INSTALLATION & OPERATION MANUAL FOR Stockpot Range

Similar documents
INSTALLATION & OPERATION MANUAL FOR Teppan-Yaki Griddles

INSTALLATION, OPERATION, SERVICE & PARTS MANUAL FOR STOCK POT RANGE MODELS VSP100, VSP200 & VSP300

Operator Manual Gas Griddle / Cheesemelter

INSTRUCTION MANUAL. Gas Ranges

Gas Countertop Griddle

Gas Countertop Hot Plates

Standard Gas Countertop Griddle

OWNERS MANUAL INSTALLATION, OPERATION, & MAINTENANCE INSTRUCTIONS

Your safety and the safety of others are very important.

SERVICE MANUAL SALAMANDER BROILERS RADIANT AND INFRARED 36RB 36IRB VULCAN C36RB C36IRB WOLF

INSTRUCTION MANUAL. Gas Salamander

Natural Gas High-Altitude Conversion Kit For Installations in the United States (2,001 10,000 Feet)

WARNING: FOR OUTDOOR USE ONLY

INSTALLATION GUIDE Gas Rangetops

installation instructions

Installation Instructions WARNING: WARNING: WARNING: LP AND HIGH ALTITUDE LP GAS CONVERSION KIT FOR UNITED STATES INSTALLATIONS

GAS SUPPLY APPLICATION GUIDE

ESG35T * * Installation & Operation Manual. For Service, Call (318) Price: $6.00

WARNING: Installation Instructions. Natural Gas High Altitude Conversion Kit United States Installations Only

UNIVERSAL GAS FRYER Instruction Manual Model #8065NS

GAS FRYER Instruction Manual Model #5099NS

Gas Fired Residential Heating Boilers

USER MANUAL Wok Range

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

Installation and Operation Instructions

Installation Instructions

G AS BBQ GRILLS INSTALLATION INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS BIG TEX VENTED GAS LOGS


INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1*

/2004 US/CA

INSTALLATION & OPERATION MANUAL GAS RESTAURANT RANGES

Gas Conversion Kits CERAMIC HEATER SERIES (1, 2, 3, 4 Burner Units)

WARNING: Gas Conversion Kit Instructions Applies to: Model UDAP, UDAS, UDBP, and UDBS Unit Heaters. General and Warnings FOR YOUR SAFETY

Operator: Save these instructions for future use!

Gas Conversion Kits Push Through (Positive Pressure) Tube Heater Models

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

USER S INFORMATION MANUAL

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

Natural Gas to L.P. Gas Conversion Kit

CASUAL FIRESIDE A HIGHER STANDARD IN QUALITY AND APPEARANCE - SAFE AND BEAUTIFUL OUTDOOR FIRE PIT FOR PROPANE AND *NATURAL GAS

ACCESSORY KIT INSTALLATION MANUAL

ACCESSORY KIT INSTALLATION INSTRUCTIONS

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Natural Gas Conversion Kit

INSTALLATION AND OPERATING INSTRUCTIONS

Natural Gas to L.P. Gas Conversion Kit

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Gas Countertop Hot Plates/Cooktops Operating Instructions

GAS CONVERSION KIT Installation Instructions Range/Rangetop

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Gas Heavy Duty Stock Pot Stove Operating Instructions

Installation Instructions

OPERATING INSTRUCTIONS

ASSEMBLY & OPERATING INSTRUCTIONS

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

HOT SHOT OPERATING INSTRUCTIONS AND OWNER S MANUAL. Model SPC-500. (Propane Torch)

GAS BBQ 4 burner. instructions for. model no: BBQ10

ACCESSORIES MAY BE PURCHASED SEPARATELY.

ROBERT H. PETERSON CO. EPIC BURNER GAS LOG SET

Gas Radiant Countertop Char Broilers Operating Instructions

Propane Conversion Kit Instructions

GAS VALVE RETROFIT KIT Pull Through Tube Heater Models

ROBERT H. PETERSON CO.

Gas Heavy Duty Stock Pot Stove Operating Instructions

INSTALLATION INSTRUCTIONS

Instruction Manual for the Globe Gas Stock Pot Range Model: GSP18G

Gas Countertop Griddles Operating Instructions

JACKSON GRILLS PATIO FIRE

Owner s Manual for Assembly, Operating & Maintenance of

High-Pressure Boiler Inspection Procedures: A Complete Checklist

Instructions for High Altitude Conversion

G96 Series BASOTROL Dual Operator Valve

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY

Viking Installation Guide

Fire's Edge. Fire Pit or Fire Pit Insert Model 100A-M (Manual Operation) OWNER S MANUAL / OPERATING AND MAINTENANCE INSTRUCTIONS

Instruction Manual 742 5/1/2009. Eclipse Ratio Regulators ES Series Version 1

Gas Restaurant Ranges

OCBE-34-01M (P) OUTDOOR CAMPFYRE ELECTRONIC SYSTEM WITH REMOTE CONTROL

G92 Series BASOTROL Automatic Pilot Gas Valve

ROBERT H. PETERSON CO. AUTOMATIC REMOTE LIGHTING SAFETY PILOT SYSTEM WITH VARIABLE FLAME-HEIGHT REMOTE FOR NATURAL OR PROPANE GAS. Model APK-17(M)(P)

The conversion of new certified central heating gas appliances must conform to directions outlined in this instruction.

BPB26-1 AND SSPB26-1 PATIO BASE INSTALLATION INSTRUCTIONS

Installation Instructions For Natural Gas Conversion

WARNING. Gasmate is a registered trademark of: Sitro Group Australia Pty Ltd Aber Ltd - Hamilton, N.Z.

Owner's Manual and Instructions

VR8305 Direct Ignition Combination Gas Control

Dual Solenoid Gas Valve Installation

for Assembly, Operating & Maintenance of Model Big 60 II Gas Utility Stove THIS GAS UTILITY STOVE IS DESIGNED FOR OUTDOOR USE ONLY.

TK Torch Match Lit WARNING: FOR OUTDOOR USE ONLY

VS8420 Millivolt Gas Valve

Operator: Save these instructions for future use!

APPROVED FOR USE IN SOUTH AFRICA STAINLESS STEEL STOVE

Thanks for shopping with Improvements! Monterey Propane Fire Column Item #574852

Propane Conversion Kit Instruction

Gas Vertical Type Fryer Operating Instructions

Types 749B and R130 Changeover Manifolds

OWNER'S MANUAL WARNING WARNING WARNING WARNING. Factory No.: HYFP Item No.: 67668ST

CastCreations PRODUCT DESCRIPTION. Redwood Stump Fire Pit Item #: C1002. CastCreations Ph: Aurora, Utah

Transcription:

INSTALLATION & OPERATION MANUAL FOR Stockpot Range MODELS MLS VSP100 ML-052822 VSP200 ML-052823 VSP200F ML-769292 www.vulcanhart.com MODELS MLS WSPR1 ML-760600 WSPR2 ML-760601 WSPR2F ML-769292 www.wolfrange.com VSP100 WSPR2F ITW Food Equipment Group, LLC 3600 North Point Blvd. Baltimore, MD 21222 RETAIN THIS MANUAL FOR FUTURE USE FORM F-36951 (04-07)

IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE OBTAINED FROM THE LOCAL GAS SUPPLIER. IMPORTANT IN THE EVENT A GAS ODOR IS DETECTED, SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE. FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT. IN THE EVENT OF A POWER FAILURE, DO NOT ATTEMPT TO OPERATE THIS DEVICE. - 2 -

INSTALLATION, OPERATION AND CARE OF STOCKPOT RANGE GENERAL Stockpot ranges are designed for commercial use only and feature fast, efficient gas heat. Each burner is controlled by an adjustable gas valve. Heavy-duty, cast iron top grate(s) are easily removed for cleaning when cool. A grease drawer is provided to collect fat run-off; it opens to the front for inspection or drain-off. Model Number of Burners BTU/hr Input Rating VSP100, WSPR1 2 110,000 VSP200, WSPR2 4 220,000 VSP200F, WSPR2F 4 220,000 UNPACKING INSTALLATION Immediately after unpacking, check for possible shipping damage. If the stockpot is found to be damaged, save the packaging material and contact the carrier within 15 days of delivery. Before installing, verify that the type of gas (natural or propane) and the clearance dimensions (see below) agree with the specifications on the rating plate which is located at the back of the stockpot. LOCATION The installation location must be kept free and clear of combustibles. Do not obstruct the flow of combustion and ventilation air. DO NOT install the stockpot adjacent to open burners or fryers. Sufficient air should be allowed to enter the room to compensate for the amount of air removed by any ventilating system and for combustion of the gas burners. Do not obstruct the air flow into and around the appliance. Do not obstruct the flow of flue gases through and above the stockpot top grate. Position the stockpot in its final location. Check that there are sufficient clearances to service the stockpot and to make the required gas supply connection(s). Provide 24" clearance at the front for cleaning, maintenance, service and proper operation. Minimum Clearance Combustible Construction Non-Combustible Construction Rear 24 4 Sides 18 0-3 -

INSTALLATION CODES AND STANDARDS The Stockpot Range must be installed in accordance with: In the United States of America: 1. State and local codes. 2. National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest edition). This shall include but not be limited to: NFPA #54 Section 10.3.5.2 for Venting. Copies may be obtained from The American Gas Association Accredited Standards Committee Z223, @ 400 N. Capital St. NW, Washington, DC 20001 or the Secretary Standards Council, NFPA, 1 Batterymarch Park Quincy, MA 02169-7471 NOTE: In the Commonwealth of Massachusetts All gas appliances vented through a ventilation hood or exhaust system equipped with a damper or with a power means of exhaust shall comply with 248 CMR. 3. NFPA Standard # 96 Vapor Removal from Cooking Equipment, latest edition, available from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. In Canada: 1. Local codes. 2. CAN/CSA-B149.1 Natural Gas Installation (latest edition) 3. CAN/CSA-B149.2 Propane Installation Code (latest edition), available from the Canadian Gas Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 1R3 GAS PRESSURE REGULATOR INSTALLATION Gas regulator pressure is preset at 5 Water Column (W.C.) for natural gas, and 10 W.C. for propane gas. Minor adjustments may be required based on site specific gas pressure. Install the regulator as close to the stockpot on the gas supply line as possible. Make sure that the arrow on the underside of the regulator is oriented in the direction of gas flow to the stockpot (Fig. 2) and the regulator is positioned with the vent plug and adjustment screw upright (Fig. 3). Fig. 2 Fig. 3 The minimum supply pressure (upstream of the regulator) should be 7-9 W.C. for natural gas and 11-12 W.C. for propane gas. At no time should the hotplate be connected to supply pressure greater than ½ psig (3.45 kpa) or 14 W.C. - 4 -

LEVELING The Stockpot Range is equipped with legs. Turn the feet at the bottom of the legs in or out to level the Stockpot Range in the final installed location. VENTILATION HOOD The stockpot should be installed under a suitable ventilation hood. For safe operation and proper ventilation, keep the space between the stockpot and vent hood free from any obstructions. GAS CONNECTION The data plate on the lower right side of the charbroiler indicates the type of gas your unit is equipped to burn. DO NOT connect to any other gas type. CAUTION: All gas supply connections and any pipe joint compound must be resistant to the action of propane. Purge the supply line to clean out any dust, dirt, or any foreign matter before connecting the line to the unit. Codes require that a gas shut-off valve be installed in the gas line ahead of the charbroiler. The gas supply line must be at least the equivalent of ¾ iron pipe. 72-inch units should be connected to the gas supply on both the left and right sides to provide adequate gas flow. A pressure regulator is supplied and must be installed outside of the broiler when making the gas supply connection. Standard orifices are set for 5"WC (Water Column) for Natural Gas 10"WC (Water Column) for Propane. Use the 1 / 8 pipe tap on the burner manifold for checking pressure. Make sure the gas piping is clean and free of obstructions, dirt, and piping compound. An adequate gas supply is necessary. Undersized or low pressure lines will restrict the volume of gas required for satisfactory performance. A maximum supply pressure of 7" W.C. for natural gas and 11" W.C. for propane gas is recommended. With all units operating simultaneously, the manifold pressure on all units should not show any appreciable drop. When testing the gas supply piping system, if test pressures exceed ½ psig (3.45 kpa), the charbroiler and its individual shutoff valve must be disconnected from the gas supply piping system. When test pressures are ½ psig (3.45 kpa) or less, the charbroiler must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the system. WARNING: PRIOR TO LIGHTING, CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR LEAKS. USE SOAP AND WATER SOLUTION. DO NOT USE AN OPEN FLAME. - 5 -

OPERATION WARNING: THE STOCKPOT RANGE AND ITS PARTS ARE HOT. BE CAREFUL WHEN OPERATING, CLEANING OR SERVICING THE STOCKPOT RANGE. CONTROLS The burner is in two sections, controlled by two heavy duty infinite control valves. The center Star section (Fig. 2) is on separate burner with an input of 55,000 BTU/hr. It is controlled by the right burner valve knob. The outer circle of the burner (Fig. 2) is the other separate 55,000 BTU/hr input burner, controlled by the left burner valve knob. These two separate burners provide heat flexibility. With one burner off and the second burner set low, up to both burners full on, you can move from low simmer on up to 110,000 BTU/hr input. PILOT VALVE SCREW INNER BURNER OUTER BURNER Fig. 1 Fig 2. LIGHTING INSTRUCTIONS 1. Turn all burner valves to OFF position and wait 5 minutes. 2. Turn gas shutoff valve ON. 3. Light standing pilot with a lit taper. Adjust pilot to ¼ high flame, if necessary, by turning pilot valve adjusting screw (see Fig. 1) counterclockwise to increase or clockwise to decrease flame. 4. Turn burner valve to ON position. 5. If pilot does not light, turn main gas supply OFF and repeat steps 1 through 4. TO COMPLETELY SHUTDOWN THE BURNERS AND PILOT LIGHTS For complete shutdown: Turn the main gas supply valve OFF. - 6 -

CLEANING Top grate(s) may be immersed in strong commercial cleaning compound overnight. In the morning, rinse with hot water to remove any residues of cleaning compound. Stainless steel surfaces may be cleaned using damp cloth with mild detergent and water solution. Places where fat, grease, or food can accumulate must be cleaned regularly. MAINTENANCE WARNING: THE STOCKPOT RANGE AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING, CLEANING, OR SERVICING. SERVICE Contact your local Service Agency for any repairs or adjustments needed on this equipment. TROUBLESHOOTING Pilot Outage PROBLEM Improper burner combustion Poor Ignition 1. Pilot flame too low 2. Restriction in pilot orifice 3. Restriction in pilot valve Improper ventilation POSSIBLE CAUSES 1. Insufficient gas input 2. Poor air-gas adjustment 3. Restriction in pilot orifice 4. Restriction in main burner ignition port 5. Restriction in control valve 6. Restriction in gas orifice - 7 -