POLYURETHANE SPRAY FOAM REFILL SYSTEM QUICK START GUIDE

Similar documents
Refill Systems Edition. Manual. The Dow Chemical Company

Installation of Your SprayMaster System

accidents which arise due to non-observance of these instructions and the safety information herein.

Chemical Injection Technologies Installation/Service Bulletin

OPERATION MANUAL NTF-60 Plus

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

OPERATION MANUAL NTF-15

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

KJ4000 Operating Instructions & Parts Manual NSN

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

200 PSI HIGH-FLOW AIR SOURCE KIT

Interface Devices, Inc. Hydraulic Mini Mule

XpressFill XF2500 Counter Pressure Filler. Operating Instructions

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

User Instruction Manual

Instruction Manual Updated 7/26/2011 Ver. 2.2

MODEL 840 AIR HYDRAULIC PUMP INSTRUCTION

Rejuvenation Instructions

OPERATING AND MAINTENANCE MANUAL

FisherPak Instructions

200 PSI FAST-FILL AIR SOURCE KIT

Instruction Manual - Diaframless TM Ejector Chlorine, Sulfur Dioxide and Ammonia

MODEL 1410 OWNER S MANUAL

Instruction Manual Recovery Station

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Model PSI Compressor with 3-Gallon Air Tank 12VDC

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

XpressFill XF4500 Counter Pressure Filler. Operating Instructions

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

Instruction & Parts Manual

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7

A/C SOLVENT FLUSH (For use with CPS SUPER FLUSH SOLVENT) TO BE OPERATED BY QUALIFIED PERSONNEL ONLY OPERATION MANUAL

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

Steel Spring Driven Reel Instruction Manual

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

LARGE DRY CHEMICAL, TWIN-AGENT, AFFF, HALON 1211, AND AQUASONIC (NITROGEN-OPERATED SYSTEMS) Pressure Regulator Test Manual

30T A/Manual Hydraulic Shop Press

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

2 GAL AIR COMPRESSOR OPERATOR S MANUAL 1/3HP/2-GALLON IMPORTANT: READ THIS OPERATOR S MANUAL BEFORE USING

1 DRIVE INDUSTRIAL IMPACT WRENCH

Spray Gun 134-A. 1 Liter High- Pressure Gel Coat. Usage Instructions & Parts List

INFLATOR TDUX-IT-16 AND GAS CYLINDER E

SINORIX Valve Reconditioning

Rev. B. Operating Instructions

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

Budget Range Operators Handbook

TactAir PCP Fill Kit/Adapter. Operation Manual

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

ACCESSORY KIT INSTALLATION INSTRUCTIONS

INSTALLATION and OPERATION INSTRUCTIONS

! WARNING! IMPORTANT HPA AIR TANK SAFETY INSTRUCTION AND GUIDELINES ! WARNING! IMPORTANT SAFETY INSTRUCTION AND GUIDELINES

XpressFill XF4500C Counter Pressure Can Filler. Operating Instructions

MANUAL BE SERIES Test Benches

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Napa Technology Trouble Shooting. For Premier & Premier PLUS Models

Auto EVAP Quick Start Guide

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

PRESSURISED PAINT CONTAINER

Operation Manual Guillotine Cutter RC-5

AIR/OVER HYDRAULIC JACK 20 TON

MB-SP Series Solvent Purification System

NITROGEN INFLATION SYSTEM NG-4, NG-6, NG-12, NG-18

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

NTF-230 OPERATION MANUAL

GAS BBQ 4 burner. instructions for. model no: BBQ10

ACCESSORY KIT INSTALLATION MANUAL

GEN-1e CO2 Generator OVERVIEW INSTALLATION PROPANE GENERATORS ONLY NATURAL GAS GENERATORS ONLY

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

TECHNICAL DATA. than the water inlet pressure to the concentrate

Installation Instructions and valve Maintenance Rev. 0 of 21/09/15

G92 Series BASOTROL Automatic Pilot Gas Valve

Freedom8 ShoeBox Compressor Manual

Pressure Regulators. Instructions for Use

ATD /8 x 50 Retractable Air Hose Reel Owner s Manual

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

Concentrate Distribution System (Stand Mounted) A-CDS-70-X & A-CDS-TANK-X-ST Industrial Drive, Orlinda, TN 37141

Safety instructions and operating manual

Instruction Manual. B&O WITH SLOPE BACK TENDER Live Steam

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

Injection Systems INSTALLATION AND OPERATING GUIDE HI FLO VERTICAL TANK SYSTEMS

RD(H)20/25 Pressure-Reducing Regulator User Manual

1. CONDITIONS FOR USE 2. SAFETY

TL-12 FLUSH TANK. Manual Ref. # MN-??? Polyurethane Machinery Corp. REVISION 1.0

INSTRUCTION MANUAL FOR EBA MINUTE SELF-CONTAINED SELF RESCUER (SCSR) Manual Number: NH13747 Revision: A, ECN 2384 September 7, 2001

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

Hotspotter. Model WB-100 Professional Series. Assembly, Testing & Operating Instructions. Safety Information:

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

Operator: Save these instructions for future use!

Before using or working with the Grab n Go Heliox system, please read and understand the usage and safety instructions provided in this booklet.

RK-IR Sample Draw Aspirator Adapter Operator s Manual

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

Assembly and Installation Procedures

Transcription:

POLYURETHANE SPRAY FOAM REFILL SYSTEM QUICK START GUIDE

SYSTEM DESCRIPTION The Touch n Seal Refill System is a spray polyurethane foam dispensing system for large volume foam users. The system consists of A and B chemical tanks, in-line chemical filters, cleanable on/off valves, a high pressure regulator, nitrogen hoses, chemical dispensing hoses, nitrogen pressure control gauge and a foam applicator. The Touch n Seal Refill System is designed for ease-of-use. The following Quick Start Manual instructions are prepared for the experienced system user and are not meant to cover all operational, system or trouble shooting details. Unit Size 17 gal 64.34 L 60 gal 227.12 L 120 gal 454.25 L Chemical Wt (lb/kg) 150/68.04 500/226.80 1,125/510. Empty Tank Wt w/valves (lb/kg) 65/29.48 172/78.02 314/142.4 Gross Wt Filled (lb/kg) 215/97.52 672/304.81 1,439/652. Cylinder Dimensions in/cm (FOR SHIPPING) Width 15/38.1 24/60.96 30/76.20 Depth 15/38.1 24/60.96 30/76.20 Height 34/86.36 46/116.84 57/144.7 If you have additional questions, please contact your Convenience Products Sales Representative or Technical Support at (800) 325-6180. INSTALLATION, SET UP, CALIBRATION AND OPERATION NOTE: Dry nitrogen is used for pressurizing the refill system and is not supplied. It may be obtained for a nominal rental charge from your local welding supplier. Order standard size (industrial grade) cylinder with CGA 580 nitrogen fitting. Parts are referenced by name and alpha designation A-O on System Diagram. SET UP (Steps 1 14) 1. Position the A tank to the left and the B tank to the right. 2. Place a nitrogen cylinder behind and between the A and B tanks. Secure the nitrogen cylinder to prevent it from falling (Photo A). 3. Install nitrogen regulator onto nitrogen tank. Hand tighten and snug firmly using an adjustable wrench. Be careful not to strip the brass fitting by over tightening (Photo B). 4. Verify that the pressure control valves are backed out, by turning counterclockwise to Photo A eliminate nitrogen flow. 5. Remove the thread protectors on the bottom of the nitrogen regulator and connect the first of two nitrogen hoses to the left fitting on the nitrogen regulator assembly. Snug firmly with an adjustable wrench. 6. Locate the nitrogen intake valve of the A tank (photo C). Verify that the valve is closed. The handle should be perpendicular to the valve. Loosen and remove the nitrogen intake cap on the A tank (Photo C) and store in the canvas bag on top of the tank. 7. Connect the other end of the nitrogen hose labeled A to the nitrogen intake valve of the A tank (photo D). Snug firmly with an adjustable wrench. NITROGEN INTAKE CAP PRESSURE RELIEF VALVE CHEMICAL VALVE HANDLE (CLOSED) CHEMICAL VALVE ASSEMBLY NITROGEN TANK HOSE Photo B A CHEMICAL PRESSURE GAUGE NITROGEN TANK PRESSURE GAUGE PRESSURE CONTROL VALVES B CHEMICAL PRESSURE GAUGE NITROGEN TANK HOSE 8. Connect the second nitrogen hose to the right fitting of the nitrogen regulator (photo B). Snug firmly with an adjustable wrench. Follow steps 6 7 to attach the remaining 10' unlabeled black nitrogen hose to the intake valve of the B tank. 9. Verify that the chemical tank valves are closed (photo C). The handle should be perpendicular to the valve. Remove the chemical valve plug (photo C) from each of the A and B tanks and place one plug in each of the canvas bags provided (photo C). Each plug must be lubricated and reinstalled prior to empty tank return. 10. Remove filter assembly from the canvas bag (photo E) attached to the tank. Connect a filter assembly to each chemical tank valve with the filter assembly arrows pointing away from the tanks (photo D). The arrows represent the direction of the chemical flow. Tighten the filter assemblies with the adjustable wrench. 11. Connect the on/off valves tank-to-hose (with the swivel ends) to the filter ON/OFF VALVE TANK-TO-HOSE NITROGEN HOSE (CLOSED) FILTER ASSEMBLY NITROGEN INTAKE VALVE ASSEMBLY (CLOSED) NITROGEN INTAKE VALVE ASSEMBLY Photo C CHEMICAL VALVE PLUG Photo D CHEMICAL VALVE HANDLE (CLOSED)

assemblies of each tank. Tighten the FILTER ASSEMBLY connections with an adjustable wrench (photo D). 12. Uncoil the hose sets. (If desired, you may connect two 30 hose sets together, using the provided connectors, to make a 60 hose set by connecting the A hose of one set to the A hose of the second set. Follow the same procedure for the connecting the two B hoses together.) Connect the A-side chemical hose (the one with the warning label) to the on/off valve tank-to-hose on tank A and the other chemical hose to the on/off valve tank-to-hose on tank B (photo D). Tighten both connections with an adjustable wrench. Photo E 13. Connect an on/off valve hose-to-applicator to the other end of each chemical hose. Verify that the arrows on each on/off valve hose-to-applicator point away from the A and B chemical tanks. (Arrow indicates chemical flow.) Tighten each connection with two adjustable wrenches (Photo F). 14. Connect the foam applicator hose to the on/off valve hose-to-applicator of each chemical hose; A labeled chemical hose to A labeled (red striped) foam applicator hose, the unlabeled hose to the unlabeled (unstriped) foam applicator hose. Tighten each connection using two adjustable FOAM APPLICATOR ON/OFF VALVES HOSE-TO-APPLICATOR wrenches (photo F). Photo F CHEMICAL HOSES PRESSURIZATION 15. Engage the safety on the foam applicator (photo G). 16. Verify that the pressure control valves on the regulator are backed out to eliminate nitrogen flow. 17. Open the nitrogen bottle valve by turning the knob on top of the cylinder counterclockwise. If a hissing sound occurs, further tighten the nitrogen regulator assembly pressure control valve with an adjustable wrench. 18. Verify the nitrogen cylinder pressure using the center gauge of the nitrogen regulator assembly. Replace nitrogen tank when pressure falls below 500 psi. 19. Slowly turn the left regulator pressure control valve clockwise until the proper pressure setting is obtained (refer to Table A). If a hissing sound occurs, further tighten the nitrogen hose set connection to the nitrogen regulator assembly and/ or the nitrogen intake valve connection on the A tank using an adjustable wrench. If the left gauge fails to indicate a pressure setting, contact your Convenience Products Sales Representative. 20. Slowly turn the right regulator pressure control valve clockwise until the proper pressure setting is obtained (refer to Table A). If a hissing sound occurs, further tighten the nitrogen hose set connection to the nitrogen regulator assembly and/or the nitrogen intake valve connection on the B tank using an adjustable wrench. If the right gauge fails to indicate a pressure setting, contact your Convenience Products Sales Representative. BARREL SAFETY ON Photo G TRIGGER SAFETY TRIGGER SAFETY OFF 21. Slowly open the nitrogen intake valve of each tank until the handles are parallel with the nitrogen hoses. 22. Slowly turn on the chemical tank valve of each tank until the handles are parallel to the chemical hoses. 23. Slowly turn on the on/off valves tank-to-hose until the handles are parallel to the chemical hoses. 24. Slowly turn on the on/off valves hose-to-applicator until the handles are parallel to the chemical hoses. Verify that ALL chemical and nitrogen valve connections are tight and that no chemical leaks are present. 25. Verify that the foam applicator safety is engaged. 26. IMPORTANT Refer to Safety Precautions for proper personal protection equipment prior to use. REVIEW CALIBRATION INSTRUCTIONS before continuing to step 27. NITROGEN PRESSURE CONTROL GAUGE USE INSTRUCTIONS In the event that either chemical tank pressure exceeds 205 PSI you must reduce the pressure in both chemical tanks to the recommended 170 PSI starting pressure using the Nitrogen Pressure Control Gauge. How to reduce chemical tank pressure: 1. Ensure ALL on/off valves on the chemical tanks and nitrogen supply system are in the off or closed position. 2. Using a 9/16 wrench, disconnect the nitrogen supply line from the nitrogen Part # 4505100048 tank regulator. When disconnecting hose, there may be hissing sound for 1 3 seconds as pressure releases. If you hear continued hissing immediately reconnect hose, close the on/off handles and repeat this step. 3. Connect and firmly tighten the loose nitrogen hose to the male threaded portion of your Nitrogen Pressure Control Gauge. Do not over tighten. 4. With the Nitrogen Pressure Control Gauge in the closed position (handle is perpendicular to gas flow) open the nitrogen valve on your refill chemical tank. If done correctly you should hear no hissing or leaks and the Nitrogen Pressure Control Gauge should indicate the same pressure that your nitrogen regulator was set at previously. 5. Slowly open the on/off valve on your Nitrogen Pressure Control Gauge to release pressure for about 3 seconds at a time, checking progress and repeating until the gauge reaches the desired 170 PSI. 6. Upon reaching 170 PSI close the nitrogen pressure intake valve on your chemical tank and release the residual pressure in your line by opening your Nitrogen Pressure Control Gauge. If this has been done correctly, the tank in question should be reset to 170 PSI and no leaking sounds should be heard. 7. Remove the Nitrogen Pressure Control Gauge and reconnect your nitrogen line back to the corresponding side of your nitrogen tank regulator. 8. Repeat steps 1 7 for the other chemical tank so that both the A & B chemical tanks have been reset to the base pressure of 170 PSI. 9. Important! Before turning the nitrogen supply back on, turn regulator adjustment knobs completely counterclockwise (off) so that the nitrogen output pressure will be 0 PSI. 10. You can begin the start-up process and Calibration Procedure as if it were a new start up. 11. Please contact our technical department or your sales representative with any questions or assistance needed. You can also visit our website at www.touchnseal.com which has several videos and FAQ s.

CALIBRATION INSTRUCTIONS Equipment needed: Scale capable of weighing in grams, paper lunch bags, calibration nozzles, calculator. i. Ensure chemical temperature in tanks and hoses are 70 90 F (21 32 C). ii. Set nitrogen regulator pressures (refer to Table A). iii. Remove nozzle (Photo H) from foam applicator, disengage the foam applicator safety and dispense chemicals in an appropriate waste container to verify proper chemical flow while purging air from the hoses. iv. Weigh and record the weight of each empty bag so that its weight may be deducted from the total weight of the filled paper bags. v. Engage safety and place calibration nozzle on the foam applicator. vi. Holding the two bags together, place the left nozzle tube (side with red striped hose) into the A bag, place the other nozzle in the B bag and disengage safety. Squeeze trigger for six to eight seconds. vii. Engage foam applicator safety. viii. Weigh bags separately. Always divide the weight of bag B into the weight of bag A. Refer to Table A for acceptable chemical ratios. Example A: 208g (weight) 8g (bag weight) = 200g B: 190g (weight) 8g (bag weight) = 182g Ratio: 200 182 = 1.10 ix. After successful calibration, continue to step 27. NOTE: If verification of regulator reading is necessary, install pressure gauges in line with the regulator. Verify both sides. To verify corresponding pressures of tanks, install pressure gauges in line with each tank. Perform this task on the nitrogen inlet valve. Maximum pressure should not exceed 250 psi. Should pressure need to be reduced in a tank, slowly bleed off pressure from the nitrogen intake valve. Never bleed any tank below 120 psi. x. If the ratio is too high, increase the pressure of the B tank, and if the ratio is too low increase the pressure of the A tank. For best results, perform pressure adjustments in 10 psi increments. TABLE A FORMULA Touch n Seal 1.75 pcf FR ICC Touch n Seal 1.75 pcf Standard Photo H PROPER INITIAL PRESSURE SETTING ACCEPTABLE CHEMICAL RATIOS 175 psi 1.08 1.16 175 psi 1.08 1.16 Touch n Seal 2.0 pcf FR 175 psi 1.15 1.25 CALIBRATION NOZZLE, CLEAR CONICAL NOZZLE, CLEAR FAN NOZZLE, YELLOW INJECTION NOZZLE, BLACK 27. Clean any chemical from the front of the foam applicator barrel by wiping with a clean rag (photo I). 28. Place an unused conical or fan nozzle on the barrel of the foam applicator. 29. Disengage the safety on the foam applicator. The Touch n Seal Refill System is now ready for operation. 30. If at anytime during dispensing, foam quality is suspect, remove the nozzle and purge the lines to be sure there are two roughly equal streams of pressurized chemical flowing, then replace with a new nozzle. If nozzle replacement does not solve the problem, contact your sales representative. NOTE: If spraying has stopped more than 30 seconds, foam in the nozzle will begin to cure and clog. System performance will be compromised. Replace the used nozzle with an unused nozzle. Higher temperatures speed curing, while lower temperatures slow curing. Nozzle Replacement Photo I 1. To replace the used nozzle, engage the safety on the foam applicator. 2. Grasp the foam applicator in one hand and the used nozzle in the other. Twist the nozzle and pull it off the barrel. 3. Place an unused nozzle on the barrel of the foam applicator by pushing and twisting the nozzle until firmly locked into place. The Touch N Seal Refill System is ready for operation. FOAM APPLICATOR OPERATION The foam applicator provides greater flow control and minimizes waste when used properly. The following operating instructions ensure maximum efficiency and performance of the foam applicator. 1. IMPORTANT Refer to Safety Precautions for proper personal protection equipment prior to use. 2. VERIFY THAT THE SAFETY IS ENGAGED WHEN THE FOAM APPLICATOR IS NOT IN USE. 3. Attach an unused nozzle and disengage the safety on the foam applicator. 4. To meter the foam applicator, engage the trigger one-third to one-half. 5. After spraying, engage the safety on the foam applicator. Never spray foam more than one inch thick in a single application. Allow foam to cool between applications to avoid spontaneous combustion and to obtain maximum expansion. SYSTEM SHUTDOWN PROCEDURE (For end of day, replacing nitrogen tank or returning to Convenience Products) 1. Engage the safety on the foam applicator. 2. Clean any chemical from the front of the foam applicator barrel by wiping with a clean rag (Photo I). 3. Reattach the used nozzle. This provides an airtight seal during storage. 4. Turn off all valves. 2 on/off valves hose-to-applicator 2 on/off valves tank-to-hose 2 nitrogen intake valves 2 chemical tank valves Touch n Seal 1.75 pcf Slow Rise 175 psi 1.08 1.16 5. Turn off the nitrogen cylinder by turning the valve in a clockwise direction. 6. Rewind foam applicator and chemical hose assembly without draining. Store off ground.

D G J A B E F F E L REFILL SYSTEM CONFIGURATION *DIAGRAM NOT TO SCALE ALPHA ID ITEM NUMBER ITEM DESCRIPTION A 4505100003 A 17 Gallon 1.75 PCF STD Refill B 4505100004 B 17 Gallon 1.75 PCF STD Refill D 4505100012 Foam Applicator w/ 12 Hose E 4505100025 Filter Assembly, Refillable F 4505100040 On/Off Valve, Tank-to-Hose G 4505100050 On/Off Valve, Hose-to-Applicator H 4505100045 Hose Set, 30, Refillable J 4505100055 Hose Set, Nitrogen, Refillable L 4505100065 Regulator, Nitrogen M 4505100080 Nozzle Kit, Calibration, 25 Pack N 4004529930 Nozzle Kit, Clear, Conical, 25 pack O 4004529940 Nozzle Kit, Yellow, Fan, 25 Pack P 4004529968 Nozzle Kit, Black, Injection, 25 Pack Q 4505100048 Nitrogen Pressure Control Gauge Refill M H N O P Q

STORAGE Store in a dry area between 60 90 F (16 32 C). DO NOT store at temperatures above 120 F (49 C), near steam, open flames, sparks, hot water pipes, chimneys or heat vents. If a partially used system remains inactive for a period of time, the system should be pressurized and purged every two weeks by dispensing product until chemicals flow forcefully. This will prevent crystallization of the chemical and clear old product from the hoses. Follow instructions in SYSTEM SHUT-DOWN PROCEDURES and STORAGE. Unopened chemical tanks have a shelf life of approximately one year. CAUTION Building Codes In many areas, building codes may restrict the use of cellular plastics or polyurethane foam as exposed, finished material applications. Under certain application codes, the use of these materials may be prohibited. The foam produced by this product is organic and may constitute a fire hazard if improperly applied. Consult local building codes. Surface Temperatures Polyurethane foam should not be used in direct contact with chimneys, heat vents, steam pipes, or other surface areas that exceed 240 F (116 C). The cured foam should not be left exposed or inadequately protected when used as an interior and exterior finishing material. In all applications, it is strongly recommended that the foam be protected by approved facings and coatings. Open Flame Do not operate the system while smoking or in close proximity to an open flame. Welding on or near cured polyurethane foam requires special precautions. Excessive Foam Do not apply in layers exceeding one inch at a time, as this may result in spontaneous combustion. For a cured foam thickness greater than one inch, dispense foam in multiple layers allowing each foam layer to dissipate the heat between sprayings. RETURN PROCEDURE 1. Follow shutdown procedures. 2. Wear personal protection equipment. 3. Remove nitrogen hose set from cylinders. 4. Disconnect chemical hoses from filter assembly on chemical tanks. Note: A small amount of chemical may drain from the ball valve and/or filter. 5. Unscrew the filter assembly from the ball valve and discard the filter assembly. Coat the plug threads stored in the canvas bags on top of the chemical tanks, with the lubricant provided in the bag. Reinsert the plugs into their original chemical pipe location. Reinstall the nitrogen intake caps. 6. Place empty chemical tanks onto a sturdy pallet and secure for return. See photo J for proper securing method. 7. Call (800) 357-9199 for return. SAFETY PRECAUTIONS WARNING: These instructions are designed to protect users who follow the safety precautions and wear recommended protective equipment. However, accidents may result from misuse, carelessness, or disregard of cautions and warnings contained within this manual. Use only in a well ventilated area or with proper respiratory protection. Refer to Safe Use, Storage and Handling document for additional safety precautions. Always engage FOAM APPLICATOR safety when not in use. For more specific information about the chemical components A and B, refer to the appropriate Material Safety Data Sheet (MSDS). KEEP OUT OF REACH OF CHILDREN. Photo J CORRECT First, secure canisters together with banding or stretch wrap. Then, use banding to secure the canisters to the skid. ROUTE BANDING THRU TOP OF CANISTERS AND AROUND SKID STRINGERS. Photo K INCORRECT Canisters not properly secured and top skid boards pulled loose. DO NOT ROUTE BANDING THRU OR UNDER TOP SKID BOARDS. Limited Warranty Please carefully read and strictly adhere to the directions, warnings and cautions contained in or affixed to this product. The user assumes all risk as to the use of the product. Failure to follow all instructions, directions, warnings, and cautions shall release Convenience Products from any and all liability. Representatives, distributors and dealers of this product may make no claims or warranties not herein expressed. Emergency Telephone Number Chem Tel, Inc., 1305 North Florida Avenue, Tampa, FL USA 33602-2902 Toll-Free: 888-255-3924. International: 813-248-0573 Website: www.chemtelinc.com Caution The contents of tanks A and B are under pressure. The A tank contains polymeric isocyanates, the B tank contains polyols with amines and both tanks contain hydrofluorocarbons (HFC). Convenience Products 866 Horan Drive, Fenton, MO 63026-2416 USA 1-800-325-6180 www.touch-n-seal.com 4505100023 52117-062116-TNS