COMBIMASS. Thermal gas flow measurement system. For measuring and balancing of normal volumetric or gas mass flows

Similar documents
CAMASS. Calibration Centre. Gas flow technology and services

CAMASS. Calibration Centre. Gas flow technology and services

Flow metering in gases Introduction to COMBIMASS family

INSTRUM. Pressure regulators Flow restrictors Safety elements. For protecting explosive, corrosive and sterile processes with inert gases

VACOMASS. The modular air supply system in wastewater treatment plants

analytical bulk flow distance FLOW level pressure temperature industrial communication

deltaflowc deltaflowc Venturi or Probe

Liquid Ring Compressors Engineered-to-Order Compressor Systems

Liquid Ring Compressors Engineered-to-Order Compressor Systems

Liquid Ring Compressors Engineered-to-Order Compressor Systems

Over 20,000 Strain Gage Target flowmeters installed since 1952.

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N

deltaflowc deltaflowc Gas Massflowmeter Venturi- and Probe Type

Unique mounting features for Thermal Mass Flow Meters. By Martin Raab in cooperation with CaTeC b.v.

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

Vortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features

Features. Description

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Design. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Vortex Meters for Liquids, Gas, and Steam

Products Solutions Services. Gas Flow Measurement

LFE OEM TCD - Thermal Conductivity Detector

Gas Analysis Isn t Exactly Your Only Priority? Luckily For You, It s Ours. SIPROCESS GA700 effortless gas analytics from Siemens. siemens.

Premium Solutions for Gas and Biogas Handling

better measurement Simply a question of

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

deltaflowc deltaflowc Venturi or Probe

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

780S Ultra High Purity Series

Product Information. Three in One: Gas Meter Tariff Device Volume Corrector. Ultrasonic Gas Meter ECOSONIC X12

FLOWSIC100 Flare Challenges in Ultrasonic Flare meter field installations. History of Evolution

Digital Mass Flow Meters and Controllers for Gases

SITRANS P measuring instruments for pressure

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

Online data sheet FLOWSIC30 GAS FLOW METERS

IBEDA GAS MIXERS HIGHEST PRECISION FOR YOUR WELDING AND CUTTING PROCESSES

EasyLine Continuous Gas Analyzers. So smart, they re simple

Oxygen & Binary Gas Measurement and Analysis

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

Micro Motion 3098 Gas Specific Gravity Meter

h2000 plus HyDROGEN LEAk DETECTOR

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

Technical Datasheet ZHA Series Gear Flow Meters Aluminum Version with ball bearing for lubricating media

Pressure measurement is a family affair

NGN Series nitrogen generator

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.

Thermal flow sensor TA Di for separate evaluation units for measuring mass flow, standard flow rate and air or gas consumption.

Pressure & Temperature Switches

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

AUTOMATIC HOSE TEST UNIT, TYPE SPU

THERMAL MASS FLOW MEASUREMENT FOR GASES

ZHM ST Series. Technical Datasheet. Gear Flow Meters for lubricating, non lubricating, abrasive and corrosive fluids

Mass Flow Controller (MFC) for Gases

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

Non-intrusive Natural Gas Flow Measurement

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

ABB MEASUREMENT & ANALYTICS. Continuous gas analyzers EL3060 The specialists for hazardous areas

LUGB Vortex Flowmeter

USE A RELIABLE A INNOVATIVE A COST EFFICIENT GAS EQUIPMENTS AND GAS SYSTEMS

Pressure measurement is a family affair

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

800 Series Mass Flow Meters and Controllers. High Performance Mass Flow Meters and Controllers

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use

Columbus Instruments

Porter Analytical & Industrial Products

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

For the highest operational safety around the clock

Variable Area Flow Meters

Selecting the right pressure sensor for your application

Expert Hydrostatic Level Transmitters

7Flat-Trak Model 780S. Smart In-Line Thermal Gas Mass Flow Meter with Flow Conditioner. For information online...

TF- & DM-Series. Turbineflowmeter

Flexible Engineered Solutions International CALM Buoy Swivels

Valvex Valves for Mining Applications

Ultrasonic Flowmeter USZ 08

NEW VERSAFLOW CORIOLIS

Flow Measurement SITRANS F C

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

USER'S MANUAL HOT-WIRE TYPE GAS SENSOR NAP-100A SERIES ( NET10A(R) ) (For All Combustible Gases)

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

KMT. Thermal Mass Flowmeter. for compressed air and gases. Measuring range: Nm³/h Nm³/h

Shanghai AEAD Technology Co., Ltd Professional Manufacturer of Flow, Level, Pressure, Temperature

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

New! ProFlow. Sliding Vane Meters DN (½ - 2 ) _ 142. Product Bulletin

System REITHER A Patented Venturi Scrubber

Ultra High Purity Model 780S

COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS

SRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic

Integral type Differential pressure flowmeter VNT Series

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

A new concept in the storage of liquefied chemical and petrochemical gases Zero leakage Zero fugitive emissions

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

Transcription:

Thermal gas flow measurement system For measuring and balancing of normal volumetric or gas mass flows

The COMBIMASS series enables direct measurement of the normal volumetric flow or gas mass flow, unaffected by pressure and temperature fluctuations. Various basic modules can be combined with different sensors in any manner. The modular concept is characterized by its advanced electronics multiple combinations as well as the expandability of the system. COMBIMASS sensors for thermal gas flow measurement are designed for minimal pressure loss are robust, corrosionresistant and require minimal maintenance have no mechanical moving parts and are available in various models and probe geometries. The use of state-of-the-art sensor technology ensures precise measuring results which are stable over time, even under extreme conditions and at high temperatures. With COMBIMASS you can assemble your gas flow meter individually according to your specific application.

The principle of thermal measurement Gas molecules flowing past a heated sensor element absorb heat energy causing it to cool down. This effect is used by COMBIMASS for thermal flow measurement of gases. The degree of cooling depends directly on the number of gas molecules passing the sensor and therefore is a direct measurement of the gas mass. With other techniques of gas flow measurement the operating volumetric flow is usually measured instead of the mass flow. In such case the reading of the flow meter varies greatly according to pressure and temperature fluctuations. The constant temperature principle is mainly used for special measuring tasks. It is well known for its quick response characteristics. With clean gases the constant temperature principle is ideal for measuring high flow rates or monitoring dynamic processes. COMBIMASS uses both techniques and allows to select the measuring mode depending on the specific requirements of the application or measuring task. The COMBIMASS sensors are unmatched in precision and stability Flow Heated sensor Reference element No flow COMBIMASS measures in dry gases directly the standard volumetric flow or the mass flow of the gas respectively according to DIN 1343. This key value for the flow rate is independent of the operating state of the gas and may be compared directly. A heated sensor element and a reference element are used to determine the quantity of heat absorbed by the flowing gas. This value is directly proportional to the gas mass flow. Signal processing occurs either at constant heating power by evaluating the temperature differences between both sensor elements or at a constant temperature differential by readjusting and evaluating the required heating current. Thus a basic distinction is made between the following two principles: The constant power principle has proven to be ideal for process applications and is characterized by an extremely stable flow signal. This measuring mode is the best choice for monitoring of low flow rates, for measuring dirty and moist gases and for regulating tasks. The choice of an appropriate sensor is crucial for precise gas flow measurement in various applications and process conditions. Therefore COMBIMASS sensors differ in design and probe geometry. Various sensor models Best choice for each application Heavy-duty, fully welded sensors made of stainless steel or other special materials are available for a variety of applications. Depending on the nominal pipe size and the type of application, these probes are available in different diameters and lengths as well as with various process connections. All sensor heads are made from one-piece solid bar-stock construction. The sensor elements High-tech in detail All probes of the COMBIMASS series use technologically advanced sensor elements of the latest generation. The platinum thin-layer resistors are randomly distributed on a ceramic board. The structures of the sensor elements are created using modern manufacturing laser technology. COMBIMASS sensors are characterized by high-precision resistors minimal drift of the raw signal excellent long-term stability all this even under harsh operating conditions and at high temperatures.

The modular concept The COMBIMASS series of gas flow meters is unique due to its advanced modular design. Various basic modules are available which may be combined as desired with different sensors. In this way the modular concept of the COMBIMASS series enables ideal configuration for any possible measuring task. Each flow meter can be customised to fit the application and your specific requirements. Once installed, a COMBIMASS system can also be further expanded. Thus changes in requirements do not require expensive replacement by a new, higher performance device. Besides various basic modules you have the choice between COMBIMASS sensors available in different materials, dimensions and with various process connections. In addition these sensors are distinguished by their probe geometries. During installation of the 2-pin sensor type, the flow direction of the gas has always to be considered in order to guarantee precise flow rate measurement. This is balanced by some operational advantages in case of fast changing temperature of the medium to be measured. The 2-pin geometry also has proven to be reliable since many years. The 1-pin sensor type uses a unique sensor element developed especially for such probe geometries. The heated measuring resistor and the reference resistor are mounted on a single ceramic board. Due to the rotationally symmetrical design this thermal probe will always have identical flow to both thin layer resistors, thus avoiding erroneous measurements by turning the flow sensor during installation or maintenance work. This contributes to higher reliability in measuring gas flows.

The basic modules COMBIMASS enables the combination with various basic modules and for this reason an ideal configuration for any possible measuring task. Each flow meter can be customised according to the application and the requirements. The basic modules Field transmitter: COMBIMASS basic Basic flow meter for flow rate measurement of compressed air and technical gases at process temperatures up to 130 C COMBIMASS eco Flow meter for various standard applications even in potentially explosive areas and at process temperatures up to 220 C COMBIMASS compact High performance flow meter for extreme applications even in hazardous areas and at process temperatures up to 580 C COMBIMASS eco-bio+ SS/AL respectively COMBIMASS oem-bio L Customised system for original equipment manufacturers such as manufacturers of biogas plants or gas compressors as well as operators COMBIMASS monitor Flow switch for gases and liquids, a switch for level, foam and separation layer detection as well as for monitoring and run-dry protection of pumps. DIN rail module: COMBIMASS master Microprocessor based electronic module with additional signal inputs and outputs as well as extended monitoring, correction and evaluation capabilities for highly demanding application, also with data-logger COMBIMASS multi Electronic module for multipoint measurement or redundant monitoring of gas flows with plausibility checking and various evaluation options (single point analysis, averaging, etc.) COMBIMASS I.S. interface I/O module specially developed by BINDER for COMBIMASS in EEx[ia] Zone 0-applications Customised COMBIMASS products built out of the modular components complete the program.

The electronics Due to the visionary sensor query and digital signal processing the COMBIMASS electronics are distinguished by their superior stability and reliability. The use of state-of-the-art components allows the electronics to be miniaturised in size, such that the data storage for calibration and sensor data as well as the entire signal analysis functionality can be incorporated into the sensor head. Thus it is possible to read out and check the sensor data. If the sensor is connected to the electronic interface the sensor electronics transfers the application data to the external module. COMBIMASS in action Modern technology and the consideration of high safety standards allow these thermal gas flow meters to be deployed not only for simple applications but also in areas with explosion hazards, at high pressures and for process temperatures up to 580 C. Manual or hydraulically operated hot tapping units for operating pressures up to 100 bar and process temperatures up to 450 C are used to insert or retract the sensors during operation. This enables the sensors to be checked, cleaned and maintained at any time without difficulty. The COMBIMASS electronics allows to select different measuring modes. Operation of the flow meters can be according to the constant power principle or the constant temperature principle, thus offering the greatest flexibility for every application and measuring task. The measuring mode will be selected before system calibration but can be changed at any time as needed. Explosion protection without compromises COMBIMASS flow meters are available in explosion proof version according to ATEX regulations. The instruments can be configured as intrinsically safe versions EEx [ia] or shipped with a pressure-proof dual compartment enclosure rated EEx [ed] for hazardous location use. The EEx [ia] configuration meets the requirements of category 1 as well as temperature class T4. COMBIMASS flow meters therefore meet the highest safety standards and can also be used for applications in explosive areas classified up to zone 0. Versions for zone 1 and 2 are also available. Thus these devices cover a broad spectrum of process applications in the chemical and petrochemical industries up to biogas plants. COMBIMASS handles the pressure The solid machined sensor points of the COMBIMASS series are welded to the sensor rod with a single weld only. This allows all sensors to be manufactured with tested welds. COMBIMASS flow meters therefore meet the requirements of the PED and the AD 2000 for pressurized components and can be used without observing any particular safety guidelines even at high operating pressures. Subsequent inspection of the plant after installation of the flow meter by a qualified technician is not necessary.

flow meters are versatile and can be used anywheree The devices measure the flow rate of compressed air, supply and process gases of pure gases and gas mixtures of clean and sterile gases of dirty, moist or corrosive gases of flammable and toxic gases in all kind of industries for the most diverse applications. The high-performance gas flow meters measure directly the normal volumetric or the gas mass flow in dry gases unaffected by pressure and temperature fluctuations with a turndown ratio up to 1000 : 1 an accuracy up to 1% at process temperatures up to 580 C operating pressures over 100 bar and guarantee always precise and reliable results even for difficult measuring tasks. COMBIMASS flow conditioner COMBIMASS flow conditioners are used in the case of a complex pipe geometry with bends, reducers, fittings or pulsation of the gas flow. They balance out almost without any pressure loss the flow profile and ensure that there are reproducible conditions at the measuring point. With COMBIMASS flow conditioners the measuring section is only up to 3-7 fold of the pipe diameter. They are robust, insensitive to dirt and guarantee the highest measurement accuracy. The principle: At the inlet, swirl-reducing guide plates cause countervortices which neutralize the swirl flow. Profile guide plates create cross flows, which are mixed with the fast and slow speed regions. Finally, a homogeneous outlet flow is generated. COMBIMASS always the best choice for your specific application The COMBIMASS series of flow meters was developed for a great variety of different applications in all kind of industries. For sterile applications, such as in pharmaceutical or food industry, COMBIMASS sensors are available with highly-polished surface, approved materials and special process connections. Models made of Titanium, Tantalum, Inconel, Hastelloy, Ceramic or Carbide are used to measure corrosive, osive, aggressive or abrasive gases or gas mixtures. As you can see, COMBIMASS covers a broad range of diverse applications and can be configured for any possible measuring task.

Applications biogas flowmeter and biogas analyser Variable methane concentrations in wet and corrosive gases combined with dirty particles are a challenge for each gas mass flow measurement system. A gas mass flow meter with integrated humidity correction allows to measure the biogas flow at standard conditions according DIN 1343. Using a further combination with a gas analyser, the gas mass flow can be corrected by the measured methane concentration in the gas. The biogas analyser COMBIMASS GA-m is a very compact and rigid hand held instrument which can also be used in a stationary version COMBIMASS GA-s. The biogas analyser has an outstanding performance and is very flexible and easy to handle. The improvement of measurement accuracy and reliability causes a significant increase to the efficiency in the energy generation out of biomass. Flaremass Variable operating conditions and mixed gases are a challenge for the COMBIMASS flare gas measurement system H 2 -inline-compensation, mixed gas lab calibration possible at CAMASS Calibration Center and on site inline validation system, flow conditioning, multi-point measuring systems hot tapping unit, direct mass measurement, irrespective of pressure and temperature easy installation, measuring range 1000 : 1 at minimal pressure loss corrosion-resistant sensors, insensitive to dirt. Multipoint measurement Flow profile distortions, such as those which occur with large nominal diameters, rectangular ducts and short inlet and outlet pipe sections, lead to errors in the flow rate measurement of gases. COMBIMASS multipoint systems measure the flow velocity of gases at various points of the cross-section and averages the individual readings. Thus errors caused by flow profile distortions are suppressed and the measurement system provides correct values of the flow rate even at unfavourable installation position of the thermal flow sensors. Additional applications COMBIMASS measuring systems can also be used as monitor and flow switch for gases and liquids, as switch for level, foam and separation layer detection, for run-dry protection of pumps as well as for monitoring of lubricating circuit. CAMASS calibration technology With such high-precision measuring technology, correct calibration of the gas flow meters is the key to precise flow rate measurement. In our CAMASS Calibration Center, exactly the same process conditions that will be encountered later in your plant will be simulated for gas flow calibration. Each flow meter is calibrated individually in our flow stands. The modern CAMASS Calibration Center offers technology and service for gas flow applications even for corrosive and explosive gases and this with nominal diameters up to DN 500 as standard operating pressures from 0.1 to 100 bar (abs) operating temperatures up to 500 C standard flow velocities from 0.01 to 600 m/sec volume flows up to 90 000 m³/h at standard conditions. Besides various international standards for flow rate measurement, the laser doppler anemometry is used as a reference as well. This optical measuring technology requires no calibration and determines gas flow rates unaffected by pressure and temperature fluctuations with an overall accuracy of +/- 0.2%.

Applications General industrial use: Flow rate measurement, recording and balancing of compressed air, technical and combustion gases such as nitrogen, argon, oxygen, superheated steam or propane, butane, etc. Sewage treatment and environmental technology: Measurement, balancing, control and distribution of aeration air, digester gas, landfill gas, biogas, natural gas, ozone and oxygen. Flow measurement and monitoring of exhaust air, waste gases, low temperature carbonization gas, flue gas, etc. Power plants, garbage incineration plants: Flow rate measurement of combustion air, residual gases, flue gas and ammonia. Refining, petroleum processing: Hydrocarbons, hydrogen sulphide, flare gases, hydrogen/ hydrocarbon gas mixtures even with a high quantity of particles and variable composition. Pharmaceutical, biotech, food and beverage industries: Nitrogen and supply gases, sterile gases, hot air for sterilization chambers, solvent vapors, waste gas and air exhaust. Chemical industry: Monitoring and control of synthetic processes. Flow rate measurement and balancing of supply and process gases such as air, nitrogen, hydrogen, chlorine, ammonia, hydrogen sulphide, amines, phosgene, acetylene, hydrocarbons, gas mixtures, exhaust air and waste gases, combustion and flue gases. LOCAL DISTRIBUTOR PRODUCTION BINDER GmbH Buchbrunnenweg 18 89081 Ulm, Germany Tel +49 731 18998-0 Fax +49 731 18998-88 info@bindergroup.info INSTRUM AG Waldeckstrasse 100 4127 Birsfelden, Switzerland Tel +41 61 3121136 Fax +41 61 3121126 info@instrum.ch www.instrum.ch BETA BV Verrijn Stuartlaan 22 2288 EL Rijswijk, The Netherlands Tel +31 70 3199700 Fax +31 70 3199790 info@beta-b.nl www.beta-b.nl DISTRIBUTION Binder Engineering GmbH Buchbrunnenweg 18 89081 Ulm, Germany Tel +49 731 96826-0 Fax +49 731 96826-99 info@bindergroup.info Binder Engineering AG Waldeckstrasse 100 4127 Birsfelden, Switzerland Tel +41 61 3199130 Fax +41 61 3199134 info@bindergroup.info Binder Engineering BV Cort van der Lindenstraat 25 2288 EV Rijswijk, The Netherlands Tel +31 70 3074300 Fax +31 70 3074399 sales@binder-engineering.nl Binder Engineering NV Bergensesteenweg 709 A 1600 Sint-Pieters-Leeuw, Belgium Tel +32 2 3000795 Fax +32 2 3000797 info@binder-engineering.be Binder Engineering SAS 41, Place Jules Ferry 92120 Montrouge, France Tel +33 1 46120445 Fax +33 1 46120442 binder@mesa.fr Binder Instrumentation Pte Ltd 25 International Business Park #04-103K German Centre Singapore 609916 Tel +65 6 5627631 Tel +65 6 5627637 Fax +65 6 5627638 eddy.eng@bindergroup.info Binder Instrumentation Trading (Shanghai) Co., Ltd Room 106A Xingyuan Tech Building Guiping Road 418 Shanghai, P.R. China, 200233 Tel +86 21 64959889 Fax +86 21 64959887 info@binder-instrumentation.cn Please visit our website for more information and distribution in other countries: Please contact the company with the address shown in red or the local distributor. All rights reserved. Subject to change without notice.. BIDE-M-PROS-COMBIMASS002-EN-R02 Fotodesign Horst Haas