Field Adjustable Pressure Reducing (URFA)

Similar documents
1 Exam Prep. Tabs and Highlights

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY PNEUMATIC RELEASE. 1. DESCRIPTION (Refer to Figures 1, 2 or 3.

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

Flow Material Length. Weight GPM LPM. Style 3095

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE

ELKHART BRASS MANUFACTURING COMPANY

VERTICAL BLADDER TANK

BUTTERFLY VALVES. Toll Free (877) - ICFLUID -2-

Vertical Bladder Tanks

TECHNICAL DATA Q= C. Table 1 - Specifications

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

HORIZONTAL BLADDER TANK

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

TECHNICAL DATA. System water supply pressure enters the priming chamber of the deluge valve (A.1) through the 1/4 (8 mm) priming line, which

Model MTB-ASME Vertical Bladder Tanks

Data Sheet Issue A

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8" and 1/4" PTF Port Sizes. Air line equipment.

Model MTB-ASME Vertical Bladder Tanks

Bermad Pressure Reducing. Model: 42T

B74G - EXCELON Modular System General purpose filter/regulator

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA. Dry 132a. October 1, 2008

Technical Data. UL Listing is based on the following criteria:

TECHNICAL DATA. than the water inlet pressure to the concentrate

Horizontal Bladder Tanks

TECHNICAL DATA. Table 1 - Specifications

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

TECHNICAL DATA. Page 1 of 12

III. Identify the initial installation requirements for standpipe systems

PRESSURE REGULATOR GUIDE

TECHNICAL DATA. Trimpac 244a. September 16, 2013

CROSS REFERENCE PARTS LIST T & S

Water valve Type WVO. Data sheet MAKING MODERN LIVING POSSIBLE

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

DF-5 48 Inch Gas Train 10/09/2012

Model MTB-ASME Horizontal Bladder Tanks

ACME Connectors and Fittings Extended Type Hose Couplings for Vapor and Liquid Service A7571 and A7575 Series

EPOXY FITTINGS DIMENSIONS

Features. Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

Butterfly Control Valve. DMK/6 Series

TECHNICAL DATA CAUTION

N2 BLAST Datasheet Preaction single interlock electric c/w N 2 Blast Nitrogen generating system Remote controlled unit

TECHNICAL DATA. Trimpac 257a. September 16, 2013

Wet pipe low flow foam/water system

TECHNICAL DATA. Trimpac 256a. October 31, 2013

Liquid Level Controls

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

CAST IRON VALVES FLOAT VALVE

FireLock NXT Dry Valve. System No. Submitted By Spec Sect Para Location Date Approved Date

Instruction Manual 742 5/1/2009. Eclipse Ratio Regulators ES Series Version 1

Pressure Independent Control Series

Model DDX-LP Dry Pipe Valve System 8 (200mm) Features. Differential latching clapper-type, lighweight, dependable construction.

MyControl Bathing System Signature Series

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Models: C62/63/64-A/D

V43 Pressure Actuated Water Regulating Valve

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

Gauge Valves / Multi-Port Valves & Air Distribution Manifolds

TECHNICAL DATA. Q= Cv S

diaphragm In-line service One pilot valve sub-assembly provides for any outlet set pressure, that is, 80 to 225 psi (5,5 to 15,5 bar)

BERMAD Waterworks. Pressure Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features

Excess Flow Valves. General Information. How They Work. An Explanation and Warning. Proper Installation

V46 Series 2-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

TotalPac X Single interlock Preaction system Electric release

Features. Model EX Low Pressure Dry Pipe Valve System 2 (DN50), 2½ (DN65), 3 (DN80), 76 mm, 4 (DN100 ), 6 (DN150), 165 mm & 8 (DN200)

Full Range Pressure Compensating Variable Flow Control

WaterSource Heat Pump Hose Kit Performance Specification-Summary

FOAM TANK (1/2) DATA SHEET

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Section 3000 CONVEYOR CHAIN LUBRICATION SCHEMATIC...39 AIR OPERATED SPRAY DISPENSERS - CENTRAL ACRYLIC RESERVOIR Section 3000 Index

CALEFFI. Ball zone valves. series /03 GB

End Connection. Thread x Thread N/A N/A N/A N/A Flange x Flange N/A

IN-LINE CHECK VALVES CIT-02 / 03 / 06 / 10 (1/4,3/8,3/4,1-1/4) RIGHT ANGLE CHECK VALVES CRT / CRG-03 / 06 / 10 (3/8,3/4,1-1/4)

B84G - Excelon Plus Modular System General purpose filter/regulator

Master Control Systems, Inc. Variable Speed Fire Pump Controllers

TECHNICAL DATA. Q = C v P S

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

Master Control Systems, Inc. Variable Speed Fire Pump Controllers

BERMAD Waterworks. Pressure-Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features

gpphighpressure.com (417) BALL VALVES *Dimensions are subject to change and are considered reference.

Operator: Save these instructions for future use!

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

The TYCO Model PRV-1 Pressure. Reducing Valves described herein must be installed and maintained in compliance with this document and with the

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Precision and Instrument Regulators 1/4" port size

SINGLE VALVE WITH LOW-FLOW BYPASS

BERMAD Waterworks. Level Control Valve with Bi-Level Vertical Float. 700 Series Model B. Features and Benefits. Major Additional Features

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

Transcription:

IL JUSTL PRSSUR RUING 10-1 ield djustable Pressure Reducing (UR) lkhart s UR valve is a true pressure reducing valve, operated automatically by inner hydraulic controls. While the valves are preset at the factory, they are field adjustable allowing you to tailor the pressure to your needs. They feature manual valve open and close, as well as pressure adjustment all of which require extremely low torque to change due to the patent pending design. Inlet pressure up to 400 psi (27.58 bar) is controlled under all flow and no-flow conditions. Valve size and weight permit installation in significantly tighter areas and smaller hose cabinets (those used for 1 1 /2 or 2 1 /2 valves) allowing savings of both space and money. The UR also functions as a floor control valve in automatic sprinkler systems as well as a standpipe valve or hose valve for lass I and lass III systems. UR Series valves not intended for use in salt water applications.

IL JUSTL PRSSUR RUING INLT OUTLT TYP RT. SIZ SIZS IMNSIONS (INHS) INISH 2 1 /2 21 /2 UL losed Open rass hrome Wt. NPT* (NPT)* M(NHT) Listed ast Pol Pol (Lbs.) MOL 13 5 /8 11 5 /8 14 1 /4 12 1 /4 2 5 /8 3 1 /4 5 4 1 /4 o s o o 26 1 /4 UR-20-2.5 1 13 5 /8 11 5 /8 14 1 /4 12 1 /4 2 5 /8 3 5 /8 5 4 1 /4 s o o 33 UR-25-2.5 2 14 1 /2 11 29 /32 15 1 /8 12 1 /4 3 1 /2 4 5 4 1 /4 o s o o 33 UR-20S-2.5 3 ngled Straight KY s = standard o = option * Grooved connection available for inlet or outlet use add 1.44 per connection. igure 1 igure 2 igure 3 UR-20-2.5 UR-25-2.5 UR-20S-2.5 ig. 1 ig. 2 ig. 3 Integral Superv. Switch PROUT HIGHLIGHTS UR features include: Manual open-close requires less than 15 lbs. of torque Pressure rated up to 400 psi (27.58 bar) low rated up to 500 gpm (1893 lpm) Open-lose indication from 2 view directions olor-coded pressure reduction label Tapped for pressure gauge on both inlet and outlet side of valve Tamper-resistant protection UL Listed as a check valve for use in dual riser systems Optional integral supervisory switch (alarm) mounts directly to valve with no bracket required Optional integral supervisory switch (alarm) is available either OPN TO SIGNL or LOS TO SIGNL With the UR valve in the full open position the supervisory switch contacts are LOS. When the valve hand wheel is turned in the closed direction the supervisory switch contacts OPN. This is defined as OPN TO SIGNL. With the UR valve in the full open position the supervisory switch contacts are OPN. When the valve hand wheel is turned in the closed direction the supervisory switch contacts LOS. This is defined as LOS TO SIGNL. ITIONL INORMTION Includes adjustment rod. THRS Valve inlet information is NPT unless otherwise specified. Special threads available through adapter use. See index T-13 for alternative outlet thread options. IGUR 10-2

PRSSUR RUING 10-3 Pressure Reducing (Pressure-Matic) lkhart s Pressure-Matic is a true pressure reducing valve, operated automatically by inner hydraulic controls. No diaphragms, springs or outside controls are involved with the unit, the action being completely dependent upon conditions at the nozzle or sprinkler system. lkhart rass offers 18 different valve pressure types/ranges for building systems. Inlet pressure up to 400 psi (27.58 bar) is controlled under all flow and no-flow conditions. The UR valve series may be used as a standard shut-off. The valves are completely tamperproof. They fit all existing cabinets where 1 1 /2 or 2 1 /2 valves are currently in use. Pressure-Matic valves can be used for/in: loor ontrol Valve Standpipe System utomatic Sprinkler Systems UL Listed as a check valve for use in dual riser systems Visual Status Indicator Optional Supervisory Switch racket 400 psi rating UR Series valves not intended for use in salt water applications.

PRSSUR RUING IMNSIONS RSS INLT SIZS OUTLT SIZS TYP RT. (Inches) INISH emale emale Male (NPT) (NPT) (NHT) UL 1 1 /2 2 1 /2 1 1 /2 2 1 /2 1 1 /2 2 1 /2 ng Str Listed Min Max MOL 7 3 /4 8 1 /4 4 2 1 /2 3 1 /2 2 3 /16 1 7 /8 s o o 7 1 /2 UR-20-1.5 1 7 3 /4 8 1 /4 4 2 7 /16 3 1 /2 2 3 /16 1 7 /8 s o o 7 1 /2 UR-25-1.5 2 11 11 5 /8 5 2 5 /8 5 7 /8 3 1 /4 2 13 /16 s o o 18 1 /2 UR-20-2.5 1 10 9 /16 11 3 /8 5 2 5 /8 5 7 /8 3 3 /8 2 13 /16 s o o 18 1 /2 UR-25-2.5 2 12 3 /16 12 13 /16 5 10 to 10 1 /2 5 7 /8 4 7 1 /2 s o o 26 1 /2 UR-20S-2.5 3 KY s = standard o = option *Partial polished UR-20 ast Polished* hrome* Weight (Lbs.) UR-20S IGUR igure 1 igure 3 (SWING RIUS) 10-4 (SWING RIUS) UR-25 ig. 1 IGRM UR20/25 ig. 3 igure 2 (SWING RIUS) ig. 2 ITIONL INORMTION ustomer must fill out valve data sheet on page G-8, factory setting required. alculator for determining valve pressure range is available from lkhart rass. Please inquire with our sales staff or see our website. THRS Valve inlet information is NPT unless otherwise specified. See index T-13 for alternative outlet thread options.

PRSSUR RSTRITING Pressure Restricting lkhart s pressure restricting valves all feature rugged cast brass construction in your choice of finishes. The pressure restricting valves feature rubber seats and are rated for use at 175 psi (12.15 bar). lthough factory setting is recommended, all the pressure restricting valves are field-settable. Pressure restricting valves: Reduce pressure under flowing conditions llow fire departments to override settings in emergency conditions 10-5 UP Series valves not intended for use in salt water applications.

PRSSUR RSTRITING INLT OUTLT RTII- RSS IMNSIONS SIZS SIZS TIONS INISH (Inches) emale emale Male Height UL hrome Swing Weight 1 1 /2 2 1 /2 1 1 /2 2 1 /2 1 1 /2 2 1 /2 Listed ast Polished Polished Radius Open losed (Lbs.) MOL s o o 2 1 /2 2 3 /16 4 7 7 /8 6 7 /8 6 UP-20-1.5 1 s o o 3 5 /8 3 1 /4 5 11 9 3 /8 11 3 /4 UP-20-2.5 1 s o o 2 1 /2 2 1 /8 4 7 7 /8 6 7 /8 6 UP-25-1.5 2 s o o 3 5 /8 3 1 /4 5 11 9 3 /8 11 3 /4 UP-25-2.5 2 KY s = standard o = option UP-20 IGRM IGUR igure 1 10-6 ig. 1 UP-25 igure 2 ITIONL INORMTION ll valves can be factory set. To order any of the valves listed here factory set, customer must provide residual inlet pressure, desired residual outlet pressure, and flow rate. Please see ordering form on page G-8. OTHR PROUTS or valves that reduce pressure in no-flow situations please see our Pressure- Matic (page 10-3) or UR (page 10-1) valves. ig. 2 THRS emale inlet and outlet information is in NPT unless otherwise specified. Male outlet standard is NHT.ontact lkhart rass for alternative outlet thread options.

NGL ngle lkhart s angle valves all feature rugged cast brass construction in your choice of finishes. dditionally, all feature rubber seats and are rated at 300 psi (20.68 bar). 10-7 U Series valves not intended for use in salt water applications.

NGL INLT OUTLT RTII- RSS IMNSIONS SIZS SIZS TIONS INISH (Inches) emale emale Male Height hrome M UL Pol- Pol- Weight 1 1 /2 2 1 /2 1 1 /2 2 1 /2 1 1 /2 2 1 /2 pp d Listed ast ished ished Open losed (Lbs.) MOL s o o 2 1 /2 2 3 /16 4 7 7 /8 6 7 /8 6 U-20-1.5 1 igure 1 s o o 3 5 /8 3 1 /4 5 11 9 3 /8 11 3 /4 U-20-2.5 1 s o o 2 1 /2 2 3 /16 4 7 7 /8 6 7 /8 6 U-25-1.5 2 s o o 3 5 /8 3 1 /4 5 11 9 3 /8 11 3 /4 U-25-2.5 2 KY s = standard o = option U-20 Swing Radius IGRM IGUR 10-8 ig. 1 U-25 igure 2 ig. 2 ITIONL INORMTION THRS Valve inlet information is in NPT unless otherwise specified. See index T-13 for alternative outlet thread options.