Vehicle and Engine Emissions Testing

Similar documents
SPECIALTY GASES LASAL. laser cutting and welding technologies. Photo courtesy of Alabama Laser.

Gas Mixture Two Components. Gas Mixtures Two Components

Keeping It Simple. Gas Mixtures for Stack Emissions Monitoring.

Laser Gases and Support

Your local gas generation partner. Precision series Modular gas generation solution for GC.

LINEAR TRANSFORMATION APPLIED TO THE CALIBRATION OF ANALYTES IN VARIOUS MATRICES USING A TOTAL HYDROCARBON (THC) ANALYZER

HiQ laboratory gas generators.

Rare Gas Applications

AND EQUIPMENT FOR ENVIRONMENTAL APPLICATIONS (800) B Polk Street Houston, TX

Specialty Gases & Equipment ISO 9001: 2008 CERTIFIED. A Division of Norco, Inc.

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

Gases and welding distributors continue

GASES PROCESS CHEMICAL SPECIALTY. Gases. Pure Gases & Gas Mixtures. VOC Mixtures EPA Protocols. Propane Methane Nitrogen Air Acetylene Propylene Argon

Flare Gas Composition Analysis and QA/QC Lessons Learned and Lessons Lost SPECTRUM ENVIRONMENTAL SOLUTIONS, LLC 1

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

The Gold Standard in Calibration Mixtures

Nonrefillable Cylinders

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Specialty Gases + World-Class Performance

Pure Gases Liquid & High Pressure High Pressure Gas Mixtures Equipment Safety MEDICAL GASES

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Your local gas generation partner. Precision series Modular gas generation solution for GC.

HiQ. Specialty Gases & Specialty Equipment. Precision matters in everything we do.

Life Sciences. Pressure control solutions for your industry.

PRECISION GAS MIXTURES

VIC offers a variety of Calibrated Gas Leaks

PERFORMANCE SPECIFICATION PROPELLANT, HYDROGEN

There is no protection without detection. HiQ specialty gases, equipment and services for environmental monitoring.

There is no protection without detection. HiQ Specialty Gases, Equipment and Services for Environmental Monitoring.

Protocol Gas Verification For Compressed Gas Cylinders Containing Either SO 2, NO or CO. Quality Assurance Plan/Standard Operating Procedure

METHOD 3A - DETERMINATION OF OXYGEN AND CARBON DIOXIDE CONCENTRATIONS IN EMISSIONS FROM STATIONARY SOURCES (INSTRUMENTAL ANALYZER PROCEDURE)

Specialty gases in small cylinders. Combine flexibility and safety with lightweight portability. Specialty gases in small cylinders.

Gas Metrology. SI-traceable: Primary Reference Materials Certified Reference Materials Calibrated Gas Mixtures Interlaboratory Comparisons

Superior Result from Analytical Instruments The constant purity of the nitrogen improves system stability and ensures reproducible results

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

HiQ Specialty Gases and Specialty Equipment. Precision matters. In everything we do.

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Organic Elemental Analysis Series II Nitrogen Analyzer. proven performance. reliable results

Gas-Detection Instruments

GASES NATURAL GAS INDUSTRY SPECIALTY. Gases & Equipment

ONH836 Series: Oxygen/Nitrogen/Hydrogen by Inert Gas Fusion

GAS DETECTION: CALIBRATION GAS

Precision Calibration Gas

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

3 HiQ Specialty Gases and Specialty Equipment. Precision matters in everything we do

Air Liquide one supplier for gases, equipment and services. Delivering expertise to Research Centres and Universities.

N2 Membrane+ Nitrogen Production Systems for Offshore. Where you are. Where you need to be. We are here too.


Gas mixtures. Individual solutions specifically for your application

Improve Process Reliability

ON736 Series: Oxygen/Nitrogen by Inert Gas Fusion

Optimizing Gas Supply for Industrial Lasers

Protocol Gas Verification Program (PGVP)

GASES FIRE & RESCUE SPECIALTY. Gases & Equipment. Medical Gases Liquid & High Pressure Oxygen U.S.P. Nitrogen N.F. Carbon Dioxide U.S.P.

INSTRUMENT INSTRUMENT YL INSTRUMENT

MATHESON s LaserPro Gases and Gas Delivery Equipment

Good things come in threes

High Pressure Compressed Air and Gas Solutions

Technical Manual. Sensepoint XCD Gas Detector

(NIST Special Publication )

Installations & Equipment

The analysis of complex multicomponent

Thermo Scientific Model 146i Principle of Operation

PERFORMANCE SPECIFICATION PROPELLANT PRESSURIZING AGENT, ARGON

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

Non-refillable canister solutions for ultimate portability

Your local gas generation partner. Pocket Guide Discover more at

Supersedes: The copy of this document located on Measurement Canada s website is considered to be the controlled copy.

APPLICATION NOTE. GC Integrated Permeation Device

SAFE AND ENVIRONMENTALLY FRIENDLY

GasTrak Pro TM Delivery/Control Systems

Medical gases and mixture. New horizons for human health

NEW Edge Series Products: OUTFITS and REGULATORS

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

CAPITAL CONTROLS SERIES NXT3000

Customer Responsibilities. Important Customer Information. Agilent 6400 Series Triple Quad LC/MS Site Preparation Checklist

LABORATORY GAS GENERATORS

CHAPTER 16 %UHDWKLQJ*DV0L[LQJ3URFHGXUHV

Calibration Gases. Intrial provides mix of special calibration gases for analyzers and detectors.

Gas-Detection Instruments

MEDICAL EQUIPMENT CATALOG

Elimination of Percent Level H 2 S Calibration Gas from Flare Gas Monitoring Systems Measuring Total Sulfur, H 2 S and BTU.

COAL MINES TECHNICAL SERVICES, GAS DETECTION RELATED SERVICES FOR MINES RESCUE

Calibration Gases. Intrial provides mix of special calibration gases for analyzers and detectors.

Discovery HP-TGA 75/750. Site Preparation Guide

Lecture Bottles Purchase & Disposal

VT900A + VAPOR. Technical data. One Solution. Auto-detection to Ensure Patient Safety. Key benefits and features

UKAS calibration laboratory 8809 Temperature, pressure and electrical signals calibration guide

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

Application Note AN-107

The new CryoEase Service - your No. 1 choice of gas supply

Date of Shipment: Xxxxx 00, 20xx 3402c National Institute of Advanced Industrial Science and Technology National Metrology Institute of

800.Keen.Gas

Improved Reliability in Natural Gas Energy Measurement with the Revised ISO Standard. Gerard Nieuwenkamp - VSL

Gas monitoring using GASMET FTIR

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

EasyLine Continuous Gas Analyzers. So smart, they re simple

UTMB RESPIRATORY CARE SERVICES GUIDELINES Respiratory Care Services Medical Gas Cylinder Storage, Use and Transport

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward

Nitrogen Advantage. Better Tire Pressure Retention. Improved Fuel Economy. Extended Tread Life. Elimination of Oxidation. Reduction in Tire Failures

Transcription:

Vehicle and Engine Emissions Testing Calibration gases and equipment for compliance Benefits and Features Guaranteed analytical accuracy facilitates precise instrument calibration to ensure Part 1065, Part 86 and Euro 6 compliance Cylinder-to-cylinder gas consistency saves time by streamlining calibration procedures NIST-traceability ensures ±1% accuracy for most mixtures NIST-traceable nitrous oxide and ammonia mixtures are available ISO 17025 laboratory accreditation provides added credibility and confidence Short lead times and fast transport by dedicated trucks and drivers assure safe, on-time delivery Cloud computing with SHOP@airliquide online cylinder management solutions reduces administrative costs and helps minimize on-site cylinder inventory Single cylinders, multi-cylinder packs and bulk packaging provide economical gas quantities to meet any application need Proficiency testing programs (including auto/diesel exhaust, NO x and N 2O) are available to evaluate your lab s accuracy Air Liquide America Specialty Gases LLC

Analytical Accuracy and Regulatory Compliance Air Liquide testing and calibration gases deliver classic performance that has become the industry benchmark for compliance and value in vehicle emissions testing. Their purity, accuracy and reliability actually improve analysis reliability for added compliance assurance. They also decrease operational costs by eliminating the likelihood of test cell downtime due to bad gases. Our vehicle emissions testing gases are specifically engineered for tailpipe analysis and bench testing for all mobile engine applications, including automotive, off-road, locomotive, motorcycle, marine, and many other gasoline and diesel applications. Air and nitrogen support products feature low trace impurities that improve the reliability of your analytical results and extend the service life of lab instruments and detectors. Most two-component and multi-component Scott brand mixtures feature NIST-traceability for guaranteed concentration accuracy. Together with our air and nitrogen, Air Liquide provides all calibration gases necessary to comply with Federal and state regulations. Patented ACUBLEND Technology Scott brand two and multi-component calibration gas mixtures feature our patented ACUBLEND gas blending and analysis technology. It allows Air Liquide to blend, mix, compress and analyze gas mixtures in a single operation. Because the ACUBLEND process is so tightly controlled, the mixtures produced are completely homogeneous from top-to-bottom within the cylinder, from cylinder-to-cylinder, and even from batch-to-batch. Identical mixtures can therefore be supplied in as many separate cylinders as needed. Having multiple cylinders that contain identical mixtures can greatly streamline the instrument calibration process. It also enables users to connect multiple cylinders to a common manifold, and allows cylinders containing identical concentrations to be used in separate work areas.

VEHICLE EMISSIONS TESTING Air Pure Gases PART 86 VEHICLE EMISSIONS ZERO (1) PART 1065 (2) ALPHAGAZ 1 VOC FREE UZAM PURITY 99.997% 99.997% 99.997% 99.997% 99.997% CO 2 < 1 ppm < 10 ppm * < 0.3 ppm 315 385 ppm (3) CO < 1 ppm < 1 ppm * < 0.1 ppm < 0.1 ppm H 2 Moisture < 3 ppm < 2 ppm < 5 ppm N 2O < 0.02 ppm NO x < 0.1 ppm < 0.02 ppm < 0.02 ppm** O 2 20 21% 20.5 21.5% 20 22% 20 21% 20 21% SO 2 SF 6 < 0.005 ppm** < 0.001 ppm** THC < 1 ppm < 0.05 ppm < 0.1 ppm < 0.01 ppm < 0.05 ppm Balance Nitrogen Nitrogen Nitrogen Nitrogen Nitrogen Nitrogen Pure Gases PART 86 VEHICLE EMISSIONS ZERO (1) PART 1065 (2) ALPHAGAZ 1 VOC FREE UZAM PURITY 99.999% 99.999% 99.999% 99.999% 99.999% CO 2 < 1 ppm < 10 ppm * < 0.3 ppm < 1 ppm CO < 1 ppm < 1 ppm * < 0.1 ppm < 0.1 ppm H 2 Moisture < 3 ppm < 2 ppm < 4 ppm N 2O < 0.02 ppm NO x < 0.1 ppm < 0.02 ppm < 0.02 ppm** O 2 < 2 ppm < 2 ppm < 2 ppm < 2 ppm SO 2 SF 6 < 0.005 ppm** < 0.001 ppm** THC < 1 ppm < 0.05 ppm < 0.5 ppm < 0.05 ppm < 0.05 ppm * Typical purity; not analyzed: CO 2 < 1 ppm, CO < 1 ppm ** Typical purity; not analyzed (1) Meets Federal Register specifications Title 40, part 86.114-79 and Euro 6 Raw regulations (2) Meets Federal Register specifications Title 40, part 1065.750 and Euro 6 Dilute regulations (3) Available without CO 2 on request

FID Fuel Gas Comparison Our Scott TM brand Standard FID Fuel meets Part 86 requirements. Scott brand FID Fuel 1065 meets Part 1065 requirements. A CO 2 specification can be added for Euro 6 compliance. Standard FID FUEL FID FUEL 1065 H 2 39 41% 39.6 40.4% THC < 0.1 ppm < 0.05 ppm Balance He or N 2 He or N 2 The Environmental Protection Agency (EPA) revised 40CFR Part 1065 in April 2014 to include nitrogen balance gas as an alternative option of He with H 2 for FID Fuel in the automotive industry for hydrocarbon emission testing. Blend tolerance of the FID fuel has also been modified to 40±1% (0.39 to 0.41mol/mol) H 2 in the revised regulations to minimize its impact on analyzer response. Scott Brand Two-Component Calibration Gas Mixtures * Span and Calibration Gases (1) Minor Component Balance Gas Concentration Available NIST-Traceable Accuracy ISO 17025 Accreditation Ammonia N 2 5 5000 ppm 5 250 ppm ±2% No Carbon Dioxide N 2 0.5 ppm 25% 500 ppm 25% ±1% Yes Carbon Monoxide N 2 0.5 ppm 12% 1 ppm 12% ±1% Yes Ethane Air or N 2 0.5 ppm 1% Please Inquire ±1% No Methane Air or N 2 0.5 ppm 1% 1 5000 ppm ±1% Yes Methanol N 2 1 1000 ppm Please Inquire ±2% No Nitric Oxide N 2 0.5 ppm 1% 5 5000 ppm ±1% Yes Nitrogen Dioxide Air or N 2 10 1000 ppm 10 500 ppm ±2% No Nitrous Oxide Air or N 2 1 1000 ppm 1 250 ppm ±1% No Oxygen N 2 0.4 25% 0.4 25% ±1% Yes Propane Air or N 2 0.5 ppm 1% 1 ppm 1% ±1% Yes Testing and Response Factor Gases Minor Component Balance Gas Concentration Available NIST-Traceable Accuracy ISO 17025 Accreditation Acetaldehyde N 2 1 1000 ppm N/A ±2% No Ethanol N 2 1 500 ppm N/A ±2% No Formaldehyde N 2 0.5 30 ppm N/A ±3% No HFO1234yf N 2 10 1000 ppm N/A ±2% No Methanol N 2 1 1000 ppm N/A ±2% No Propanol N 2 1 500 ppm N/A ±2% No * Compliance certificate available as noted. (1) Part 86 requires calibration gases to be ±1% accurate and traceable to NIST, except methanol can be ±2% accurate. Span gases can be ±2% accurate. The NO2 content in NO mixtures must be <5% (Scott brand mixtures contain <1% NO2). For Part 1065, all gases (except methanol) are to be ±1% accurate and NIST-traceable. Methanol is to be ±3% accurate and NIST-traceable. Euro 6 requires ±1% accurate and traceable to a national or international standard. Multi-component mixtures are available please contact your Air Liquide representative.

Lab Analysis Illustrates Proven ACUBLEND Cylinder-to-Cylinder Homogeneity Homogeneous Blends, Cylinderto-Cylinder The laboratory analysis shown at right illustrates the cylinderto-cylinder homogeneity that results when gas mixtures are blended using Air Liquide s patented ACUBLEND dynamic blending technology. All cylinders contain virtually identical concentrations. This homogeneity is achieved not only among all cylinders in a given batch but also from batch-to-batch. Concentration 99.5 98.5 97.5 96.5 95.5 94.5 4820 3036 3131 3769 3834 3934 4073 4332 100 ppm Nitric Oxide 4476 4744 4754 4768 4772 4798 4804 Results Batch Mean -0.25% +0.25% 4815 4828 4832 4836 Cylinder Number Cloud Solutions for Vehicle Emissions Testing Total Control While Optimizing Risk Management Air Liquide s integrated cloud computing approach provides customers involved in vehicle emissions testing with easy-to-use access to all the tools needed to reduce labor intensive paperwork, lower the cost of purchasing, and minimize on-site inventory of mixed and pure specialty gases. All of this while minimizing risk and ensuring compliance with all applicable regulatory requirements. SHOP@airliquide Paperless Inventory Cylinder Management Our online purchasing and inventory management system is an integral part of Air Liquide s cloud computing solution. Use SHOP to order Scott mixtures and ALPHAGAZ pure gases, download invoices and cylinder certs, check credit status, print historical reports, view cylinder balances, receive automatic cylinder expiration alerts, manage your cylinder inventory by serial number, and much more. Your Choice in Packaging Air Liquide gaseous products are available in an extensive variety of packaging configurations to provide you with the most convenient, efficient and economical supply of gas for your application. Options include single cylinders of numerous sizes, multi-cylinder packs of six and 16 cylinders, and VGLs and tube trailers are also readily available. Patented, Innovative Packaging Most Air Liquide cylinders feature our exclusive open style valve cap. The fixed, shockabsorbing design provides added safety during transport and use, and eliminates oldfashioned, screw-on type caps. Plus the ergonomic design makes it easy to maneuver cumbersome cylinders. Some Air Liquide products such as our ALPHAGAZ brand pure gases also feature our SMARTOP with lever activated valve that stops gas flow quickly in an emergency and provides unmistakable indication of valve s open/closed status. SMARTOP also features a built-in pressure gauge that shows cylinder contents to avoid accidentally returning cylinders containing unused gas and a built-in flow restrictor that prevents sudden gas release to prevent injury. Available Cylinder Sizes 49 47AL 16AL SCOTTY 58 16-packs 44 30AL 7AL 6-packs Tube Trailers

Equipment Scott brand is not just calibration gases ChangeOver Systems Monitors High Capacity Gas Purifiers with Indicator Valves DATAL ALert Web- Based Cylinder Gas Management System Safety Mounting Brackets Gas Cabinets Regulators Make Air Liquide your one-stop source for all of your gas distribution needs. Scott brand high-performance gas handling equipment and accessories are the perfect complement to our vehicle emissions testing gases and are guaranteed to be compatible for all compliance applications. Top quality materials of construction protect gas purity and integrity Low maintenance and long service life provide trouble-free service Most items in stock for fast, same-day shipping Ultra-Compact SilcoNert Regulators All Scott equipment meets or exceeds applicable safety regulations Custom gas delivery systems for all types of vehicle emissions testing applications Proficiency Testing for Vehicle Emissions Benefits of Participation Improves credibility of your analytical laboratory capabilities Identifies potential analytical problems confidentially Provides inter and intra-company quality assurance Proficiency testing gas mixtures can be retained as high-confidence master calibration standards Available Programs Diesel Exhaust/Turbine Exhaust Applications: Oxygen concentration is provided with each quarterly sample. Carbon Dioxide: 2 10% Carbon Monoxide: 10 6000 ppm Oxygen: 18 22% Propane: 5 500 ppm High Nitric Oxide and NOx Applications: High level for diesel exhaust; industrial source monitoring. Nitric Oxide: 100 2000 ppm Low Nitric Oxide and NOx Applications: Low level for auto exhaust; industrial source monitoring; stationary turbines. Nitric Oxide: 5 50 ppm Constant Volume Sampling Applications: Diluted automotive exhaust; in-plant air monitoring. Carbon Dioxide: 0.5 2.5% Carbon Monoxide: 5 500 ppm Propane: 5 50 ppm Balance: Blended air, HC Oxygen Applications: Standardized for combustion analyzers; diesel exhaust measurements. Oxygen: 1 21% Customized programs are available please contact your Air Liquide representative. World leader in gases, technologies and services for Industry and Health, Air Liquide is present in 80 countries with close to 50,000 employees and serves more than 2 million customers and patients. NOTE: This brochure is intended for general information purposes only and is not intended as a representation or warranty of any kind, or as a statement of any terms or condition of sale. The information herein is believed to be correct, but is not warranted for correctness or completeness or for applicability to any particular customer or situation. ACUBLEND, ALPHAGAZ, DATAL ALert, Scott, SCOTTY, SHOP@airliquide and SMARTOP are trademarks of the Air Liquide Group. 2014 Air Liquide America Specialty Gases LLC Air Liquide America Specialty Gases LLC 2700 Post Oak Boulevard Houston, TX 77056 Phone: 800.217.2688 Fax: 215.766.2476 Email: ALASG.info@airliquide.com www.alspecialtygases.com All rights reserved 12/14-DKM-1500 1314.1