DK46 - DK800 Supplementary instructions

Similar documents
VA FLOWMETERS Supplementary Instructions

Supplementary Installation and Operating Instructions. Variable Area Flow Meters SGK-1 Ex SGK-2 Ex SGK-3 Ex. Category: II 2G Ex IIC II 3G Ex IIC

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

DK48 - DK800. Quick Start. Variable area flowmeter

VA40 - VA45 Technical Datasheet

Technical Data. Dimensions

OPTIBAR P 1010 C Technical Datasheet

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Technical Data. General specifications. Rated operating distance s n 2 mm

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

GA24. GA24 Handbook. Variable-area flowmeter. KROHNE 02/ MA GA24 R01 en

GA24 Technical Datasheet

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

Technical Data. Dimensions

Technical Data. Dimensions

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

DK 37 M8. All-metal miniature flowmeters. For hazardous-duty devices, please refer to Supplementary Installation and Operating Instructions:

VG5 Supplementary instructions

Level transmitter LT 100

Inductive slot sensor

Liquid level instruments BM 24 /BM 51

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Liquid level switch BM 34

Magnetic level switch type MR783 Instruction Manual

Technical Data. Dimensions

Technical Data. Dimensions

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

Technical Data. Dimensions

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

H250 M9 Supplementary instructions

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

Pressure Switches Application Guideline

RTD temperature probes

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

Pressure switch KP-E. Data sheet

Installation and Operating Instructions Bypass Flow Meter DST

Pressure Measurement Single-range transmitters for general applications

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

D10S/D20S Wall/Post Mount Inflator Quick Start Manual

II 2G EEx ia IIC T6. Ignition protection class

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Pressure control, differental pressure control and thermostat Type RT

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

Bourdon tube pressure gauge for diaphragm seals

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Brass Check Valve RDL

deltaflowc deltaflowc Venturi or Probe

Certificate of Compliance

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

Operating Instructions

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85

Pressure switch, Differential pressure switch and Thermostat RT-E

SITRANS P measuring instruments for pressure

Monitoring device NTS 30

Gas density monitor With integrated transmitter Model GDM-100-TI

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL M2

Manual Power relay SR853

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

Operating instructions for variable area flow meter with needle valve. Model: UVR/UTR

Operating Instructions

Mechanical pressure switches

Further technical information is available on

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL PRV44

Pressure switch with bourdon tube

Temperature gauge Installation Guide

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

3000 Series OPTIMASS Mass Flowmeter. Stainless Steel Hastelloy

Intrinsically safe solenoid valves on/off controls - ATEX certification

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

6-5 Maintenance Manual

sitrans p Operating Instructions (de/en) Edition 03/2004

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

Type BBS-03, BBS-05, BBS-06, BBS-25

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Instruction Manual Contact Pressure Vacuum Gauge

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Transcription:

DK46 - DK800 Supplementary instructions Variable area flowmeter Device category II2G with electrical internals Additional Ex manual KROHNE

CONTENTS DK46 - DK800 1 Safety instructions 3 1.1 General... 3 1.2 EC conformity... 3 1.3 Security information... 3 2 Device description 4 2.1 Device description... 4 2.2 Description code... 4 2.3 Marking... 5 2.4 Flammable products... 6 2.5 Equipment category...6 2.6 Types of protection... 6 2.7 Ambient temperature / temperature classes... 7 3 Installation 9 3.1 Installation... 9 4 Electrical connections 10 4.1 Electrical connection...10 4.2 Terminal assignment... 10 4.3 Connecting cable... 11 4.4 Earthing and equipotential bonding... 11 5 Operation 12 5.1 Start-up... 12 5.2 Operation... 12 5.3 Static electricity... 13 6 Service 14 6.1 Maintenance... 14 6.2 Dismantling... 14 2

DK46 - DK800 SAFETY INSTRUCTIONS 1 1.1 General These supplementary Ex instructions apply for explosion-protected designs of the variable area flowmeters DK.../../../..-Ex for the category II2G. They supplement the installation and operating instructions for non-explosion-protected designs. The information in these instructions contains only the data concerning the explosion protection of category 2. The technical details in the installation and operating instructions for the non-explosionprotected designs apply unchanged in as far as they are not excluded or replaced by these instructions. 1.2 EC conformity The manufacturer declares with the EC Declaration of Conformity on his own responsibility conformity with the protection goals of Directive 94/9/EC for use in hazardous areas with gas. The EC Type Examination Certificate of the Physikalisch Technische Bundesanstalt (PTB) forms the basis of the EC Declaration of Conformity: PTB 05 ATEX 2021 X If required the EC Type Test Certificate can be downloaded under. 1.3 Security information Assembly, installation, start-up and maintenance may only be performed by personnel trained in explosion protection! CAUTION! The operator respectively his agent is responsible to follow further standards, directives or laws if required due to operating conditions or place of installation. This applies particularly for the use of easy detachable process connections such as SMS or Clamp when measuring flammable mediums. 3

2 DEVICE DESCRIPTION DK46 - DK800 2.1 Device description Variable area flowmeters measure the volume flow of flammable and non-flammable gases and liquids. Up to two separately adjustable electrical limit switches can be mounted to the on-site display. 2.2 Description code The safety description code * consists of the following elements: 1 R - with integrated inlet pressure regulator (DKR46 only) 2 Device type: 46 - Overall length of measuring cone 65 mm 47 - Overall length of measuring cone 150 mm 48 - Overall length of measuring cone 300 mm 800 - Overall length of measuring cone 100 mm 3 Material for top and bottom fittings N - brass R - stainless steel PV - PVDF 4 Differential pressure regulators RE - inlet pressure regulator RA - outlet pressure regulator 5 K1 - one limit switch / K2 - two limit switches * positions which are not needed are omitted (no blank positions) 4

DK46 - DK800 DEVICE DESCRIPTION 2 2.3 Marking The marking for the entire device is provided on the indicator part with the marking plate shown below. 1 Device type 2 Manufacturer 3 Notified ATEX body 4 Sizing data: temperature & pressure 5 PED data 6 Ex data 7 Electrical connection data 8 KROHNE website 9 Type of limit switch Additional markings on the measuring device SN - serial number SO - sales order / item Tag-No - Measuring point identifier MD - manufacturing date PA - KROHNE order Vx - product configurator code AC - article code 5

2 DEVICE DESCRIPTION DK46 - DK800 2.4 Flammable products Atmospheric conditions An explosive atmosphere is defined as a mixture of air and flammable gases, vapours, mists or dusts under atmospheric conditions with the values T atm = -20 C...+60 C / -4 F...140 F and P atm = 0,8...1,1bar. Outside of this range, no key data are available as to ignition behaviour for most mixtures. Operating conditions Variable area flowmeters operate outside of atmospheric conditions, which means that explosion protection according to Directive 94/9/EC (ATEX) regardless of the zone assignment is fundamentally not applicable due to the lack of key safety data for the interior of the measuring unit. CAUTION! Operation with flammable products is only permissible if no explosive fuel/air mixture is formed on the interior of the flowmeter under operating conditions. The user is responsible for the safe operation of the flowmeter with regard to the temperatures and pressures of the products used. In case of operation with flammable products the measuring units must be included in the periodic pressure tests of the system. 2.5 Equipment category The flowmeters are designed in Category II 2G according to EN 60079-0 and EN 60079-11 for use in Zone 1. 2.6 Types of protection The circuits of the limit switches (ring sensors) are designed in Intrinsic Safety type of protection of Category ia. They can also be operated in Category ib. 6

DK46 - DK800 DEVICE DESCRIPTION 2 2.7 Ambient temperature / temperature classes Because of the influence of the temperature of the product, no permanent temperature class is assigned to variable area flowmeters. In fact, the temperature class of a device is a function of the temperature of both the product and the environment. There is no distinction between devices with one or two contacts. The classification is outlined in the following tables. The tables take into account the following parameters: Ambient temperature T amb. Product temperature T m Installed equipment Supply type (maximum value for Pi) INFORMATION! The maximum permissible product temperatures listed in the tables are valid under the following conditions: The measuring device is installed and operated in accordance with the installation instructions in the installation and operating manual. It must be ensured that the flowmeter is not heated by the effects of additional heat radiation (sunshine, neighbouring system components) and thus operated above the permissible ambient temperature range. Insulation must be limited to the piping. Unobstructed ventilation of the indicator part must be ensured. 7

2 DEVICE DESCRIPTION DK46 - DK800 Temperature table in C Type of limit switch Maximum permissible ambient / medium temperature in C Supply Temperature table in F Type 1 Type 2 Type 3 Temperature class T6 T5 T4...T1 T6 T5 T4...T1 T6 T5 T4...T1 RC10-14.-N0... 65 65 65 65 65 65 50 65 65 RC15-14.-N0... RC10-14.-N3... 70 75 75 65 75 75 50 65 75 RC15-14.-N3... 70 70 70 65 70 70 50 65 70 I7R2010-N*** 70 80 80 65 80 80 50 65 80 I7R2015-N*** I7R2010-NL*** I7R2015-NL*** 70 80 80 70 80 80 65 80 80 The maximum lower ambient temperature is -20 C Type of limit switch Maximum permissible ambient / medium temperature in F Supply Type 1 Type 2 Type 3 Temperature class T6 T5 T4...T1 T6 T5 T4...T1 T6 T5 T4...T1 RC10-14.-N0... 149 149 149 149 149 149 122 149 149 RC15-14.-N0... RC10-14.-N3... 158 167 167 149 167 167 122 149 167 RC15-14.-N3... 158 158 158 149 158 158 122 149 158 I7R2010-N*** 158 176 176 149 176 176 122 149 176 I7R2015-N*** I7R2010-NL*** I7R2015-NL*** 158 176 176 158 176 176 149 176 176 The maximum lower ambient temperature is -4 F These values may be limited by the data given in the Installation and Operating Instructions. The maximum values given in the Installation and Operating Instructions must be taken into consideration. 8

DK46 - DK800 INSTALLATION 3 3.1 Installation Installation and setup must be carried out according to the applicable installation installation standards (e.g. EN 60079-14) by qualified personnel trained in explosion protection. The information given in the Installation and Operation Instructions and the Supplementary Installation and Operation Instructions must always be observed. Variable area flowmeters must be installed in such a way that There is no danger from mechanical impact effects. There are no external forces affecting the indicator part. The device is accessible for any visual inspections that are necessary, and can be viewed from all sides. The nameplate is clearly visible. It can be operated from a location with secure footing. CAUTION! The manufacturer is not liable for any damage resulting from improper use or use other than the intended purpose. This applies in particular to hazards due to insufficient corrosion resistance and suitability of the materials in contact with product. 9

4 ELECTRICAL CONNECTIONS DK46 - DK800 4.1 Electrical connection The built-in intrinsically safe NAMUR limit switches in the variable area flowmeter DK.../../../.. may only be connected to isolation switching amplifiers with separated intrinsically safe circuits to DIN 19234 with the following max. values: Maximum values of the power supply units Supply P i [mw] U i [V] I i [ma] Type 1 34 16 25 Type 2 64 16 25 Type 3 169 16 52 When connecting to intrinsically safe circuits, take into consideration the following maximum values per circuit as a function of the limit switch (see plate on terminal box) for the energy stores. Type of limit switch C i [nf] L i [µh] RC10-14.-N0.../RC15-14.-N0... I7R2010-N***/I7R2015-N*** 210 100 RC10-14.-N3... I7R2010-NL*** 150 120 RC15-14.-N3... I7R2015-NL*** 150 70 4.2 Terminal assignment Connect the built-in intrinsically safe components to terminals + / - in accordance with the following illustration and table. Connect one limit switch to each terminal block. Take note of the polarity indicated. Connection of limit switch - 2 wire NAMUR 1 Lower limit switch to terminal 1 2 Upper limit switch to terminal 2 The connection box includes an EMC filter unit. For devices with just one limit switch, the connection is on terminal 1. 10

DK46 - DK800 ELECTRICAL CONNECTIONS 4 4.3 Connecting cable Select the connecting cables for the intrinsically safe circuits according to the valid wiring standard (e.g. EN 60079-14). Make sure that no residual current can form between different intrinsically safe circuits of the variable area flowmeter. Lay cables so as to ensure that there is sufficient distance between surfaces of the measuring unit and the connecting cable. 4.4 Earthing and equipotential bonding If the device is not adequately grounded electrostatically by way of the process piping, make an additional ground connection 1 by way of the ground connection. The location of the ground connection on the back rail is shown below. This connection merely ensures electrostatic connection of the device and does not meet the requirements for equipotential bonding. 11

5 OPERATION DK46 - DK800 5.1 Start-up 5.2 Operation Make the following checks before starting up the device: Suitability of the materials used for the measuring unit and for the gaskets for adequate resistance to corrosion from the process product. Correct connection of the built-in electrical components. Visual inspection of the single-core non-sheathed cables of the ring sensors, laid inside the indicator, for signs of damage. The limit switches can be set during operation. To do so, first remove the protective cover. Fix the limit switch 2 to the back rail 3 of the variable area flowmeter using the two clamping screws 1. Close the cover immediately after the limit switches have been set. CAUTION! Avoid pinching or damaging the single-core cable of the limit switches when setting the switches and closing the cover. It should be laid in the grooves of the back rail. If the cable is damaged in any way, the variable area flowmeter will need to be replaced! 12

DK46 - DK800 OPERATION 5 5.3 Static electricity Flow-induced static charge In variable area flowmeters, it is possible under field conditions for charge separation to occur in the measuring tube due to the transport of non-conductive fluids and/or when the flow comes into contact with non-conductive internals. In glass devices, it is basically possible for the electrostatic field generated inside the measuring tube to "punch through" to the outside of the device. For that reason, variable area flowmeters need to be permanently grounded by the operator by way of the process connections in order to allow discharge of electrostatic build-up. The operator is also responsible for extending the ground continuity of the process pipeline. If grounding cannot be made via the process connections, e.g. top and bottom connection blocks are made of plastic, the flowmeter should be connected to the local ground potential via the connection to ground. This connection only ensures electrostatic grounding of the device and does not meet the requirements for equipotential bonding. When dust-free gases or liquids are measured, the flow rate should not exceed 20 times the nominal flow rate. The max. allowable working pressure PS printed on the type nameplate is to be noted. 13

6 SERVICE DK46 - DK800 6.1 Maintenance The variable area flowmeter does not require any maintenance under normal operating conditions and when used for the intended purpose. Within the scope of checks required to be carried out in hazardous areas to maintain systems in proper working order, the following visual inspections should be carried out at regular intervals: Inspection of the housing, cable entries and incoming cables for signs of damage. Inspection of the measuring unit for leaks and signs of damage to the glass cone. Include the flowmeter in the periodic pressure testing of the process piping. 6.2 Dismantling Depending on application, however, the measuring function may in unfavourable cases become impaired through soiling of the measuring cone and/or float. The measuring unit should then be cleaned as described in the Installation and Operating Instructions for the non-hazardous-duty versions. In this connection, refer to the notes on dismantling. Electrical connection If at all possible, dismantling should be carried out after the flowmeter has been disconnected from supply. If not possible, observe the boundary conditions for intrinsic safety (e.g. no grounding or connection of different intrinsically safe circuits) during dismantling. Process connections CAUTION! Pressurized pipes to be depressurized before removing the flowmeter. Avoid uncontrolled discharge of residual fluid from the measuring unit. Where environmentally critical products are concerned, carefully decontaminate the wetted parts of the measuring tube after dismantling. Removal and installation are the responsibility of the operator. Maintenance Maintenance work of a safety-relevant nature within the meaning of explosion protection may only be carried out by the manufacturer, his authorised representative or under the supervision of authorised inspectors. 14

DK46 - DK800 SERVICE 6. 15

KROHNE product overview KROHNE - Subject to change without notice. Electromagnetic flowmeters Variable area flowmeters Ultrasonic flowmeters Mass flowmeters Vortex flowmeters Flow controllers Level meters Temperature meters Pressure meters Analysis products Products and systems for the oil & gas industry Measuring systems for the marine industry Head Office KROHNE Messtechnik GmbH Ludwig-Krohne-Str. 5 47058 Duisburg (Germany) Tel.:+49 (0)203 301 0 Fax:+49 (0)203 301 10389 info@krohne.de The current list of all KROHNE contacts and addresses can be found at: