BACK PRESSURE VALVE. Instructions Parts List J

Similar documents
Back Pressure Regulator

INSTRUCTIONS PARTS LIST

Color/Catalyst Dispense Valves

OPERATION. Zinc Sprayer. For Maximum Working Pressure see page 2. Rev. E

INSTRUCTIONS PARTS LIST U.S. PAT: 6,874,404; 6,516,707; 6,223,645

INSTRUCTIONS-PARTS LIST

INSTRUCTIONS-PARTS LIST

2-Liter Pressure Cup. Instructions - Parts List C

Instructions Parts List

Fluid Regulators. Instructions/Parts List C. High Pressure II 2 G. Read warnings and instructions. See page 3 for model information.

Instructions Parts List

Ball Valves, Check Valves, and Swivels

2-Quart (1.9 Liter) Pressure Cup

Fire-Ball 300 and 425 Grease Pumps

Instructions Parts List. Contents E. HIGH VOLUME Air Control Kits. 250 psi (1.7 MPa, 17.2 bar) Maximum Air Inlet Pressure

Heavy Fluid Air Spray Gun

Fluid Regulators. Instructions -Parts List. Table of Contents Z EN HIGH PRESSURE

Huskyt/ Twistorkt Package

Instructions Parts List

For use with all Graco/Gusmer spray guns (not included). 3 Gallon Solvent Tank

Fluid Pressure Regulators

Instructions Parts List

INSTRUCTIONS-PARTS LIST

Pistol-Grip Mastic Flo-Gun

Instructions Parts List

50:1 Fire Ball 300 Pump Module

OPERATION / 3Z9305G 1:1 RATIO TRITON / Spray Packages / / / List of Models, page 2 / / / 100 psi (7 bar, 0.7 MPa) Maximum Working Pressure

Dyna-Star HP Pump System

Instructions Parts List. Table of Contents H. AIR OPERATED Valve Assembly

Husky 307 Air Spray/HVLP Systems

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

INSTRUCTIONS PARTS LIST

Hotmelt/Warm Melt Heated Hose

3600 psi (25.0 MPa, 250 bar) Maximum Fluid Working Pressure

Finex Airspray Package Sprayer

Instructions Parts List

LD Series Enclosed Hose Reels

INSTRUCTIONS PARTS LIST

Volumetric Fluid Flow Meter High Pressure Meters 4000 psi (28 MPa, 276 bar) Maximum Working Fluid Pressure

M2K Mix Manifolds. Instructions - Parts B EN. Part 17D763 - M2K manifold Part 24W861 - Remote M2K manifold

APS-100 Primer Spray Module

INSTRUCTIONS PARTS LIST

Feed and Solvent Flush Kits

G700N Air Spray Package

Instructions Parts List

Instructions Parts List

Instructions Parts List

INSTRUCTIONS-PARTS LIST

WARNING: HIGH PRESSURE.

15:1 Ratio Fire-Ball Undercoater Pumps

Instructions Parts List

President 10:1 Ratio Powerflo System

INSTRUCTIONS-PARTS LIST

Series 700 Hose Reels

Instructions Parts List

Operation and Parts 3A5616A EN ADJUSTABLE FLOW CAP KIT

INSTRUCTIONS PARTS LIST

Instructions Truck Mounted Bare Hose Reel for Grease

Instructions Parts List

Instructions Parts List

RS Gun Universal Adapter Kit

Instructions-Parts List

INSTRUCTIONS-PARTS LIST

INSTRUCTIONS PARTS LIST This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE

Electric Airless Sprayer

President 10:1 Ratio Air Spray System

Therm-O-Flow Plus For all Drum Unloaders

1:1 Extruder. Operation H EN. Table Of Contents. Part No Part No

Series 350 Hose Reels

Instructions Parts List

Wall Mount Airless Packages

Cart Mounted Air Assisted Package

High Speed Spindl-Gard Lubrication System with Electric Pump

Series 500 Hose Reels

Instructions Parts List

HVLP EDGE Gun G EN

Instructions-Parts List

Husky 1050A, CSA-Certified Diaphragm Pumps

Series 250 Hose Reels

Cart-Mounted Airless Package

Pole Gun with Cleanshott Shut-off Valve and Contractort In-line Valve

Cart-Mounted Airless Package

Instructions Parts List

T2 2:1 Ratio Transfer Pump

Cart-Mounted Zinc Spray Package

Instructions Parts List

GlasCraft Catalyst Pump

Instructions Parts List

HVLP Compressor/Cart INSTRUCTIONS PARTS LIST. Related Manuals. GTS-ProCart. 240V AC 50/60 Hz

Cart Mounted, Heated Air Assisted Package

Custom PR. Operation - Maintenance 3A0241A. This machine is intended to dispense two-component, silicone-based materials only.

Instructions Parts List

Air Consumption Recommended Usage Siphon Feed

Pressure Relief Valve Instruction Manual

Instructions Parts List

Operation. Diaphragm Pump 3A2578D. Maximum Working Pressure: 125 psi (0.86 MPa, 8.6 bar) Read all warnings and instructions in this manual and in your

Husky Air-Operated Diaphragm Pump

Indy-X. Operation GC-1367K ENG. Low emission external-mix dispense gun for use with polyester resin and gel coat. For professional use only.

Model ASSEMBLY and OPERATING INSTRUCTIONS

Models: C62/63/64-A/D

Transcription:

Instructions Parts List BACK PRESSURE VALVE 306770J 300 psi (2.1 MPa, 21 bar) Maximum Inlet Pressure 180 psi (1.2 MPa, 12 bar) Maximum Regulated Pressure Model 206019, Series F For use with Monark, President and 5:1 Bulldog pumps in circulating supply systems. Controls line pressures from 0 180 psi (0 1.2 MPa, 0 12 bar). Tungsten carbide valve stem and seat. Maintains fluid pressure in circulating supply system. 7865 Read warnings and instructions. See page 2 for Table of Contents.

Table of Contents Warnings...................................... 2 Installation..................................... 4 Operation..................................... 5 Service....................................... 5 Parts......................................... 6 Dimensions.................................... 7 Technical Data................................. 7 Graco Standard Warranty....................... 8 Graco Phone Numbers.......................... 8 Warning Symbol Symbols WARNING This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions. Caution Symbol CAUTION This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the corresponding instructions.

PRESSURIZED EQUIPMENT HAZARD WARNING Spray from the gun, hose leaks, or ruptured components can splash fluid in the eyes or on the skin and cause serious injury. Do not stop or deflect fluid leaks with your hand, body, glove, or rag. Follow the Pressure Relief Procedure for your equipment if the spray tip clogs and before cleaning, checking, or servicing the equipment. Tighten all the fluid connections before operating the equipment. Check the hoses, tubes, and couplings daily. Replace worn, damaged, or loose parts immediately. Permanently coupled hoses cannot be repaired; replace the entire hose. EQUIPMENT MISUSE HAZARD INSTRUCTIONS Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury. This equipment is for professional use only. Read all instruction manuals, tags, and labels before operating the equipment. Use the equipment only for its intended purpose. If you are uncertain about usage, call your Graco distributor. Do not alter or modify this equipment. Use only genuine Graco parts and accessories. Check equipment daily. Repair or replace worn or damaged parts immediately. Do not exceed the maximum working pressure of the lowest rated system component. Refer to the Technical Data on page 7 for the maximum working pressure of this equipment. Use fluids and solvents that are compatible with the equipment wetted parts. Refer to the Technical Data section of all equipment manuals. Read the fluid and solvent manufacturer s warnings. Do not exceed the maximum working pressure of the lowest rated system component. This equipment has a 300 psi (2.1 MPa, 21 bar) maximum inlet pressure. Do not use hoses to pull equipment. Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose Graco hoses to temperatures above 82C (180F) or below 40C ( 40F). Wear hearing protection when operating this equipment. Do not lift pressurized equipment. Comply with all applicable local, state, and national fire, electrical, and safety regulations. Never use 1.1.1 trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids containing such solvents in pressurized aluminum equipment. Such use could result in a chemical reaction, with the possibility of explosion.

Installation Typical Installation F E A B KEY A B C D E F Fluid Pressure Regulator Air Spray Gun Fluid Return Line Back Pressure Valve Air Supply Line Fluid Supply Line C D 7867 CAUTION Before installing the valve, check the tightness of the capscrews (4). The screws might be loose before the valve is installed and put under pressure. See the Parts Drawing for the tightening sequence and torque value. After 24 hours, or if the valve leaks during operation, check and torque the screws again. Install the valve in the spray gun return line (See the Typical Installation). Connect the line to the 1 in. npt(f) inlet and outlet. Make sure flow agrees with IN and OUT markings on the valve body. If more than one spray station is used, the back pressure valve should be installed in the supply line after the last station to maintain proper circulating pressures in the system.

Operation The valve is adjustable to control fluid pressures in a circulating system from 0 180 psi (0 1.2 MPa, 0 12 bar). Adjust the pump pressure and back pressure valve for best spraying combination and for proper circulation of fluid. The back pressure valve controls pressure ahead of its intake. Turn the adjusting screw (16) CLOCKWISE to increase pressure, and COUNTERCLOCKWISE to decrease pressure. Flush the valve with a compatible solvent whenever the rest of the system or unit (pump, spray valve, etc.) is being flushed. Open the valve before flushing (turn the screw counterclockwise). Service WARNING Always open the valve and relieve the system pressure before servicing. Regular cleaning and inspection of the valve, based upon the degree and kind of service, is essential. Shut off the pump and relieve the line pressure by turning the valve adjusting screw counterclockwise until no spring tension is felt. To clean and inspect the valve, remove it from the line, disassemble, and clean with a compatible solvent. CAUTION Use special care in handling the valve to avoid damaging the diaphragm (11) and the hard carbide valve stem (15) and seat (19). Carefully inspect the diaphragm (11) for cracks or other damage. Before reassembling, check for chips or other dirt that could puncture the diaphragm. Check also to see if the gasket (12) needs to be replaced. Reinstall the diaphragm parts in reverse order. Torque the retaining nut (9) to 12 15 ft-lb (16 20 Nm). Carefully inspect the seat (19) for damage or wear. Obstructing dirt could cause regulated pressure to creep. Replace if necessary. Replace the seat gasket (14) when replacing the seat (19). Torque the seat to 15 20 ft-lb (21 27 Nm). To remove or install the gauge (2), use a wrench on the square portion of the gauge stud only. Use thread sealer sparingly on the male threads of the gauge when installing to prevent plugging the gauge. Reassemble the remainder of the parts in reverse order. Tighten valve capscrews (4) per sequence shown on page 6. Check the torque after 24 hours, and re-torque if necessary or if leaking occurs. Reinstall the back pressure valve in the line.

Parts Model 206019, Series F DETAIL A 1 2 3 Torque to 120 130 in-lb (13.6 14.7 Nm). See Detail A for torque sequence. Torque to 12 15 ft-lb (16 20 Nm). PTFE side down. ÎÎÎ ÎÎÎ ÎÎÎ 1 3 5 2 4 NOTE: Numbers indicate capscrew (4) tightening sequence. Torque evenly to 7 10 in-lb (0.8 1.1 Nm), then re-torque to 120 130 in-lb (13.6 14.7 Nm) 6 16 *2 11* 3 1 4 12 20 18 17 6 3 15 19 2 7 9 10 14 13 8 21 7866 Ref No. Part No. Description Qty 2* 101180 GAUGE; 0 200 psi (0 1.4 MPa, 0 14 bar) 1 3 104430 PIN, cotter; 0.06 (1.5 mm) dia, 0.75 (19 mm) lg 1 4 101682 SCREW, soc hd cap; 1/4 20 x 5/8 6 6 160033 PLATE, spring 1 7 160034 SPRING, helical compression 1 8 164864 PLATE, diaphragm 1 9 160741 NUT, special lock; diaphragm 1 10 160745 TUBE, gauge 1 11 172193 DIAPHRAGM 1 12 171912 GASKET; cellulose fibre 1 13 165750 BODY, valve (electroless nickle plated) 1 Ref No. Part No. Description Qty 14 166964 GASKET, acetal 1 15 203375 STEM, valve 1 16 186872 SCREW, adjusting 1 17 203985 SUPPORT, diaphragm 1 18 209027 CAP, valve 1 19 206275 SEAT, valve 1 20 171913 GASKET; cellulose fibre 1 21 157277 PACKING, o-ring; thiokol 1 * Recommended tool box spare parts. Keep on hand to reduce down time. Included in Repair Kit 210754.

Dimensions 3.875 (98 mm) Diameter 1 npt(f) Fluid Outlet 8 (203 mm) 5.75 (146 mm) 1 npt(f) Fluid Inlet 7865 Technical Data Maximum Inlet Pressure........................... 300 psi (2.1 MPa, 21 bar) Pressure Control Range..................... 0 180 psi (0 1.2 MPa, 0 12 bar) Approx. Maximum Flow............................... 6 gpm (22.7 liters/min) with 100 centipose fluid at 60 psi (400 kpa, 4 bar) Fluid Inlet Port..................................................... 1 npt(f) Fluid Outlet Port................................................... 1 npt(f) Weight....................................................... 4 lb (1.8 kg) Wetted Parts............................... Tungsten Carbide, PTFE, Nylon, Carbon Steel, Aluminum, Thiokol Thiokol is a registered trademark of the Thiokol Chemical Corporation.

Graco Standard Warranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco s written recommendations. This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco. This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation. THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. Graco s sole obligation and buyer s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale. Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection with accessories, equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties. In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise. FOR GRACO CANADA CUSTOMERS The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées. Graco Phone Numbers TO PLACE AN ORDER, contact your Graco distributor, or call one of the following numbers to identify the distributor closest to you: 1 800 367 4023 Toll Free 612 623 6921 612 378 3505 Fax All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. Sales Offices: Minneapolis, Detroit International Offices: Belgium, Korea, Hong Kong, Japan GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440 1441 www.graco.com PRINTED IN U.S.A. 306770 01/1963, Revised 02/2004