BERMA Waterworks Combination Air Valve Model C7 BERMA C7 is a high quality combination air valve for a variety of water networks and operating conditions. It evacuates air during pipeline filling, allows efficient release of air pockets from pressurized pipes, and enables large volume air intake in the event of network draining. With its advanced aerodynamic design, double orifice and anti-slam / slow closing device, this valve provides excellent protection again air accumulation, vacuum formation and pressure surges, with improved sealing in low pressure conditions. The valve minimizes water spraying during air release. Typical Applications Pumping stations and deep well pumps Air relief, surge protection and vacuum prevention. Pipelines Protection against air accumulation and vacuum formation at elevations, slope change points and at road / river crossings. Water networks Protection against vacuum formation, surge and water hammers at points likely to experience water column separation. Features & Benefits Straight flow body with nominal (equal) inlet and outlet size igher than usual flow rates. Aerodynamic full-body kinetic shield Prevents premature closing without disturbing air intake or discharge. ynamic sealing Prevents leakage under low pressure conditions (.1 bar). Minimizes water spraying during air release Innovative 2-step function, automatic orifice (Patent Pending). Three optional outlets (sideways, downwards, circular-surround mushroom configuration) that can swivel 36 Easy to install in a variety of site conditions. Compact, simple, robust and reliable structure with fully corrosion-resistant parts Lower maintenance and increased life span. esigned in compliance with WRAS, AS4596, EN-174 / 4, AWWA C-512 standards and water service standards. Factory approval and Quality Control Performance and specification tested and measured with specialized test bench, including vacuum pressure conditions. Additional Features Built in Adjustable Surge Protection (anti-slam) Smoother operation, preventing damage to the valve and the system. The conditions for partially closing the kinetic orifice (the switching value ) can be adjusted according to the specific system requirements (C7-SP, C7-AS). Inflow Prevention Prevents intake of atmospheric air in cases where this could lead to damaged pumps, required re-priming, or disruption of siphons; prevents intake of flood water or contaminated water into potable water networks (C7-IP). Two service ports for drainage and pressure gauge. rainage Valve. Insect Screen.
BERMA Waterworks Model C7 Principles of Operation Pipeline Filling: uring the filling process of a pipeline, high air flow is forced out through the kinetic orifice of the air valve. Once water enters the valve s chamber, the float buoyed upwards causes the kinetic orifice to close. The unique aerodynamic structure of the valve body and float ensures that the float cannot be closed before water reaches the valve. Pressurized Operation: uring pressurized operation of the pipeline, air accumulates in the upper part of the air valve chamber, causing the float to gravitate downwards. The automatic orifice opens in a two-step function, forming an air gap between the water level and the air release orifice and then releasing the accumulated air, while minimizing the spray effect. Once the air is discharged, the water level and float rise, causing the automatic orifice to close. Surge Protection (anti-slam): In the event of a pressure surge, the surge protection disc rises, partially closing the valve s orifice. The approaching water column decelerates due to the resistance of the rising air pressure in the valve. This is typically used on pump stations and at specific pipeline locations to minimise pressure surges during pipe filling or power failure conditions at the pump station. Pipeline raining: When a pipeline is drained, a negative differential pressure is created causing atmospheric air to push the float down. The kinetic orifice stays open and air enters the valve chamber, preventing vacuum formation in the pipe. Inflow Prevention: The inflow prevention mechanism is a Normally Closed check disc mounted on the top of the valve s orifice preventing flow of atmospheric air into the valve. Typically used to prime pump suction lines or on pipelines requiring only air discharge and no air re-entry such as siphons. Valve Selection Body Material: Standard Cast ductile iron Optional Stainless Steel, Bronze Inlet sizes: Coating Fusion Bonded Epoxy, Blue N5, N8, N1, N15, N2,,,, Connections: Threaded Female BSPT only for N5 () Flanged ISO PN16 / 25 / 4 Outlets configuration : Sideways N5-8 (2-3") BSP threaded, N1-2 (4-8") Victaulic / Grooved connection. ownwards Mushroom Additional features: Surge Protection (C7-SP, C7-AS) Inflow Prevention (C7-IP) Operational ata Pressure rating: ISO PN16, PN25, PN4 Operating pressure range:.1-16 bar,.1-25 bar,.1-4 bar Operating temperature: Water up to 6 C Orifice Specifications N Size Kinetic Surge Protetion Inch Ad [mm²] Ad [mm²] N5 2 5 1,963 5 x 4 79 N8 3 8 5,27 8 x 4 21 N1 4 1 7,854 1 x 4 314 N15 6 15 17,671 15 x 4 77 N2 8 2 31,416 2 x 4 1,257 N Size Inch PN 16 Automatic PN 25 PN 4 N5 2 1.1.6.4 N8 3 2.5 1.5 1. N1 4 3.1 2. 1.3 N15 6 9.1 5.7 3.5 N2 8 22.1 14.5 8.
BERMA Waterworks Model C7 Air Flow Performance Charts Air Relief and Intake (Pipeline Filling, raining and Vacuum Conditions).4.4.3 own outlet.3 own outlet.2.1 -.1 -.2 -.3.2.1 -.1 -.2 -.3 -.4-4, -3, -2, -1, 1, 2, 3, 4, -.4-1, -7,5-5, -2,5 2,5 5, 7,5 1,.4.4.3 Mushroom Outlet.3 Mushroom Outlet.2.1 -.1 -.2 -.3.2.1 -.1 -.2 -.3 -.4-4, -3, -2, -1, 1, 2, 3, 4, 5, -.4-15, -1, -5, 5, 1, 15, 2, Air Relief with Surge Protection.4.4.4.4.3 own outlet.2.2.1.1.3.3 Mushroom outlet.2.2.1.1.3 5 1 15 3, 6, 5 1 15 3, 6, Air relief and intake charts are based on actual measurements, made during 214-215 in Bermad Air Flow test bench, according to EN-174/4 standard and certified to AS-4598 (28) standard. For Side outlet air flow performance, please consult with BERMA. Use Bermad Air software (www.bermad-air.com) for optimized Sizing & Positioning of Air Valves.
BERMA Waterworks Model C7 Air Release (Pressurized Operation) 4 3 2 1 4 8 12 16 2 For higher automatic air release capacity, Please consult wit BERMA. Cutaway Eye Bolt ownwards Outlet ynamic Seal Adjustable Surge Protection (only C7-AS) Pre-set 2nd stage flow (only C7-AS) Auto Orifice Auto Orifice isc Insect Screen (Optional) Top Plate Surge Protection isc (only C7-SP) ynamic Seal Guiding Ribs Without Surge Protection (C7) Auto Orifice Rod Float Flanged ISO PN16 / 25 / 4 With Inflow Prevention (C7-IP)
BERMA Waterworks Model C7 imensions & s Size Side Outlet own Outlet Mushroom Outlet N Inch Connection 5 Threaded 181 284 8 225 282 8 175 268 8 5 Flanged 187 32 1 232 3 11 175 286 1 8 Flanged 245 356 17 311 356 17 229 327 16 1 Flanged 283 41 22 371 41 23 272 38 22 15 Flanged 368 571 5 493 569 53 381 572 51 2 Flanged 475 77 121 661 77 125 56 79 12 Parts List and Materials escription Material Standards / Remarks 1 Body-Flange / Threaded Cast, uctile Iron ASTM A536 GR. 65-45-12 (EN-GJS 45-1 IN EN1563) 2 Outlet side, down, mushroom Cast, uctile Iron ASTM A536 GR. 65-45-12 (EN-GJS 45-1 IN EN1563) 3 Top Plate Seal EPM For rinking Water 4 Surge Protection isc Polypropylene For rinking Water, Only C7-SP 5 Surge Protection isc Seal EPM For rinking Water, Only C7-SP 6 Surge Protection Adjustable Shutter Stainless Steel AISI 34 (only C7-AS) 7 Auto Orifice isc Polypropylene For rinking Water 8 Float Polypropylene For rinking Water 9 Top Plate Stainless Steel ASTM A744 Gr. CF8M 1 Insect Screen Stainless Steel AISI 34 (Optional) 11 Check isk (Inflow Prevention) Stainless Steel + EPM Only C7-IP 12 Cover O-Ring EPM For rinking Water 13 Auto Orifice Stainless Steel AISI 34 14 Auto Orifice O-Ring EPM For rinking Water 15 Auto Orifice Plug Glass Reinforced Nylon For rinking Water 16 Auto Orifice Plug O-Ring EPM For rinking Water 17 Auto Orifice Seal EPM For rinking Water 18 Auto Orifice Rod Reinforced Polyamide For rinking Water 19 Snap Ring Reinforced Polyamide For rinking Water 2 Cover Screw Stainless Steel AISI 34 21 Stud Stainless Steel AISI 34 22 Nut Stainless Steel AISI 34 23 Washer Stainless Steel AISI 34 24 Eye Bolt Stainless Steel AISI 34 info@bermad.com www.bermad.com Copyright 27-212 Bermad CS Ltd. All Rights Reserved. The information contained in this document is subject to change without notice. BERMA shall not be liable for any errors contained herein. PCAWE11-C7 May 216