MF2M Monnier Miniature Compressed Air Filter

Similar documents
ML3M Monnier Miniature Compressed Air Lubricator

IX1 Spirax-Monnier International Compressed Air Filter Installation and Maintenance Instructions

Dri-Line Mk3 Monnier Compressed Air Drain Trap

MPC1M, MPC2M and MPC2AM Monnier High Efficiency Compressed Air Filter / Regulators

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

DF1 and DF2 Diffusers

TA10A and TA10P Steam Tracing Temperature Control Valves Installation and Maintenance Instructions

TSS21 Sealed Thermostatic Steam Tracer Trap

Fig 12, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Dial Adjustment)

Fig 1, Fig 12, Fig 13, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

TP1 and TP2 Temporary Cone Shaped Strainers

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Knob Adjustment)

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

PV4 and PV6 Piston Valves

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

DCV10 Stainless Steel Disc Check Valve for use with Condensate Pumps

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

DCV1, DCV3 and DCV3LT Disc Check Valves Installation and Maintenance Instructions

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

CP10 Sensor Installation and Maintenance Instructions

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators Installation and Maintenance Instructions

FV Flash Vessel Installation and Maintenance Instructions

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

IFTGS14 Ball Float Steam Trap ½" and ¾" with Integral Spiratec Sensor

AVC32 Carbon Steel Air Vent for Steam Systems

DCV6 Disc Check Valve

CVS10 Sanitary Check Valves

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

FTGS14 Ball Float Steam Trap DN15 (½") to DN25 (1")

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

AE14 Automatic Air Vents for Liquid Systems Installation and Maintenance Instructions

AVM7 Stainless Steel Thermostatic Air Vent

Fig 3, 7, 33, 34, 34HP, 36, 36HP, 37, 3616 and Fig 3716 Flanged Strainers

Manual Actuated Boiler Blowdown Valves

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

SRV66 Sanitary Pressure Reducing Valve

Airodyn, BRair and BRoil Compressed Air Drain Traps

APT14, APT14HC and APT14SHC Spares 2

Spirax Compact FREME Flash Recovery Energy Management Equipment

SA Control Valve types: BM, BMF, BX, SB, NS, KA, KB, KC (Normally open) BMRA, BMFRA, BXRA, SBRA, NSRA, KX, KY (Normally closed)

BTM7, BTS7 and BTS7.1 Stainless Steel Thermostatic Clean Steam Traps

M33F ISO, M33S ISO and M33V ISO Ball Valves Installation and Maintenance Instructions

BCV31 DN40 - Blowdown Control Valve

CA44, CA44S, CA46 and CA46S Air and Gas Traps

TW Temperature Control Valve

AE30 Automatic Air Eliminators / Air and Gas Vents for Liquid Systems

S and SF Inverted Bucket Steam Traps

CS10-1 Stainless Steel Clean Steam Separator

PC10HP Pipeline Connector (ASME 600)

BCV31 DN20 - Blowdown Control Valve

Type 130 and HL10 'Safeguard High Limit Control' Installation and Maintenance Instructions

SRV2S Pressure Reducing Valve

Fig 7, 33, 33.1, 34, 34HP, 36, 36HP, 37, 3616 and Fig 3716 Flanged Strainers Installation and Maintenance Instructions

BPT13 Balanced Pressure Thermostatic Steam Traps

MFP14-PPU (Vented) Automatic Packaged Pump Units

M10HTi ISO Tobacco Ball Valve Screwed, SW, BW and Flanged versions

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

M70i ISO and M80i ISO Stainless Steel Ball Valves for Sanitary Systems Installation and Maintenance Instructions

TDC46M, TDS46M and UTDS46M Thermodynamic Steam Traps with Maintainable Seat Installation and Maintenance Instructions

BT6-B Sanitary Balanced Pressure Thermostatic Steam Trap

BRV71 and BRV73 Pressure Reducing Valves

TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators

Vane Flow Switches Colima FLU Series

CA10S, CA14 and CA14S Air and Gas Traps

TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats Installation and Maintenance Instructions

FT53, IFT53, FT54, IFT54, FT57 and IFT57 Ball Float Steam Traps - DIN

Spirax SafeBloc TM DBB3 Double Block and Bleed Bellows Sealed Stop Valve. 1. Safety information. 2. General product information. 3.

QuickHeat TM Packaged Heat Exchanger Solutions

STERI-TROL Clean Service 'S' Series Two-port Control Valves DN15 (½") to DN100 (4")

M111 Spiraflo Transducer

BDV1 and BDV2 Blowdown / Depressurisation Valves

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

Thermocirc Installation and Maintenance Instructions

AVS32 Stainless Steel Air Vent for Steam Systems Installation and Maintenance Instructions

SCA Series Inverted Bucket Steam Traps

AE50S Automatic Air and Gas Vent for Liquid Systems Installation and Maintenance Instructions

BDV60 Blowdown Vessel Installation and Maintenance Instructions

A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions

CA16 and CA16S-14 Air and Gas trap Installation and Maintenance Instructions

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions

FT16 Ball Float Steam Trap Installation and Maintenance Instructions

Fig 1, Fig 12, Fig 13, Fig 14, Fig 16 and Fig 16L Strainers Installation and Maintenance Instructions

LP31 Level Probe. 1. Safety information. 2. General product information. 3. Installation. 4. Wiring. 5. Maintenance

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

BSA6T and BSA64T Stainless Steel Bellows Sealed Stop Valves Installation and Maintenance Instructions

SRV461S and SRV463S Stainless Steel Direct Acting Pressure Reducing Valves

BTD52L Thermodynamic Steam Trap Installation and Maintenance Instructions

FT43, FT44, FT46 and FT47 Ball Float Steam Traps Installation and Maintenance Instructions

Colima TOR Magnetic Level Switches

PC3000, PC3001 and PC4000, PC4001 Pipeline Connectors

FTC62 and FTS62 Ball Float Steam Traps Installation and Maintenance Instructions

595-K/L and 596-K/L Series Self Operated Valves Installation and Maintenance Instructions

BCVi43 Blowdown Control Valve

TD10, TD52M and TD259 Thermodynamic Steam Traps Installation and Maintenance Instructions

UBP32 Sealed Balanced Pressure Thermostatic Steam Trap for use with PC_ Pipeline Connectors Installation and Maintenance Instructions

LP10-4 Level Probe. 1. Safety information. 2. General product information. 3. Installation. 4. Wiring. 5. Maintenance IM-P402-92

Transcription:

5040050 / 2 IM-P504-02 CH Issue 2 MF2M Monnier Miniature Compressed Air Filter Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation and commissioning 4. Operation 5. Spare parts and Maintenance Copyright 2012 IM-P504-02 CH Issue 2 1 Printed in the USA

1. Safety information Safe operation of these products can only be guaranteed if they are properly installed, commissioned, used and maintained by qualified personnel (see Section 1.11) in compliance with the operating instructions. General installation and safety instructions for pipeline and plant construction, as well as the proper use of tools and safety equipment must also be complied with. 1.1 Intended use Referring to the Installation and Maintenance Instructions, name-plate and Technical Information Sheet, check that the product is suitable for the intended use/application. The products comply with the requirements of the European Pressure Equipment Directive 97/23/EC and fall within the category 'SEP'. It should be noted that products within this category are required by the Directive not to carry the mark. i) The products have been specifically designed for use on compressed air, which is in Group 2 of the above mentioned Pressure Equipment Directive. The products use on other fluids may be possible but, if this is contemplated, Spirax Sarco should be contacted to confirm the suitability of the product for the application being considered. ii) Check material suitability, pressure and temperature and their maximum and minimum values. If the maximum operating limits of the product are lower than those of the system in which it is being fitted, or if malfunction of the product could result in a dangerous overpressure or overtemperature occurrence, ensure a safety device is included in the system to prevent such over-limit situations. iii) Determine the correct installation situation and direction of fluid flow. iv) Spirax Sarco products are not intended to withstand external stresses that may be induced by any system to which they are fitted. It is the responsibility of the installer to consider these stresses and take adequate precautions to minimise them. v) Remove protection covers from all connections and protective film from all nameplates, where appropriate, before installation on steam or other high temperature applications. 1.2 Access Ensure safe access and if necessary a safe working platform (suitably guarded) before attempting to work on the product. Arrange suitable lifting gear if required. 1.3 Lighting Ensure adequate lighting, particularly where detailed or intricate work is required. 1.4 Hazardous liquids or gases in the pipeline Consider what is in the pipeline or what may have been in the pipeline at some previous time. Consider: flammable materials, substances hazardous to health, extremes of temperature. 1.5 Hazardous environment around the product Consider: explosion risk areas, lack of oxygen (e.g. tanks, pits), dangerous gases, extremes of temperature, hot surfaces, fire hazard (e.g. during welding), excessive noise, moving machinery. 2 IM-P504-02 CH Issue 2

1.6 The system Consider the effect on the complete system of the work proposed. Will any proposed action (e.g. closing isolation valves, electrical isolation) put any other part of the system or any personnel at risk? Dangers might include isolation of vents or protective devices or the rendering ineffective of controls or alarms. Ensure isolation valves are turned on and off in a gradual way to avoid system shocks. 1.7 Pressure systems Ensure that any pressure is isolated and safely vented to atmospheric pressure. Consider double isolation (double block and bleed) and the locking or labelling of closed valves. Do not assume that the system has depressurised even when the pressure gauge indicates zero. 1.8 Temperature Allow time for temperature to normalise after isolation to avoid danger of burns. 1.9 Tools and consumables Before starting work ensure that you have suitable tools and /or consumables available. Use only genuine Spirax Sarco replacement parts. 1.10 Protective clothing Consider whether you and/or others in the vicinity require any protective clothing to protect against the hazards of, for example, chemicals, high/low temperature, radiation, noise, falling objects, and dangers to eyes and face. 1.11 Permits to work All work must be carried out or be supervised by a suitably competent person. Installation and operating personnel should be trained in the correct use of the product according to the Installation and Maintenance Instructions. Where a formal 'permit to work' system is in force it must be complied with. Where there is no such system, it is recommended that a responsible person should know what work is going on and, where necessary, arrange to have an assistant whose primary responsibility is safety. Post 'warning notices' if necessary. 1.12 Handling Manual handling of large and/or heavy products may present a risk of injury. Lifting, pushing, pulling, carrying or supporting a load by bodily force can cause injury particularly to the back. You are advised to assess the risks taking into account the task, the individual, the load and the working environment and use the appropriate handling method depending on the circumstances of the work being done. 1.13 Residual hazards In normal use the external surface of the product may be very hot. If used at the maximum permitted operating conditions the surface temperature of some products may reach temperatures of 90 C (194 F). Many products are not self-draining. Take due care when dismantling or removing the product from an installation (refer to 'Maintenance instructions'). IM-P504-02 CH Issue 2 3

1.14 Freezing Provision must be made to protect products which are not self-draining against frost damage in environments where they may be exposed to temperatures below freezing point. 1.15 Disposal Unless otherwise stated in the Installation and Maintenance Instructions, this product is recyclable and no ecological hazard is anticipated with its disposal providing due care is taken. 1.16 Returning products Customers and stockists are reminded that under EC Health, Safety and Environment Law, when returning products to Spirax Sarco they must provide information on any hazards and the precautions to be taken due to contamination residues or mechanical damage which may present a health, safety or environmental risk. This information must be provided in writing including Health and Safety data sheets relating to any substances identified as hazardous or potentially hazardous. 4 IM-P504-02 CH Issue 2

2. General product information 2.1 General description The MF2M Monnier miniature compressed air filter provides high quality compressed air for general purpose pneumatic applications. Principal features: - Compact unit suitable where space is limited and air flow is small. - Multi-bladed whirl disc for improved moisture separation. - Polycarbonate bowl. - Long life 5 µm element. - External black anodised finish. Optional extras: For further technical information regarding the following options see page 6: - Type 3 mounting bracket. - Easy fit stainless steel bowl guard. 2.2 Sizes and pipe connections ¼" screwed BSP (BS 21-Rp). Fig. 1 MF2M Monnier miniature compressed air filter 2.3 Operating limits Maximum Polycarbonate bowl 10 bar g @ 50 C (145 psi g @ 122 F) pressure/temperature Metal bowl 17 bar g @ 80 C (246.5 psi g @ 176 F) 2.4 Materials Part Body Head Element Seals Bowl guard (optional extra) Material Polycarbonate Aluminium Sintered polypropylene Nitrile rubber Stainless steel IM-P504-02 CH Issue 2 5

3. Installation and commissioning Note: Before actioning any installation observe the 'Safety information' in Section 1. Referring to the Installation and Maintenance Instructions, name-plate and Technical Information Sheet, check that the product is suitable for the intended installation. 3.1 Specific product safety information Polycarbonate bowls may be attacked by phosphate ester based fluids, solvents, chemical cleaners, carbon tetrachloride, etc. These and any other substances should not be allowed to come into contact with this component. Certain compressor lubricating oils also contain additives harmful to polycarbonate. Where there is any doubt we recommend, in the interests of personal safety, that bowl guards or metal bowls be fitted. 3.2 General information MF2M Dimensions (approximate) in mm and kg A B C E E1 Weight 10 98 38 25 76 0.155 C Type 3 mounting bracket This is a zinc plated, mild steel angle bracket which can be attached to any flat surface by means of screws or bolts. A Fig. 3 Bowl guard B Dimensions (approximate) in mm and kg A B C D E F 75 50 25 65 13 20 Withdrawal distance: E Without bowl guard E F C D Withdrawal distance: E1With bowl guard A B Bowl guard In the interest of safety Spirax Sarco recommend that a bowl guard should be fitted - see Section 3.1, Specific product safety information. Fig. 4 Fig. 2 6 IM-P504-02 CH Issue 2

3.3 Installation 3.3.1 The unit should be fitted in horizontal pipework with the bowl vertically downwards. 3.3.2 Adequate space should be provided around the unit to allow easy access for routine servicing requirements (see Figure 2 for withdrawal distances). 3.3.3 Connect the unit so that the airflow is in the direction indicated by the arrow on the body. 3.3.4 The unit should be installed as close as possible to the equipment it is serving. 3.3.5 The body has two R" ports, one of which is available for fitting a pressure gauge to register the secondary pressure. In the event that a pressure gauge is not fitted, this port should be blanked off with the blank plug provided. Ensure that the range of the pressure gauge corresponds with that of the main control spring as indicated on the unit. The second port should not be used for any purpose and is sealed with a factory fitted plug which should not be removed. 3.3.6 Do not overload the filter cartridge (see Section 4 - Operating principals) or there will be a reduction in its efficiency and /or life. On heavily contaminated systems, it is advisable to fit a conventional pneumatic filter (Monnier International or Miniature) immediately in front of the unit for maximum efficiency and life cycle. 3.3.7 The polycarbonate bowl may be fitted with a bowl guard. IM-P504-02 CH Issue 2 7

4. Operation 4.1 Principle of operation Monnier air line filters are built to ensure solid and liquid contaminants are removed from compressed air. All Monnier filters are engineered with the exclusive Whirl-Away design which creates high centrifugal force with low pressure drop. The whirling action forces all liquids and solids against the bowl wall causing them to run down below the quiet-zone baffle where they can be drained out. The air then flows through the element where the smaller particles are removed and the filtered air passes downstream. The leak proof drain valve has an o-ring seal that can be opened and closed without tools. 4.2 Performance selection (with primary pressure 10 bar) For any specified primary filtration pressure, there is a maximum recommended air flowrate. Keeping within this, will ensure that the element performance maintains the stated high efficiency levels, particularly for the removal of oil and water contaminants. 4.3 Capacities 0.7 Air flow scfm 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 10 0.6 9 8 Pressure drop bar 0.5 0.4 0.3 1.6 bar g (23 psi g) 2.5 bar g (32 psi g) 4 bar g (58 psi g) 6.3 bar g (91 psi g) 10 bar g (145 psi g) 7 6 5 4 Pressure drop psi 0.2 3 2 0.1 1 0 0 2 4 6 8 10 12 14 Air flow dm³/s 0 8 IM-P504-02 CH Issue 2

Fig. 5 Operation IM-P504-02 CH Issue 2 9

5. Spare parts and maintenance 5.1 Spare parts The spare parts available are detailed below. No other parts are supplied as spares. Available spares Bowl assembly Element set 5 micron (packet of 3) Bowl guard assembly (optional extra) Note: In the interests of safety Spirax Sarco recommend that a bowl guard (an optional extra) should be fitted to polycarbonate bowls. How to order spares Always order spares by using the desciption given in the column headed 'Available spares' and state the size and type of unit. Example: 1-1 - Element set (5 microns) for a ¼" MF2M Monnier miniature compressed air filter. 5.2 Maintenance To service the filter (no tools required): - Isolate the main air supply. - Remove the bowl guard if fitted. - Release the pressure by opening the manual drain or gently unscrewing the bowl (A) until the pressure relieves. - Remove the bowl (A) and unscrew the element retaining nut and withdraw the filter assembly (C). - Clean the bowl (A) using soap and water only (do not use solvents or proprietary cleaners) and wipe dry with a lint free cloth. - Reassemble in reverse order using a new element (C), ensuring that the element 'O' ring (B) is fitted. - The bowl should be firmly hand tightened. Retaining nut A, B B, C D, E B C A Manual drain D E Fig. 6 Spare parts 10 IM-P504-02 CH Issue 2

IM-P504-02 CH Issue 2 11

12 IM-P504-02 CH Issue 2