Multi-Probe Sampling System User Guide & Manual

Similar documents
Geotech 1.66 Reclaimer

Geotech 1.66 Auto-Reclaimer Installation and Operation

Geotech 1.66 Auto-Reclaimer

Geotech 3.5 Reclaimer Installation and Operation Manual

Marschalk Model # 94000

Geotech 1.66 Reclaimer Installation and Operation Manual

Geotech Portable Bladder Pumps Installation and Operation Manual

Geotech Bladder Pumps Installation and Operation Manuals

Geotech 3.5 Auto-Reclaimer

ETL Water Level Meter

A C Sipper. Installation and Operation Manual. Rev Part #

Geotech Bladder Pumps

Pure Water Power Purification System 4-Stage RODI Operations Manual

Geotech Portable Bladder Pumps

CSA Sample Draw Aspirator Adapter Operator s Manual

ET Water Level Meter. Installation and Operation Manual. Rev 8/31/12 Part #

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

Speed control assembly model A-1

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

Paintball Marker. User s Manual. 530 South Springbrook Road Newberg, OR 97132

LUDLUM MODEL 239-1F FLOOR MONITOR. Revised December 2010

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER CONSTANT PRESSURE CYLINDER

Model ASSEMBLY and OPERATING INSTRUCTIONS

Stainless Steel 142 mm Filter Holder YY

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

Installation, Operation, and Maintenance Manual

RK-IR Sample Draw Aspirator Adapter Operator s Manual

3" UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC.

602 STRINGING MACHINE OWNER'S MANUAL

1020 Industrial Drive, Orlinda, TN fax

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Installation and Operating Manual

Pressure Injection Cell Operator s Manual

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

WARNING. Paintball Pistol. Paintball Pistol

TECHNICAL INSTRUCTIONS

Installation Troubleshooting Maintenance Instructions Installation / Start-up

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

4-in-1 Professional Inflator Kit

Booster Pump PB4-60 Replacement Kits

Vessel Installation and Operating Manual

Yoke Block Instruction Manual

Operation Manual. Carbon Filtration Industrial Drive, Orlinda, TN fax

AIR INLINE METAL SHEAR

Paintball Marker. User s Manual. Direct Feed. SC: Stock Class. VSC: Vertical Air Stock Class. 530 South Springbrook Road Newberg, OR 97132

Hydraulic Punch Drivers

HPB25 Hydraulic Paving Breaker

GALISO SOAP OPTION FOR PCT-ADW-D

600 / 600FC OWNER'S MANUAL

TABLE OF CONTENTS. AIR SOURCE : CO2/HPA ONLY (not included)

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

FLUSHMATE III FLUSHMATE FLUSHOMETER - TANK SYSTEM. Owner s Service Manual. 503 Series. 503 Series

MANUAL: Jumbo Siamese and Jumbo Wye

3M Liqui-Cel EXF-10x28 Series Membrane Contactor

2 Sentry MCL Installation, Operation & Maintenance

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

Please Do Not Return This Product To The Store!

Model No Product Name Handpiece Only Complete System

Halsey Taylor Owners Manual

Operators Manual. Supera Floor Stand Anesthesia Machine M1000. Models: M1000 Basic Non-rebreathing M1200 Basic M1200

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

Installation, Operation, and Maintenance Manual

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

FloWash. Industrial Filter Cart

Supplementary Operation, Assembly, Maintenance Manual for F3-42 model and optional attachments

Pressure Dump Valve Service Kit for Series 3000 Units

Sample Pro Portable MicroPurge Pump. User's Guide P/N REV The World Leader in Air Powered Pumps

AR4 4 Auto-Reclaimer. Installation and Operation Manual. Rev 10/9/2017 Part #

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

Anderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions

ULTRA HIGH PRESSURE PAINT GRATE CLEANER FCT-JS OPERATION AND MAINTENANCE MANUAL

BP Controller 300 PSI

FLUSHMATE FLUSHOMETER - TANK SYSTEM. 501-A Series. Owner s Service Manual. 501-A Series

Yoke Block Instruction Manual

ATD /8 x 50 Retractable Air Hose Reel Owner s Manual

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Solid Indicator (Non-mixer) Model CP-30SI

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

ATEX ATEX

GILMONT ACCUCAL FLOWMETERS

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER INLOOP ACE CRUDE OIL SAMPLER

Work Smarter...Not Harder!

DuraSite 3000 Sample Vessel User's Guide. Version Rev-1

RADROVER REAR RACK INSTALLATION MANUAL

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

Pressure Relief Valve Instruction Manual

INSTRUCTION MANUAL GAS TRAK

FLANGED TWO-PIECE BALL VALVES

MANUAL: IN-LINE PIVOT GAUGE IN-LINE GAUGE

TECHNICAL DATA. Page 1 of 12

Atmospheric relief valve type 1100 Installation and maintenance instructions

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

Transcription:

Multi-Probe Sampling System User Guide & Manual Rev. 06/05/12 Part #22200012

Table of Contents CHAPTER 1: SYSTEM DESCRIPTION... 2 FUNCTION AND THEORY... 3 SYSTEM COMPONENTS... 4 CHAPTER 2: SYSTEM INSTALLATION... 6 CHAPTER 3: SYSTEM OPERATION... 8 CHAPTER 4: SYSTEM MAINTENANCE... 9 CHAPTER 5: SYSTEM TROUBLESHOOTING... 10 CHAPTER 6: SYSTEM SPECIFICATIONS... 11 CHAPTER 7: SYSTEM SCHEMATIC... 12 CHAPTER 8: REPLACEMENT PARTS LIST... 13 THE WARRANTY... 16 EQUIPMENT RETURN POLICY... 16 EQUIPMENT DECONTAMINATION... 16 1

DOCUMENTATION CONVENTIONS This uses the following conventions to present information: WARNING An exclamation point icon indicates a WARNING of a situation or condition that could lead to personal injury or death. You should not proceed until you read and thoroughly understand the WARNING message. CAUTION A raised hand icon indicates CAUTION information that relates to a situation or condition that could lead to equipment malfunction or damage. You should not proceed until you read and thoroughly understand the CAUTION message. NOTE A note icon indicates NOTE information. Notes provide additional or supplementary information about an activity or concept. 2

Chapter 1: System Description Function and Theory The Multi-Probe Sampling System Flow Cell is designed for use in either high volume (1-3 gpm.) or low volume, (100ml to 1 gpm.) applications. Geotech s flow cell systems are capable of supporting up to five probes simultaneously from a variety of meter and probe combinations. The system includes grommets of varying sizes to accommodate many of the most common sensor probe diameters. Geotech multi-parameter meters are strongly recommended for use with these systems and are available as a complete flow cell and meter kit. Water from the sample or discharge stream of a pumping device is introduced through the bottom of the flow cell chamber. Geotech s engineered flow pattern is designed in such a manner that water flows in a circular pattern across the analytical probes and discharges through the top of the chamber. The design of the Geotech Multi-Probe Sampling System is such that no manual stirring of the probes or sample is necessary. Additionally, there is minimal contact of the probes with air, thus assuring maximum contact of the sample with the probes for accurate and reliable readings. Geotech Multi-Probe Sampling System Flow cells also feature a blow-out plug to assure the system is not over pressurized. With Geotech s optional three way valve assembly (sold separately), you can moderate the discharge stream from your pump to properly use your Flow Cell up to its capacity. When its time to collect your analytical sample, the discharge stream can be disconnected from the three way valve, and into your collection container. 3

System Components Hose Barb Fitting Probe Port Stainless Steel Clamp Chamber Body Top Chamber Body Bottom Retaining Pin for legs Blow Out Port Drain Plug Hose Barb Fitting Aluminum Leg Rubber Foot 4

The probe chamber accepts up to five probes simultaneously. Four of the ports accommodate probes from ⅛ to ⅝ in diameter. The fifth port can accommodate from ¾ to 1. Any or all ports can be plugged off with a PTFE blank when not in use. Each port contains: 1 Silicone grommet 1 Aluminum washer (sized to fit) 1 PTFE blank seal 1 Aluminum threaded cap Each multi-probe monitoring chamber comes with five different sizes of probe grommets and associated parts: 2.375 to.500 probe gripping range 2.500 to.625 probe gripping range 1.750 to.875 probe gripping range 1 ⅜ Hosebarb inlet 1 ½ Hosebarb outlet 5 ft ½ x ⅝ vinyl tubing Three additional probe grommets & washers are also sent with complete multi-probe monitoring chamber kits. 1.125 to.250 probe gripping range 1.250 to.375 probe gripping range 1.875 to 1.00 probe gripping range 1 blow out plug 1 ¼ Hosebarb for inlet 1 ½ Hosebarb for inlet 1 gasket for unit 1 O-ring for legs 5

Chapter 2: System Installation The Multi-Probe Sampling System is shipped out, either in the Flow Cell carrying case, or in a shipping box, with the chamber body fully assembled and the ports blocked with the PTFE blank seals. To use the Multi-Probe Sampling System, the legs must be properly attached and the meter probes must be calibrated and inserted into the probe ports. Leg Attachment Low Volume Model The legs of the low volume model will thread directly into the flow cell chamber bottom. Be careful to avoid over-tightening or cross threading. Carefully align the threads of the aluminum leg with the threaded brass inserts in the bottom of the flow cell. If necessary, use a counterclockwise motion until the leg stops. Some threads may still be showing on the outside of the chamber body. If the leg is firmly in place, then the leg is properly attached. When installing legs on the Low Volume Model be careful to avoid over-tightening and cross threading. High Volume Model For a High Volume Flow Cell, insert leg into chamber body bottom, aligning roll pins on leg with notches (the O-rings should already be in place, helping to secure the fit). Insert the retaining pin through the holes in the leg ports on the flow cell chamber bottom and the hole through the flow cell leg. Inserting Probes The probes should be inserted into the chamber once it is fully assembled. This will protect the probe tips from accidental damage. If the chamber is ever disassembled with probes installed in the ports, the top should be carefully laid on its side. 6

To insert the probes into ports the PTFE blanks must be removed and the appropriate sized grommet must be in place. If the Multi-Probe Sampling Chamber was purchased with a complete set of WTW field meters, the appropriate sized grommets will already be in place. The user will want to be sure the grommet that best grips the probe is being used (see System Components section). Unthread the aluminum cap for the port desired and remove the PTFE blank seal. Set this carefully aside in the kit provided to avoid accidental loss. If it is necessary to select a different grommet; replacement should be made at this point. With the correct grommet in the port, place the metal washer on top of the grommet and replace the aluminum cap, threading gently into place. Do not tighten. For best results, slide the probe into the port through the silicone grommet gently until the probe tip is just at or above the top of the clamp that holds together the top and bottom of the chamber body. It is important that the tip of the probe be inserted below the bottom of the port, yet be at least ½ away from the bottom of the chamber. Do not jam, or use so much force inserting probes that they impact the chamber bottom or cause damage to the probes. When the probe is properly inserted, tighten the aluminum cap being careful not to over-tighten. Over-tightening could damage the probe or crack the Flow Cell ports. 7

Chapter 3: System Operation Once all of the probes have been calibrated and are in place, monitoring can begin. This unit is designed to be used directly in-line from a ground water sampling pump or any other water source that is pumped or can flow up through the chamber. Water is pumped through the bottom of the monitoring chamber. As it fills, water circulates around the probe, and exits through the top of the chamber. As the water flows through the chamber, use the analytical instruments to monitor readings and chart or data-log the results. This is not a pressure chamber. System limitations are a maximum 8 psi differential pressure or the pressure blow out plug will blow out. Removing Probes When removing the probes, turn the aluminum cap counterclockwise until very loose. Firmly grasp the probe where it enters the port and pull straight up. If the probe does not pull out easily, turn aluminum cap until it comes off. Gently wiggle the silicone grommet until it loosens. When the grommet is loose, the probe should be easily pulled from the port. Replace the PTFE blank seal between the grommet and the metal washer when storing. Replace and re-tighten aluminum cap and repeat this procedure on the next probe. 8

Chapter 4: System Maintenance Care of the Multi-Probe Monitoring Chamber Although polycarbonate is a durable plastic, it can be easily scratched. Therefore, reasonable care should be used in handling and cleaning the unit. Abrasive cleaners should not be used. All sediment residues should be removed by immediately flushing and thoroughly rinsing. Organic solvents which attack the plastic should, of course, be avoided. The unit may be fully disassembled for cleaning and decontamination if desired. Because the sample is taken at a point in-line before the flow cell chamber, many users simply rinse the Multi-Probe Sampling system thoroughly with clean water, inside and out to clean. Any detergent solutions will be harmful to polycarbonates. Limit exposure to detergent solutions to under 1 (one) minute. Dilute mineral acids may be used without damage to the unit. With proper treatment, the unit will give long and satisfactory service. Polycarbonate is easily scratched and damaged with improper handling. Do not use abrasive cleansers on flowcell. Immediately remove sediment residues. Avoid contact with organic solvents or detergents. Disassembly of Flow Cell Chamber Body To disassemble, pull stainless clamp latch back until clamp is released. Unhook T bolt and remove clamp. For assembly, reverse procedures. When re-assembling flow cell chamber body, be sure to place gasket back between flow cell top and flow cell bottom. The clamp has been factory preset to the right size for the flow cell body and should not be re-adjusted. 9

Chapter 5: System Troubleshooting Problem: Leaking from around the probe Solutions: 1) Check grommet for correct size and make sure the metal washer has been used. Has unit been tightened down properly? Be sure not to over-tighten. 2) Check unit for cracks. If cracks are present and leaking, contact Geotech Environmental Equipment Inc. at 800-833-7958 for a replacement. Problem: Air is trapped in ports Solution: 1) Has air been purged? To purge, loosen cap while pumping sample water through the flow cell and allow air to escape, once done, re-tighten cap. Problem: Blow out plug keeps popping: Solution: 1) Double check your flow rate with the specifications of the Flow Cell. If you are exceeding the Flow Cell flow rate, you could be exceeding the 8 PSI limit for the blow out plug. Reduce your flow rates if possible, or contact Geotech Environmental Equipment Inc. at 800-833-7958 for possible solutions. 10

Chapter 6: System Specifications Dimensions: Inlet 3/8 Outlet 1/2 Flowcell leg length 12 Width with clamp 8 Grommets included accommodate the following diameter of probes.125 to.250,.250 to.375,.375 to 500,.500 to.675,.750 to.875 Grommet also available.875 to 1.00 Parts kit includes grommet sizes.500 to.675,.375 to.500,.875 to 1.00 Materials: Cell top medical grade polycarbonate Cell bottom (high volume) medical grade polycarbonate Cell bottom (low volume) machined acrylic O-ring medical grade silicone Clamp stainless steel Grommets medical grade silicone Gasket medical grade silicone Pressure relief valve medical grade silicone Legs anodized aluminum Leg end covers red neoprene 11

Chapter 7: System Schematic 12

Chapter 8: Replacement Parts List High Volume Flow Cell Part Number Part Description 17500004 Clamp, SS, 6.75 VBAND, AFH 52200004 Kit, Parts, HFC 22200015 Plug, Blowout, SIL, Red, 22200001 Disc, TFE, 1.00 /.03, FC 22200002 Disc, TFE, 1.50 /.03, FC 12200003 Grommet, NTL, 875 / 1.00FC 17200041 Hosebarb, NYL, 90D, ¼ x ⅜ MPT 17200039 Hosebarb, NYL, 90D, ½ x ⅜ MPT 52200007 Kit, Leg, AL6, Tripod, 60D, PK of 3 17500098 O-Ring, NTL, #013 52200001 Assy, Pressr, Vessel, Top, FC Low Volume Flow Cell Part Number Part Description 17500004 Clamp, SS, 6.75 VBAND, AFH 52200005 Kit, Parts, LFC 22200006 Grommet, SIL, 125 / 250, FC, Red 22200007 Grommet, SIL, 250 / 375, FC, Red 22200001 Disc, TFE, 1.00 /.03, FC 22200002 Disc, TFE, 1.50 /.03, FC 12200003 Grommet, NTL, 875 / 1.00FC 17200034 Hosebarb, NYL, ½ x ½ MPT 17200035 Hosebarb, NYL, ¼ x ½ MPT 57500003 Kit, Leg, AL6, Tripod, 3/pk, STRT 22200015 Plug, Blowout, SIL, Red, 22200016 Assy, Pressr, Vessel, ACR, BOT, LFC 17200036 Hosebarb, NYL, ⅜ x ½ MPT 52200001 Assy, Pressr, Vessel, Top, FC 22200012 Instruction Manual Accessories Part Number Part Description 57500010 Assy, TEE, Valve, PVC, 3-way 13

Notes 14

Notes 15

The Warranty For a period of one (1) year from date of first sale, product is warranted to be free from defects in materials and workmanship. Geotech agrees to repair or replace, at Geotech s option, the portion proving defective, or at our option to refund the purchase price thereof. Geotech will have no warranty obligation if the product is subjected to abnormal operating conditions, accident, abuse, misuse, unauthorized modification, alteration, repair, or replacement of wear parts. User assumes all other risk, if any, including the risk of injury, loss, or damage, direct or consequential, arising out of the use, misuse, or inability to use this product. User agrees to use, maintain and install product in accordance with recommendations and instructions. User is responsible for transportation charges connected to the repair or replacement of product under this warranty. Equipment Return Policy A Return Material Authorization number (RMA #) is required prior to return of any equipment to our facilities, please call 800 number for appropriate location. An RMA # will be issued upon receipt of your request to return equipment, which should include reasons for the return. Your return shipment to us must have this RMA # clearly marked on the outside of the package. Proof of date of purchase is required for processing of all warranty requests. This policy applies to both equipment sales and repair orders. FOR A RETURN MATERIAL AUTHORIZATION, PLEASE CALL OUR SERVICE DEPARTMENT AT 1-800-833-7958 OR 1-800-275-5325. Model Number: Serial Number: Date: Equipment Decontamination Prior to return, all equipment must be thoroughly cleaned and decontaminated. Please make note on RMA form, the use of equipment, contaminants equipment was exposed to, and decontamination solutions/methods used. Geotech reserves the right to refuse any equipment not properly decontaminated. Geotech may also choose to decontaminate equipment for a fee, which will be applied to the repair order invoice. 16

Geotech Environmental Equipment, Inc 2650 East 40 th Avenue Denver, Colorado 80205 (303) 320-4764 (800) 833-7958 FAX (303) 322-7242 email: sales@geotechenv.com website: www.geotechenv.com