Diffused Aeration Systems. Installation Operating Maintenance Guidelines

Similar documents
Diffused Aeration Systems Installation Operating Maintenance Guidelines

Diffused Aeration Systems

Diffused Aeration Systems

Thank you for your purchase! Safety Warnings. Operation. Summer Time Start Up

Owner's Manual THAWLINE BUBBLER DE-ICING SYSTEM

Installation and Operating Instructions

Vianti Falls Fire Burner Kit (HBF16) & Propane Adapter Kit (HBF16AK) (These instructions are intended for use with a 20 lb.

Vessel Installation and Operating Manual

Installation and Operating Manual

Aeration of Dugouts or Ponds with Compressed Air

Model No Product Name Handpiece Only Complete System

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

RG3100 and RG3100Ice Regulator System

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

Aeration of Dugouts or Ponds with Compressed Air

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Model PSI Compressor with 3-Gallon Air Tank 12VDC

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

444C DUAL PERFORMANCE VALUE PACK

OWNER S MANUAL. Page: 1 of 8

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

CF-SERIES HIGH FLOW REGULATORS

VAC-U DRIVE Swinging float arm for Acrobat like agility 36 Fin disk with DEEP VEE Scoop

Cocoa Patio Pond with Lit Spillway

High Performance Oilless Commercial Refrigerant Recovery Unit. User Manual

200 PSI COMPRESSORS - MODEL NUMBERS

VANDAL SUP OWNER S MANUAL

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

Pure Water Power Purification System 4-Stage RODI Operations Manual

100C Air Compressor Kit

AIR INLINE METAL SHEAR

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

10 DRIP NOZZLE WATERING DRIP KIT Model / Model 46095

J Air and Water Kit Instructions Part# 02584

Booster Pump PB4-60 Replacement Kits

Marschalk Model # 94000

2 GAL AIR COMPRESSOR OPERATOR S MANUAL 1/3HP/2-GALLON IMPORTANT: READ THIS OPERATOR S MANUAL BEFORE USING

Aqua Tower Slide Owner s Manual

MODEL NUMBER: AS18-2 USER GUIDE

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,

IMPORTANT SAFETY INSTRUCTIONS

ULTRA HIGH PRESSURE PAINT GRATE CLEANER FCT-JS OPERATION AND MAINTENANCE MANUAL

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

accidents which arise due to non-observance of these instructions and the safety information herein.

G7S Hand Pump Owner s Manual

INSTRUCTION MANUAL AIR-POWERED DUAL-ACTION SANDER

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

High Performance Oilless Commercial Refrigerant Recovery Unit. User Manual Rev. 4 November 2010

PC1131 Electric Air Compressor

400C & 450C DUAL PERFORMANCE VALUE PACKS

OPERATOR S MANUAL 1.5 HP/6-GALLON 6 GAL AIR COMPRESSOR IMPORTANT: READ OPERATOR S MANUAL BEFORE USING. Toll Free Helpline:

OPERATING INSTRUCTIONS

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

Siting and Installation Manual

Please Do Not Return This Product To The Store!

2 Gallon Air Compressor

Model ASSEMBLY and OPERATING INSTRUCTIONS

3" UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC.

Checklist for care of Respirators

Lubricated TC Models

easycomposites SETUP & DAILY USE INSTRUCTIONS NEVER SWITCH OFF YOUR PUMP WITHOUT FIRST CLOSING THE VALVE TO THE CHAMBER

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

Budget Range Operators Handbook

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

20 GAL OIL FREE AIR COMPRESSOR

isup MANUAL THANK YOU FOR PURCHASING A KAHUNA isup, WE HOPE YOU HAVE MANY YEARS OF PADDLING ENJOYMENT.

Installation of Your SprayMaster System

MOOWII MANUAL. Using a kite is dangerous and can cause severe injuries. Before use, carefully read this manual.

Freedom8 ShoeBox Compressor Manual

D Series Air and Water Kit Part# 02550

INSTRUCTION MANUAL AIR-POWERED STAPLER

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

MAGNA-CHEM AUTOMATIC CHLORINATOR - MODEL: CSA-2P MAGNA ORP Chlorine Pump

HAS2400 Hepa Air Scrubber

KOBOLD KSM FLOWMETER. User Instructions

UltRo Dual Flow Reverse Osmosis Water System

TactAir PCP Fill Kit/Adapter. Operation Manual

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

INTENDED USE TECHNICAL SPECIFICATIONS

Hygienic Bubble Trap Installation and Operations Manual

Inflatable Stand Up Paddle Board Manual

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

Pressure Relief Valve Instruction Manual

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

CSA Sample Draw Aspirator Adapter Operator s Manual

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

ULTRA-LIGHT DUTY ONBOARD AIR SYSTEM

Composite Pistol-Type Air Needle Scaler OWNER S MANUAL

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

AIR-POWERED MINI PALM-GRIP NAILER

Transcription:

Diffused Aeration Systems Installation Operating Maintenance Guidelines

Thank you for your purchase! Your aeration system will be a great benefit to the aquatic ecosystem in which you are placing it. The following are some important guidelines regarding the installation and operation of your system. Installation... The air diffuser should not be placed in the deepest part of the pond. Try to locate the diffuser at approximately 2/3 to 3/4 of the deepest point (a 15' deep pond would have the diffuser at approximately 10' to 12' deep). This allows the deepest water to remain cool in the Summer and stay warm in the Winter. If you purchased your aeration system without weighted tubing, you will need to supply small weights such as chimney bricks, pipe or rerod. Strap the weights securely around the tubing to bring it to the bottom. If your pond freezes during the winter, be sure the tubing is buried leading into the pond. If not, the ice can form around the tubing, kinking it or possibly shearing it off. Operation... All of our compressors are designed for continuous operation. It is not uncommon for these compressors to run 24 hours per day for four to five years. The only maintenance required is replacement of vanes or diaphragms when needed. All compressors have oilless motors. Never oil or lubricate the motors. The surface of the compressor will be hot during operation. This is normal be careful not to touch the compressor while it is running. In addition to adding oxygen to your pond, one of the main benefits to an aeration system is the circulation it creates. It takes hours for the maximum circulation to be achieved, therefore we recommend running these systems continuously so that maximum circulation is sustained. Systems that operate a few hours each day will just get the circulation going and then it is time to shut off. If you are installing this system at a time when your pond is already stratified (warm on surface, cold on bottom), you should be careful when first starting the aeration system. If the stagnant water on the pond bottom is stirred up too fast, a temporary increase in oxygen demand will occur and, in rare cases, a fish kill could result. If your pond is severely stratified, you should only run your system one to two hours the first day. Each day after that, increase the run time by one to two hours during the first week, run continuously after that. This will slowly mix the bottom water without a sudden depletion of oxygen. Please contact us prior to start-up if you have questions. Maintenance... It is critical that the air compressors be protected from the weather. You will need to provide a shelter for your compressor to protect it from rain, snow and other harsh elements. Be sure your shelter has adequate ventilation. Also be sure the compressor does not sit directly on the ground, as the vibration from the motor will cause dust and dirt particles to be pulled into the motor and cause premature failure. 1/20 HP Aeration System The PA10 aerator features a 1/20th horse power continuous duty air compressor, 50' of tubing and a pond diffuser. Once the air diffuser is assembled and the tubing is attached, you are ready to install the diffuser into the pond. Always unroll the tubing completely before installing the diffuser. The diffuser can be lowered into your pond with a rope. Often a float, such as a duck decoy or a milk jug, will be used so retrieval of the diffuser is possible. 2

were received. If a shortage occurs, please notify us immediately. 2. Screw the two airstones into the PVC manifold. Do not overtighten! Hand tighten only! 3. Slide one end of the tubing onto the barbed adapter coming out of the PVC manifold. Clamp this connection using the clamp provided. 4. Position the PVC manifold and airstones onto the white plastic underlay. Use the plastic straps provided to attach the manifold to the underlay. 5. Attach the other end of the tubing to the compressor and tighten. After one or two years of operation, you will possibly notice a sudden drop in air bubbles. This is a sure sign that the diaphram has cracked and needs replacing. Repair kit DC22RK has all the items necessary to rebuild your compressor. Be sure to clean the inlet air filter on your compressor regularly. Wash dirty air filters in soapy water. Replacement filters are available. PA10 Packing List: Air Compressor w/filter 1 PVC Manifold w/check Valve 1 Air Diffusers 2 Tie Straps 3 Tubing Clamps 2 50' Roll Tubing 1 12" x 21" Underlay 1 1/8 HP Aeration System The PA12 aerator features a 1/8 horse power continuous duty air compressor, 50' of tubing and a pond diffuser. Once the air diffuser is assembled and the tubing is attached, you are ready to install the diffuser. Always unroll the tubing completely before installing the diffuser. The diffuser can be lowered into your pond with a rope. Often a float, such as a duck decoy or a milk jug, will be used so retrieval of the diffuser is possible. were received. If a shortage occurs, please notify us immediately. 2. Screw the two airstones into the PVC manifold. Do not overtighten! Hand tighten only! 3. Slide one end of the tubing onto the barbed adapter coming out of the PVC manifold. Clamp this connection using the clamp provided. 4. Position the PVC manifold and airstones onto the white plastic underlay. Use the plastic straps provided to attach the manifold to the underlay. 5. Attach the other end of the tubing to the compressor and tighten. After one or two years of operation, you will possibly notice a sudden drop in air 3

bubbles. This is a sure sign that the diaphram has cracked and needs replacing. Repair kit DC12RK has all the items necessary to rebuild your compressor. Be sure to clean the inlet air filter on your compressor regularly. Wash dirty air filters in soapy water. Replacement filters are available. PA12 Packing List: Air Compressor w/filter 1 PVC Manifold w/check Valve 1 Air Diffusers 2 Tie Straps 3 Tubing Clamps 2 50' Roll Tubing 1 12" x 21" Underlay 1 1/4 HP RP Aeration System The PA33 aerator features a 1/4 horse power continuous duty air compressor, 100' of tubing and a membrane diffuser. Once the air diffuser is assembled and the tubing is attached, you are ready to install the diffuser into the pond. Always unroll the tubing completely before installing the diffuser. The diffuser can be lowered into your pond with a rope. Often a float, such as a duck decoy or a milk jug, will be used so retrieval of the diffuser is possible. were received. If a shortage occurs, please notify us immediately. 2. Screw the round rubber membrane diffuser into the PVC base. Fill base with sand or small stone. 3. Slide one end of the tubing onto the barbed adapter on the PVC base and secure with a clamp (provided). 4. Attach the 2' piece of flex pipe into the outlet side of the compressor. 5. Unroll the entire roll of pipe. It is recommended that the pond diffuser be installed at this point. This will allow you to trim any unused pipe before attaching to the pump. Once installed and trimmed, attach the other end of the tubing to the flexible hose on the compressor. The flexible membrane diffuser is buoyant (even if weighted hose is used) unless the base is filled with sand or gravel. Be sure to fill base at least 2/3 full. After one or two years of operation, you will possibly notice a sudden drop in air bubbles. This is a sign that the piston rings have cracked and need replacing. Repair kit RP74RK has all the items necessary to rebuild your compressor. 4

Be sure to clean the inlet air filter on your compressor regularly. Wash dirty air filters in soapy water. Replacement filters are available. PA33 Packing List: 2" Flex Hose (weighted kits only) 1 Membrane Air Diffuser w/base 1 Tubing Clamps 2 100' Roll Tubing 1 PA50W & PA60W Aeration System These aeration systems come with a continuous duty compressor, 200 feet of hose and two air diffusers. Once the air diffuser is assembled and the tubing is attached, you are ready to install the diffuser. Always unroll the tubing completely before installing the diffuser. The diffuser can be lowered into your pond with a rope. Often a float, such as a duck decoy or a milk jug, will be used so retrieval of the diffuser is possible. were received. If a shortage occurs, please notify us immediately. 2. Screw the round rubber membrane diffuser into the PVC base. Fill base with sand or small stone. 3. Slide one end of the tubing onto the barbed adapter on the PVC base and secure with a clamp (provided). 4. Attach the 2' piece of flex pipe into the outlet side of the compressor. 5. Unroll the entire roll of pipe. It is recommended that the pond diffuser be installed at this point. This will allow you to trim any unused pipe before attaching to the pump. Once installed and trimmed, attach the other end of the tubing to the flexible hose on the compressor. 6. Connect the valved outlet assembly to the compressor. 7. Connect the tubing to the flex hose on the compressor. Once the compressor is running, you may have to adjust the valves to equal the air flow to each diffuser. This corrects the difference in air flow caused by a difference in operating depth and/or tubing lengths. The PA50 and PA60 aeration systems are identical except for the compressor. The PA60 compressor has a higher pressure rating for deeper water operation. All other items and assembly are the same for these two kits. After one or two years of operation, you will possibly notice a sudden drop in air bubbles. This is a sign the compressor needs new vanes. A rebuild kit is available to restore like-new performance. Be sure to keep the air filter clean. Wash dirty air filters in soapy water. Replacement filters are available. 5

PA50 and PA60 Packing List: Air Compressor w/filter 1 Valve Assembly 1 Membrane Diffusers 2 Tubing Clamps 4 200' Roll Tubing 1 PA75 and PA100 Aeration Systems... The PA75 system uses a 3/4 horse power high-volume compressor with 800 feet of tubing and four air diffusers. The maximum operating depth is 18 feet. The PA100 system uses a 1 horse power compressor with 1000' of tubing and five air diffusers, maximum operating depth is 18'. were received. If a shortage occurs, please notify us immediately. 2. Screw the round rubber membrane diffuser into the PVC base. Fill base with sand or small stone. 3. Slide one end of the tubing onto the barbed adapter on the PVC base and secure with a clamp (provided). 4. Attach the 2' piece of flex pipe into the outlet side of the compressor. 5. Unroll the entire roll of pipe. It is recommended that the pond diffuser be installed at this point. This will allow you to trim any unused pipe before attaching to the pump. Once installed and trimmed, attach the other end of the tubing to the flexible hose on the compressor. 6. Connect the valved outlet assembly to the compressor. 7. Connect the tubing to the flex hose on the compressor. Once the compressor is running, you may have to adjust the valves to equal the air flow to each diffuser. This corrects the difference in air flow caused by a difference in operating depth and/or tubing lengths. The PA100 system installs the same as PA75, it simply has five airlines instead of four. After one or two years of operation, you will possibly notice a sudden drop in air bubbles. This is a sign the compressor needs new vanes. A rebuild kit is available (Part #RV75V for 3/4 HP compressor, RV100V for 1 HP) to restore like-new performance. Be sure to keep the air filter clean. Filters can be washed in soapy water. Replacement filters are available. 6

PA75 and PA100 Packing List: Description PA75 Qty. PA100 Qty. Packed Air Compressor w/filter 1 1 Valve Assembly 1 1 Membrane Diffusers 4 5 Tubing Clamps 8 10 200' Roll Tubing 4 5 Windmill Aeration System... The windmill pond aerator is an excellent alternative to electric pond aerators. The windmill has a complete set of instructions included with it. Please follow these instructions to assemble the windmill head and tower. We supply the air hose and air diffuser for this windmill kit. Note: A check valve is included with the windmill to go in the airline underwater by the air diffuser. Our air diffuser includes a built-in check valve so you will not need the one included with the windmill. When you get to page 5 in the instruction book, please follow these instructions for the diffuser installation: Fill base of air diffuser with sand or gravel. Screw membrane diffuser into top of base. Attach end of tubing to outlet and clamp. Unroll the tubing completely before attempting to install the diffuser assembly in your pond. Tubing needs to be weighted to sink. Usually a three to five pound weight every six to eight feet is adequate. Weights can be landscape bricks, rerod, etc., and should be strapped tightly to the tubing with electric ties. Omit this step if you are using self-weighted tubing. A 20' piece of black plastic hose is included with your windmill. This tubing connects to the outlet on the compressor at the top of the windmill and runs down the tower to the ground. A connector is included to connect to the 100' roll of tubing at this point. After installing the manifold in the pond, connect the other end of the vinyl tubing to the end of the black tube coming off the windmill. 7

Windmill Packing List - # of Boxes Varies: Membrane Air Diffuser w/base 1 Tubing Clamps 1 100' Roll 3 /8" Vinyl Tubing 1 12" x 21" Underlay 1 Warranty: This product is warrantied against any mechanical or material defects for a period of one year from the date of purchase. Windmill aeration system only, is warrantied for five years from date of purchase. Warranty only covers properly installed and maintained units. The warranty does not cover normal wear and tear, nor any deterioration suffered through overloading, improper use, negligence or accident. Similarly, any modification made by the purchaser to the product will cause the warranty to be null and void. All returned items will be inspected to determine cause of failure before warranty is approved. Warranty does not cover any cost associated with the installation or removal of the product subject to warranty claim. An RA number must be obtained by calling EasyPro Pond Products at 800-448-3873. It is your responsibility to pay the return shipping charges. Be sure to include the RA number, original receipt (in the form of an invoice or sales receipt), name, return address and phone number inside of the package. No warranty claims will be honored without the original receipt. Ensure the product is properly packaged and insured for the replacement value. Damage due to improper packaging is the responsibility of the sender. The manufacturer or supplier shall not be held liable for any damages caused by defective components or materials of this product; or for loss incurred because of the interruption of service; or any consequential/incidental damages and expenses arising from the production, sale, use or misuse of this product. The manufacturer or supplier shall not be held liable for any loss of fish, plants or any other livestock as a result of any failure or defect of this product.