Liquid level switch BM 34

Similar documents
Liquid level instruments BM 24 /BM 51

Level transmitter LT 100

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

GA24 Technical Datasheet

VA40 - VA45 Technical Datasheet

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

3000 Series OPTIMASS Mass Flowmeter. Stainless Steel Hastelloy

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

Magnetic Level Gauges

DK46 - DK800 Supplementary instructions

Torque Tube TB300 Digital Transmitters

Level switches Series LD Vibrating fork level switch for liquids and solids

Installation and Operating Instructions Bypass Flow Meter DST

Variable area flowmeter F VA 250

Level switches Series LD Vibrating fork level switch for liquids and solids

THE EXPERT IN LEVEL AND FLOW

Pressure Relief Valve DHV 718

Monitoring device NTS 30

NC MAGNETIC FLOAT SWITCHES FOR LIQUIDS

GA24. GA24 Handbook. Variable-area flowmeter. KROHNE 02/ MA GA24 R01 en

Pressure Reducing Valve DMV 755

Variable Area Flow Meters. VS Series

Pressure Reducing Valve DMV 750 set range: bar

SITRANS F I Gardex. Flowmeter. SITRANS F I Intra/Prima. Flap Flowmeter. Contents. English. General 1. SITRANS F I Gardex 2. SITRANS F I Intra/Prima 3

NC MAGNETIC FLOAT SWITCHES FOR LIQUIDS

L21S/SR/ST Glass Level Gauges

Magnetic level switch type MR783 Instruction Manual

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

Pressure Reducing Valve DMV 750

Features. Up to 6 switch points Minimum degree of protection IP65 Optional temperature sensor PT1000 or thermostat Potted electrical contacts

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

Level MEASUREMENT 1/2016

C-Flow Coriolis Mass Flow Meters

Glass tube flowmeters Series 2000

Product information. Capacitive. Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69. Document ID: 29983

BM 26 A. Installation and operating instructions. Bypass Level Indicator. For level or interface measurement of liquids

Pressure Reducing Valve DMV 755 set range: 1,0-9,0 bar

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

Variable Area Flow Meters

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Technical Information. Overview Rotameter. TI 1R1A0-E-H 4th edition

Pressure Reducing Valve

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Bourdon tube pressure gauges with glycerine filling, for chemical applications EN 837-1

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

Float Switches. for Liquids NSM, NSP, NAB, NEC, NST, NSE

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter

Instrumentation & Data Acquisition Systems

Pressure Measurement Single-range transmitters for general applications

Target disk flowmeter Series DP. Instructions manual DP65 DP500. R-MI-DP Rev.: 4 English version

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

KOBOLD KSM FLOWMETER. User Instructions

200A Series ELECTRONIC LEVEL TRANSMITTER

Ultrasonic. Continuous level measurement. Overview Page 64 VEGASON series 60 Page 66 AL-EN

9700 Transmitter Submersible hydrostatic level transmitter

Pressure relief valve DHV 725 set range: 0,2-10,0 bar

Expansion Thermometers Stainless Steel Series, Model 70

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

Pressure Relief Valve DHV 718

How to specify a product. Process Sensors and Mechanical Instruments

Armatures for analytical probes

deltaflowc deltaflowc Venturi or Probe

INVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking:

High-performance submersible pressure transmitter For level measurement Model LH-10

Bourdon tube pressure gauges for chemical applications EN 837-1

Rosemount 2130 Extreme Temperature Vibrating Fork Liquid Level Switch

SITRANS P measuring instruments for pressure

Ultrasonic. 58 Overview VEGASON 60 VEGASON 61, 62, 63

MLS Series Liquid Level Switches. Installation and Operations Manual Section 15

OPTIBAR P 1010 C Technical Datasheet

Instruction presentation Special valves

Product information. Capacitive. Level detection with bulk solids VEGACAP 62 VEGACAP 65 VEGACAP 66 VEGACAP 67. Document ID: 29982

Bourdon tube pressure gauge for diaphragm seals

Pressure Switches Application Guideline

Model DE-1, VDE-1 and DE-2 Air Release Heads

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

FVA Trogflux variable area flowmeter. Operating Instructions. MECON GmbH 05/2013 OI_FVA_Trogflux_EN

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

SITRANS P measuring instruments for pressure

Expert Hydrostatic Level Transmitters

Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases

Position locking powerful chuck. CKL2-*-HC Series CKL2-40CS-HC CKL2-50CS-HC CKL2-63CS-HC CKL2-80CS-HC Compressed air to

ProcessMaster FEP610 Electromagnetic flowmeter

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Climatic Independent Level Sensor LAR

Technical Data Sheet T 2025

Differential pressure

DISSOLUTION TEST FOR SOLID DOSAGE FORMS

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

INSTRUCTION MANUAL. FLOAT TYPE LEVEL TRANSMITTER HT-100R Series HITROL CO., LTD.

For Multi-Parameter Meters see mvx

Transcription:

KROHNE 09/2001 7.02370.21.00 GR/PRINTO Liquid level switch Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level measuring instruments Communications engineering Engineering systems & solutions

Liquid level switch For use in potentially hazardous environments Operating principle A float guided on a non-magnetic tube follows the level of the liquid surface, thereby actuating up to 6 reed contacts, monostable or bistable, inside the tube via a built-in magnet system. Types of contacts All contacts are fitted to a rod with a clamping device. Where switching points are not known or the contact has to be adjustable the clamps are loosely attached. For overfill protection systems, the uppermost contact is non-detachable. The length of the guide tube and installation height of the reed contacts are specified from the lower edge of the screw connection or mounting flange. Approved for hazardous duty and as part of an overfill protection system Up to 6 freely adjustable or preset switching elements Temperature range 200 +200 C ( 328 +392 F) and operating pressure max. 40 bar (580 psig) 0.3 6 m (1 20 ft) tube length Monostable reed contacts These switches are only actuated as long as the float and magnetic system are at an equal height. If the float moves away, the contact returns to its original setting. The achieved switching state can be maintained with an auxiliary relay. Floats with a ring magnet system are used. Bistable reed contacts These switches are actuated by the float s magnetic system and remain in the switching state. Therefore, they provide a clear indication of the float s location, i.e. above or below the switch, without the need for an auxiliary relay. The switch setting is retained until the float moves past the switch in the opposite direction. Floats with a radial magnetic system are used. A variety of materials permits use also in aggressive media Float with ring magnet system Float with radial magnet system 34

Range of application is ideal wherever liquid levels need to be monitored in process and storage tanks. Typical liquids are: Water and aqueous fluids Acids / alkalis Organic and inorganic solvents Special versions Interface detection, TS If two liquids with different densities are stored in one tank, the level of the interface can be measured using a special interface-type float. The weight and buoyancy of the float are such that it floats on the heavier and sinks in the lighter liquid. The minimum difference in density between both liquids should be greater than 100 g/l (6.24 lb/ft 3 ), and the float must be fully immersed in the light liquid. If the lighter liquid is not always stored in the tank, this must be specified on ordering to ensure appropriate float design. For ships tank with test device, /T In the /T version, an additionally installed rod magnet in the tube can be raised with a test knob. By means of a magnetic coupling, a sleeve on the outside of the tube follows this motion. It is thus possible to raise the float to contact point, thus permitting a check of the instrument s switching functions. If the float has developed a leak and filled with liquid, the magnetic coupling breaks off due to the heavier weight and no contact is produced. Guide tube centering aid For agitated liquids, a centering device welded to the tank bottom is recommended to avoid buckling of the guide tube. For approved devices, a bottom centering device is mandatory where the length of the guide tube is > 3000 mm (> 9.8 ft). Product Overview Vibration Continuous, non-contact Switches Ultrasonic Radar Ultrasonic Buoyancy Capacitance Materials /coatings For use in aggressive products, all wetted parts can be coated with PVC, PP or PTFE. Other materials are titanium or Hastelloy-C4. Continuous, contact Ultrasonic Buoyancy TDR Dimensions in mm (inches) 35

Responsibility for suitability and intended use of our instruments rests solely with the purchaser. Technical data Length (guide tube) 0.3 6 m (1 19.7 ft) Switching accuracy ± 3 mm (± 0.12 ) Max. allowable operating pressure Standard max. 40 bar (580 psig) /F/WB, /F/WN max. 3 bar (43.5 psig) /Ex/Z0, /F/Ex/Z0 max. 35 bar (508 psig) depending on flange pressure rating and float pressure resistance. Process temperature Standard 55 +150 C ( 67 +302 F) Option 200 +200 C ( 328 +392 F) /Ex/Z0 20 +150 C ( 4 +302 F) /F/WB 20 +60 C ( 4 +140 F) /F/WN 20 +200 C ( 4 +392 F) /F/Ex/Z0 20 +75 C ( 4 +167 F) Operating data Min. density Standard, /Ex/Z0 0.4 kg/l (25 lb/ft 3 ) Option, /F/WB, /F/WN, /F/Ex/Z0 0.5 kg/l (31 lb/ft 3 ) Viscosity* Standard 5000 m Pa s For approved instruments 1000 m Pa s Solids content* 100 g/l (6.24 lb/ft 3 ) =^ 10% dry substance Particle size* 200 µm Reed contacts Type/number max. 6 monostable or 6 bistable changeover contacts (bistable contact not possible with F/WN, F/WB or F/Ex/Z0) Version Standard F/WN, F/WB Ex/Z0, F/Ex/Z0 Operating voltage 65 V 30 V 20 V Max. contact rating 40 W / 60 VA 0.9 W (VA) 200 mw (VA) Max. current switched 1 A 30 ma 40 ma Contact spacing monostable changeover contact > 50 mm (1.97 ) bistable changeover contact > 70 mm (2.76 ) Switching hysteresis 5 mm (0.2 ) Holding range 17 mm (0.67 ) Lowermost switching point < guide tube length 130 mm (5.12 ) Uppermost switching point > 100 mm (3.94 ) distance from bottom edge of flange Connection Standard DIN 2501, Form C DN 25, PN 40 Option DIN 2501, Form C DN 40 DN 150/PN 6 PN 40 ANSI B 16.5 1 6 150/300 lb/rf DIN 2999 G 11/2 A (SW 50 mm wrench) Plastic-coated flanges DIN 2501, Form C DN 50/PN 6 PN 40 ANSI B 16.5 2 150/300 lb/rf /T DIN 2501, Form C DN 50/PN 40 ANSI B 16.5 2 150/300 lb/rf Information on higher pressure ratings and other standards available on request Protection category to EN 60529 / IEC 529 IP 56, equivalent to NEMA 3 Materials Flanges Screw connection Guide tube Float Housing Stainless steel 1.4571 (316 Ti) Stainless steel 1.4571 (316 Ti)/titanium plated Stainless steel 1.4571 coated with PVC, PP or PTFE Stainless steel 1.4571 (316 Ti) See instrument versions See Selection of float type Stainless steel 1.4571 (316 Ti) * Relevant for instruments approved as part of an overfill protection system. 36

Selection of float type Shape Dimensions Materials Min. density Max. allowable Product temperature (diameter x height x wall-thickness) operating pressure min. max. in mm in inches kg/l lb/ft 3 bar psig C F C F Standard versions without explosion protection Cylinder 97 x 145 x 1.0 3.82 x 5.71 x 0.04 Stainless steel 1.4571 (316 Ti) 0.85 53.07 40 580-200 -328 200 392 Cylinder 97 x 145 x 0.6 3.82 x 5.71 x 0.02 Stainless steel 1.4571 (316 Ti) 0.70 43.70 25 363-200 -328 200 392 Ball 142 x 145 x 0.7 5.59 x 5.71 x 0.03 Stainless steel 1.4571 (316 Ti) 0.40 24.97 25 363-200 -328 200 392 Ball 142 x 145 x 1.0 5.59 x 5.71 x 0.04 Stainless steel 1.4571 (316 Ti) 0.50 31.21 40 580-200 -328 200 392 Cylinder 97 x 145 x 1.0 3.82 x 5.71 x 0.04 Titanium 0.45 28.09 35 508-160 -256 200 392 Ball 142 x 145 x 1.0 5.59 x 5.71 x 0.04 Titanium 0.40 24.97 35 508-160 -256 200 392 Cylinder 94 x 100 3.70 x 3.94 PVC 0.60 37.46 4 58-40 -40 40 104 Cylinder 94 x 100 3.70 x 3.94 PP 0.40 24.97 4 58 10 50 60 140 Cylinder 130 x 165 5.12 x 6.50 Hard glass 0.70 43.70 16 232-50 -58 200 392 Cylinder 94 x 100 3.70 x 3.94 PVDF 0.70 43.70 4 58-40 -40 100 212 Cylinder 140 x 175 x 1.0 5.51 x 6.89 x 0.04 Hastelloy-C4 0.70 43.70 2 29-200 -328 200 392 /T Ball 142 x 145 x 1.0 5.59 x 5.71 x 0.04 Titanium 0.40 24.97 35 508-160 -256 200 392 Instrument approved for use in Zone 0 (EC) /Ex/Z0 Cylinder 97 x 145 x 1.0 3.82 x 5.71 x 0.04 Stainless steel 1.4571 (316 Ti) 0.85 53.07 35 508-20 -4 150 302 Cylinder 97 x 145 x 0.6 3.82 x 5.71 x 0.02 Stainless steel 1.4571 (316 Ti) 0.70 43.70 22 319-20 -4 150 302 Ball 142 x 145 x 0.7 5.59 x 5.71 x 0.03 Stainless steel 1.4571 (316 Ti) 0.40 24.97 22 319-20 -4 150 302 Ball 142 x 145 x 1.0 5.59 x 5.71 x 0.04 Stainless steel 1.4571 (316 Ti) 0.50 31.21 35 508-20 -4 150 302 Ball 97 x 145 x 1.0 3.82 x 5.71 x 0.04 Titanium 0.45 28.09 30 435-20 -4 150 302 Ball 142 x 145 x 1.0 5.59 x 5.71 x 0.04 Titanium 0.40 24.97 30 435-20 -4 150 302 Instruments approved as part of an overfill protection system /F/Ex/Z0 Cylinder 97 x 145 x 1.0 3.82 x 5.71 x 0.04 Stainless steel 1.4571 (316 Ti) 1.00 62.43 28 406-20 -4 75 167 Ball 142 x 145 x 1.0 5.59 x 5.71 x 0.04 Stainless steel 1.4571 (316 Ti) 0.65 40.58 28 406-20 -4 75 167 Cylinder 97 x 145 x 1.0 3.82 x 5.71 x 0.04 Titanium 0.60 37.46 23 334-20 -4 75 167 Ball 142 x 145 x 1.0 5.59 x 5.71 x 0.04 Titanium 0.50 31.21 23 334-20 -4 75 167 /F/WB Cylinder 97 x 145 x 1.0 3.82 x 5.71 x 0.04 Stainless steel 1.4571 (316 Ti) 1.00 62.43 3 44-20 -4 60 140 Ball 142 x 145 x 1.0 5.59 x 5.71 x 0.04 Stainless steel 1.4571 (316 Ti) 0.65 40.58 3 44-20 -4 60 140 Cylinder 97 x 145 x 1.0 3.82 x 5.71 x 0.04 Titanium 0.60 37.46 3 44-20 -4 60 140 Ball 142 x 145 x 1.0 5.59 x 5.71 x 0.04 Titanium 0.50 31.21 3 44-20 -4 60 140 /F/WN Cylinder 97 x 145 x 1.0 3.82 x 5.71 x 0.04 Stainless steel 1.4571 (316 Ti) 1.00 62.43 3 29-20 -4 200 392 Ball 142 x 145 x 1.0 5.59 x 5.71 x 0.04 Stainless steel 1.4571 (316 Ti) 0.65 40.58 3 44-20 -4 200 392 Cylinder 140 x 170 x 1.0 5.51 x 6.69 x 0.04 Hastelloy-C4 0.70 43.70 2 29-20 -4 200 392 Cylinder 97 x 145 x 1.0 3.82 x 5.71 x 0.04 Titanium 0.60 37.46 3 29-20 -4 200 392 Ball 142 x 145 x 1.0 5.59 x 5.71 x 0.04 Titanium 0.50 31.21 3 44-20 -4 200 392 Product Overview Vibration Continuous, non-contact Switches Ultrasonic Radar Ultrasonic Buoyancy Capacitance Continuous, contact Ultrasonic Buoyancy TDR Important! The specified max. allowable operating pressure applies to 20 C or 68 F only! Float test pressure = 1.3 times the max. allowable operating pressure. Hazardous-duty units = 1.5 times the max. allowable operating pressure. 37

Instrument versions Version /RR /R* /R-PVC BM 24 R-PP (not approved) (not approved) Flange Stainless steel 1.4571 Screw connection Stainless steel 1.4571 Stainless steel 1.4571 (316 Ti) Stainless steel 1.4571 (316 Ti) (316 Ti) (316 Ti) with PVC face with PP face Guide tube Stainless steel 1.4571 Stainless steel 1.4571 Stainless steel 1.4571 Stainless steel 1.4571 material (316 Ti) (316 Ti) (316 Ti) / with PVC tube (316 Ti) / with PP tube Guide tube dimensions mm 21.30 x 2.00 21.30 x 2.00 20.00 x 1.50 / 25.00 x 1.80 20.00 x 1.50 / 25.00 x 1,80 inches 0.84 x 0.08 0.84 x 0.08 0.79 x 0.06 / 0.98 x 0.07 0.79 x 0.06 / 0.98 x 0.07 Weight ** approx. kg 4 3 5 5 approx. lb 8.8 6.6 11 11 Version /R-PTFE /R-Titan /R-Hastelloy-C4 (not approved) Flange Stainless steel 1.4571 Stainless steel 1.4571 Stainless steel 1.4571 (316 Ti) (316 Ti) (316 Ti) with PTFE face titanium plated Hastelloy-C4 plated Guide tube material Stainless steel 1.4571 Titanium Hastelloy-C4 (316 Ti) / with PTFE tube Guide tube dimensions mm 21.30 x 2.00 /25.00 x 2.00 21.30 x 2.00 25.00 x 1.60 inches 0.84 x 0.08 / 0.98 x 0.08 0.84 x 0.08 0.98 x 0.06 Weight ** approx. kg 5 4.5 4.5 approx. lb 11 9.9 9.9 ** Only for standard instruments and those approved for use in Zone 0 ** Weight = Instrument with 1 m (3.3 ft) guide tube length plus 1 kg (2.2 lb) for every additional meter (3.3 ft) tube length Guide tube test pressure = 1.5 times the max. allowable operating pressure at 20 C (68 F). 38

Dimensions in mm (inches) /RR Flange version /R Version with screw connection /T For ships tank with test device Product Overview 1 Cap 2 Test knob 3 Wire 4 Reed contact 5 Float 6 Rod magnet 7 Sleeve Vibration Continuous, non-contact Switches Ultrasonic Radar Ultrasonic Buoyancy Capacitance Continuous, contact Ultrasonic Buoyancy TDR 39

Approvals Application Instrument version Certification mark With explosion protection / / K.. / Ex / Z0 PTB No. Ex-85 / 2156 X In stationary storage tanks for flammable water pollutants in classes AI, AII and B (excl. CS 2 ), float and guide tube in Zone 0 Overfill protection with explosion protection / / K..- F / Ex / Z0 PTB No. III B / E 26390 F In stationary storage tanks for flammable, water pollutants in classes AI, AII and B (excl. CS 2 ), float and guide tube in Zone 0 Overfill protection without explosion protection / / K..- F / WB PTB No. III B / S 1806 F In stationary tanks [max. operating pressure 3 bar (43.5 psig)] for flammable water pollutants in class AIII Overfill protection without explosion protection / / K..- F / WN DIBT Approval Notice Z-65.11-223 In stationary tanks [max. operating pressure 3 bar (43.5 psig)] for non-flammable water pollutants PTB = Physikalisch-Technische Bundesanstalt Type code Instrument Liquid level switch Material RR Stainless steel R Stainless steel, screw connection R-PVC PVC version R-PP PP version R-PTFE PTFE version R-Titan Titanium version R-Hastelloy-C4 Hastelloy-C4 version Number of contacts K1 1 contact K4 4 contacts K2 2 contacts K5 5 conatcts K3 3 contacts K6 6 contacts Type of contact W monostable Bi bistable (not approved as part of an overfill protection system) Range of application N normal range (not for approved instruments) Ex/Z0 electrical equipment for use in hazardous areas F/Ex/Z0 hazardous-area electrical equipment as part of an overfill protection system for flammable water pollutants, classes AI, AII, B F/WB part of an overfill protection system for flammable, water pollutants, class AIII F/WN part of an overfill protection system for non-flammable, water pollutants Special versions T Instrument with test device for non-hazardous areas and for ships tanks TS Interface detection (when used in Zone 0, the max. guide tube length is dependent on the float weight). Not approved as part of an overfill protection system. 40