Rapid and Reliable Detection of Dissolved Gases in Water

Similar documents
Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:

Automated Determination of Dissolved Gases in Water Anne Jurek

ASTM WK Standard Test Method for Dissolved Gases. Anne Jurek Applications Chemist

Automated Determination of Dissolved Gases in Water By Headspace Calibration of Mixed Gases Anne Jurek

OMCL Network of the Council of Europe QUALITY ASSURANCE DOCUMENT

GCMSD-Headspace Analysis SOP

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Your local gas generation partner. Precision series Modular gas generation solution for GC.

ASTM 3612/TOGA/Dissolved Gas GC Revised October 2013

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more!

Multiple Gas#5 GC configuration Jan 2016

Simple and Worry Free Gas Filters

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

Application Note. Rapid performance verification of AZURA systems with refractive index detector. Summary. Introduction

Gas Clean. Filters. Delivering Clean Gases for GC and GC/MS Operation

Experiment GC : Analysis of BTEX by GC-FID

Ghost Peaks: How to Fix a Haunting Problem. Jacob A. Rebholz Teledyne Tekmar VOC Product Line Manager

Pycnomatic ATC For solids and powders density

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

CORESTA RECOMMENDED METHOD Nº 67

Comparative analysis of mass spectral matching for confident compound identification using the Advanced Electron Ionization source for GC-MS

Jaap de Zeeuw Restek Corporation, Middelburg, The Netherlands. Copyrights: Restek Corporation

Retention Time Locking: Concepts and Applications. Application

Thermo Scientific TRACE 1300 Series Gas Chromatograph. Evolve into GC 2.0. powerful breakthroughs

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

extraction of EG and DEG from the matrix. However, the addition of all diluent at once resulted in poor recoveries.

Analysis of Melamine and Cyanuric Acid in Food Matrices by LC-MS/MS

Simplified Backflush Using Agilent 6890 GC Post Run Command Application Note

Agilent 7697A Headspace Sampler

Increasing the productivity of ICP-OES with the Thermo Scientific Qtegra ISDS Software

Quantitative Analysis of Hydrocarbons by Gas Chromatography

APPLICATION NOTE. Fast Analysis of Coal Mine Gas Using the INFICON 3000 Micro GC ABSTRACT

Gas Chromatography. MS Vent Enhancement to the PreVent System to Optimize Operation with the TurboMass, TurboMass Gold, and Clarus 500 GC/MS Systems

Upgrading Bio-Plex Manager 4.1, 5.0, or 6.0 Software to Bio-Plex Manager 6.1 Software

Gas Chromatographic Applications of the Dielectric Barrier Discharge Detector

Optimizing Vial Pressurization Parameters for the Analysis of <USP 467> Residual Solvents Using the 7697A Headspace Sampler

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

New improved robot for gas kinetics

AREA TOTALS OECD Composite Leading Indicators. OECD Total. OECD + Major 6 Non Member Countries. Major Five Asia. Major Seven.

Demystifying the Process of Calibrating your Thermal Desorption Gas Chromatography System using Compressed Gas Standards.

Flare Gas Composition Analysis and QA/QC Lessons Learned and Lessons Lost SPECTRUM ENVIRONMENTAL SOLUTIONS, LLC 1

High Automation of Thermo Scientific FlashSmart CHNS/O Analyzer using the MultiValve Control (MVC) Module

5890II GC Standard Operating Procedure 9/2/2005

Varian 3300 Gas Chromatograph Abbreviated Operating Instructions

no peaks missing peaks too small peaks increasing retention decreasing retention

Versatility. Accuracy. Compact. Versa. Automated Headspace Vial Sampler

ISO INTERNATIONAL STANDARD

Determination of Dissolved Gases in Ground Waters. By Ray Martrano Laboratory Director Seewald Laboratories Inc.

Low-Pressure Retention Time Locking with the 7890A GC. Application. Authors. Abstract. Introduction HPI

Gas chromatographic determination of 1,4-dioxane at the

Happiness trends in 24 countries,

Organic Elemental Analysis Series II CHNS/O Elemental Analyzer. proven performance. reliable results

Standard Test Method for Residual Acrylonitrile Monomer Styrene-Acrylonitrile Copolymers and Nitrile Rubber by Headspace Gas Chromatography 1

DETERMINATION OF TETRAHYDROTHIOPHENE IN AMBIENT AIR BY GAS CHROMATOGRAPHY WITH A PFPD DETECTOR COUPLED TO A PRECONCENTRATION TECHNOLOGY

THE WORLD COMPETITIVENESS SCOREBOARD 2011

A New GC/MS System Designed for Helium Carrier Gas Conservation

Degassing ERC KK Saitama, Japan

Considerations and Best Practices for Maintaining Your Agilent GC s Split/Splitless Injection Port

SOP: Buck Scientific BLC-20P HPLC Operation

Buck Scientific, Inc.

(2 pts) Draw the line of best fit through the data and estimate the concentration of Fe in your sample solution.

Impact of Air Leaks on the Productivity of GC and GC/MS Systems

Applied Technology and Best Practices in CEE. Conference

CHM Gas Chromatography: Our Instrument Charles Taylor (r10)

SRI 8610C Gas Chromatograph Multiple Gas #3 GC configuration

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

Three Columns Gas Chromatograph Analysis Using Correlation between Component's Molecular Weight and Its Response Factor

TROUBLESHOOTING. Dwell Volume Revisited. Gradient transfer does not have to be problematic.

Using the PreVent System in Time-Saver Mode with the AutoSystem XL Gas Chromatograph and the TurboMass Mass Spectrometer

May 1, By John Heim,Doug Staples

This standard is due for Five Year Review. This process is required by the SEMI Regulations to ensure that the standard is still valid.

Organic Elemental Analysis Series II Nitrogen Analyzer. proven performance. reliable results

Determination of Oxygenates in Gasoline by Gas Chromatography and Oxygen Selective Flame Ionization Detector Method

Extend the time window for the detection of low level anabolic androgenic steroids and their metabolites

Addressing the World Shortage of Helium

FROG-4000 TM Chemical Analysis System

Zebron Gas Management

n Budget constraints n Limited benchspace n Interest in running magnetic n User-friendly data management n Benefits resulting from a

Analysis of Melamine and Cyanuric Acid in Food Matrices by LC-MS/MS

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

LINEAR TRANSFORMATION APPLIED TO THE CALIBRATION OF ANALYTES IN VARIOUS MATRICES USING A TOTAL HYDROCARBON (THC) ANALYZER

System Overview. TCD Detector temperature setpoint Regulator

Advancements in Gas Chromatography Analyzers - Keeping up with New Technology. Chuck Runkle Gas Phase Product Specialist ASTS June 2013

FROG-4000 TM Chemical Analysis System

Bernhard Thomas September EnCal 3000 prochain Energy in Gas with ROI

Acclaim RSLC. (Rapid Separation Liquid Chromatography)

Agilent G Rebuilt Electron Capture Detector

This GC has two columns (I think new columns can be ordered from Restek)

MMS Mercury Monitoring System for Natural Gas

M/s. Thermo fisher Scientific

Carrier Gases in Capillary GC

Gasket material and seal integrity in Thermo Scientific 2D Barcoded Storage Tubes

Weiyi Zheng, Xiaoxia Dong, Evan Rogers, Jimmie C. Oxley, and James L. Smith*

Trace-Level Analysis of Metanephrines in Plasma by HILIC LC-MS/MS

Svensk läkemedelsstandard

Chemical Analysis for Methyltestosterone

Development of DMS and Acetonitrile, and Formaldehyde gas standards. Gwi Suk Heo, Yong Doo Kim, Mi-Eon Kim, and Hyunjin Jin

FROG-5000TM Chemical Analysis System User s Manual

Transcription:

Rapid and Reliable Detection of Dissolved Gases in Water Andrea Caruso and Massimo Santoro Thermo Fisher Scientific, Milan, Italy Application Note 005 Key Words Chromeleon CDS, Environmental, Fracking, Gas Chromatography, GC, Headspace, Hydraulic Fracturing, Methane, TRACE 0, TriPlus 00, Water Quality Goal To describe a rapid and reliable gas chromatography method for identifying and quantifying methane, ethane, ethylene, and propane in waters affected by hydraulic fracturing operations. Introduction Hydraulic fracturing, or fracking, is a well stimulation technique in which water is typically mixed with sand and chemicals and injected at high pressure into a wellbore to create small (generally less than mm) fractures to maximize fluid removal and well productivity. This technique enables the removal of large amounts of formerly inaccessible hydrocarbons. However, the gases liberated using this method may contaminate water reservoirs and have become a controversial environmental and health matter. Monitoring the gas content of affected waters is one way to assess the environmental impact of fracking on an area. The U.S. Congress has instructed the U.S. Environmental Protection Agency not to regulate hydraulic fracturing, thus some individual states are developing their own regulations. Recently, several states finalized analysis requirements for baseline environmental monitoring of waters prior to hydraulic fracturing. This baseline monitoring aims to identify local water contaminants so that changes can be assessed post hydraulic fracturing to conclusively demonstrate that hydraulic fracturing alone (and not another process, such as mining) was responsible for detrimental impacts on the water. Different approaches are available for measuring the gas content in water. The most common method is that outlined by the industry standard SOP RSK-75, which tests for dissolved gases via static headspace gas chromatography and then calculates results according to Henry s Law, converting the concentration in the headspace into the partial pressure of the gas and using it to calculate the aqueous gas concentration. Another possible approach, adopted in this application note, is to saturate water with a gas standard or a mix of gases and use that water to build a calibration curve via sequential dilution. This approach is currently being validated by the American Society for Test Methods (ASTM). Sample and Standards Preparation Water samples are collected directly into a 0 ml headspace vial without leaving any headspace. Cap vials immediately and remove 0 ml of water immediately before the analysis. Prepare standards by bubbling gas standards into a 500 ml flask filled with deionized (DI) water in a temperature controlled bath at C. To achieve saturation of the water, use a flow of ml/min for two hours. Completely fill a 0 ml headspace vial with saturated water and cap immediately without leaving headspace in the vial. This sample is referred to as the bulk sample. Take aliquots were from the saturated bulk sample using a valve syringe. These aliquots are used to build the calibration curve by spiking increasing volumes of the bulk sample into blank DI water samples.

Method Setup A method was developed for the Thermo Scientific TriPlus 00 Headspace Autosampler and the TRACE 0 Gas Chromatograph (Table ). Recommended Instrument Conditions TriPlus 00 HS Autosampler Vial Equilibration Time: 5 min Oven Temperature: 70 C Manifold Temperature: 80 C Transfer Line Temperature: 80 C Vial Pressurization: Pressure mode, bar, 0. min equilibration time Loop Filling Mode: Pressure mode, 0.5 bar, 0. min equilibration time Injection: Standard mode for 0.5 min Purge Time: 0.5 min Purge Flow: 50 ml/min TRACE 0 GC Injection Volume: ml (standard Loop) Liner: Headspace liner (P/N 5A5) Column Type: Thermo Scientific TracePLOT TG-Bond Q 5 m, 0.5 mm (P/N 600-60) Column Oven: Initial 5 C, hold min Ramp 6 C/min to 00 C, hold min Carrier Gas: Helium SSL Injector: 00 C; split mode with a split ratio of 0: Column Flow: Constant flow at 5 ml/min Instant Connect Electron FID Temperature: 50 C Gas Conditions: Standard Methods The TRACE 0 GC system is equipped with one Instant Connect Split/Splitless (SSL) injector with a headspace liner (P/N 5A5) and an Instant Connect Electron Flame Ionization Detector (FID). The column used is a TracePLOT TG-Bond Q 5 m, 0.5 mm (P/N 600-60). The gas standards used for calibration may be ordered from Air Liquide. The data are collected and processed using the Thermo Scientific Dionex Chromeleon 7. Chromatography Data System (CDS) software. Results and Discussion The saturation time was optimized by preparing the highest methane calibration standard at 0-minute intervals, while continuously flowing DI water (Figure ). Other apparatuses and conditions may lead to different results in terms of saturation times. Area 5 0 Figure. Optimization of saturation times.,800 pa 0 0 5 00 0 Hours Figure. Chromatogram of the four gases analyzed (highest calibration point). In order from left to right, the peaks represent methane, ethylene, ethane, and propane. 0 pa 5.5 0 Figure. Chromatogram of the four gases analyzed (second calibration point, 0 µl added). Minutes Peaks:. Methane. Ethylene. Ethane. Propane 5 6 7 8 8.5 5 6 Minutes Peaks:. Methane. Ethylene. Ethane. Propane The plot-type column used for this experiment is ideal for effectively retaining and separating compounds such as the gases analysed here. The FID guarantees excellent sensitivity and a wide range of linearity. Chromatograms of the analyzed gas mixture are shown in Figures and.

Two calibration curves were built. The calibration curve for low-level concentrations was suitable for detection of minimum traces of the analytes in the samples and assessing the sensitivity of the system. Another calibration curve was built for higher concentration intervals, including the saturation level most suitable for screening real samples. Calibration curves were built by adding aliquots of saturated water directly to 0 ml of DI water in 0 ml vials. For low level detection, aliquots of 5, 0, 5, 50, and 00 µl of saturated water were added. For the high level curve, aliquots of 5, 50, and 00 µl and, 5, and 0 ml of saturated water were used. The gas content of each calibration point was calculated from the solubility of the gases at C, the temperature at which the standards are prepared. Solubility of the tested gases was: Methane: mg/l Ethylene: 9 mg/l Ethane: 6 mg/l Propane: 77 mg/l Tables and report the gas concentrations for each calibration point. Table. Concentration at the calibration points for the low-level calibration curve. Level Level Level Level Level 5 Methane 57 5 0 Ethylene 75 9 70 75 90 Ethane 0 6 55 0 60 Propane 8 77 9 85 770 Table. Concentration at the calibration points for the high-level calibration curve. Level Level Level Level Level 5 Level 6 Methane 57 5 0..5 Ethylene 70 75 90.9 7.5 9 Ethane 55 0 60 6..0 6 Propane 9 85 770 7.7 8.5 77

Figure. Low-level calibration curves for methane and ethylene. Figure 5. Low-level calibration curves for ethane and propane. The results of the calibration show good performance in terms of linearity with a r value above 0.99 for each one of the tested gases (Figures 6). Table. High-level calibration results for the four gases. Analyte r Methane 0.998 Ethylene 0.998 Ethane 0.998 Propane 0.995 Figure 6. High-level calibration curve for methane.

Conclusion This application is a viable solution for monitoring dissolved gases in water. The analytical procedure and sample preparation are simple and straightforward. Sample conservation and custody are the primary concerns. This method can be used to detect and quantitate both low and high levels of dissolved gases in water samples, making it an excellent option for testing possible impacts of hydraulic fracturing as well as gases in water from surface, non-well stimulated sources. The 0-position tray of the TriPlus 00 HS autosampler coupled with the exclusive modularity concept of the TRACE 0 GC offer high throughput capabilities with virtually no downtime for maintenance or switching to other analyses. Altogether, the system is a simple, robust and reliable option for performing this type of analysis in an unattended fashion. Application Note 005 References. Sample Preparation and Calculations for Dissolved Gas Analysis in Water Samples Using GC Headspace Equilibration Technique; U.S. Environmental Protection Agency, RSKSOP-75, Revision No., May 00. www.thermoscientific.com/gcms 0 Thermo Fisher Scientific Inc. All rights reserved. ISO is a trademark of the International Standards Organization. All other trademarks are the property of Thermo Fisher Scientific and its subsidiaries. This information is presented as an example of the capabilities of Thermo Fisher Scientific products. It is not intended to encourage use of these products in any manners that might infringe the intellectual property rights of others. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. Thermo Fisher Scientific S.p.A. Milan, Italy is ISO 900:008 Certified. Africa + 50 0 Australia +6 9757 00 Austria + 80 8 06 Belgium + 5 7 Canada + 800 50 87 China 800 80 58 (free call domestic) 00 650 58 AN005-EN 09S Denmark +5 70 6 60 Europe-Other + 50 0 Finland +58 9 9 000 France + 60 9 8 00 Germany +9 60 08 0 India +9 67 99 Italy +9 0 950 59 Japan +8 5 5 900 Korea +8 0 8600 Latin America + 56 688 8700 Middle East + 50 0 Netherlands + 76 579 55 55 New Zealand +6 9 980 6700 Norway +6 8 556 68 00 Russia/CIS + 50 0 Singapore +65 689 90 Spain + 9 85 965 Sweden +6 8 556 68 00 Switzerland + 6 76 77 00 UK + 555 USA + 800 5 75