Subject: Progress Report CLIN 0001AB, SBIR Topic No. N Legged Vehicle for Underwater Mobile Operations

Similar documents
Lamprey Robots 12. Joseph Ayers, Cricket Wilbur, Chris Olcott Northeastern University Marine Science Center East Point, Nahant, MA USA

REPORT DOCUMENTATION PAGE

Computer Aided Drafting, Design and Manufacturing Volume 26, Number 2, June 2016, Page 53. The design of exoskeleton lower limbs rehabilitation robot

Robot motion by simultaneously wheel and leg propulsion


Design, Fabrication and Analysis of Microcontroller Based Bipedal Walking Robot Vaidyanathan.V.T 1 and Sivaramakrishnan.R 2

Toward a Human-like Biped Robot with Compliant Legs

SCHEINWORKS Measuring and Analysis Systems by

Decentralized Autonomous Control of a Myriapod Locomotion Robot

LOCOMOTION CONTROL CYCLES ADAPTED FOR DISABILITIES IN HEXAPOD ROBOTS

In memory of Dr. Kevin P. Granata, my graduate advisor, who was killed protecting others on the morning of April 16, 2007.

ME 8843-Advanced Mechatronics. Project Proposal-Automatic Bike Transmission

Keywords--Bio-Robots, Walking Robots, Locomotion and Stability Controlled Gait.

First Experimental investigations on Wheel- Walking for improving Triple-Bogie rover locomotion performances

Dynamically stepping over large obstacle utilizing PSO optimization in the B4LC system

Datalogging Shirt for Baseball Pitchers

GOLFER. The Golf Putting Robot

A Bio-inspired Behavior Based Bipedal Locomotion Control B4LC Method for Bipedal Upslope Walking

Body Stabilization of PDW toward Humanoid Walking

Sensing and Modeling of Terrain Features using Crawling Robots

Transformation of nonfunctional spinal circuits into functional states after the loss of brain input

Walking Simulator Mechanism

Robotics and Autonomous Systems

Robotics and Autonomous Systems

Controlling Walking Behavior of Passive Dynamic Walker utilizing Passive Joint Compliance

Written Report of Robot Design

Using sensory feedback to improve locomotion performance of the salamander robot in different environments

Designing Diving Beetle Inspired Underwater Robot(D.BeeBot)

Efficient Gait Generation using Reinforcement Learning

THE PRESSURE SIGNAL CALIBRATION TECHNOLOGY OF THE COMPREHENSIVE TEST

Biomechanical analysis of the medalists in the 10,000 metres at the 2007 World Championships in Athletics

American made since 1954

Software Design of the Stiquito Micro Robot

Neurorehabil Neural Repair Oct 23. [Epub ahead of print]

PERCEPTIVE ROBOT MOVING IN 3D WORLD. D.E- Okhotsimsky, A.K. Platonov USSR

The Kinematics Analysis of Wu Yibing's Tennis Forehand Technique Xin WEN, Ji-he ZHOU and Chuan-jia DU

Simulation of the Hybtor Robot

Using GPOPS-II to optimize sum of squared torques of a double pendulum as a prosthesis leg. Abstract

YAN GU. Assistant Professor, University of Massachusetts Lowell. Frederick N. Andrews Fellowship, Graduate School, Purdue University ( )

The Incremental Evolution of Gaits for Hexapod Robots

Module 3 Developing Timing Plans for Efficient Intersection Operations During Moderate Traffic Volume Conditions

Design and Modeling of a Mobile Robot

Biomechanics and Models of Locomotion

Motion Control of a Bipedal Walking Robot

A bit of background. Session Schedule 3:00-3:10: Introduction & session overview. Overarching research theme: CPTA

Generating Arachnid Robot Gaits with Cyclic Genetic Algorithms

D-Case Modeling Guide for Target System

C-Brace Reimbursement Guide

Project Title: Pneumatic Exercise Machine

Computer Integrated Manufacturing (PLTW) TEKS/LINKS Student Objectives One Credit

Laboratory 2(a): Interfacing WiiMote. Authors: Jeff C. Jensen (National Instruments) Trung N. Tran (National Instruments)

CHAPTER IV FINITE ELEMENT ANALYSIS OF THE KNEE JOINT WITHOUT A MEDICAL IMPLANT

Development of Fish type Robot based on the Analysis of Swimming Motion of Bluefin Tuna Comparison between Tuna-type Fin and Rectangular Fin -

Experiment of a new style oscillating water column device of wave energy converter

IEEE RAS Micro/Nano Robotics & Automation (MNRA) Technical Committee Mobile Microrobotics Challenge 2016

Design of Altitude Measurement System for Aerospace Applications (Digital Barometric Altimeter)

Supplementary Figures

Walking with coffee: when and why coffee spills

Distributed Control Systems

Kungl Tekniska Högskolan

Centre for Autonomous Systems

Microprocessor Technology in Ankle Prosthetics

Sample Solution for Problem 1.a

Introduction to Robotics for 3D Additive Construction

Development of Low Volume Shape Memory Alloy Variable Ballast System for AUV Use

Rogue Wave Statistics and Dynamics Using Large-Scale Direct Simulations

Equine Cannon Angle System

Using SolidWorks & CFD to Create The Next Generation Airlocks

METHODOLOGY. Signalized Intersection Average Control Delay (sec/veh)

KOTARO SASAKI Curriculum Vitae

Examples of Carter Corrected DBDB-V Applied to Acoustic Propagation Modeling

1. A tendency to roll or heel when turning (a known and typically constant disturbance) 2. Motion induced by surface waves of certain frequencies.

Walking Experiment of Biped Robot with Antagonistic Actuation Using Non-Linear Spring

Improvement of the Cheetah Locomotion Control

Static Extended Trailing Edge for Lift Enhancement: Experimental and Computational Studies

Project Number: P14474

Experimental Investigation of Dynamic Load Control Strategies using Active Microflaps on Wind Turbine Blades.

Wind turbine Varying blade length with wind speed

From Passive to Active Dynamic 3D Bipedal Walking - An Evolutionary Approach -

Analysis and realization of synchronized swimming in URWPGSim2D

How Do You Swing? You should be working with new lab partners starting with this lab.

Open Research Online The Open University s repository of research publications and other research outputs

Available online at ScienceDirect. Procedia Engineering 112 (2015 )

A Neuromuscular Model of Human Locomotion and its Applications to Robotic Devices

BUILDING A BETTER PASSIVE WALKER

Marine Mammal Acoustic Tracking from Adapting HARP Technologies

ZMP Trajectory Generation for Reduced Trunk Motions of Biped Robots

Mobile Robots (Legged) (Take class notes)

Complex movement patterns of a bipedal walk

CS 4649/7649 Robot Intelligence: Planning

The Future of Hydraulic Control in Water-Systems

Kenzo Nonami Ranjit Kumar Barai Addie Irawan Mohd Razali Daud. Hydraulically Actuated Hexapod Robots. Design, Implementation. and Control.

Vibration Analysis and Test of Backup Roll in Temper Mill

Evolving Gaits for the Lynxmotion Hexapod II Robot

Overview. 2 Module 13: Advanced Data Processing

E.I. Kugushev, 7.6. Jaroshevskij Institute of Applied Mathematics, the USSR Academy of Sciences, Moscow, A-47, Miusskaya Sq», 4

REPRESENTATION OF HUMAN GAIT TRAJECTORY THROUGH TEMPOROSPATIAL IMAGE MODELLING

Center of Mass Acceleration as a Surrogate for Force Production After Spinal Cord Injury Effects of Inclined Treadmill Walking

New Techniques for Recording Data from an Operating Scotch Yoke Mechanism

USING COMPUTERIZED WORKFLOW SIMULATIONS TO ASSESS THE FEASIBILITY OF WHOLE SLIDE IMAGING: FULL ADOPTION IN A HIGH VOLUME HISTOLOGY LABORATORY

Transcription:

FAX. 617-740-20C5 ptwx 710-348-6932 TEL. 617-749-4800 Massa Products Corporation' 280 Lincoln Street, Hingham. MA 02043-1796 VIA CERTIFIED MAIL RETURN RECEIPT REQUESTED, REPLY REFER TO September 15, 1994 F Scientific Officer.1 m Office of Naval Research 0U 800 North Quincy Street 0. M Arlington, VA 22217-5660 -I--qI n -Attention: Thomas McKenna Reference: Contract N00014-94-C-0078 Subject: Progress Report CLIN 0001AB, SBIR Topic No. N93-139 Legged Vehicle for Underwater Mobile Operations Encl. (1): Progress Report, Prof. Joseph Ayers, Northeastern Univ. Gentlemen: This letter report summarizes the status of the subject contract. Since the last progress report work has been proceeding both at Northeastern University and Massa Products Corporation. Professor Ayers at Northeastern's Marine Science Center has been continuing his improvements on the ambulation controller for the robot, analyzing rheotaxic behavior and performing analysis of gate patterns underlying walking in the lateral and backward direction. A summary of his work is contained in the memorandum of Encl. 1. A great deal of work has been done both by Massa engineers and Jim Jalbert at Northeastern's Marine Systems Engineering Laboratory on analyzing Nitinol to determine how it can be best utilized as an actuator for the robot. The effort to characterize the Nitinol to determine how best to utilize it as an actuator has taken much more time and effort than originally anticipated. Jim Jalbert at Northeastern has been working on the problem associated with attaching lead wires to the Nitinol. Crimping can cause 0 fatigue on the wire, and overheating from soldering can cause the Nitinol to 00 loose some of its properties. He has found that using a wire-wrap gun may lead to a technique in which a piece of solid wire can be attached to the 63-d Nitinol. He is also investigating utilization of small strain gauges with a Nitinol actuator and the use of micro-thermal couples to determine the temperature of the wire. J ýj Massa's engineering effort has focused on investigating Nitinol, and aii- building a mechanism to demonstrate the control of three muscle pairs to perform walking motions under the control of the computer program developed by Professor Ayers that is based on the neural outputs produced by the Slobster during ambulation. Several leg-like structures have been built, but - ts there have been problems in connecting the Nitinol so that large numbers of cycles can be operated without fatigue and with proper controls of heating land cooling the actuators. In parallel, a large number of experiments have been conducted to determine how best to drive the Nitinol with electric currents to heat it and then how best to cool it to allow it to return to its original length. This work is still progressing. 94 9 2 1 0of4... Over a Gener n of Outstanding Leadership in Electroacoustics

Massad Products Corporation N00014-94-C-0078-2- September 15, 1994 CDRL A001AB Because of some potential problems that may exist with Nitinol as a final actuator in a practical robot because of concerns with controlling its heating and cooling and final power requirements, Massa engineers have been investigating the possibilities of utilizing other actuators such as motors. Conceptual systems are being developed that will allow these actuators to run from the same computer program Protessor Ayers has developed which mimics the neural outputs of the lobster during ambulation. Because final mechanical leg design concepts can not be efficiently developed until a final actuator is selected and the method of controlling that actuator is determined, Massa has not proceeded with any production engineering concepts associated with the final leg design. In addition, operating a single leg in air adds a significant complexity due to gravitational forces which does not exist in an ambulatory robot for use underwater. Therefore, Massa plans to prove the feasibility of the controller concepts during Phase I by building three muscle pairs using Nitinol as the actuator. These three muscle pair will represent the six muscles that control the movement of the three joints in the lobster leg during ambulation. Massa then plans to develop a control circuit that will take the signals from Professor Ayers computer program and drive the three muscle pair to show coordinated movement of the joints during ambulation. This will prove the viability of the system without the need to fabricate an actual mechanical leg. Some muscle pairs will also be fabricated utilizing other actuator technologies. Because the decision on a practical actuator must be made before a final leg is designed, and because this decision is going to require a larger scope of work than is called for during the Phase I effort, it is proposed by Massa that this decision would not be made until the initial period of the Phase II effort of this program. Professor Crisman at Northeastern University's Robotics and Vision Systems Laboratory has been continuing her work on the simulation program. Because of the longer than expected time that has been spent on trying to characterize the Nitinol, she has not been able to input Nitinol actuators into her simulation. Sincerely, MASSA PRODUCTS CORPORATION Accesion For Donald P. Massa NTIS CRA&I President DTIC TAB 0 Unannou,,ced [ cc: Administrative Contracting Officer Justification Office of Naval Research _;._---- 800 North Quincy Street Arlington, VA 22217-5660 By... Oistidbr'ic, DPM/cb Director, Attn: Code 2627 Naval Research laboratory Washington, DC 20375 or Defense Technical Information Center Building 5, Cameron Station Alexandria, VA 22304-6145

'EP" L3 '94 14:25 FRO tarine SCIENCE CENTER ( PAGE.002 Memorandum To: Don Massa From: Joseph Ayers Date: September 8, 1994 Re: Ambulatory Robot Interim Progress Report I Development of Ambulation Controller I have continued development of the biologically based ambulation controller to begin implementation of integrated behaviors with the goal of establishing current and surge adaptations, navigation, compensatory reflexes to gravity and searching. The following new modules have been implemented: *AntiGravity Recruiter - Allows recruitment of depressor for pitch and roll compensation. *Sensor Objects - I have integrated a new data structure which corresponds to the labeled-lines of crustacean sensors *Sequencer - We have implemented queue structure for sequencing components of behaviors such as reflexes, modal actions patterns and goal oriented behaviors. It is essential for the implementation of complex behaviors such as searching, rheotaxis, etc. *Modal Action Patterns - I have continued implementation of modal action pattern objects and conversion of all command elements to modal objects. *Goal Achieving Behavior - I am implementing software objects to mediate goal achieving behavior necessary for searching. In addition, We are examining small microcontroller platforms to which we will transfer our existing Mac based development system. Prime candidates are the Pic 8 bit Microcontroller and the Onset Model 8 microcontroller system. Enclosure / to Massa Letter Dated.

i) ( SEP 6 '94 14:2S FROM MARINE SCIENCE CENTER PAGE.O03 Analysis of Rheotaxic Behavior Lars Schlichting and I are continuing analysis of water current and surge compensation in lobsters and have performed extensive video analysis. Tasks performed to date include: 'Motion Analysis Extensions to Colorlmage: I have added software objects to my motion analysis program ColorImage necessary for the complex reverse kinematic analysis of rheotaxic behavior. In particular, I implemented a set of algorithms for acquisition of complex display lists. The program now allows one to input up to 15 angles, positions or distances between two points for each of the frames of a video. The results are saved in a table file where the first column is the time of each frame and the subsequent columns are the measured parameters 'Video Analysis Performed: We have performed a rather complete video analysis of lobster responses to different laminar flow velocities and surge on our laminar flow and wave surge tanks. At present we have 7 2 hour videos which we are cataloging with our video data-base system and subjecting to kinematic analysis with ColorImage. 'Kinematic analysis in progress: *Two dimensional (pitch and yaw) carapace trajectories during turns -Forward load compensation strategies during laminar flow at different velocities. *Contralateral Coordination during turns Gait Analysis In Progress We are presently performing analysis of the gait patterns underlying walking in the lateral and backward directions which are at present poorly characterized. *Lobster Treadmill Implemented: We have resurrected my original lobster treadmill which I developed at the University of California in the '70s and have developed a new walking balance which will permit us to shift from forward and backward walking to lateral walking. 'Multi-Leg Movement Transducer Developed: Al Badger has completed the 8 leg movement transducer. During forward and backward walking the system can monitor the protraction (swing phase of forward walking) and retraction (stance phase) movements of the limbs. During lateral walking the system monitors the extension and flexion movement. We are currently 2

iep 1 '94 14-2S FRO. IARINE SCIENCE CENTER - PAGE.004 performing experiments to establish the relationship between the gait pattems and walking speed for the four walking directions. We record these movements with our SuperScope digital oscilloscope program are developing software instruments which will automaticaly quantify the intersegmental and contralateral phase lags/latencies for forward, backward, lateral leading and lateral trailing walking. 3