RELIEF VALVES. General Description

Similar documents
A soft sealed atmospheric safety valve with large flow capacity and soft seat tightness for steam condenser and turbine applications

Atmospheric relief valve type 1100 Installation and maintenance instructions

ROTATING DISK VALVES INSTALLATION AND MAINTENANCE 1. SCOPE 3 2. INFORMATION ON USAGE 3 3. VALVE TYPES 3 4. OPERATORS 5 5. VALVE CONSTRUCTION 6

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

776 Cryogenic Safety Valve

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

Installation, Operation and Maintenance Manual for Back Pressure Regulator

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

756 Safety Relief Valves

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

DUPLEX TECHNICAL INFORMATION FABRICATED DUPLEX STRAINERS

SAN ANTONIO WATER SYSTEM I.H. 10 Ground Storage Tank Rehabilitation and Painting Project SAWS Job No Solicitation No.

TECHNICAL DATA OBSOLETE

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Eaton Filtration, LLC

MSC Guidelines for Pressure Vessels

SCA Series Inverted Bucket Steam Traps

INSTRUCTION MANUAL. Anchor Darling 800 Globe Valves. Installation Operation Maintenance. Sizes 1/2 through 2 FCD ADENIM

Eaton Filtration, LLC

Pressure reducing valves Index

Speed control assembly model A-1

Blowdown vessels Meeting the requirements of HSE PM60

What is pressure relief valve? Pressure relief valve

Model PRS-07i. Stainless Steel Low Pressure, In-Line Pressure Regulator (Reducing Valve)

Model MTB-ASME Horizontal Bladder Tanks

Horizontal Bladder Tanks

Vertical Bladder Tanks

WHEATLEY Series 500 Swing Check Valve

FILTER BYPASS CONTROL

CAST IRON SAFETY VALVE TYPE 6301

v. Size shall be specified on drawings.

TECHNICAL DATA. Q = C v P S

Rules for the Installation, Inspection and Testing of Air Reservoirs (Other than on Locomotives)

GREIG FILTERS, INC. OPERATION MANUAL

Safety Valves. Expertise and solutions for steam, gas and liquid applications MECHANICAL SOLUTIONS

Welcome to the LESER Seminar, Taipei 28. June Design_of_safety_relief_valves_250804_Cal

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

for Stainless Steel Lines of Pressure Vessels, Hot Water Boilers, Heat Exchangers, Secondary Side of Pressure Reducing Valves etc.

6301 TYPE CAST IRON SAFETY VALVES

INSTRUCTION MANUAL Pressure Relief Device LPT

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE

Model MTB-ASME Vertical Bladder Tanks

MUD 1. Vent check valves. Instruction and maintenance manual.

4.0 DOT CYLINDERS 17

High Pressure Equipment Taper Seal Valves, Fittings and Tubing

Model MTB-ASME Vertical Bladder Tanks

Types 95L and 95H Pressure Regulators

ISO INTERNATIONAL STANDARD. Cryogenic vessels Pressure-relief accessories for cryogenic service Part 1: Reclosable pressure-relief valves

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified

Pressure Regulator B-95

Pressure Reducing Valves Pressure Reducing with. Broady Flow Control. D Series Range. Pressure Reducing Valves. Broady Flow Control

ASME SECTION I & VIII STEAM, AIR AND GAS SERVICE. 119 series cast iron flanged safety valves

Petro-Chemical & Analyzer Sampling Systems

Petro-Chemical & Analyzer Sampling Systems

PROCEDURES FOR REPAIRS TO ASME NV STAMPED PRESSURE RELIEF DEVICES OF NUCLEAR SAFETY RELATED PRESSURE RELIEF VALVES

29 SERIES - SAFETY VALVE

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

for Building facilities Industrial facilities etc.,multipurpose Pilot operated type(high capacity)

BACK PRESSURE / SUSTAINING

Installation, Operation and Maintenance Instructions for Direct Hot Water Storage Vessels

Vertical and Horizontal Bladder Tanks

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

Regulations Respecting Compressed Gas Pressure Vessels

BACK PRESSURE / SUSTAINING

SV60 Safety valves. for use with steam, gas and liquids

TECHNICAL DATA. Q= Cv S

Contents. LWN edition:

Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel

ASME and PED Requirements for Drum Level Instrumentation. Presented by: Amir Hedayatnia Clark-Reliance Corp.

L21S/SR/ST Glass Level Gauges

LARGE R/W GATE VALVES

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Rate of Flow Valve Series 120

FUNDAMENTALS OF PRESSURE RELIEF VALVES IN NATURAL GAS INSTALLATION - OPERATION - MAINTENANCE. Gary S. Beckett

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions

SV5 Safety Valve Installation and Maintenance Instructions

Installation, Operation, and Maintenance Manual

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

VAPOR CONTROL SYSTEMS QUALITY, DEPENDABILITY, SERVICE. REPUTATION BUILT ON. Valve Concepts, Inc. com. A Cashco, Inc.

End Connection. Thread x Thread N/A N/A N/A N/A Flange x Flange N/A

Technical data. Back pressure limit: 27.5% of set pressure. Capacity certification: ASME Boiler & Pressure Vessel Code Section I and VIII

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

SECTION I REGULATORS

Tank Blanketing Regulators

TECHNICAL DATA. Q = C v P S

M A B MAB INFLATABLE GASKET SLIDE VALVES SERIES TSV FOR POWDERED AND GRANULAR SOLID MATERIALS

TECHNICAL DATA. Q = C v P S

The flow direction must be observed during installation. It can be recognized by the following features: Flow direction. Gasket

excellence of Italian engineering Field adjustable PRESSURE RELIEF VALVES

Cash Valve. Type G-4. Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases. Flow Control

MONOPLACE HYPERBARIC CHAMBER FOR DIVERS TRANSPORT MODEL OXICAB MO-BZ-TR TECHNICAL OFFER

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

Manual Actuated Boiler Blowdown Valves

Installation, Operation and Maintenance Instructions Buffer Vessel OM006

Transcription:

RELIEF VALVES FOR CONDENSER SERVICE General Description Graham Viking Valves are produced in three basic designs: Horizontal, Vertical and Angle. The Horizontal and Angle valves are available with various angular relationships between the inlet and outlet flanges to facilitate piping. Fabrication is achieved by welding procedures and welders qualified to Section IX of the ASME Boiler and Pressure Vessel Code. All valves are tested to ASA standards and are vacuum tight; all valves also receive in-process inspection as well as inspection prior to shipment to assure proper operation at the site.

UNIVERSAL VALVE CLOSURE Specifically designed for condenser service, Graham Viking Valves feature a universal valve closure. This novel design permits us to offer high performance characteristics at lower costs and most important with less lead time from receipt of your order to delivery at your job site, ready for inspection. DESIGNED FOR LONG TROUBLE-FREE SERVICE Viking Valves are designed and built with uncompromising quality so that they can be installed with complete assurance that they are equal to any emergency. Seating surfaces are stainless steel with O ring seal or stainless metal-to-metal. Bronze, Monel or other special alloys may be specified, depending upon corrosion problems. In operation, the valve remains tight under full vacuum and opens automatically above atmospheric pressure. After releasing excess pressure, the valve will reseat itself and remain tight. To provide faultless operation, all moving parts are machined to close tolerances and are designed with adequate guidance. Graham valves are also designed to provide a water seal around the valve disc if desired. Horizontal unit with top removed exposes valve seal and seat facing. Handwheel, integral with top section, activates lift mechanism. HOW TO SELECT PROPER SIZE The table below indicates the correct valve size based on the throughput of steam. These recommendations are based on the Standards for the Heat Exchanger Institute. SIZE SELECTION GUIDE OFF-THE-SHELF AVAILABILITY Graham Viking Valves are available in standard sizes from 4 to 36, with larger sizes available on request. Standard construction features ASA standard flanges and drilling, steel construction, and stainless steel trim. Special materials of construction are available for unusual services. The 6,8,10, and 12 valves are available off the shelf. Larger sizes 14,16,18, and 20 valves are available for delivery on short notice. The 4 valve, and the larger sizes up to 36 or more are available for delivery within six weeks. The above ratings are applicable to surface condenser service. For ratings of the 4 and 5 size valves, and for applying the above valves to other relief applications, consult your Graham Sales Representative.

HOW TO ORDER When ordering or requesting specific information, please include the following particulars for either a replacement valve or spare parts: A. A complete description of whether horizontal, vertical or angle is required. B. Specify size. C. Specify special materials of construction, if any. D. Advise if water seal is wanted and gauge glass required. E. State number of valves required and delivery schedule. Spare parts are available for immediate delivery on any size valve. Please state serial number of valve and parts required, indicating item numbers from drawing. FINISHED WEIGHTS BY TYPES AND SIZES Condenser Service Relief Valves Size Vertical Angle Horizontal 4 106 122 139 5 117 134 152 6 154 178 202 8 234 276 318 10 312 372 431 12 449 537 625 14 580 683 787 16 515 631 748 18 732 893 1055 20 791 980 1169 24 1074 1352 1630 30 1517 1915 2313 36 2509 3054 3598 gauge glass for above valves if required Graham Corporation 20 Florence Ave., Batavia, NY 14020 USA Phone: 585-343-2216 FAX: 585-343-1097 Email: equipment@graham-mfg.com Web site: www.graham-mfg.com Graham Corporation. All rights reserved, worldwide.