PRESSURE TESTING REPORT

Similar documents
North American sealing solutions Bridge Plug Ball Drop Frac Plug Caged Ball Frac Plug

Bridge Plugs, Ball Drop & Caged Ball Plugs For Zone Isolation

31 st Gas-Lift Workshop

HPHT Annular Casing Packer. Obex Annular Casing Packer

Perforating Options Currently Available in Horizontal Shale Oil and Gas Wells. Kerry Daly, Global BD Manager- DST TCP

REV0709. Parts List. Hydraulic Cylinder Model MODEL C SINGLE-ACTING, SPRING RETURN HYDRAULIC CYLINDER. Max. Capacity: 55.2 Tons at 10,000 PSI

Instruction sheet for Hydraulic Cylinder

Air Mortar User Manual

Hydrostatic Pressure Testing

MANUAL BE SERIES Test Benches

AUTOMATIC VAPOR PRESSURE TESTER REID METHOD, DEMI SIZE MODEL AVP-30 INSTRUCTION MANUAL. Rev

Manual. Bypass Feeder. Installation Maintenance Repair Manual. Chemical Addition and Filtering

2. Determine how the mass transfer rate is affected by gas flow rate and liquid flow rate.

Hydraulic Piston Accumulators

Disposal/Injection Well Pressure Test Report (H-5)

EP WELLS DAILY OPERATIONS REPORT Report 29 05/19/2017

Beamex PG PRESSURE GENERATORS. Beamex PGM PGV PGC PGHH PGPH PGL

KJ4000 Operating Instructions & Parts Manual NSN

DB Bridge Plug. Features. Benefits. Applications

Genie Supreme TM Model 123HP Installation & Operation Instructions

CO2 Tank Conversion Kit P.N , P.N , and P.N

Genie Supreme Model 123 Installation & Operation Instructions

INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

SCORPION HIGH-QUALITY, FULLY COMPOSITE PLUGS

GREIG FILTERS, INC. OPERATION MANUAL

NGP-250/500 Nitrogen Generator Quick Start Guide

On-Off Connector Skirt

WW-720. Pressure Reducing Control Valve

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS

VLI Visible Level Interface Operation & Maintenance Manual

Aging Cell, OFITE Style. Included Items

Technical Service Bulletin May 2017 TSB

V5197A. Firing Rate Gas Valve APPLICATION FEATURES PRODUCT HANDBOOK

Installing ASI Umbilical Delivery Systems

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

REL-46 WARNING NOTICE 15 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD. Compatible with RELIABLE R15 and P Style dies. REL-46 Manual

Testing Procedures & Trouble Shooting Guide Reduced Pressure Zone Assembly (1/2, 3/4", 1, 1 1/4, 1 1/2" & 2 )


Winter Shut Down Procedure

Hydraulic Reliability & Preventive Maintenance Report

Hydro-Mech Bridge Plug

TECHNICAL DATA. than the water inlet pressure to the concentrate

RG1200 Service and Repair Manual

PMI Advanced Automated. Pulse Decay Permeameter APDP-10K-HP-101. Not just products... Solutions!

Pressure reducing valve, pilot operated, Model 3DR

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Fixed Displacement Motor A4FM

Instruction Manual. Maximum Operating Pressure 1,500 bar

LAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12)

Installation, operating and maintenance Instructions for Seemag bypass level indicator

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

Wellwork Chronological Regulatory Report

G250/G250 HP Compatibility of Upgrade Kit

Retrievable Bridge Plugs

CASH VALVE TYPE KP BACK PRESSURE VALVES

Smart Water Application Technologies (SWAT) TM

Model A Sleeve Valve Cement Retainer

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

Operation and Maintenance Instructions

ALF400 to 900, ALT-5/-9

FOR TM TURRET COMBAT ENGINEER VEHICLE, M728 ( ) TECHNICAL MANUAL

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

Model 420-HY Pressure Regulating Hydrant Valve

WW-720. Pressure Reducing Control Valve

NeoProducts, LLC 1201 Dealers Ave. Harahan, LA Ph:

COSASCO 6000 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE

GM Series Dual-Block Multi-Function Gas Control Valves

All information correct as of 29 nd August 2013 and subject to change without notice CORRECT AS OF

Section I. As You Begin:

IWCF Equipment Sample Questions (Surface Stack)

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

IP16 HYDRAULIC INTENSIFIER. Safety, Operation and Maintenance Stanley Black & Decker, Inc. New Britain, CT U.S.A /2011 Ver.

Inverse Prop. Pressure-Relief Cart., Size 2 4

Float Operated Level Controllers

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

ELECTRONIC PLC SERIES Test Benches

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

OPERATING MANUAL DOUBLE ACTING DRILLING INTENSIFIER HYDRAULIC TYPE

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

PRESSURE TEST PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model No: PTP100. Part No: GC01/09

1305 Series Pressure Reducing Regulators

Operating Instructions VETTER Industrial Lifting Bags 8 bar - Type IKV

IFTGS14 Ball Float Steam Trap ½" and ¾" with Integral Spiratec Sensor

Instruction & Parts Manual

VB-7212 Series. Application. Features. Applicable Literature. 5/8" O.D., 45 SAE Flared Stem Up Open, Two-Way Valves General Instructions

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

Tex-914-K, Calibrating Motorized Gyratory-Shear Molding Asphalt Press

Powers Controls D Day-Night Thermostats

BS12N Piezoresistive OEM Pressure Sensor

REFER TO AQUATHERM TECHNICAL BULLETIN A-AQTTB FOR ADDITIONAL INFORMATION AND SAFETY PRECAUTIONS

OFI Testing Equipment - Aging Cell Instructions Page 1 of 4. Instructions OFITE AGING CELLS

Operating Instructions Part No

Operating Instructions Models 36200, , 46200, Hydrostatic Test Pumps

Bridge Plugs Operations

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

Rejuvenation Instructions

FLOAT OPERATED LEVEL CONTROLLER

Mooney * Noise Controller Installation, Operation, and Maintenance Manual

INSTRUCTION MANUAL LOW PRESSURE CALIBRATION PUMP MODEL PGL

Transcription:

Tejas Research & Engineering, LLC 9185 Six Pines Drive The Woodlands, Texas 7738 PRESSURE TESTING REPORT Nexgen - 5352 - Plug Testing (Plug #2) Casing Drift: 4.375" 29-Sep-16 Plug OD: 4.25" Tools: T4 Hydraulic Setting Tool (Baker 2) Nexgen Oil Tools X-Factor Frac Plug (Gen 3 rubber seal) 5.5" 26.8# Q-125 Casing Max Pressure 13,3 psi (Max test pressure 1,5 psi) 8:3 - Hold pre-test JSA with customer and begin set up for frac plug testing. 9:45 - Make up plug with supplied WL adaptor kit. Set plug at ambient temperture of 72 F. Measure from top of plug to top of casing. Plug slip ring breaks at 4, psi. Plug shear and set at 42, psi. 1: - Lower test casing and set plug into well to begin test. Having trouble keeping pressure. Trouble shoot for problem. Change out pressure fitting on Tejas' pressure line. 11:8 - Begin pressure test at ambient temperture of 75 F. Bring pressure above casing to 2,5 psi, bring bottom pressure to 5 psi. Continue to regulate pressure above and below plug to achieve an 8,5 psi differential. Achieved 1,2 psi above and 2,3 psi below. Hold pressures losing <4 psi/hour. 13:45 - Start heater. Regulate pressure during heating phase so as not to exceed 1,5 psi max. Reach 2 F at 15:3 hrs holding 1,3 psi above and 1,5 psi below. Begin phase two of test. 16:25 - Per customer request, bleed bottom pressure down to zero psi. Customer wants to hold a 1, psi differential on plug. 16:5 - Customer calls good test after holding 1, psi differential on plug for 3 minutes. 17: - End Test. Begin cooling down and bleeding down pressure from chamber. 18: - Remove casing to inspect plug. Measure from top of plug to top of casing. Plug did not move during pressure test. Customer confirms good test per procedure. Remove plug from casing with Tejas 1 ton hydraulic press.

Tejas Research & Engineering, LLC 9185 Six Pines Drive The Woodlands, Texas 7738 PRESSURE TESTING REPORT Nexgen - 5352 - Plug Testing (Plug #3) Casing Drift: 4.375" 3-Sep-16 Plug OD: 4.25" Tools: T4 Hydraulic Setting Tool (Baker 2) Nexgen Oil Tools X-Factor Frac Plug (Gen 3 rubber seal) 5.5" 26.8# Q-125 Casing Max Pressure 13,3 psi (Max test pressure 1,5 psi) 8: - Hold pre-test JSA with customer and begin set up for frac plug testing. 9:5 - Make up plug with supplied WL adaptor kit. Set plug at ambient temperture of 71 F. Measure from top of plug to top of casing. Plug slip ring breaks at 4, psi. Plug shear and set at 4, psi. 9:45 - Lower test casing and set plug into well to begin test. Begin heating chamber and regulating pressure not to exceed 1,5 psi max pressure. 11:15 - Reached temp of 2 F at 6,25 psi. Experienced extreme pressure drop. Found leak on fitting going to chamber. Pressured back up with communication under plug. Could not regain steady holding pressure. Stop test to inspect casing/plug. Begin cool down and bleed down pressure. 12:3 - Remove casing from test chamber for to inspect plug. Measure from top of plug to top of casing. Plug did not move. Customer confirms measurment my Tejas technician. Inspect casing and found diformity on exterior of casing. Remove plug with Tejas 1 ton hydraulic press. Mic inside of casing. Drift of casing shows inconsistant. Measures 4.376" to 4.55". By Tejas saftey standards, test casing is no longer safe to use and must be discarded or destroyed. Customer confirms findings and ends testing at 14:5 hrs.

X-FACTOR FULLY DISSOLVABLE PLUG BALL DROP BRIDGE PLUG CAGED BALL 35 F (177 C) 35 F (177 C) 35 F (177 C) 1, psi (7) 1, psi (7) 1, psi (7) X-FACTOR FULLY DISSOLVABLE PLUG BALL DROP 5.5 (139.7) BRIDGE PLUG 5.5 (139.7) CAGED BALL 5.5 (139.7) 2-26.8 21-26.8 22-26.8 X TREME COMPOSITE PLUG BALL DROP BRIDGE PLUG CAGED BALL X TREME COMPOSITE PLUG BALL DROP 5.5 (139.7) BRIDGE PLUG CAGED BALL 2-26.8 21-26.8 22-26.8 TEMP F ( C)

Pressure (psi) Temperature ( F) NexGen - 5352 - Plug Testing Tejas R&E - Plug 2 - Set - 9/29/216 4 1 35 PLUG SHEAR @ 42, psi 9 3 8 7 25 6 2 5 15 4 3 1 2 5 Slips Break @ 4, psi 1 9:36:43 9:37:26 9:38:1 9:38:53 9:39:36 9:4:19 9:41:2 9:41:46 9:42:29 9:43:12 9:43:55 9:44:38 Above Pressure (set) Below Pressure Part Temp

Pressure (psi) Temperature ( F) NexGen - 5352 - Plug Testing Tejas R&E - Plug 3 - Set - 9/3/216 4 68 35 Plug set @ 4, psi 66 3 64 25 62 6 2 58 15 56 1 54 5 Slips break @ 4,2 psi 52 5 8:53:31 8:54:14 8:54:58 8:55:41 8:56:24 8:57:7 8:57:5 8:58:34 8:59:17 9:: 9::43 Above Pressure (set) Below Pressure Part Temp