Electronic Control Pump Instruction Manual

Similar documents
Electronic Control Pump Instruction Manual

Electronic Control Pump Instruction Manual

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

BS Series Basket Strainer

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

100C Air Compressor Kit

Accu-Tab Systems 1000 Series by Axiall Corporation

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

200 PSI COMPRESSORS - MODEL NUMBERS

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

Instruction Sheet. SUPERSEDES: New EFFECTIVE: August 1, 2013

IMPORTANT SAFETY INSTRUCTIONS

Installation, Operating, Maintenance and Safety Instructions for. Pressurised water systems for boats

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

Accu-Tab PowerBase 3070AT by Axiall Corporation

Accu-Tab Systems 2000 P Series by Axiall Corporation

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

J Air and Water Kit Instructions Part# 02584

ACCU-MIX 1200 / / 26270

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

400C & 450C DUAL PERFORMANCE VALUE PACKS

TITAN FLOW CONTROL, INC.

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

D Series Air and Water Kit Part# 02550

G7S Hand Pump Owner s Manual

444C DUAL PERFORMANCE VALUE PACK

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

KJ4000 Operating Instructions & Parts Manual NSN

Installation and Operation 370ESP (Electric Single-Point Purger) & 370ESPR (Retrofit Purger)

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

SILENTAIRE TECHNOLOGY

User Instruction Manual

Operator: Save these instructions for future use!

PC1131 Electric Air Compressor

453 Series Steam Heated Vaporizing Regulator

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

Vessel Installation and Operating Manual

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

Marschalk Model # 94000

TITAN FLOW CONTROL, INC.

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

SILENTAIRE TECHNOLOGY

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

Eaton Filtration, LLC

Operating Manual. Model BAC-30RT30/BAC-30DC

IMPORTANT SAFETY INSTRUCTIONS

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

200 PSI FAST-FILL AIR SOURCE KIT

WPB 5 / 7 / 10 INSTALLATION, OPERATION, & MAINTENANCE

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

FLANGED MULTI-PORT BALL VALVES

2 Gallon Air Compressor

OPERATING INSTRUCTIONS

480C DUAL PERFORMANCE VALUE PACK

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Lubricated TC Models

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

200 PSI HIGH-FLOW AIR SOURCE KIT

Yoke Block Instruction Manual

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

NGP-250/500 Nitrogen Generator Quick Start Guide

MODEL NUMBER: P PORTABLE COMPRESSOR

Installation and Maintenance Manual. ECO Filtration Unit with 6-way-Top-Mount-Valve. Art. Nr

Easy Nest Kits. Installation Suggestions

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number

Installation and Operating Manual

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Budget Range Operators Handbook

HAS2400 Hepa Air Scrubber

Code AWC20HP Air Compressor

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

36H SERIES Combination Gas Valve

System Pressure Manager Standard & System Pressure Manager Plus

Operating Instructions Models and Hydrostatic Test Pumps

accidents which arise due to non-observance of these instructions and the safety information herein.

AQUAMATIC EASY NEST KITS INSTALLATION SUGGESTIONS

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Accu-Tab PowerBase 3012AT by Axiall Corporation

HAYWARD FLOW CONTROL TFS SERIES FLOW METER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

MODEL NUMBER: P PORTABLE COMPRESSOR

Transcription:

TQ Series Electronic Control Pump Instruction Manual 234867 ISO 9001 Certified Walrus America Inc

EC Declaration of Conformity Manufacturer: Walrus Pump Co., Ltd. Address: No. 83-14, Dapiantou, Sanjhih Township, Taipei County 252, Taiwan Declare that the machinery described: Name : Water Pump Model : TQ Series Conform to the following directive: 2006/42/EC Machinery directive 2006/95/EC Low voltage directive 2004/108/EC EMC (Electromagnetic compatibility) directive Refer to the following standards: EN ISO 12100-1:2003 EN ISO 12100-2:2003 ISO14121-1:2007 EN335-1:2001 EN 809:1998 EN335-2-41:2001 EN61000-6-2 EN61000-6-3 R&D department manager: Kao Tien-chuan Manager: ~ 1 ~

TQ Series Instruction Manual Please read all instructions carefully before installing your new systems, as failures caused by incorrect installation or operation are not covered by the warranty. I. Product The TQ series are designed for the pumping of non-aggressive water, or water not containing solid particles. II. Operating conditions: 1. Ambient temp. : Max. +104ºF (40ºC) 2. Liquid temp. : +39ºF(4ºC) ~ +104ºF(40ºC)Max. 3. System pressure: Max. 120 PSI 4. Relative humidity: Max. 85%(RH) III. Installation 1.The pump foundation should be rigid enough to absorb any vibration from the motor, and the pump should be securely bolted to the foundation. 2. It is recommended that the plumber/installer provides an adequate draining system to avoid damage in case of leakage, particularly when installed indoors. When it is installed outside, it should be covered by a weather-proof housing, well ventilated to allow motor heat to escape. 3. Connect the suction pipe to the side and discharge pipe on the top. 4. When use with water heaters, a check valve should be installed between pump (discharge) pipeline and water heater (suction) to avoid high-pressure steam backflow. 5. It is required to shut off the pump when the liquid source is unavailable; although it has the dry run cut off function. 6. The pump has a built-in check valve. Please do not install any other valve on the suction. 7. For TQ1500/2200/3700, Please cut out the center of the rubber gasket inside the inlet and outlet flanges as it will block the water flow. 8. When performing regular maintenance, the prime cover has to open in order to check the condition of the check valve. DO NOT apply any bonded material (such as silicon, glue etc) to seal the chamber cover (see drawing below). IV. Piping 1. The suction line should be installed as short and straight as possible, with a minimum of bends. The internal diameter of the suction pipe must be equal to, or greater than the ports of the pump. 2. The connection between the suction line and pump must be airtight, and the suction pipe must be positioned so it has an upward slope to the pump (thus avoiding the formation of air pockets). 3. If it is likely the water supply may contain solid particles such as leaves, sand, a filter should be installed before the pump to avoid blocking of water ways. 4. If hose is used as the suction pipe, it must be non-collapsible. 5. To minimize pressure drop, the discharge pipe should be at least the same size as the discharge port of the pump. 6. For long suction pipes or high suction lifts over 13 ft, the suction pipe should be of greater diameter than the suction port. 7. Ensure all connections are completely sealed using thread tape only. V. Connections to Water Source 1. Flooded Suction from cistern or storage tank No pressure adjustment is required. Recommend to install a bypass valve so water supply can be turned off for pump removal and servicing. 2. Flooded Suction - from city water or pressure tank. There will be an inlet pressure added to the pump and is required to satisfy to following two criteria: ~ 2 ~

a) The inlet pressure added to the pump pressure must not exceed 120 psi. b) The inlet pressure must be 10 psi lower than the max pump pressure. - When the inlet pressure is higher than the preset starting pressure, it requires adjusting the starting pressure. Please READ THE WARNING before adjusting pressure. The max inlet pressure is as follows Model Max inlet pressure TQ200 21 TQ400 30 TQ800 53 TQ1500 48 TQ2200 50 TQ3700 48 Max pump pressure 31 40 67 58 72 WARNING: - The inlet pressure will add to the pump pressure. When the total system pressure exceeds the local code limits for home pressure, it is required to install a pressure reducing valve to reduce the inlet pressure. Too high system pressure will also endanger your pipe systems. - Pressure adjustment WILL NOT change the pump discharge pressure. - When inlet pressure is inconsistent (for example from 20 to 50 psi), recommend to install a pressure reducing valve to avoid total system pressure exceeding the limit. 3. Suction Lift - below ground water sources Whenever the installation position of the pump is higher than 3ft above the lowest water level, a foot valve must be installed on the end of suction pipe. - Please refer to the factory preset starting pressure and max pressure as follows: The factory preset starting pressure Model TQ200 TQ400 TQ800 TQ1500 TQ2200 TQ3700 Power (HP) ¼ ½ 1 2 3 5 Prest pressure (psi) 17 26 36 43 43 43 ~ 3 ~ The TQ maximum pressure. Model Maximum Pressure ( psi ) TQ200 31 TQ400 40 TQ800 67 TQ1500 58 TQ2200 TQ3700 72 VI. Electrical connection This mark located outside the connection box is a warning for an electrical hazard. 1. Ensure the mains voltage is the same as the value shown on the motor plate and that the pump is safely connected to ground/earth. 2. The single phase models are supplied with plug and lead and can be connected directly to the mains supply. The 3 phase models should hook up with a circuit breaker. VII. Wiring diagram WARNING: Risk of Electric Shock - This pump is supplied with a grounding conductor and groundingtype attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle". Before operation, please ensure the voltage is correct and the circuit breaker and grounding connectors are all connected in accordance with local regulations. Single-phase power supply L1 L2 Input power L1 L2 Input power L3 Grounding 3-phase power supply (check if rotation is correct) Fig. 1 Grounding

VIII. Starting 1. Before starting, the pump must be primed. Please follow the procedure as shown in Fig 3. a. Remove the filling plug Water b. Fill water in chamber X. Operation and maintenance Under normal operating conditions, the pump does not require any maintenance as long as the following points are observed: 1. Periodically check the condition of the check value and strainer (if used). 2. If the pump is to be inactive for long periods, it should be rinsed thoroughly with clean water, then, drained and stored in a dry place. It has to be re-primed before start-up. 3. If the pump rotor is seized up after periods of inactivity, please place a screw driver from the motor end to rotate the rotor. It should free the pump rotor. ( See Fig 3 ) If this does not remedy the problem, the unit will need dismantling. Fig. 3 c. Replace the filling plug Fig. 2 2. Installation where the pump inlet is below the water supply, remove the priming plug and allow the water to flow into the priming chamber until all air is expelled. 3. The priming procedure should be repeated until all air is expelled and the pump delivers a full stream of water without air bubbles. 4. The pump must always be checked for prime if not used for a prolonged period. It is imperative to fill the pump with liquid before operation as dry running causes irreparable damage to the mechanical seal. 5. When 3-phase motor is supplied, please ensure if the rotation is correct. You can switch any of the 2 wires to get your desired rotation. IX. Precautions 1. The pump should be shut down and the trouble corrected if the pump is running at speed and found to have any of the following problems: - No liquid discharged - Not enough liquid discharged - Excessive vibration - Motor runs hot 2. Do not allow the pump to continually start and stop (cycling) as this will reduce the motor life. 3. Cycling can occur on pressure units when the pressure tank pre-charge drops, or where there is a leak in the discharge plumbing. ~ 4 ~ 4. Pressure tank air charge should be checked at regular intervals of every 3 months and after the pump has not been used for a prolonged period.to check the Pressure Tank air pressure, turn off power, open a tap on the discharge line to release pressure from the pump, unscrew the black plastic cover and apply an accurate pressure gauge to the valve as shown in Fig 4. Pressure should be adjusted to the original pre-charge as follows: TQ200: 17 psi (1.2 Kg/cm²) TQ400: 26 psi (1.8 Kg/cm²) TQ800: 36 psi (2.5 Kg/cm²) TQ1500 up to TQ3700: 36 psi (2.5 Kg/cm²) Fig. 4

Flooded Suction Performance Table TQ200 Inlet pressure Flow rate (psi) 3 gpm 6 gpm 9 gpm 12 gpm 15 gpm 5 32 27 22 17 10 10 37 32 27 22 15 15 42 37 32 27 20 ** 20 47 42 37 32 25 ** Need to adjust pressure switch setting when inlet pressure is higher than the preset activation point (TQ200 preset at 17 psi) TQ400 Inlet pressure Flow rate (psi) 3 gpm 6 gpm 9 gpm 12 gpm 15 gpm 18 gpm 10 48 42 37 30 23 15 20 58 52 47 40 33 25 ** 30 68 62 57 50 43 35 ** Need to adjust pressure switch setting when inlet pressure is higher than the preset activation point (TQ400 preset at 26 psi) TQ800 Inlet pressure Flow rate (psi) 3 gpm 6 gpm 9 gpm 12 gpm 15 gpm 18 gpm 21 gpm 10 71 65 50 43 35 23 20 81 75 70 53 45 35 30 91 85 80 70 63 55 45 ** 40 101 95 90 80 73 65 55 ** Need to adjust pressure switch setting when inlet pressure is higher than the preset activation point (TQ800 preset at 36 psi) TQ1500 Inlet pressure Flow rate (psi) 10 gpm 20 gpm 30 gpm 40 gpm 50 gpm gpm 10 63 59 55 48 39 27 20 73 69 65 58 49 37 30 83 79 75 68 59 47 40 93 89 85 78 69 57 TQ2200 Inlet pressure Flow rate (psi) 10 gpm 20 gpm 30 gpm 40 gpm 50 gpm gpm 10 66 62 58 53 46 36 20 76 72 68 63 56 46 30 86 82 78 73 66 56 40 96 92 88 83 76 66 TQ3700 Inlet pressure Flow rate (psi) 10 gpm 20 gpm 30 gpm 40 gpm 50 gpm gpm 10 80 75 70 65 59 49 20 90 85 80 75 69 59 30 100 95 90 85 79 69 40 110 105 100 95 89 79 ~ 5 ~

XI. Adjust pressure switch Adjust the pressure switch setting (according to the pump models) as shown in Fig 5. Make sure the system is primed. The pump is supplied with a preset pressure in the pressure switch. For most applications, it will be satisfactory. In some cases a different pressure may be required. This can be achieved by following the instructions below. However, it is highly recommended that the adjustment is only done by the professional personnel. Instructions for pressure adjustment (Fig. 5): 1. Adjust clockwise ("+") to increase the pump activation pressure. 2. Adjust counterclockwise ("-" ) to reduce the pump activation pressure. 3. Do Not need adjustment when incoming water is gravity feed or no pressure. 4. Adjust the activation pressure to be higher than the incoming pressure from city main. However, please notice the inlet pressure will add to pump max pressure as total system pressure. When it makes system pressure too high, please install pressure reducing valve on the inlet pipeline 5. After adjustment is made, turn it on and off several times to make sure it operates normally. TQ 200/400/800 Open the cover to adjust the pressure - + ~ 6 ~

TQ 1500/2200/3700 Open the cover to adjust the pressure - + Fig. 5 XII. Adjust flow switch Following the adjustment of the pressure switch, and with the unit running, close all taps on the discharge. If the pump cuts out, no adjustment is necessary. If the pump does not cut off, please refer to Fig 6: 1. For TQ200/400/800: Loose the hex. screw and use a screw driver to adjust the flow switch clockwise (+) until the pump stops. 2. For TQ1500/2200/3700: Open the control box and move the flow level control to a higher position (to allow more flow) until the pump stops. Open and close a tap on the discharge several times to ensure that the pump starts and stops normally. No further adjustments are necessary. TQ 200/400/800 TQ 1500/2200/3700 ~ 7 ~ Fig. 6

Warning The pump is not designed for continuous operation under low discharge flows such as slow closing float valves, slow running taps. Under this application, please install an extra tank of adequate volume to avoid cycling. (Fig7) Extra Pressure Tank pipe tee Fig. 7 Please set the extra pressure tank prussure the same as activation pressure. Leaking discharge line and leaking taps will damage the unit through causing the pump to repeatedly start and stop. XIII. Frequently asked questions: 1. What causes the TQ to start? The TQ has the built-in pressure switch and internal flow switch. Each of these can turn the pump on depending on water consumption. The pump will start when: - The pressure is BELOW the pressure switch activation point. OR - The flow rate is greater than 0.7 GPM. The preset activation point for each model is provided in the pump specifications. The cut in pressure must be lower than the preset activation pump; otherwise the pump will not start. 2. What causes the TQ to stop? The flow switch is designed to automatically stop the TQ pump when flow drops to below 0.7 GPM. The pump will shut off in a few seconds after flow stops (TQ200-800 is programmed to stop after 8 seconds and TQ1500-3700 is programmed to stop after 15 seconds). In addition, the TQ will be turned off in the event of dry-run or over temperature alarm. 3. What is the purpose of the built-in pressure tank? The pressure tank comes from the factory pressurized at approximately 17-36 psi (with the pump pressure at zero). It is designed to minimize motor startup due to small flow demand or minor leak of the pipeline. TQ200-17 psi (1.2 Kg/cm²) TQ400-26 psi (1.8 Kg/cm²) TQ800-36 psi (2.5 Kg/cm²) TQ1500 up to 3700-36 psi(2.5 Kg/cm²) 4. How is the dry-run condition determined and the protection provided? The dry-run is defined when the motor is running AND the flow rate is less than 0.3 GPM AND when pressure is less than the pressure switch setting. The protection is provided: When the pump is run dry 2 minutes, it will automatically shut off for 10 minutes and then attempts to restart. When all 3 attempts are failed, the pump will rest for 1 hour and then attempts to restart. This protection mode will be repeated until the water supply is back to normal. In case the pump is cycling (on-and-off repeatedly) due to small flow (less than 0.3GPM), air pocket in the system, air loss in the pressure tank or leak in the pipeline, the protection is provided: The pump will run for 8 seconds and stop for about 3 seconds. When the cycling mode repeat for 15 times consecutively, the pump will be rest for 1 hour. Then it will start over the protection mode until the problem is corrected. Note: Above unusual pump shutdown, users may remove power plug over than 6 seconds and reconnect again to restart, if it is necessary. ~ 8 ~

XIV. Dimensions: (in.) TQ200/400/800 C 3.9 1.77 Outlet NPT 1" Inlet NPT 1" 8.82 5.71 3.3 6.89 A B 5.12 6.3 4-Ø0.4 TQ1500/2200/3700 C Inlet TQ1500 : NPT 1½" TQ2200 : NPT 2" TQ3700 : 10.63 5.83 2.56 Outlet TQ1500 : NPT 1½" TQ2200 : NPT 2" TQ3700 : 14.76 9.06 5.51 8.27 B A 6.69 8.66 Model TQ 200 TQ 400 TQ 800 TQ1500~3700 A (in.) 14.37 14.92 17.76 19.72 B (in.) 6.26 6.77 7.80 7.76 C (in.) 6.46 6.97 7.99 8.35 XV. Specification: Model Power ( HP ) Cycle ( Hz ) Phase ( Ø ) Voltage ( V ) Amp's ( A ) Inlet (NPT) Outlet (NPT) H max. ( ft ) Q max. ( GPM ) TQ200 ¼ 1 115 or 230 4.0 or 2.0 1" 1" 72 16.9 TQ400 ½ 1 115 or 230 6.0 or 3.0 1" 1" 92 18.5 TQ800 1 1 115 or 230 11.0 or 5.5 1" 1" 154 23.8 TQ1500 2 1 or 3 230 9.5 or 6.5 1½" 1½" 134 66.0 TQ2200 3 3 230 9.5 2" 2" 138 71.3 TQ3700 5 3 230 12 2" 2" 167 71.3 ~ 9 ~

XVI. Troubleshooting Before starting work on the pump, make sure that the electricity supply has been switched off and that it cannot be accidentally switched on. Problem 1. pump does not start Cause a. No power supply b. Too low/high voltage Remedy Connect the electricity supply Check if soupply voltage is within ± 10% 2. Pump cuts out during operation c. Inadequate pressure at suction or discharge d. Seized-up pump a. Seized-up pump b. Overloaded motor c. Poor water supply d. The protection for pump dry run or cycling is activated. Follow V and XI of the Operation Manual Place a screwdriver against the shaft end of the motor to check it the rotor will spin freely, and contact your pump supplier. Same as above Turn off the power supply and restart or contact your pump supplier. Check if pump suction inlet is blocked. Check the detailed information per XIII (Frequently asked questions). Item 5 3. Pump starts when no water is consumed 4. Pump starts and stops too frequently 5. Electric shock 6. Pump does not stop when water is not consumed 7. Pump runs normal but with very low discharge flow a. Existing pipe is leaking b. Air tank pressure is too low c. Pipe suck in air. a. Leakage in suction pipe or air in the water. b.discharge flow is too low. a.ineffective grounding a. Poor water supply or air suck in. b. Pressure set is too high c. Flow set is too small. d. Defective check valve. a. 3-phase motor runs in wrong rotation. b. Poor water supply Fix the leakage. Charge air per X-4 of the manual. Check the suction pipe and water supply. Check the suction pipe and water supply. Set your tap on a higher water flow. Reactivate grounding. 1. Turn off the power supply and open the refilling plug to release the air. Then restart. 2. In case of long suction pipes, turn off the power and make sure if water supply is adequate. Adjust pressure per XI Adjust flow switch per XII Clean or replace with a new valve. Switch any of the 2 wires from motor terminal to correct rotation. check if water supply is adequate and if the suction pipe is blocked. ~ 10 ~

Limited Warranty G2 Products manufactured by Walrus Pumps Co (Walrus) are warranted to the first user only to be free of defects in material and workmanship for a period of 12 months from date of installation, but no more than 24 months from date of shipment. Walrus' liability under this warranty shall be limited to repairing or replacing at our election, without charge, FOB Walrus' distribution center or authorized service agent. Walrus will not be liable for any cost of removal, installation, transportation or any other charges that may arise in connection with warranty claim. The warranty period commences on the date of original purchase of the equipment. Proof of purchase and installation date, failure date, and supporting installation data must be provided when claiming repairs under warranty. This warranty is subject to due compliance by the original purchaser with all directions and conditions set out in the installation and operating instructions. Failure to comply with these instructions, damage or breakdown caused by fair wear and tear, negligence, misuse, incorrect installation, inappropriate chemicals or additives in the water, inadequate protection against freezing, rain or other adverse weather conditions, corrosive or abrasive water, lightning or high voltage spikes or through unauthorized persons attempting repairs are not covered under warranty. Walrus will not be liable for any incidental or consequential damages, losses, or expenses, arising from installation, use, or any other causes. There are no express or implied warranties, including merchantability or fitness for a particular purpose, which extend beyond those warranties described or referred to above. Certain states do not permit the exclusion or limitation of incidental or consequential damages or the placing of limitations on the duration of an implied warranty, therefore, the limitations or exclusions herein may not apply. This warranty sets forth specific legal rights and obligations, however, additional rights may exist, which may vary from state to state. Supersedes all previous publications 9808 Whithorn Drive, Houston, TX 77095 Web: www.walrusamerica.com Walrus America Inc P099C019U200-03