ELECTRIC ACTUATORS for continuous underwater use

Similar documents
Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

4/2 way Pneumatic Solenoid Valve

THE NEW SP SERIES MAXIMUM CAPACITY MINIMUM FOOTPRINT

THE NEW SP SERIES MAXIMUM CAPACITY MINIMUM FOOTPRINT

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

Electro-Pneumatic Converter YT-940 SERIES

FAS-W. Features. Applications. Automatic condensation hygrometer

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

High-performance submersible pressure transmitter For level measurement Model LH-20

Series CGZT three-jaw grippers with T-guide

Single and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

SITRANS P measuring instruments for pressure

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

Ball valve HKSF-W100. Ball valve HKSF-W100. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany

High-performance submersible pressure transmitter For level measurement Model LH-20

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

Online data sheet FLOWSIC30 GAS FLOW METERS

Manual Power relay SR853

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

MOBILAIR M 235. Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 18.1 to 23.3 m³/min ( cfm)

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

Further technical information is available on

MOBILAIR M 210 / M 235. Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 18.0 to 23.3 m³/min ( cfm) COMPRESSORS

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

Glass tube flowmeters Series 2000

Tightness controls TC 1 3 and TC 4

Series CGCN self-centering three-jaw grippers with T-guide

Operating Instructions

WATER INJECTION SYSTEMS - CORROSION MONITORING

Valvex Valves for Mining Applications

deltaflowc deltaflowc Venturi or Probe

Pressure Measurement Single-range transmitters for general applications

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

Level switches Series LD Vibrating fork level switch for liquids and solids

Level switches Series LD Vibrating fork level switch for liquids and solids

Magnetic level switch type MR783 Instruction Manual

Flowatch Multiphase Flow Meter

Model PDT Dewpoint Transmitter

OPTIBAR P 1010 C Technical Datasheet

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E

Liquid ring vacuum pumps in compact design

VG5 Supplementary instructions

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

ASM. Asynchronous Spindle Motors. SEM Limited Faraday Way Orpington, Kent BR5 3QT United Kingdom

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

EX-RECESSED CEILING LIGHT FITTINGS

For the highest operational safety around the clock

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

Electronic Turbine Meter TERZ 94

INSTALLATION & MAINTENANCE INSTRUCTIONS - ORIGINAL VERSION AVK KNIFE GATE VALVES

NivuBar Plus II

KLINGER CONAXE Double Offset High Performance Butterfly Valve DN

Certificate of Conformity

Radiation-based Overview Page 214 FIBERTRAC Page 216 SOLITRAC Page 218 MINITRAC Page 220 POINTRAC Page 222 WEIGHTRAC Page 224

Intrinsically safe solenoid valves on/off controls - ATEX certification

RMG Meßtechnik GmbH. Publication No E

High-performance submersible pressure transmitter For level measurement Model LH-20

Liquid ring vacuum pumps single-stage

Torque Tube TB300 Digital Transmitters

IPH 2 & IPX 2. Features Type 4X & Explosion-Proof Current-to-Pressure (I/P) Transmitters. Approved for Use with Natural Gas.

C-Flow Coriolis Mass Flow Meters

Solenoid valves VZWF, force pilot operated

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases

Technical Data. Dimensions

Gripping rotary modules

Product Information. Three in One: Gas Meter Tariff Device Volume Corrector. Ultrasonic Gas Meter ECOSONIC X12

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

DIAPHRAGM GAS SAMPLING PUMPS

Level transmitter LT 100

FLAMMABLE GAS SENSOR/TRANSMITTER

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

TF- & DM-Series. Turbineflowmeter

Pressure Switches Application Guideline

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

CAST IRON SAFETY VALVE TYPE 6301

Gas density monitor With integrated transmitter Model GDM-100-TI

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

Instruction Manual Contact Pressure Vacuum Gauge

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

Liquid ring vacuum pumps in compact design

Expert Hydrostatic Level Transmitters

Willkommen. Welcome to KNF - presentation

e2c 20 - easy to connect

Arran LED Floodlight Luminaire

better measurement Simply a question of

ACTUATORS AND INSTRUMENTS

Transmitter CS 21 Operation Manual

Technical Data. General specifications. Rated operating distance s n 5 mm

DPZ-plus. Application example. Pneumatic 3-Finger Centric Grippers Sealed Grippers. Gripping force 520 N N. Sizes

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Transcription:

ELECTRIC ACTUATORS for continuous underwater use

The SA multi-turn actuator for continuous underwater use by AUMA opens new applications for electric actuators for water supply, in hydropower plants and underwater valves in general. Easy installation, low operating costs and maintenance requirements as well as the comprehensive functions of the integral actuator controls to name only some advantages of electric actuators, turning them into a true solution for underwater applications. TIGHTLY SEALED A sophisticated sealing system combined with excellent corrosion protection properties qualify AUMA actuators for underwater use. Double sealed cable glands at the electrical connection safely prevent any ingress of water. Inner seals at all housing covers, sometimes coming in pairs, as well as a solid shaft made of stainless steel complete the universal concept. EASY TO INSTALL Electric actuators just require power supply and a signal cable: They are easy to install and cost-efficient in operation. Thanks to the modular AUMA product portfolio, actuator controls are installed separately outside the flooded area. MAINTENANCE-FREE AND ENVIRONMENTALLY FRIENDLY Another asset: AUMA actuators are virtually maintenance-free. They will reliably operate under water for many years. Only after a few years of installation, AUMA recommends an inspection. Furthermore, electric actuators do not present any risk of water contamination by leaking oil. Consequently, they are an environmentally friendly alternative to hydraulic actuation technology. SA MULTI-TURN ACTUATORS FOR CONTINUOUS UNDERWATER USE 2

APPLICATIONS Hydropower applications Electric actuators for underwater used are the perfect choice for hydropower applications. They operate gate valves, butterfly valves and globe valves, for example, used in turbine control, spear head adjustment or guide vane adjustment. In in run-of-the-river power plants (ROR), used to exploit the energetic potential of water courses with low gradient levels, variable speed electric actuators are deployed for starting, synchronisation and stopping of turbines installed completely under water. In screen cleaning systems, retaining twigs and other solid foreign objects from the turbine inlet, electric actuators for underwater use are installed for ecological and economic reasons. The variable speed version enables soft and gentle approaching of end positions. Applications in water management Where both supply and sewer pipes are underground, actuator and valve are often installed in pits below ground level. If high waters are a permanent risk, actuators for underwater use will operate reliably even if flooding persists. Therefore, they are ideal for installation in monsoon areas. An explosion-proof version is available for sewage treatment plants, sewage channels or sewage pits, where fermentation gases like methane generate a risk for potentially explosive atmospheres. Civil engineering constructions for water applications and special applications The actuators are ideally suited for special operation requirements of underwater valves, for offshore installations, for flood protection at coastlines and rivers or within civil engineering constructions for water applications. 3 2018.01.11

DESIGN Electric SA multi-turn actuator AUMA SA multi-turn actuators are available in many sizes and versions and can be tailored to the individual requirements of the application. They are characterised by easy operation, robust design, reliability and a long service life. These properties are indispensable for continuous underwater use. AC In addition, actuators for continuous underwater use are subject to a comprehensive sealing scheme, preventing the ingress of water efficiently for several years. A handwheel is available as option for sizes 07.2 16.2. 1 MWG electronic control unit for non-intrusive setting The electronic control unit (MWG) is required for underwater applications. All actuator settings, including end position setting for travel and torque are made non-intrusive, i.e. without opening the housing. SA 6 7 2 Solid shaft As integral part of the sealing system, a solid shaft made of stainless steel instead of a hollow shaft is used to transmit the torque to the valve. 5 2 3 Valve attachment Output drive types B, D, B3D and DD can be used for valve attachment. B1 and B2 are directly integrated as bore with keyway into the solid shaft; B3, B4 and D require an additional output drive sleeve. B3D and DD are designed as special shafts. 1 3 4 4 Double sealed bearing flange Additional inner seals avoid ingress of water into the actuator. 5 Double sealed frame The proven AUMA double sealed frame tightly seals the electrical connection towards the actuator. 6 Special cable glands Double sealed cable glands also provide safety at the electrical connection. 7 Special wiring A special cable set is used for linking actuator and actuator controls, which is perfectly suited for continuous underwater use and UV resistant.

SERVICE CONDITIONS AC integral actuators controls AC actuator controls are mounted separately outside the water while cables connect them to the actuator. The state-of-the-art actuator controls assume communication control between DCS and actuator. Actuator controls are available with various interfaces to the DCS allowing both parallel signal transmission and fieldbus communication. Supported are among others Profibus DP and Profinet, Modbus RTU and TCP/IP, DeviceNet, Foundation Fieldbus as well as HART and WirelessHART. Integral local controls also allow for direct actuator operation. Advanced diagnostic functions enable preventive maintenance and integration of actuators into asset management systems. SAV variable speed actuator (option) SAV variable speed actuators with ACV integral actuator controls are also available as version for underwater use. Operating speed can be adapted across the travel for these actuators. Soft start and gentle approaching of end positions as well as modulating duty with utmost positioning accuracy and fast emergency operations are therefore also possible. ENCLOSURE PROTECTION AUMA actuators for continuous underwater use fulfil the requirements of improved enclosure protection IP68-C15. The maximum permissible head of water is 15 m. As an option, heads of water up to 60 m as IP68-C60 are possible. In explosion-proof version, the actuators are supplied in IP68-C8 enclosure protection for heads of water up to 8 m. CORROSION PROTECTION AUMA s TÜV certified corrosion protection scheme with two-layer powder coating is complemented by an additional coat of wet paint as well as screws, name plates and outside shafts made of stainless steel. The devices are suitable for the following ambient conditions in accordance with EN ISO 12944-2: > > C5-M (very high, marine, coastal and offshore areas with high salinity, almost permanent condensation and with high pollution) > > Im1 (fresh water) > > Im2 (sea or brackish water) > > Im3 (soil) EXPLOSION PROTECTION Actuators in explosion-proof version offer the following explosion protection according to ATEX 2014/34/EU: > > II2G Ex de IIC T4 or T3 Gb > > II2G c IIC T4 or T3 > > II2D Ex tb IIIC T130 C or T190 C Db IP6x TECHNICAL DATA The following technical data is for reference only. For detailed data, please refer to the separate technical data sheets. Combination with AUMA gearboxes (option) AUMA gearboxes are also approved for continuous underwater use. Should a part-turn actuator be required for operation of a ball valve or butterfly valve, the SA multi-turn actuator can be combined with a GS part-turn gearbox. Multi-turn actuator type Torque Output speed SA 07.2-UW SA 16.2-UW SAEx 07.2-UW SAEx 16.2-UW SAV 07.2-UW SAV 16.2-UW SA 25.1-UW SA 30.1-UW 10 Nm 1,000 Nm 4 rpm 180 rpm at 50 Hz SAR 07.2-UW SAR 16.2-UW SAREx 07.2-UW SAREx 16.2-UW SARV 07.2-UW SARV 16.2-UW SAR 25.1-UW SAR 30.1-UW Valve attachment F07 F16 Mains voltage for 3-phase AC Cable length Ambient temperature 50 Hz: 230 V, 380 V, 400 V, 415 V, 500 V 60 Hz: 220 V, 380 V, 400 V, 440 V, 460 V, 480 V Permissible variation of mains voltage: ±10 % Permissible variation of mains frequency: ±5 % Further mains voltages on request. Max. 100 m between actuator and AC 01.2 actuator controls Weatherproof 30 C to +70 C Explosion-proof: 30 C to +40 C / +60 C 5

AUMA Riester GmbH & Co. KG Aumastr. 1 79379 Muellheim Germany Tel +49 7631 809-0 Fax +49 7631 809-1250 info@auma.com AUMA subsidiaries and representatives are implanted in more than 70 countries. For detailed contact information, please refer to our website. www.auma.com Subject to changes without notice. The product features and technical data provided do not express or imply any warranty. Y007.332/003/en/1.18 Certificate Registration No. 12 100/104 4269