ADC. Sphygmomanometer Accessories. Directions for Use, Care, & Maintenance AMERICAN DIAGNOSTIC CORPORATION

Similar documents
Aneroid Sphygmomanometer. Use, Care, & Maintenance

General Warnings! A warning statement in this manual identifies a condition or practice which, if not corrected or discontinued immediately could lead

Diagnostix TM Aneroids

USE, CARE & MAINTENANCE DIAGNOSTIX TM 972 MERCURIAL BLOOD PRESSURE INSTRUMENT

DIAGNOSTIX TM 922 MERCURIAL BLOOD PRESSURE INSTRUMENT. Use, Care, & Maintenance

Wallmax Professional Aneroid Sphygmomanometer Model 222 User Manual

INSTRUCTIONS. Manual Home Blood Pressure Monitor MODEL Stethoscope Chestpiece. Cuff. Bulb

TECHNICAL CHARACTERISTIC CT 071

HOME BLOOD PRESSURE KIT INSTRUCTIONS TRILINGUAL INSTRUCTION GUIDE MODEL UA-100

Model AUTOMATIC UPPER ARM Blood Pressure Monitor

Semi-Automatic Blood Pressure Monitor with Memory

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

Introduction. Table of Contents. Automatic Wrist Blood Pressure Monitor With Voice-Guided Operation. Model No.: BP5K

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

Digital Ear Thermometer

Blood Pressure Cuffs

Model ASSEMBLY and OPERATING INSTRUCTIONS

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

VER: A00. Model No:BA2010

CELEBRATING 150 YEARS Accuracy starts in the name SPHYGMOMANOMETERS

Endo-Flush Order # ZUTR30004 OPERATION MANUAL. Zutron Medical, LLC W 98 th St #40-27 Lenexa, KS Phone Fax

DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER)

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

Instruction Manual for Configura Cushionair Portable Pump

Paradise Pump Series Operator s Manual

Invacare Twilight II Nasal Mask

Vevazz. Operation Manual. Vevazz, LLC Rancho California Road. Suite Temecula, CA Phone: (773) Fax: (888)

FLOWMETER MODELS: 1MFA, 4MFA, 6MFA and 8MFA Series SAVE THESE INSTRUCTIONS

4-in-1 Professional Inflator Kit

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Inflatable Stand Up Paddle Board Manual

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

AND OPERATION INSTRUCTIONS

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

Sports Wrist Digital Blood Pressure Monitor Item #

Fingertip Pulse Oximeter

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

USER MANUAL SAVE THESE INSTRUCTIONS. Manuals available on our Website;

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

NITRONOX SCAVENGER SYSTEM USER S MANUAL / INSTRUCTIONS

FLANGED TWO-PIECE BALL VALVES

Research Grade Blood Pressure Transducer User's Manual

Maintenance and Calibration

Blood Pressure Monitor

453 Series Steam Heated Vaporizing Regulator

EasyLife INSTRUCTIONS FOR USE. Respironics Inc Murry Ridge Lane Murrysville, PA USA JDH 3/25/10

TactAir PCP Fill Kit/Adapter. Operation Manual

Dual Release Walkers 6291 Series. 1 General. 1.1 Symbols WARNING

Installation Instructions Air Compressor Part # 2780, 2781

Please Do Not Return This Product To The Store!

STANDARD OPERATING PROCEDURE ARTSANA MERCURY SPHYGMOMANOMETER

PC1131 Electric Air Compressor

User s Guide. VetPro 5000 Wall / Cabinet & Table Mount Dental Delivery System. For Models: Rev L (11/10/15)

RIK Fluid Overlay INSTRUCTIONS FOR USE

Model UB-328. Wrist Digital Blood Pressure Monitor. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni

ESTABLISHED OVER 150 YEARS FROM Accuracy starts in the name SPHYGMOMANOMETERS

Non-Invasive Blood Pressure (NIBP)

Operators Manual. Supera Wall Mount Anesthesia Machines. Models: M2300 M2500. (All shown with optional equipment) M2300 M2500

CSA Sample Draw Aspirator Adapter Operator s Manual

Owners Manual Models: 075-AQF-CX. Aquatrol Backwashing Catalytic Carbon Filter. Visit us online at.

3.1.3 Weight. Frequency. Weight is obtained at the baseline examination and annually. Equipment

Digital Display large color coded LED display is easy to read precise measuring shows actual cuff pressure

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

Med Aire Alternating Pressure Pump and Pad System

Push-To-Set Intermittent Suction Unit (PTS-ISU) Instructions for Use

FLANGED TWO-PIECE BALL VALVES

M3-LED. Operator s Manual. Operator s Manual MADE IN THE USA USA

the typical anatomy of the ear canal. The eartips should point in a forward direction as you insert them into your ear canals.

3M Littmann Classic II S.E. Stethoscope

6 digital caliper with case

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

Pressure Injection Cell Operator s Manual

DPC-30 DPC-100. Reference Manual

U S E R M A N U A L. Model: PM4300 Series SAVE THESE INSTRUCTIONS

TJF-Q180V Cleaning and Disinfection Checklist

Tourniquet Systems Pressure Infusion

J Air and Water Kit Instructions Part# 02584

Monster Windy City Leopard

Frigitronics CRYO-PLUS

User Manual. Hopkins IMPACT Digital Wrist BP RELATED ITEMS. Item #526014

INFUSION SYSTEM (110V) (220V) USER S MANUAL

Corning Step-R. Repeating Pipettor. Instruction Manual

BlenderBuddy 2. Operating Manual & Instructions For Use ENGLISH R233M01 REV. A

Hemorrhoid Multiple Band Ligator Set Instructions for Use

SC505 Sof Care Inflator. Operating Instructions and Service Manual

Master Classic II Stethoscope

DRAFT U S E R M A N U A L CAUTION. Model: 19MFA1001 Series. Federal (USA) law restricts this device to sale by or on the order of a physician.

INSTRUCTION MANUAL. Automatic Blood Pressure Monitor with Fit Cuff. =Fit Cuff=!"#$% IA1B. Model

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

REF CH-302B IDENTIFICATION OF PARTS

Oxygen Dialflow Meter. Instructions for Use

Operating Manual. Check and Go Disposable Medical Depot, Inc Port Washington N.Y

Digital Blood Pressure Monitor for the Upper Arm INSTRUCTION MANUAL

CONTENTS SPECIFICATIONS GENERAL INFORMATION RECOMMENDED USE OPERATING PRINCIPLE TIPS ON TAKING YOUR BLOOD PRESSURE 3-4 BATTERY INSTALLATION

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

J800 HOPE BUOYANCY COMPENSATOR OWNER S MANUAL

RG3100 and RG3100Ice Regulator System

D Series Air and Water Kit Part# 02550

Transcription:

ADC Sphygmomanometer Accessories Directions for Use, Care, & Maintenance AMERICAN DIAGNOSTIC CORPORATION 1

ADC Sphygmomanometer Replacement Parts (manometer, cuff, bladder, bulb and valve) Manometer Intended Use: ADC blood pressure manometers are designed to be used with ADC and compatible noninvasive blood pressure cuffs. They are intended for use with compatible inflation systems and in conjunction with a stethoscope to obtain manual blood pressure readings. Symbol Definitions The following symbols are associated with your ADC Sphygmomanometer: Symbol Definition Important Warning/Caution Not made with natural rubber latex Circumference Size Conforms to EU Standards Symbol Definition F Authorized European Represenative s Information Manufacturer s Information Temperature Limit Humidity Limitation General Warnings: WARNING: If this equipment is modified, appropriate inspection and testing must be conducted to ensure its continued safe use. WARNING: This Product May Contain A Chemical Known To The State of California To Cause Cancer, Birth Defects, Or Other Reproductive Harm. WARNING: Do not allow a blood pressure cuff to remain on patient for more than 10 minutes when inflated above 10 mmhg. This may cause patient distress, disturb blood circulation, and contribute to the injury of peripheral nerves. WARNING: Do not apply cuff to delicate or damaged skin. Check cuff site frequently for irritation. 2

WARNING: Safety and effectiveness with neonate cuff sizes 1 through 5 is not established. WARNING: Only use the cuff when the range markings indicated on the cuff show that the proper cuff size is selected, otherwise erroneous readings may result. WARNING: Allow space between patient and cuff. Two fingers should fit in this space if the cuff is correctly positioned. WARNING: Do not apply cuff to limbs used for IV infusion. WARNING: Patient should remain still during measurement to avoid erroneous readings. WARNING: If luer lock connectors are used in the construction of tubing, there is a possibility that they might be inadvertently connected to intra-vascular fluid systems, allowing air to be pumped into a blood vessel. Immediately consult a physician if this occurs. CAUTION: To obtain the greatest accuracy from your blood pressure instrument,it is recommended that the instrument be used within a temperature range of 50 F (10 C) to 104 F (40 C), with a relative humidity range of 15%-85% (non-condensing). CAUTION: Manometer pressure range is 0 mmhg to 300 mmhg. CAUTION: Extreme altitudes may affect blood pressure readings. Your device has been designed for normal environmental conditions. CAUTION: This product will maintain the safety and performance characteristics specified at temperatures ranging from 32 F to 104 F (0 C to 40 C) at a relative humidity level of 15% to 85%. CAUTION: Do not iron cuff. CAUTION: Do not heat or steam sterilize cuff. Connecting the manometer to the inflation system: Pocket Style Models: 800, 802, 808N, 809N The barb at the bottom of the manometer will friction fit onto the tubing of most commercially available two tube cuff and bladder systems. WARNING: The pocket style manometer is designed for use with TWO tube systems where one tube connects to the manometer and the other connects to the inflation source (bulb and valve). 3

0197 Lifetime Certified mmhg Palm Style Model: 804N Assemble the supplied luer slip connector onto the free end of the cuff tubing by inserting the barbed end of connector into tubing. Connector will friction fit onto the tubing of most commercially available ONE tube cuff and bladder systems. Insert luer slip connector into the port at the top of the palm gauge and turn slightly to engage. 160 140 180 120 200 100 220 80 60 40 20 240 260 280 300 WARNING: The palm style manometer is designed for use with ONE tube systems. WARNING: To avoid damage to the instrument, do not force connector into port. Clock Style Model: 805 The barb at the bottom of the manometer will friction fit onto most commercially available coiled tubing. WARNING: The clock style manometer is designed for use with TWO tube systems where one tube connects to the coiled tubing attached to the manometer, and the other connects to the inflation source (bulb and valve) 140 160 180 120 200 100 220 240 80 260 60 40 280 20 300 SPHYGMOMANOMETER Lifetime Certified 0197 mmhg CAUTION: For all blood pressure systems that can be wall mounted, ensure that the unit is securely mounted prior to use to avoid damage to the instrument and potential patient injury. Maintenance: The manometer may be cleaned with a soft cloth but should not be dismantled under any circumstances. Gauge accuracy can be checked visually; simply be certain the needle rests within the printed oval when the unit is fully deflated. Should the indicator needle of the manometer rest outside of this calibration mark, then the manometer must be re-calibrated to within ±3 mmhg when compared to a reference device that has been certified to national or international measurement standards. No manometers that have their indicator needle resting outside of this mark are acceptable for use (Figure 1). The manufacturer recommends a calibration check every 2 years. Standards: ANSI/AAMI/ISO 81060-1:2007 EN / ISO 81060-1:2012 NOTE: Store gauge with valve in full exhaust position. (Figure 1) 4

Convertible Bladder p/n 815-A 100 % LEAK TESTED Convertible Bladder p/n 815-A 100 % LEAK TESTED Convertible Bladder p/n 815-A 100 % LEAK TESTED Bladder Model: 815 Series Intended Use: ADCUFF bladders are noninvasive inflation bags designed to be used with ADC and compatible blood pressure cuffs. They are intended for use with manual and automated noninvasive blood pressure measurement devices. Assembling the Convertible Bladder Build a 1 or 2 tube bladder connection depending upon your requirements. One simple connection is all that is necessary: Pocket or Clock Aneroids or Mercurial Sphygs require a 2 tube bladder Palm or Multicuff Aneroids require a 1 tube bladder. What is included: (1) Bladder Shell with 1 tube attached and an open barb (1) Cap: To close off open barb for 1 tube bladder use (1) Tube: To connect to open barb for 2 tube bladder use Cap Bladder Shell Adult Size Tube Converitble Bladder Connections (1 or 2 tube) 1 tube - Securely attach enclosed Cap to exposed barb on bladder shell. 2 tube - Securely attach enclosed second tube to exposed barb on bladder shell. 1 Tube Connection 2 Tube Connection Adult Size Adult Size NOTE: Rubbing alcohol or soapy water can facilitate connections. Make sure connection is secure. WARNING: Connections are not designed to be converted back and forth on a regular basis. 5

TM TM (Figure 2) Inserting Bladder into Cuff To insert the bladder into the cuff; 1. Roll bladder into a tube starting from long edge opposite tubing (Figure 2). 2. Insert left edge of bladder into cuff opening (at bottom edge of cuff) until it is completely inside. Shake cuff until bladder fully unravels. (Figure 3). (Figure 3) Index Line 3. Thread tubes through smaller openings (from inside of cuff out) and tuck flap in to secure bladder. To make sure that bladder fills compartment, inflate before initial use. (Figure 4). Index Line (Figure 4) Cuff Models: 845 Series Intended Use: ADC blood pressure cuffs are noninvasive blood pressure cuffs that are intended for use with manual and automated noninvasive blood pressure measurement devices. Contraindications: Aneroid sphygmomanometers are contraindicated for neonate use. Do not use with neonatal cuffs or neonate patients. Review the size chart for proper age and limb range usage (Right). Cuff Size Chart Size Limb Range Inches CM Infant 7 3.5 to 5.5 9 to 14 Child 9 5.1 to 7.6 13 to 19.5 Small Adult 10 7.4 to 10.6 19 to 27 Adult 9 to 15.7 23 to 40 Large Adult 12 13.3 to 19.6 34 to 50 Thigh 13 15.7 to 25.9 40 to 66 Bariatric 12 17.32 to 25.9 44 to 66 6

TM TM Size Guide TM Marking System: ADC s Size Guide marking system assures use of correct cuff size and proper cuff alignment. Printed Index and Range markings and applicable limb range (in cm) allow easy identification of the correct cuff size. An artery mark printed on both sides indicates bladder midpoint for correct cuff positioning. A convenient nylon hang tag permits flexible use with either pocket aneroids or mercury manometers. Hook and loop adhesive surface provides a snug, infinitely variable fit and is designed to withstand a minimum of 30,000 open/close cycles. Gauge Hang Tab Hook & Loop Closure Adhesive Reusable BP Cuff 13 T 12 X A 10 9 SA C 7 I Index Line 23-40 cm Adult - 23-40 cm Size Icons Artery Mark Bladder Flap Index Line Artery Mark Range Lines Applying Cuff: Place the cuff over the bare upper arm with the artery mark positioned directly over the brachial artery. The bottom edge of the cuff should be positioned approximately (1 ) one inch (2-3cm) above the antecubital fold. Wrap the end of the cuff NOT containing the bladder around arm snugly and smoothly and engage adhesive strips. To verify a correct fit, check that the INDEX line falls between the two RANGE lines (Figure 5). Left Arm (Figure 5) Tube 7

Maintenance: Clean and disinfect as required Cleaning Use one or more of the following methods and allow to air dry: Wipe with mild detergent and water solution (1:9 solution). Rinse. Wipe with Enzol per manufacturer s instructions. Rinse. Wipe with.5% bleach and water solution. Rinse. Wipe with 70% isopropyl alcohol. Launder with mild detergent in warm water, normal wash cycle. Remove bladder first. Cuff is compatible with 5 wash cycles. Low Level Disinfection Prepare Enzol enzymatic detergent according to the manufacturer s instructions. Spray detergent solution liberally onto cuff and use a sterile brush to agitate the detergent solution over entire cuff surface for five minutes. Rinse continuously with distilled water for five minutes. To disinfect, first follow the cleaning steps above, then spray cuff with 10% bleach solution until saturated, agitate with a sterile brush over entire cuff surface for five minutes. Rinse continuously with distilled water for five minutes. Wipe off excess water with sterile cloth and allow cuff to air dry. Bulb and Valve Assembly - Model 872N Intended Use ADC blood pressure bulb and valves allow for controlled inflation and deflation of the blood pressure cuff. They are intended for use with manual noninvasive blood pressure measurement devices. To Operate: Close the valve by fully rotating thumbscrew clockwise. To open, rotate counterclockwise. Deflation should be maintained at a consistent rate of 2-3mmHg/second throughout measurement for best results (in accordance with recommendations set forth by the AHA). 8

Maintenance: Your bulb and valve assembly is equipped with an end valve that allows the intake of air into your blood pressure device. It is recommended that the end valve be checked for debris and cleaned on a regular basis to ensure that dust and other debris does not reduce airflow. NOTE: Some end valves are equipped with a filter screen to help prevent the ingress of dust from the environment. Manometer Quality Control A Serial number and Lot number are automatically assigned to every aneroid during manufacturing, ensuring every item is "controlled". This Serial Number can be located on the faceplate of each aneroid (Figure 6). The Lot number is located on the outside label of all accessory packaging (Figure 7). Serial Number Lot Number (Figure 6) LOT: 0000 LOT 0 00000 000 (Figure 7) Disposal When your sphygmomanometer or any of its parts have reached its end of life, please be sure to dispose of it in accordance with all regional and national environmental regulations. Devices that have become contaminated should be disposed of in accordance with all local ordinances and regulations. 9

Warranty American Diagnostic Corporation s (ADC ) warranty service extends to the original retail purchaser only and commences from the date of delivery. ADC warrants its products against defects in materials and workmanship under normal use and service as follows: Your Manometer is warranted for 10 years, 20 years, or Life depending upon the model. Refer to label or end panel for specific warranty denotation. The manometer is warranted to remain accurate to +/-3mmHg (or the prevailing standard) over its full range when compared to a reference standard or life. Adcuff TM inflation system components (cuff, bladder, tubing, bulb, valves, connectors) are warranted for three years. Specialty cuffs and bladders are warranted for 2 years. What is Covered: Replacement of parts, and labor. What is Not Covered: Transportation charges to and from ADC. Damages caused by abuse, misuse, accident, or negligence. Incidental, special, or consequential damages. Some states do not allow the exclusion or limitation of incidental, special, or consequential damages, so this limitation may not apply to you. To Obtain Warranty Service: Send item(s) postage paid to ADC, Attn: Repair Dept., 55 Commerce Dr., Hauppauge, NY 788. Please include your name and address, phone no., proof of purchase, and a brief note explaining the problem. Implied Warranty: Any implied warranty shall be limited in duration to the terms of this warranty and in no case beyond the original selling price (except where prohibited by law). This warranty gives you specific legal rights and you may have other rights which vary from state to state. 10

To register your product visit us at www.adctoday.com/register FOR QUESTIONS, COMMENTS, OR SUGGESTIONS CALL TOLL FREE: 1-800-ADC-2670 OR VISIT www.adctoday.com/feedback This manual is available online in a variety of languages, follow the links for language options. www.adctoday.com/care IB p/n 9355N-00 rev 4 ADC 55 Commerce Drive Hauppauge, NY 788 U.S.A. ADC (UK) Ltd. Unit 6, PO14 1TH United Kingdom Inspected & Packaged in the U.S.A. tel: 631-273-9600 toll free: 1-800-232-2670 fax: 631-273-9659 www.adctoday.com info@adctoday.com Printed in the U.S.A.