Operating Instructions SKYJET Compact Sub-distributor

Similar documents
Operating instructions Way valve DR4

Pump BS-B according to Atex

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE

Diaphragm Pressure Keeping Valve

Siphon vessel / Priming aid

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Diaphragm relief valve

INSTALLATION COMMISSIONING, OPERATION & MAINTENANCE MANUAL

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Brass Check Valve RDL

Operating and maintenance manual Filter and reducing station Series / 1.0

Instructions for Installation, Use and Maintenance FSI Safety Tank Shower Systems

Quincy QSG Gasends 225, 430, 580, 730 & 850

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Fixed Displacement Pump KFA for commercial vehicles in open circuits

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

FPD20 Series. Gear wheel flow sensor

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

OWNER S TECHNICAL MANUAL

Modular valve block. Operating manual Series MVB 100/200. Version BA EN Print-No TR MA DE Rev001

OPERATING INSTRUCTIONS

A17W49_MASEM_F_EN MANUAL

USER MANUAL. JET TST and JET TST S.

Installation and Operating Instructions Bypass Flow Meter DST

Pressure Limiting Valve SPVF Operating Instructions

GENERAL SAFETY INSTRUCTION GSI-M-2 STANDARD PRESSURE EQUIPMENT

Installation and Maintenance Instruction Manual

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

Operation Manual Air Saver Unit ASV5000 Series

Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0

WW-730. Pressure Sustaining/Relief Control Valve

CAST IRON SAFETY VALVE TYPE 6301

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. AWA Change-over Valve

Instrument Operating Manual

PRESSURISED PAINT CONTAINER

MANUAL. Sesame. Thermoplastic Tank Technologies

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

BIMBAR INFLATABLE PACKERS AND ACCESSORIES

for the of and the EM55-1

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Art PRESSURE REDUCER

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

Instruction Manual Contact Pressure Vacuum Gauge

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

book : t95575.fm Seite 1 Mittwoch, September 20, :10 AM. Avensys. Exposed Single Lever Mixer

Safety. Operating instructions Magnetic relief valve VAN DANGER. Contents WARNING CAUTION. Changes to edition 11.11

Installation and Maintenance Instruction Manual

MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option

Suction lance SLP / SLP Operating instructions SLP Manufacturer: Keep the operating instructions for future use!

GM Series Dual-Block Multi-Function Gas Control Valves

1 DRIVE INDUSTRIAL IMPACT WRENCH

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

MUELLER GAS. No-Blo Operations Using D-5. Drilling Machine. Reliable Connections. General Information 2

Instruction Manual Differential Pressure Transmitter

Operating Manual. Diaphragm Seals Models , 107, , 207,

Innovative Vacuum for Automation. Operating Instructions Dust Filter STF P / STF-D P.

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

GENO -Flushing Compressor Product Data Sheet F 02

CONDITIONS OF SALE AND WARRANTY

Ball valve. Operating instructions for series. Version BA Print-No TR MA DE Rev001

OPERATING INSTRUCTIONS (Translation) Rope Winch Type , , ,75

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

IX1 Spirax-Monnier International Compressed Air Filter Installation and Maintenance Instructions

USER S MANUAL Installation & Maintenance. VAX Series. High Pressure 2-way/3-way Coaxial Valve assuredautomation.

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

310 SERIES TILT-TO-LOAD ROTATOR. The Specialist In Drum Handling Equipment

Instructions for use Evacuation system compressed air injector SL 20 / SL 20 Max SL 30 / SL 30 Max

Pure-Flo Handwheel Operated Valves (903, 913, 963) Instruction Manual

Installation Instructions, Pressure Regulator Series

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

ACCU-MIX 1200 / / 26270

Steam Trap BK BK 212-ASME. Original Installation Instructions English

ML3M Monnier Miniature Compressed Air Lubricator

Declaration of Conformity as per Directive 97/23/EC

Control Valve with ZK Radial Stage Nozzle ZK 210. Original Installation Instructions English

Declaration of Conformity as per Directive 97/23/EC

3-port seat valves with externally threaded connection, PN 16

Steam Trap BK 15 (DN40, DN 50) Original Installation Instructions English

TITAN FLOW CONTROL, INC.

Installation and commissioning instructions 255 series and 256 series

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

Centrifugal Gas Separator ZGA. Operating Manual. Dimensions, weights and other technical data are subject to changes.

Operating Instructions

Dri-Line Mk3 Monnier Compressed Air Drain Trap

Pressure relief valve

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Operating Instructions in accordance with the Machines Directive 2006/42/EC

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

Composite Pistol-Type Air Needle Scaler OWNER S MANUAL

Operating instructions Two-way / three-way valves for drinking water plants

Manual Actuated Boiler Blowdown Valves

Transcription:

Operating Instructions SKYJET Compact Sub-distributor INDEX Page 1. General... 2 2. Safety... 2 4 A. Distributor Type... 5 B. Number of Outlets... 5 C. Revision... 6 D. Accessories... 6 3. Application... 7 4. Design and Function... 7 5. Specification... 7 6. Plates... 7 Page 1 of 7

1. General Prior to start up, we recommend to read these operating instructions carefully as we do not assume any liability for damages and operating troubles which result from the nonobservance of these operating instructions! Any use beyond the applications described in these operating instructions is considered to be not in accordance with the product s intended purposes. The manufacturer is not to be held responsilbe for any damages resulting from this: the user alone bears the corresponding risk. As to figures and indications in these operating instructions we reserve the right to make technical changes which might become necessary for improvements. The copyright on these operating instructions is kept reserved to the company DELIMON. These operating instructions are intended for the erecting, the operating and supervising personnel. They contain regulations and drawings a technical nature which must not completely or partially - be distributed nor used nor communicated to others without authorization for competition purposes. Company address, spare parts and service address DELIMON Branch office Arminstraße 15 Am Bockwald 4 D-40277 Düsseldorf D-08344 Grünhain-Beierfeld Phone : +49 211 77 74-0 E-mail : kontakt@bijurdelimon.com Fax : +49 211 77 74-210 www.bijurdelimon.com 2. Safety These operating instructions contain fundamental instructions which are to be observed during erection, operation and maintenance. Therefore it is absolutely necessary for the fitter and the competent qualified staff/user to read these operating instructions before installation and start-up. The operating instructions must be available at all times at the place of use of the machine/system. Not only the general safety instructions stated under this main point safety are to be observed, but also the other specific safety instructions stated under the other main points. 2.1 Identification of safety warnings in the operating instructions The safety warnings contained in these operating instructions which, if not observed, may cause dangers to people, are specially marked with general danger symbols safety sign according to DIN 4844, warning about a danger spot, in case of warning about electric voltage with safety sign according to DIN 4844, warning about dangerous electric voltage. In case of safety instructions which, if not observed, may cause damage to the machine and its function, the word ATTENTION is inserted. Instructions that are directly attached to the machine, as for example rotational direction arrow identifications for fluid connections must be observed at all events and maintained in a fully legible condition. Note: There is an increased skid risk in case of spilled/leaked out lubricants. They are to be removed at once properly. Safety sign according to DIN 4844, warning about skid risk. Page 2 of 7

2. Safety (continuation) 2.2 Personnel qualification and training The operating, maintaining, inspecting and erecting personnel must have the appropriate qualification for such work. Area of responsibility, competence and supervision of the personnel have to be regulated by the user. If the personnel do not have the necessary knowledge, they have to be trained and given instructions. This can be effected, if necessary, by the manufacturer/supplier on behalf of the user of the machine. Furthermore, the user has to make sure that the contents of the operating instructions are fully understood by the personnel. 2.3 Dangers in case of nonobservance of the safety instructions The nonobservance of the safety instructions may result in hazards to persons, to the environment and to the machine. The nonobservance of the safety instructions may lead to the loss of any claims for damages. In detail, the nonobservance may for instance lead to the following hazards: Failure of important functions of the machine/system Failure of prescribed methods for maintenance and repair Harzard to persons by electrical, mechanical and chemical influences Hazard to the environment by the leakage of dangerous substances 2.4 Safety conscious working The safety instructions stated in these operating instructions, the existing national regulations as to the accident preventation as well as possible internal working, operating and safety rules of the user are to be observed. 2.5 Safety instructions for the user/operator If hot or cold machine parts lead to dangers, these parts have to be protected against touch. Protection against touch for moving parts (e. g. coupling) must not be removed when the machine is in operation. Leakages (e. g. from the shaft seal) of hazardous goods to be delivered (e. g. explosive, toxic, hot) are to be removed in such a way that there is no danger to persons and environment. Legal rules are to be ovserved.. Hazards caused by electrial power are to be excluded (for details please refer for instance to the rules of the VDE and the local power supply companies). 2.6 Safety instructions for maintenance, inspection and installation work The user has to take care that all the maintenance, inspection and installation work is executed by authorized and qualified skilled personnel who have informed themselves adequately by thoroughly studying the operating instructions. Basically, work on the machine is only to be carried out during shut-down. It is obligatory to observe the shut-down procedure described in the operating instructions. Pumps or pump aggregates that deliver media being hazardous to health have to be decontaminated. Immediately after completion of the work, all safety and protective equipments have to be reinstalled and/or reactivated. Advice: When working with compressed air, do wear glasses. (DIN 4844 Use breathing mask) Advice: Observe EC-Safety Data Sheet for materials of consumption and additives used and use personal protective equipment. (DIN 4844 Use breathing mask) Before recommissioning, observe the points stated in section initial start-up. Page 3 of 7

2. Safety (continuation) 2.7 Unauthorized conversion and manufacture of spare parts Conversion or modifications to the machine are only permitted when agreed with the manufacturer. Original spare parts and accessories authorized by the manufacturer serve to ensure safety. The use of other parts may render the liability for consequencial losses null and void. 2.8 Unacceptable modes of operation The operational reliability of the machine supplied is only guaranteed if the machine is used in accordance with its intended purposes as per section 1 - General - of the operating instructions. The limiting values specified in the data sheet must on no account be exceeded. 2.9 Guidelines & standards 1., 2. and 3. guideline (see data sheet: R&N_2009_1_GB) 3.0 Notes on environmental protection and waste disposal In correct operation with lubricants, the components are subject to the special requirements set by environmental legislation. The general requirements for lubricants are specified in the respective safety data sheets. Used lubricants are hazardous forms of waste and therefore require special supervision in the sense of 41 paragraph 1 sentence 1 and paragraph 3 no. 1 of KrW-/AbfG (Closed-Loop Waste Management Act). Used oils must be handled in compliance with AltölV (Waste Oil Ordinance). The devices or components contaminated with lubricant must be disposed of by a certified waste management company. Records of proper waste management must be filed in conformance to NachwV (Ordinance on Waste Recovery and Disposal Records). GENERAL PRODUCT CHARACTERISTICS Sub-distributor for air-oil lubrication Compact design 2 to 6 outlets per distributor Aluminium-design (saltwater-proof) Page 4 of 7

A. DISTRIBUTOR TYPE SJK B. NUMBER OF OUTLETS 2 outlets 3 outlets 4 outlets 5 outlets 6 outlets Distributor with 2 outlets G 1/8 Distributor with 3 outlets G 1/8 Distributor with 4 outlets G 1/8 Distributor with 5 outlets G 1/8 Distributor with 6 outlets G 1/8 Page 5 of 7

C. REVISION Status A D. ACCESSORIES without 2 x Straight screwed coupling G 1/8 for pipe 6 mm steel galv. 3 x Straight screwed coupling G 1/8 for pipe 6 mm steel galv. 4 x Straight screwed coupling G 1/8 for pipe 6 mm steel galv. 5 x Straight screwed coupling G 1/8 for pipe 6 mm steel galv. 6 x Straight screwed coupling G 1/8 for pipe 6 mm steel galv. 2 x Straight plug-in connection G 1/8 for pipe 6 mm steel galv. 3 x Straight plug-in connection G 1/8 for pipe 6 mm steel galv. 4 x Straight plug-in connection G 1/8 for pipe 6 mm steel galv. 5 x Straight plug-in connection G 1/8 for pipe 6 mm steel galv. 6 x Straight plug-in connection G 1/8 for pipe 6 mm steel galv. 3. Application The SKYJET compact sub-distributor serves to dose, branch and distribute lubricant in air-oil lubrication systems. It is primarily adopted to lubricate the antifriction bearings of roll stands, continuous casting plants, roller tables and wire-rod mills. 4. Design and Function The SKYJET compact sub-distributor consists of a basic module and different inserts so that 2 to max. 6 outlets can be implemented. The inserts will be designed to suit the size of the antifriction bearings to be fed in each case. Thanks to the modular design of the compact sub-distributor, easy adaptation to different applications is possible. The basic module remains the same, just the inserts are replaced. Complete distribution of the air-oil mixture is accomplished via a connecting line. By means of fillister-head cap screws, the compact sub-distributor can be secured directly at the system; no extra holders are needed. The job and function of the SKYJET compact sub-distributor is to distribute the air-oil mixture, which is supplied under pressure, in part-flows to max. 6 possible outlets. This patented system features an inflow connection, a compressor with downstream expansion room, a turbulence chamber, a chill-out chamber and connecting metering bores. In this way, the disturbing Coanda effect (uncontrolled distribution of the air-oil mixture) is totally prevented. The sub-distributor comes with an additional filter element to prevent oil-supply failure to the bearings due to contamination. Installation position: Divider with 3, 5 and 6 outlets are not fixed to a special installation position. Please install dividers with 2 and 4 outlets in a vertical position so that the outlets are on top or bottom. If there is not enough space to do so, please install in horizontal position with the closed outlets top or bottom (see picture 1 and 2). By unscrewing the inlet the outlets can be positioned as needed. Page 6 of 7

4. Design and Function (Continued) outlets Fig 1: Distributor with 2 outlets outlets Fig. 2: Distributor with 4 outlets 5. Specifications Operating pressure (before the sub-distributor):... 3 6 bar Total air flow sub-distributor (depending on number of outlets and operating pressure)):... 2.5 5 m 3 /h Air flow per outlet (lubrication point):... 0.5 1 m 3 /h Temperature range:... - 10 to + 120 C Utilities/media... mineral oils ISO VG 32 to 680 (DIN 51519)... coc compressed air, dried and cleaned Number of outlets:... 2 to 6 Dosing volume:... according to the bearing manufacturers instructions Seals:... viton Material:... aluminium (saltwater-proof) Connecting thread, inlet:... G 1/4 Connecting thread, outlet:... G 1/8 6. Plates Type plate 26 x 52 mm (75511-1311) Page 7 of 7