ATLAS RPC QA results at INFN Lecce

Similar documents
arxiv: v1 [physics.ins-det] 16 Aug 2014

Assembly and Testing of RPCs in Pakistan. Hafeez Hoorani National Centre for Physics

Preliminary results of Resistive Plate Chambers operated with eco-friendly gas mixtures for application in the CMS experiment

Analysis of RPC Performance with Different Gas Mixture

arxiv: v1 [physics.ins-det] 4 May 2016

arxiv: v1 [hep-ex] 18 Sep 2012

arxiv: v1 [physics.ins-det] 6 May 2016

The Resistive Plate Chamber detectors at the Large Hadron Collider experiments. Danube School, September 8-13, 2014 Novi Sad

Long term stability tests of INO RPC prototypes

Assembly and measurements of a mechanical prototype of the BIS MDT chamber

Monitored Drift Tubes in ATLAS. Michele LIVAN 1. Dipartimento di Fisica Nucleare e Teorica, Universita di Pavia

Status of MDT Production and Testing

Design and Construction of a GEM-TPC Prototype for R&D Purposes

RPC CHARACTERIZATION AND TESTING ( by S. Mathimalar, INO Student)

Performance of a triple-gem detector for high rate charged particle triggering

The Transition Radiation Detector of the AMS-02 Experiment

Max Planck Institute, Munich. January 10, Because of the concern about long-term silicon contamination of MDTs, we

Study of Mixed Gas Flow Pattern Inside RPC

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

BaBar Forward Endcap Upgrade

GAS ANALYSIS AND MONITORING SYSTEMS

Yoke Instrumentation: ILD Muon System / Tail Catcher. Valeri Saveliev IAM, RAS, Russia DESY, Germany 3 June, 2016

Development of small, easy to build and low gas consumming timing RPCs

PHENIX RPC in China. Xiaomei LI. Science and Technology on Nuclear Data Laboratory China Institute of Atomic Energy

On the possibilities for the readout of gas scintillation detectors for neutron scattering applications

A Reliable and Tracer Gas Independent Leak Detector for Food Packages

Design and Performance of the Vacuum Chambers for the Undulator of the VUV FEL at the TESLA Test Facility at DESY

Exradin Ion Chambers. What attributes make Exradin the smart choice? EXRADIN Ion Chambers

ISR workflow Tests status

Guideline for RMO Key comparison for Air kerma rate in 60 Co gamma radiation

TPC Report. D. Karlen T2K ND280m meeting December 7, 2004 Rome

MDT Status: Installation and Commissioning

1999 Microcomponents Technology SLYA017A

Victoreen B. Operators Manual. Image Intensifier Ion Chamber

A Longterm Aging Study of the Honeycomb Drift Tubes of HERA-B Using a Circulated and Purified CF -Gas Mixture

CHAPTER 4 PRE TREATMENT PATIENT SPECIFIC QUALITY ASSURANCE OF RAPIDARC PLANS

Only 8% to go. TOTAL 1494 of 1623 ACTIVE INSTITUTIONS (92%) May-09. May-04 Nov-04. May-07. Nov-02 May-03. Nov-05. Nov-06. Nov-07 May-08.

PERFORMANCE OF THE GAS GAIN MONITORING

STERILIZABLE DISSOLVED OXYGEN SENSORS

Reasons of Domestic Gas Meter Failures

Relative Dosimetry. Photons

Performance of the Liquid Hydrogen Target

Clinical Implementation of the TG-51 Protocol. David Followill Radiological Physics Center Houston Texas

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

Overview. Front Panel: Keypad and Display

Mitos Fluika Pressure and Vacuum Pumps Datasheet

GasSense NDIR User Manual

MANUAL KPS Pressure Control Valve

EUROPEAN LABORATORY FOR PARTICLE PHYSICS STUDY OF AGEING AND GAIN LIMITS OF MICROSTRIP GAS CHAMBERS AT HIGH RATES

GIF++ A New Gamma Irradiation Facility

Improve Process Reliability

Badan Jadrowych Nuclear Research Institute. Report INR No. 739/XIX/D CERN LIBRARIES, GENEVA CM-P Differential Recombination Chamber

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

GM Series Dual-Block Multi-Function Gas Control Valves

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

AC : ACCURATE CRYOCHAMBER FOR A SMALL LABORATORY WITH SMALL BUDGET

MIL-STD-883G METHOD

This test shall be carried out on all vehicles equipped with open type traction batteries.

WP2 Fire test for toxicity of fire effluents

Barrier Development and Evaluation Methodology. D.S. Musgrave 1 1 Thermal Visions, Inc., Granville, USA

USER'S GUIDE. Nanoflow Probe. Red Stripe. 3-4mm. ptfe Sleeve. To Injector. ZU1XC Fused Silica TTF115. Fused Silica. ptfe Sleeve

Supplementary Operator s Manual 42/24-14 EN Rev. 3

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

EXPERIMENTAL RESULTS OF GUIDED WAVE TRAVEL TIME TOMOGRAPHY

Advanced Test Equipment Rentals ATEC (2832) OMS 600

Porter Analytical & Industrial Products

Commissioning an IMRT System for MLC Delivery. Gary A. Ezzell., Ph.D. Mayo Clinic Scottsdale

Results of mathematical modelling the kinetics of gaseous exchange through small channels in micro dischargers

The FLUX-METER: implementation of a portable integrated instrumentation for the measurement of CO 2 and CH 4 diffuse flux from landfill soil cover.

Detecting sound wave of bubbles produced in a boiling liquid

Characteristics and Production of Gas Sealed, Radiation Hard, Small Ionization Chambers

Additives that prevent or reverse cathode aging in drift chambers with Helium-Isobutane gas *

Total Ionization Dose (TID) Test Results of the RH1028MW Ultralow Noise Precision High Speed Operational Low Dose Rate (LDR)

Vibration-Free Joule-Thomson Cryocoolers for Distributed Microcooling

Transmitter CS 21 Operation Manual

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use

Acoustic Emission Testing of The Shell 0f Electromagnetic Valve

TIGHTNESS. Glass sealing Thanks to our glass-sealing technology, ODU products can meet the most demanding tightness requirements.

Transmitter CS 21 Operation Manual

Constant Pressure Inlet (CCN) Operator Manual

Using PV Diagram Synchronized With the Valve Functioning to Increase the Efficiency on the Reciprocating Hermetic Compressors

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler

Drift-Chamber Gas System Controls Development for the CEBAF Large Acceptance Spectrometer

A REVIEW OF THE 2000 REVISIONS TO ANSI 2530/API MPMS 14.3/AGA REPORT NO. 3 - PART2 Paul J. LaNasa CPL & Associates

O3 3E 1 F Gas Sensor Module

TG-119 IMRT Commissioning Tests Instructions for Planning, Measurement, and Analysis Version 10/21/2009

HRLA High-Resolution Laterolog Array Tool. Improving the accuracy of Rt

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

LIQUID METER PROVING TECHNIQUES CT 4095

UK Opportunities in SiD Calorimetry

SPIRIT III Radiometer Saturation Effect

USER MANUAL. 1. Principle of operation. 2. Delivery condition. SPRING-LOADED SAFETY VALVES zarmak. Edition: 07/2016 Date: V (ex.

EFFECTS OF OUTGASSING FROM SOME MATERIALS ON GAS CHAMBER AGEING

628 Differential Pressure Decay Leak Tester

A4s Operation Manual

E X R A D I N Spherical Ion Chambers A3. A4 REF DOC #

Development of a High Pressure, Oil Free, Rolling Piston Compressor

PHOENIX L300i Best-in-class Helium Leak Detectors

RADIATION PROCEDURES MANUAL Procedure Cover Sheet

Dissolved Oxygen Guide

Transcription:

ATLAS RPC QA results at INFN Lecce M. Bianco,, I. Borjanovic, G. Cataldi, A. Cazzato,, G. Chiodini, M.R. Coluccia,, P. Creti, E. Gorini,, F. Grancagnolo, R. Perrino, M. Primavera, S. Spagnolo,, G. Tassielli,, and A. Ventura Dipartimento di Fisica - via Arnesano 731, Lecce - Italy INFN - via Arnesano 731, Lecce - Italy Abstract. The main results of the quality assurance tests performed on the Resistive Plate Chamber used by the ATLAS experiment at LHC as muon trigger chambers are reported and discussed. These are dark current, gas volume tomography, gas tightness, efficiency, and noise rate. Keywords: ATLAS, RPC, Quality Assurance, Cosmic ray test. PACS: PACS numbers: 29.4.Cs. INTRODUCTION Resistive Plate Chamber RPC [1] will be used as the muon trigger detector, in the barrel region of the ATLAS experiment at LHC [2]. A total number of 1116 RPC modules will be installed, for a total surface area of about 38 m 2. The extreme difficulty in accessing the ATLAS detectors, after installation is complete, imposes a high standard quality assurance for these modules. For this purpose three cosmic ray teststands have been built at INFN Napoli[3], Lecce [4], and Roma 2. Here, we report on the results from the Lecce site. ATLAS RPC MODULES In the ATLAS muon spectrometer a large variety of sizes and shapes of stations and, hence, RPC counters is foreseen. All counters, however, share the standard internal structure, described here in the following. A unit consists of a doublet of RPC detector layers enclosed in rigid lateral profiles and two support panels. A thin honeycomb-paper panel with aluminum skin separates the two layers realizing two independent Faraday cages. In figure [1] a cartoon of a RPC layer and a read-out panel are shown. A RPC layer contains a 2 mm thick active gas layer inside a planar bakelite gas volume ( 1 1 Ωcm) externally painted with graphite. The gas volume is surrounded by two pick-up strip panels segmented in two orthogonal views and separated by insulating plastic foils. The gas volume high voltage electrode is connected directly to the power supply, but the other one is connected to ground by a shunt resistor, in such a way that the dark current can be monitored. The RPC dimension can be as large as 4.8 m in one direction and 1.1 m in the other. Depending on the module size, a bakelite gas layer can consist of a single gas volume or of two adjacent gas volumes, and, most of the times, a read-out strip plane consists of

FIGURE 1. Drawing of ATLAS RPC layer (a) and read-out strip panel (b). two adjacent strip panels, instead of one. This results in modules which have 2 or 4 gas volumes and 4 or 8 read-out strip panels. QUALITY ASSURANCE PROCEDURE The quality control of the RPC chamber is accomplished with a series of accurate measurements and tests intended to verify the correctness of the assembly and detector performance. They represent the very first full chamber characterization and allow to extract statistical information useful to monitor the assembly line and give useful feedback for improvements. The quality control procedure consists of main certification tests and subsidiary control tests. The main tests regard leakage current versus high voltage curves, chamber efficiency and noise versus high voltage and front-end voltage threshold, and, finally, chamber 2D tomography. Instead, subsidiary control tests regard pulse test, gas volume leak test, front-end current absorption, and gas volume leakage current temporal drift. QUALITY ASSURANCE RESULTS Gas volume tests The radiation reliance and aging properties of the ATLAS RPC has been proven and carefully investigated at X5 gamma irradiation facility at CERN [5]. Nevertheless, the quality control of the gas volumes is crucial. The dark current versus high voltage curve is measured during the chamber conditioning and at the end of the tests. Gas volumes showing a dark current with a large ohmic or exponential part are rejected. In addition the dark current of each gas volume is monitored continuously to look for anomalous drift or current glitches (maybe due to local discharge or defective high voltage connectors). In figure [2] on the left the gas volume dark current distribution of ATLAS RPC tested in Lecce is shown at nominal conditions. On the same figure, on the right, is plotted the distribution of the difference between the high voltage power supply current and the gas volume current. From this plot is possible to infer a high level of electrical insulation

FIGURE 2. Gas volume dark current distribution (on the left) and power supply current and dark current difference distribution (on the right). The data are taken from the ATLAS RPC tested in Lecce with a high voltage of 1kV. FIGURE 3. Example of tomography plot of a small size gas volume with cut-out. The dark regular spot array are due to the spacers dead area. between gas volumes and other parts, such as mechanical supports and read-out strip panels ( 1GΩ). The 2D efficiency of each gas volume is measured with high accuracy and this is the most time consuming test which takes about 24 hours of running. The muon cosmic ray tomography is a very powerful tool to discover gas volume assembly defects (due for example to glue spots, badly glued spacers, and inner surface contaminations) which can compromise the aging performance of the unit. A noise rate 2D map is also taken, in order to exclude the presence of hot spots, which can become degenerative in the long term period. A gas volume tomography of a special unit is reported in figure [3]. This particular gas volume has a cut-out in order to leave room for the barrel toroid feet. Other special counters have gas volumes with cut-out for the alignment laser rays of the MDT precision muon chambers. Figure [3] shows that the high quality of the gas volumes is also achieved when shapes more complicated than the rectangular one are realized.

Strip panel efficiency Strip panel average cluster size Entries/.2 8 7 6 5 4 3 1.9.91.92.93.94.95.96.97.98.99 1 Efficiency Entries/.1 18 16 14 1 1 8 6 4 1 1.5 2 2.5 3 3.5 4 4.5 5 Cluster size FIGURE 4. Total efficiency distribution (on the left) and average cluster size distribution (on the right) for different high voltage values of 1kV (...), 1.1kV (.-.), and (-) 1.2 kv. The data are taken from the ATLAS RPC tested in Lecce with an equivalent input voltage threshold of about.5 mv. Gas tightness test, which is performed independently for each layer, consists in monitoring the differential pressure for about 2 hours, after imposing about 3 mbar of overpressure and closing the gas inlet and outlet. With our instrumental sensitivity of about 1 1 mbar we can reject modules with a gas leak larger than about 1 4 mbar s l. Read-out strip panel tests The read-out strip panel efficiency (given by the convolution of gas volume efficiency and strip panel electronic efficiency) is measured as a function of the applied high voltage and front-end voltage threshold. This allows to establish the detector working point and the parameter range where the chamber performs well. In figure [4] the distribution of the read-out strip panel efficiency (dead channels included) and the average cluster sizes (number of adjacent firing strips) are shown. The RPC counters have in average an efficiency greater than 97%, as expected by the detector active area coverage and required by the trigger design. The read-out strip panel noise rate is also measured at different high voltage and voltage threshold. In figure [5] the corresponding distribution is shown on the left. The average noise rate is less than 1 Hz, which is an order of magnitude smaller than the cm expected counting rate due to the photon 2 and neutron background in the ATLAS experiment at the designed LHC luminosity. In the same figure on the right, we reported the distribution of the ratio between the gas volume dark current (with the ohmic component subtracted) and the total strip panel noise rate. By assuming that the exponential part of the dark current is due to noise counts, we can estimate an average saturated avalanche charge of about 15 pc.

Entries/(.1Hz/cm2) Strip panel average noise rate 7 6 5 4 3 1 Entries/(2pC) Dark current - Noise ratio 7 6 5 4 3 1 1 2 3 4 5 6 7 8 9 1 Noise rate [Hz/cm2] 5 1 15 25 3 35 4 45 Igap/Noise[pC] FIGURE 5. Noise rate distribution (on the left) for different high voltage values of 1kV (...), 1.1kV (.-.), and (-) 1.2 kv. Current-to-Noise ratio distribution at a high voltage value of 1kV (on the right). The data are taken from the ATLAS RPC tested in Lecce with an equivalent input voltage threshold of about.5 mv. TABLE 1. RPC modules failure rate observed during QA tests in Lecce. Component failure Number of modules out of 272 Fraction of modules Readout strip panel 37 14% Gas volume spot 9 3.5% Gas volume high dark current 7 2.6% Gas leak 9 3.5% HV connector 2.9% Gas volume shunt resistor 3 1.3% Production components yield Table [1] reports the number of counters which failed the quality assurance test and the defective component responsible for the rejection. A rejection rate of about 6% is due to the gas volumes, which are discarded, 14% to the read-out panels, which are repaired, and, finally, 6% to assembly errors. Taking into account the number of components inside a module (we tested about strip panels and 1 gas volumes), we have a yield of 98.5% for gas volume and 98.3% for the strip panel (without considering the factory single component pre-selection). CONCLUSIONS The cosmic rays teststand for the ATLAS RPCs in Lecce is routinely in operation since July 4, and up to now, july 5, it has certified about 27 RPC modules, corresponding to about 25% of the ATLAS Muon Spectrometer. The test results and their statistical distributions show that the RPC properties are stable and uniform, satisfying the ATLAS experiment requirements. The end of the Quality Assurance Tests is foreseen

for the end of October 5. ACKNOWLEDGMENTS We thank R. Assiro, E.M. Fasanelli, G. Fiore, R. Gerardi, A. Miccoli, S. Podladkin and F. Ricciardi for the generous technical assistance they provide us in the construction and operational phase of the cosmic ray test-stand. REFERENCES 1. R. Santonico and R. Cardarelli, Nucl. Instrum. and Meth. 187, 377 (1981). 2. ATLAS detector and physics performance. Technical Design Report (May 1999). 3. M. Alviggi et al, Nucl. Instrum. and Meth. A518, 79 (4). 4. G. Cataldi et al., ATLAS RPC Cosmic ray Teststand at INFN Lecce - proceedings of XXIV Physics in Collision - Boston, June 27-29, 4. arxiv:physics/4975. 5. G. Aielli et al., Nucl. Instrum. and Meth. A 533, 98 (4).