Aneta Hałka- Grysińska, Ewelina Sitarczyk, Wojciech Markowski, Tadeusz H. Dzido, Anna Klimek- Turek, Adam Chomicki Medical University of Lublin,

Similar documents
Gradients in ion chromatography. Optimal separation with shorter analysis time

MV5: Automated concentration system

AKTA pure 25 New Owner s Intro

Agilent Dimension Software for ELSD User Manual

Manual. Online Degasser DDG-75. Manual Degasser DDG-75 April DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE Hockenheim Germany

Evaluation of linear and step gradient performance and retention time precision of the Agilent 1200 Series Rapid Resolution LC

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

GUIDE TO ULTRA-FAST HPLC. Quick Tips for Converting Conventional Reversed-Phase HPLC Separations to Ultra-Fast Separations

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Equipment and Accessories. ROMIL LiQuiSure. Designed for High Purity Containment & Dispensing PURE CHEMISTRY

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Investigation of Thermal Effects of CO 2 on Earth-Atmosphere System

The instrument will process the samples one by one till all the samples have been cleaned up.

APPLICATION NOTE. GC Integrated Permeation Device

Application Note. Rapid performance verification of AZURA systems with refractive index detector. Summary. Introduction

Quantitative Analysis of Hydrocarbons by Gas Chromatography

SOP: Buck Scientific BLC-20P HPLC Operation

Customer Responsibilities

During today's webinar we're going to look at the following topics:

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

FAST EVAPORATION AT NORMAL PRESSURE

FRANZ CELL TEST OF NANO GLUTATHIONE WITH HPLC ANALYSIS

Acclaim RSLC. (Rapid Separation Liquid Chromatography)

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

LC, RSLC, Bio RS and Dual Gradient Systems

Air Quality 2b - PFGC/FID Analysis of Benzene and Toluene in Automobile Emissions

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

Series 2G Diaphragm Actuators

Rev. CO Packed Columns for Normal Phase Chromatography. TSKgel NH m INSTRUCTION MANUAL

Experimental Verification of Integrated Pressure Suppression Systems in Fusion Reactors at In-Vessel Loss-of -Coolant Events

Setting a New Standard in Flash Chromatography Performance

1 SE/P-02. Experimental and Analytical Studies on Thermal-Hydraulic Performance of a Vacuum Vessel Pressure Suppression System in ITER

MB-SP Series Solvent Purification System

Supporting Information for Micro-Collection of. Gases in a Capillary Tube: Preservation of Spatial

Customer Responsibilities. Important Customer Information. Agilent 6400 Series Triple Quad LC/MS Site Preparation Checklist

Joint industry project on foam

Indian Institute of Technology Kanpur Environmental Engineering and Management Department of Civil Engineering

A NOVEL RP-HPLC METHOD FOR THE QUANTIFICATION OF ICATIBANT IN FORMULATIONS

OLED vacuum deposition cluster system Sunicel Plus 400 / Plus 400L (Sunic Systems)

Applications of a Magnetic Sector Process Mass Spectrometer to the Analysis of Variable Vacuum Samples

Generating Calibration Gas Standards

University of Minnesota Nano Center Standard Operating Procedure

Customer Responsibilities

Peak Biotech - Company & Product Presentation

The Gas Attenuator of FLASH

Applied Technology and Best Practices in CEE. Conference

OMCL Network of the Council of Europe QUALITY ASSURANCE DOCUMENT

UltiMate 3000 Viper Capillary Kits for Intelligent LC (LCi) System Solutions

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

Integration of amino acid, acylcarnitine and steroids analysis in single FIA/LC-MS/MS platform

Ensuring Best Possible UHPLC Performance Through an Innovative Capillary and Fitting Design

Digital Vacuum Regulator

CHEMICAL ENGINEERING SENIOR LABORATORY CHEG Initiated Chemical Vapor Deposition

LEVANT WORMSEED FOR HOMOEOPATHIC PREPARATIONS CINA FOR HOMOEOPATHIC PREPARATIONS

(2 pts) Draw the line of best fit through the data and estimate the concentration of Fe in your sample solution.

Gas Sampling Fitting with MK2.1 and L-Probe

Under pressure pushing down

The Discussion of this exercise covers the following points: Pumps Basic operation of a liquid pump Types of liquid pumps The centrifugal pump.

Trion PECVD SOP IMPORTANT: NO PLASTIC, TAPE, RESISTS, OR THERMAL PASTE ARE ALLOWED IN THE CHAMBER

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:

Trace-Level Analysis of Metanephrines in Plasma by HILIC LC-MS/MS

Improvements in the Reliability, Costs and Processing of WLP/RDL Circuits

Chapter 3 EXPERIMENTAL: EQUIPMENT, SET-UP, AND PROCEDURE

Simultaneous Determination of a Panel of 22 Steroids in Urine and Serum by SPE and LC-MS/MS

Usage Policies Notebook for Parylene Coating System

Gas Diluter Portable Gas Dilution System User s Manual

Practical approach and problems in in-situ RGA calibration

User guide for operating the Agilent 6420A QqQ mass spectrometer by direct infusion/injection

Video Notes. LC Troubleshooting Series Retention Time Shifts

TROUBLESHOOTING. Dwell Volume Revisited. Gradient transfer does not have to be problematic.

Customer Responsibilities

ENSURING AN ACCURATE RESULT IN AN ANALYTICAL INSTRUMENTATION SYSTEM PART 1: UNDERSTANDING AND MEASURING TIME DELAY

H o w t o U s e a R e g u l a t o r t o R e d u c e T i m e D e l a y i n a n A n a l y t i c a l S y s t e m

SHIMADZU LC-10/20 PUMP

understanding of cell size and shape absorption of food substances in villi rate of diffusion gas exchange in air sacs

R-410A 50% R-32 50% R-125.

Determination of Capillary pressure & relative permeability curves

Exhibit 4. Determination of Static Pressure Performance of the Healy Clean Air Separator (Executive Orders VR-201-N and VR-202-N)

CHM Gas Chromatography: Our Instrument Charles Taylor (r10)

VACUUM CHAMBER MANUAL

The SPI Sputter Coater Handbook

Cryogenics of SRF Spoke Cavity Development at SMTF

Three Columns Gas Chromatograph Analysis Using Correlation between Component's Molecular Weight and Its Response Factor

Simplified Backflush Using Agilent 6890 GC Post Run Command Application Note

Customer Responsibilities

REPRODUCIBILITY IN OPTICAL THIN FILM PROCESSING PART 1, THE VACUUM AND PUMPING

ANALYTICAL SCALE HPLC AGILENT SYSTEMS OPERATIONAL QUALIFICATION

Customer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist

International Journal of Research in Pharmaceutical and Nano Sciences Journal homepage:

Automated Determination of Dissolved Gases in Water Anne Jurek

SOP: Derivatized testosterone_01 Revision: 01 Date Effective: 05/17/15

Dionex IonPac AS19-4µm

Autosampler problems!

Organic Elemental Analysis Series II CHNS/O Elemental Analyzer. proven performance. reliable results

AKTA ION EXCHANGE CHROMATOGRAPHY SOP Date: 2/02/05 Author: A DeGiovanni Edited by: C. Huang Reviewed by:

Numerical Investigation of Air Bubbles Evolution and Coalescence from Submerged Orifices Based on OpenFOAM

OPERATION MANUAL NTF-15

OPERATION MANUAL NTF-60 Plus

Title: Xactix XeF2 Etcher Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 03/23/2016

Transcription:

Aneta Hałka- Grysińska, Ewelina Sitarczyk, Wojciech Markowski, Tadeusz H. Dzido, Anna Klimek- Turek, Adam Chomicki Medical University of Lublin, Poland

Outline TheoreLcal basis The current state of technique in analylcal laboratories ObjecLve of the research Results and disscussion Conclusions

IsocraLc and Gradient EluLon Isocra'c the condilons of separalon are not changed throughout the Lme required for the sample separalon Gradient a chromatographic technique using within the separalon area locally different separalon condilons Niederwieser When? - simple separalons When? - general elulon problem

Types of Gradient conlnuous stepwise Mobile- phase gradients ComposiLon ph Ionic strength StaLonary- phase gradients ComposiLon ImpregnaLon AcLvity Gradients concerned with change of Temperature Flow rate Vapor pressure concave linear convex

The Current State of Technique in AnalyLcal Laboratories AMD 2 mullple development of the chromatographic plate in the same direclon each successive run extends over a longer distance between runs, the eluent is completely removed from the chamber and the layer is dried under vacuum each successive run uses a solvent of lower elulon strength focusing effect and gradient elulon results in extremely narrow bands [1] www.camag.com

AMD 2 Advantages Disadvantages good performance good reproducibility separalon can be carried out under a nitrogen atmosphere a long Lme of development stability teslng of samples should be pefrormed (decomposilon of the analyzed components is possible) limited number of suitable solvents lack of adequate and simple model method development and oplmizalon normal- phase systems only can work without operator supervision [1] www.camag.com

Other Eqipment for Mobile Phase Gradient Rybicka Wieland and Determan Luza`o and Okoye Strickland Niederwieser and coworkers Sander and Feld Soczewiński and Matysik Burger and Jaenchen Vajda et al. Markowski, Wróblewski and Dzido

Objec&ve of the Work Developing a device which: enables to perform gradient elulon with one void volume of the mobile phase enables to perform gradient elulon in normal and reverse- phase thin layer chromatography can be easily automated

Horizontal Developing Chamber for Stepwise Gradient EluLon [2] Markowski W., Wróblewski K., Dzido T.H., J. Planar Chromatogr. 25 (2012) 3, 200 207

Isocra&c Elu&on of the Mixture of Ten Dyes % of Methanol (v/v) The chromatograms of the mixture of ten test dyes, RP- 18 W HPTLC plate from Merck, eluent: methanol + water, chromatograms developed in DS- M Chamber (Chromdes) [2] Markowski W., Wróblewski K., Dzido T.H., J. Planar Chromatogr. 25 (2012) 3, 200 207

Gradient Elu&on of the Mixture of Ten Dyes with Horizontal Developing Chamber linear convex concave The chromatograms of test dye mixture, RP- 18 W HPTLC plates from Merck, eluent: gradient of methanol + water ; the development distances are 8 cm [2] Markowski W., Wróblewski K., Dzido T.H., J. Planar Chromatogr. 25 (2012) 3, 200 207

Horizontal Developing Chamber for Stepwise Gradient Elu&on Advantages reasonable 'me of gradient chromatogram development (eg 20-30 min. for 4 6 cm) gradient elulon in reversed- phase systems (bioanalysis) good agreement of the calculated and experimental values of retenlon of separated solutes salsfactory repeatability Disadvantages a lot of manual operalons and operator supervision required margins produclon of 4 mm width of silicone sealant on the whole periphery of the plates is necessary

The New Semi- Automa&c Horizontal Developing Chamber for Stepwise Gradient Elu&on 1. Gas reservoir 2. Reductor valve 3. Three way switching valve 4-9. Eluent fraclons 10. 8- port switching valve 11. Chromatographic plate 12. Horizontal DS chamber 11 12

Picture of the New Semi- AutomaLc Horizontal Developing Chamber for Stepwise Gradient EluLon With pneuma'c delivery solvent system With gradient pump (HPLC)

IsocraLc EluLon of the Mixture of Ten Dyes 20 35 50 65 80 100 % of Methanol (v/v) The chromatograms of the mixture of ten test dyes, RP- 18 W HPTLC plate from Merck, eluent: methanol in buffer ph 3.0, chromatogram developed in Horizontal DS, 5 x 10, Chamber (Chromdes)

Gradient EluLon of the Mixture of Ten Dyes with the New Semi- AutomaLc Horizontal Developing Chamber convex linear concave The chromatograms of the mixture of ten test dyes, RP- 18 W HPTLC plate from Merck, eluent: 4 step gradient of methanol in buffer ph 3.0, development distance 8 cm

Reproducibility of Results Obtained with the New Semi- AutomaLc Horizontal Developing Chamber Substance Migra'on distance Standard devia'on RSD [%] 1 1.65 0.25 15.25 2 6.07 0.60 9.94 3 12.43 0.38 3.04 4 16.43 0.41 2.50 5 18.70 0.59 3.18 6 24.83 0,99 3.98 7 29,23 0,61 2.08 8 35.53 2.01 3.99 9 38.93 2.24 5.76 10 46.03 4.57 9.94 The chromatograms of the mixture of ten test dyes, RP- 18 W HPTLC plate from Merck, eluent: linear gradient of methanol in buffer ph 3.0, development distance 8 cm

The PredicLon of RetenLon by a Computer Program 1,00 Titre du graphique 0,90 0,80 0,70 0,60 0,50 0,40 0,30 0,20 0,10 0,00 Experimental Calculated

The New Semi- Automa&c Horizontal Developing Chamber Advantages limitalon of manual operalons no need for margins produclon resonable Lme of chromatogram development Disadvantages reproducibility is not salsfactory too high difference in migralon distance of solute zones

Conclusions the procedures for the preparalon of chromatographic plates and the process of development of chromatograms were significantly simplified eqipment could be easly automated the reproducibility is slll not salsfactory and requires modificalons of this new equipment

Thank you for your kind aken&on