USER MANUAL Version: 1/2017

Similar documents
DIFFERENTIAL PRESSURE REGULATING VALVE

DIFFERENTIAL PRESSURE REGULATING VALVE zcon

DIFFERENTIAL PRESSURE REGULATING VALVE zcon

USER MANUAL. 1. Principle of operation. 2. Delivery condition. SPRING-LOADED SAFETY VALVES zarmak. Edition: 07/2016 Date: V (ex.

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Installation & Operation Manual Proven Quality since 1892

Engineering Data Sheet

Pressure Reducing Valve for Steam Type 2333 A

USER MANUAL. 781T (ex. 781) 776 ( ex. 775-I)

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Rp [ ] Sv min. [ ] C215QP-B 15 1/ C215QP-D 15 1/ C220QP-F 20 3/ [ ]

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

AVP-F. p setting range (bar) Code No. 003H6200

Mounting and Operating Instructions EB 2555 EN. Self-operated Pressure Regulators. Pressure Reducing Valves Type 50 ES Type 50 EM.

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

STAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Manual Brass Shut-Off Valve DN10 through DN22

Type overview. R B2 en-gb subject to changes 1

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Mounting and Operating Instructions EB EN. Self-operated Pressure Regulators. Type 2335 Excess Pressure Valve with pilot valve

Mounting and Operating Instructions EB 3009 EN. Self-operated Regulators. Type RS Check Valve (backflow protection)

Differential pressure controller (PN 16) AVPL return mounting, adjustable setting

A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions

Differential pressure controller (PN 16) AVPL - return mounting, adjustable setting

Manual Actuated Boiler Blowdown Valves

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

Automatic balancing valves ASV

STAD-C. Balancing valves DN 15-50

Pressure Independent Control Series

Steam Trap BK BK 212-ASME. Original Installation Instructions English

BCV31 DN40 - Blowdown Control Valve

PC3_ and PC4_ Pipeline Connectors

DS05C,D,G Dial Set Pressure Regulating Valves

Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN

STAD. Balancing valves DN 15-50

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

Mounting and Operating Instructions EB 2172 EN. Series 43 Temperature Regulators. Type 43-5 and Type Type Type 43-6

Pressure relief valve

Installation, operation & maintenance manual - original version

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

STA. Double regulating valves DN 15-50

2-port seat valves PN25 with externally threaded connections

Operating and installation instructions

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Dial Adjustment)

2-port and 3-port valves PN 16

Seated valves VRB 3, VRG 3

Pressure relief valve

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Instruction presentation Special valves

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Knob Adjustment)

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

differential pressure regulating valve - threaded

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

BTV. Internally threaded 2-way control valve. Flow characteristics. Function

BCV31 DN20 - Blowdown Control Valve

Pressure Relief Valve DHV 718

Automatic balancing valves

Overview of types. Technical data. Safety notes

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

STAP. Differential pressure controller DN 15-50

Pressure Reducing Valve DMV 750 set range: bar

Upgradable balancing valves USV

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

Modular valve block. Operating manual Series MVB 100/200. Version BA EN Print-No TR MA DE Rev001

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

STA. Double regulating valves DN 15-50

PV4 and PV6 Piston Valves

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

STAD. Balancing valves DN (MD60, MD61, MD62)

Model PIV UL/FM Post Indicator Valve. Maintenance and Operation Manual UL/FM Post Indicator Valve Configuration AWWA C515

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

EB EN. Type 44-0 B Steam Pressure Reducing Valve Type 44-1 B Pressure Reducing Valve. Translation of original instructions

1200B2 Series Service Regulators. Instruction Manual

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Type Type Differential Pressure Regulators (opening)

MZX. Three-Port Seat Valves SPECIFICIATIONS AND GUIDE TO SELECTION

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

Two-port valves, male threaded, PN25

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL M2

STAD-C. Balancing valve ENGINEERING ADVANTAGE

STAP. Differential pressure controller DN

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Brass Check Valve RDL

OPERATING INSTRUCTIONS

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

SCA Series Inverted Bucket Steam Traps

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

Contents. 1. General information BROEN BALLOMAX Steel Ball Valves Approvals Quality Management...2

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

lead water to the next level NEEDLE VALVES

Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device

BSA6T and BSA64T Stainless Steel Bellows Sealed Stop Valves Installation and Maintenance Instructions

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

Transcription:

ZETKAMA Sp. z o.o. ul. 3 Maja 12 PL 57-410 Ścinawka Średnia DIFREN PRESSURE REGULATING VALVE USER MANUAL Version: 1/2017 Fig. 223 Data: 01.01.2017 TABLE OF CONTENS 1. Product description 2. Requirements for maintenance staff 3. Transport and strorage 4. Function 5. Application 6. Installation 7. Operation 8. Maintenance and repair 9. Causesof operating disturbances and their elimination 10. Decommissioning 11. Terms of warranty 1. PRODUCT DESCRIPION figura 223 ends threaded form Y-type Drawing No. 1 Materials from which the valve is made contains tables 1. 1/6

Tables 1 body material H type 55,56,65,66 1 body CuZn36Pb2As 2 disc CuZn36Pb2As 3 seal of the disc EPDM 4 retaining ring CuZn36Pb2As 5 measuring nipples CuZn36Pb2As 6 o-ring EPDM 7 diaphragm EPDM + X5CrNi18-10 8 support SPETOBAR BAS 340 9 bonnet CuZn36Pb2As 10 o-ring EPDM 11 hand-wheel - scale polyamide 12 nut spring CuZn36Pb2As 13 hand-wheel polyamide 14 retaining ring A2 15 stem CuZn36Pb2As 16 spring X17CrNi16-2 max. temperature 120 DPRV valve are made in the following ranges difference pressure: P instal = 10 30 kpa for DN 15-25 P instal = 25 70 kpa for DN 15-25 P instal = 20 60 kpa for DN 32-50 P instal = 40 90 kpa for DN 32-50 Tmax : 120 C Tmin : - 10 C Valve s produced by ZETKAMA, including DPRV, have a permanent marking compliant with the requirements of PN- EN19. The marking facilitates technical identification and contains: Nominal diameter DN (mm), Nominal pressure PN (bar), Designation of the material of which the body and cover are made, Arrow indicating the direction of flow, manufacturer,. 2/6

2. REQUIREMENTS FOR MAINTENANCE STAFF The staff assigned to assembly, operating and maintenance shall be qualified to perform this work. During valve operation heat parts of the valve, e.g. body or cover parts could cause burn.if necessary the user should fit insulation shields and warning signs. 3. TRANSPORT AND STORAGE Transport and storage should be carried out at a temperature from -20 C to 65 C, and valves should be protected against external forces.valves must be stored free from contaminants and protected against the weather. In humid areas drying agent or heating should be applied to prevent the formation of condensation. The valves should be transported in a manner that does not damage the handwheel. 4. FUNCTION Differential pressure controller maintains a constant differential pressure adjustable at a given flow. The regulation is accurate and stable so that there is less risk of noise from control valves. Controls are mounted on pipes return. It is possible to shutting off the flowc by closing the regulator, using the dial item 13 - Turn the knob in the clockwise direction until closing. 5. APPLICATION heating refrigeration and air conditioning industrial water neutral fluids Working medium requires or prohibits the use of certain materials.the valves are designed for normal conditions of use. In the case that working conditions exceed these requirements, e.g. in the case of aggressive or abrasive factors, a user should make an inquiry to the manufacturer before ordering. Working pressure should be adjusted to the maximum temperature of the medium, as shown below. DPRV Fig. 223 Temperature[º C] Material PN -10 do 120 CuZn36Pb2As 16 16 bar The responsibility for correct selection of the valve is borne by designer. 6. INSTALATION At the assembly of DPRV valves, observe the following rules: - before an assembly evaluate if the valves were not damaged during transport or storage, and make sure that applied valves are suitable for working conditions and the media in the system, - remove caps if the DPRV valves are provided with them - check if the interior of valve is free of foreign matter, - protect valves during e.g. welding, against splinters and used plastics against excessive temperaturę 3/6 Pipeline, on which valves are mounted, should be arranged and mounted so the valve body is not transmitting bending moment and is not extended. - use compensators in order to reduce the impact of thermal expansion of pipeline - install the valve so that flow direction comply with an arrow placed on the body.

- correct operation of the valve requires suitably long straight sections: 5 x DN up and 2 x DN downstream - during pipeline painting valve. parts made of plastic and scale of the valve must be protected, - valves can be mounted in any position, recommend position of the valve is wheel down, - before starting the installation, especially after repairs, the pipeline should be flushed through with the fully opened valve, - installation of strainer before the valve increases certainty of its correct functioning - connect impulse pipe (pos. 1) between a balancing valve in the supply (item 2) and the feed opening of the diaphragm regulator (item 3) mounted on the return - vent the upper and lower part and impulse pipe by loosening (item. 3) until water flows - make a test the DPRV valve with cold water Balancing valve fig. 221 Supply Fig.221 P instal heating installation Return Fig.223 7. CONTROL AND SETTING Setting the DPRV with the presetting valves : 1. Fully open all balancing valves 2. Set all valves at the end receivers on the design flow. 3. Set the differential pressure using of hand-wheel - number of rotations is given in Table 2. 4. Measure the pressure difference Δpinstal - using the Balancing Measuring Device T550, connecting it to the measuring nipples in Fig.221, item. 2, and the measuring nipples item. 4 of DPRV. 5. If the flow rate on a balancing valve Fig.221 is different from the design value, reset ΔP instal to get on the valve in Fig.221 design value of flow rate. 4/6

Because the installation has of the inertia, wait a few minutes to read the measured values. Turn of hand wheel for DN 15-25 Turn of hand wheel for DN 32-50 10-30 kpa 25-70 kpa 20-60 kpa 40-90 kpa 10 0,0 Pinstal [kpa] 15 3,0 20 6,0 0,0 25 9,0 0,0 1,3 30 12,0 1,3 2,5 35 2,7 3,8 40 4,0 5,0 0,0 45 5,3 6,3 1,0 50 6,7 7,5 2,0 55 8,0 8,8 3,0 60 9,3 10,0 4,0 65 10,7 5,0 70 12,0 6,0 75 7,0 80 8,0 85 9,0 90 10,0 to ensure the safe operation of each valve and the regulator should be checked regularly. 8. MAINTENANCE AND REPAIR DPRV valves Fig.223 do not require any maintenance provided that they are used in accordance with their intended use Before taking up any maintenance actions, make sure that you have cut off the flow of medium in the pipe, the pressure was reduced to ambient pressure, medium was removed and the system was cooled down. all maintenance and repair work should be performed by qualified personnel using suitable tools and original spare parts. during the maintenance and repair work personal protection measures appropriate for the risk involved should be used, after removing the valve there is a need to replace the sealing, with which the valve is connected to the pipeline, each time when the cover is removed, clean the valve sealing surface and apply new gasket of the same type as previously used tightening the cover to the body must be made with the valve opened (plug in the upper position) - before reassembling the valve in the pipeline it is necessary to check valve operation and tightness of all connections. Tightness test should be carried out with water pressure of 1,5 x nominal press ure of the valve 9. CAUSES OF OPERATING DISTURBANCES AND THEIR ELIMINATION - When searching for the malfunctioning of the valve safety rules must be observed 5/6

DISTURBANCE POSSIBLE CAUSE HOW TO REMOVE No flow Low flow Valve closed The caps not remove Valve not sufficiently open Contaminated filter Clogged pipeline system Open the valve Remove the caps Open the valve Clean or replace the strainer Check the pipeline Leakage on the spindle Contaminated O-rings Replace the O-rings Leakage on the seat Demaged the seat or plugs ring Medium contaminated with solid objects Replace the valve.contact the supplier or manufacturer Clean the valve. Install the filter before the valve 10. DECOMMISSIONING After decommissioning and dismantling, valves must not be disposed of with household waste.the valves are made of materials that can be recycled.to do this, deliver them to a recycling point. 11. Terms of warranty ZETKAMA guarantees the quality with assurance for proper operation of its products, when installed in accordance with the instruction manual and the operation according to technical conditions and parameters described in the data sheets of ZETKAMA. The warranty period is 18 months from the date of installation, but not longer than 24 months from the date of sale. The warranty does not cover assembly of foreign parts and design changes made by the user as well as natural wear. You should inform ZETKAMA about hidden defects of the product immediately after detection. Complaint must be in writing. Address for correspondence ZETKAMA Sp. z o.o. ul. 3 Maja12 57-410 Ścinawka Średnia Telefon +48 74 86 52 100 Telefax +48 74 86 52 101 Internet: www.zetkama.pl 6/6