Manifolds & pressure reducing sets

Similar documents
AUTOMATIC GAS MANIFOLDS

MANUAL GAS MANIFOLDS

CPX EMERGENCY STANDBY MANIFOLD INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

PureGAS Manifold Control Panel - HTM02-01

PRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

MEDICAL EQUIPMENT CATALOG

Technical Datasheet. Rigid & Retractable Pendants. Rigid Pendant

CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES

DUPLEX PRESSURE REDUCING SET

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor)

AREA VALVE SERVICE UNITS

Installation & Maintenance Manual. Economy Manifold

Pressure Differential Automatic Manifold For LPG. PDH1000 Series. LPG Installation & Operations Instructions

Specialists in HTM Medical Gas Pipeline Equipment AVSU/Module Operating and Maintenance Instructions

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

Technical Specification

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

HYPOXIC AIR FIRE PREVENTION SYSTEM TECHNICAL SPECIFICATION

571 Series Medical TM. IntelliSwitch Electronic Switchover

Central System of Medical Gases

Installation Operating Instructions for Duplex Manual Manifolds PX-TMD Series

Installation & Maintenance Manual. C2 & C3 Manifolds

Products for Cryogenic Applications

Installation & Operating Instructions for Genesys Analog Series Manifolds

Installation & Operating Instructions for Genesys Analog Series Manifolds

Installation & Operating Instructions for Genesys Series Manifolds

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:

Installation and maintenance of twin 45kg LPG cylinder systems

Tri-Tech Medical Inc.

CAPITAL CONTROLS SERIES NXT3000

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

GUIDELINES FOR CONDUCTING HYDROGENATION REACTIONS

Inert Air (N2) Systems Manual

NGN Series nitrogen generator

Micro Dial-Flowmeter. Instructions for Use

BOC Healthcare Training

Zeus Area Valve Service Unit (AVSU) and AVSU Module. Installation, Operation and Maintenance Manual

Valve Proving System VDK 200 A S06*

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Valve Proving System VDK 200 A S02

SINGLE VALVE WITH LOW-FLOW BYPASS

Economy Manifold Alert -2. Installation and Maintenance Manual V1.6

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products


Flow meter. bellow vaporizer. APL valve. Scavenging system

Dialflow Regulator. Instructions for Use

Fully Automatic Gas Manifold. Patent US 7,013,906. Installation & Operation Manual

Zeus Vertical Headwall

AUTOMATIC GAS MANIFOLD

Central Gas System Inquiry. Check List - Detailed Form

Locator Locator-D-Lux Air-Saver G1 Air-Saver G2

TECHNICAL DATA. Trimpac 257a. September 16, 2013

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

BOC Healthcare training

Installation Instructions for NP100 Series Nitrogen Control Panels

Oxygen Dialflow Meter. Instructions for Use

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

GCE CENTRAL GAS SYSTEMS THE DRINKS DISPENSE INDUSTRY EQUIPMENT FOR GAS SUPPLIER SYSTEMS

ECS Protector Nitrogen Generator PGEN-30 (PGEN-30E)

Pressure Regulators. Instructions for Use

System Pressure Manager Standard & System Pressure Manager Plus

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

IntelliSwitch II Electronic Switchover

MEDAP-MOBILE GAS SUPPLY

Narkomed MRI-2. A perfect fit for the MRI environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Oxygen Dialflow Meter. Instructions for Use

[Instruments for vacuum measurement, checking and adjustment] 3

Specification for Medical Gas Pipeline s

GM2 SERIES DOME BIAS AUTOMATIC MANIFOLD

Gas Cabinets and Valve Manifold Boxes: Applying CGA G13- Rev 2015 to Gas Delivery Equipment

Nitrogen Generators. PMNG Commercial Series. Section 50 Bulletin A -20

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

TECHNICAL DATA. Trimpac 256a. October 31, 2013

NTF-515. Operation Manual

About. providing superior performance and reliability. Bromic regulators are AGA or UL144 approved.

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

Pressure Regulator. Instructions for Use

SERIES-O REGULATOR. Instructions for use

G SPECIFICATION: TITLE: VOLUME: 4 REVISIONS:

AutoChanger Installation & User Guide Issue 2

Flexible Pendant. Installation, Operation and Maintenance Manual

SCIENCE LAB UTILITY CONTROLS

New AQF Filter Polymer Filtration System

Protocol Switchover Station

SABRE AIRLINE BREATHING APPARATUS

OPERATION MANUAL NTF-15

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Installation and Maintenance Manual. Microprocessor Based Digital Manifold NFPA

Section 1.3: PRESSURE VESSEL COMPONENTS AND SYSTEMS AND COMPRESSED GAS CYLINDERS

Vaporizer Piping Liquid Chlorine Manifolds

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

Medical Gas Control Panel

TECHNICAL DATA. Q= Cv S

I. Subject: Medical Gas Systems Utility Failure Interim Procedure III. Purpose:

INSTRUCTIONS FOR HIGH PURITY, CHANGEOVER REGULATOR SYSTEMS (PCS, CRS SERIES)

Highest Quality. Gas Chlorination Systems

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

SPIROVENT VACUUM DEGASSERS

Transcription:

Manifolds & pressure reducing sets

Automatic Changeover Manifold (Electronic) Providing continuous supply of medical gases Pneumatech Medical Gas Solutions (PMGS) PureGAS Manifolds provide a duty or standby gas supply from two cylinder banks with automatic changeover, local status and remote indicator facility. These manifolds are suitable to supply medical gases for respiratory, clinical and surgical use in healthcare facilities. The PMGS PureGAS Automatic Manifolds are designed to supply the medical gas pipeline systems with a constant pressure supply via a control panel from two equal cylinder banks. The changeover from the DUTY to the STANDBY bank of cylinders take place automatically. Automatic changeover from the DUTY to the STANDBY bank occurs at a cylinder pressure that ensures the maximum usage of the contents of the DUTY bank. The normal operation of the changeover control depends on an electrical supply, the design of the unit ensures that in the event of an electrical supply failure, there is no disruption to the flow of gas into the medical gas pipeline system. Once the supply is restored the original running bank returns on-line. Systems are tested and verified within our factory and come fully certified for complete peace of mind. Cylinder Manifold Unit The cylinder manifold unit accommodates two or more cylinders in each bank. The supplied cylinder racks are powder coated steel and securely support cylinders of varying diameters. The cylinder tailpipes have gas specific connections to the manifold header, and cylinder connections have either Bullnose (BS 341) or Pin-indexed connectors (ISO 407).

Automatic Changeover Unit The changeover unit supplies medical gas at a constant pressure from either bank of cylinders into the medical gas pipeline system. Each unit has separate pressure regulating valves for each bank of cylinders and the control system is designed for ease of maintenance. Cylinders can be changed, or the pressure regulating valves removed for overhaul without loss of continuity of the gas supply. The PureGAS manifold is protected by glass-reinforced polymer moulding. System flow up to 1,750 l/min at 4 bar. Full colour, graphical display as standard. Digital pressure sensors for accurate reading and entire gas usage in cylinders. Average gas consumption calculation for non-liquefied gases. Control Panel kit comprises: changeover panel, isolation and relief valve assembly, and manifold connections. Manifold kit comprises: soldered manifold assemblies, cylinder racks, gas specific tailpipes to most international standards, cylinder restraining chains and cylinder toolkit (where appropriate). Manifolds extensions available for system expansion. CGA cylinder connections available on request. Note: Cylinders are NOT included with PMGS manifolds Gases and Services Oxygen Nitrous Oxide 50% Oxygen / 50% Nitrous Oxide Medical Air (400 kpa) Surgical Air (1,100 kpa) Laboratory Carbon Dioxide Nitrogen Easy Installation Preinstalled test point protected by fascia panel reduces installation time. Lightweight mounting bracket simplifies installation.

Control System The Control System located in dedicated enclosure, providing additional protection for electronic components. Manifold status indicators, including gauges, are visible without opening the enclosure. The manifold unit is provided with a full colour graphical display and membrane keyboard display and operates: 1. Cylinders pressure and remain volume (for non-liquefied gases); 2. Line pressure and average gas consumption; 3. Duty bank operating; 4. Duty bank empty (standby bank operating); 5. Standby bank below 10% (duty bank empty); 6. Reserve bank low; 7. Pipeline pressure fault; 8. General service warning (after 40,000 hours / 5 years). Dedicated enclosure increased protection. Dedicated alarm connection board for fast and safe connection. Power supply : 90-285 VAC 50/60Hz less stock, no errors. Supporting alarms with/without line monitoring - no additional termination boards. Dedicated service mode - no alarm transmitted. Conditions 2, 3, 4 and 5 can be transmitted into the main alarm system via volt-free contacts. Pressure gauges are also provided to indicate cylinder bank pressures and the distribution pressure. Digital pressure indication in both headers & line full control. Pressure in bar or psi no need for unit conversion. Due and reserve bank status no doubts about remaining gas volume. Average gas consumption costs under control. Embedded alarm no additional investments. Special service mode - no alarm transmitted. General service warning (every 40,000 / 5 years hours) - in-time reminder, reduces risks.

Emergency Reserve Manifold The PMGS Emergency Reserve Manifold (ERM) provides a continuous supply of medical gas from high pressure cylinders into the medical gas pipeline system at a constant pressure. The ERM is connected to the medical gas pipeline system via a non-return valve. One cylinder valve can be opened with the other closed as a spare. Changeover can be carried out manually when one bank of the cylinders is empty. The ERM is typically used as a reserve or backup gas supply, usually to a high demand system. Headers are complete with gas specific cylinder connections for flexible nickel tailpipes. Entire metal construction. Non-return valves fitted to each tailpipe connection East terminal unit test point fitted. Pre-wired terminal block for alarm output to the automatic changeover manifold. Complete manifold fitted to a wall mounting plate. Easy Installation Copper stub pipes for ease of connection to medical gas pipeline system using inert gas jointing procedures. Gases and Services Oxygen Nitrous Oxide 50% Oxygen / 50% Nitrous Oxide Medical Air & Surgical Air Carbon Dioxide Design The control assembly within the ERM regulates and controls the flow of gas from the cylinder header manifold. An integrated cylinder header manifold supports high pressure cylinders in racks and provides a gas specific connection, by means of manifold headers and tailpipes to either side of the control/regulator assembly. Nitrogen The PMGS emergency reserve manifold has two gauges, one to indicate the pressure in the cylinder and the other to show the regulated pressure being supplied into the medical gas pipeline system. Monitoring is provided to detect when the pressure in the cylinder has fallen to a predetermined level, with contacts for transmission to the main alarm.

Emergency Reserve Manifold Lite ERM Lite The new, simplified version of PMGS Emergency Reserve Manifold (ERM Lite) developed to be used in a small hospitals and clinics. The main difference between ERM Lite and a Standard version is its usage of a multistage regulator. Embedded test connection - savings on installation. Phthalate free multistage regulator. Pressure gauges to track pressure in each bank individually. Standard pressure switches included to connect to alarm system (automatic manifold). Prepiped vents - faster installation.

Pressure Reducing Sets The PMGS Pressure Reducing Set provides reliable pressure reduction of medical gases between the supply source and the distribution system. Pressure relief valves fitted as standard. Quarter turn ball valves fitted as standard. Duplex unit baseplate mounted as standard. Padlocks available to allow locking of the valves in both the open and closed positions. Easy to read pressure gauges. Easy installation Baseplate mounted duplex unit. Simplex unit mounted via munsen rings. Supplied with copper stub pipes for ease of installing using inert gas jointing procedures. Simplex Pressure Reducing Set comprises an in-line pressure regulator, with downstream pressure gauge. A pressure relief valve, capable of passing the full flow of the regulator is installed downstream of the regulator and isolation valves are fitted upstram of the regulator and downstream of the pressure relief valve. The PMGS Duplex Pressure Reducing Set has two branches as described, connected to the MGPS in parallel, in order to allow maintenance on the components of one branch while the gas flow is maintained in the other branch. Ball valves are full bore and operate from fully open to fully closed with a quarter turn of the handle.

Compliance HTM02-01, HTM2022, C11 and all related BS EN ISO standards. Service and maintenance Throughout the UK our network of service engineers provides full Service and Maintenance support of the highest quality. Outside the UK our fully trained distributors provide a similar local service. One year warranty from date of manufacture, excluding components designated as service items to be replaced by the customer as part of the published service schedule. 0088 www.p-mgs.com 8102341062 ed.3-2016, Pneumatech Medical Gas Solutions. All rights reserved. Designs and specifications are subject to change without notice or obligation. The colour of the actual products may vary from the colour shown in this brochure. Slight differences in detail might appear.