LIFEPAK CR Plus DEFIBRILLATOR

Similar documents
LIFEPAK. CR2 Defibrillator. Better technology for better outcomes. Essential version

SAFETY MADE EASY. This is the face of confidence.

This is the face of confidence.

This is the face of confidence.

This is the face of confidence.

This is the face of confidence.

ACCESSORIES BROCHURE LIFEPAK 1000 DEFIBRILLATOR. Genuine Accessories from Physio-Control

Specifications - Powerheart G5 AED Fully Automatic / Semi Automatic Models

Powerheart G5 AED Automatic

ACCESSORIES LIFEPAK 500. Lifepak 500 Accessories

+ The AED shall have RescueCoach user paced voice instructions to guide the user through the rescue process.

MEDIANA HEARTON AED A15. Mediana Automated External Defibrillator A15

ACCESSORIES LIFEPAK CR AND LIFEPAK EXPRESS. Plus. for use with. for LIFEPAK CR Plus/LIFEPAK EXPRESS DEFIBRILLATORS

Warranty The device shall have a 6-year warranty at minimum

The Laerdal Range of Defibrillators. (This image represents the actual size of the HeartStart First Aid Model)

IN COMMERCIAL PROPERTIES

TrueCPR COACHING DEVICE PRODUCT BROCHURE

AED Plus. The Best Support For Rescuers

Better data means better CPR.

THE AED THAT LEADS THE WAY

TrueCPR COACHING DEVICE PRODUCT BROCHURE

AED Plus. The Best Support For Rescuers

2015 Guidelines Summary HeartSine samaritan PAD Automated External Defibrillators

Defibtech s Latest Advancement The Lifeline ARM Automated Chest Compression (ACC) Device for Professionals

Even Better Support For Rescuers

What is an AED? Why buy from defibshop?

AED Plus AL The Best Support For Rescuers

City of Pigeon Forge Fire Department Tony L. Watson, Chief

Even Better Support For. Professional Rescuers

ACCESSORIES LIFEPAK CR. Plus AND LIFEPAK EXPRESS AEDS. for use with. Genuine accessories from Physio-Control, a division of Medtronic.

AED Plus. The Best Support. For Rescuers

Even Better Support. For Rescuers

DESIGNED FOR PROFESSIONAL RESCUERS

AED Plus. The Best Support For Rescuers

Distinguishing Features

STARTERS GUIDE. Everything you need to know for: AED Purchase. CPR and AED Training. AED Compliance Management

What is an automated external defibrillator (AED)?

Once student shouts for help, instructor says, Here s the barrier device. I am going to get the AED. STOP TEST

Frequently Asked Questions About AEDs updated 11/2/2015

Confidence comes with knowing you are Code-Ready.

Instructions for Use

DEFIBRILLATOR PROGRAM POLICY

MONTGOMERY COUNTY PUBLIC SCHOOLS Office of the Chief Operating Officer Automated External Defibrillator (AED) Guidelines for High Schools

SEAL OF EXCELLENCE Henry Schein. emergency. & response. emergency & response defibrillators suction units ALL PRICES EXCLUDE VAT

LUCAS CHEST COMPRESSION SYSTEM PRODUCT BROCHURE

AED Trainer NF1200-T. Operator s Manual

Zoll AED Pro with CPR Stat-Padz & audio recording

Introducing Intellisense CPR Feedback Sensor and Technology Overview. Internal Use Only Not For Distribution

Bystander s bravery and action can rescue a life of victims. Guideline Training Course

Ohio Schools Automated External Defibrillation Program. Student Activity Center

AED Program. by Kelly Podsiedlik. October 8, Presented to: The 7 th Annual Florida Public Safety Institute Instructor Training Seminar

To help you understand about defibrillation and defibrillators (AEDs), we have put together a list of questions we get asked most often.

At the end of this course participants should be able to demonstrate:

Overview. The user must follow the instructions below.

HeartSine PAD 500P Trainer User Manual 1

Basic Life Support & Automated External Defibrillation Course. OBJECTIVES

Only Powerheart. Which of these AEDs fully self-test every day? Tested every day. Rescue Ready every day.

POLICY: EBBAA (453.11) Approved: September, 2002 Reviewed: January, 2003 Revised: February 23, 2004 Revised: August 18, 2015 DEFIBRILLATOR


Brevard County (Florida) Administrative Procedures

AED Plus Accessories and Training Products

European Resuscitation Council. Basic Life Support & Automated External Defibrillation Course

SKAGIT COUNTY AUTOMATED EXTERNAL DEFIBRILLATOR [AED] POLICY

Automated External Defibrillator (AED) Policy

Once student shouts for help, instructor says, Here s the barrier device. I am going to get the AED. STOP TEST

March 2018 FSN Medical Device Recall/Notification HeartStart FRx, HeartStart Home, and Heartstart OnSite AEDs

Advice and Best Practice Guidance for the use of Automated External Defibrillators (AED)

EMERGENCY MEDICAL RESPONSE ACTION PLAN FOR AUTOMATIC EXTERNAL DEFIBRILLATOR (AED) IN THE SCHOOL SETTING

Automated External Defibrillator Procedure. Cherry Burton Sportsfield

MANAGEMENT OF COLLAPSED ADULT PATIENT

Automated External Defibrillator (AED) Program PROCEDURES

City of Miami s Public Access Defibrillation Program

TFS AED Program. Revised 04/06/18 1

EMD CPR. The First First Responder. R. Darrell Nelson, MD, FACEP

World s Largest Automated External Defibrillator Source. the ULTIMATE AED. Buyer s Guide AEDSuperstore.com

Defibtech Automated External Defibrillator

Lifeline. Automated External Defibrillators (AED) The World s Easiest AEDs to Use

The Best Survival Tool. Occupational Health & Safety Magazine (June 2008) - by Chip Georges

A Guide to Implementing an AED. Program

EMD CPR. The First First Responder. R. Darrell Nelson, MD, FACEP. Emergency Medicine Wake Forest University Baptist Health

The University of Texas at Tyler. Automatic External Defibrillator Program

Fairfield Harbour Yacht Club (FHYC) Medical Emergency Response Plan (MERP): Basic Life Support and Automated External Defibrillator (AED)

Products and services, maximizing defibrillator performance

AED Plus. The Best Support. For Rescuers

AED AUTOMATED EXTERNAL DEFIBRILLATOR. Implementing an AED Program

Basic life support updates

SO THAT LIFE CAN GO ON

AED Plus Administrator s Guide

I have an AED, Now What??

STUDENTS AUTOMATED EXTERNAL DEFIBRILLATOR (AED) Pages 11

Administrative Procedures Automated External Defibrillator (AED)

HeartSine samaritan PAD. SAM 450P Trainer model TRN User Manual

COLUMBUS COUNTY SCHOOLS AUTOMATIC EXTERNAL DEFIBRILLATOR (AED) ADMINISTRATIVE PROCEDURES

A study comparing the usability of fully automatic versus semi-automatic defibrillation by untrained nursing students

Guidelines. Milan Special School District. Automated External Defibrillator (AED) Program

American Heart Association Health Care Provider CPR 2010 Curriculum

AED Program 2017 January 2017

Dynamic Automated External Defibrillator (AED) Registry

Cardiac Arrest General

Ten Mistakes. Every AED Program Manager Should Avoid

Transcription:

PRODUCT SHEET LIFEPAK CR Plus DEFIBRILLATOR Make Lifesaving Simple With over 50 years of innovation, a steadfast commitment to quality and a position as the global leader in defibrillation, Physio-Control brings you the LIFEPAK CR Plus automated external defibrillator. The CR Plus is designed specifically for the first person to respond to a victim of sudden cardiac arrest and incorporates the same trusted technology used by more EMS and hospital units around the world than any other brand. Although not everyone can be saved from sudden cardiac arrest, studies show that early defibrillation can dramatically improve survival rates. Simple to Use Simple to turn on Simple to find, remove and place electrodes correctly Simple to deliver therapy no shock button to push Simple to increase the chance for survival by automatically escalating energy up to 360 joules if needed* Simple to Own The CR Plus comes ready to use: Initial purchase includes carry case, extra electrodes, Charge-Pak battery charger and Ambu Res-Cue Mask Kit Lowest total cost of ongoing ownership in the AED industry Simple transition to EMS teams who also use LIFEPAK products Simple to Maintain One of the longest warranties in the industry at 8 years Synchronized Charge-Pak battery charger and electrode replacement cycle Simply put... The LIFEPAK CR Plus automated external defibrillator from Physio-Control is the effective, safe and affordable choice. AED users should be trained in CPR and the use of an AED. LIFEPAK AEDs require a prescription in the U.S. Please consult your physician.

SPECIFICATIONS Defibrillator Waveform: Biphasic truncated exponential, with voltage and current duration compensation for patient impedance.** Output Energy Sequence: Multiple levels, configurable from 150 joules to 360 joules (200 joules min for Japan). Factory default settings of 200J, 300J, 360J. Output Energy Accuracy: ±10% into 50 ohms, ±15% into 25 to 100 ohms. Shock Advisory System: An ECG analysis system that advises whether a shock is appropriate; meets rhythm recognition criteria specified in DF39. The device charges for shock only when the Shock Advisory System advises defibrillation. Device Capacity: Typical: Thirty (30) full discharges or 210 minutes of on time with a fully charged device. Minimum: Twenty (20) full discharges or 140 minutes of on time with a fully charged device. Shock Charge Time: Charge times with a fully charged device: 200 joules in less than 9 seconds, 360 joules in less than 15 seconds. System Recharge Times: Recharge times with a fully discharged device: Able to deliver 6 shocks or provide 42 minutes of operating time after 24 hours of recharge time and 20 shocks or 140 minutes of operating time after 72 hours of recharge time with a new CHARGE-PAK at temperatures above 15 C (59 F). Controls: Lid Release/ON-OFF Controls device power. Shock button (semi-automatic version) delivers defibrillation energy. After electrodes are attached to a patient, the fully automatic version of the device delivers a shock, if appropriate, not requiring operator intervention. Electrical Protection: Input protected against high voltage defibrillator pulses per IEC60601-1/EN60601-1. Safety Classification: Internally powered equipment. IEC60601-1/EN60601-1. Physical Characteristics Height: 10.7 cm (4.2 in). Width: 20.3 cm (8.0 in). Depth: 24.1 cm (9.5 in), excluding handle. Weight: 2.0 kg (4.5 lb) with CHARGE-PAK and electrodes User Interface User Interface: The user interface includes voice prompts, audible tones and graphic prompts. Readiness Display: The readiness display shows the device status. OK Indicator: Shows OK when the last self-test was completed successfully. When the OK indicator is visible, all other indicators are not visible. The OK indicator is not displayed during device operation. Charge-Pak Indicator: When displayed, replace the Charge-Pak battery charger. Attention Indicator: When first displayed, at least six (6) discharges or 42 minutes of operating time remain. Service Indicator: Service required when displayed. Environmental Note: All performance specifications defined assume the unit has been stored (two hours minimum) at operating temperature prior to operation. Operating Temperature: 0 to +50 C (+32 to +122 F). Storage Temperature: -40 to +70 C (-40 to +158 F) with Charge-Pak and electrodes, maximum exposure time limited to one week. Atmospheric Pressure: 760 mmhg to 429 mmhg, 0 to 15,000 feet above sea level. Relative Humidity: 5 to 95% (non-condensing). Water Resistance: IEC60529/EN60529 IPX4 Splash proof with electrodes connected, chargepak installed. Shock: MIL-STD-810E, Method 516.4, Procedure 1, (40g, 6-9 ms pulse, 1 /2 sine each axis). Vibration: MIL-STD-810E, Method 514.4, Helicopter - category 6 (3.75 Grms) and Ground Mobile - category 8 (2.85 Grms). Default Settings Energy Sequence: Energy sequence is set to 200J, 300J, 360J. Motion Detection: The motion detection system is set to on during analysis. Energy Protocol: The energy protocol is set to increase energy only after a lower energy shock was unsuccessful. Stack Shocks: Stack shocks option is set to off. Turn-On Prompt: The turn-on prompt is set to provide voice prompts upon power on. CPR Time: The CPR Time is set to 120 seconds. Voice Prompt Volume: The voice prompt volume is set to high. Accessories CHARGE-PAK Battery Charger Type: Li/SO2Cl2 Lithium Sulfuryl Chloride, 11.7V, 1.4 amp-hours. Replacement: Replace the CHARGE-PAK battery charger and QUIK-PAK electrodes packet after using the defibrillator, if the CHARGE-PAK symbol appears in the readiness display or when the Use By date is reached (typically 2 years). Weight: 80.5 grams (0.18 lb). QUIK-PAK Electrode Pads Pads: ECG is received from disposable defibrillation electrodes, standard placement (anterior-lateral). Pads Packaging: User intuitive, rapid release Quik-Pak electrodes allow the electrode pads to be preconnected to the device and protected under a top cover. Pads Replacement: Replace every two (2) years. Infant/Child Reduced Energy Defibrillation Electrodes: For use on infants and children less than 8 years of age or less than 55 lbs (25kg). Data Storage Memory Type: Internal digital memory. ECG Storage: Dual patient data storage. Minimum 20 minutes of ECG stored for the current patient, summarized data stored for the previous patient. Report Types: Continuous ECG A continuous patient ECG report. Continuous Summary report A summary of critical resuscitation events and ECG waveform segments associated with these events. Event Log report A report of time stamped markers, which reflect operator and device activity. Test Log report A device self-test activity report. Capacity: Minimum 200 time-stamped event log markers. Communications: Wireless transfer to a personal computer. Data Review: Physio-Control provides an array of tools to meet customer needs for data viewing and analysis. ** The specifications apply from 25 to 200 ohms. Voltage compensation is limited to the voltage that would result in delivery of 360 joules into 50 ohms. * Stiell IG, et al. Circulation 2007;115;1511-1517. All claims valid as of October 2012. All specifications are at 20 C unless otherwise stated. Physio-Control Headquarters Redmond, WA 98052 www.physio-control.com Customer Support P. O. Box 97006 Redmond, WA 98073 Toll free 800 442 1142 Fax 800 426 8049 Physio-Control Canada Physio-Control Canada Sales, Ltd. 7111 Syntex Drive, 3rd Floor Mississauga, ON L5N 8C3 Canada Toll free 800 895 5896 Fax 866 430 6115 Physio-Control, Inc., 11811 Willows Road NE, Redmond, WA 98052 USA 2013 Physio-Control, Inc. All names herein are trademarks or registered trademarks of their respective owners. Specifications subject to change without notice. GDR 3306953_G

SafeGuard Power System The unmatched technology of the SafeGuard Power System in the LIFEPAK CR Plus AED was designed to make device maintenance efficient, reliable and affordable. Cutaway view of the LIFEPAK CR Plus AED How it Works Many AEDs are powered by external batteries that lose capacity over time. The SafeGuard Power System offers a dual layer of security inside the CR Plus as the internal battery is kept to its optimal power level via the CHARGE-PAK battery charger. Benefits of the SafeGuard Power System The CR Plus comes with an internal, rechargeable battery that lasts the life of the product. The CHARGE-PAK battery charger and electrode replacement cycles are synchronized to expire on the same date, minimizing maintenance management. The CHARGE-PAK battery charger and electrode replacement kit are the lowest cost of any on the market. CHARGE-PAK battery charger Lifetime Internal Battery All claims valid as of December 2011.

For further information, please contact Physio-Control at 800.442.1142 (U.S.), 888.879.0977 (Canada) or visit our website at www.physio-control.com. Physio-Control Headquarters 11811 Willows Road NE Redmond, WA 98052 www.physio-control.com Customer Support P. O. Box 97006 Redmond, WA 98073 Toll Free 800 442 1142 Fax 800 426 8049 Physio-Control Canada Medtronic of Canada Ltd 6733 Kitimat Road Mississauga, ON L5N 1W3 Tel 888 879 0977 Fax 866 430 6115 Physio-Control, Inc., 11811 Willows Road NE, Redmond, WA 98052 USA 2011 Physio-Control, Inc. All rights reserved. GDR 3311115_A

Time to First Shock: The LIFEPAK CR Plus AED Advantage Designed to reduce delays in treatment Fully automatic AEDs help a rescuer deliver lifesaving therapy safely and quickly. But that is only part of the story. An AED must provide you with the easiest options for turning the device on, correctly placing the electrodes and delivering a shock. The LIFEPAK CR Plus AED is designed to make these three crucial steps quick and easy for all rescuers. 1. Easy to turn on The simple white arrow is designed to point users to the ON button, directing the rescuer to focus and push the button, automatically opening the lid and powering up the device. 2. Easy to find and place electrodes After powering the device on, the user is quickly prompted to pull the red handle away from the device which opens the electrode pouch. 3. Easy to deliver a shock Fully automatic AEDs have been shown to be safer than semi-automatic when used in the presence of bystanders. 1 A fully automatic AED helps rescuers to commit fewer errors than a semi-automatic AED 2 while eliminating the stressful step of physically pushing the shock button. Time to Shock: LIFEPAK CR Plus AED vs. ZOLL AED Plus 3 The CR Plus is designed to provide you with the easiest options for turning the device on, correctly placing electrodes and delivering a shock. In the study summarized below, only 50% of rescuers using the ZOLL AED Plus were successful at placing the electrodes, one of the crucial steps that CR Plus users were 100% successful in completing. Time Successful Completion LIFEPAK CR Plus AED ZOLL AED Plus LIFEPAK CR Plus AED ZOLL AED Plus Device On ~20 sec >50 sec Data not available Data not available Place Electrodes ~70 sec >200 sec 100% 50% Shock (Semi-automatic) 93 sec 210 sec 100% 44% Saving two minutes in time to first shock could mean up to 20% increase in chance of survival. 4 0 1 2 3 4 Time to Shock (minutes) 1:33 3:30

References 1 Hosmans T, Maquoia I, Vogels C, et al. Manikin and simulation study: Safety of fully automatic external defibrillation by untrained lay rescuers in the presence of a bystander. Resuscitation. 2008;77:216-219. 2 Monsieurs KG, Vogels C, Bossaert LL, et al. A study comparing the usability of fully automatic versus semi-automatic defibrillation by untrained nursing students. Resuscitation. 2005;64:41 47. 3 Andre A, Jorgenson B, Froman J, et al. Automated External Defibrillator Use By Untrained Bystanders. Prehospital Emergency Care. 2004;8:284-291. 4 Cummins RO. 1989. From concept to standard-of-care? Review of the clinical experience with automated external defibrillators. Annals of Emergency Medicine. 18:1269-75. LIFEPAK AEDs require a prescription in the U.S. Please consult your physician. AED users should be trained in CPR and in the use of the AED. For further information, please contact Physio-Control at 800.442.1142 (U.S.), 800.895.5896 (Canada) or visit our website at www.physio-control.com. Physio-Control Headquarters 11811 Willows Road NE Redmond, WA 98052 www.physio-control.com Customer Support P. O. Box 97006 Redmond, WA 98073 Toll free 800 442 1142 Fax 800 426 8049 Physio-Control Canada Physio-Control Canada Sales, Ltd. 7111 Syntex Drive, 3rd Floor Mississauga, ON L5N 8C3 Canada Info.canada@physio-control.com Toll free 800 895 5896 Fax 866 430 6115 Physio-Control, Inc., 11811 Willows Road NE, Redmond, WA 98052 USA 2013 Physio-Control, Inc. All names herein are trademarks or registered trademarks of their respective owners. GDR 3315615_A

Improving Shock Success Each year, more than 300,000 people die from Sudden Cardiac Arrest (SCA). More people die from SCA than breast cancer, lung cancer and AIDS combined. 1 Unfortunately, those who experience a witnessed SCA have a very low chance of survival the national average is about 5%. Early defibrillation can play a critical role in survival. Shock success during this stage can be influenced by a number of important factors, including improving time to first shock, reducing CPR pauses, and the availability of higher levels of energy. Improving Time to First Shock Although not everyone can be saved from sudden cardiac arrest, studies show that early defibrillation can dramatically improve survival rates. Early defibrillation combined with CPR can improve survival rates to as high as 74% when defibrillation is provided within three minutes of collapse. 2 For every minute that elapses between sudden cardiac arrest and defibrillation, the chance of survival decreases 7 to 10%. 3 Many factors influence time to first shock, including determining an AED is needed, retrieving the AED, turning the AED on, applying the pads, and then delivering a shock. Determining an AED is needed and retrieving an AED can vary based on the event and location. However, the time between device retrieval and first shock is largely influenced by the AED used. Usability studies have shown that AEDs differ dramatically in their ease of use and subsequent time to first shock. In a study of untrained bystanders, Dr. Andre et al. found the LIFEPAK CR Plus AED had the shortest average time to shock of four leading AEDs studied. 4 Time to shock was defined as the time rescuers entered the room until the time a shock was delivered. Other AEDs had considerably longer average time to shock intervals. Physio-Control LIFEPAK CR Plus AED Philips Heartstart Onsite Cardiac Science PowerHeart G3 Plus ZOLL AED Plus Time to Shock (sec) 93 99 132 210 The goal of public access defibrillation (PAD) programs is to reduce time between onset of SCA and shock delivery. A general rule of thumb for PAD programs is to place AEDs within three minutes of locations where cardiac arrests are likely to occur. Assuming it takes three minutes to retrieve an AED, we can predict the following time to first shock using the data from the Andre study. % Success 100 80 60 40 20 0 Retrieve AED 1 2 3 4 5 6 7 8 9 10 Time (minutes) Shock success over time 2 Reducing CPR Pauses Apply AED & Shock Success rates decrease 7 10% each minute LIFEPAK CR Plus AED HeartStart Onsite PowerHeart G3 Plus AED Plus Minimizing pre-shock pauses in CPR improves the chances of shock success and patient survival. 5 There are a number of AED design features that can influence pre-shock CPR pauses, including: Reducing the time required for analysis and charging. Eliminating the need to push the shock button. The LIFEPAK CR Plus AED is one of the few fully automatic AEDs available. A fully automatic AED will give a shock automatically, if needed, without the rescuer having to push a button to deliver that shock. This type of AED is designed to help responders who may hesitate in cardiac arrest emergencies. Enabling a pre-shock CPR interval. The LIFEPAK 1000 Defibrillator is the only AED available that offers unique cprmax technology, allowing you to provide compressions until the moment of shock. Availability of Higher Energy Levels Clinical data suggests that higher energy levels are associated with higher shock success rates. 6 360 joule (J) biphasic defibrillators have successfully resuscitated patients that were not resuscitated by

other defibrillators with energy limited to 200J. The FDA is investigating 14 reports of events in which a 200J biphasic defibrillator was ineffective and a subsequent shock from a different 360J biphasic defibrillator resulted in immediate defibrillation/cardioversion. All Physio-Control defibrillators deliver a full range of energy up to 360J the most energy available in the industry today. The End Result The LIFEPAK CR Plus AED compares favorably against the competition on a number of key features associated with improved shock success and higher survival, including time to first shock, reduced CPR pauses, and availability of a higher level of energy. Investing in an AED program is a commitment to protect the lives of those in your community. Why not invest in the best? References 1. Sudden Cardiac Arrest Association. Sudden Cardiac Arrest Facts. May 2011. http://associationdatabase.com/aws/scaa/asset_manager/get_file/6068/sudden_cardiac_arrest_fact_sheet.pdf 2. Valenzuela T.D. et al. Outcomes of rapid defibrillation by security officers after cardiac arrest in casinos. New England Journal of Medicine. 2000; 343:1206-1209. 3. Cummins R.O. 1989. From concept to standard-of-care? Review of the clinical experience with automated external defibrillators. Annals of Emergency Medicine. 18:1269-75. 4. Andre AD, et al. Automated External Defibrillator Use By Untrained Bystanders: Can the Public Model Work? Prehospital Emergency Care. 2004; 8:284-291. 5. 2010 American Heart Association Guidelines for CPR and ECC, Volume 122, Issue 18_suppl_3; November 2, 2010; S641. 6. Stiell IG, et al. The BIPHASIC Trial: A randomized comparison of fixed lower versus escalating higher energy levels for defibrillation in out-of-hospital cardiac arrest. Circulation. 2007; 115:1511-1517. AED users should be trained in CPR and use of the AED. LIFEPAK AEDs require a prescription. Please consult your physician. All information including comparative statements are valid as of March 2013. For further information, please contact Physio-Control at 800.442.1142 (U.S.), 800.895.5896 (Canada) or visit our website at www.physio-control.com Physio-Control Headquarters 11811 Willows Road NE Redmond, WA 98052 www.physio-control.com Customer Support P. O. Box 97006 Redmond, WA 98073 Toll free 800 442 1142 Fax 800 426 8049 Physio-Control Canada Physio-Control Canada Sales, Ltd. 7111 Syntex Drive, 3rd Floor Mississauga, ON L5N 8C3 Canada Toll free 800 895 5896 Fax 866 430 6115 Physio-Control, Inc., 11811 Willows Road NE, Redmond, WA 98052 USA 2013 Physio-Control, Inc. All names herein are trademarks or registered trademarks of their respective owners. GDR 3309485_B

Water Protection Test All Automatic External Defibrillators (AEDs) have an IEC 529 Ingress Protection (IP) rating for water protection. The more vigorous the testing method, the higher the rating earned and the more durable the product in wet conditions. Below is a comparison between the water protection rating method for Philips HeartStart OnSite * and the Physio-Control LIFEPAK CR Plus AED. Philips HeartStart OnSite Defibrillator, IPX1 x Physio-Control LIFEPAK CR Plus AED, IPX4 Spray Head Rotates a Full 180 Area of Coverage Area of Coverage Device Rotates 360 Figure 1. IPX1 Test Method Figure 2. IPX4 Test Method IPX1 Test Method Water is dripped on the top of the defibrillator for 10 minutes to achieve IPX1 rating for Philips HeartStart OnSite AED. Only the upper areas of the device are exposed to vertical falling drops of water. Parts may be susceptible to water penetration from different angles. IPX1 is generally accepted as the minimum standard for defibrillators used indoors. IPX4 Test Method Water is sprayed in all directions for five minutes to achieve IPX4 rating for LIFEPAK CR Plus AED. Much more stringent and demanding than IPX1. All areas from top to bottom are completely exposed to water penetration from all angles. Simulates being in a heavy, driving rainstorm. * Philips HeartStart OnSIte Defibrillator brochure dated Jan 2007, posted on website as of March 2010

Although not everyone can be saved, studies show that early defibrillation can dramatically improve survival rates. AED users should be trained in CPR and the use of an AED. LIKEPAK AEDs require a prescription. Please consult your physician. For further information, please contact Physio-Control at 800.442.1142 (U.S.), 888.879.0977 (Canada) or visit our website at www.physio-control.com. Physio-Control Headquarters 11811 Willows Road NE Redmond, WA 98052 www.physio-control.com Customer Support P. O. Box 97006 Redmond, WA 98073 Toll Free 800 442 1142 Fax 800 426 8049 Physio-Control Canada Medtronic of Canada Ltd 99 Hereford Street Brampton, ON L6Y 0R3 Tel 888 879 0977 Fax 866 430 6115 Physio-Control, Inc., 11811 Willows Road NE, Redmond, WA 98052 USA 2010 Physio-Control, Inc. All rights reserved. All names herein are trademarks or registered trademarks of their respective owners. Specifications subject to change without notice. Not all products available worldwide. Please contact your local sales representative for a list of approved products in your region. GDR 3306046_A