Quattro FX Quattro FX for Her

Similar documents
Mirage FX. User Guide. English NASAL MASK

Mirage Micro. User Guide. English. nasal mask

Swift LT NASAL PILLOWS SYSTEM. User Guide English

User guide English r1 Quattro Air Amer Multi Multi Book.indb 1 14/07/ :30:10 AM

Fitting / Mise en place / Colocación / Ajuste

Mirage FX. User Guide. English NASAL MASK

Mirage Micro for Kids. nasal mask

Mirage Micro for Kids

Fitting / Mise en place / Colocación / Ajuste

Mirage Vista Nasal Mask

English USER GUIDE User guide

AirFit Nasal Mask. User guide N10. English

Mirage Quattro FULL FACE MASK

Mirage Micro. User Guide. English. nasal mask

Quattro Air Non-vented full face mask

English. ivolve Full Face Mask. User Manual

English USER GUIDE User guide

User Guide. English. Nasal Pillows System

Mirage FX. User Guide. English NASAL MASK

User Guide. English. Nasal Pillows System

Quattro FX Quattro FX for Her

Mirage Quattro FULL FACE MASK

Swift FX Nano Swift FX Nano for Her

C-1 C-7. C-6 Short air tubing Upper Velcro straps. C-a C-5 C-2 C-4 C-3 B-1 B-9 B-10 B-2 B-7 B-8 B-3 B-6 D-1 D-2 D-13 D-3 D-12 D-10 D-11 D-4 D-5 D-8

Full face mask. User guide English

Swift FX Bella. User Guide. + Swift FX for Her HEADGEAR NASAL PILLOWS SYSTEM

Mirage Liberty. User Guide 61850/ APAC ENG MIRAGE LIBERTY USER r2 cover.qxp 3/04/2007 4:39 PM Page 1. English FULL FACE MASK

Full face mask. User guide. English

Hospital masks. User guide. English

EasyLife INSTRUCTIONS FOR USE. Respironics Inc Murry Ridge Lane Murrysville, PA USA JDH 3/25/10

Mirage FX. User Guide. English NASAL MASK

Nasal mask. User guide. User guide English

Instructions for Use. OptiLife Nasal Lab Mask

User guide English book.indb 1 14/07/ :51:19 AM

2010 Koninklijke Philips Electronics N.V. All rights reserved. INSTRUCTIONS FOR USE

Invacare Twilight II Nasal Mask

AirFit Nasal Mask. User guide N10. English

Swift FX Nano Swift FX Nano for Her

Mirage Activa LT. User Guide. English. nasal mask

EasyFit Lite Nasal Mask, Silicone. Nasal Mask. EasyFit Lite Nasal Mask. Device Description and Instructions for Use. Caution:

Pixi. User Guide. Pixi TM PEDIATRIC MASK. English. pediatric MASK

ComfortGel Full. Full Face Mask

Ultra Mirage II Nasal Mask

EasyFit SilkGel Full Face Mask

Full face mask. User guide. English

EasyFit Full Face Mask, Silicone EasyFit Full Face Mask, Gel

Full face benefits in a compact size

Contents Warnings, Cautions, and Notes Contents of the Package Introduction to the Harmony S/T A Tour of the Harmony S/T...

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

English Please read the entire Information and Welcome Guides before using your device.

Micro Dial-Flowmeter. Instructions for Use

Oxygen Dialflow Meter. Instructions for Use

Mirage Kidsta Nasal Mask

English Please read the entire Information and Welcome Guides before using your device.

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

U S E R M A N U A L. Model: PM4300 Series SAVE THESE INSTRUCTIONS

S8 Lightweight II. User Guide. English POSITIVE AIRWAY PRESSURE DEVICE

DRAFT U S E R M A N U A L CAUTION. Model: 19MFA1001 Series. Federal (USA) law restricts this device to sale by or on the order of a physician.

Please read the entire Information and Welcome Guides before using your device.

S8 Series II. S8 AutoSet Spirit II S8 AutoScore II. User Guide. English POSITIVE AIRWAY PRESSURE DEVICES

Pressure Regulator. Instructions for Use

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

Manual: Biphasic Positive Airway Pressure (BiPAP) Ventilation

CPR MEDICAL DEVICES INC. OPERATING MANUAL FOR RESUSCITATOR

Rev. B. Operating Instructions

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

USER MANUAL SAVE THESE INSTRUCTIONS. 300 Held Drive Tel: (+001) Northampton, PA USA Fax: (+001) ISO Certified

OPERATOR S MANUAL. Pediatric/Infant cap-one Mask YG-232T/YG-242T A. General. Safety Information WARNING WARNING WARNING. Components WARNING

Oxygen Dialflow Meter. Instructions for Use

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

Log on now to to find useful tips on managing your treatment. Mirage Swift II. Nasal Pillows System. User Guide.

SodaStream is the modern way to enjoy delicious bubbles. without the bottles. No more lugging or storing heavy

Dialflow Regulator. Instructions for Use

DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER)

Model 1700 Patient Operating Instructions. Model 1700

SOTR Special Operations Tactical Respirator

BlenderBuddy 2. Operating Manual & Instructions For Use ENGLISH R233M01 REV. A

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% ADMINISTRATION SYSTEM (01EQ7000E) DEMAND VALVE (01EQ7001E) O-TWO MEDICAL TECHNOLOGIES INC.

CPR MEDICAL DEVICES INC. OPERATING MANUAL

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% USER ADMINISTRATION SYSTEM 01EQ7000E DEMAND VALVE 01EQ7001E TABLE OF CONTENTS

FLOWMETER MODELS: 1MFA, 4MFA, 6MFA and 8MFA Series SAVE THESE INSTRUCTIONS

Dual Release Walkers 6291 Series. 1 General. 1.1 Symbols WARNING

Complex Care Hub Manual: Oxygen Therapy

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

OWNER S MANUAL POWERBREATHER PB01 FRANÇAIS ESPAÑOL

Filter cartridge protection class A2 Organic vapours, with boiling point above 65 C, to 50X OEL or 1000 ppm, whichever is the lower.

Operators Manual. Supera Floor Stand Anesthesia Machine M1000. Models: M1000 Basic Non-rebreathing M1200 Basic M1200

VENTI-O 2 plus. O 2 switching valve for: VENTImotion from serial number 4000 VENTIlogic from serial number 4000 VENTImotion 2

CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1

QUICK START GUIDE. Please read this Quick Start Guide before using the Sparkling Water Maker.

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

Entry to these spaces must be rigorously controlled to prevent serious injury or death.

M5400 Operators Manual

RG3100 and RG3100Ice Regulator System

AUTOVENT 4000 VENTILATOR

User manual STARLOCK. Careways International - Innovation Quality Performance

TactAir PCP Fill Kit/Adapter. Operation Manual

ROPV R40 E Series User Manual

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

ISO INTERNATIONAL STANDARD. Sleep apnoea breathing therapy Part 2: Masks and application accessories

Transcription:

Quattro FX Quattro FX for Her FULL FACE MASK User Guide English

Did you know? Replacing your mask and supplies is one of the most important steps in maintaining effective therapy. Replace when... The cushion is no longer clear and transparent. The cushion is cracked, torn or damaged in any way. The headgear is stretched and needs to be tightened more than when it was new. What to do... Consult your equipment provider to learn what replacement schedule may be available through your insurance policy.

Quattro FX Quattro FX for Her FULL FACE MASK / MASQUE FACIAL / MASCARILLA FACIAL / MÁSCARA FACIAL Fitting / Mise en place / Colocación / Colocação e ajuste 1 2 3 4 5 6 i

Headgear position / Position du harnais / Posición del arnés / Posição do arnês Cushion check / Vérification de la bulle / Revision de la almohadilla / Verificação da almofada Disassembly / Démontage / Desmontaje / Desmontagem 1 1 2 3 4 5 6 ii

7 Reassembly / Remontage / Montaje / Remontagem 1 2 3 4 5 6 7 8 iii

Quattro FX Quattro FX for Her A 2 3 1 4 13 6 7 5 14 11 8 12 10 9 B iv

Mask components / Composants du masque / Piezas de la mascarilla / Componentes da máscara Item / Article / Artículo / Item Description / Description / Descripción / Descrição Part number / Code produit / Número de pieza / Código do produto Quattro FX Quattro FX for Her 1 Spring frame / Entourage flexible / Armazón elástico / Armação flexível 2 Vent / Orifice de ventilation / Ventilación / Respiradouro 3 Cushion / Bulle / Almohadilla / Almofada 4 Frame / Entourage rigide / Armazón / Armação 5 Soft sleeves / Sangles souples / Fundas blandas / Luvas maleáveis 6 Ports cap / Bouchon d entrées / Tapón de los puertos / Tampa das portas 7 Headgear clip / Clip d attache du harnais / Broche del arnés / Presilha do arnês 8 Headgear / Harnais / Arnés / Arnês 61734 (S) 61733 (M) 61738 (L) 9 Spring frame support / Support de l entourage flexible / Soporte del armazón elástico / Suporte da armação flexível 10 Swivel / Pièce pivotante / Pieza giratoria / Peça giratória 61721 (S) 61722 (M) 61723 (L) 11 Elbow / Coude / Codo / Cotovelo 62506 (S) 62507 (STD) 12 Valve / Valve / Válvula / Válvula v

13 Valve clip / Clip de la valve / Broche de la válvula / Presilha da válvula 14 Valve & clip / Valve et clip / Válvula y broche / Válvula e presilha A Complete system / Système complet / Sistema completo / Sistema completo 61700 (S) 61701 (M) 61702 (L) 62501 (S) 62502 (M) B Frame system / Support / Sistema del armazón / Sistema da armação S Small / Small / Pequeño/a / Pequeno(a) M Medium / Medium / Mediano/a / Médio(a) L Large / Large / Grande / Grande 61724 (S) 61725 (M) 61726 (L) 62513 (S) 62514 (M) vi

English Quattro FX Quattro FX for Her FULL FACE MASK Thank you for choosing the Quattro FX/Quattro FX for Her. Please read the entire manual before use. Intended use The Quattro FX/Quattro FX for Her channels airflow noninvasively to a patient from a continuous positive airway pressure (CPAP) or bilevel device. The Quattro FX/Quattro FX for Her is: to be used by adult patients (> 66 lb/30 kg) for whom positive airway pressure has been prescribed intended for single-patient re-use in the home environment and multipatient re-use in the hospital/institutional environment. English WARNING The mask must be used under qualified supervision for users who are unable to remove the mask by themselves. The mask may not be suitable for those predisposed to aspiration. The elbow and valve assembly have specific safety functions. The mask should not be worn if the valve is damaged as it will not be able to perform its safety function. The valve should be replaced if it is damaged, distorted or torn. The vent holes must be kept clear. This mask should only be used with CPAP or bilevel devices recommended by a physician or respiratory therapist. The mask should not be used unless the device is turned on. Once the mask is fitted, ensure the device is blowing air. Explanation: CPAP and bilevel devices are intended to be used with special masks (or connectors) which have vent holes to allow continuous flow of air out of the mask. When the device is turned on and functioning properly, new air from the device flushes the exhaled air out through the mask vent holes. However, when the device is not operating, insufficient fresh air will be provided through the mask, and the exhaled air may be rebreathed.rebreathing of exhaled air for longer than several minutes can, in some circumstances, lead to 1

suffocation. This applies to most models of CPAP or bilevel devices. Follow all precautions when using supplemental oxygen. Oxygen flow must be turned off when the CPAP or bilevel device is not operating, so that unused oxygen does not accumulate within the device enclosure and create a risk of fire. Oxygen supports combustion. Oxygen must not be used while smoking or in the presence of an open flame. Only use oxygen in well ventilated rooms. Remove all packaging before using the mask. Ensure the soft sleeves are fitted at all times during use. Using your mask When using your mask with ResMed CPAP or bilevel devices that have mask setting options, refer to the Technical specifications section in this user guide for mask selection options. For a full list of compatible devices for this mask, see the Mask/Device Compatibility List on www.resmed.com on the Products page under Service & Support. If you do not have internet access, please contact your ResMed representative. Note: If you experience airway dryness or irritation, using a humidifier is recommended. 2

Fitting Prior to fitting your mask, remove the spring frame support from the rear of your mask and retain for future use. The Fitting illustrations section in this guide show the sequence for obtaining the best fit and comfort in using your mask. Fitting steps English 1. With both lower headgear clips released, position your mask at an angle against your face, ensuring that the top of the cushion contacts your nasal bridge first. 2. Keeping the upper position of the mask in place, swing the lower half of the mask down against your face so that it rests halfway between your bottom lip and chin. 3. Hold the mask firmly against your face and pull the headgear over your head. 4. Bringing the lower straps below your ears, clip the headgear into the lower part of the spring frame. 5. Unfasten the Velcro, pull the upper headgear straps evenly until they are comfortable and firm, and reattach the Velcro. 6. Repeat step 5 with the lower headgear straps. Headgear and cushion check Ensure your headgear is positioned correctly. Refer to the Headgear check illustrations in this user guide. The Quattro FX/Quattro FX for Her cushion is designed to sit mid-bridge. Refer to the Cushion check illustrations for correct positioning. Removing your mask To remove your mask, disconnect the lower headgear clips and pull the mask and headgear up over your head. 3

Disassembly Before disassembling your mask, detach the air tubing and unclip the lower headgear clips from the spring frame. Refer to the disassembly illustrations in this guide. Disassembly steps 1. Remove the elbow assembly from the mask. 2. Gently pull the spring frame away from the frame. Remove the soft sleeves from the spring frame. 3. Gently separate the cushion from the frame. 4. Remove the ports cap. 5-6. Remove the valve clip and detach the swivel from the elbow. 7. Peel the valve away from the valve clip. Do not pull on the membrane to remove the valve. Reassembly Refer to the reassembly illustrations in this guide. Reassembly steps 1. Insert the valve into the clip. 2. Push the valve clip onto the elbow and insert the swivel into the end of the elbow. 3. Replace the ports cap. 4. Fit the cushion into the channel of the frame. Fit the top section first, then work your way around, pushing the cushion into the frame. Ensure that the cushion is not twisted or distorted around the frame. 5. Replace the soft sleeves onto the spring frame and align the spring frame with the frame. 6. Starting at the top, gently push and click the spring frame into the frame. 7. Gently push and click each side of the lower spring frame into the frame. 8. Replace the elbow into the mask assembly. 4

Cleaning your mask in the home Your mask and headgear should only be gently handwashed. Daily/After each use: Disassemble the mask components according to the disassembly instructions. Thoroughly clean the separated mask components (excluding headgear), by gently rubbing in warm (approximately 86 F/30 C) water using mild soap. To optimize the mask seal, facial oils should be removed from the cushion after use. Use a soft bristle brush to clean the vent. Inspect each component and if required, repeat washing until visually clean. Rinse all components well with drinking quality water and allow to air dry out of direct sunlight. When all components are dry, reassemble according to the reassembly instructions. Weekly: Handwash the headgear. It may be washed without being disassembled. Handwash the soft sleeves. English WARNING Do not use aromatic-based solutions or scented oils (eg, eucalyptus or essential oils), bleach, alcohol or products that smell strongly (eg, citrus) to clean any of the mask components. Residual vapours from these solutions can be inhaled if not rinsed thoroughly. They may also damage the mask, causing cracks. CAUTION If any visible deterioration of a system component is apparent (cracking, crazing, tears etc), the component should be discarded and replaced. Avoid connecting flexible PVC products (eg, PVC tubing) directly to any part of the mask. Flexible PVC contains elements that can be detrimental to the materials of the mask, and may cause the components to crack or break. 5

Reprocessing the mask between patients This mask should be reprocessed when used between patients. Cleaning, disinfection and sterilization instructions are available from the ResMed website, www.resmed.com/masks/sterilization/americas. If you do not have internet access, please contact your ResMed representative. Troubleshooting Problem/possible cause Mask is uncomfortable Headgear straps are too tight. Mask could be the wrong size. Headgear is touching top of ears. Cushion is riding up the face during use. Spring frame is sitting too close to the eyes. Mask is too noisy Ports cap or elbow incorrectly inserted. Vent is blocked or partially blocked. Solution The cushion membrane is designed to inflate against your face to provide a comfortable seal with low headgear tension. Adjust straps evenly. Ensure that the headgear straps are not too tight and that the cushion is not crushed or creased. Talk to your clinician to have your face size checked against fitting template. Note that sizing across different masks is not always the same. The Quattro FX/Quattro FX for Her cushion is designed to sit mid-bridge. Remove and refit your mask according to the instructions. Check that the top and bottom headgear straps are correctly positioned. Ensure that the Velcro tab is correctly aligned with headgear material and not cutting into top of ear. Check headgear positions against the instructions. Headgear should not be worn too far back on your head. Headgear may be the wrong size. If the problem persists, talk to your clinician. Your mask could be the wrong size. Talk to your clinician to have your face size checked against the fitting template. Remove the ports cap and elbow from your mask, then reassemble according to the instructions. Clean with a soft bristle brush until the vent is clear. 6

Problem/possible cause Mask leaks around the face Cushion membrane is creased or folded. Cushion incorrectly inserted into frame. Mask could be the wrong size. Spring frame incorrectly fitted to frame. Solution Turn off the CPAP or bilevel device and remove mask. Refit your mask according to the instructions. Ensure you position the cushion correctly on your face before pulling headgear over your head. Do not slide mask down your face during fitting as this may lead to folding or curling of the cushion. Remove cushion from frame and reinsert starting at the top. Line up raised section on cushion with recess in top of frame. Ensure the alignment markers at bottom corners of the cushion line up with the indent features on frame. Ensure cushion membrane looks even before refitting. If the problem persists, talk to your clinician. Talk to your clinician to have your face size checked against fitting template. Note that sizing across different masks is not always the same. The Quattro FX/Quattro FX for Her cushion is designed to sit mid-bridge. Remove the spring frame from the frame, then reassemble according to the instructions. English 7

WARNING The technical specifications of the mask are provided for your clinician to check that they are compatible with the CPAP or bilevel device. If used outside specification or if used with incompatible devices, the seal and comfort of the mask may not be effective, optimum therapy may not be achieved, and leak, or variation in the rate of leak, may affect the CPAP or bilevel device function. Discontinue using this mask if you have ANY adverse reaction to the use of the mask, and consult your physician or sleep therapist. Using a mask may cause tooth, gum or jaw soreness or aggravate an existing dental condition. If symptoms occur, consult your physician or dentist. As with all masks, some rebreathing may occur at low CPAP pressures. Refer to your CPAP or bilevel device manual for details on settings and operational information. At a fixed rate of supplemental oxygen flow, the inhaled oxygen concentration varies, depending on the pressure settings, patient breathing pattern, mask, point of application and leak rate. This warning applies to most types of CPAP devices. 8

Technical specifications Pressure flow curve Vent flow rate (L/min) 90 80 70 60 50 40 30 20 10 0 The mask contains passive venting to protect against rebreathing. As a result of manufacturing variations, the vent flow rate may vary. 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 Mask pressure (cm H 2 O) Pressure (cm H 2 O) 4 22 8 32 12 41 16 48 20 54 24 60 28 66 30 69 Flow (L/min) English Dead space information Therapy pressure Resistance with Anti Asphyxia Valve (AAV) closed to atmosphere. Inspiratory and expiratory resistance with Anti Asphyxia Valve (AAV) open to atmosphere. Environmental conditions Gross dimensions Small: Medium: Large: Mask setting options Physical dead space is the empty volume of the mask to the end of the swivel. Using the large cushions it is 243 ml. 4 to 30 cm H 2 O Drop in pressure measured (nominal) at 50 L/min: 0.1 cm H 2 O at 100 L/min: 0.5 cm H 2 O Inspiration at 50 L/min Expiration at 50 L/min 0.7 cm H 2 O 0.7 cm H 2 O Operating temperature: +41 F to 104 F (+5 C to +40 C) Operating humidity: 15% to 95% non-condensing. Storage and transport: -4 F to 140 F( -20 C to +60 C) Storage and transport humidity: up to 95% non-condensing. Mask fully assembled with elbow assembly no headgear. 4.76 (H) x 6.93 (W) x 5.67 (D) 121mm (H) x 176 mm (W) x 144 mm (D) 5.12 (H) x 6.93 (W) x 5.67 (D) 130 mm (H) x 176 mm (W) x 144 mm (D) 5.51 (H) x 6.93 (W) x 5.67 (D) 140 mm (H) x 176 mm (W) x 144 mm (D) Select MIR FULL (if available), otherwise select FULL FACE as the mask option. 9

Notes: The mask system does not contain PVC, DEHP or phthalates. This product does not contain natural rubber latex. The manufacturer reserves the right to change these specifications without notice. Storage Ensure that the mask is thoroughly clean and dry before storing it for any length of time. Store the mask in a dry place out of direct sunlight. To ensure optimum care of your mask, fit the spring frame support when traveling. Disposal This mask does not contain any hazardous substances and may be disposed of with your normal household refuse. Symbols Caution, consult accompanying documents; LOT Batch code; REF Catalogue number; Temperature limitation; Humidity limitation; Does not contain natural rubber latex; Manufacturer; Indicates a Warning or Caution and alerts you to a possible injury or explains special measures for the safe and effective use of the device; Keep away from rain; This way up; Fragile, handle with care; Rx Prescription only (In the US, Federal law restricts these devices to sale by or on the order of a physician.) 10

Limited warranty ResMed Ltd (hereafter ResMed ) warrants that your ResMed mask system (including mask frame, cushion, headgear and tubing) shall be free from defects in material and workmanship from the date of purchase for the period of 90 days or in the case of disposable masks the maximum use period. This warranty is only available to the initial consumer. It is not transferable. If the product fails under conditions of normal use ResMed will repair or replace, at its option, the defective product or any of its components. This limited warranty does not cover: a) any damage caused as a result of improper use, abuse, modification or alteration of the product; b) repairs carried out by any service organization that has not been expressly authorized by ResMed to perform such repairs; and c) any damage or contamination due to cigarette, pipe, cigar or other smoke. Warranty is void on product sold, or resold, outside the region of original purchase. Warranty claims on defective product must be made by the initial consumer at the point of purchase. This warranty replaces all other expressed or implied warranties, including any implied warranty of merchantability or fitness for a particular purpose. Some regions or states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. ResMed shall not be responsible for any incidental or consequential damages claimed to have resulted from the sale, installation or use of any ResMed product. Some regions or states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from region to region. For further information on your warranty rights, contact your local ResMed dealer or ResMed office. English 11

1 2 S W I N G 3 4 5 6 Manufacturer: ResMed Ltd 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia See www.resmed.com for other ResMed locations worldwide. Protected by patents: AU 777033, AU 785376, EP 1187649, EP 1314445, EP 1582230, EP 1640034, HK 1057714, JP 4354664, JP 4607913, NZ 538699, US 6439230, US 6581594, US 6823865, US 7159587, US 7926487, US 7669599. Other patents pending. Protected by design registrations: EU 1225411. Others pending. Quattro is a trademark of ResMed Ltd. 2017 ResMed Ltd.

1 2 S W I N G 3 4 5 6 618179/2 2017-09 QUATTRO FX QUATTRO FX FOR HER USER amer ENG 618179 Global leaders in sleep and respiratory medicine www.resmed.com