CRYO INDUSTRIES. Liquid Helium Research Dewars

Similar documents
RC102 & RC110 Sample in Vacuum Continuous Flow Cryogenic Workstation Cryostats

Variable Temperature Storage Dewar Mount Inserts

Microscopy Cryogenic WORKSTATION. Performance by Design

CRYO. SuperVariTemp Magnet Inserts

Storage and transfer of cryofluids

Baffles and Traps Cryotrap

Procedure for Operating Columbia (Nevis) LHe Electron Bubble Chamber Cryostat. Version 5.1

JANIS OPERATING INSTRUCTIONS FOR SUPERCONDUCTING MAGNET CRYOSTATS

Current Leads for Cryogenic Systems

Short Introduction to Cryo-Pumps and Refrigerators. Dr Graham Rogers Leybold UK Ltd.

EXPERIENCE WITH CRYOGENICS SAFETY, PROBLEMS AND SOLUTIONS

Loss of Vacuum Experiments on a Superfluid Helium Vessel

Liquid Helium Bath Cryostat

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

Table of Contents Want full page pictures with most important parts labeled in the beginning.

Liquid Gas Cylinder (LGC)

Magnet and RF Cavity Test Stand Design. Tom Peterson, SLAC USPAS January, 2017

PRODUCT GUIDE Spring 2015

Vacuum Jacketed Piping Solutions

First Experimental Data of the Cryogenic Safety Test Facility PICARD

ALU-CD 12, ALU-CD 25, ALU-CD 35, ALU-CD

SHMS. Downstream Beamline. Large SHMS/HMS Angles (Config-1) Large SHMS / Min HMS Angle (Config-2) Dan Young Ext /26/2015 1

Vacuum. Dry Turbo Pumping Stations. Roughing Pumps for 1 K Helium Pots and Lambda Refrigerators. Hermetically Sealed Pumps for He3 Recirculation

Oxford Instruments Austin, Inc.

Operating Manual ALU 7 - ALU 10 - ALU 20 - ALU 26 ALU 35 - ALU 60 - ALU 100

Cryogenics is the science of ultra low temperatures. Low temperatures are achieved by the liquefaction of gases.

KEYSTONE. A C E C O E n v i r o n m e n t a l C o m p a n y. Bulletin 10-B

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

VERTICAL BLADDER TANK

from Thames Cryogenics Ltd Total Cryogenic Solutions Cryogenic Cluster Day 22/09/2010

Bruker BioSpin NMR CASE. System Requirements Manual. Version. NMR Spectroscopy. think forward

SPECIFICATION FOR AN MRBR 9.4 TESLA/310MM/AS CRYO-COOLED MAGNET SYSTEM

v. Size shall be specified on drawings.

THE HF-210 SERIES. Operating and Service Manual. Series includes all variants of HF-210/211. Issue A October 2014 *Section 6.

HORIZONTAL BLADDER TANK

Dilution Refrigerator manual

Model MTB-ASME Vertical Bladder Tanks

REFRIGERATION SYSTEM COMPONENTS

Model MTB-ASME Horizontal Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks

VACGEN. Vacuum Components. Product Overview

TRADITIONAL HIGH VIBRATION HOSE SYSTEM THE STANDARD FOR MANY AUTOMOTIVE APPLICATIONS

ADAPTABILITY & PRECISION

Self-operated Pressure Regulators for special applications

Pump out insert (condenser and still lines) overnight with turbo pump

Safety Aspects and Design of the Vent Isolation Chamber. Prepared: W.M. Snow Checked: H. Nann Approved: W. M. Snow

Trillium US Inc. Cryo-Plex 10 Cryogenic High Vacuum Pump User s Manual Rev A / November 2015

Research activities on cryogenic safety

MEDICAL EQUIPMENT CATALOG

VACUUM & AIRLESS. Select from Kimble vacuum traps, manifolds, Schlenk tubes, adapters, and bubblers for your vacuum and airless glassware needs.

MONROE BROTHERS LTD Customer Sigmaphi Project JLab Dipole Safety Relief MB / Description Chimney Vent Capacity & Pressure Drop 301 Issue 1

Barrier Development and Evaluation Methodology. D.S. Musgrave 1 1 Thermal Visions, Inc., Granville, USA

National Accelerator Laboratory

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

Cryostream 800 Series

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

CanNeed-DSST-100 Digital Secure Seal Tester --- To evaluate the secure seal quality of PET bottles, glass bottles and cans

Chapter 8: Cryo-sorption pumps

Water. VAG DUOJET Automatic Air Valve Single-chamber type PN 10/16/25/40 - DN KAT-A 1912

CLEAN AGENT FIRE EXTINGUISHING SYSTEM MX 1230 Extinguishing Agent Cylinders

Oxford Instruments Austin, Inc.

1/2 to 2-1/2 NPT; 0 to 230 PSI Advantages / Benefits

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

EXERCISE 2: THE VACUUM SYSTEM

Description Advanced Features Typical Applications

Load Responsive Multilayer Insulation Performance Testing

INSTRUCTION MANUAL FOR EBA MINUTE SELF-CONTAINED SELF RESCUER (SCSR) Manual Number: NH13747 Revision: A, ECN 2384 September 7, 2001

PRO-50 Instrument Supply Regulator

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

Horizontal Bladder Tanks

Bourdon tube pressure gauges for chemical applications EN 837-1

Vertical Bladder Tanks

Manual Solvent Purification System. Innovative Technology, Inc.

STANDARD OPERATING PROCEDURES

Bourdon tube pressure gauges with glycerine filling, for chemical applications EN 837-1

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

Grundfos GT TANK Keep it safe

GREIG FILTERS, INC. OPERATION MANUAL

BUTTERFLY VALVES. Toll Free (877) - ICFLUID -2-

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

VACUUM CHAMBER MANUAL

attoliquid Liquid Research Cryostats

HP/UHP Spring-Loaded Regulator

Figure 1: Hydrostatic Pressure Forces Are Perpendicular to the Surface

DRAFT. Operating Procedures for the NPDGamma Liquid Hydrogen Target in TA-53, Building MPF-35

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

Y692VB Series Vacuum Breaker

Sample C ylinde rs, Acce ssorie s, and O utage Tube s

UHP - UHV APPLICATIONS

Hall C SHMS Q2, Q3, and Dipole: Magnet Pressure Safety. Eric Sun. October 12, Experiment Readiness Review of Physics Division.

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

PILOT OPERATED RELIEF VALVE SAFETY PRODUCTS THAT PROTECT EQUIPMENT, LIVES & THE ENVIRONMENT

Cryogenics of SRF Spoke Cavity Development at SMTF

Coiling Tube with Twist-Proof Fitting

Model: 8126/ /50 Liter LN2 Supply Tank. Operating and Maintenance Manual Manual No: Rev. 1

Procedure for Filling 2 T Bruker Magnet with Nitrogen

Pressure Testing & Isolation Plugs

64 Series Pressure Reducing Regulators

Transcription:

Liquid Helium Research Dewars

Liquid Helium Research Dewars Cryo Industries Liquid Helium Research Dewars are finely designed and manufactured using the highest quality materials. A Liquid Helium reservoir dewar with surrounding liquid nitrogen shield and variable temperature insert defines the most popular research dewar. The sample is fast change, top loading and can be manipulated while operating. CIA s LHe research dewars are characterized by a large direct opening to liquid helium. Superconducting magnets and other large inserts are introduced into liquid helium from the top. Inserts are usually supported and sealed by the dewar s top flange. An optical or non-optical tail can be easily integrated into the dewar through a demountable bottom flange. The LHe research dewars are available in either liquid nitrogen shielded or vapor shielded styles, and can be manufactured from: Stainless Steel: All welded construction, very rugged and highly polished for great looks. Aluminum Fiberglass: Vapor shielded aluminum fiberglass is the most popular style for bucket dewars. This style dewar fills fastest and requires no liquid nitrogen maintenance. Belly options are available to increase the liquid helium volume. The epoxy fiberglass necks have helium gas diffusion barriers. The highest efficiency is obtained by a combination of hard shields and multiple soft shields, located in the insulating vacuum space. Fiberglass: Constructed from all G-10 (Epoxy Fiberglass), this liquid helium dewar design uses no metal or metal vapor barriers. Cryo has a team of engineers and physicists who will work with you to create a liquid helium research dewar that meets your specific research needs.

LN 2 Shielded Aluminum & G-10 LHe Dewar CAPPED OFF EVACUATION PORT WITH NW25 FLANGE AND DEMOUNTABLE VALVE OPERATOR (3) LN2 PORTS WITH SAFETY PRESSURE RELIEF AND 3/8" DIA. QUICK CONNECT Aluminum - Epoxy Fiberglass (G-10) Dewars are available in any combination of neck diameters, liquid helium volumes, tail &/or dewar lengths! (8) 1/4-20 TAPPED HOLES EQUALLY SPACED ON A 7.00 DIA, B.C. DEWAR SAFETY PRESSURE RELIEF TOP VIEW 5.88 I.D. (4) LIFTING LUGS 20.00 6.00 I.D. G-10 LIQUID NITROGEN RESERVOIR 52.75 14.75 24.00 O.D. (ALUM.) 16.00 O.D. (ALUM.) LIQUID HELIUM RESERVOIR SUPERINSULATION 6.12 I.D. (ALUM.) 13.00 Model No.: AFD-2420-NSB IS THE SOLE PROPERTY OF PERMISSION OF IS STRICTLY Industries of America Inc. 11124 S WILLOW ST., Manchester N.H. 03103 LIQUID NITROGEN SHIELDED ALUMINUM AND G-10 LHe DEWAR

Stainless Steel Closed N2 Reservoir LHe Dewar #2-274 O-RING 10.25 I.D. (260 mm) (6) 1/4-20 TAPPED HOLES ON A 11.00 (279.4 mm) DIA. B.C. 5.00 (127 mm) VACUUM VALVE WITH SAFETY PRESSURE RELIEF AND PROVISION FOR T/C VACUUM GAUGE PROVISION FOR SENSOR INSERT LN 2 VENT 6.00 (152 mm) LN 2 FILL NW-40 FLANGE 48.12 (1222 mm) NW-50 FLANGE 2.00" O.D. PUMPING ARM WITH SAFETY PRESSURE RELIEF TOP VIEW LIFTING LUGS LIQUID NITROGEN RESERVIOR 51.00 (1295 mm) 15.00 O.D. (381 mm) 13.50 O.D. (343 mm) 11.00 O.D. (279 mm) 10.OO O.D. (254 mm) Open neck or bucket dewars available with choice of helium reservoir diameters from 3 inches and up. ALUMINUM RADIATION SHIELD WITH VACUUM PORT Model No.: 10CR-CN CHARCOAL GETTER IS THE SOLE PROPERTY OF PERMISSION OF IS STRICTLY Industries of America, Inc. CLOSED NITROGEN RESERVOIR LIQUID HELIUM RESEARCH DEWAR

Vapor Shielded Liquid Helium Dewar 3.50 2.438 Ø5.875 I.D. 4.000 6.00 I.D. G-10 13.000 VACUUM VALVE 1.75 1.56 (3) LIFTING LUGS (ROTATED INTO VIEW) BURST DISK PRESSURE RELIEF 1.68 3.000 Ø8.25 O.D. Ø7.25 O.D. 50.000 Ø6.00 I.D. 54.000 Ø12.38 O.D. 36.000 This LHe Research Dewar features multiple vapor shields and is available in various LHe reservoir diameters! MULTI LAYERED SUPER INSULATION 1.000.500 Model No.: VSD-591M4 IS THE SOLE PROPERTY OF PERMISSION OF IS STRICTLY Industries of America, Inc. 11124 South Willow Street, Manchester, NH 03103 VAPOR SHIELDED LIQUID HELIUM DEWAR

Vapor Shielded Liquid Helium Belly Dewar EVACUATION PORT WITH NW25 FLANGE (RE-PUMP REQUIRES A DEMOUNTABLE VALVE) 6.88 I.D. (8) 1/4-20 TAPPED HOLES EQ. SP. ON A 8.00 DIA. B.C. BURST DISK PRESSURE RELIEF 15.94 (3) LIFTING LUGS 20.19 O.D. ALUM. 7.00 I.D. G-10 VACUUM MAINTENANCE SYSTEM MULTIPLE VAPOR COOLED SHIELDS 21.94 'BELLY'=APPROX. 55 LITERS 47.75 16.00 O.D. ALUM. 51.75 APPROX. MULTI-LAYERED INSULATION 7.12 I.D. ALUM. Industries of America, Inc. 11124 S. Willow Street, Manchester, N.H. 03103 Model No.: VSD-1818-R7 IS THE SOLE PROPERTY OF PERMISSION OF IS STRICTLY VAPOR SHIELDED LIQUID HELIUM 'BELLY' DEWAR

All Fiberglass (G-10) LHe Dewar 3.9 (99 mm) TOP FITTING 3.00 5.00 EVACUATION VALVE WITH DEMOUNTABLE OPERATOR Non-Metallic Non-Magnetic Epoxy Fiberglass LHe Dewar features NO metal or metal vapor barriers. LIQUID NITROGEN RESERVOIR 950 mm 860 mm (37.402) (33.858) 4.00" I.D. (101mm) 4.50" I.D. 6.50" I.D. 7.00" I.D. (178mm) 7.25" O.D. (184 mm) 1.500 Model No.: EFD-675-DNM IS THE SOLE PROPERTY OF PERMISSION OF IS STRICTLY Industries of America Inc. 11 Industrial Way, Atkinson N.H. 03811 ALL FIBERGLASS LIQUID HELIUM RESEARCH DEWAR