattage, unless otherwise stated. They refer to base-up burning position, in line with IEC 61167. Other burning positions may result in differing values. 4 With OSRAM POWERTRONIC PTi, PT-FIT or PTo 5 For all burning positions. In operation with electromagnetic control gear 12000 h for all burning positions. LP HPD MK page 2 of 5

Lamp lumen maintenance factor (LLMF) vs. operation hours 2000 h 4000 h 6000 h 8000 h 12000 h 15000 h HCI-T 35W/830 WDL PB 86% 82% 78% 75% 73% 71% HCI-T 35W/942 NDL PB 92% 91% 91% 89% 84% 79% HCI-T 70W/830 WDL PB 85% 81% 80% 78% 75% 72% HCI-T 70W/942 NDL PB 87% 81% 78% 77% 76% 69% HCI-T 100W/830 WDL PB 88% 83% 80% 79% 76% 74% HCI-T 100W/942 NDL PB 95% 90% 87% 83% 80% 75% HCI-T 150W/830 WDL PB 87% 81% 78% 75% 69% 64% HCI-T 150W/942 NDL PB 92% 85% 82% 78% 74% 69% Lamp survival factor 6 (LSF) vs. operation hours 2000 h 4000 h 6000 h 8000 h 12000 h 15000 h HCI-T 35W/830 WDL PB 99% 98% 97% 96% 80% 50% HCI-T 35W/942 NDL PB 99% 98% 97% 96% 80% 50% HCI-T 70W/830 WDL PB 99% 98% 97% 96% 80% 50% HCI-T 70W/942 NDL PB 99% 98% 97% 96% 80% 50% HCI-T 100W/830 WDL PB 99% 98% 97% 96% 80% 50% HCI-T 100W/942 NDL PB 99% 98% 97% 96% 80% 50% HCI-T 150W/830 WDL PB 99% 98% 97% 96% 80% 50% HCI-T 150W/942 NDL PB 99% 98% 97% 96% 80% 50% Operation conditions Burning position Max. permitted outer bulb [ C] Max. permitted pinch [ C] Ignition voltage min. / max. [kv] Required control gear 7 Suitable OSRAM electronic control gear Dimming HCI-T 35W/830 WDL PB any 500 350 3.6 8 / 5.0 9 ECG, CCG PTi, PT-FIT, PTo not allowed HCI-T 35W/942 NDL PB any 500 350 3.6 8 / 5.0 9 ECG, CCG PTi, PT-FIT, PTo not allowed HCI-T 70W/830 WDL PB any 500 350 3.6 8 / 5.0 9 ECG, CCG PTi, PT-FIT, PTo with PTo 10 HCI-T 70W/942 NDL PB any 500 350 3.6 8 / 5.0 9 ECG, CCG PTi, PT-FIT, PTo with PTo 10 HCI-T 100W/830 WDL PB any 500 350 3.6 8 / 5.0 9 ECG, CCG PTi, PTo with PTo 10 HCI-T 100W/942 NDL PB any 500 350 3.6 8 / 5.0 9 ECG, CCG PTi, PTo with PTo 10 HCI-T 150W/830 WDL PB any 550 350 3.6 8 / 5.0 9 ECG, CCG PTi, PTo with PTo 10 HCI-T 150W/942 NDL PB any 550 350 3.6 8 / 5.0 9 ECG, CCG PTi, PTo with PTo 10 6 Indicates the percentage of operational s after a given period of operation time. 7 ECG stands for low frequency square wave electronic ballast. See the respective data sheet in IEC 61167 and Annexes G and H, therein. CCG stands for electromagnetic ballast (see IEC 61347). 8 For superimposed ignition with square wave electronic ballast 3.0 kv are sufficient. 9 This limit is for safety reasons. 10 Depending on the dimming level both correlated colour and colour rendering index Ra may substantially change; average life may not increase. LP HPD MK page 3 of 5

Safety, materials and environment Compliant with safety specifications according to EN 62035 Compliant with RoHS. Only for luminaires with protective shield according to IEC 60598-1 For operation with an electromagnetic ballast 11 a protection against rectifying effect at end-of-life required Staring to operating light source to be avoided because of high brightness Product description Typical specific effective radiant UV power [mw/1000 lm] Typical mercury content [mg] HCI-T 35W/830 WDL PB 0.46 2.7 HCI-T 35W/942 NDL PB 0.24 4.9 HCI-T 70W/830 WDL PB 0.23 5.5 HCI-T 70W/942 NDL PB 0.12 7.2 HCI-T 100W/830 WDL PB 0.13 7.7 HCI-T 100W/942 NDL PB 0.20 11.8 HCI-T 150W/830 WDL PB 0.10 24.1 HCI-T 150W/942 NDL PB 0.15 16.5 Logistics data Product description ILCOS EAN 10 EAN 40 Standard pack quantity HCI-T 35W/830 WDL PB MT/UB-35/30/1B-H-G12-20/90 4008321681850 4008321681867 12 HCI-T 35W/942 NDL PB MT/UB-35/42/1A-H-G12-20/90 4008321681898 4008321681904 12 HCI-T 70W/830 WDL PB MT/UB-70/30/1B-H-G12-20/90 4008321678430 4008321678447 12 HCI-T 70W/942 NDL PB MT/UB-70/30/1A-H-G12-20/90 4008321678522 4008321678539 12 HCI-T 100W/830 WDL PB MT/UB-100/30/1B-H-G12-20/100 4008321682963 4008321682970 12 HCI-T 100W/942 NDL PB MT/UB-100/42/1A-H-G12-20/100 4008321682987 4008321682994 12 HCI-T 150W/830 WDL PB MT/UB-150/30/1B-H-G12-26/100 4008321682055 4008321682062 12 HCI-T 150W/942 NDL PB MT/UB-150/30/1A-H-G12-26/100 4008321682079 4008321682086 12 11 See IEC 61347. LP HPD MK page 4 of 5

Typical spectral power distribution Light colour code Fig. no. 830 1 942 2 Fig. 1 Fig. 2 References Reference Brochure Metal halide s. Instructions for the use and application Brochure High Intensity Discharge s. Technical information on reducing the wattage Ray data (e.g. ASAP, SPEOS, LightTools) 3D data (e.g. Parasolid, STEP) System + guarantee available on request available on request level 3C, see LP HPD MK page 5 of 5